OHW (908) 232 - 1232 AERIAL ELECTRIC CONDUCTORS NEW POLE OHW NEW POLE Garden State Underground Utility Locator Service NEW JERSEY CITY OF ESTELL MANOR PARTNER: GERALD S. BLACKMAN, AIA, PP, NCARB ASSOCIATE: STEVEN J. BOLOGNO, RA ATLANTIC COUNTY, ESTELL MANOR PARK MANSION VETERANS MUSEUM GERALD S. BLACKMAN, AIA, PP, NCARB N.J. LIC. No. A1 17113 SITE ELECTRICAL PLAN SCALE: 1" = 20'-0" 210 E. STREET ROAD TELE # (215)322-7711 SUITE 2D FAX # (215)322-7709 FEASTERVILLE, PA 19053 HOLSTEIN WHITE, INC. 1 CONSULTING ENGINEERS OHW EXISTING UTILITY POLE PRINCIPAL: DANIEL A. SHOUSKY AIA, PP, NCARB PRINCIPAL: PAUL A. KISS AIA, PP, NCARB ELBA-6 CALL BEFORE YOU DIG ! NEW JERSEY STATUTE 2C:17-5 OF 1979 REQUIRES (3) WORKING DAYS NOTICE FOR CONSTRUCTION PHASE AND (5) WORKING DAYS IN DESIGN STAGE -- STOP CALL FOUNDER: JOHN J. OLIVIERI (1956-1999) WP UNDERGROUND ELECTRIC CONDUCTORS PROPOSED 10,000 GAL. 8' DIA. x 31'-6 1/2" Long UNDERGROUND WATER STORAGE TANK FOR FIRE SUPPRESSION WATER WELL 17 WEST KNIGHT AVENUE, SUITE 200, COLLINGSWOOD, NEW JERSEY 08108 PHONE: (856) 854-0580 FAX: (856) 854-0993 Vestibule OHW OHW WELL PUMP, FIELD VERIFY TERMINATION LOCATION AND ELETRICAL CHARACTERISTICS PRIOR TO ROUGHPROPOSED -IN POTABLE ARCHITECTS AND PLANNERS www.olivieriarchitects.com PROPOSED 500 G.P.D. SEPTIC FIELD BSMT. ENT. OSK Design Partners P.A. OIL TANK EXISTING MANOR HOUSE THIS PLAN IS NOT VALID UNLESS A RAISED SEAL IS AFFIXED HERETO TANK OHW BRICK WALL ROUTE GENERATOR CONDUCTORS UNDERGROUND TO CRAWLSPACE SEE NOTE #11 HWAY IG H E T A T S Y E S NEW JER #50 OHW NATURAL GAS GENERATOR MOUNTED ON CONCRETE FOUNDATION, VERIFY FINAL LOCATION WITH OWNER AND ARCHITECT PRIOR TO ROUGH-IN PLAN IS DIAGRAMMATIC ONLY. VERIFY EXACT LOCATIONS OF ALL EQUIPMENT AND SITE WORK WITH OWNER, ARCHITECT, AND CIVIL ENGINEER PRIOR TO COMMENCING WORK.! ! CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF UNDERGROUND SERVICES WITH OTHER CONTRACTORS AND UTILITY COMPANIES.! ! EXACT ROUTING AND TERMINATION POINTS OF UNDERGROUND SERVICES SHALL BE VERIFIED WITH THE UTILITY COMPANY AND OTHER CONTRACTORS.! ! IN ADDITION TO THE LENGTH SHOWN, THE CONTRACTOR SHALL PROVIDE A UNIT PRICE PER 25'-0" OF RUN FOR SECONDARY ELECTRIC SERVICE CONDUITS, RELATED TRENCHING, AND BACKFILL.! ! COORDINATE FINAL INTERCONNECTIONS TO EACH UTILITY COMPANY, PROVIDE ALL MATERIALS AND LABOR REQUIRED FOR SERVICE CONNECTIONS IN ACCORDANCE WITH EACH UTILITY (POWER AND COMMUNICATIONS) COMPANY SERVICE STANDARDS. ! ! POSITION OUTDOOR FIXTURES, TYPE 'M1' AT NIGHT TO ILLUMINATE TARGET AREA OF RANGE. FIXTURE AIMING SHALL BE TO SATISFACTION OF OWNER.! ! UNLESS OTHERWISE NOTED, UNDERGROUND ELECTRICAL AND COMMUNICATIONS CONDUITS SHALL BE 24" MINIMUM BELOW GRADE. UNDERGROUND CONDUITS SHALL BE SCHEDULE 40 PVC.! ! PROVIDE, IN TRENCH CONTAINING ELECTRIC AND COMMUNICATION DUCT SYSTEMS, AN UNDERGROUND UTILITY MARKING TAPE. TAPE SHALL BE BURIED 1 FOOT BELOW GRADE AND RUN CONTINUOUS THE ENTIRE LENGTH OF DUCT TRENCH. TAPE SHALL BE BRIGHTLY COLORED RED POLYETHYLENE LONG LIFE TYPE WITH PRINTED WARNING TO READ "CAUTION, BURIED ELECTRIC LINE BELOW". ! ! PROVIDE ALL REQUIRED EXCAVATION TRENCHING, BACKFILLING, COMPACTING IN ACCORD WITH THIS DIVISION. ! ! PROVIDE APPROVED GROUNDING CONDUCTOR IN ALL CONDUIT.! ! IN ADDITION TO UNDERGROUND POWER CONDUITS REQUIRED PER GENERATOR MANUFACTURER. PROVIDE THE FOLLOWING UNDERGROUND CONDUITS BETWEEN GENERATOR ENCLOSURE AND BUILDING; (1) 1” CONDUIT FOR BLOCK HEATER AND BATTERY CHARGER CIRCUITS, (1) 1” CONDUIT FOR ANNUNCIATOR CABLES AND ATS GENERATOR CONTROL WIRING. SITE ELECTRICAL PLAN SITE ELECTRICAL NOTES 1.! ! ! ! ! 2.! ! ! ! ! 3.! ! ! ! ! 4.! ! ! ! ! ! 5.! ! ! ! ! ! ! 6.! ! ! ! ! 7.! ! ! ! ! ! 8.! ! ! ! ! ! ! ! ! ! 9.! ! ! ! 10.! ! ! 11. Jeffrey E. Holstein, P.E. License No. NJ GE46443 Authorization NO; 2GA28143700 REVISIONS: ADDEDUM #1 7-1-2014 DATE: 7-1-2014 SCALE: AS NOTED DRAWN BY: JAC CHK'D BY: ISSUED TO ATLANTIC COUNTY FOR REVIEW 1 06-21-2013 DRAWING ISSUE No. DATE JEH PROJECT No. DA09057 E0.1 UH 1 D C C PE FS FS FS C C C TS TS TS FIRE PUMP CONTROL PANEL SHALL! BE INTERCONNECTED TO THE FIRE! ALARM SYSTEM FOR THE FOLLOWING:! PUMP RUNNING, PHASE LOSS, AND PHASE REVERSAL 53 23 D D PE UH 1 PE BASEMENT WATER SOFTENER 001 61 49 D TELECOM EQUIPMENT; PROVIDE! 3/4" X 8' X 4' PLYWOOD BACKBOARD PE NEW JERSEY CITY OF ESTELL MANOR ESTELL MANOR PARK MANSION VETERANS MUSEUM ATLANTIC COUNTY, PARTNER: GERALD S. BLACKMAN, AIA, PP, NCARB ASSOCIATE: STEVEN J. BOLOGNO, RA PRINCIPAL: DANIEL A. SHOUSKY AIA, PP, NCARB PRINCIPAL: PAUL A. KISS AIA, PP, NCARB C 002 003 FOUNDER: JOHN J. OLIVIERI (1956-1999) BASEMENT CRAWLSPACE 17 WEST KNIGHT AVENUE, SUITE 200, COLLINGSWOOD, NEW JERSEY 08108 PHONE: (856) 854-0580 FAX: (856) 854-0993 VERIFY QUANTITY AND LOCATIONS! OF FLOW AND TAMPER SWITCHES! WITH FIRE SUPPRESSION VENDOR ARCHITECTS AND PLANNERS www.olivieriarchitects.com PE PE OSK Design Partners P.A. 004 D FIELD VERIFY LOCATION OF ALL WIRING DEVICES WITH ARCHITECT PRIOR TO ROUGH-IN.! ! COORDINATE INSTALLATION OF HVAC EQUIPMENT WITH MECHANICAL CONTRACTOR. INSTALL AND WIRE DISCONNECT SWITCHES FURNISHED BY MECHANICAL CONTRACTOR.! ! UNLESS OTHERWISE NOTED, ALL POWER SHALL BE CIRCUITED TO PANEL 'ABB'. THIS PLAN IS NOT VALID UNLESS A RAISED SEAL IS AFFIXED HERETO CRAWLSPACE D BASEMENT - POWER PLAN DRAWING NOTES 1.! ! ! 2.! ! ! ! ! 3. GERALD S. BLACKMAN, AIA, PP, NCARB N.J. LIC. No. A1 17113 UC CRAWLSPACE 005 PROVIDE (2) 2" PVC C. TO TELECOM UTILITY TERMINATION POINT, COORDINATE LOCATION, ROUTING, AND REQUIREMENTS WITH OWNERS PHONE/DATA DESIGNER 210 E. STREET ROAD TELE # (215)322-7711 SUITE 2D FAX # (215)322-7709 FEASTERVILLE, PA 19053 HOLSTEIN WHITE, INC. F 23 CONSULTING ENGINEERS F F 21 Jeffrey E. Holstein, P.E. License No. NJ GE46443 Authorization NO; 2GA28143700 REVISIONS: 1 BASEMENT - ! POWER PLAN SCALE: 1/4" = 1'-0" DATE: 7-1-2014 SCALE: AS NOTED DRAWN BY: JAC CHK'D BY: ISSUED TO ATLANTIC COUNTY FOR REVIEW 1 06-21-2013 DRAWING ISSUE No. DATE JEH PROJECT No. DA09057 E1.0 F5 E ELBA-7 ELCU E ELBA-7 F5 NEW JERSEY CITY OF ESTELL MANOR PARTNER: GERALD S. BLACKMAN, AIA, PP, NCARB ASSOCIATE: STEVEN J. BOLOGNO, RA ATLANTIC COUNTY, ESTELL MANOR PARK MANSION VETERANS MUSEUM ARCHITECTS AND PLANNERS www.olivieriarchitects.com PRINCIPAL: DANIEL A. SHOUSKY AIA, PP, NCARB PRINCIPAL: PAUL A. KISS AIA, PP, NCARB ELCU 003 FOUNDER: JOHN J. OLIVIERI (1956-1999) 002 CRAWLSPACE 17 WEST KNIGHT AVENUE, SUITE 200, COLLINGSWOOD, NEW JERSEY 08108 PHONE: (856) 854-0580 FAX: (856) 854-0993 BASEMENT OSK Design Partners P.A. 004 FIELD VERIFY LOCATION OF ALL WIRING DEVICES WITH ARCHITECT PRIOR TO ROUGH-IN.! ! FIELD VERIFY EXACT LOCATIONS OF ALL LIGHTING FIXTURES WITH ARCHITECT PRIOR TO ROUGH-IN.! ! UNLESS OTHERWISE NOTED ALL LIGHTING SHALL BE CIRCUITED TO PANEL 'ABB'.! ! EMERGENCY LIGHTING AND EXIT SIGNS SHALL BE CONNECTED TO LINE SIDE OF LOCAL LIGHTING CONTROL.! THIS PLAN IS NOT VALID UNLESS A RAISED SEAL IS AFFIXED HERETO CRAWLSPACE BASEMENT - LIGHTING PLAN DRAWING NOTES 1.! ! ! 2.! !! ! 3.! ! ! 