GENERAL NOTES
POLE LIGHT ASSEMBLY "PL1" SHALL BE SINGLE HEAD 350 WATT PULSE
START METAL HALIDE SHOEBOX TYPE POLE LIGHT ASSEMBLY, TYPE IV
DISTRIBUTION, MOUNTED ON A 25' STRAIGHT SQUARE STEEL POLE. PROVIDE
HOUSE SIDE SHIELDS ALONG PROPERTY LINES AND MUNICIPAL ROADWAYS.
COLOR SELECTION BY ARCHITECT. MANUFACTURER SHALL BE EQUAL TO
WIDELITE.
HP1:31,33
PL1
B.
C.
D.
POLE LIGHT ASSEMBLY "PL2" SHALL BE TWIN HEAD 350 WATT PULSE START
METAL HALIDE SHOEBOX TYPE POLE LIGHT ASSEMBLY, TYPE III DISTRIBUTION,
MOUNTED ON A 25' STRAIGHT SQUARE STEEL POLE. COLOR SELECTION BY
ARCHITECT. MANUFACTURER SHALL BE EQUAL TO WIDELITE.
HP1:27,29
PL2
ALL WORK SHALL BE IN COMPLIANCE WITH THE MOST CURRENT
EDITION OF THE NATIONAL ELECTRICAL CODE, STATE CODE(S) AND
LOCAL CODE(S).
ELECTRICAL CONTRACTOR SHALL VISIT THE SITE TO FAMILIARIZE
THEMSELVES WITH THE SCOPE OF THE PROJECT PRIOR TO BID.
REFER TO ARCHITECTURAL DRAWINGS FOR WALL AND CEILING
CONSTRUCTION TYPES.
ELECTRICAL DRAWINGS SHOULD NOT BE SCALED, REFER TO
ARCHITECTURAL DRAWINGS AND ADDITIONAL DETAILS CONTAINED HEREIN
FOR DIMENSIONING AND SCALING.
FOR THE (2) POLE LIGHT ASSEMBLIES AT THE BASKETBALL COURT, PROVIDE
TRIPLE BULLHORN POST-TOP BRACKET WITH (3) TYPE "SL1" 350 WATT
PULSE START METAL HALIDE SPORTSLIGHTERS, CONTROLLED BEAM. CIRCUIT
SPORTSLIGHTERS TO PANEL "MB1". MANUFACTURER SHALL BE EQUAL TO
WIDELITE.
HP1:31,33
PL1
HP2:19,21
PL1
HP1:27,29
PL2
HP2:19,21 7 TYP
PL1
HP2:19,21
PL1
HP1:31,33
PL1
HP1:23,25
PL2
HP1:31,33
HP1:27,29
PL2
3
HP1:31,33
PL1
3
1
PROPOSED LOCATION OF UTILITY COMPANY TRANSFORMER. EXACT LOCATION MUST BE
COORDINATED WITH LOCAL UTILITY COMPANY PRIOR TO INSTALLATION. CONCRETE
TRANSFORMER PAD BY ELECTRICAL CONTRACTOR.
2
PROVIDE (1) 5" CONDUIT TO UTILITY EASEMENT FOR PRIMARY CABLING. PROVIDE
1/4" NYLON PULL ROPE IN CONDUIT. PROVIDE WARNING RIBBON 12" ABOVE TOP OF
BURIED CONDUIT. COORDINATE CONDUIT ROUTING WITH LOCAL UTILITY COMPANY.
3
PROVIDE (3) 4" CONDUITS TO UTILITY EASEMENT FOR TELEPHONE AND CABLE
TELEVISION CABLING. ROUTE CONDUIT TO IN-GROUND PULL BOX AS SHOWN,
24"X36"X24". PROVIDE 1/4" NYLON PULL ROPE IN EACH CONDUIT. PROVIDE WARNING
RIBBON 12" ABOVE TOP OF BURIED CONDUIT. COORDINATE CONDUIT ROUTING WITH
LOCAL UTILITY COMPANIES. PROVIDE (2) 4" CONDUITS FROM PULL BOX TO EACH IDF
ROOM AS SHOWN (PROVIDE ADDITIONAL PULL BOXES AS SHOWN).
4
PROVIDE (1) 4" CONDUIT TO MAINTENANCE BUILDING FOR TELEPHONE CABLING.
PROVIDE 1/4" NYLON PULL ROPE IN CONDUIT. PROVIDE WARNING RIBBON 12" ABOVE
TOP OF BURIED CONDUIT. COORDINATE CONDUIT ROUTING WITH OTHER TRADES.
5
PROVIDE 24" DIAMETER CONCRETE POLE BASE FOR EACH PARKING LIGHT ASSEMBLY,
24" ABOVE GRADE, 72" BELOW GRADE, STEEL REINFORCED.
