NEMA Contactors and Motor Starters

advertisement
371-2014_QuarkCatalogTempNew 8/1/14 5:57 PM Page 371
4
NEMA Contactors and Motor Starters
MOTOR CONTROLS,
DRIVES & CONTACTORS
NEMA Combination Motor Starters
Features:
Long-Lasting, Energy Efficient Red-ON and/or Green-OFF LED Pilot Lights
Specially Designed, Pliable “Foam-in-Place” Cabinet Seals
Available with Electronic Motor Circuit Protector (MCP) Circuit Breakers or
Fusible/Non-Fusible Disconnect Switch
NEMA Type 1, 12/3R Enclosure
HOA Selector Switch
Up to Two Normally Open (NO) and Two Normally Closed (NC) Auxiliary
Contacts
120 V Separate Control Voltage
Separate Control Voltage Interlock
Circuit Breaker
Combination Starter
MCP Circuit Breaker Combination Starters*
Mfr.’s
Type
NEMA
Size
Breaker
Size
Voltage
VAC
Horsepower
HP
Overload
Relay
70281247
8539SCASP6
1
30 A
240 or 480
Motor Logic
70281248
8539SDASP5
2
30 A
240 or 480
70281249
8539SDASP6
2
50 A
240 or 480
0.75 to 2.0 (240)
1.50 to 5.0 (480)
3.00 to 7.5 (240)
7.50 to 15.0 (480)
5.00 to 10.0 (240)
15.00 to 25.0 (480)
Current
Range
EACH
3-9 FLA
5358.13
Motor Logic
9-27 FLA
7212.37
Motor Logic
15-45 FLA
7212.37
ENCLOSURES
Stock
No.
*Horsepower rating also available at 208 and 600 VAC.
Disconnect Switch Combination Starters
Mfr.’s
Type
NEMA
Size
Fuse Clip
Size
Voltage
VAC
Horsepower
HP
Overload
Relay
Current
Range
EACH
70281261
70281262
70281263
70281264
8538SCASP4
8538SCASP5
8538SCASP6
8538SDASP4
0 or 1
1
0 or 1
1 or 2
30 A
60 A
30 A
60 A
208 or 240
208 or 240
480 or 600
208 or 240
Motor Logic
Motor Logic
Motor Logic
Motor Logic
3-9 FLA
9-27 FLA
6-18 FLA
15-45 FLA
3812.91
3841.10
3841.10
4808.94
70281265
70281266
8538SDASP5
8538SDASP6
1 or 2
2
30 A
60 A
480 or 600
480 or 600
0.75 to 2.0
3.00 to 7.5
5.00 to 10.0
5.00 to 10.0 (208)
5.00 to 15.0 (240)
7.50 to 10.0
15.00 to 25.0
Motor Logic
Motor Logic
9-27 FLA
15-45 FLA
4808.94
4852.78
INTERCONNECT
NEMA Style Contactors
Disconnect Switch
Combination Starter
POWER
Stock
No.
NEMA Style Motor Starters with Solid
State Overload Relays
TEST & MEASUREMENTS
8502SAO12V01S
8702SCO8V01S
Type S Contactors:
Class 8502 Type S magnetic contactors are used to switch heating loads, capacitors, transformers,and electric motors where
overload protection is separately provided. Class 8502 contactors are available in NEMA sizes 00-7. Type S contactors are
designed for operation at 600 VAC, 50-60 Hertz.
Full Voltage Non-Reversing Contactors
Mfr.’s
Type
Ampere
Rating
Coil
Voltage
70060142
70060143
70060144
70060145
70060146
70060147
8502SAO12V01S
8502SAO12V02S
8502SBO2V01S
8502SBO2V02S
8502SCO2V01S
8502SCO2V02S
9
9
18
18
27
27
24 VAC
120 VAC
24 VAC
120 VAC
24 VAC
120 VAC
Enclosure
Type
NEMA
Size
Horsepower Rating
@ 230 VAC @ 480 VAC
EACH
00
00
0
0
1
1
1.5
1.5
3.0
3.0
7.5
7.5
2
2
5
5
10
10
274.34
274.34
345.21
345.21
404.41
404.41
NEMA 1
Open
Open
NEMA 1
NEMA 1
Open
Open
NEMA 1
NEMA 1
Open
Open
00
00
00
0
0
0
0
1
1
1
1
1.5
1.5
1.5
3.0
3.0
3.0
3.0
7.5
7.5
7.5
7.5
2
2
2
5
5
5
5
10
10
10
10
764.62
682.85
712.92
907.23
907.18
855.49
855.49
1005.51
1049.77
974.74
974.74
Full Voltage Reversing Contactors
70060160
70060161
70060162
70060163
70060164
70060165
70060166
70060167
70060168
70060169
70060170
8702SAG4V02S
8702SAO4V01S
8702SAO4V02S
8702SBG4V01S
8702SBG4V02S
8702SBO4V01S
8702SBO4V02S
8702SCG8V01S
8702SCG8V02S
8702SCO8V01S
8702SCO8V02S
9
9
9
18
18
18
18
27
27
27
27
120 VAC
24 VAC
120 VAC
24 VAC
120 VAC
24 VAC
120 VAC
24 VAC
120 VAC
24 VAC
120 VAC
The proven workhorse of the Square D® motor control family, the Type S NEMA style starter has proven itself in a wide variety
of rugged applications over the last 40 years. The Type S starter offers a bell crank armature that limits contact bounce and
provides long contact life. Another unique feature that contributes to its long life are encapsulated coils that are designed to
work in harsh industrial environments. The Type S starter includes all of the serviceable features that you would expect from
a leader in NEMA style contactors, starters, combination starters and lighting contactors. The Type S starter has also been
enhanced over the years to take advantage of new technologies, most significantly with the introduction of our Motor Logic®
solid state overload relays in NEMA sizes 00-7. Motor Logic® solid state overload relays provide a wide thermal adjustment
range, minimal heat generation and the option to communicate with today’s automation systems.