4. GERALD S. BLACKMAN, AIA, PP, NCARB N.J. LIC. No. A1 17113 CRAWLSPACE 005 CONSULTING ENGINEERS HOLSTEIN WHITE, INC. 001 210 E. STREET ROAD TELE # (215)322-7711 SUITE 2D FAX # (215)322-7709 FEASTERVILLE, PA 19053 BASEMENT Jeffrey E. Holstein, P.E. License No. NJ GE46443 Authorization NO; 2GA28143700 REVISIONS: 1 BASEMENT - ! LIGHTING PLAN SCALE: 1/4" = 1'-0" DATE: 7-1-2014 SCALE: AS NOTED DRAWN BY: JAC CHK'D BY: ISSUED TO ATLANTIC COUNTY FOR REVIEW 1 06-21-2013 DRAWING ISSUE No. DATE JEH PROJECT No. DA09057 E1.1 24 WP 10 20 57 32 28 WP WP WP WP WP NEW JERSEY CITY OF ESTELL MANOR ATLANTIC COUNTY, CU 5 CU 4 CU 3 FIELD VERIFY LOCATION OF ALL WIRING DEVICES WITH ARCHITECT PRIOR TO ROUGH-IN.! ! COORDINATE INSTALLATION OF HVAC EQUIPMENT WITH MECHANICAL CONTRACTOR. INSTALL AND WIRE DISCONNECT SWITCHES FURNISHED BY MECHANICAL CONTRACTOR.! ! UNLESS OTHERWISE NOTED, ALL POWER SHALL BE CIRCUITED TO PANEL 'ABB'. ESTELL MANOR PARK MANSION VETERANS MUSEUM CU 2 CU 1 FIRST FLOOR - POWER PLAN DRAWING NOTES 1.! ! ! 2.! ! ! ! ! 3. ELBA-5 10 F E E ELBA-5 PARK E ELBA-5 ADMINISTRATION 110 25 25 27 FIRE ALARM REMOTE ANNUNCIATOR 27 F 29 F 29 D F ACCESSIBLE ENTRY F F F VESTIBULE 29 29 TYPE 'A' PE ELBA-5 107 ENTRY HALL D PE E D STAIR #1 PE 37 CLOSET 29 AHU 1 JAN. S1-1 102D 29 E 29 MECHANICAL ELBA-5 D 112 F F 31 FIRE ALARM CONTROL PANEL ELBA-2 33 39 D 47 + KITCHENETTE D F F MEETING ROOM D TYPE 'A' PE 37 105 PE 12 111 B1 S D D HAND DRYER PE 113 D 114 17 FU_COLD FIXT_CODE FU_TOTAL FU_WASTE FU_HOT 12 D TOILET ROOM ROOM PE 57 17 D SM 115 C C F 10 INTERCONNECT TO ! LIGHTING CONTROL WP N.J. LIC. No. A1 17113 ELEV. AH 5 EQUIP. SM C PANEL 'ABB' GERALD S. BLACKMAN, AIA, PP, NCARB 4 F PE SM 45 PANEL ELBA F ELBA-1 ELBA-1 2 + 12 + TOILET 43 33 12 PE ATS-1 STORAGE F E1-1 F 2 EF 1 12 F F HAND DRYER 33 D D F AREA 33 104 VAPORTIGHT FLUORESCENT! PIT LIGHT ELEVATOR 108 D PANEL 'ABA' F TYPE 'A' 33 DINING / DISPLAY 18 6 CLOSET 109 31 EXHIBIT AHU 2 LOCATED IN PIT 41 REF M F PE FU_COLD 31 FU_TOTAL 31 FU_HOT 33 33 FIXT_CODE 8 16 ROOM PE F FU_WASTE WP ELBA-5 PE F F D 103 6 SLEEVE SERVICE ENTRANCE CONDUCTORS THROUGH WALL EF 1 M ELEVATOR POWER 10 WP ELEVATOR CAB LIGHTING CT CABINET AND UTILITY METERING UE TYPE 'A' EXHIBIT 35 D TYPE 'A' PE AREA 35 INTERCONNECT TO! LIGHTING CONTROL 106 PARTNER: GERALD S. BLACKMAN, AIA, PP, NCARB ASSOCIATE: STEVEN J. BOLOGNO, RA WP 27 PRINCIPAL: DANIEL A. SHOUSKY AIA, PP, NCARB PRINCIPAL: PAUL A. KISS AIA, PP, NCARB PE 27 CONSULTING ENGINEERS D 101 25 210 E. STREET ROAD TELE # (215)322-7711 SUITE 2D FAX # (215)322-7709 FEASTERVILLE, PA 19053 25 F F HOLSTEIN WHITE, INC. TYPE 'A' THIS PLAN IS NOT VALID UNLESS A RAISED SEAL IS AFFIXED HERETO MEETING ROOM PE FOUNDER: JOHN J. OLIVIERI (1956-1999) GENERATOR BACKED CIRCUIT D TYPE 'A' ARCHITECTS AND PLANNERS www.olivieriarchitects.com 100 OSK Design Partners P.A. ENTRY RAMP 27 17 WEST KNIGHT AVENUE, SUITE 200, COLLINGSWOOD, NEW JERSEY 08108 PHONE: (856) 854-0580 FAX: (856) 854-0993 3 #12 & 1 #12G., 3/4"C. to AHU-5 27 25 TO UTILITY COMPANY TRANSFORMER 35 Jeffrey E. Holstein, P.E. License No. NJ GE46443 35 Authorization NO; 2GA28143700 35 REVISIONS: 1 FIRST FLOOR - ! POWER PLAN SCALE: 1/4" = 1'-0" DATE: 7-1-2014 SCALE: AS NOTED DRAWN BY: JAC CHK'D BY: ISSUED TO ATLANTIC COUNTY FOR REVIEW 1 06-21-2013 DRAWING ISSUE No. DATE JEH PROJECT No. DA09057 E2.0 1 F6 3 F6 3 F6 MEETING ROOM 101 ELBA-7 7 F8 7 F8 ELCU E 1 F2 F2 1 3 F7 ELCU ELBA-7 7 F7 ELCU ELCU R E R ELBA-3 7 R 19 ELCU F2 3 F2 3 ELBA-7 F2 F8 3 7 3 3 ELCU E1 3 ELBA-3 5 5 F6 5 F6 5 F6 F6 R ENTRY HALL ELCU E1 R E 5 ELBA-7 F3 F6 3 3 F1 19 R F10 F1 F2 LIGHTING REACTIVATION! SWITCH #1 5 SD F6 5 ELBA-3 E F1 E 17 ELBA-7 E2 E1 E ELCU ELCU 107 ELCU 103 R E VESTIBULE 7 ELBA-7 F1 110 E F2 E CEMETERY OFFICE 1 E F9 ELBA-3 F1 ELCU ELBA-7 1 F3 R E F3 R 5 3 F1 JAN. CLOS. 102 7 F8 E1 ELBA-7 9 19 ELCU 9 F2 F2 F1 F2 11 11 ELBA-7 ELCU R 17 R E E 7 F9 17 E1 F2 11 CLOSET 17 F5 108 R F2 17 F1 F5 F3 DINING / DISPLAY MEETING ROOM EXHIBIT AREA 9 104 9 11 KITCHENETTE F2 ELCU 105 F7 E1 F2 11 STORAGE 109 R 19 111 E 17 ELBA-7 F1 F10 3 F7 11 F2 THIS PLAN IS NOT VALID UNLESS A RAISED SEAL IS AFFIXED HERETO 3 NEW JERSEY CITY OF ESTELL MANOR ESTELL MANOR PARK MANSION VETERANS MUSEUM ATLANTIC COUNTY, PARTNER: GERALD S. BLACKMAN, AIA, PP, NCARB ASSOCIATE: STEVEN J. BOLOGNO, RA F6 PRINCIPAL: DANIEL A. SHOUSKY AIA, PP, NCARB PRINCIPAL: PAUL A. KISS AIA, PP, NCARB 1 FOUNDER: JOHN J. OLIVIERI (1956-1999) F9 17 WEST KNIGHT AVENUE, SUITE 200, COLLINGSWOOD, NEW JERSEY 08108 PHONE: (856) 854-0580 FAX: (856) 854-0993 FIRST FLOOR - LIGHTING PLAN 19 ARCHITECTS AND PLANNERS www.olivieriarchitects.com FIELD VERIFY LOCATION OF ALL WIRING DEVICES WITH ARCHITECT PRIOR TO ROUGH-IN.! ! FIELD VERIFY EXACT LOCATIONS OF ALL LIGHTING FIXTURES WITH ARCHITECT PRIOR TO ROUGH-IN.! ! UNLESS OTHERWISE NOTED ALL LIGHTING SHALL BE CIRCUITED TO PANEL 'XIX'.! ! EMERGENCY LIGHTING AND EXIT SIGNS SHALL BE CONNECTED TO LINE SIDE OF LOCAL LIGHTING CONTROL. OSK Design Partners P.A. DRAWING NOTES 1.! ! ! 2.! ! ! ! ! 3.! ! ! 4.! ! ! 5.! ! ! 6.! ! ! ! 7. GERALD S. BLACKMAN, AIA, PP, NCARB N.J. LIC. No. A1 17113 ELCU 11 F2 R E F1 F2 F2 F9 ELCU TOILET ROOM 113 9 17 ELBA-7 TOILET17 ROOM ELCU F5 R E F1 E 114 F5 FIXT_CODE FU_TOTAL FU_WASTE FU_HOT FU_COLD E3 115 ELBA-1 FIXT_CODE FU_TOTAL FU_WASTE FU_COLD FU_HOT ELEV. EQUIP. ELCU E1 E1 E 19 F11 (TYP) F8 19 F8 19 ELBA-7 F8 E3 13 13 T1 T1 F11 (TYP) ELCU ELBA-7 13 F11 (TYP) 19 ELCU EXHIBIT AREA R 13 E F1 F9 ELBA-7 13 CONSULTING ENGINEERS 9 ELBA-7 17 11 F6 F11 R (TYP) 15 E 210 E. STREET ROAD TELE # (215)322-7711 SUITE 2D FAX # (215)322-7709 FEASTERVILLE, PA 19053 9 F6 HOLSTEIN WHITE, INC. 19 F1 106 T2 T2 15 19 T1 15 F11 F11 (TYP) (TYP) T1 Jeffrey E. Holstein, P.E. License No. NJ GE46443 Authorization NO; 2GA28143700 F8 19 F9 19 F8 F9 19 REVISIONS: 1 FIRST FLOOR - ! LIGHTING PLAN SCALE: 1/4" = 1'-0" DATE: 7-1-2014 SCALE: AS NOTED DRAWN BY: JAC CHK'D BY: ISSUED TO ATLANTIC COUNTY FOR REVIEW 1 06-21-2013 DRAWING ISSUE No. DATE JEH PROJECT No. DA09057 E2.1 D 13 23 PE 23 201 D 11 13 13 PE TYPE 'A' 23 F F 23 F 15 15 23 15 F F F F F F VESTIBULE HALL STAIR #1 200D 202 S1-2 EXHIBIT AREA/ WORK ROOM PE 206 STAIR #1 S1-1 PANEL 'A2A' 15 WP F 8 23 F F 17 D 21 25 PE TYPE 'A' CLASSROOM/ D MEETING ROOM PE 25 CLOSET 21 205A ELEVATOR 203 D TYPE 'A' PE D D PE 17 17 25 F D EF 1 17 MEETING ROOM 19 PE E1-2 NEW JERSEY CITY OF ESTELL MANOR ATLANTIC COUNTY, ESTELL MANOR PARK MANSION VETERANS MUSEUM N.J. LIC. No. A1 17113 205 TOILET HAND DRYER ROOM 5 17 CLASSROOM/ 21 + 17 PE GERALD S. BLACKMAN, AIA, PP, NCARB SM 209 35 FD 21 FIXT_CODE FU_TOTAL FU_WASTE FU_HOT FU_COLD 21 INTERCONNECT TO LIGHTING CONTROL CONSULTING ENGINEERS PE D PARTNER: GERALD S. BLACKMAN, AIA, PP, NCARB ASSOCIATE: STEVEN J. BOLOGNO, RA 13 PRINCIPAL: DANIEL A. SHOUSKY AIA, PP, NCARB PRINCIPAL: PAUL A. KISS AIA, PP, NCARB 11 210 E. STREET ROAD TELE # (215)322-7711 SUITE 2D FAX # (215)322-7709 FEASTERVILLE, PA 19053 11 EXHIBIT AREA FOUNDER: JOHN J. OLIVIERI (1956-1999) TYPE 'A' CLASSROOM/ EXHIBIT AREA 13 204 PE CLASSROOM/ HOLSTEIN WHITE, INC. D TYPE 'A' 11 THIS PLAN IS NOT VALID UNLESS A RAISED SEAL IS AFFIXED HERETO 13 17 WEST KNIGHT AVENUE, SUITE 200, COLLINGSWOOD, NEW JERSEY 08108 PHONE: (856) 854-0580 FAX: (856) 854-0993 SECOND FLOOR - POWER PLAN 11 11 ARCHITECTS AND PLANNERS www.olivieriarchitects.com FIELD VERIFY LOCATION OF ALL WIRING DEVICES WITH ARCHITECT PRIOR TO ROUGH-IN.! ! COORDINATE INSTALLATION OF HVAC EQUIPMENT WITH MECHANICAL CONTRACTOR. INSTALL AND WIRE DISCONNECT SWITCHES FURNISHED BY MECHANICAL CONTRACTOR.! ! FIELD VERIFY EXACT LOCATIONS OF ALL LIGHTING FIXTURES WITH ARCHITECT PRIOR TO ROUGH-IN.! ! UNLESS OTHERWISE NOTED, ALL POWER SHALL BE CIRCUITED TO PANEL 'A2A'. OSK Design Partners P.A. DRAWING NOTES 1.! ! ! 