trilux indoor

advertisement
Series 362···T···
Universal recessed and surface-mounted luminaires with translucent side sections
and highly-specular ultra-low cross-section louvre UXP-H or semi-specular ultra-low cross-section louvre UXP-S
6 5 4 d a
IP20
0.2 Joule
3622 T UXP-H···
Recommended applications
For more lighting comfort in offices, financial
institutions, sales areas, showrooms and
conference rooms. Universal application as
surface-mounted and recessed luminaires in
ceilings with cut-out recess openings as well
as in ceilings with concealed or exposed grids,
625 and 600 mm modules.
Optical system T UXP-H···
Secondary diffuser optics for increased lighting comfort, with convex, translucent PMMA
or PC covers, combined with semi-specular,
ultra-low cross-section louvre in UXP-Technology®, reflectance value 98 %. Suitable for
VDU applications in accordance with EN 12464-1
due to low luminance L ≤ 1000 cd/m2 at critical
angles above 65° in all planes.
UXP-H··· Highly-specular, scattering part ≤ 3 %
UXP-S··· Semi-specular.
Luminaire body
Sheet steel, white, recess depth max. 23 mm.
Underside: with front-plane plastic end caps,
silver-grey, inclined by 30° and perfectly
adapted to the luminaire profile.
···PC For increased preventive fire protection
with end caps and covers made of polycarbonate.
Control gear option
Versions ···/28/54··· and ···35/49··· in MultiLamp technology allow operation of T5 lamps
with different wattages.
···E··· With electronic control gear.
···EDD··· With digitally dimmable electronic
control gear (DALI).
Other electrical versions available on request.
650 °C
···PC··· 850 °C
3623 T UXP-H···
C0 - C180
3622 T UXP-H/49 E
UTE: 0.67 C + 0.02 T
DIN 5040: A50
CIBSE: BZ 1/2.5/BZ 2
NBN L 14-002:
BZ 2/4/BZ 3
C0 - C180
3623 T UXP-H/24 E
UTE: 0.64 C + 0.01 T
DIN 5040: A50
CIBSE: BZ 1/.75/BZ 2
NBN L 14-002: BZ 3
Accessories ······························288
Lamp characteristics ···············525
3622 T UXP-S···
Lamps
Axis dimension
D
D1
E1
E2
≈kg
51 734···
51 738···
45 679···
51 735···
51 736···
47 200···
Control gear
option
···E
···EDD
···04
···07
···04
···07
···04
···04
···07
···04
···07
···04
W
2 x 28/54
2 x 35/49
2 x 80
2 x 28/54
2 x 35/49
2 x 80
mm
300/312.5
300/312.5
300/312.5
300/312.5
300/312.5
300/312.5
1098
1398
1398
1098
1398
1398
74.5
74.5
74.5
74.5
74.5
74.5
–
–
–
–
–
–
30
30
30
30
30
30
6.4
7.7
7.7
6.4
7.7
7.7
3623 T UXP-H/24···
3623 T UXP-H/24 PC···
45 680···
47 206···
···04
···04
3 x 24
3 x 24
600/625
600/625
523
523
50
50
231.5
231.5
32
32
5.3
5.3
···UXP-S···
3622 T UXP-S/28/54···
3622 T UXP-S/35/49··
3622 T UXP-S/80···
3622 T UXP-S/28/54 PC···
3622 T UXP-S/35/49 PC···
3622 T UXP-S/80 PC···
49 758···
48 614··
47 212···
51 739···
51 740···
47 205···
···04
···04
···04
···04
···04
···04
2 x 28/54
2 x 35/49
2 x 80
2 x 28/54
2 x 35/49
2 x 80
300/312.5
300/312.5
300/312.5
300/312.5
300/312.5
300/312.5
1098
1398
1398
1098
1398
1398
74.5
74.5
74.5
74.5
74.5
74.5
–
–
–
–
–
–
30
30
30
30
30
30
6.4
7.7
7.7
6.4
7.7
7.7
3623 T UXP-S/24···
3623 T UXP-S/24 PC···
47 213···
47 207···
···04
···04
3 x 24
3 x 24
600/625
600/625
523
523
50
50
231.5
231.5
32
32
5.3
5.3
···07
···07
···07
···07
3622 T UXP···
3623 T UXP···
D
D
D1
E
E2
D1
310
···UXP-H···
3622 T UXP-H/28/54···
3622 T UXP-H/35/49··
3622 T UXP-H/80···
3622 T UXP-H/28/54 PC···
3622 T UXP-H/35/49 PC···
3622 T UXP-H/80 PC···
274
TOC
E2
E
18
Reference
3623 T UXP-S···
1175/28W/54W
1475/35W/49W/80W
1247/28W/54W
1547/35W/49W/80W
E1
575
Series 362···
Universal recessed and surface-mounted luminaires with highly-specular parabolic louvre
semi-specular RSX or highly-specular RPX
6 5 4 d a
IP20
0.2 Joule
650 °C
···PC··· 850 °C
3621 RSX···
Recommended areas
For efficient and elegant lighting of offices,
sales areas, showrooms and financial institutions, especially suited to VDU workstations.
