MEASUREMENT and CONTROL

advertisement
BALLAST WATER MANAGEMENT SYSTEM
HEAD OFFICE & FACTORY
MEASUREMENT
and CONTROL
For Shipbuilding & Offshore
GIMHAE FACTORY
HEAD OFFICE & FACTORY
#1559-3, SONGJUNG-DONG, GANGSEO-GU, BUSAN, KOREA
TEL: +82-51-831-1010, FAX: +82-51-831-1399
http : / / www.worldpanasia .com
E-mail : panasia@worldpanasia .com
SALES CENTER
TEL: +82-51-970-1513,
R&D CENTER
TEL: +82-51-970-1537,
DESIGN CENTER
TEL: +82-51-970-1526,
SERVICE CENTER
TEL: +82-51-970-1545,
E-mail : panasia@worldpanasia.com
E-mail : lab@worldpanasia.com
E-mail : design21@worldpanasia.com
E-mail : service@worldpanasia.com
GIMHAE FACTORY / E&C DIVISION
#715-1, YONGDUK-RI, HANLIM-MYUN, GIMHAE-SI, GYEONGNAM, KOREA
TEL:+82-55-310-3300, FAX:+82-55-343-3318
E-mail : enc@worldpanasia.com
BRANCH OFFICE IN CHINA
Rm 2907, 317 Xianxia Rd, Shanghai
TEL : + 86-21-6235-1601~2 (Ext.8002)
Room 6, 29/F, Rm.04-05 Teemtower, Teemall, 208 Tianhe Road,
Tianhe District, Guangzhou, China
Tel : +86-20-2208-1920
C & C PANASIA
1069 Shary Circle, Suite A, Concord, California, U.S.A
Tel : +1-925-265-1003~4
Catalog No.:Measurement & Control V8 Feb. 2010
Company Profile
Since established in 1989, 20 Years of Experience, Partnership & Performance
2000 ~ Present
Aug. 2009 Acquired NET (New Excellent Technology) Certificate
Jun. 2009 Renewed ISO 9001/2008 & Certified ISO 14001/2004
Feb. 2009 Constructed 2nd plant for Environment & Control division at Kimhae city.
Dec. 2008 Submitted an application for Final Approval of GloEn-Patrol Ballast Water Treatment Sys. to IMO MEPC 59 Session
Mar. 2008 Granted Basic Approval of GloEn-Patrol Ballast Water Treatment Sys. from IMO MEPC 57 session
Jan. 2007 Changed company name to PANASIA CO., Ltd
J u l . 2006 Contracted a high efficient DeNox System for IST project in New York
Jun. 2005 Collaborated the technical & marketing division with Endress+Hauser Korea Co., Ltd
Jun. 2004 UL certified for Level switch(PR-30 series) & Level transmitter(CPR-100)
Dec. 2003 Appointed as INNO-BIZ factory from the Government
J u n. 2003 Appointed as a promising exporting company from Export Assistance Center.
May. 2003 Achieved ISO 9001:2000 certificate(DNV).
Sep. 2002 Appointed as Clean Factory from Ministry of Labor.
A p r . 2001 Appointed as Superior Exporting firm from Export Assistance Center.
A p r . 2001 Awarded the prize from the Minister of Science and Technology.
Sep. 2000 Moved to New Factory in Nok-San Industrial Complex.
1989 ~ 1999
J u n. 1999 Opened R & D Laboratory.
J u n. 1998 Appointed as a promising venture company by Korea Electric Power Corp.
J u n. 1998 Achieved ISO 9001 certificate (DNV).
Mar. 1998 Registered Korea Electric Power Corp. as a supplier for Level Instruments for a nuclear power plant.
Nov. 1997 Awarded a prize for "A Proud Korean" by the president of Korea.
May. 1997 Appointed as a promising technical developing company from Government.
Mar. 1997 Awarded the prize of an excellent technical development from Government.
Mar. 1996 Registered as a sub-supplier of STX(Daedong) Shipbuilding Co.,Ltd.
A p r . 1993 Appointed as a localizing manufacturer for Level Instrument by the Korean Government.
Feb. 1993 Awarded the excellent development prize by Hyundai Heavy Ind.Co.,Ltd.
J u n. 1992 Concluded the technical & marketing collaboration agreement with IPH MARINE AUTOMATION A/S in DENMARK.
Mar. 1990 Registered as a sub-supplier of Hyundai Heavy Ind. Co., Ltd.
O c t. 1989 Established PAN-ASIA PRECISION & ENGINEERING Co.,Ltd. as a manufacturer of
Level Instrument in the field of marine industry.
COMPANY PERSPECTIVE
More than 10,000 ships
More than 20 years
PANASIA CO.., LTD. 2
3
The Leader in Measurement &
Control Technology
Long Accumulated Know-How and
Technology are sure of satisfying customer s needs.
Hoping your business to be prosperous continuously, we sincerely appreciate your
cooperation and support since its establishment in 1989.
Despite many setbacks and hardships over the past eighteen years,
We, PANASIA has managed to achieve solid growth by turning crisis into opportunity.
And also grown into one of the leading companies in the field of level measurement &
control technology of marine engineering.
Based on our slogan "Dream & Tomorrow",we have always been motivated by passion
and a willingness to take on any challenge to make the future better.
We will secure world-class level measurement & control technology of marine
engineering and understand changes in the markets and with customers.
Through this we will play a role as a global company that has the market knowledge to
lead our customers. We will continue making innovations and changes.
We ask for your continued interest in PANASIA CO.,LTD
and hope you will keep watching our ever-changing company.
Yours sincerely
President
MARKETING TEAM
DESIGN TEAM
Contents
08
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
41
Radar Beam Type Cargo Tank Monitoring System
Magnetic Float Type Cargo Tank Monitoring System
Magnetic Float Type High & Overfill Alarm System
Acoustic Type High & Overfill Alarm System
Valve Remote Control System
Air Purge Type Tank Level & Draft Gauging System
Electric Pneumatic Type Tank Level & Draft Gauging System
Electric Pneumatic Type Tank Level & Draft Gauging System (Level Pride)
Electric Pneumatic Type Level Transmitter
1:1 Converter (Pneumatic Tank Level Gauge)
Electric Pressure Type Level Transmitter (LEVEL-3000)
Water Ingress Alarm System
Pressure Monitoring System
Vapour Emission Control System
Fixed Gas Detection System
Pump Room Bilge High Level Ararm System
Temperature Monitoring System
42
44
46
48
50
52
56
58
62
63
64
65
Flat Type Glass Level Gauge
Reflex Type Glass Level Gauge
Magnetic Float Type Level Gauge
Self-Powered Contents Gauge
Dial Type Float Level Gauge
Float Type Level Switch
Displacement Type Level Switch
Reed Switch Type Float Level Switch
Electric Indicator
Digital Indicator
Class Approvals
World Wide Service Network
Robert SooTae, Lee
R & D TEAM
SERVICE TEAM
PRODUCTION TEAM
PANASIA CO.., LTD. 4
5
Tank Monitoring System
Product List
01. Cargo monitoring System
Radar Beam Type
Magnetic Float Type
02. High & Overfill alarm system
Magnetic float type
Acoustic type
03. Valve Remote Control System
04. Tank Level & Draft gauging System
Air purge type / Electric pneumatic type
Electric pressure transmitter type
05. Vapor Emission control system
06. Fixed gas detection system
07. Water ingress alarm system
08. Pressure / Temperature monitoring system
09. Bilge high level alarm system
10. Local level gauge / switch
PANASIA CO.., LTD. 6
7
Radar Beam Type
Cargo Tank Monitoring System
Technical data
Application
Level-Radar is used for continuous non-contact level
measurement of liquids in Cargo Tanks and Slop Tanks of
Crude oil carrier, Oil & Chemical Carrier.
The measurement is not affected by changing media,
temperature changes, gas blankets or vapours.
Measuring range
Output
Measuring accuracy
Measuring cycle
Measuring Principle
Certification
Level-Radar is a "downward-looking" measuring system,
operating based on the time-of-flight method.
It measures the distance from the reference point(process
connection)to the product surface.
Radar impulses are emitted by an antenna, reflected off
the product surface and received again by the radar
system.
Product temperature
Pressure
Process connection
Major material
Beam angle
Weight
Emitter
Timer
Receiver
Up to 35m depending on
installation, product, surface
conditions and antenna size
4...20mA, HART PROFIBUS PA,
FOUNDATION Fieldbus.