2.! ! ! ! ! 3.! ! ! 4. Jeffrey E. Holstein, P.E. License No. NJ GE46443 Authorization NO; 2GA28143700 REVISIONS: 1 SECOND FLOOR - ! POWER PLAN SCALE: 1/4" = 1'-0" DATE: 7-1-2014 SCALE: AS NOTED DRAWN BY: JAC CHK'D BY: ISSUED TO ATLANTIC COUNTY FOR REVIEW 1 06-21-2013 DRAWING ISSUE No. DATE JEH PROJECT No. DA09057 E3.0 R 1 R 1 F1 F1 F1 1 R 1 R F1 1 R F1 R F1 7 7 F1 R 3 3 202 ELBA-9 3 ELCU E1 R E R E WORK ROOM HALL R 3 ELCU R 7 ELBA-9 7 R F1 F1 ELCU R E E F1 F1 3 ELBA-9 3 3 F3 F1 ELBA-9 3 206 R E 3 3 E1 E1 F1 3 200ELCU ELCU F1 3 VESTIBULE ABB-7 ELBA-9 R F1 F3 R 7 R F1 ABB-7 R F3 R F1 F1 F1 R E 5 F1 ELBA-9 CLOSET 205A MECHANICAL ROOM 5 5 ELCU R R R F1 F1 208 ELCU R 7 207 205 209 5 R R 5 R F1 5 R F1 5 5 F1 7 F1 ELBA-9 CORRIDOR OFFICE TOILET ROOM R E F1 OFFICE 203 3 5 5 5 R 7 F1 ELEVATOR E1-2 NEW JERSEY CITY OF ESTELL MANOR ATLANTIC COUNTY, PARTNER: GERALD S. BLACKMAN, AIA, PP, NCARB ASSOCIATE: STEVEN J. BOLOGNO, RA F1 OFFICE 204 1 R R 3 R F1 OFFICE 201 ABB-7 1 1 R F1 PRINCIPAL: DANIEL A. SHOUSKY AIA, PP, NCARB PRINCIPAL: PAUL A. KISS AIA, PP, NCARB F1 FOUNDER: JOHN J. OLIVIERI (1956-1999) 1 R 3 R F1 17 WEST KNIGHT AVENUE, SUITE 200, COLLINGSWOOD, NEW JERSEY 08108 PHONE: (856) 854-0580 FAX: (856) 854-0993 1 1 R THIS PLAN IS NOT VALID UNLESS A RAISED SEAL IS AFFIXED HERETO 1 F10 ESTELL MANOR PARK MANSION VETERANS MUSEUM SECOND FLOOR - LIGHTING PLAN 37 F10 ARCHITECTS AND PLANNERS www.olivieriarchitects.com 37 FIELD VERIFY LOCATION OF ALL WIRING DEVICES WITH ARCHITECT PRIOR TO ROUGH-IN.! ! FIELD VERIFY EXACT LOCATIONS OF ALL LIGHTING FIXTURES WITH ARCHITECT PRIOR TO ROUGH-IN.! ! UNLESS OTHERWISE NOTED ALL LIGHTING SHALL BE CIRCUITED TO PANEL 'A2A'.! ! EMERGENCY LIGHTING AND EXIT SIGNS SHALL BE CONNECTED TO LINE SIDE OF LOCAL LIGHTING CONTROL. OSK Design Partners P.A. DRAWING NOTES 1.! ! ! 2.! ! ! 3.! ! ! 4. GERALD S. BLACKMAN, AIA, PP, NCARB N.J. LIC. No. A1 17113 5 R F1 F1 R FD FIXT_CODE FU_TOTAL FU_WASTE FU_HOT CONSULTING ENGINEERS HOLSTEIN WHITE, INC. FU_COLD 210 E. STREET ROAD TELE # (215)322-7711 SUITE 2D FAX # (215)322-7709 FEASTERVILLE, PA 19053 F1 Jeffrey E. Holstein, P.E. License No. NJ GE46443 Authorization NO; 2GA28143700 REVISIONS: 1 SECOND FLOOR - ! LIGHTING PLAN SCALE: 1/4" = 1'-0" DATE: 7-1-2014 SCALE: AS NOTED DRAWN BY: JAC CHK'D BY: ISSUED TO ATLANTIC COUNTY FOR REVIEW 1 06-21-2013 DRAWING ISSUE No. DATE JEH PROJECT No. DA09057 E3.1 27 F 27 31 39 29 F F D D F D F F ATTIC ATTIC 300 F F D ATTIC 301 F ATTIC 307 D D 306 LOCATED TOP! OF STAIRS F F 27 D D D F D F STAIR #1 D F 39 S1-2 F F 39 29 AHU 4 27 ATTIC D 27 33 F 29 305 D ATTIC D F D F 303 D F TOP OF SHAFT WITHIN 2' OF SPRINKLER HEAD PE NEW JERSEY CITY OF ESTELL MANOR ATLANTIC COUNTY, ESTELL MANOR PARK MANSION VETERANS MUSEUM THIRD FLOOR - POWER PLAN N.J. LIC. No. A1 17113 ATTIC F 304 HOLSTEIN WHITE, INC. D D 29 D F 29 39 F GERALD S. BLACKMAN, AIA, PP, NCARB CONSULTING ENGINEERS D 27 210 E. STREET ROAD TELE # (215)322-7711 SUITE 2D FAX # (215)322-7709 FEASTERVILLE, PA 19053 AHU 3 PARTNER: GERALD S. BLACKMAN, AIA, PP, NCARB ASSOCIATE: STEVEN J. BOLOGNO, RA F F PRINCIPAL: DANIEL A. SHOUSKY AIA, PP, NCARB PRINCIPAL: PAUL A. KISS AIA, PP, NCARB D D FOUNDER: JOHN J. OLIVIERI (1956-1999) 309 17 WEST KNIGHT AVENUE, SUITE 200, COLLINGSWOOD, NEW JERSEY 08108 PHONE: (856) 854-0580 FAX: (856) 854-0993 ATTIC 308 ARCHITECTS AND PLANNERS www.olivieriarchitects.com ATTIC F THIS PLAN IS NOT VALID UNLESS A RAISED SEAL IS AFFIXED HERETO D FIELD VERIFY LOCATION OF ALL WIRING DEVICES WITH ARCHITECT PRIOR TO ROUGH-IN.! ! COORDINATE INSTALLATION OF HVAC EQUIPMENT WITH MECHANICAL CONTRACTOR. INSTALL AND WIRE DISCONNECT SWITCHES FURNISHED BY MECHANICAL CONTRACTOR.! ! UNLESS OTHERWISE NOTED, ALL POWER SHALL BE CIRCUITED TO PANEL 'A2A'. OSK Design Partners P.A. DRAWING NOTES 1.! ! ! 2.! ! ! ! ! 3. Jeffrey E. Holstein, P.E. License No. NJ GE46443 Authorization NO; 2GA28143700 REVISIONS: 1 THIRD FLOOR - ! POWER PLAN SCALE: 1/4" = 1'-0" DATE: 7-1-2014 SCALE: AS NOTED DRAWN BY: JAC CHK'D BY: ISSUED TO ATLANTIC COUNTY FOR REVIEW 1 06-21-2013 DRAWING ISSUE No. DATE JEH PROJECT No. DA09057 E4.0 F1 ATTIC ATTIC ATTIC 307 306 R 9 F1 ELCU E6 ATTIC 9 300 R F1 ELBA-9 9 9 ELBA-9 R E F1 301 9 R F1 ELCU R E F1 9 R F1 E1 E5 9 R ATTIC ELCU R E 9 ELBA-9 F1 ATTIC 305 F1 302 9 R 9 F1 R ATTICF1 303 LIGHTING REACTIVATION! SWITCH #2 R 9 F1 9 R F1 NEW JERSEY CITY OF ESTELL MANOR ESTELL MANOR PARK MANSION VETERANS MUSEUM THIRD FLOOR - LIGHTING PLAN ATLANTIC COUNTY, PARTNER: GERALD S. BLACKMAN, AIA, PP, NCARB ASSOCIATE: STEVEN J. BOLOGNO, RA R E ELBA-9 9 PRINCIPAL: DANIEL A. SHOUSKY AIA, PP, NCARB PRINCIPAL: PAUL A. KISS AIA, PP, NCARB F1 ELCU FOUNDER: JOHN J. OLIVIERI (1956-1999) 9 R 17 WEST KNIGHT AVENUE, SUITE 200, COLLINGSWOOD, NEW JERSEY 08108 PHONE: (856) 854-0580 FAX: (856) 854-0993 309 F1 ARCHITECTS AND PLANNERS www.olivieriarchitects.com ATTIC 308 R THIS PLAN IS NOT VALID UNLESS A RAISED SEAL IS AFFIXED HERETO ATTIC 9 FIELD VERIFY LOCATION OF ALL WIRING DEVICES WITH ARCHITECT PRIOR TO ROUGH-IN.! ! FIELD VERIFY EXACT LOCATIONS OF ALL LIGHTING FIXTURES WITH ARCHITECT PRIOR TO ROUGH-IN.! ! UNLESS OTHERWISE NOTED ALL LIGHTING SHALL BE CIRCUITED TO PANEL 'A2A'.! ! EMERGENCY LIGHTING AND EXIT SIGNS SHALL BE CONNECTED TO LINE SIDE OF LOCAL LIGHTING CONTROL. OSK Design Partners P.A. DRAWING NOTES 1.! ! ! 2.! ! ! 3.! ! ! 4. GERALD S. BLACKMAN, AIA, PP, NCARB N.J. LIC. No. A1 17113 ATTIC R CONSULTING ENGINEERS 210 E. STREET ROAD TELE # (215)322-7711 SUITE 2D FAX # (215)322-7709 FEASTERVILLE, PA 19053 304 F1 HOLSTEIN WHITE, INC. 9 Jeffrey E. Holstein, P.E. License No. NJ GE46443 Authorization NO; 2GA28143700 REVISIONS: 1 THIRD FLOOR - ! LIGHTING PLAN SCALE: 1/4" = 1'-0" DATE: 7-1-2014 SCALE: AS NOTED DRAWN BY: JAC CHK'D BY: ISSUED TO ATLANTIC COUNTY FOR REVIEW 1 06-21-2013 DRAWING ISSUE No. DATE JEH PROJECT No. DA09057 E4.1 Emergency Neutral (WHITE 18AWG) Top of Highest Electrical Safety Disconnect Switches, Magnetic Motor Starters and Contactors 4'-6" Wall Mounted Telephones and Pay Stations (3'-6" at Handicap Locations) 3'-6" Normal Power Sense (BLACK 18AWG) Emergency Power In (BLACK 12AWG) Fire Alarm Pull Stations 3'-4" Wall Mounted Electrical Device Lighting Switches 2'-0" Electrical Receptacles in Mechanical Spaces, Electrical and Elevator Rooms 1'-6" Cut jumper loop to use with Normally Closed -Test Switch -Fire Alarm Panel -Security Panel -Other NORMAL POWER EMAERGENCY POWER PUSH TO TEST REMOTE ACTIVATION CIR.# Electrical Receptacles, Television Outlets, Telephone Outlets, and Computer Outlets 0'-0" Finished Floor Mounting Heights to center of outlets unless otherwise noted. In masonry construction the mounting heights shall be used for! reference to the nearest block or brick coursing. ! The above mounting heights shall be adhered to unless specifically noted or detailed on the Architectural drawings or specifications. ELECTRICAL SYMBOLS Emergency Line 4-600MCM & 1# 1/0G, 4"C. 400AF! 400AT N SERVICE ENTRANCE RATED 225AF! 225AT PANEL ABA Emergency Neutral Electrical Panel D 400 AMP BUS 225AF! 225AT 125AF! 100AT 208/120V - 3Ø - 4W - 22K AIC 2 225AF! 225AT EMERGENCY LIGHT CONTROL UNIT (ELCU-200) D SCALE: N.T.S. NOTE #4 N 4# 4 & 1# 10G, 2-1/2"C. F N 4# 4 & 1# 10G, 2-1/2"C. E (2)N.O. SWITCH POSITITION SIGNAL 2# 12, 3/4" CONDUIT PHOTOCELL CONTROL! PANEL 30 1 ! SINGLE LINE DIAGRAM NOT TO SCALE ABB-7 SPARE ABB-19 SPARE SPARE SPARE INTERIOR LIGHTING FIELD VERIFY ELEVATOR DISCONNECT LOCATION AND FINAL CONNECTIONS TO CONTROLLER WITH ELEVATOR VENDOR PRIOR TO ROUGH-IN TIMECLOCK CIRCUIT #2 F Fire Alarm Manual Pull Station Circuit Number S1 S2 OVERRIDE! SWITCHES ABB-1 ABB-11 ABB-3 ABB-13 ABB-5 ABB-15 ABB-9 ABB-17 SPARE SPARE SPARE SPARE NOTES: ! ! ! ! 