TC-SEL 11W versions particularly recommended for corridors and entrance areas.
Universal application as surface-mounted and
recessed luminaires in ceilings with cut-out
recess openings as well as in ceilings with
concealed or exposed grids, 625 and 600 mm
modules.
Optical system
Micro-segmented parabolic louvre made of
made of reflection-intensifying aluminium with
a surface purity of 99.99 %. Suitable for VDU
applications in accordance with EN 12464-1 due
to low luminance L ≤ 1000 cd/m2 at critical
angles above 65° in all planes. Louvre retention by means of spring-tensioned clips, providing earth continuity. Louvre can be lowered
and hung from either side without tools.
···RSX··· Semi-specular.
···RPX··· Highly-specular.
3622 RSX···
C0 - C180
Luminaire body
Sheet steel, white, glossy finish, refined to a
particularly elegant convex design, oriented
towards room. With flush end caps, inclined
by 30° and perfectly adapted to the rounded
profile of the luminaire body. Necessary recess
depth is only 18 mm.
···PC with end caps made of polycarbonate.
For increased preventive fire protection.
3621 RSX/35 E
UTE: 0.83 B
DIN 5040: A60
CIBSE: BZ 2/1.5/BZ 1
NBN L 14-002:
BZ 2/.8/BZ 1
Control gear option
Versions ···28/54··· and ···35/49/80··· in MultiLamp technology allow operation of T5 lamps
with different wattages.
···E With electronic control gear.
···EDD With digitally dimmable electronic control gear (DALI).
C0 - C180
3622 RSX/TC11
UTE: 0.55 B
DIN 5040: A60
CIBSE: BZ 1
NBN L 14-002: BZ 1
Other electrical versions available on request.
C0 - C180
3623 RSX/14 E
UTE: 0.83 B
DIN 5040: A50
CIBSE: BZ 2/3/BZ 1/
4/BZ 2
NBN L 14-002:
BZ 2/1/BZ 1
3621···
3622···
28/54W
35/49/80W
28/54W
35/49W
28/54W
35/49/80W
28/54W
35/49W
Accessories ······························288
Lamp characteristics ···············525
3622 RPX/TC11···
3623 RPX···
43 359···
32 586···
57 901···
57 902···
Control gear
option
···E
···EDD
···04
···07
···04
···07
···04
···07
···04
···07
3622 RSX/28/54···
3622 RSX/35/49···
3622 RSX/28/54 PC···
3622 RSX/35/49 PC···
57 912···
57 914···
57 913···
57 915···
···04
···04
···04
···04
3623 RSX/14···
3623 RSX/14 PC···
3622 RSX/TC11···
3622 RSX/TC11 PC···
···RPX···
3621 RPX/28/54···
3621 RPX/35/49/80···
3621 RPX/28/54 PC···
3621 RPX/35/49/80 PC···
11 351···
14 887···
11 345···
14 882···
···04
···04
···04
···04
32 561···
32 566···
57 899···
57 900···
···04
···04
···04
···04
3622 RPX/28/54···
3622 RPX/35/49···
3622 RPX/28/54 PC···
3622 RPX/35/49 PC···
57 908···
57 910···
57 909···
57 911···
···04
···04
···04
···04
3623 RPX/14···
3623 RPX/14 PC···
3622 RPX/TC11···
3622 RPX/TC11 PC···
11 349···
14 885···
11 339···
14 879···
···04
···04
···04
···04
Reference
TOC
···RSX···
3621 RSX/28/54···
3621 RSX/35/49/80···
3621 RSX/28/54 PC···
3621 RSX/35/49/80 PC···
D
D1
W
1 x 28/54
1 x 35/49/80
1 x 28/54
1 x 35/49/80
Axis
dimension
mm
300/312.5
300/312.5
300/312.5
300/312.5
mm
900
1200
900
1200
2 x 28/54