3mm
1sec
ATEX 1/2 G EEX ia C T6
ATEX 1/2 G EEX d[ia] C T6
-40 to 150
from vacuum to 40 bar.
1 ” thread DN50(2”)
..DN150(6”) flange
SUS316
8
10kg
HAZARDOUS AREA
Principle of Radar-Technology
Generator
Your benefits
2-wire technology, low price.
a real alternative to differential pressure, floats
and displacers. 2-wire technology reduces wiring
costs and allows easy implementation into
existing systems.
Non-Contact measurement:
Measurement is almost independent from
product properties.
Easy on-site operation via menu-driven
alphanumeric display.
Easy commissioning, documentation and
diagnostics via operating Software (ToF Tool)
2 frequency ranges-26GHz :
No compromises, the right frequency for every
application.
HART or PROFIBUS PA respectively
FOUNDATION Fieldbus protocol.
NON-HAZARDOUS AREA
d
t
d=c t
2
PANASIA CO.., LTD. 8
9
Solution for a narrow and small tank
like Slop tank or Residual tank
Advantage of 2 Frequencies
+
mm-accuracy
~26GHz
Increased accuracy.
Small beam angle
Ideal in small vessels.
~ 6GHz
Less effected by turbulent
surface and foam
Less effected by condensate
and build-up
10
-
Size of antenna / beam angle
Levelflex M FMP40
Sensitivity against Build-up,
foam and turbulent surface
3
+
-
ToF Family-Commissioning
Multi-line plain text display.
Removable display for comfortable operation.
Menu-guided operation in national language.
Help for parameter setting.
Display
Commissioning-easy,
fast and safe
Tool
Uniform operation concept.
Graphical support and online help (BA, TI,..)
Documentation of measuring point incl.
envelope curve
Integrated program for tank linearization and
curve calculation of channel measurement
Measuring Precisely and
independent of temperature,
pressure and gas layers
Product density and variation of density
Turbulent surfaces or foam
Wall material of the vessel
Shape of vessel
Obstacles
Technical data
Process media
Measuring range
Output
power supply
Temperature
Certification
Protection
Liquids and solids
35m cable, 4m rod
HART, PROFIBUS PA, FF
2-wire 4...20mA loop powered,
4-wire AC/DC
-40...+150 (pressure up to 40 bar)
ATEX 1/ 2 G,
ATEX 1/ 3 D
IP68
PANASIA CO.., LTD. 10 11
Magnetic Float Type
Cargo Tank Monitoring System
General
Working Principle
The Tank Monitoring System, named as PATROL system is a magnetic float type tank level gauge
featuring an all-in-one detector that measures tank level, temperature,vapor pressure, as well as issuing
alarm when limits are exceeded.
The TANK MONITORING SYSTEM monitors these tank conditions on various display units.
Information on ballast tanks, fuel oil tanks and draft gauges, as well as cargo tanks can be comprehensively
utilized by integrated ship operation control system via a loading computer.
A key feature of the Tank Monitoring System is its ease of handling, because the sensors in the detector are
flexible, it can be lifted up by hand without the need to enter tanks, even in the case of cargo tanks of crude
oil Tanker, Product oil Tanker, chemical carrier for repair and maintenance.
Likewise, transportation and fitting of the Tank Monitoring System is also simple.
For LNG carrier, this magnetic float type tank level gauge is usually provided in W.B.T & Draft gauge
system and F.O tank level gauge system.
Sets of reed switches are positioned along the
length of the guide pipe.
As the float travels up and down the guide
pipe in accordance with the level of the liquid
in the tank,
the flux emitted from magnets within the float
works upon the reed switches ON or OFF.
By measuring voltage across the transmitter
circuit, the level of the liquid can be calculated
according to the changes in circuit resistance.
The converted signal is sent to the control box
via I.S. barrier in the control room or to a local
indicator as the case may be.
Standard Specification
Level Detecting Part
Type
Anti-Explosion Structure
Measuring Range
Read Switch with Magnetic Float
Ex ia C T6
50m, max
Specific Gravity
0.5 and above(of liquid in tank)
Viscosity
15,000sec. Redwood No,1 max.
Detecting Accuracy
Allowable Temperature
Allowable Pressure
20mm (option:10mm)
-60...+150 (stand.), -162 (option)
3kgf /
(option:80kgf/
,max.)
Temperature Detecting Part
Type
Measuring Range
Detecting Accuracy
Two-terminal IC, temp, Transducer
-55/+150
2
System
HAZARDOUS AREA
Local Indicator
SAFETY AREA
Level/Temp./I.G.
Pressure Transmitter
Tank Top
Application
Crude oil
Product oil
Chemicals
Sea Water
Fresh Water
High & Overfill
Alarm Switch
Installation of
Bottom Support
Cargo Monitoring Console
PANASIA CO.., LTD. 12 13
Magnetic Float Type
High & Overfill Alarm System
General Operating Principle
The PANASIA high level alarm sensor consists of magnetic float and reed switch built in guide pipe.
When the magnetic float moves upward with rising level, the hermetically sealed magnetic reed switch inside
the pipe will be de-activated.
This switch will be in an open-state position, which output alarms.
When the magnetic float moves down ward with falling level, the reed switch switch will be activated and will
be in a closed-state position (non alarm position).
This means a normally operated fail to safe loop.The 95% switch is normally for high alarm.
The 98% Switch is normally for high-high alarm(overfill alarm)
A test lever is provided for manually functional test to check integrity of high level alarm system before cargo
loading.
High & Overfill Alarm Switch
Overfill Alarm Switch
Model : PR-30EX-2
Model : PR-30EX-1
Operating Signal
Remark
Cargo Tank High & Overfill Alarm system is throughly designed according to
USCG latest requirements and are to be required by IBC Code
Model:PR-30EXConnection Diagram
Technical Specification
Detection units
Detecting Accuracy
Switch Contact Rating
Specific Gracity
Material
Anti-Ecplosion Structure
Allowable Pressure
Connection Size
Alarm Point
Type approved by
Reed switch with magnetic float
5mm
250VAC, 1A
0.6 above
Housing-SUS316
Flange-SUS304/SUS316
Guide pipe-SUS304/SUS316
Float-SUS316, Titanium
Intrinsically safe type
PR-30EXNumber of float
: 1 float
: 2 floats
6kgf/
Air Horn
Installation-JIS 5K 100A FF/125A FF
JIS 5K 125A FF(with chamber)
Conduit-JIS 5K 32A or JIS 5K 40A
High alarm-at 95%of cargo volume
Over fill alarm-at 98% of cargo volume
KR,ABS,DNV,LRS,BV,GL,NK,RINA
Electric Horn with
Strobe Light
High & Overfill Alarm Unit
Air supply 6~8 bar
PANASIA CO.., LTD. 14 15
Acoustic Type
High & Overfill Alarm System
Remark
Applications
Cargo Tank High & Overfill alarm system is throughly designed according to USCG latest requirements
and are to be required by IBC Code.
High level alarm and Overflow alarm under IBC code, USCG & IMO’s
latest requirement in any type tanks, esecially cargo tanks on chemical
/ product tanker, crude oil carrier.
Features
Maintenance Free
Design of no moving part and simplified structure resulted strong enough and maintenance free product,
which is endurable sloshing wave or exces vibration in the tank.
For all kind of liquid
This equipment is sustainable to all kind of liquid in the tanks, such as crude oil, high viscous bunker oil,
petroleum products, chemical, etc. And no correction is required for the specific gravity.
Check apparatus before loading
Specially designed magnetic circuit is given for the operational check before loading cargo in the tank,
which is required by SOLAS and Federal Rule for Coast Guard.
Tank Pressure Monitoring
Built-in type pressure sensor could be provided additionally in the housing for oil/chemical tanker as option.
Operating Principle
The sensor is based on the principle of distributed acoustic waves in a metal rod.
If the rod is not covered by liquid then the sound waves are dispersed freely without any interference.
When liquid covers the rod then the emission of sound waves is muffled and his interference is picked up
by the sensor and transmitted to the alarm and control panel.
On the alarm and control panel are displayed warning indication lights for set level 95% and alarm 98%signal
when the set or alarm level is reached. The board contains relays which control the audio and visual alarms.