6
PROVIDE ELECTRICAL CIRCUIT AND IN-GROUND JUNCTION BOX FOR SIGNAGE
REQUIREMENTS.
7
ALL SITE LIGHTING AND SIGNAGE CIRCUITRY SHALL BE #8 CU (MINIMUM) FOR EACH
PHASE, GROUNDED (NEUTRAL), AND GROUNDING CONDUCTOR. CONDUIT SHALL BE 1"
MINIMUM.
8
SEE RISER DIAGRAMS ON SHEET E401 AND E402 FOR METERING CENTER INFORMATION,
SECONDARY SERVICE ENTRANCE SIZES, ETC.
9
LOCATION OF MAINTENANCE BUILDING, ELECTRICAL PANEL WITHIN MAINTENANCE BUILDING
SHALL BE FED FROM ELECTRICAL SERVICE #5.
10
LOCATION OF CLUBHOUSE METERING EQUIPMENT AND SERVICE DISCONNECT SWITCH.
CLUBHOUSE ELECTRICAL SERVICE SHALL BE 600 AMP, 120/240 VOLT SINGLE PHASE 3
WIRE. ELECTRICAL FEEDER TO DISCONNECT SWITCH SHALL BE (2) SETS OF (3) 500
MCM AL IN (2) 3" CONDUITS, ROUTED TO UTILITY TRANSFORMER AS SHOWN.
11
PROVIDE ELECTICAL FEEDER FROM DISCONNECT SWITCH TO CLUBHOUSE ELECTRICAL
PANEL CONSISTING OF (2) SETS OF (3) 500 MCM AL, (1) #2/0 AL GROUND IN (2)
3" CONDUITS. IN ADDITION, PROVIDE ELECTRICAL FEEDER FROM CLUBHOUSE
ELECTRICAL PANEL TO POOL EQUIPMENT ROOM ELECTRICAL PANEL CONSISTING OF (3) #
3/0 AL, (1) #4 AL GROUND IN 2" CONDUIT. SEE SHEET E116 FOR LOCATIONS OF
THESE ELECTRICAL PANELS.
12
LOCATION OF BASKETBALL SPORTSLIGHTING CONTROLS. PROVIDE NEMA 4X HINGED
COVER BOX WITH MOMENTARY CONTACT ON/OFF SELECTOR BUILT INTO THE COVER. IN
ADDITION, PROVIDE ELECTRICALLY HELD LIGHTING CONTACTOR AND 24 HOUR 7 DAY
TIMECLOCK MOUNTED INSIDE BOX. ROUTE LIGHTING CIRCUITS MB1:13 AND MB1:15
THRU LIGHTING CONTACTOR WITH THE CONTACTOR COIL ACTUATED AS A FUNCTION OF
THE TIMECLOCK AND SELECTOR SWITCH DURING THE DESIGNATED HOURS. CIRCUITS
SHALL BE MADE SELECTABLE STARTING AT DUSK AND SHALL BE TURNED OFF AT A TIME
AS DESIGNATED BY THE OWNER TO AVOID LIGHTING BEING LEFT ON ALL NIGHT. ONCE
LIGHTING CIRCUITRY IS TURNED OFF VIA TIMECLOCK, THE CONTACTOR COIL SHALL BE
RELEASED AND SHALL NOT BE ENERGIZED UNTIL DUSK THE FOLLOWING DAY.
13
PROVIDE ELECTRICAL CIRCUITS AND IN-GROUND JUNCTION BOXES FOR GATE MOTORS.
VERIFY EXACT POWER REQUIREMENTS WITH EQUIPMENT SUPPLIER.
3
2
PL1
PLAN NOTES
LOW VOLTAGE
PULL BOX
2
LOW VOLTAGE
PULL BOX
UTILITY XFMR
(PROPOSED 1
LOCATION)
HP2:19,21
PL1
2
IDF
PL1
ELEC SERVICE #3
ELEC SERVICE #4
HP1:23,25
ELEC SERVICE #1
MDF
IDF
(SECOND FLOOR)
STAIRS
3
ELEC SERVICE #2
1 UTILITY XFMR
(PROPOSED LOCATION)
HP2:19,21
PL1
5 TYP
PL1
HP1:23,25
J-BOX FOR GATE
HP2:27
13
HP2:29
J
J
UP
6
IDF
HP2:19,21
PL1
11
INFINITY
EDGE POOL
PL1
HP1:23,25
Nacogdoches, TX
A.
LUMBERJACK LOFTS
SFA 1411 ASSOCIATES, L.P.
