REPORT NUMBER: ITL62820 DATE: 08/13/09 CATALOG NUMBER

advertisement
THE LIGHT CENTER OF THE INDUSTRY SINCE 1955
PHONE: (303)442-1255
•
FAX: (303)449-5274
•
INDEPENDENT TESTING LABORATORIES, INC.
3386 LONGHORN ROAD, BOULDER, CO 80302 USA
E-MAIL: itl@itlboulder.com
REPORT NUMBER: ITL62820
•
WEBSITE: www.itlboulder.com
DATE: 08/13/09
CATALOG NUMBER: LED RD WL/5 OSI800 3000K
LUMINAIRE: FABRICATED METAL FRAME, LED OPTICAL ASSEMBLY WITH 12 LEDS,
FORMED SPECULAR METAL WALL WASH REFLECTOR WITH FABRICATED
DIFFUSE METAL REAR INSERT AND FROSTED CONVEX GLASS LINEAR
PRISMATIC LENS OVER UPPER APERTURE, PRISMS DOWN.
LAMP: ONE 14-WATT LED MODULE, OSRAM DLM800WF. MODULE CONSISTS OF:
CAST FINNED METAL HOUSING, FABRICATED WHITE REFLECTOR INSERT,
ONE WHITE CIRCUIT BOARD WITH 12 WHITE LIGHT EMITTING DIODES
(LEDS) EACH WITH CLEAR HEMISPHERICAL GLASS INTEGRAL LENS,
HOLOGRAPHIC FLAT PLASTIC LENS SECURED TO HOUSING WITH
FABRICATED WHITE PAINTED METAL RING CLIP.
MODULE AIMED 10-DEGREES UP FROM STRAIGHT
DOWN, LEDS TILTED 10-DEGREES FROM
VERTICAL BASE-UP POSITION.
TOTAL INPUT WATTS = 14.7 AT 120.0 VOLTS
MOUNTING: RECESSED
LED DRIVER: OSRAM OT17/120-277/700E
NOTE: DATA SHOWN IS ABSOLUTE FOR THE SAMPLE
PROVIDED AT RATED INPUT VOLTAGE
(120VAC, 60Hz) TO THE LED DRIVER.
LAMP INFORMATION PROVIDED BY CLIENT.
TEST PROCEDURE: IESNA LM-79-08
TEST DISTANCE = 25.25 FEET
CANDELA DISTRIBUTION
0.0 45.0 90.0 135.0 180.0
0
342
342
342
342
342
5
403
382
333
294
281
15
457
394
271
182
154
25
413
329
176
97
84
35
329
236
97
56
31
45
229
138
47
11
6
55
125
66
15
2
0
65
61
30
5
0
0
75
29
15
1
0
0
85
5
1
0
0
0
90
0
0
0
0
0
ZONAL LUMEN SUMMARY
ZONE
LUMENS
0- 30
210
0- 40
299
0- 60
393
0- 90
418
90-180
0
0-180
418
FLUX
32
81
98
89
61
33
16
8
1
%FIXT
50.2
71.5
93.9
100.0
0.0
100.0
EFFICACY = 28.4 Lm/W
CIE TYPE - DIRECT
PLANE
: 0-DEG 90-DEG 180-DEG
SPACING CRITERIA :
1.4
0.8
0.4
LUMINOUS DIAMETER:
5.125
LUMINANCE DATA IN CANDELA/SQ M
ANGLE AVERAGE AVERAGE AVERAGE
IN DEG
0-DEG 90-DEG 180-DEG
45 24334.
4994.
638.
55 16375.
1965.
0.
65 10845.
889.
0.
75
8419.
290.
0.
85
4311.
0.
0.
90˚
75˚
150
60˚
300
45˚
450
0˚
LEGEND:
0-deg:
90-deg:
180-deg:
15˚
Checked
R BEATTIE
Approved
R BERGIN
30˚
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.
THE LIGHT CENTER OF THE INDUSTRY SINCE 1955
PHONE: (303)442-1255
•
FAX: (303)449-5274
REPORT NUMBER: ITL62820
CANDELA DISTRIBUTION
0.0 22.5 45.0
0.0
342
342
342
2.5
375
371
363
5.0
403
395
382
7.5
427
417
392
10.0
444
431
400
12.5
454
440
400
15.0
457
440
394
17.5
454
434
383
20.0
444
424
368
22.5
430
408
348
25.0
413
391
329
27.5
393
370
307
30.0
374
348
283
32.5
352
327
260
35.0
329
304
236
37.5
307
280
211
40.0
282
254
186
42.5
256
228
161
45.0
229
201
138
47.5
201
174
117
50.0
173
149
98
52.5
148
126
81
55.0
125
106
66
57.5
104
88
54
60.0
88
74
44
62.5
73
61
36
65.0
61
51
30
67.5
51
42
25
70.0
43
36
21
72.5
36
30
18
75.0
29
25
15
77.5
22
19
11
80.0
16
13
7
82.5
10
8
4
85.0
5
4
1
87.5
1
0
0
90.0
0
0
0
•
INDEPENDENT TESTING LABORATORIES, INC.