Electrical connection
ELECTRICAL CONNECTION
Technical Specification
Repeatabillty
Output
I.S approval
Protection
Piezo-electrical transducer
Model : PA-LW2
Power supply
Operating temperature
Metalic rod
Flexible Hose
Electrical connection
Acoustic Type Level Switch
Top mounting < 3mm
Side mounting < 1mm
current loop with
Model : PA-LW2
16mA no alarm
6mA alarm
EEX ia IIC T6
IP56
18 to 30V DC
Nominal 24V DC
Ambient -40 to +85
Liquid -40 to +150
2 or 4 wires
Material
Stainless Steel 316L
Weight
0.7k g (with L=100mm)
10
Netural part
Sensitive part
Propagation of acoustic
waves in side the metallic rod
PANASIA CO.., LTD. 16 17
Valve Remote Control System
Introduction
Electric line
hydraulic pressure line
Hydraulic returen line
The AMRI-SEIL / PANASIA VRC system is designed for position indication and electro-hydraulic remote
control of hydraulically actuated valves. The principle of the VRC system is that pressurized oil, generated
by the power pack, is used to open or close the valve by means of the solenoid controlled actuator.
Safety Area
The actuated valves are installed in
safety area. (Ballast and Engine room etc)
Solenoid Valve Rack
Interface Panel
Automation System
Solenoid valves are used to control the
direction of oil flow to each actuators
operated by an electric signal from control
console installed in safety area.
The interface panel consisting of relays,
Power supplier, Converters and Barriers,
etc., is required to communicate between
valves and computerized control system.
Remote operation by the computerized system
Deck Box
Hydraulic Power Pack
Control console & Mimic panel
The deck box controls the functions of
each actuated valve installed in hazardous
areas via explosion proof solenoid valves.
The hydraulic power unit consists of oil tank,
electric motor & hydraulic pump which generates
the required system operating pressure.
Remote operation of the conventional type by the control
console with mimic panel.
Hazardous Area
The actuated valves are installed in
hazardous area. (In-tank and On-deck)
PANASIA CO.., LTD. 18 19
Air Purge Type
Tank Level & Draft Gauging System
Operating Principle
Specification
The operating principle is based on the measuring the hydrostatic head of the liquid by providing constant
low flow of air into a probe (called as sounding pipe) which opens at the tank bottom.
When a light quantity of air (supplied from flow regulator) is discharged through the purge mouth at the tank
bottom, An air pressure corresponding to the liquid level (considering the viscosity) will be built up in the
sounding pipe.
If the specific gravity of the liquid is known and a pressure in the sounding pipe is measured, it is possible to
calculate the distance from the pipe opening to the surface by means of the above expression.
The pressure is read on the indicator graduated scale in meters or volume or percent of full tank.
Type of system
Accuracy
one(1)-Line air purge system
1% of F.S, if drawn scaleindicator calss 0.5
Working temperature
-25 to + 75
(It must be secured that the dew point
of the air lies below Min. Temperature)
Air flow consumption
5 to 50N/min
Operating air pressure rating
4 to 7kg/
Signal pipe
OD 8mm
Valve casing
alloyed brass with protect cover(SUS304)
Pneumatic indicator
Constant flow regulator
Air supply unit
Pressure switch
for alarm(option)
Air purge head
Draft Box
PANASIA CO.., LTD. 20 21
Electric Pneumatic Type
Tank Level & Draft Gauging System
Operating principle
Monitoring Computer
Electric indicator
Analog interface
module
Application
Signal distributor
RS-485
4-20mA
P/I converter
The operating principle is basically the same as the level
measuement of air purge type tank level monitoring system.
But Electric pneumatic type tank level gauging system has
electric reading and P/I Converter that converts pneumatic
input signal to 4-20 mA output signal in addition to air purge
type system.
Ballast tank level measurement.
Draft measurement.
Engine room tank level measurement.
(F.O, D.O, L.O, etc)
Air supply unit
4-20mA
P/I converter
Constant
flow regulator
The upgraded P/I converts is provided to converter an
pneumatic pressure into an electronic signal for remote
display of tank level and draft gauge on CRT and /or
Electric indicator.
Unlike the pneumatic indicator possible to be damaged by
excess-pressure, this P/I converter is free from inlet
excess-pressure without even Gauge saver.
Model : P940
Output current : 4 to 20mA DC,
2-wire system.
Protection against inlet excess-pressure.
Air purge head
Draft Box
PANASIA CO.., LTD. 22 23
Electric Pneumatic Type
Tank Level & Draft Gauging System
Introduction
LEVEL PRIDE
System diagram
Level Pride is specialized on electric pneumatic air purge system. Level Pride is equipped with all the
necessary components such as air supply unit, constant flow Regulator Module(PA-1500), sensor
Module(PAMX-2000)in one module. You need just one module for measuring 10 tanks. If you have more
tanks to monitor, just plugging each other with LAN cable and set the some configuration. One of the Level
Pride module which is configured as master finds all the slave modules connected with and calculates
information automatically.
Features
10 Tank interface without any additional components. (Air purge System)
-Built-in Air supply unit, Constant Flow Regulator Module (PA-1500)
-Sensor Module (PAMX-2000), 12 bit A/D converter.
Various kind of correction function.
-Specific Gravity, Trim & Heeling, Sensor position
-Volume converting according to the Volume table
Various display format of the tank information to the user
Industrial standard serial link and Ethernet link
-10Mbps LAN 1 channel
-RS232/485 1 channel each
Windows based Configuration program for easy setting & calibration
-Module/Ship/Tank/Channel setting
Specification
Type of system
Air supply
System accuracy
CPU
OS
ROM
RAM
Display
Input
Output
Operating temperature
Operating humidity
Dimension
Weight
Electric Power
one-line air purge system
6~10bar, set to 4bar
1% of Full scale
Intel StrongARMTM SA1110-206MHz
Linux for embedded system
16MByte Flash ROM
64MByte SDRAM, PC100
4 20 character VFD (Vacuum Fluorescent Display)
10 air pressure from tanks
2 serials (built - in RS232/485)
1 LAN 10base - T
Analog output (4~20mA, 1~5V)-Option
Dry contact - Option
-10~45 (under dry air condition)
0~80RH
450 350 240(mm)
App. 20kg
85 ~ 250VAC, 50 ~ 60Hz
PANASIA CO.., LTD. 24 25
Electric Pneumatic Type
Level Transmitter
Features
High accuracy
Long term stability
4-20mA Output signal
EEx-version(EEx ia llC T6)
Easy installation
Easy maintenance
Application
Analog
Interface Module
The level transmitter can be used for measuring level
contents in open such as WBT.
F.O TK. in E/R etc. Additionally the level transmitter is
available in Ex ia-version.
It is easy to install in all types of vessels because all of the
parts is in one.
The Electro-pneumatic transmitter has developed focused
on saving on installation cost with best reliability.
Digital
Indicator
Function
OUTPUT
4-20mA
Monitoring
Computer
The principle of operation is based on the measurement of the hydrostatic pressure at the bottom of a tank
where air is injected continously through a sounding pipe.
A pressure corresponding to the level of the liquid will be built up in the sounding pipe.
This pressure will be measured by the transmitter and converted into a 4 to 20mA signal.
Technical data
Output
4-20mA, 2wire system
Load equation
RL (Vcc-10)/22[ ]
e.g.:24V supply
RL<636
Accuracy
20mm from 0 to 10meter level
40mm from 10 to 35meter level
Temperature
stability
-10 ..+70 <=0.5%
for main range
(overall temperture-range)
Power supply
nominal 24V DC
Effect of voltage
variation
Damping
Insulating current
Material
Naval brass
stainless steel
Air supply
clean dry air 4~8bar
Min. pressure
0.5bar above range
Air consumption approx. 30 IN/ h
range 10...30V
zero point 0.005% pro V
span 0.001% pre V
0-200s adjustable
500V
PANASIA CO.., LTD. 26 27
1:1 Converter
(Pneumatic Tank Level Gauge)
Operating Principle
On one side, the diaphragm is affected by the medium in the tank which is to be measured. the pressure by
which the diaphragm is affected is the hydrostatic pressure of the fluid or gaseous medium.
On the other side, the diaphragm is fastened with the pressure converter, forming so a pressure chamber. Via
an air supply and a throttle, measuring air is applied to the pressure chamber where a pressure corresponding
to the hydrostatic pressure of the medium develops. This pressure can be shown by an indicating Instrument.
the pressure on the supply of measuring air must always exceed the highest media pressure.