PARKING LOT LIGHTING
J
J-BOX FOR SIGNAGE
HP2:23
11
Electrical Site
Plan
UP
HP3:21,23
PL1
J
J
PERMIT SET
LOW VOLTAGE
PULL BOX
10
J-BOX FOR GATE
HP3:39
13
HP3:41
PL1
HP3:29,31
IDF
IDF
1
HP3:21,23
PL1
ELEC SERVICE #5
UTILITY XFMR
(PROPOSED LOCATION)
LOW VOLTAGE
PULL BOX
TA
OF TE
TE
X
A
S
S
UP
2
TRENT E BEIGHLE
HP3:21,23
PL2
R
100821
PR
3
O
FE
PL1
HP3:29,31
UTILITY XFMR 1
(PROPOSED LOCATION)
EE
ELEC SERVICE #6
LIC
SS
E NS ED IN
G
IONA L EN
PE-SERVICES
F-10841
EXP: 11/30/12
PL1
HP3:21,23
2
HP3:29,31
PL2
4
HP3:29,31
PL2
HP3:21,23
PL1
LOW VOLTAGE
PULL BOX
PL1
HP3:29,31
ARCHITECTURE DEMAREST
C ARCHITECTURE DEMAREST, L.P.
ALL RIGHTS RESERVED
J
PL2
HP3:25,27
PL2
HP3:25,27
HP3:25,27
PL1
SL1
HP3:25,27
PL1
SL1
SL1
SL1 MB1:15
12
J-BOX FOR GATE
HP3:35
13
HP3:37
DATE
07/16/12
J
HP3:25,27
PL1
Revision Schedule
No. Date
Description
SL1
SL1 MB1:13
9
BASKETBALL COURT
LIGHTING CONTROL
JOB NO.
Electrical Site Plan
1
1" = 40'-0"
COPYRIGHT (C) 2011 ARCHITECTURE DEMAREST, L.P. ALL IDEAS, DESIGNS, ARRANGEMENTS, PLANS, AND SPECIFICATIONS INDICATED OR REPRESENTED BY THIS DRAWING AS INSTRUMENTS OF SERVICE ARE AND SHALL REMAIN THE EXCLUSIVE INTELLECTUAL PROPERTY OF ARCHITECTURE DEMAREST, L.P. AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THIS SPECIFIED PROJECT ONLY. NONE OF SUCH
IDEAS, DESIGN, ARRANGEMENTS OR PLANS SHALL BE USED ON ANY OTHER PROJECT OR EXTENSIONS OF THIS PROJECT OR USED BY OR DISCLOSED TO ANY PERSON, FIRM OR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION FORM AND APPROPRIATE COMPENSATION TO ARCHITECTUREDEMAREST, L.P. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. THE CONTRACTOR
SHALL BEAR SOLE RESPONSIBILITY FOR VERIFYING ALL DIMENSIONS ON THIS PROJECT AND NOTIFIYING ARCHITECTURE DEMAREST, L.P. OF ANY DEVIATIONS. THE CONTRACTOR SHALL BEAR SOLE RESPONSIBILITY FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, CONFIRMING COORDINATION AND FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT. ARCHITECTURE DEMAREST, L.P.
WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT.
10051
SHEET NO.
E110
BUILDING KEYPLAN
UP
AREA A3
A.
AREA A1
PLAN NOTES
GENERAL NOTES
UP
AREA A2
B.
UP
CLUBHOUSE
C.
UP
D.
AREA B1
E.
AREA B2
F.
UP
ALL WORK SHALL BE IN COMPLIANCE WITH THE MOST CURRENT
EDITION OF THE NATIONAL ELECTRICAL CODE, STATE CODE(S) AND
LOCAL CODE(S).
ELECTRICAL CONTRACTOR SHALL VISIT THE SITE TO FAMILIARIZE
THEMSELVES WITH THE SCOPE OF THE PROJECT PRIOR TO BID.
REFER TO ARCHITECTURAL DRAWINGS FOR WALL AND CEILING
CONSTRUCTION TYPES.
ELECTRICAL DRAWINGS SHOULD NOT BE SCALED, REFER TO
ARCHITECTURAL DRAWINGS AND ADDITIONAL DETAILS CONTAINED
HEREIN FOR DIMENSIONING AND SCALING.
ELECTRICAL WIRING, EQUIPMENT, APPARATUS, ETC. LOCATED ABOVE
CEILINGS SHALL BE LISTED FOR USE IN AIR HANDLING PLENUMS AND
SHALL BE INSTALLED IN ACCORDANCE WITH NEC 300.22. THIS
INCLUDES ALL LOW VOLTAGE CABLING AND EQUIPMENT.
LIGHT SWITCHES SHALL BE INSTALLED IN ACCESSIBLE LOCATIONS NO
HIGHER THAN 42" AFF. ALL SWITCHES IN APARTMENTS SHALL BE
ROCKER TYPE SWITCHES.