Type S Starters:
Class 8536 Type S magnetic starters are used for full voltage starting and stopping AC squirrel cage motors. Solid state
overload relays provide motor overload protection. Class 8536 starters are available in NEMA Sizes 00-7. Type S starters are
designed for operation at 600 VAC, 50-60 Hz.
Features:
Solid State Overload Protection Allows User
to Adjust the Level of Protection
Selectable Automatic or Manual Reset
Overload Relay Does Not Require Separate
Heaters for Operation
Normally Open Holding Circuit Standard
on All Contactors
Bell Crank Actuation Ensures Contact Closure
Specifications:
Control Source Separate Control Circuit
Approvals UL Listed File E78351 CCN NLDX —
CSA Certified File LR60905 Class 3211 04
Enclosure Type: Open
Maximum Voltage Rating: 600 VAC
Overload Type Motor Logic (Class 20)
Phase: 3-Phase
Full Voltage Non-Reversing Starters
Horsepower Rating
NEMA
Size @ 230 VAC @ 480 VAC
Stock
No.
Mfr.’s
Type
Ampere
Rating
Coil
Voltage
Enclosure
Type
70282003
70282008
70282009
70282010
70282004
70282005
70282006
70282007
70282011
8536SAO12V02H30S
8536SAG12V01H30S
8536SAG12V02H30S
8536SBG2V02H30S
8536SBO2V01H30S
8536SBO2V02H30S
8536SCO3V01H30S
8536SCO3V02H30S
8536SCG3V02H30S
9
9
9
18
18
18
27
27
27
120 VAC
—
120 VAC
120 VAC
24 VAC
120 VAC
24 VAC
120 VAC
120 VAC
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
1.5
1.5
1.5
3.0
3.0
3.0
7.5
7.5
7.5
—
—
—
—
—
—
—
—
—
498.03
534.56
534.56
637.93
601.39
601.39
676.53
676.53
713.10
120 VAC
120 VAC
120 VAC
NEMA 1
Open
Open
00
00
0
1.5
1.5
3.0
2
2
5
901.66
847.51
990.00
EACH
INDEX
Open
Open
Open
Open
Open
Open
8736SAO16V02H30S
ASSEMBLY
Stock
No.
8536SBG2V02H30S
OPTOELECTRONICS
Specifications:
Control Source Separate Control Circuit
Approvals UL Listed File E78351 CCN NLDX —
CSA Certified File LR60905 Class 3211 04
Enclosure Type: Open
Maximum Voltage Rating: 600 VAC
Mounting Type: Surface
Phase 3-Phase
Features:
Normally Open Holding Circuit Standard on All
Contactors
Bell Crank Actuation Ensures Contact Closure
Wired for Separate Control
Normally Open Holding Circuit Contact for Three Wire
Control Is Provided as Standard
Sizes 00-2 Contactors Use a Class 9999 SX11
Auxiliary Contact as the Holding Circuit Contact
Sizes 3-7 Contactors Use a Class 9999 SX6 Auxiliary
Contact as the Holding Circuit Contact
Size 00-1 Single-Phase Contactors, a Power Pole Is
Used as the Holding Circuit Contact and Has the
Same Rating as the Power Contacts
8536SAO12V01H30S
PASSIVE & ACTIVE
AC MAGNETIC REVERSING CONTACTORS CLASS 8702:
General Information Class 8702 Type S reversing magnetic contactors are used for starting, stopping, and reversing AC
motors where overload protection is separately provided. Class 8702 reversing contactors are available in NEMA sizes 00-7.
Class 8702 reversing contactors consist of two Class 8502 contactors mechanically and electrically interlocked. Open type
devices, sizes 0-5 are available in either horizontal or vertical arrangements. Sizes 00, 6, and 7 are available as horizontal only.
Enclosed devices, size 00-7 use horizontally arranged components. Type S reversing contactors are designed for operation
at 600 VAC, 50-60 Hertz.
Full Voltage Reversing Starters
70378309 8736SAG16V02H30S
70378390 8736SAO16V02H30S
70378391 8736SBO4V02H30S
9
9
18
MOTOR CONTROLS, DRIVES & CONTACTORS 371
4
Download