Excess air is blown out through the nozzle in the center of the pressure converter.
To avoid distortion, the flange must be fastened at least 4points before final welding. Connecting tubes of
stainless steel or copper are to be used between pressure converter and indicating instrument/air supply.
Technical Data
Measuring range
Air supply
Air consumption
Viscosity
Tolerances
Temperature range
Rasponse time
Air supply
1.4bar
1.4bar
1.4bar
1.4bar
2.4bar
0-30m H2O
1.4bar or minimum 1.2 measuring range
At 1.4 bar air supply approx.30 /h (emth tank, otherwize less
at 2.5 bar air supply approx.40 /h
3500 Redwood 1 sec.
(measured with water)
Including reaction sensivity and hysteresis at 1.4 bar.
at emtpy tank and free discharge nozzle : max.25mm
>0.1m tank level measured from middle of diaphragm : max. 25mm 0.75%
The O-point drift depends on the pressure loss caused by possible hose / tube
mounted on the discharge nozzle.
-40 to + 200 (4bar)
Depends on tube dimension and tube length from pressure converter to
indicating instrument as well as supply
Internal tube
6mm
6mm
6mm
6mm
6mm
Pipe length
30m
50m
100m
300m
100m
Reponse time
approx.10s
approx.20s
approx.50s
approx.4min
approx.5s
Change in level
55mm/s
55mm/s
55mm/s
55mm/s
55mm/s
Application
Primarily for as an indirect continuous measurement
of level and cubic contents respectively of liquid in
containers and tanks.
Our 1:1 converter is espectaily suitable for hygienic
purposes within the food, beverage and chemical
industries as well as for potable water tanks.
PANASIA CO.., LTD. 28 29
Electric Pressure Type
Level Transmitter (LEVEL-3000)
Tank Contents Transmitter
Connection on junction box
This is a 2-wire 4-20 mA level transmitter consisting of a transducer and an amplifier connected via a 6-core
vented cable. The transducer is a pressure sensitive silicon micro strain gauge sensor mounted in a glass to
metal seal. The sensor is protected by an isolation diaphram, electron beam welded to the transducer housing,
with an oil filling between the sensor and the diaphragm. Pressure changes in the front of the diaphragm will
bring a resistance change in the Wheatstone bridge of the transducer.
This change in the Wheatstone bridge will be transmitted to the amplifier as a change in the electrical signal.
Application
BALLAST TANK REMOTE READING
DRAFT REMOTE READING
HEELING AND TRIM REMOTE READING
FUEL OIL TANK REMOTE READING
WASTE WATER, WELLS, LOCKS, RIVERS ETC.
?'@@(?g
?V40Y?g
?'@@(?g
?V40Y?g
?'@@(?g
?V40Y?g
?'@@(?g
?V40Y?g
?'@@(?g
?V40Y?g
Feature
??
??
??
??
??
'@(?g??
V+Y?g?
??
??
??
??
???
???
??
??
'@(?g?
V+Y?g??
??
??
??
??
??
??
??
??
?
'@(?g?
V+Y?g??
??
??
??
??
??
??
??
??
?
'@(?g?
V+Y?g??
??
??
??
??
??
??
??
??
?
'@(?g?
V+Y?g??
?
??
?
??
?
?
?
?
?
?
?
?
?
?
?
'@(?g?
V+Y?g??
??
??
??
??
??
??
??
??
?
'@(?g?
V+Y?g??
??
??
??
??
??
??
??
??
?
'@(?g?
V+Y?g??
??
??
??
??
??
??
??
??
?
'@(?g?
V+Y?g??
??
??
??
??
PIEZORESISTIVE SENSOR ELEMENT
STAINLESS STEEL/TITANIUM MATERIAL
CONNECTABLE TYPE(CABLE CONNECTION PLUGGABLE)
TEMPERATURE MEASURING WITH PT100(OPTION)
DIRECT OUTPUT TYPE(NO AMPLIFIER BOX)
HIGH MEASURING ACCURACY
HIGH TEMPERATURE STABILITY
NO HYSTERESIS
MARINE CLASS APPROVAL
Technicall specifications
Parameter
Measuring Range
Transducer Type
Non-Linearity
Long Term Stability
Total Error Band
Over Pressure
Burst Pressure
Operating Temperature
0~0.25bar, 0~0.5bar, 0~1bar, 0~2bar, 0~4bar, 0~6bar, 0~25bar, -1~5bar Each span
range is programmable in use calibration kit.
Piezo-Resistive Type Transducer
0.25% @ 20
4~20 mA DC loop
Output
powered 2 wire
Max 0.1% / year
Typically 20.8 mA
Current Limiting
Max. 2.0% @-25 ~ 85
(Programmable)
Built-in Temperature Sensor
Pt100 (Optional)
Min. 3 Transducer Range
Transducer/Transmitter Material
SUS316L / Titanium
Protection Class
>200 bar
IP68 (Fully Submersible)
Ex-Approval
-25 ~ 85 (Option125 )
Ex ia IIC T4
Connection on junction box
Outline / Dimension
??
??
??
??
/Xg?W.?e??
V/X?fW.Y?e?
?V/Xe?W.Yf?
V/X??7H?f?
?N)KC5g?
@@@Hg?
@V'Lg?
?J5?N1g?
W.Y??3L?f?
?W.Ye?V/Xf?
W.Y?fV/X?e?
.Yg?V/?e??
??
??
The Power supply can vary from 10 ~ 38 VDC.
Permissible load resistance is shown graphically below.
Power Supply
PANASIA CO.., LTD. 30 31
Water Ingress Alarm System
This system is designed to detect the presence of water in
the cargo holds and intended for usage on bulk carriers.
The system is in accordance with
Configuration
SOLAS chapter XII/12
IMO Res. MSC. 145(77)
IACS SC 180
The water detectors are installed at a height of 0.5m above inner bottom and another at a height not less than 15% of the
depth of the cargo hold but not more than 2.0m. In any ballast tank forward of the collision bulk head, the detector is
installed at a height not exceeding 10% of the tank capacity. In any dry or void space other than chain locker, any part of
which extends forward of the foremost cargo hold and the volume of which exceeds 0.1% of the ship s maximum
displacement volume, the detector is installed at a height of 0.1m above the deck.
Principle of Operation
Electrode type level switch is suitable for level detection in conductive liquid.
If the electrode comes into contact with the liquid, the A.C current will flow through the liquid and complete the
circuit. This AC current can be amplified and fed into electronic converter in sensor housing that detects
changes in its input current caused by rising medium. this change are converted into a corresponding current
change. If the changes exceeds an adjustable limit value, the output current rises discontinuously to > 3.4mA
The I.S.Barrier/signal converter in alarm panel uses this information to switch isolated contacts.
Feature
No moving part
Reliable
No damage by cargo
Easy to maintenance
Insensitive to cargo solids
PR-30EX
(Float type)
Specification
Certified to
Ex ia
HR-665261
(Rod type)
Major Function
C T6
Ambient temperature -25 ~+70
Liquid temperature -20 ~+70
Pressure
0~5 bar
Housing material
SUS316
Process connection Thread G1-1/4A or Flange.
Protection class IP56, IP65, IP68
Normal voltage
4.6V to 30V DC
Normal current
unswitched < 1mA,
switched > 3.46mA
Pre-alarm at 0.5m
Main alarm at 2m
Fault/malfuncition alarm.
(line monitoring)
Override/interlock function
Automatic cancellation of
override condition
Override indication
Power failure alarm
Power automatic switchover
Lamp/buzzer test
Common alarm
Alarm time delay
Function test in-situ.
Design to minimize
a cost to shipowner
Least cost to retrofit
existing bulk carriers
Measuring voltage AC5V
Max. no-load current 1
Max. short-circuit
Frequency
50kHz
PANASIA CO.., LTD. 32 33
Pressure Monitoring System
General
The pressure monitoring system is designed for cargo tank & manifold pressure monitoring for any number of tanks.
The vapour pressure monitoring system is intended for pressure monitoring of waste return lines.
Computer Monitor
Electric horn with strobe light
The PANASIA pressure transmitter is carefully designed to meet a harsh marine application for the tank pressure
monitoring system in accordance with SOLAS II-2/59 amended in 1996, and vapour pressure monitoring system required
under 46CFR part 39. 20-13 of VECS.
The transmitter is a high quality and accuracy semi-conductor type especially suitabe for the low pressure to be measured.