1
HEAT PUMP SERVING RESIDENCES. CIRCUITRY IS SHOWN ON THE TYPICAL RESIDENCE
PLANS. COORDINATE SPECIFIC UNIT WITH MECHANICAL DRAWINGS.
2
PROVIDE ELECTRICAL CONNECTION AND ELECTRICAL CIRCUITRY FOR ELECTRIC UNIT
HEATER. CIRCUITRY SHALL BE AS INDICATED IN THE ELECTRICAL PANEL SCHEDULES.
3
PROVIDE FIRE-RATED PLYWOOD EQUIPMENT BACKBOARD ON BACK AND SIDE WALL OF
ELECTRICAL CLOSET FOR THE MOUNTING OF TELEPHONE, DATA, TELEVISION, FIRE ALARM
AND ELECTRICAL DISTRIBUTION EQUIPMENT. PROVIDE (1) #3 COPPER GROUND WIRE FROM
MAIN GROUNDING ELECTRODE TO EQUIPMENT BACKBOARD. PROVIDE 12"X3"X1/4" COPPER
TERMINATION BAR FOR USE BY THE LOW VOLTAGE SYSTEMS INSTALLER(S).
4
PROVIDE ELECTRICAL CONNECTION AND ELECTRICAL CIRCUITRY FOR FIRE ALARM PANEL.
5
PROVIDE POWER DEVICES AND ELECTRICAL CIRCUITRY AS SHOWN FOR TELEPHONE, DATA,
TELEVISION AND FIRE ALARM EQUIPMENT REQUIREMENTS. VERIFY EXACT LOCATIONS PRIOR
TO ROUGH-IN.
6
PROVIDE ELECTRICAL CONNECTION AND ELECTRICAL CIRCUITRY FOR MINI-SPLIT DEDICATED
SYSTEM. SEE ELECTRICAL PANEL SCHEDULES FOR CIRCUITRY SIZES.
MANUFACTURER
CATALOG #
VOLT
LAMPING
MOUNTING
DESCRIPTION
B1
LIGHTOILER
SW8T232HPF-UNV-(2)NSYMF48S CSP
120
(4) F32T8
SURFACE
8' 4-LAMP (TANDEM) FLUORESCENT INDUSTRIAL LIGHT WITH APERATURED REFLECTOR, PROVIDE WITH CHAIN-HANGERS WHERE REQUIRED
B2
LIGHTOILER
SW4T232HPF-UNV-NSYMF48S CSP
120
(2) F32T8
SURFACE
4' 2-LAMP FLUORESCENT INDUSTRIAL LIGHT WITH APERATURED REFLECTOR, PROVIDE WITH CHAIN-HANGERS WHERE REQUIRED
EM1
BEST LIGHTING
R1
120
INCLUDED
SURFACE
TWO HEAD EMERGENCY EGRESS LIGHT FIXTURE - BATTERY BACK-UP
S1
DESIGN PARTNERS INTL
EB962-32
120
(1) 32W CFL
SURFACE
SURFACE MOUNT CORRIDOR LIGHTING
S2
DESIGN PARTNERS INTL
555-232
120
(2) F32T8
SURFACE
STAIRWELL LIGHT FIXTURE
V
LIGHTOILER
ST4WA232-120-SO
120
(2) F32T8
SURFACE
4' 2-LAMP FLUORESCENT VAPORTITE LIGHT WITH 100% HIGH IMPACT DR ACRYLIC LENS
WP1
DESIGN PARTNERS INTL
MWPB3ACO
120
175W MH
WALL
METAL HALIDE EXTERIOR WALL PACK LIGHT FIXTURE
X1
LITHONIA
LHQM S W 3 R N
120
INCLUDED
WALL/CEILING
EMERGENCY/EXIT COMBO LIGHT FIXTURE, BATTERY BACK-UP
NOTES:
1. CONTRACTOR MUST PROVIDE UNIT PRICING AND FIXTURE SUBMITTALS FOR OWNER APPROVAL.
2. THE OWNER AND LIGHTING DESIGNER MUST APPROVE FIXTURE SUBSTITUTIONS. CONTRACTOR MUST BE PREPARED TO SUPPLY A SAMPLE AND/OR PHOTOMETRIC DATA IF REQUESTED. IF THE SUBSTITUTION IS REJECTED, THE CONTRACTOR MUST BE PREPARED
TO SUPPLY A SAMPLE AND/OR PHOTOMETRIC DATA IF REQUESTED. IF THE SUBSTITUTION IS REJECTED, THE CONTRACTOR MUST BE PREPARED TO PROVIDE THE SPECIFIED PRODUCT WITHOUT DELAY
3. PROVIDE LAMPS AS SPECIFIED OR SUBMIT ALTERNATE MANUFACTURERS FOR APPROVAL. GENERAL ELECTRIC, PHILIPS AND OSRAM/SYLVANIA ONLY WILL BE CONSIDERED
4. ALL FIXTURES MUST BE UL LABELED FOR THE INTENDED LOCATION
5. ALL COLORS AND FINISH SELECTIONS SHALL BE DETERMINED BY ARCHITECT AND/OR OWNER'S REPRESENTATIVE
6. LAMP COLORS ASSOCIATED WITH LINEAR FLUORESCENT LIGHT FIXTURES SHALL BE DETERMINED BY ARCHITECT (UNLESS SPECIFICALLY NOTED OTHERWISE WITHIN THE LIGHT FIXTURE SCHEDULE)
2
E111
TYP
HP1:8
WP/GFI
HP1:8
WP/GFI
HP1:8
WP/GFI
HP1:8
WP/GFI
PERMIT SET
HP1:8
WP/GFI
Electrical Plan First Floor
Section A1
1
Nacogdoches, TX
TYPE
LUMBERJACK LOFTS
SFA 1411 ASSOCIATES, L.P.
POOL EQUIPMENT AND RESTROOM / CORRIDOR / MAINTENANCE BUILDING LIGHTING FIXTURE SCHEDULE
J
S1
HP1:1
S1
HP1:1
EM1
HP1:1
HP1:4
WP/GFI
S1
HP1:1
S1
HP1:1
F
S1
HP1:1
S1
HP1:1
EM1
HP1:1
S1
HP1:1
S1
HP1:1
HP1:4
WP/GFI
F
EM1
HP1:1
S1
HP1:1
OF TE
TE
X
A
TRENT E BEIGHLE
6
100821
MSS-2
HP1:17
FE
O
S2
HP1:1
TA
R
S1
HP1:1
EM1
HP1:1
F
WP/GFI
HP1:4
PR
X1
HP1:1
S1
HP1:1
EM1
HP1:1
S1
HP1:1
EE
X2
HP1:1
EM1
HP1:1
S
S1
HP1:1
WP/GFI
HP1:4
S
F F
LIC
SS
E NS ED IN
G
IONA L EN
PE-SERVICES
F-10841
EXP: 11/30/12
6
HP1:14 J
HP1:15
UH-1
HP1:16,18
5
MSSI-2
HP1:17
HOUSE
PANEL
"HP1"
FACP
HP1:9
HP1:12
HP1:11
HP1:10
S2
HP1:1
4
3
ARCHITECTURE DEMAREST
WP/GFI
HP1:7
WP/GFI
HP1:7
WP/GFI
HP1:7
WP/GFI
HP1:7
Enlarged BCR/IDF Room - First Floor
Section A1
2
1/4" = 1'-0"
C ARCHITECTURE DEMAREST, L.P.
ALL RIGHTS RESERVED
DATE
07/16/12
Revision Schedule
No. Date
Description
1
Electrical Plan - First Floor Section A1
1/8" = 1'-0"
JOB NO.
10051
SHEET NO.
COPYRIGHT (C) 2011 ARCHITECTURE DEMAREST, L.P. ALL IDEAS, DESIGNS, ARRANGEMENTS, PLANS, AND SPECIFICATIONS INDICATED OR REPRESENTED BY THIS DRAWING AS INSTRUMENTS OF SERVICE ARE AND SHALL REMAIN THE EXCLUSIVE INTELLECTUAL PROPERTY OF ARCHITECTURE DEMAREST, L.P. AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THIS SPECIFIED PROJECT ONLY. NONE OF SUCH
IDEAS, DESIGN, ARRANGEMENTS OR PLANS SHALL BE USED ON ANY OTHER PROJECT OR EXTENSIONS OF THIS PROJECT OR USED BY OR DISCLOSED TO ANY PERSON, FIRM OR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION FORM AND APPROPRIATE COMPENSATION TO ARCHITECTUREDEMAREST, L.P. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. THE CONTRACTOR
SHALL BEAR SOLE RESPONSIBILITY FOR VERIFYING ALL DIMENSIONS ON THIS PROJECT AND NOTIFIYING ARCHITECTURE DEMAREST, L.P. OF ANY DEVIATIONS. THE CONTRACTOR SHALL BEAR SOLE RESPONSIBILITY FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, CONFIRMING COORDINATION AND FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT. ARCHITECTURE DEMAREST, L.P.
WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT.
E111
PLAN NOTES
GENERAL NOTES
A.
ALL WORK SHALL BE IN COMPLIANCE WITH THE MOST CURRENT
EDITION OF THE NATIONAL ELECTRICAL CODE, STATE CODE(S) AND
LOCAL CODE(S).
ELECTRICAL CONTRACTOR SHALL VISIT THE SITE TO FAMILIARIZE
THEMSELVES WITH THE SCOPE OF THE PROJECT PRIOR TO BID.