3386 LONGHORN ROAD, BOULDER, CO 80302 USA
E-MAIL: itl@itlboulder.com
•
WEBSITE: www.itlboulder.com
DATE: 08/13/09
67.5
342
356
360
362
354
349
332
315
293
272
250
227
203
179
155
134
114
96
80
66
53
43
34
26
21
16
13
10
8
7
6
4
2
1
0
0
0
90.0 112.5 135.0 157.5 180.0
342
342
342
342
342
347
336
325
317
315
333
314
294
284
281
326
293
267
251
246
309
269
239
220
214
291
245
210
190
183
271
219
182
161
154
247
193
155
135
128
224
167
131
113
108
200
144
112
98
94
176
123
97
87
84
153
107
86
78
74
132
92
76
68
64
113
81
67
57
51
97
70
56
38
31
83
60
41
22
18
70
50
23
15
13
58
38
15
10
9
47
26
11
7
6
38
16
7
5
4
29
11
5
3
2
21
8
3
1
1
15
6
2
1
0
11
4
1
0
0
8
3
1
0
0
6
2
0
0
0
5
2
0
0
0
4
1
0
0
0
3
1
0
0
0
2
0
0
0
0
1
0
0
0
0
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.
THE LIGHT CENTER OF THE INDUSTRY SINCE 1955
PHONE: (303)442-1255
•
FAX: (303)449-5274
REPORT NUMBER: ITL62820
•
INDEPENDENT TESTING LABORATORIES, INC.
3386 LONGHORN ROAD, BOULDER, CO 80302 USA
E-MAIL: itl@itlboulder.com
•
WEBSITE: www.itlboulder.com
DATE: 08/13/09
ZONAL LUMEN SUMMARY
0- 5
8.
5- 10
24.
10- 15
36.
15- 20
44.
20- 25
48.
25- 30
49.
30- 35
47.
35- 40
41.
40- 45
34.
45- 50
27.
50- 55
19.
55- 60
14.
60- 65
10.
65- 70
7.
70- 75
5.
75- 80
3.
80- 85
1.
85- 90
0.
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.
THE LIGHT CENTER OF THE INDUSTRY SINCE 1955
PHONE: (303)442-1255
•
FAX: (303)449-5274
•
INDEPENDENT TESTING LABORATORIES, INC.
3386 LONGHORN ROAD, BOULDER, CO 80302 USA
E-MAIL: itl@itlboulder.com
•
REPORT NUMBER: ITL62820
WEBSITE: www.itlboulder.com
DATE: 08/13/09
COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD
EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20
RC
RW
80
70 50 30 10
70
70 50 30 10
50
50 30 10
30
50 30 10
10
50 30 10
0
1
2
3
4
5
6
7
8
9
10
119119119119
112109106103
105 99 94 90
98 90 84 79
92 82 76 70
86 76 69 63
81 70 63 58
76 65 58 53
72 60 53 48
68 56 49 45
64 53 46 41
117117117117
110107104101
103 97 92 88
96 89 83 78
90 81 75 70
84 75 68 63
79 69 62 57
74 64 57 52
70 60 53 48
66 56 49 45
63 52 46 41
111111111
102100 98
94 90 87
86 81 77
79 73 69
73 67 62
67 61 57
63 57 52
58 52 48
55 49 44
51 45 41
107107107
99 97 95
91 87 85
83 79 76
77 72 68
71 66 62
66 61 56
61 56 52
57 52 48
54 48 44
50 45 41
102102102
95 94 92
88 85 83
81 77 75
75 71 67
69 65 61
64 60 56
60 55 51
56 51 47
53 48 44
50 45 41
0
0
100
90
81
73
66
60
54
50
46
42
39
ALL CANDELA, LUMENS, LUMINANCE, AND VCP VALUES IN THIS REPORT ARE
BASED ON ABSOLUTE PHOTOMETRY. THE COEFFICIENT OF UTILIZATION VALUES
ARE BASED ON THE TOTAL ABSOLUTE LUMEN OUTPUT OF THIS LUMINAIRE SAMPLE.
NOTE:
THE ZONAL CAVITY CALCULATION TECHNIQUE IS ACCURATE WHEN
LUMINAIRES WITH SYMMETRIC CANDELA DISTRIBUTIONS ARE EMPLOYED
AND WHEN THE LUMINAIRES ARE LOCATED SYMMETRICALLY THROUGHOUT
THE ROOM. THIS UNIT HAS SPECIAL CHARACTERISTICS AND THEREFORE
THESE COEFFICIENTS SHOULD BE USED WITH CAUTION.
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.