Voltage Drop Tables The National Electrical Code limits voltage drop to a maximum of 5% of nominal. Circuit runs must be of sufficient capacity to TABLE A - IMPORTANT ELECTRICAL INSTALLATION INFORMATION 12 VOLT SYSTEM TOTAL WATTS ON WIRE RUN #12 6 378 8 283 7 WIRE GUARD 94 450 716 1138 8 70 570 450 409 338 300 180 108 24 6 189 113 21 1518 818 212 119 20 955 257 133 18 600 283 162 16 #6 360 178 14 #8 515 226 12 #10 MAX. LENGTH OF WIRE RUN (FEET) 324 10 6 VOLT SYSTEM TOTAL WATTS ON WIRE RUN 286 171 89 273 141 225 1301 #12 7 910 10 650 14 715 477 455 434 357 112 179 284 162 84 134 75 119 71 43 24 178 102 45 27 227 112 47 28 325 143 53 30 24 379 204 64 33 21 238 70 40 20 150 90 44 18 #6 129 56 16 #8 MAX. LENGTH OF WIRE RUN (FEET) 81 12 538 WIRE GUARD #10 114 68 38 108 60 95 25 86 136 216 344 25 21 34 54 86 30 75 120 190 303 30 19 30 48 76 40 53 85 135 214 40 13 21 33 53 35 65 48 103 44 50 70 43 75 31 16 10 250 36 19 10 225 43 23 12 200 54 27 14 175 72 34 17 150 108 45 21 125 112 68 28 100 164 27 16 9 25 14 22 260 35 178 15 48 172 11 50 115 100 57 150 69 49 175 42 200 40 225 36 250 12 6 4 2 14 8 4 2 17 9 5 2 21 11 5 3 29 14 7 3 43 18 8 4 44 27 11 5 63 28 17 7 125 39 17 11 75 86 25 10 6 3 10 5 9 Values not shown in Table A may be calculated using the following formulas: I. Maximum Length (Feet) = Table B Constant Value Maximum Load (Watts) Example: Find the maximum circuit length for #8 wire on a 24 volt system with an 80 watt load. Maximum Length (Feet) = 21613 ÷ 80 = 270 feet. Table B Constant Value Maximum Length (Feet) Example: Find the maximum circuit load for 540 feet of #12 wire on a 32 volt system. Maximum Load (watts) = 15197 ÷ 540 = 28 watts. II. maximum Load (Watts) = SYSTEM TABLE B – CONSTANT VALUES PER VOLTAGE SYSTEM WIRE SIZE (MAXIMUM VOLTAGE DROP 5%) 6 VOLT WIRE SIZE CONSTANT #12 534 #10 849 12 VOLT #8 350 #6 2148 #12 2137 #10 3397 32 VOLT SYSTEM WIRE SIZE CONSTANT #12 15197 #10 24157 #8 38423 #8 5403 24 VOLT #6 8590 #4 13660 #12 8548 #10 13588 48 VOLT #6 #4 61090 97140 #12 34193 #10 54353 #8 21613 #6 34363 #4 54641 110 VOLT #8 #6 #4 #12 #10 #8 #6 #4 #2 86452 137454 218565 179575 285450 454025 721875 1147850 1824900 Uniform Loads The maximum circuit length data in Table A (and derived from Table B) assumes that 100% of the load is concentrated at the end of the run. If equally sized loads can be equally spaced along the run, maximum circuit length can be increased by the multipliers shown in Table C. TABLE C - MULTIPLIERS FOR EQUALLY SIZED, EQUALLY SPACED LOADS (MAXIMUM VOLTAGE DROP 5%) NUMBER OF FIXTURES MULTIPLY DISTANCE BY 2 2 1.333 3 3 1.500 4 4 1.600 5 5 1.670 6 6 1.714 7 7 1.750 8 8 1.777 9 9 1.800 10 10 1.818 N N 2n /(n +1) Information republished is for reference only. Local codes and the local authority having jurisdiction are the most reliable sources to ensure code compliance. Dual-Lite • www.dual-lite.com A Hubbell Lighting, Inc. brand with representatives’ offices in principal cities throughout North America. Copyright © bject to change without notice. • Printed in U.S.A. 0600686 Rev C 1/16