Harsh & hazardous Lighting Products overview Complete Lighting Line Aluminum/Non-Metallic Hostile & Hazardous Location Fluorescent – Linear and Compact HID (HPS & Metal Halide) Induction – Great for cold climates Battery Fluorescent (Emergency) Incandescent Xenon (Signals) LED Industrial General Purpose or C1D2 - C2D1 C1D1 Explosion-Proof Lighting Lighting LAL Series CL l Div. 2, Groups A, B,C,D CL l Zone 2, Groups llC, llB, llA CL ll, Div. 1 & 2, Groups E,F,G AEx nAll, Ex All Wet Locations NEMA 4X, IP66 ABS Pending IECEx Zone 2 and Zone 21 areas Ex nA IIC T6 to T3, Gc Ex tb IIC T95°C Db Tamb -50°C≤Tz≤+65°C, IP66 IECEx Certificate QPS 15.0010 ATEX Certificate CML 15ATEX4081X (nA) CML 15ATEX3082X (tb) Lighting Side-by-Side Killark LAL Pauluhn DLL Rig-A-Lite MHL IP66 IP66 IP66 IP66 IP66 Class 1 Div 2 Groups A,B,C,D A,B,C,D A,B,C,D A,B,C,D A,B,C,D Class 2 Div 1 Groups E,F,G F,G F,G Not Listed E,F,G ~16000 7,100 7,654 4380 @ 6500 K 7,000 On Chassis Separate box Only Mentioned - On Chassis N/A 50 feet - - N/A -20°C to 50°C -20°C to 50°C - - -20°C to 65°C up to 149 130 up to 102 IP Rating Lumens Emergency Max Distance from fixture Emergency operating temperatures Lumens per watt Rated Life 60,000 Warranty 5 years Crouse Hinds LL48 Dialight SafeSite 106 Temp code 40°C T6 T6 T4A T5 T5 Temp code 55°C T5 T5 T4A T4A - Temp code 65°C T5 T5 T4A Not Listed - 2 foot weight ~19 12.5 10 - - 4 foot weight ~28 22.5 18 - - Lighting LED vs Fluorescent Much Higher L/W = Lower Energy Costs Lighting LZ2NL – LZ2SL Linear LED • 2’ and 4’ models - 18W to 120W • 2500 - 16000 Lumens • 130 to 150 Lumens per Watt • Ambient Sustainability -40°C to 55°C • LED Array Life up to 212,000 Maintenance Free Hours • Crisp White 5000 Kelvin Light (Noon Sunlight) • Thermal Shock and Impact Resistant Polycarbonate Lens Lighting HLLX Series Lighting • Class I Division I • Wet Location Listed • NEMA 3, 4X, 7(C,D), 9(E,F,G) • Suitable for Wet Locations • Suitable for Paint Spray Booths • Factory Sealed Lighting Lighting MBL SERIES Wattage Range 14 – 50W New Flat Lens Optics (to 25W) Flat: Polycarbonate or Glass Lighting MBL Series Flat Lens LED Very Compact Size – Ideal for: > Tunnels – low ceiling or narrow passage > Walkway lighting from handrails > Variety of aiming possibilities Patent Pending Lighting MBL2530 Flat Lens LED • • • • • • • Flat Lens 14 - 25W Class I Div. 2; Class II Div 1; N4X Pendant, Ceiling, Wall, Stanchion Ceiling Mount Can be “Side mounted” for minimum Depth --- Good for very low ceilings or narrow corridors/tunnels --- Only 7-3/8” deep w/ ceiling mount Options: • “Wallwash” Glare Guard (similar to a mini Wallpack) • Wire Guard Shown with “Pathway” reflector on Ceiling Mount To Wall Lighting VM1L Series • Wattage Range: 40W, 45W, 50W • Maintains all CertiLite®V Features including • 8 Mounts: Pendant, Ceiling, Wall, Cone Top 25° Stanchion, 90° Stanchion (Straight) EZ Adapter, Tank Adapter • Multiple Optics and Reflectors • “Earthquake Tab” for Optional Safety Cable • Factory mounted photocell Option • Backward compatibility with CertiLite® VM mounts as old as 40+ years – Users can “GREEN” UP to the Latest Technology for Hostile or Hazardous Environments Lighting Key Exclusive Feature Swing Barrel-Nut • • • • • • Stainless Steel Connection Take the “Load Off” for the installer Just hang and tighten Ordinary screwdriver Saves Time and Labor Backward Compatibility With Old VM Lighting