1.! PROVIDE INTERMATIC ELECTRONIC TIME SWITCH ! MODEL #ET70415C FOR LIGHTING CONTROL. ! PROVIDE MOMENTARY CONTACT TOGGLE TYPE ! TIMECLOCK OVERRIDE SWITCHES AS INDICATED ! ON PLANS.! ! ! 2.! OVERRIDE SWITCH COVERPLATES SHALL BE ! ENGRAVED "LIGHTING OVERRIDE". ! ! ! 3.! CONNECT EMERGENCY LIGHTS AND EXIT SIGNS ! TO LINE SIDE OF LIGHTING CONTROLS.! ! ! 4.! COORDINATE WITH OWNER AND PROGRAM ! TIMECLOCK TO OWNER'S SCHEDULE.! ! ! 5.! LIGHTING SHALL FLASH ONCE 5 MINUTES PRIOR ! TO SHUTDOWN BY TIMECLOCK. ! ! ! 6.! ACTIVATION OF LIGHTING OVERRIDE SHALL YIELD ! AN ADDITIONAL 1 HOUR OF LIGHTING.! ! ! 7. OVERRIDE SWITCHES SHALL BE INTERCONNECTED TO TIMECLOCK FOR OVERRIDE OF EACH TIMECLOCK CIRCUIT AS DIRECTED BY MANUFACTURER. Controlling Switch Designation a Lighting Fixture A1 Fixture Type Night Light NL Single Pole Switch Unfused Disconnect Switch 3 Three Way Switch Fused Disconnect Switch Fire Alarm Control Panel Duplex Receptacle - 125V, 2P, 3W Motor Quadraplex Receptacle! - 125V, 2P, 3W Floor Outlet with Devices Indicated AFF MULTIPOLE! CONTACTOR C Emergency Lighting Fixture E 5 Fire Alarm Flashing Light MULTIPOLE! CONTACTOR C NOTE #4 PANEL! 'ELBA' REFER TO SINGLE LINE DIAGRAM NOTE #5 TIMECLOCK CIRCUIT #1 200A! ! 175A E E Fire Alarm Horn F SITE & BUILDING LIGHTING JOCKEY! PUMP FIRE AND JOCKEY PUMP CONTROLLER SHALL BE FURNISHED BY FIRE SUPPRESSION CONTRACTOR Exit Sign ! - Ceiling or Wall Mounted PROVIDE 120 VOLT, 20 AMP CONTROL CIRCUIT, ABC-2 3 FIRE! PUMP PANEL! 'A2A' 15 (2) 125/3! SPACES 3# 3/0 & 1# 3/0G, 2"C. 4# 4 & 1# 10G, 2-1/2"C. GROUND / NEUTRAL BOND 4# 2 & 1# 8G, 1-1/2"C. E 4# 4/0 & 1# 4G, 2-1/2"C. N PANEL! 'ABB' E Incandescent, Fluorescent or High ! Intensity Discharge Lighting Fixture Automatic Detector [ Detector Control Function ]! D - Duct Mounted, Smoke Ionization! F - Thermal, Fixed Temperature! FR - Thermal, Combination Rate of! Rise Plus Fixed Temperature! PE - Smoke PhotoElectric! R - Thermal, Rate of Rise! S - Area Smoke, Ionization! SS - Single Station GFI Duplex Receptacle! - 125V, 2P, 3W Above Finished Floor Communication System Outlet ELCU Emergency Lighting Control Unit + Single Pole, Center Off Momentary Contact Switch Device Mounted Above Counter Top TV Television Outlet SM Manual Motor Switch WP Weatherproof Solid Connection to Equipment GERALD S. BLACKMAN, AIA, PP, NCARB N.J. LIC. No. A1 17113 SERVICE ENTRANCE! EQUIPMENT EXTERIOR WALL N NEW JERSEY Top of Back-Mounted Wall Exit Signs (Not Mounted Above Doors) 6'-0" CITY OF ESTELL MANOR Top of Flush and Surface Mounted Electrical Panelboards and Communication System Cabinets 6'-3" ATLANTIC COUNTY, Normal Neutral (WHITE 18AWG) Emergency Lighting PARTNER: GERALD S. BLACKMAN, AIA, PP, NCARB ASSOCIATE: STEVEN J. BOLOGNO, RA Emergency Power Out (RED 12AWG) UTILITY COMPANY ! 3# 2 & 1# 8G., 2"C Fire Alarm Illuminated Flashing Lights (Lowest of the two Heights) 6'-6" PRINCIPAL: DANIEL A. SHOUSKY AIA, PP, NCARB PRINCIPAL: PAUL A. KISS AIA, PP, NCARB Normal Switched Sense (RED 18AWG) 4-600MCM, 4"C. G Warning and Signaling Fixtures/Signs 6'-8" or 6" Below Finished Ceiling FOUNDER: JOHN J. OLIVIERI (1956-1999) "Switching" Line UTILITY COMPANY TRANSFORMER! 208/120V-3Ø-4W SECONDARY! SERVICE 3# 2 & 1# 8G., 2"C. CONCRETE ENCASED AS REQUIRED BY NEC ARTICLE 695 Pendant Hung Industrial and Strip Lighting Fixtures Center Above! Door or Window! Opening GROUNDING ELECTRODE SYSTEM SHALL! BE PROVIDED IN ACCORDANCE WITH THE! NATIONAL ELECTRIC CODE, ARTICLE 250.50! ! PROVIDE WATER PIPE GROUND CONNECTION! ON STREET SIDE OF WATER METER. 210 E. STREET ROAD TELE # (215)322-7711 SUITE 2D FAX # (215)322-7709 FEASTERVILLE, PA 19053 Normal Neutral 4-600MCM, 4"C. 8'-6" 17 WEST KNIGHT AVENUE, SUITE 200, COLLINGSWOOD, NEW JERSEY 08108 PHONE: (856) 854-0580 FAX: (856) 854-0993 E M METER Battery Lighting Units and Remote Wall Mounted Lighting Heads (Or 1'-0" Below Finised Ceiling) HOLSTEIN WHITE, INC. 125AF! 60AT Normal Lighting ELCU 11 CONSULTING ENGINEERS WEATHERPROOF! LEVEL III SOUND ! ATTENUATED ! ENCLOSURE Wall-Mounted Clocks, Program Bells, Fire Alarm Gongs and Horns 10'-0" ELBA-7 LIGHTING FIXTURE NORMAL LIGHTING CIRCUIT "Sensing" Line 9" Below! Finished Ceiling SINGLE LINE DIAGRAM 125AF! 100AT NEW 3-PHASE AERIAL SERVICE FROM OVERHEAD UTILITY WIRES AT STREET Normal Line EMERGENCY LIGHTING CIRCUIT ESTELL MANOR PARK MANSION VETERANS MUSEUM OUTDOOR NATURAL GAS ! GENERATOR ! 60KW / 75 KVA ! 208/120V-3Ø-4W-60HZ ELECTRICAL STANDARD MOUNTING HEIGHTS INDICATED ON PLANS AS THE FOLLOWING: On/Off Control Device · Relay · Powerpack · Wall Switch ARCHITECTS AND PLANNERS www.olivieriarchitects.com GENERATOR SHALL BE AS MANUFACTURED BY CUMMIS, MTU, CATERPILLER UNLESS OTHERWISE NOTED, ALL DEVICES AND SPACES ARE 3 POLE.! ! UNLESS OTHERWISE NOTED, ALL CONDUCTORS SHALL BE COPPER, TYPE THW, RATED 75ºC.! ! ELECTRICAL CONTRACTOR SHALL CONNECT LOAD TO MAINTAIN BALANCE LOAD IN METER CENTER.! ! PROVIDE (1) NORMALLY OPEN AND (1) NORMALLY CLOSED AUXILARY CONTACT FOR EMERGENCY LOWERING PROVISION. CONTACT SHALL MONITOR DEVICE STATUS (I.E. TRIPPED OR OPEN) AND BE INTERCONNECTED TO THE ELEVATOR CONTROLLER. PROVIDE 2#12 IN 3/4"C. BETWEEN CIRCUIT BREAKER AND ELEVATOR CONTROLLERS, COORDINATE TERMINATION LOCATION IN CONTROLLERS WITH ELEVATOR CONTRACTOR. ! ! INTERCONNECT FIRE PUMP CONTROLLER TO FIRE ALARM SYSTEM TO MONITOR THE FOLLOWING: PUMP RUNNING STATUS, LOSS OF PHASE STATUS, AND PHASE REVERSAL.! ! VERIFY FINAL SIZING OF FIRE AND JOCKEY PUMP PRIOR TO RELEASING GENERATOR TO MANUFACTURE. OSK Design Partners P.A. 1.! ! ! 2.! ! ! 3.! ! ! 4.! ! ! ! ! ! ! ! ! ! 5.! ! ! ! ! 6. THIS PLAN IS NOT VALID UNLESS A RAISED SEAL IS AFFIXED HERETO SINGLE LINE DIAGRAM NOTES GROUNDING ELECTRODE! CONDUCTOR 3 NOT TO SCALE Jeffrey E. Holstein, P.E. License No. NJ GE46443 CONNECTIONS MADE! WITHIN 5' OF POINT OF! ENTRANCE OF PIPE TIMECLOCK ! CONTROL DETAIL Authorization NO; 2GA28143700 GRADE METAL UNDERGROUND! WATER PIPE, (WHERE AVAILABLE) REVISIONS: GROUND! ROD(S) 4 GROUNDING ELECTRODE SYSTEM NOT TO SCALE DATE: 7-1-2014 SCALE: AS NOTED DRAWN BY: JAC CHK'D BY: ISSUED TO ATLANTIC COUNTY FOR REVIEW 1 06-21-2013 DRAWING ISSUE No. DATE JEH PROJECT No. DA09057 E5.0 1.1 0.5 1.1 0.9 1.9 1.9 1.5 0.6 0.6 Description Elevator Pit and Machine Room Cemetary Office 110 Lighting Cemetary Office 110 Receptacles Basement and First Floor Lighting Second Floor and Attic Lighting Spare Spare Spare Space 16.7 60A MCB 22 KAIC Load - KW A B 0.3 0.1 PANEL Cir. No. 