REFER TO ARCHITECTURAL DRAWINGS FOR WALL AND CEILING
CONSTRUCTION TYPES.
ELECTRICAL DRAWINGS SHOULD NOT BE SCALED, REFER TO
ARCHITECTURAL DRAWINGS AND ADDITIONAL DETAILS CONTAINED
HEREIN FOR DIMENSIONING AND SCALING.
ELECTRICAL WIRING, EQUIPMENT, APPARATUS, ETC. LOCATED ABOVE
CEILINGS SHALL BE LISTED FOR USE IN AIR HANDLING PLENUMS AND
SHALL BE INSTALLED IN ACCORDANCE WITH NEC 300.22. THIS
INCLUDES ALL LOW VOLTAGE CABLING AND EQUIPMENT.
LIGHT SWITCHES SHALL BE INSTALLED IN ACCESSIBLE LOCATIONS NO
HIGHER THAN 42" AFF. ALL SWITCHES IN APARTMENTS SHALL BE
ROCKER TYPE SWITCHES.
B.
BUILDING KEYPLAN
C.
D.
UP
UP
AREA A3
AREA A1
HP2
E.
AREA A2
UP
F.
FACP
4
HP2:20
CLUBHOUSE
UP
MSSI-2
HP2:17 6
HEAT PUMP SERVING RESIDENCES. CIRCUITRY IS SHOWN ON THE TYPICAL RESIDENCE
PLANS. COORDINATE SPECIFIC UNIT WITH MECHANICAL DRAWINGS.
2
PROVIDE ELECTRICAL CONNECTION AND ELECTRICAL CIRCUITRY FOR ELECTRIC UNIT
HEATER. CIRCUITRY SHALL BE AS INDICATED IN THE ELECTRICAL PANEL SCHEDULES.
3
PROVIDE FIRE-RATED PLYWOOD EQUIPMENT BACKBOARD ON BACK AND SIDE WALL OF
ELECTRICAL CLOSET FOR THE MOUNTING OF TELEPHONE, DATA, TELEVISION, FIRE ALARM
AND ELECTRICAL DISTRIBUTION EQUIPMENT. PROVIDE (1) #3 COPPER GROUND WIRE
FROM MAIN GROUNDING ELECTRODE TO EQUIPMENT BACKBOARD. PROVIDE 12"X3"X1/4"
COPPER TERMINATION BAR FOR USE BY THE LOW VOLTAGE SYSTEMS INSTALLER(S).
4
PROVIDE ELECTRICAL CONNECTION AND ELECTRICAL CIRCUITRY FOR FIRE ALARM PANEL.
5
PROVIDE POWER DEVICES AND ELECTRICAL CIRCUITRY AS SHOWN FOR TELEPHONE, DATA,
TELEVISION AND FIRE ALARM EQUIPMENT REQUIREMENTS. VERIFY EXACT LOCATIONS PRIOR
TO ROUGH-IN.
6
PROVIDE ELECTRICAL CONNECTION AND ELECTRICAL CIRCUITRY FOR MINI-SPLIT DEDICATED
SYSTEM. SEE ELECTRICAL PANEL SCHEDULES FOR CIRCUITRY SIZES.
AREA B1
UP
Enlarged CCR/MDF Room - First Floor
Section A2
2
1/4" = 1'-0"
Nacogdoches, TX
LUMBERJACK LOFTS
SFA 1411 ASSOCIATES, L.P.
AREA B2
HP2:9
HP2:10
HP2:11
HP2:12
5
HP2:13
HP2:14
J
HP2:15
2
E112
1
HP1:8
WP/GFI
WP/GFI
HP2:8
HP1:8
WP/GFI
WP/GFI
HP2:8
6
MSSI-1
WP/GFI
HP2:8
MSS-2
HP2:17
PERMIT SET
WP/GFI
HP2:8
Electrical Plan First Floor
Section A2
3
1
J
S1
HP1:1
EM1
HP1:1
S1
HP1:1
HP1:4
WP/GFI
F
S1
HP1:1
EM1
HP1:1
X1
HP2:1
EM1
HP2:1
F
S1
HP2:1
EM1
HP2:1
S1
HP2:1
S1
HP2:1
F
HP2:4
WP/GFI
S1
HP2:1
F
S1
HP2:1
S1
HP2:1
EM1
HP2:1
WP/GFI
HP2:4
S1
HP2:1
EM1
HP2:1
S
WP/GFI
HP2:4
S1
HP2:1
X1
HP2:1
TA
100821
PR
FE
O
X1
HP1:1
2
S1
HP1:1
A
TRENT E BEIGHLE
F
S2
HP1:1
OF TE
TE
X
R
S1
HP1:1
X1
HP1:1
EE
X1
HP1:1
S1
HP1:1
S
S1
HP1:1
EM1
HP1:1
F
EM1
HP1:1
WP/GFI
HP1:4
LIC
SS
E NS ED IN
G
IONA L EN
PE-SERVICES
F-10841
EXP: 11/30/12
UH-1
HP1:19,21
S2
HP1:1
6
MSS-2
HP1:20
ARCHITECTURE DEMAREST
WP/GFI
HP1:7
WP/GFI
HP1:7
HP2:7
WP/GFI
HP2:7
WP/GFI
C ARCHITECTURE DEMAREST, L.P.
