Lighting

advertisement
Harsh & hazardous
Lighting Products
overview
Complete Lighting Line
Aluminum/Non-Metallic
Hostile & Hazardous Location

Fluorescent – Linear and Compact

HID (HPS & Metal Halide)

Induction – Great for cold climates

Battery Fluorescent (Emergency)

Incandescent

Xenon (Signals)

LED
Industrial General Purpose
or C1D2 - C2D1
C1D1 Explosion-Proof
Lighting
Lighting
LAL Series
CL l Div. 2,
Groups A, B,C,D
CL l Zone 2,
Groups llC, llB, llA
CL ll, Div. 1 & 2,
Groups E,F,G
AEx nAll, Ex All
Wet Locations
NEMA 4X, IP66
ABS Pending
IECEx
Zone 2 and Zone 21 areas
Ex nA IIC T6 to T3, Gc
Ex tb IIC T95°C Db
Tamb -50°C≤Tz≤+65°C, IP66
IECEx Certificate
QPS 15.0010
ATEX Certificate
CML 15ATEX4081X (nA)
CML 15ATEX3082X (tb)
Lighting
Side-by-Side
Killark LAL
Pauluhn DLL
Rig-A-Lite MHL
IP66
IP66
IP66
IP66
IP66
Class 1 Div 2 Groups
A,B,C,D
A,B,C,D
A,B,C,D
A,B,C,D
A,B,C,D
Class 2 Div 1 Groups
E,F,G
F,G
F,G
Not Listed
E,F,G
~16000
7,100
7,654
4380 @ 6500 K
7,000
On Chassis
Separate box
Only Mentioned
-
On Chassis
N/A
50 feet
-
-
N/A
-20°C to 50°C
-20°C to 50°C
-
-
-20°C to 65°C
up to 149
130
up to 102
IP Rating
Lumens
Emergency
Max Distance from
fixture
Emergency
operating
temperatures
Lumens per watt
Rated Life
60,000
Warranty
5 years
Crouse Hinds LL48 Dialight SafeSite
106
Temp code 40°C
T6
T6
T4A
T5
T5
Temp code 55°C
T5
T5
T4A
T4A
-
Temp code 65°C
T5
T5
T4A
Not Listed
-
2 foot weight
~19
12.5
10
-
-
4 foot weight
~28
22.5
18
-
-
Lighting
LED vs Fluorescent
Much Higher L/W = Lower Energy Costs
Lighting
LZ2NL – LZ2SL Linear LED
• 2’ and 4’ models - 18W to 120W
• 2500 - 16000 Lumens
• 130 to 150 Lumens per Watt
• Ambient Sustainability -40°C to 55°C
• LED Array Life up to 212,000 Maintenance Free
Hours
• Crisp White 5000 Kelvin Light (Noon Sunlight)
• Thermal Shock and Impact Resistant Polycarbonate
Lens
Lighting
HLLX Series Lighting
• Class I Division I
• Wet Location Listed
• NEMA 3, 4X, 7(C,D), 9(E,F,G)
• Suitable for Wet Locations
• Suitable for Paint Spray Booths
• Factory Sealed
Lighting
Lighting
MBL SERIES
Wattage Range 14 – 50W
New Flat Lens Optics (to 25W)
Flat: Polycarbonate or Glass
Lighting
MBL Series Flat Lens LED
Very Compact Size – Ideal for:
> Tunnels – low ceiling or narrow passage
> Walkway lighting from handrails
> Variety of aiming possibilities
Patent Pending
Lighting
MBL2530 Flat Lens LED
•
•
•
•
•
•
•
Flat Lens 14 - 25W
Class I Div. 2; Class II Div 1; N4X
Pendant, Ceiling, Wall, Stanchion
Ceiling Mount Can be “Side mounted” for minimum Depth
--- Good for very low ceilings or narrow corridors/tunnels
--- Only 7-3/8” deep w/ ceiling mount
Options:
• “Wallwash” Glare Guard (similar to a mini Wallpack)
• Wire Guard
Shown with
“Pathway” reflector on
Ceiling Mount To Wall
Lighting
VM1L Series
• Wattage Range: 40W, 45W, 50W
• Maintains all CertiLite®V Features including
• 8 Mounts: Pendant, Ceiling, Wall, Cone Top
25° Stanchion, 90° Stanchion (Straight)
EZ Adapter, Tank Adapter
• Multiple Optics and Reflectors
• “Earthquake Tab” for Optional Safety Cable
• Factory mounted photocell Option
• Backward compatibility with CertiLite® VM mounts as
old as 40+ years – Users can “GREEN” UP to the Latest
Technology for Hostile or Hazardous Environments
Lighting
Key Exclusive Feature