Operating Principle
RS-485
The transmitter measures the pressure by means of a semi-conductor sensor. Pressure changes in front of the diaphragm
will bring about a resistance change. The change in resistance is linearly proportional to the applied pressure and is
amplified by an integrated electronic amplifier to give an output signal. The electrical signals from the pressure transmitters
on deck are connected to zener barriers in the monitoring cabinet equipped with pressure alarm lamp, buzzer and pressure
indicator in the cargo control room.
4-20mA
SAFETY AREA
Pressure
monitoring panel
Technical Specification
Analog interface
module
Power supply
DC 10-30VDC
Accurcy
0.5% FS
Response time
Barrier
Barrier
4-20mA
0~25bar
Over load pressure
Min.3xFS
Burst pressure
200bar
Output signal
4-20mA
Process Connection
HAZARDOUS AREA
<1ms/10...90% FS
Measuring Range
G1/2A(PF 1/2 )
Approval
KEMA 03ATEX1127
Enclosure
IP65(DIN 43650)
Ambient temperature
-25 ~ +85 (T4)
Medium temperautre
-25 ~ +100 (T4)
PANASIA CO.., LTD. 34 35
Vapour Emission Control System
(O2 Content and Vapour Emission Pressure)
General
Operating Principle
This is a complete system to monitor oxygen gas content and vapour pressure in the waste vapour and
manifold lines from vessels. this system complies with USCG Regulation for Cargo vapour emission control
system for tankers. All necessary parts are intrinsically safe protected.
The system has four(4) sample points and only one sample is directed and monitored individually through selecting valve
at the time. The sampling lines are run from the respective sample point to the panel in a hazardous area. Sampling gas is
purged to a atmosphere. Oxygen sensor is designed for monitoring content from 0 to 25 V%. Indicator in control room
activates High O2 alarm at 8% which was preset and gives audible and visual. Flowsensor fitted on flowmeter monitors
sampling gas low flow and activates alarm when flow rate is under minimum flow level.
Pressure transmitter monitors the pressure in waste vapour and manifold line.
Low and High pressure alarm is set at 10mbar and 120mbar respectively.
Technical Specification
Oxygen Gas & Vapour
Press Detection Cabinet
Main Components
Oxygen sensor
Flow meter
Pressure transmitter
Filter & Selection valve
Annunciator
Digital indicators
Power supply
Air supply
Fuse
Oxygen Sensor
Alarm Points
Set Point
Explosion Proof
Pressure Transmitter
Alarm Points
Set Point
Hydrocarbon Sensor
Vaccum pump
Calibration
115/230 VAC (50-60 Hz)
6-8 bar
10 A
0-25% Volume
1
0-100%
EEx ia IIC T4
200mbar
2
0-100% Full Scale
0-100% LEL n-Butane in air
Oil less carbon vane pump
Test gas from gas bottles
Version
Version
HAZARDOUS AREA
SAFETY AREA
HAZARDOUS AREA
SAFETY AREA
FUNCTION
1.OXYGEN CONTENT DISPLAY
2.HIGH OXYGEN CONTENT ALARM(8%)
3.VAPOR PRESS. MONITORNG
4.VAPOR PERSS.
HIGH ALARM(0.125bar)
LOW ALARM(0.01bar)
PANASIA CO.., LTD. 36 37
Fixed Gas Detection System
P & ID Program
General
The sequential gas sample system is a multi point
gas-sampling unit designed to detect and provide
alarms for the presence of flammable and hydrogen
sulphide gases within the water ballast tanks and
void spaces.
The system is designed to extract a gas sample from
each sample point via sample piping to the analysing
unit where the flammable and hydrogen sulphide gas
content is measured. By using solenoid valves,
the unit provides an effective way of sampling multiple
locations using only one sensor for gas detection.
The system utilises a heavy-duty sample pump to
extract a sample of gas from each of the sample point
locations. The extraction circuit incorporates a flow
sensing device to annunciate a flow failure if the pump
cease to operate or sample lines become blocked.
Solenoid valves are used to select each sampling line
for analysis in a sequential or pre-programmed
sampling sequence. Furthermore, the system is
extendable by adding additional valves, which are
automatically recognised and activated.
Flame arrestors are installed on all sample lines
iaccordance with class regulations.
The system can supply information to the vessels AMS
system via a communications protocol which allows for
a real time flow of information including the current
location being sampled and the gas concentration
level at this location.
Indicators
LCD Display - High Alarm Lamp - Low Alarm Lamp - System Failure Lamp Main/Pre Flow Failure Lamp - Sensor Fault Lamp - Standby & Main Power Supply
The system is designed to provide protection of the following areas : Cargo pump rooms; Cofferdams ; Pipe tunnels ; Ballast
tanks and double bottoms ;Void spaces ; Other empty area’s adjacent to slop tanks.
Additionally, stool tanks and other empty areas adjacent to cargo tanks can be protected.
Specification
220VAC 60Hz
Emergency supply 220VAC 60Hz
No of sample points Up to 48
Sensor No.
Sensor No.1
Sensor No.2
Sensor No.3
Sensor type
Infra-Red
Electrochemical
Electrochemical
Range
0~100% LEL
0~50ppm
0~25% VOL
Sample time per line 60 Seconds
Calibrated Gas
Butane
Hydrogen Sulphide Oxygen
Low alarm trip point & type
10%Rising
5ppm Rising
16% Falling
High alarm trip point & type
30%Rising
10ppm Rising
24% Rising
Main supply
Power shut down
30% LEL
When locating fixed sampling points within ballast tanks, areas where an explosion is most likelyto occur must be assessed.
The risk of explosion is mainly related to the release of cargo vapours through the ballast vents in the top of the tank, during
ballast filling. Hence it is considered sufficient that detection takes place in the upper part of the spaces whengas
concentrations reach detectable levels.
We advise that ballast tank-sampling positions belocated at the top of the tank.
The sampling system extracts gas samples from a maximum of 48 lines and the default sample sequence is to cycle from
channel 1 to 48 and then back to channel 1 again. The time that thesystem samples on a channel can be altered for each
sample line to compensate for varyingsample line lengths.
Flame arrestors are constructed from stainless steel and designed to prevent the propagation of
flames from the analyzing unit if a fire occur within the unit. Flame arrestors are provided as loose
items to avoid any damage to the unit during dispatch.
PANASIA CO.., LTD. 38 39
Pump Room
Bilge High Level Alarm System
Temperature Monitoring System
General
Temperature Monitoring System
IMO MSC-67 issued a safety circular recommending measures to take to prevent explosion in oil tanker
cargo pump room for new and existing tankers. OCIMF also recommends that all pump rooms shoud be
provided with a high level alarm which activates audible and visual alarms.
Operating Principle
Level switch monitors level in bilge well. With rising level, switch gives output signal to alarm panel and
then activates audible and visual alarms.
Computer Monitor
Application
Pump Room Bilge
E/R Bilge
RS-232
PATM-5000 series Module is designed for being integrated in a housing and fully compatible with RTD. thermocouple and
thermister etc,. This module can be supplied as complete or partial system with later additions.
HAZARDOUS AREA
SAFETY AREA
PC-based Programmable Controller
Cpu : 16-bit microprocessor
Memory : Up to 256KB Flash ROM, 256KB SRAM
Operating system : Rom-DOS
Built-in Paradym-31 Runtime Engine
(ADAM-5510/P31 only)
Built-in realtime clock
Built-in Watchdog Timer
3 communication ports supported
(COM 1:RS-232;COM2:RS-485:COM3/Programming
Port:3-wire RS-232)
Distributed DA&C system Based on RS-485
Support master/slave communication
ASCII command/response
2-wire, multidrop RS-485 network
Transmission speeds up to 115.2Kbps
7-channel Thermocouplelnput Module
16-bit resolution
7 differential input channels
Software configurable for T/C, mV, mA input
3000 VDC isolation
External cold junction compensation
3-channel RTD Input Module
16-bit resolution
3 RTD input channels
software configurable for Pt or Ni RTD input
Input connection:2,3 or 4wires
PANASIA CO.., LTD. 40 41
Flat Type Glass Level Gauge
PA-FLG-P100 Series
PA-FLG-P100
The PANASIA Flat type level gauge is designed according to JIS standard
specifications. This type level gauge is used for marine oil tanks,excluding
those of flash point of 60 below. Flat type level gauge allow an excellent
observation of colorless liquid level through reflection of several parallel
grooved glass.