ALL RIGHTS RESERVED
HP2:7
WP/GFI
DATE
07/16/12
Revision Schedule
No. Date
Description
1
Electrical Plan - First Floor Section A2
1/8" = 1'-0"
JOB NO.
10051
SHEET NO.
COPYRIGHT (C) 2011 ARCHITECTURE DEMAREST, L.P. ALL IDEAS, DESIGNS, ARRANGEMENTS, PLANS, AND SPECIFICATIONS INDICATED OR REPRESENTED BY THIS DRAWING AS INSTRUMENTS OF SERVICE ARE AND SHALL REMAIN THE EXCLUSIVE INTELLECTUAL PROPERTY OF ARCHITECTURE DEMAREST, L.P. AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THIS SPECIFIED PROJECT ONLY. NONE OF SUCH
IDEAS, DESIGN, ARRANGEMENTS OR PLANS SHALL BE USED ON ANY OTHER PROJECT OR EXTENSIONS OF THIS PROJECT OR USED BY OR DISCLOSED TO ANY PERSON, FIRM OR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION FORM AND APPROPRIATE COMPENSATION TO ARCHITECTUREDEMAREST, L.P. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. THE CONTRACTOR
SHALL BEAR SOLE RESPONSIBILITY FOR VERIFYING ALL DIMENSIONS ON THIS PROJECT AND NOTIFIYING ARCHITECTURE DEMAREST, L.P. OF ANY DEVIATIONS. THE CONTRACTOR SHALL BEAR SOLE RESPONSIBILITY FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, CONFIRMING COORDINATION AND FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT. ARCHITECTURE DEMAREST, L.P.
WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT.
E112
GENERAL NOTES
A.
B.
BUILDING KEYPLAN
C.
D.
UP
UP
AREA A3
AREA A1
E.
AREA A2
UP
F.
CLUBHOUSE
UP
WP/GFI
HP2:4
ALL WORK SHALL BE IN COMPLIANCE WITH THE MOST CURRENT
EDITION OF THE NATIONAL ELECTRICAL CODE, STATE CODE(S) AND
LOCAL CODE(S).
ELECTRICAL CONTRACTOR SHALL VISIT THE SITE TO FAMILIARIZE
THEMSELVES WITH THE SCOPE OF THE PROJECT PRIOR TO BID.
REFER TO ARCHITECTURAL DRAWINGS FOR WALL AND CEILING
CONSTRUCTION TYPES.
ELECTRICAL DRAWINGS SHOULD NOT BE SCALED, REFER TO
ARCHITECTURAL DRAWINGS AND ADDITIONAL DETAILS CONTAINED
HEREIN FOR DIMENSIONING AND SCALING.
ELECTRICAL WIRING, EQUIPMENT, APPARATUS, ETC. LOCATED ABOVE
CEILINGS SHALL BE LISTED FOR USE IN AIR HANDLING PLENUMS AND
SHALL BE INSTALLED IN ACCORDANCE WITH NEC 300.22. THIS
INCLUDES ALL LOW VOLTAGE CABLING AND EQUIPMENT.
LIGHT SWITCHES SHALL BE INSTALLED IN ACCESSIBLE LOCATIONS NO
HIGHER THAN 42" AFF. ALL SWITCHES IN APARTMENTS SHALL BE
ROCKER TYPE SWITCHES.
PLAN NOTES
1
HEAT PUMP SERVING RESIDENCES. CIRCUITRY IS SHOWN ON THE TYPICAL RESIDENCE
PLANS. COORDINATE SPECIFIC UNIT WITH MECHANICAL DRAWINGS.
2
PROVIDE ELECTRICAL CONNECTION AND ELECTRICAL CIRCUITRY FOR ELECTRIC UNIT
HEATER. CIRCUITRY SHALL BE AS INDICATED IN THE ELECTRICAL PANEL SCHEDULES.
AREA B1
AREA B2
HP2:8
WP/GFI
F
X1
HP2:1
S1
HP2:1
EM1
HP2:1
WP/GFI
HP2:4
HP2:8
WP/GFI
PERMIT SET
S1
HP2:1
Electrical Plan First Floor
Section A3
S1
HP2:1
Nacogdoches, TX
UP
EM1
HP2:1
LUMBERJACK LOFTS
SFA 1411 ASSOCIATES, L.P.
