FIRECOM ™ Technology Protecting Life® RA­41 Remote Annunciator RA­41P RA­41 Features Description u u u u u u u u u u u u u The RA­41/41P Remote Annunciator provides system status information in the LSN 2000 system. The RA­ 41/41P is a node on the network and can be config­ ured to monitor and annunciate either a portion or the entire system. System status changes are annunci­ ated by means of the 80 character (2x40 line) alphanu­ meric fluorescent display and an audible electronic piezo device. The RA­41/41P provides LEDs for Alarm, Trouble and Supervisory device status. The push button switches SYSTEM RESET, ALARM SILENCE, ACK/NEXT and PREV allow for resetting , silencing and acknowledg­ ing system events. As events are scrolled off the dis­ play the PREV switch can be used to recall those events. A Enable/Disable key switch is also provided to en­ able & disable the push button switches. Microprocessor Controlled 40,000 Point Capacity Alarm, Trouble & Supervisory LEDs Remote System Reset Switch Remote Alarm Silence Switch Remote Acknowledge Switch Enable/Disable Key Switch Displays Last 5 Events Echelon ® LonTalk ® Communications Wide Viewing Angle Blue Fluorescent Display 80 Characters Low Power Consumption RA­41 occupies 1/2 Module Footprint Installation Approvals and Listings Underwriters Laboratories (File No. S2184) NYC MEA (MEA No. 32­95­E) MEA CITY OF NEW YORK FIRECOM ™ , INC. 39­27 59th Street Woodside, NY 11377 718.899.6100 TEL 718.899.1932 FAX F I R E C O M I N C . C O M 71921 Rev 051201 1 of 2 Engineering Specifications The RA­41/41P Remote Annunciator shall provide status information on either a portion or the entire system. The Remote Annunciator shall contain a 80 character (2x40 line) alphanumeric fluorescent display with options to connect a remote printer. The RA­41/41P shall also provide system status LEDs for Alarm, Troubles and Supervisory devices within the system. Push button switches shall provide remote functions for System Reset, Alarm Silence and Acknowledge. All push button switches shall be capable of being disabled via a Enable/Disable key switch. The RA­41/41P shall mount to a backbox or with a Fire Command Center enclosure. Wiring Connection SERIAL 1 NO CONNECTION FX­890 PRINTER OFF ON 7 NETWORK CONN N ET A D ATA LIN ES TO NEXT PANEL 23 25 CN5 TB3 1 TX+ 2 TX­ Tx(­) Tx(+) 1 7 26 25 2 1 CN1 SW1 NET B DATA LINES TO NEXT PANEL JP3 TB1 Tx(­) Tx(+) 1 2 1 +24V 2 GND 3 A+ 4 A­ 5 B+ 6 B­ 7 EGND 8 EGND EARTH GND JP1 RESET SW2 SW3 SERVICE NET NET FIRECOM, INC. REMOTE ANNUNCIATOR BOARD RA­41 TB2 D600368B KEY SWITCH JP2 LOW BAT 1 AC FAIL 2 NO CONNECTION C 3 MAN 4 TRIP NO TP1 TB4 GND 1 2 NET A DATA LINES FROM PR EVIOUS PANEL NET B DATA LINES FR OM PR EVIOUS PAN EL 3 1 FIRECOM, INC. POWER SUPPLY PS­6A OUTPUT 5VDC @ 1A + ­ 2 4 KEY SWITCH TB3 1 24VDC @ 2.5A 2 24VDC @ 6A 3 TB4 DC COMMON 1 DC COMMON 2 TB5 AC­FAIL 1 LOW BAT 2 Electrical Specifications Operating Voltage Operating Current Operating Temperature Operating Relative Humidity Range 24VDC 140mA 0°C to 49°C 0% to 93% @ 32° C Ordering Information Model No. RA­41 RA­41P Part No. 72157 72177 Description Remote Annunciator Remote Annunciator Panel Mount It is our intention to keep the product information up to date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information contact: FIRECOM, INC. FIRECOM ™ , INC. 39­27 59th Street Woodside, NY 11377 718.899.6100 TEL 718.899.1932 FAX F I R E C O M I N C . C O M 71921 Rev 051201 2 of 2