VM1L Series • 8 Mounts: Pendant, Ceiling, Wall, Cone Top 25° Stanchion, 90° Stanchion (Straight) EZ Adapter, Tank Adapter • Ceiling mount available in 4 or 5 Hub models • 5-hub often utilized for tunnels as temporary lighting • Center Hub Hangs, Side Hubs Feed • Sizes: ¾”, 1”, M20 Lighting Tank Adapters Allows Killark Fixtures to be mounted directly to competitions splice boxes. • Especially helpful for ceiling or wall mounts where there is incoming and outgoing conduit • Upgrade from Mercury etc. to GREEN Technology Other Adapters Available • Crouse® Deep – 70’s Wall • Appleton® MercMaster ®II • Appleton®MercMaster ® III • Hazlux®3 • Holophane® Ceiling • Petrolux®2 • GE® Lighting VM1L Series • Multiple Optics include • Globes, with or without Dome or Angle Reflectors • All-Glass Type V (minimizes Hot Spots) • Spin-Top Refractors Type V in 8” and 12” • Guards for all of the above Type V Refractor Even Pattern Focused Out & Downwards Lighting VM1L Series Accessories – Options • Fuses, Terminal Blocks, Assembly of Mount & Optic • Reflectors, Exit Sign Lighting VM4L IECEx Ex nA IIC T4, Gc Ex tb IIIC T83°C Db Tamb -40°C≤Ta≤+65°C, IP66 QPS 15.00006 Lighting 2011 Heat Sinks K C A Late 2012 – 2013 Heat Sinks K ? C A Lighting Concave Bulb > Two Constructions: Concave and Bulb; Same Wattage = same $ > Pricing moves based on L/W Performance, not wattage > C has less GLARE, but less Lumens; B has more Lumens, but more Glare Lighting Many choices: • Concave or Bulb LED Array • Mounts • Optics Flat Lens will be an option for VM4LC “Concave” Models Lighting EML Series • 40W – 50W LED Explosion-proof • Mounts: Pendant, Ceiling, Wall, Stanchion • Optics: • Fluted Globe - with or without Reflectors • Clear Globe (Exclusive) - with or w/out Reflectors • Maximum Lumens Fluted Globe, Ceiling Lighting EML Series Accessories • Reflectors • Explosion Proof Photocells Fluted Globe, Ceiling Lighting Lighting KFLC Compact LED FLOOD Applications Narrow Walkways , handrails Uses KF mounts Lighting KFL LED Flood • Range 60-195w • Lumen Packages from 6111 to nearly 22,000 • Ambient Suitability -50 to 55°C on models up to 195W • Standard Supplemental Surge • Stainless steel yoke available Lighting KFLH LED Flood Light • Lighting KFLH High Wattage LED Flood Light • • • • Range 170-390W 21620 – 40410 lumens Typical Weight 25 lbs Ambient suitability -40°C to 55°C up to 250 watt • -50°C for non-hazardous applications • Trunnion heavy gauge 316 stainless steel Lighting KFLH UPSIDE DOWN OPTION Concern snow or dust “build-up” Lighting Lighting Lighting Lighting KF1L Class I Div. 1 Flood KF1L LED Flood • -50°C to 55°C • 90W, 105W, 110W, 125W, 150W, 165W & 195W Models • 15,707 Max Lumens • 5000°K (Noon Sunlight) • Uses standard KF HID Mounts Lighting KF1L LED Flood Lighting Portable LED Floodlight KFLP Series Fixture Ratings Class I Div 2 Grps A,BC,D Class II Grps E,F,G Class III & NEMA3 & 4X Available wattages from 60-195 Stable Handle and Base assembly Polycarbonate Lens Guard Cord and Plug options available Lighting Portable LED Floodlight KFL-STND Available option for all Killark Floodlights Stable 8 Foot High Mounting Polycarbonate Lens Guard Cord and Plug options available Lighting Portable LED Floodlight KF1LP Series Fixture Ratings Class I Div 1 Groups B,C,D Class II Groups E,F,G Class III & Type 4X Available wattages from 90-125 Stable Handle and Base assembly Glass Lens Guard Cord