A-TYPE (AIR VENT)
B-TYPE (TANK RETURN)
C-TYPE (SELF-CLOSING)
Gauge Body
Water space
Steam/gas space
Gauge glass
Light ray
Light ray
Installation
Operating principle
The principle of reflex glass is based on the difference in the refractive indices of liquid and gas or in particular
of water and steam.. The liquid column is contained within the recess of the centre-piece behind the gauge
glass which is clamped within the gauge body. If a ray of light encounters the surface of one of the 45
slanted grooves in the gas or steam space. It is reflected to the opposite surface of the groove and from there
totally reflected-back into the direction of observation.
The steam or gas space therefore appears as silver-white.
The gauge glass has prismatic right angled grooves, On the side facing the water and steam spaces. Light
rays entering from outside the gauge are either absorbed or reflected depending upon whether they enter the
water or steam space.
The light ray which encounters the surface of a groove in the liquid space is almost totally absorbed.
The liquid behind the reflex glass therefore appears back.
Model Classification and Specification
JIS Code
PA-FLG-P100
Valve type Connection Design
Type
size
pressure
Upper Lower
JIS
Top
selfA
vent closing 5K20A, 3 /
25A
JIS
selfTank
B
3 /
5K20A,
closing
return
25A
JIS
self
selfC
closing closing 5K20A, 3 /
25A
SECTION A = A
Max.
temp’
Valve
Material
channel Glass
150
BC6
SUS304 Borosilicate
150
BC6
SUS304 Borosilicate
150
BC6
SUS304 Borosilicate
Center to
center
275
~
5100
(m/m)
CAUTION
Support bracket to be placed and
spaced Max. 1000mm between upper
and lower valve.
The level gauges shall be classified into three type A,B,C according to the shape of the upper body
Please contact our factory if other specification are required.
PANASIA CO.., LTD. 42 43
Reflex Type Glass Level Gauge
PA-RLG-P100 Series
The PANASIA reflex type level gauge consists of a sturdily constructed body, glass and cover securely fixed
by u-bolts to endure high pressure.
This type level gauge feature serveral parallel grooves cut into the glass surface that is in contact with liquid.
Thus the level of even transparent liquid can be clearly observed.
PA-RLG-P100
PA-RLG-P100
SELF-CLOSING
PA-TLG-P100
BALL CHECK
Model Classification and Specification
Model
PA-RLGP100
PA-TLGP100
Type
A
Valve type
Connection Design
size
pressure
Upper Lower
Ball
Ball
B
Self
Self
A
Ball
Ball
B
Self
Self
Max.
temp’
Material
Valve
Front
Back
channel channel
Center to
center
SUS304 SUS304 SUS304
ANSI 1
150#
20 /
ANSI 1
150#
20 /
200
SUS304 SUS304 SUS304
SUS304 SUS304 SUS304
200
320
~
2870
(m/m)
SUS304 SUS304 SUS304
The level gauges shall be classified into three type A,B,C according to the shape of the upper body.
Please contact our factory if other specification are required.
PANASIA CO.., LTD. 44 45
Magnetic Float Type
Level Gauge
Operating principle
The measuring pipe (chamber) is connected to the tank to form a float chamber that has the same level as
the tank. A float with a built-in magnetic floats freely on the surface of the liquid and transmits its movement
in the pipe, without physical contact, to an externally mounted indicating strip (Indicator).
The indication strip is placed on the ou side of the pipe and consists of numerous magnetic flaps which are
white on one side and red on the other, As the float passes the red/white flaps, the flaps are one after the
other turned 180 around their own axis.
The flaps change from white to red with rising level and from red to white with falling level.
The magnetic level gauge is particular advantage wherever dangerous and toxic media calling for careful
level monitoring.
Features
No harms to the environment. Safety Guarantee.
No leakage to atmosphere
No maintenance costs
Easy to read.
Suitable for pressure tank
Alarm contacts.(option)
Analogue output signal, 4-20mA.(option)
Model Classification and Specification
Working condition
Symbol Mounting Connection Measuring
range
size
type
Temp.
Press.
PLG-65MS
- -
Side
Max.
JIS 5K 25A
5000mm
PLG-65MT
- -
Top
JIS 5K100A Max.
or 125A 2500mm
5 /
200
PLG-65H
Side
Max.
2500mm
50 /
300
5K 25A
5 /
200
Material
Float
rotor
PolyOver 0.8 +/-10m/m SUS304 SUS304 carbonate
resin
PolyOver 0.85 +/-10m/m SUS304 SUS304 carbonate
resin
PolyOver 0.85 +/-10m/m SUS304 SUS304 carbonate
resin
Specific
Gravity
Accuracy
Chamber
rotor columnn
Aluminum
Aluminum
Aluminum
Level Switch Unit and Level Transmitter Specification (Option)
Description of model
PLG-65
Level Transmitter
T :Output 4~20mA
TR :Output 1
S :Level switch
Mounting Type
MS :Side mounting
MT :Top mounting
H :High pressure/ temperature
Material
No of
Housing Transmitter point
Nax.
Measuring working
ranger
temp.
Enclosure
Description Module
Output
Contact
rating
Contact
form
Power
source
Accuracy
Level
switch unit
Dry
contact
125VAC,
0.5A
SPST,
SPDT
N/A
+/-5m/m
AC
N/A
Max.6
N/A
120
Weather
proof
N/A
N/A
DC 24V
+/-% of
F.S
AC
SUS304
N/A
400m/m~
5000m/m
120
Weather
proof
Reed
switch
Reed
4~20mA
Level
and
DC
switch unit switch
resistor Two-wire
These switch unit and transmitter may be used for intrinsically safe application in hazard when connected through
approved zener barriers (Exia llc T4)
Please contact our factory if other specifications are required.
PANASIA CO.., LTD. 46 47
Self-Powered Contents Gauge
PCG-150 Series
General
The PANASIA PCG-150 Series tank contents gauge requires no external power source for operation.
The instrument is completely automatic and provides continuous indication of tank contents without the aid
of batteries or hand pumps.
This gauge unit is simply composed of Diaphragm, capillary tube and dial type indicator.
FOR HIGH VISCOSITY FLUID
(PCG-150V)
FOR LOW VISCOSITY FLUID
(PCG-150S)
FOR HIGH VISCOSITY FLUID
(PCG-150F)
Application
Generally applied to fresh water, Lub oil, Diesel oil, Heavy
fuel oil and solvent gasoil and noncorrosive liquid.
Model:PCG-150 Series
Specifiation
Gauge size
Dial
Mounting type
100,
160
Side, submersible mounting
scale of indication
Height(m) & volume( )
Accuracy
Operating temperature
range
Enclosure
150,
1.5% of full scale
-20
to +100
Weather proof
Min, 100% of full scale
5 meters, 2 meters
Length of capillary tube
(standard), other(option)
Overload
SUBMERSIBLE TYPE
CONTENT GAUGE
Operating principle
The diaphragm is affected by the hydrostatic head medium column in tank, which apply pressure to the oil
filled capillary.
The pressure applied to capillary expands bourdon tube of indicator, so that the indicator displays the level
corresponding to actual tank level.
Description of model
PCG -
??
?@@@@@@@@@@@@@@@@@@@@@??
?@@@@@@@@@@@@@@@@@@@@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@@@@@@@@@@@@@@@@@@@@?
?@@@@@@@@@@@@@@@@@@@@@?
?
??
?@@@@@@@@@@@@@@@@@@@@@??
?@@@@@@@@@@@@@@@@@@@@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@@@@@@@@@@@@@@@@@@@@?
?@@@@@@@@@@@@@@@@@@@@@?
?
Type of sensor connection
S : Socket connenction
F : flange connection
V : lsolating valve connection
GAUGE SEAT
Size of Indicator
MS : 100 dial gauge
MT : 150 dial gauge
Note
Dimension H must be complied with because the
indicator is sensitive to its mounting position.
PANASIA CO.., LTD. 48 49
Dial Type Float Level Gauge
PDG-150 Series
Operating principle
The PANASIA dial type float level gauge consists of float, measuring steel wire and indicating unit as main
components.
A float accurately follows liquid level variations in the vertical direction (horizontal movement of the float is well
restricted by guide pipe).
Vertical movement of the float is transmitted throught a measuring wire to the indicating unit, in which the
measuring wire is wound around a tape pulley kept under constant torque by constant spring.
the vertical movement is converted into rotation of the tape pulley in this way.