Swing Barrel-Nut
•
•
•
•
•
•
Stainless Steel Connection
Take the “Load Off” for the installer
Just hang and tighten
Ordinary screwdriver
Saves Time and Labor
Backward Compatibility With Old VM
Lighting
VM1L Series
• 8 Mounts: Pendant, Ceiling, Wall, Cone Top
25° Stanchion, 90° Stanchion (Straight)
EZ Adapter, Tank Adapter
• Ceiling mount available in 4 or 5 Hub models
• 5-hub often utilized for tunnels as temporary lighting
• Center Hub Hangs, Side Hubs Feed
• Sizes: ¾”, 1”, M20
Lighting
Tank Adapters
Allows Killark Fixtures to be mounted directly to
competitions splice boxes.
• Especially helpful for
ceiling or wall mounts where
there is incoming and
outgoing conduit
• Upgrade from Mercury
etc. to GREEN Technology
Other Adapters Available
• Crouse® Deep – 70’s Wall
• Appleton® MercMaster ®II
• Appleton®MercMaster ® III
• Hazlux®3
• Holophane® Ceiling
• Petrolux®2
• GE®
Lighting
VM1L Series
• Multiple Optics include
• Globes, with or without Dome or Angle Reflectors
• All-Glass Type V (minimizes Hot Spots)
• Spin-Top Refractors Type V in 8” and 12”
• Guards for all of the above
Type V Refractor
Even Pattern
Focused Out &
Downwards
Lighting
VM1L Series
Accessories – Options
• Fuses, Terminal Blocks, Assembly of Mount & Optic
• Reflectors, Exit Sign
Lighting
VM4L
IECEx
Ex nA IIC T4, Gc
Ex tb IIIC T83°C Db
Tamb -40°C≤Ta≤+65°C, IP66
QPS 15.00006
Lighting
2011 Heat Sinks
K
C
A
Late 2012 – 2013 Heat Sinks
K
?
C
A
Lighting
Concave
Bulb
> Two Constructions: Concave and Bulb; Same Wattage = same $
> Pricing moves based on L/W Performance, not wattage
> C has less GLARE, but less Lumens; B has more Lumens, but more Glare
Lighting
Many choices:
• Concave or Bulb LED Array
• Mounts
• Optics
Flat Lens will be an option for
VM4LC “Concave” Models
Lighting
EML Series
• 40W – 50W LED Explosion-proof
• Mounts: Pendant, Ceiling, Wall, Stanchion
• Optics:
• Fluted Globe - with or without Reflectors
• Clear Globe (Exclusive) - with or w/out Reflectors
• Maximum Lumens
Fluted Globe, Ceiling
Lighting
EML Series
Accessories
• Reflectors
• Explosion Proof Photocells
Fluted Globe, Ceiling
Lighting
Lighting
KFLC Compact LED FLOOD
Applications
 Narrow Walkways , handrails
 Uses KF mounts
Lighting
KFL LED Flood
• Range 60-195w
• Lumen Packages from
6111 to nearly 22,000
• Ambient Suitability -50 to 55°C
on models up to 195W
• Standard Supplemental Surge
• Stainless steel yoke available
Lighting
KFLH LED
Flood Light
•
Lighting
KFLH High Wattage LED
Flood Light
•
•
•
•
Range 170-390W
21620 – 40410 lumens
Typical Weight 25 lbs
Ambient suitability -40°C to 55°C up to
250 watt
• -50°C for non-hazardous applications
• Trunnion heavy gauge 316 stainless
steel
Lighting
 KFLH UPSIDE DOWN OPTION
Concern snow or dust “build-up”
Lighting
Lighting
Lighting
Lighting
KF1L Class I Div. 1 Flood
KF1L LED Flood
• -50°C to 55°C
• 90W, 105W, 110W, 125W, 150W,
165W & 195W Models
• 15,707 Max Lumens
• 5000°K (Noon Sunlight)
• Uses standard KF HID Mounts
Lighting
KF1L LED Flood
Lighting
Portable LED Floodlight
KFLP Series
 Fixture Ratings
 Class I Div 2 Grps A,BC,D
 Class II Grps E,F,G
 Class III & NEMA3 & 4X
 Available wattages from 60-195
 Stable Handle and Base assembly
 Polycarbonate Lens
 Guard
 Cord and Plug options available