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 Total 2.6 2.3 2.4 7.3 Wire Size #12 #12 #12 #12 #12 #12 #12 #12 #12 #12 #12 #12 #12 #12 #12 #12 #12 #12 #12 #12 #12 Description Meeting Room 101 Lighting Meeting Room 101 Lighting Room 102 and 103 Lighting Exterior Porch Lighting Exhibit Area 104 Lighting Meeting Room 105 Lighting Exhibit Area 105 Overhead Lighting Exhibit Area 105 Lighting Room 107, 109, 113, 114, 108, 111 Lighting Exterior Flood Lighting Telecom Equipment Receptacle Basement Receptacles Meeting Room 101 Receptacles Meeting Room 101 Receptacles Rooms 103, 102 Receptacles Meeting Room 105 Receptacles Exhibit Area 104 Receptacles Exhibit Area 106 Receptacles Rooms 107, 109 Receptacles Kitchenette Countertop Receptacle Kitchenette Refridgerator PANEL 13.4 15.6 14.0 43.0 Wire Size #12 #12 #12 #12 #12 #12 #12 Description Hand Dryer Room 113 Hand Dryer Room 114 Kitchenette Microwave UH-1 (Basement 002) UH-1 (Basement 001) CU-5/AHU-5 Basement Water Softener Spare Spare Spare Spare Spare Spare Space Space Space Space Space 5.5 4.8 4.5 14.8 Load Summary by Type Connected Appliance Connected Lighting Connected Motor Connected Heating Connected Air Conditioning Total 1.3 1.3 1.1 225A MCB 22 KAIC Load - KW A B 1.0 1.0 1.8 1.8 A 0.4 Load - KW B 1.3 C 0.4 0.4 0.7 0.7 0.9 1.3 1.2 1.7 0.5 1.1 1.9 2.2 0.4 2.2 0.4 0.9 2.4 2.4 1.1 2.4 1.3 0.7 2.4 2.4 1.3 2.4 0.9 0.4 0.2 6.1 1.0 6.0 43.0 225A MLO 22 KAIC Load - KW A B 1.5 1.5 7.7 9.6 A 0.5 Description C 0.5 1.2 0.5 1.5 1.5 1.5 1.5 1.3 1.3 0.5 4.3 14.8 208/120V - 3Ø - 4W Section 1 of 2 Wire Cir. Size Bkr. Bathroom 113, 114 Receptacles #12 20/1 Elevator Equipment Room 115 Receptacle #12 20/1 Rooms 108, 111 Receptacles #12 20/1 Front Porch Receptacle #12 20/1 Outdoor Receptacles #12 20/1 Meeting Room 105 Receptacles #12 20/1 Spare #12 20/1 AHU-1 #12 20/1 AHU-2 #12 20/1 CU-1 #8 40/2 CU-2 #8 40/2 CU-3 #8 40/2 CU-4 #8 40/2 Spare 20/1 Spare 20/1 Spare 20/1 Spare 20/1 42 POLE C 4.0 KW KW KW KW KW KW 0.5 0.5 Recessed x Surface Double Panel x Ground Bus Insulated Ground Bus 8.0 Load - KW B Cir. No. 2 4 6 8 10 12 14 16 18 Total Options and Accessories - (X) Indicates Selection x Feed Through Lugs Subfeed Main Lugs Split Bus Contactor Controlled Top Bottom KW KW KW KW KW KW Cir. Bkr. 20/1 20/1 20/3 - Description 0.2 1.0 Wire Size #12 #12 #10 - 1.3 42 POLE C Fire Alarm Control Panel Fire Pump Control Panel Well Pump Space Space Space Space Options and Accessories - (X) Indicates Selection Feed Through Lugs Subfeed Main Lugs Split Bus Contactor Controlled Top Bottom KW KW KW KW KW KW 0.5 5.0 Phase (KW) A B C Total Description C 1.3 0.5 Recessed x Surface Double Panel x Ground Bus Insulated Ground Bus 208/120V - 3Ø - 4W Load - KW B 0.5 7.3 Load Summary by Type Connected Appliance Connected Lighting Connected Motor Connected Heating Connected Air Conditioning Total ABB Cir. Bkr. 20/1 20/1 20/1 20/2 20/2 20/2 20/1 20/1 20/1 20/1 20/1 20/1 20/1 A 0.5 1.1 5.8 Phase (KW) A B C Total 0.0 Options and Accessories - (X) Indicates Selection Feed Through Lugs Subfeed Main Lugs Split Bus Contactor Controlled Top Bottom 0.3 Load Summary by Type Connected Appliance Connected Lighting Connected Motor Connected Heating Connected Air Conditioning Total ABB Cir. Bkr. 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 0.0 18 POLE C 0.5 0.8 Phase (KW) A B C Total 0.0 KW KW KW KW KW KW 20/1 20/1 20/1 20/1 Battery Charger Block Heater Remote Annunicator Panel Space Space Space Space Space Space Space Space Space Space Space Space Space Space Space Space Space Space Recessed x Surface x Double Panel x Ground Bus Insulated Ground Bus 208/120V - 3Ø - 4W Section 2 of 2 Wire Cir. Size Bkr. #12 20/1 #12 20/1 #12 20/1 0.5 Options and Accessories - (X) Indicates Selection x Feed Through Lugs Subfeed Main Lugs Split Bus Contactor Controlled Top Bottom Cir. No. 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 Total Recessed x Surface x Double Panel x Ground Bus Insulated Ground Bus Cir. No. 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 Total Determine and pay any and all charges required by Power Company. Have electrical service available when required by construction schedule.! ! Verify locations of existing underground services in the area of construction. Verify existing locations of underground electrical services, natural gas piping, water services and sanitary piping which may affect work.! ! Lay out all work from approved building and property lines and benchmarks. Verify and be responsible for the correctness of all measurements in connection with work. Any change made in major overall dimensions as shown which affect the physical size, shape, or location of any part of the Work, whether due to field check or changes due to the use of equipment of a manufacturer other than that used as the basis of design shall not cause any interference with other work.! ! Electrical equipment shall not interfere in any way with other material or equipment and shall provide adequate working space; see Requirements for Electrical Installations, Article 110 and other related articles of the National Electrical Code.! ! Provide materials, equipment, supplies and labor necessary as required to adequately support, brace and strengthen all equipment and materials furnished as part of this work.! ! Locations are subject to changes that may be necessary to avoid obstacles in building construction. Verify all dimensions and conditions at site. Check layout for sizes and clearances, and provide so that the apparatus and material may be installed and operated satisfactorily in space provided. Install equipment and raceways to preserve headroom and to keep openings and passageways clear.! ! Protect all conduit, fittings, panelboards, switchgear, transformers and other equipment before and during installation and keep clean.! ! Identify each panelboard, transformer, and other electrical equipment as to nature, service and purpose, by means of permanently attached, approved size, laminated phenolic nameplates.! ! Fully coordinate installation, wiring and connection of service and distribution systems with the owner and Atlantic City Electric.! ! Coordinate with Power Company; inform them of the proposed work; obtain their approval before beginning work; comply with their requirements for details of installation and materials used.! ! Where sleeves containing a single conduit penetrate FIRE RATED walls, floors, partitions or slabs, fill and seal conduit to the sleeve with a 1-part intumescent caulk/putty sealant creating a fire stop equal to or exceeding fire rating of construction material being penetrated. Fire sealant shall prevent spread of flame, smoke, air and water through the sleeve and shall pass 3 hour test per ASTM E814 and UL 1479. Fire sealant shall be installed in accordance with manufacturer's written instructions. Where sleeves containing multiple conduits or multiple cables penetrate FIRE RATED walls, floors, partitions, or slabs, fill and seal spaces between the conduits or cables and the sleeve with 2-part intumescent foam sealant creating a fire stop equal to or exceeding fire rating of construction material being penetrated. Fire sealant shall prevent spread of flame, smoke, air and water through the sleeve and shall pass 3 hour test per ASTMA E814 and UL 1479. Fire sealant shall be installed in accordance with manufacturer's written instructions. Where sleeves penetrate exterior walls, fill and seal ends around conduits and/or cables with duct sealant compound equal to Solorite KN--1146, or Link Seal. Install seals in accordance with the manufacturer's recommendations to provide air tightness above ground and hydrostatic sealing below grade. Caulking or other type mastic is not acceptable. Where wiring devices are placed in fire rated construction, fire rating of installed assembly shall meet or exceed the rating of the construction.! ! Telephone, data, CCTV, and security cabling shall be by owner's communications and security contractors. Obtain a copy of owners low voltage plans and provide box, conduit, and pull strings to facilitate installation of low voltage devices by others.! ! Provide for each voice and data outlet a 4x4 outlet box with pullstring to accessible ceiling space. In non-fishable construction, provide 3/4” conduit with pullstring between outlet box and accessible ceiling space.! ! Provide for each CCTV location a 4x4 outlet box with pullstring to accessible ceiling space. In non-fishable construction, provide 3/4” conduit with pullstring between outlet box and accessible ceiling space. Provide weatherproof gasketed cover plates for outdoor locations.! ! 