This rotation is transmitted through a gear system to an indicator pointer which reads the liquid level on a scale
dial of indicating unit.
CASE-1
DIMENSION
CASE-2
CASE-3
Application
Generally applied to Water tank and L.O, D.O and
H.F.O.tanks.
Besides, magnetic coupling type dial float level gauge
is applicable to the liquids that emits corrosive,
inflammable or poisonous gases.
Model : PDG-150 Series
Model Classification and Specification
Type
Measuring Indication Specific Accuracy
Model Mounting
type
range
system
gravity
PDG150SC-T
PDGDirect
connection 150SW-T
PDGtype
150SW-S
PDG150SC-S
PDGMagnetic 150SI-T
coupling
PDGtype(indirect 150SI-S
type)
Working condition
Temp.
Press.
Material
G/G head
Tape
Float
Guide pipe
Top(with
chamber)
Top(with
guide wire)
Top(with
guide wire)
Top(with
chamber)
0~5m
One-Point 0.7~1.5
15m/m
150
0.2 /
AC
SUS304 SUS304
N/A
0~5m
One-Point 0.7~1.5
15m/m
150
0.2 /
AC
SUS304 SUS304
N/A
0~5m
One-Point 0.7~1.5
15m/m
150
0.2 /
AC
SUS304 SUS304
N/A
0~5m
One-Point 0.7~1.5
15m/m
150
0.2 /
AC
SUS304 SUS304
N/A
Top
0~5m
One-Point 0.65~1.5
15m/m
150
2 /
AC
SUS304 SUS316 SUS316
Side
0~5m
One-Point 0.65~1.5
15m/m
150
2 /
AC
SUS304 SUS316 SUS316
Please contact our factory if other conditions are required
PANASIA CO.., LTD. 50 51
Float Type Level Switch
Operating principle
PANASIA magnetic float level switchs monitor and control liquid levels in open or closed tank.
A permanent magnet is part of a float which rises or falls with the changing liquid level.
This magnet repells another magnet located opposite in the switch housing. In this way it causes a snap action
contact effect. A switch unit provides on-off contacts.
Features
Easy maintenance
Safe operating conditions
Reliable
Test Device
Housing
Megnet
PM-12H
PM-12H-T
PM-12H-E
PM-12H-S
PM-12H-D
PM-12H-C
Float
Application
Fresh water tank, Heavy fuel oil tank.
D.O.tank, Sludge tank, Sewage tank, etc.
switch unit
Technical data
Contact
electrical microswitch,
change contact, SPDT, DPDT
Switch rating
250V AC, 3A
Liquid density
min. 0.7kg/d
Switch hysteresis
20mm height at 0.9kg/d
specific weight
Ambient temperature
-30 to +70
Medium temperature
-25 to +135
Rated Pressure
Installation
PM- 12
??
?
?@@@@@@@@@@@@@@@@@@@@@?
?@@@@@@@@@@@@@@@@@@@@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@@@@@@@@@@@@@@@@@@@@?
?@@@@@@@@@@@@@@@@@@@@@??
-
??
?
?@@@@@@@@@@@@@@@@@@@@@?
?@@@@@@@@@@@@@@@@@@@@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@@@@@@@@@@@@@@@@@@@@?
?@@@@@@@@@@@@@@@@@@@@@??
Option
T : Test Device
C : Cranked
E : Explosion Proof
S : Submersible
D : Differential
H : Horizontal mounting
V : vertical Mounting
3kg/ (standard),
up to 12kg/ (option)
horizontal
Protection of Switch housing IP 56, IP 68(option)
Float material
Flange, housing
sus 316L
SUS 304, ALDC 8
A(ROD LENGTh) : MAX.500MM
B(DIFFERENTIAL) : MAX.300MM
PANASIA CO.., LTD. 52 53
Float Type Level Switch
Operating principle
PANASIA magnetic float level switchs monitor and control liquid
levels in open or closed tank. A permanent magnet is part of a float
which rises or falls with the changing liquid level.
This magnet repells another magnet located opposite in the switch
housing. In this way it causes a snap action contact effect.
A switch unit provides on-off contacts.
PM-12V
PM-12V-T
PM-12V-E
PM-12V-S
Features
Easy maintenance
Safed operating conditions
Reliable
Housing
Switch Unit
Application
Fresh water tank, Heavy fuel oil tank.
D.O.tank, Sludge tank, Sewage tank, etc.
PM- 12
??
?
?@@@@@@@@@@@@@@@@@@@@@?
?@@@@@@@@@@@@@@@@@@@@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@@@@@@@@@@@@@@@@@@@@?
?@@@@@@@@@@@@@@@@@@@@@?
?
-
??
?
?@@@@@@@@@@@@@@@@@@@@@?
?@@@@@@@@@@@@@@@@@@@@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@@@@@@@@@@@@@@@@@@@@?
?@@@@@@@@@@@@@@@@@@@@@?
?
Option
T : Test Device
C : Cranked
E : Explosion Proof
S : Submersible
D : Differential
Magent
Float
H : Horizontal mounting
V : vertical Mounting
Technical data
Contact
PM-12V-D
electrical microswitch,
change contact, SPDT
Switch rating
250V AC ~3A
Liquid density
min. 0.7kg/d
Switch hysteresis
Ambient temperature
20mm height at 0.9kg/d
specific weight
-30 to +70
Rated Pressure
Medium temperature
Installation
Protection of Switch housing
Float material
Flange, housing
3kg/ (standard),
up to 12kg/ (option)
-25 to +135
horizontal
IP 56, IP 68(option)
SUS 316L
SUS 304, ALDC 8
PANASIA CO.., LTD. 54 55
Displacement Type
Level Switch
Operating principle
PM - 90-1
Operation is based upon a buoyancy principle whereby a spring is loaded with weighted displacers which are
heavier than the liquid.
Immersion of the displacers in the liquid results in a buoyancy force change, which moves the spring upward.
Since the spring moves only when the level moves on a displacer, Spring movement is always a small
fraction of the level travel between displacers. A magnetic sleeve is connected to the spring and operates
within a non-magnetic barrier tube. Spring movement causes the magnetic sleeve to attract a pivoted
magnet, actuating a switch located outside the barrier tube.
Switch set points are achieved by moving displacer modules up or down the displacer wire/rod.
PM - 90-2
(VIEW “A”)
(VIEW “A”)
(OPERATING SIGNAL)
Description of model
(OPERATING SIGNAL)
PM - 90
??
?
?@@@@@@@@@@@@@@@@@@@@@?
?@@@@@@@@@@@@@@@@@@@@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@@@@@@@@@@@@@@@@@@@@?
?@@@@@@@@@@@@@@@@@@@@@??
-
??
?
?@@@@@@@@@@@@@@@@@@@@@?
?@@@@@@@@@@@@@@@@@@@@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@@@@@@@@@@@@@@@@@@@@?
?@@@@@@@@@@@@@@@@@@@@@??
1 : Displacer
2 : Displacer
3 : Displacer
T : With Test Device
PM - 90-3
(OPERATING SIGNAL)
(VIEW “A”)
Specification
Model
Max. Max. Setting Mounting Min.
Application Press. Temp. accuracy flange Sp.Gr.
Connection Cable
gland
( / ) ( )
( ) (standard)
High or
PM - 90 T-1 Low alarm
or control
10
180
10
High or
PM - 90 T-2 Low alarm
or control
10
180
10
High alarm
/Mid.
low control
10
180
10
PM - 90 T-3
0.85
JIS
5K 80A
5K 100A 0.85
10K 80A
10K 100A
0.85
Material
Switch
contact
rating Housing Flange Displacer Chamber
Top
flage
15/ 20
a,b,c
250V
AC,
5A
AC
IP56
SS400 SUS304 SS400
or
or
78,
SUS304 200L SUS304
Top
flage
15/ 20
a,b,c
250V
AC,
5AX2
AC
IP56
SS400 SUS304 SS400
or
or
78,
SUS304 200L SUS304
Top
flage
15/ 20
a,b,c
250V
AC,
5AX2
AC
IP56
SS400 SUS304 SS400
or
or
78,
SUS304 200L SUS304
Optional informations
1.Special material(SUS316, SUS304) for weted parts including mounting flange, chamber is also available on
request.