Lighting
Portable LED Floodlight
KFL-STND
 Available option for all Killark Floodlights
 Stable 8 Foot High Mounting
 Polycarbonate Lens
 Guard
 Cord and Plug options available

Lighting
Portable LED Floodlight
KF1LP Series
 Fixture Ratings
 Class I Div 1 Groups B,C,D
 Class II Groups E,F,G
 Class III & Type 4X
 Available wattages from 90-125
 Stable Handle and Base assembly
 Glass Lens
 Guard
 Cord and Plug options available

Lighting
Lighting
Lighting
NFPA 101®, Life Safety Code®

Three Methods of Testing
Functional test
 Monthly 30 Second Test
 Yearly 90 Minute Test
 Fully Operational During Test
 Written Record of Visual Inspection
 Self-Diagnosis
 Automatic Functional
 Written Record of Visual Inspection
 Computer Based
 Automatic Functional
 Report Generated by Computer

Lighting
Non-Metallic Housing
 Functional Self-Testing
 Lithium Iron Phosphate Battery
 Polycarbonate Lens
 NEMA 4X and IP66 Rated
 90 Minute
 Universal Mounting Plate
 I-Beam
 Pole
 Column
 Wall

Lighting
Lighting
Lighting
• 2 heads, attached or remote
• Many Configurations Available
• 3x’s to 5x’s Brighter than competition
• Integral or Remote Push-To-Test
• Available 15 minute Time Delay
Integral PTT
Remote PTT
Lighting
• 13 & 16W
• Same LED/Driver as VSL
• DVL Body can be purchased to upgrade
the 1000’s of existing Incandescent Models
Lighting
Food Processing
Lighting
Food Processing
LOCATION DESCRIPTION
NSF CERTIFICATION
Use and Commentary
Typical Lighting
Applications
Areas where direct contact with food products during normal operations would not be expected.
NON-FOOD Zone
SPLASH ZONE
Kitchens; Food storage; Dry
process areas;
Damp
process
areas - No Drip
There is a concern that the fixture will add contamination to the protected space or food product
Possibility.
(i.e. cleanability - will the finish withstand cleaning, chipping paint, deteriorating paints or finishes,
lens impact resistance, lamp glass breakage, etc.).
Equipment is located outside the normal wash down area.
Areas where direct contact with food products during normal operations would not be expected;
however, the fixture may be situated such that liquids used in the processing or cleaning
procedures, may splash, spill, or otherwise soil - either intentionally or inadvertently - the surface
of the fixture. There then is the potential for dripping or draining onto other surfaces or even the
process. Since these fixtures are often used in wash down areas, a Wet-Location listing is not
sufficient.
Fixtures must be tested to withstand high-pressure hose wash down. The concerns of Non-Food
Zone also apply.
Wet or damp process areas;
High Pressure
purging and/or
decontamination used in the
process; area using hose
wash down.
The concerns of Non-Food Zone also apply.
FOOD ZONE
Areas where direct contact with food products is normally expected and surfaces from which the
food may
drip, drain, or splash back onto surfaces normally in contact with food.
Equipment other than lighting fixtures
typically requires this certification (i.e. work tables, cutting boards, other direct contact
equipment).
Category not typically used
for lighting.
Lighting
Food Processing
USDA Minimum Lighting Requirements
AREA
MEAT
POULTRY
General
30
30
Offal Cooler
30
X
Carcass Coolers
30
X
Freezers
30
X
Dry Storage
30
X
Ante-mortem Inspection
30
30
Suspect Pen Inspection
30
X
Inspection Stations
50
X
Inspection Stations (Traditional)
50
50
Inspection Stations (NELS/SIS/NTI)
X
200
Pre and Post chill Inspection
X
200
Establishment Quality Control Inspection
50
200
Reconditioning and Re-inspection
50
200
All other Areas
20
30
Lighting
Grain Facilities
Lighting
Distillery in Kentucky
Lighting
Fertilizer Plant in Saudi Arabia
Lighting
Oil Refineries
Lighting
Phosphate Facility in Florida
Lighting
Power Plant in Kansas City
Lighting
Food Processing Facility in CA
Lighting
Download