120 Volt Switches shall be quiet toggle type with totally enclosed case, rated 20 ampere, specification grade, color as selected by Architect.! ! Dimmable switches shall be 120 volt switches rated for load controlled (i.e. incandescent, magnetic or electronic low voltage, fan speed, or fluorescent). Switch shall be dimmable thru the entire range from 0 to 100%, with preset control and seperate on-off switch. Switches shall be as manufactured by Lutron, Levition, or Pass & Seymour. Care shall be taken when derating switches for installation in multi-gang switch boxes. Install switches with highest loads on outside of boxes to minimize the quantity of cooling fins (sides) removed. Contractor shall be responsible to ensure quantity of sides removed does not derate switch below required capacity. Multiple switch boxes shall be provided as required to maintain ratings of switches. All switches shall be installed in accordance with manufacturers instructions.! ! Standard duplex receptacles shall be polarized, duplex, parallel blade, U-grounding slot, specification grade, rated 20 amperes, 125 volts, style and color as selected by Architect.! ! GFI receptacles shall be 125V, 20 amp rated, as manufactured by Leviton or equal, style and color as selected by Architect. Trip threshold and time shall be as required for the application in accordance with the NEC.! ! Plates for Flush Devices shall be stype and color as selected by Architect.! ! Contactors shall be permanent magnetic latched, electrically operated, mechanically-held type with number of poles and current rating as shown. Operating coils shall be 120 volts as required. Contactors shall be housed in NEMA Type 1 enclosures with knockouts and provisions for padlocking or incorporated in branch circuit or distribution panelboards as indicated. Provide hand-off-automatic switch in cover to facilitate safe maintenance. Contactors shall be UL listed for switching 208 volt ballast inductive loads. Install, completely wire and connect all systems in accordance with details on Drawings and manufacturer's instructions.! ! Furnish and install all lighting fixtures specified on these plans, or by other consultants. Provide all interior and exterior lighting fixtures complete with sockets, reflectors, diffusers, shades, holders, lamps, ballasts, protective devices and all other required appurtenances. Prior to ordering lighting fixtures, verify exact type of ceiling to be used for each space. Coordinate with Division 15 to avoid conflicts between lighting fixtures and Mechanical and Plumbing piping, ductwork, supports, fittings and equipment. Furnish to other trades, plaster frames, trim rings, etc., where required.! ! Motor and circuit disconnect means shall be a horsepower rated safety switch or a circuit breaker, each sized for the applied load and system voltage having an interrupting capacity not less than maximum available short-circuit current of circuit on which applied. Disconnects shall be sized in accordance with NEC and NEMA requirements. Safety switches shall be cartridge fuse type or unfused, as required. Manual toggle type motor switches with overload protection may be used as motor disconnects for fractional horsepower motors provided they meet NEC requirements including padlock provision. Safety switches shall be quick-make, quick-break and NEMA Heavy Duty, Type HD. Disconnect enclosures: NEMA 1, NEMA 3R, NEMA 4 to suit application.! ! Provide new Addressable Fire Alarm system as manufactured by Edwards. The system shall include, but not limited to: control panel, dialer, alarm initiating and indicating peripheral devices, conduit, wire and accessories required to furnish a complete operational system. The equipment and installation shall comply with the current provision of the National Fire Protection Association Standards, 70, 72, and all local codes. All equipment shall be UL listed. Flashing lights shall be ADA approved, candela as required by location. Contractor shall use equipment manufacturer or manufacturers representative for all system testing and programming.! ! FIRE ALARM SUBMITTAL REQUIREMENTS: In addition, the contractor shall prepare a Fire Alarm system submittal to fulfill the requirements of the local Fire Marshall. Submit (3) sets of Signed and Sealed plans prepared by a professional engineer or certified Fire Protection Engineer for Fire Marshall review. The submittal shall include the following: Scaled plans indicating Fire Alarm work, Project Name and Address, Square footage, Fire Alarm symbols list, Device matrix showing description and quantity of devices, Equipment Cut sheets, Wiring information including size, type, and all point to point wire runs, Fire Alarm Riser diagram including initiating and annunciating devices, Battery calculations and proposed battery capacity, and voltage drop calculations.! ! Provide PVC conduit buried 30 inches minimum below finished grade, or as otherwise indicated, for services and feeders.! ! Provide underground ducts in a straight line. Pockets where water can accumulate in conduits will not be permitted.! ! All underground conduits shall be watertight. Dope threads of steel conduit before joining. PVC conduits shall be chemically bonded around entire circumference of the conduit at each joint. Provide minimum length of 6 feet of rigid steel conduit when entering or running under manholes, transformer pads, at building walls or foundations and on both sides of roads. Conduits under roads shall be rigid steel.! ! Contractor shall include in his bid Unit Prices for each of the following:! A. Each type of receptacle, including coverplate connected to area circuit. ! B. Voice outlet box with conduit and pullstring.! C. Each type of switch, including coverplate connected to area circuit.! D. 20/1 Homerun to Local Branch Circuit Panel.! ! Circuit breakers used as elevator disconnects shall be listed, and shall capable of locking the breaker in the open position. The locking provision shall remain in place with or without the lock installed. Portable means for adding a lock shall not be permitted.! ! Electrical contractor shall ensure all electrical plans are furnished to the Elevator Contractor for inclusion with submission to Elevator Inspector for review.! ! Electrical contractor shall work closely with Elevator contractor to ensure work in areas under Elevator Inspector juristiction are approved prior to installation. Make modifications as required to meet the requirements of the Elevator Inspector.! ! Floor Outlets shall be provided as follows: Type A: Provide Legrand Evolution series 6AT with quadraplex receptacle. Data and AV outlets shall be provided by Owners Low voltage contractor.2! NEW JERSEY 35.! ! ! 