2.Switch contact type : SPDT, DPDT
MODES
DIFFERENTIAL
(mm) 1
CONTACT
CONFIGURATION
PM-90-1
Upper :30 to 50
Lower :30 to 50
NO
COM
NC
PM-90-2
Upper :30 to 50
Lower :30 to 50
NO
COM
NC
NO1
COM1
NC1
PM-90-3
Upper :30 to 50
Lower:200 to 4500
NO
COM
NC
NO1
COM1
NC1
NO2
COM2
NC2
1:Differential is the allowable range from the
acutating level of the switch to the reset level
PANASIA CO.., LTD. 56 57
Reed Switch Type
Float Level Switch
Operating principle
The reed switch type float level switches consist of a
magnetic float and reed switch as main components.
A float equipped with permanent magnet moves up and
down with the fluid level between two stoppers and its
magnetic field actuates a hermetically sealed reed switch
incorporated in guide pipe.
The switches can be normally open, normally closed or
change-over contacts.
The advantage of this principle;there is only one moving part,
the float.
This actuates the reed switch with its magnetic field without
causing any wear.
The reed switch is itself totally isolated from the media.
These advantages give the user safe, repeatable, accurate
and high operational reliability with low maintenance over a
long and trouble free life.
PR-30S-2
(OPERATING SIGNAL)
Technical data
Operating temperature
Design pressure
Process medium S.G.
IP rating
Protection type
Switch output
Switch rating
Float
Flange
Guide pipe
Housing
Material
PR-30S-2 (with chamber)
Application
-Fresh water
-Sea water
-Low viscosity liquids
-20 ~ 100
5kg/ ( 50float), 8kg/ ( 65 float above)
0.6~1.025
IP65, IP66, IP67, IP68
EX ia IIC T6 for PR-30EX
and EX d IIC T6 for PR-30EXD
SPST, SPDT, DPDT(option)
1.2A 200VDC(SPST), 2.5A 250VDC
(SPST), 1A 200VDC(SPDT).
sus 316
sus 304
sus 304
ALDC 8, sus 304
PR-30S (with test device)
Description of Model
PR- 30S
??
?
?@@@@@@@@@@@@@@@@@@@@@?
?@@@@@@@@@@@@@@@@@@@@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@@@@@@@@@@@@@@@@@@@@?
?@@@@@@@@@@@@@@@@@@@@@??
-
??
?
?@@@@@@@@@@@@@@@@@@@@@?
?@@@@@@@@@@@@@@@@@@@@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@@@@@@@@@@@@@@@@@@@@?
?@@@@@@@@@@@@@@@@@@@@@??
C
N
S
I
: With chamber
: No housing
: Submergible type
: Interface Detector
Q’ Ty of float
1 : 1 Float
2 : 2 Float
3 : 3 Float
PR- 30EXD
??
?
?@@@@@@@@@@@@@@@@@@@@@?
?@@@@@@@@@@@@@@@@@@@@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@@@@@@@@@@@@@@@@@@@@?
?@@@@@@@@@@@@@@@@@@@@@??
-
??
?
?@@@@@@@@@@@@@@@@@@@@@?
?@@@@@@@@@@@@@@@@@@@@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@?
@@?
?@@@@@@@@@@@@@@@@@@@@@?
?@@@@@@@@@@@@@@@@@@@@@??
C
N
S
I
: With chamber
: No housing
: Submergible type
: Interface Detector
Q’ Ty of float
1 : 1 Float
2 : 2 Float
3 : 3 Float
CONTACT TYPE : SPDT
All switches have three electric connections(black, blue,red)
The black wire is the common pole for both switching
functions (black contact and make contact)
CONTACT TYPE : DPDT
This switch has two(2) SPDTcontact which is same as above.
PANASIA CO.., LTD. 58 59
Reed Switch Type
Float Level Switch
Contact Protection Requirements
PR-30EXD-1
PR-30S-1N
PR-30S-2N
When switching inductive loads such as relays, solenoids and transformers, reed switch contents require protection in order
to ensure long, dependable life. when current is interruped, the inductance or electrical inertia of the load generates a large
frequency voltage, which appears across the switch contacts. If the voltage is large enough, it can break down the medium
in the gap between them, making a conductive path. this phenomenon, called arcing is the spark you see.
Arcing can cause the contacts to burn, weld together or stick; thus, giving unreliable performance.
The purpose of protection circuits is to prevent arcing, by shorting this voltage through an alternate path.
Recommended Protection
D.C.
A 1N4004 diode(or equivalent) connected cathode-to-positive, as shown in Figure 1, is recommended.
The diode does not conduct when the load is energized, but conduts and shorts out the generated voltage when the switch
opens. The generated voltage always acts in series with the applied voltage.
A.C.
A resistor and capacitor, connected in parallel with the switch, as shown in Figure 2, is recommended. The capacitor is a
hight impedance to 60hertz, but is essentially a short circuit high prequencies of generated voltages.
Transient suppressors or varistors may also be used to dissipate the transient and protect the switch contacts. For
130VAC rated devices, the following table may be used for selection.
Flgure 1
D.C Contact
Protection
(Drain the load)
Drain the Load
PR-30S-1C (With chamber /IP67)
Flgure 2
A.C Contact
Protection
(Protect the s/w)
Protection switch
PANASIA CO.., LTD. 60 61
Digital Indicator
Electric Indicator
Bargraph Type
Electric Indicator
Specifications
Model
Size
Mounting method
Input
Internal resistance
Accuracy
Measuring range
Indicating angle
Weight
Operating temperature
Color
Application
Specifications
Model
Accuracy
Scale
Height
Volume
PAI-100A
110X110 Square
Panel front mounting
DC 4~20mA
1.5
1.5% F.SAT 20
0~100%(Standard)
250deg.
450g
0 to +40
Black
Panel and local gauge box
Contact
Finish Color
Application
Dimension
SK-130-C
30 X 100
Panel front mounting
DC 4~20mA
1.0%
100mm
Resin
Approx. 1.3kg
On-alarm type, offalarm Type
available for special specification
Black or white
Panel and local gauge box
Specifications
Input Signal
Range
Power Supply
Accuracy
Ambient Temp
Model
Weight
Setting Press
DC 4~20mA
-0.1~+0.3bar(Free Scale)
DC 24V
DISPLAY ONLY(SENSOSR : 0.3% of F.S)
-0 ~50
ESDB4
250g
High press : +0.22 bar, Low press : -0.05 bar
Input
Specifications
Model
Size
Mounting method
Input
Accuracy
Scale length
Case material
Weight
Digit
Output
Alarm point
HH
H
L
LL
Material
Power
Temperature
Weight
PAI-4000(Vertical type)
1% of F.S
%Display dual mode.(level & volume)
%Display
Max. 16 Gradient %Display
A) DC 4~20mA(1-5V) or variable resistance
B) RS-485
4Digit
Alarm contact, RS485
2point, 4point (option)
Dry contact normal open or close (option)
Dry contact normal open or close
Dry contact normal open or close
Dry contact normal open or close (option)
ABS
DC24V, 6W(MAX.)
0 ~50
1.0kg
Digital Indicator
Dimension
PANASIA CO.., LTD. 62 63
Class Approvals
World Wide Service Network
Maintenace / Parts Supply / Repaire / Technical Support
Products
CLASS
Classification
Society
KRS
ABS
BV
DNV
LRS
NK
GL
RINA
CCS
RADAR BEAM TYPE
CARGO MONITORING SYSTEM
MAGNETIC FLOAT TYPE
CARGO MONITORING SYSTEM
HIGH & OVERFILL
ALARM SYSTEM
VALVE REMOTE
CONTROL SYSTEM
AIR PURGE TYPE /
ELECTRIC PNEUMATIC TYPE
LEVEL GAUGING SYSTEM
ELECTRIC PRESSURE TYPE
LEVEL TRANSMITTER
AMERICA
New Jersey
Houston, Taxas
Rio De Janeiro, Brazil
WATER INGRESS ALARM
SYSTEM
LEVEL GAUGE
-Self power content gauge
-Flat type glass level gauge
-Magnetic float type level gauge
LEVEL SWITCHES
-PM-12 Series
-PM-90 Series
-PR-30 Series
>>
EUROPE
RY, Denmark
Rotterdam, The Netherlands
Surrey, England
Genova, Italy
Piraeus, Greece
Istanbul, Turkey
Lisbon, Portugal
Limmasol, Cyprus
Vladivostok, Russia