and Plug options available Lighting Lighting Lighting NFPA 101®, Life Safety Code® Three Methods of Testing Functional test Monthly 30 Second Test Yearly 90 Minute Test Fully Operational During Test Written Record of Visual Inspection Self-Diagnosis Automatic Functional Written Record of Visual Inspection Computer Based Automatic Functional Report Generated by Computer Lighting Non-Metallic Housing Functional Self-Testing Lithium Iron Phosphate Battery Polycarbonate Lens NEMA 4X and IP66 Rated 90 Minute Universal Mounting Plate I-Beam Pole Column Wall Lighting Lighting Lighting • 2 heads, attached or remote • Many Configurations Available • 3x’s to 5x’s Brighter than competition • Integral or Remote Push-To-Test • Available 15 minute Time Delay Integral PTT Remote PTT Lighting • 13 & 16W • Same LED/Driver as VSL • DVL Body can be purchased to upgrade the 1000’s of existing Incandescent Models Lighting Food Processing Lighting Food Processing LOCATION DESCRIPTION NSF CERTIFICATION Use and Commentary Typical Lighting Applications Areas where direct contact with food products during normal operations would not be expected. NON-FOOD Zone SPLASH ZONE Kitchens; Food storage; Dry process areas; Damp process areas - No Drip There is a concern that the fixture will add contamination to the protected space or food product Possibility. (i.e. cleanability - will the finish withstand cleaning, chipping paint, deteriorating paints or finishes, lens impact resistance, lamp glass breakage, etc.). Equipment is located outside the normal wash down area. Areas where direct contact with food products during normal operations would not be expected; however, the fixture may be situated such that liquids used in the processing or cleaning procedures, may splash, spill, or otherwise soil - either intentionally or inadvertently - the surface of the fixture. There then is the potential for dripping or draining onto other surfaces or even the process. Since these fixtures are often used in wash down areas, a Wet-Location listing is not sufficient. Fixtures must be tested to withstand high-pressure hose wash down. The concerns of Non-Food Zone also apply. Wet or damp process areas; High Pressure purging and/or decontamination used in the process; area using hose wash down. The concerns of Non-Food Zone also apply. FOOD ZONE Areas where direct contact with food products is normally expected and surfaces from which the food may drip, drain, or splash back onto surfaces normally in contact with food. Equipment other than lighting fixtures typically requires this certification (i.e. work tables, cutting boards, other direct contact equipment). Category not typically used for lighting. Lighting Food Processing USDA Minimum Lighting Requirements AREA MEAT POULTRY General 30 30 Offal Cooler 30 X Carcass Coolers 30 X Freezers 30 X Dry Storage 30 X Ante-mortem Inspection 30 30 Suspect Pen Inspection 30 X Inspection Stations 50 X Inspection Stations (Traditional) 50 50 Inspection Stations (NELS/SIS/NTI) X 200 Pre and Post chill Inspection X 200 Establishment Quality Control Inspection 50 200 Reconditioning and Re-inspection 50 200 All other Areas 20 30 Lighting Grain Facilities Lighting Distillery in Kentucky Lighting Fertilizer Plant in Saudi Arabia Lighting Oil Refineries Lighting Phosphate Facility in Florida Lighting Power Plant in Kansas City Lighting Food Processing Facility in CA Lighting