36.! ! ! 37.! ! ! ! ! 38.! ! ! 39.! ! ! 40.! ! ! ! 41.! ! 42.! ! ! 43.! ! 44.! ! ! 45.! ! ! ! ! ! ! ! ! ! ! ! ! 46.! ! ! 47.! ! ! 48.! ! ! 49.! ! ! 50.! ! ! ! ! ! ! ! 50.! ! ! 51.! ! ! 52.! ! 53.! ! ! ! ! ! 54.! ! ! ! ! ! 55.! ! ! ! ! ! ! 56.! ! ! ! ! ! 57.! ! ! ! ! ! ! 58.! ! 59.! ! 60.! ! ! ! 61.! ! ! ! ! ! 62.! ! ! 63.! ! ! 64.! ! ! 65. CITY OF ESTELL MANOR 0.9 Contractor shall provide all labor, materials, tools, apparatus and equipment required to complete his work in accordance with the contract documents, codes, laws and ordinances, and accepted trade procedures.! ! The contractor by his acceptance of the contract guarantees that all work installed shall be free from all defects in workmanship and materials and that all apparatus furnished by him shall develop the capacities and characteristics specified. He further guarantees that if, during a period of one (1) year from the date of the certificate of completion and acceptance of the work, any such defects in workmanship, material or performance appear, such defects shall be remedied by him without cost to the owner. If the contractor fails to remedy the defects as outlined within a reasonable length of time, to be specified in a notice from the owner's authorized representative to the contractor, the owner will have such work done, and he will charge the cost to the contractor.! ! The contractor shall visit the site before he submits his proposal. He shall examine all existing conditions which affect the work. The submission of the proposal shall be considered evidence that this requirement has been fulfilled. No extra payment will be allowed for additional work made necessary by the failure to visit the site.! ! Electrical equipment shall be installed in a neat and workmanlike manner in accordance with latest and best practices of the trade. Only mechanics skilled in this type of Work shall be employed and utilized by Contractor for this Division in the execution of this Work.! ! The contract drawings are diagrammatic and indicate the general arrangement of all systems and work included in the contract. The contract drawings are not to be scaled. The architectural contract drawings and details together with the other contract documents shall be examined for all dimensional information.! ! The contractor shall, without additional costs to the owner, make reasonable modifications in the layout of his work in order to prevent conflicts with the work of other trades or for the proper execution of his work.! ! The contractor shall provide and maintain in good order a complete set of blueline prints of the contract drawings. As the work progresses, the actual location of all work shall be clearly recorded, including all changes to the contract and equipment size and type. These prints shall be available at the site for inspection at all times. At the conclusion of the work, the contractor shall, at his own expense, obtain a set of reproducibles of the original contract drawings, and utilizing the symbols on the contract drawings, shall incorporate all "as built" data in a clearly legible and reproducible manner. All schedules shall be corrected to indicate "as built" conditions. All revisions shall be incorporated on these reproducibles including all sketches and written directives. All concealed equipment, mainfeeders, pull and junction boxes, etc. shall be dimensionally located from the building structure. As a condition for acceptance of the work, the "as built" reproducibles and one (1) set of prints shall be signed, dated and delivered to the engineer.! ! The contractor shall supply all labor required to perform all work which may be claimed by trade organizations within his jurisdiction. All work shall be performed without any additional cost to the owner irregardless of which section of the contract documents the work is described. The contractor shall be responsible to verify with all local organizations the extent of any collective bargaining agreements and/or any jurisdictional decisions rendered regarding disputes between the respective trades, and provide and install his work in accordance with the accepted trade practice in the area.! ! The entire installation shall conform with all pertinent codes and regulations of the local, municipal, county, state, and federal authorities, The National Board of Fire Underwriters, the codes of the International Codes Council, the codes of the National Fire Protective Association, the New Jersey Uniform Construction Codes, and all other regulatory bodies having jurisdiction. All materials and equipment shall bear the stamps or seals of the NFPA, ASME, NEMA, IEEE, UL and other recognized industry regulatory groups.! ! The contractor shall give all necessary notices, obtain all permits, pay all governmental taxes, fees and other costs in connection with his work. He shall file all necessary plans, and prepare all other documents including additional detailed plans that are required for compliance with all applicable laws, ordinances, rules and regulations.! ! Before starting any work under this Contract, file for inspection with the Middle Department Inspection Agency or other certified Agency. Upon completion of the work, furnish Electrical Certificates from said Agency for all Electrical equipment and systems installed or furnished and installed as part of the work.! ! The contractor shall at all times keep the premises free from the accumulation of waste materials or rubbish caused by his employees or work. At the completion of the work, he shall remove all superfluous materials, equipment and debris resulting from the work.! ! All feeder wiring shall be soft drawn copper of 98% conductivity, installed in code conforming metallic raceways or cable assemblies. All wiring shall be copper, thermoplastic covered insulated Type 75° C. THW or 90° C. Type THHN, 600 volt rating. Wire No. 8 AWG and smaller shall be solid. Wire larger than No. 8 shall be stranded.! ! All wiring shall be insulated copper conductors installed in code conforming raceways or cable assemblies.! ! All wiring shall be run concealed wherever possible. All exposed conduit shall be EMT or rigid steel as required. Flexible conduit shall be smooth liquidtight with appropriate fittings. Conduit drops from above ceiling shall be structurally secured and supported. Cable assemblies used for branch circuits shall not be run exposed. Cable assemblies shall be permitted exposed for final connections to Mechanical and Plumbing equipemnt and shall be limited to 6 feet total length, routing shall not interfere with equipment workspace.! ! Where conductors connect directly to equipment, the insulation temperature rating of the conductor shall meet or exceed the equipment temperature rating.! ! Where dimmers are provided, install a separate neutral conductor for each branch circuit.! ! Color code conductors to designate neutral conductor and phases.! ! Exercise great care in maintaining a uniform and consistent arrangement of phase conductors