2 x 35/49
2 x 28/54
2 x 35/49
300/312.5
300/312.5
300/312.5
300/312.5
3 x 14
3 x 14
2 x TC-SEL 11
2 x TC-SEL 11
···07
···07
···07
···07
···07
···07
···07
···07
···07
···07
···07
···07
Lamps
E1
≈kg
174
174
174
174
56
56
56
56
5.0
6.2
5.0
6.2
900
1200
900
1200
174
174
174
174
96
96
96
96
5.3
6.6
5.3
6.6
600/625
600/625
300/312.5
300/312.5
480
480
150
150
72
72
111
111
137
137
96
96
4.3
4.3
1.6
1.6
1 x 28/54
1 x 35/49/80
1 x 28/54
1 x 35/49/80
300/312.5
300/312.5
300/312.5
300/312.5
900
1200
900
1200
174
174
174
174
56
56
56
56
4.4
5.5
4.4
5.5
2 x 28/54
2 x 35/49
2 x 28/54
2 x 35/49
300/312.5
300/312.5
300/312.5
300/312.5
900
1200
900
1200
174
174
174
174
96
96
96
96
4.4
5.5
4.4
5.5
3 x 14
3 x 14
2 x TC-SEL 11
2 x TC-SEL 11
600/625
600/625
300/312.5
300/312.5
480
480
150
150
72
72
111
111
137
137
96
96
4.3
4.3
1.6
1.6
3622···/TC11···
3623···/14···
D2
220
220
220
220
Series 362···
Universal surface-mounted and recessed luminaires with white louvre RWV
or semi-specular parabolic louvre RMV
6 5 4 d a
IP20
0.2 Joule
650 °C
···RWV···PC··· 850 °C
···RMV···
3621 RWV···
Recommended areas
For efficient and elegant lighting of offices,
sales areas, showrooms and financial institutions.
···RWV··· Especially suited to VDU workstations.
TC-SEL 11W versions particularly recommended for corridors and entrance areas.
Universal application as surface-mounted and
recessed luminaires in ceilings with cut-out
recess openings as well as in ceilings with
concealed or exposed grids, 625 and 600 mm
modules.
Optical system
···RWV··· Micro-segmented louvre made of
aluminium, white, for a uniform light distribution.
···RMV··· Micro-segmented parabolic louvre
made of semi-specular anodised aluminium
with a surface purity of 99.98 %. Suitable for
VDU applications in accordance with EN
12464-1 due to low luminance L ≤ 1000 cd/m2
at critical angles above 65° in all planes.
3622 RWV···
C0 - C180
Luminaire body
Sheet steel, white, glossy finish, refined to a
particularly elegant convex design, oriented
towards room. With flush end caps, inclined
by 30° and perfectly adapted to the rounded
profile of the luminaire body. Necessary recess
depth is only 18mm.
···RWV···PC with end caps made of polycarbonate. For increased demands on preventive
fire protection.
3621 RWV/35 E
UTE: 0.80 C
DIN 5040: A50
CIBSE: BZ 1
NBN L 14-002: BZ 2
C0 - C180
Control gear options
Versions ···28/54··· and ···35/49/80··· in MultiLamp technology allow operation of T5 lamps
with different wattages.
···E With electronic control gear.
···EDD With digitally dimmable electronic control gear (DALI).
3621 RMV/35 E
UTE: 0.68 C
DIN 5040: A50
CIBSE: BZ 3/.75/BZ 2
NBN L 14-002: BZ 2
Other electrical versions available on request.
C0 - C180
3622 RMV/TC11
UTE: 0.48 B
DIN 5040: A60
CIBSE: BZ 1
NBN L 14-002:
BZ 2/.8/BZ 1
Louvre retention by means of spring-tensioned
clips, providing earth continuity. Louvre can be
lowered and hung from either side without
tools.
