EPIGAP Optronic GmbH Data Sheet IR photodiode EOPD-1300-5-0.3

advertisement
EPIGAP Optronic GmbH
Koepenicker Str. 325b
D-12555 Berlin
Fon: +49 (0)30 657637 60
Fax: +49 (0)30 657637 70
sales@epigap-optronic.de
Data Sheet
IR photodiode
Radiation
Infrared
page 1 of 2
Rev. 02, 2014
EOPD-1300-5-0.3
Type
Planar
Technology
InGaAs/InP
Case
5 mm plastic
Description:
InGaAs-Photodiode mounted in standard 5 mm
package without standoff . High spectral
sensitivity in the infrared range (NIR, SWIR).
Application:
Optical communications,
safety equipment, light barriers
Maximum Ratings
Tamb= 25°C, unless otherwise specified
Parameter
Active area, diameter
Temperature coefficient of photocurrent
Operating temperature range
Storage temperature range
Optical and Electrical Characteristics
Tamb= 25°C, unless otherwise specified
Parameter
1)
Breakdown voltage
Dark current
Peak sensitivity wavelength
Responsivity at 1300 nm
Sensitivity range at 10%
Spectral bandwidth at 50%
Shunt resistance
Noise equivalent power
Specific detectivity
Junction capacitance
Photocurrent at = 1300 nm 1)
1)
Symbol
Value
300
7.4
-40 to +85
-40 to +100
AØ
TC(IPh)
Tamb
Tstg
Test conditions
IR=10 µA
VR=5 V
VR=0 V
VR=0 V
VR=0 V
VR=0 V
VR=10 mV
Symbol
VR
ID
λp
Sλ
λmin, λmax
āˆ†λ0.5
RSH
λ = 1300 nm
λ = 1300 nm
VR=0 V
VR=0 V
Ee=1 mW/cm²
NEP
D
CJ
4x10-15
4.5x1012
11
Iph
0.95
Min
Unit
μm
%/K
°C
°C
Typ
Max
15
1600
0.9
40
5
800
3
1750
680
5
Unit
V
pA
nm
A/W
nm
nm
Gā„¦
W/ Hz
cm āˆ™ Hz āˆ™ W
pF
µA
for information only
We reserve the right to make changes to improve technical design and may do so without further notice. Parameters can vary in different applications. All
operating parameters must be validated for each customer application by the customer.
EPIGAP Optronic GmbH
Koepenicker Str. 325b
D-12555 Berlin
Fon: +49 (0)30 657637 60
Fax: +49 (0)30 657637 70
sales@epigap-optronic.de
Data Sheet
IR photodiode
EOPD-1300-5-0.3
page 2 of 2
Rev. 02, 2014
We reserve the right to make changes to improve technical design and may do so without further notice. Parameters can vary in different applications. All
operating parameters must be validated for each customer application by the customer.