on all systems. Throughout the entire wiring systems, each phase conductor must always be in the same physical position with respect to the other phase wires at equipment terminals.! ! Grounding shall comply with Article 250 of NEC and to approval of local Underwriters inspection authorities.! ! Panelboards shall be dead front type with plated aluminum bus, bolt-on breakers, fully rated neutral bus and grounding bus block. Cabinet shall be code gauge galvanized steel, NEMA 1, minimum 20” wide, 5-3/4”deep. Cover shall have door and trim and adjustable clamps, gray baked finish, and tumbler type key lock. Directories shall be typed. “Spaces” shall be fully bussed and drilled, ready for breaker installation.! ! Circuit Breakers shall be molded case, bolted, thermal magnetic trip in each pole, enclosure-compensated to carry full rated load at 40°C., trip-free handles shall clearly indicate trip, on and off condition, quick-make and quick-break action. Lugs approved for copper and aluminum conductors and compression type. Ground Fault type breakers shall be provided with thermal and magnetic protection, UL Class A, 5 milliampere ground fault sensitivity, where required. Circuit breakers used as switches in 120 and 277 volt circuits feeding incandescent, fluorescent, and/or HID fixtures shall be approved for such use and marked "SWD", per NEC. Circuit breakers serving Heating and Air Conditioning equipment shall be HACR rated.! ! Provide all labor, materials and equipment required to provide electric power to meet the requirements for heating, ventilating, air-conditioning and plumbing systems. Fully coordinate installation of electrical wiring and equipment with installation of electrically operated mechanical equipment provided by the Mechanical and Plumbing Contractors. Install disconnect switches, motor starters, and control transformers furnished by Mechanical and Plumbing Contractors. Provide final equipment electrical terminations. All internal equipment wiring shall be by manufacturer.! ! Test equipment, including panelboards and all other equipment and wiring for unintended grounds, short circuits, open circuits, continuity, current leakage, and that equipment will operate as specified. Test feeders for insulation resistance; for load balance of the final installation, and for overall operation of systems. Furnish labor and material required for making such tests and make corrections necessary to balance the load and to obtain proper operation.! ! Where existing facilities are being altered, disconnect and remove or relocate all existing electrical work that interferes with or is necessary because of new construction as specified, shown or required.! ! Perform alterations and additions to present electrical systems with a minimum interruption in the operation of these systems. Obtain written clearance from Owner for such interruptions and schedule same at whatever time specified in writing by Owner.! ! Circuit breakers made spare due to demolition shall be set in off position and labeled 'SPARE'.! ! Where specified or required, extend existing systems or tie into same to provide a complete coordinated electrical system to satisfaction of Owner and Architect.! ! Perform all work necessary to permit operation of all existing systems during the construction period. Provide and maintain applicable approved temporary wiring to meet this requirement.! ! Demolish and remove existing electrical equipment, feeders and conduit no longer required by new construction.! ! Perform alteration of utilities and services in accordance with the rules, regulations and requirements of the involved utility companies and regulatory agencies having jurisdiction.! ! Arrange and pay for the relocation, disconnection or removal of existing utilities and services where shown and where such utilities or services interfere with new construction, whether shown or not. Provide all excavation, backfilling and paving, manholes, and cables required by such work.! ! Fully coordinate installation, wiring and connection of service and distribution systems with the owner, Atlantic City Electric and all contractors.! ! Coordinate with Power Company; inform them of the proposed work; obtain their approval before beginning work; comply with their requirements for details of installation and materials used. ATLANTIC COUNTY, 1.1 0.2 1.! ! ! 2.! ! ! ! ! ! ! 3.! ! ! ! 4.! ! ! 5.! ! ! ! 6.! ! ! 7.! ! ! ! ! ! ! ! ! 8.! ! ! ! ! ! 9.! ! ! ! ! 10.! ! ! ! 11.! ! ! ! 12.! ! ! 13.! ! ! ! 14.! ! 15.! ! ! ! ! 16.! ! ! 17.! ! 18.! ! 19.! ! ! ! 20.! ! 21.! ! ! ! ! 22.! ! ! ! ! ! ! 23.! ! ! ! ! ! 24.! ! ! ! ! 25.! ! ! 26.! ! ! 27.! ! 28.! ! ! 29.! ! ! 30.! ! 31.! ! ! 32.! ! ! ! 33.! ! ! 34. PARTNER: GERALD S. BLACKMAN, AIA, PP, NCARB ASSOCIATE: STEVEN J. BOLOGNO, RA 0.7 6.1 ELECTRICAL SPECIFICATIONS Cir. No. 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 Total PRINCIPAL: DANIEL A. SHOUSKY AIA, PP, NCARB PRINCIPAL: PAUL A. KISS AIA, PP, NCARB 1.1 1.1 Cir. Bkr. FOUNDER: JOHN J. OLIVIERI (1956-1999) Wire Size #12 #12 #12 #12 #12 Total Cir. No. 43 45 47 49 51 53 55 57 59 61 63 65 67 69 71 73 75 77 79 81 83 Total 0.4 5.8 Wire Size Space Space Space Space Space Space Space Space Space Space Space Space Space Space Space Space Space Space Spare Spare Spare 0.4 Load Summary by Type Connected Appliance Connected Lighting Connected Motor Connected Heating Connected Air Conditioning Total ELBA Cir. Bkr. 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 C GERALD S. BLACKMAN, AIA, PP, NCARB N.J. LIC. No. A1 17113 CONSULTING ENGINEERS Cir. No. 1 3 5 7 9 11 13 15 17 A Description 210 E. STREET ROAD TELE # (215)322-7711 SUITE 2D FAX # (215)322-7709 FEASTERVILLE, PA 19053 PANEL 4.8 5.8 6.1 16.7 C 208/120V - 3Ø - 4W Load - KW B 0.2 4.8 Phase (KW) A B C Total 42 POLE ESTELL MANOR PARK MANSION VETERANS MUSEUM Offices 201, 204 Lighting Rooms 200, 202 Lighting Room 203, 209, and 205 Lighting Rooms 206, 207, 208 Lighting Attic Lighting Office 201 Receptacles Office 204 Receptacles Rooms 200, 202 Receptacles Office 203 Receptacles Toilet Room 209 Receptacle Office 205 Receptacles Workroom 206 Receptacles Rooms 207, 208 Receptacles Attic 305-309 Receptacles Attic 300, 302, 303, 304 Receptacles AHU-3 AHU-4 Hand Dryer Room 209 Flood Lighting Second Floor Attic 301 Receptacles Spare 125A MLO 22 KAIC Load - KW A B 0.3 0.1 ARCHITECTS AND PLANNERS www.olivieriarchitects.com Description 17 WEST KNIGHT AVENUE, SUITE 200, COLLINGSWOOD, NEW JERSEY 08108 PHONE: (856) 854-0580 FAX: (856) 854-0993 Wire Size #12 #12 #12 #12 #12 #12 #12 #12 #12 #12 #12 #12 #12 #12 #12 #12 #12 #12 #12 #12 HOLSTEIN WHITE, INC. A2A Cir. Bkr. 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 OSK Design Partners P.A. Cir. No. 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 Total THIS PLAN IS NOT VALID UNLESS A RAISED SEAL IS AFFIXED HERETO PANEL Jeffrey E. Holstein, P.E. License No. NJ GE46443 Authorization NO; 2GA28143700 REVISIONS: DATE: 7-1-2014 SCALE: AS NOTED DRAWN BY: JAC CHK'D BY: ISSUED TO ATLANTIC COUNTY FOR REVIEW 1 06-21-2013 DRAWING ISSUE No. DATE JEH PROJECT No. DA09057 E5.1 e w Je r s e y S t a t e H i 18 18 18 10-WAY DISTRIBUTION BOX TREE TO BE REMOVED (typ.) 18 IUS ' RAD (typ.) 18 150 17 g h w a y 17 17 17 17 17 17 DS AN TL WE FER F BU FRONT TOP SIDE , NCARB 0' 15 # 5 0 5"