3621···
3622···
28/54W
35/49/80W
28/54W
35/49W
28/54W
35/49/80W
28/54W
35/49W
Accessories ······························288
Lamp characteristics ···············525
3622 RMV/TC11···
Reference
TOC
···RWV···
3621 RWV/28/54···
3621 RWV/35/49/80···
3621 RWV/28/54 PC···
3621 RWV/35/49/80 PC···
3623 RMV···
57 903···
40 649···
57 904···
57 905···
Control gear
option
···E
···EDD
···04
···07
···04
···07
···04
···07
···04
···07
3622 RWV/28/54···
3622 RWV/35/49···
3622 RWV/28/54 PC···
3622 RWV/35/49 PC···
57 916···
57 918···
57 917···
57 919···
···04
···04
···04
···04
D
D1
W
1 x 28/54
1 x 35/49/80
1 x 28/54
1 x 35/49/80
Axis
dimension
mm
300/312.5
300/312.5
300/312.5
300/312.5
900
1200
900
1200
2 x 28/54
2 x 35/49
2 x 28/54
2 x 35/49
300/312.5
300/312.5
300/312.5
300/312.5
3622 RWV/TC11···
3622 RWV/TC11 PC···
58 117···
58 116···
···04
···04
2 x TC-SEL 11
2 x TC-SEL 11
···RMV···
3621 RMV/28/54···
3621 RMV/35/49/80···
57 897···
57 898···
···04
···04
···07
···07
3622 RMV/28/54···
3622 RMV/35/49···
57 906···
57 907···
···04
···04
···07
···07
3623 RMV/14···
3622 RMV/TC11···
47 660···
47 659···
···04
···04
···07
···07
···07
···07
Lamps
E1
≈kg
174
174
174
174
56
56
56
56
4.4
5.5
4.4
5.5
900
1200
900
1200
174
174
174
174
96
96
96
96
4.4
5.5
4.4
5.5
300/312.5
300/312.5
150
150
111
111
96
96
1.6
1.6
1 x 28/54
1 x 35/49/80
300/312.5
300/312.5
900
1200
174
174
56
56
4.4
5.5
2 x 28/54
2 x 35/49
300/312.5
300/312.5
900
1200
174
174
96
96
4.4
5.5
3 x 14
2 x TC-SEL 11
600/625
300/312.5
480
150
72
111
137
96
4.3
1.6
3622···/TC11···
3623···/14···
D2
220
Series 362···
Information and accessories for luminaire installation
Semi-recessed or surface-mounted
Luminaires of the series 362··· are credible as semi-recessed and
surface-mounted luminaires. Their convex profile with the contoured
side sections of the luminaire body allows the luminaires to blend
harmoniously into the surrounding ceiling areas.
In the case of surface-mounted version, the surrounding shadow gap
provides an interesting appearance.
The adjacent illustrations show examples of commonly used grid
and ceiling systems and the flange widths permissible for luminaire
mounting. The maximum total height for grids plus ceiling tile is a
uniform 56 mm for all types of ceilings.
Ceilings with exposed grids
Maximum height of the grid is 56 mm.
Maximum lower flange width is 24 mm.
max. 56 mm
max. 24 mm
Ceilings with concealed grids
Maximum height of the grid plus ceiling tile is 56 mm.
Maximum lower flange width is 24 mm.
max. 56 mm
max. 24 mm
Ceilings with cut-out recess openings
Maximum height of the grid plus ceiling tile is 56 mm.
Maximum grid overhang is 12 mm.
max. 56 mm
max. 12 mm
By means of the fixing accessories 03620··· described on the right,
362··· luminaires can easily be mounted in all conventional ceiling
types:
1. Ceiling systems with concealed grids.
2. Ceiling systems with exposed grids.
3. Ceilings with cut-out recess openings, e.g., made of wood
or gypsum plaster.
Fixing accessories
1 set of mounting rails for the mounting of luminaires in ceiling
systems or in ceilings with cut-out recess openings.
03620/1
For luminaires 3621···, 3622···.
03620/3
For luminaires 3623···.
21 484 00
21 485 00
Installation suggestions for module ceilings
Installation suggestions for module ceilings
Luminaires
Luminaires
3621···
3622···
3622···
Module 600 mm
Module 600 mm
Module 625 mm
Module 625 mm
Module 600 mm
Module 600 mm
Module 625 mm
Module 625 mm
Cut-out openings
... for 3622···/TC11···
... for 3621···, 3622···
... for 3621···, 3622···
334 x 290 mm
1210 x 290 mm
1510 x 290 mm
Cut-out openings
... for 3623 RPX/14···
... for 3623···/14···
... for 3623···/24···
600 x 600 mm
600 x 600 mm
600 x 600 mm
TRILUX säljs i Sverige genom:
PROLJUS AB
Kyrkogatan 18
570 03 VRIGSTAD
www.proljus.se
info@proljus.se
Björn Celén
bjorn.celen@proljus.se
070-601 05 63
Johan Celén
johan.celen@proljus.se
070-382 29 63
Download