S1
HP2:1
EM1
HP2:1
S1
HP2:1
F
WP/GFI
WP/GFI
HP2:4
S
EM1
HP2:1
TA
OF TE
TE
X
A
S
S1
HP2:1
TRENT E BEIGHLE
O
FE
EE
PR
R
100821
LIC
SS
E NS ED IN
G
IONA L EN
PE-SERVICES
F-10841
EXP: 11/30/12
S1
HP2:1
WP/GFI
WP/GFI
EM1
HP2:1
WP/GFI
HP2:4
ARCHITECTURE DEMAREST
S1
HP2:1
C ARCHITECTURE DEMAREST, L.P.
ALL RIGHTS RESERVED
F F
X1
HP2:1
1
UH-1
S2
HP2:16,18 HP2:1
S2
HP2:1
DATE
WP/GFI
X1
HP2:1
Electrical Plan - First Floor Section A3
1/8" = 1'-0"
07/16/12
Revision Schedule
No. Date
Description
JOB NO.
10051
SHEET NO.
COPYRIGHT (C) 2011 ARCHITECTURE DEMAREST, L.P. ALL IDEAS, DESIGNS, ARRANGEMENTS, PLANS, AND SPECIFICATIONS INDICATED OR REPRESENTED BY THIS DRAWING AS INSTRUMENTS OF SERVICE ARE AND SHALL REMAIN THE EXCLUSIVE INTELLECTUAL PROPERTY OF ARCHITECTURE DEMAREST, L.P. AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THIS SPECIFIED PROJECT ONLY. NONE OF SUCH
IDEAS, DESIGN, ARRANGEMENTS OR PLANS SHALL BE USED ON ANY OTHER PROJECT OR EXTENSIONS OF THIS PROJECT OR USED BY OR DISCLOSED TO ANY PERSON, FIRM OR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION FORM AND APPROPRIATE COMPENSATION TO ARCHITECTUREDEMAREST, L.P. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. THE CONTRACTOR
SHALL BEAR SOLE RESPONSIBILITY FOR VERIFYING ALL DIMENSIONS ON THIS PROJECT AND NOTIFIYING ARCHITECTURE DEMAREST, L.P. OF ANY DEVIATIONS. THE CONTRACTOR SHALL BEAR SOLE RESPONSIBILITY FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, CONFIRMING COORDINATION AND FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT. ARCHITECTURE DEMAREST, L.P.
WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT.
E113
PLAN NOTES
GENERAL NOTES
A.
B.
BUILDING KEYPLAN
C.
D.
UP
UP
AREA A3
6
AREA A1
E.
AREA A2
UP
MSS-2
HP3:16
F.
CLUBHOUSE
UP
MSSI-2
6
HP3:16
1
HEAT PUMP SERVING RESIDENCES. CIRCUITRY IS SHOWN ON THE TYPICAL RESIDENCE
PLANS. COORDINATE SPECIFIC UNIT WITH MECHANICAL DRAWINGS.
2
PROVIDE ELECTRICAL CONNECTION AND ELECTRICAL CIRCUITRY FOR ELECTRIC UNIT HEATER.
CIRCUITRY SHALL BE AS INDICATED IN THE ELECTRICAL PANEL SCHEDULES.
3
PROVIDE FIRE-RATED PLYWOOD EQUIPMENT BACKBOARD ON BACK AND SIDE WALL OF
ELECTRICAL CLOSET FOR THE MOUNTING OF TELEPHONE, DATA, TELEVISION, FIRE ALARM AND
ELECTRICAL DISTRIBUTION EQUIPMENT. PROVIDE (1) #3 COPPER GROUND WIRE FROM MAIN
GROUNDING ELECTRODE TO EQUIPMENT BACKBOARD. PROVIDE 12"X3"X1/4" COPPER
TERMINATION BAR FOR USE BY THE LOW VOLTAGE SYSTEMS INSTALLER(S).
4
PROVIDE ELECTRICAL CONNECTION AND ELECTRICAL CIRCUITRY FOR FIRE ALARM PANEL.
5
PROVIDE POWER DEVICES AND ELECTRICAL CIRCUITRY AS SHOWN FOR TELEPHONE, DATA,
TELEVISION AND FIRE ALARM EQUIPMENT REQUIREMENTS. VERIFY EXACT LOCATIONS PRIOR
TO ROUGH-IN.
6
PROVIDE ELECTRICAL CONNECTION AND ELECTRICAL CIRCUITRY FOR MINI-SPLIT DEDICATED
SYSTEM. SEE ELECTRICAL PANEL SCHEDULES FOR CIRCUITRY SIZES.
AREA B1
AREA B2
LUMBERJACK LOFTS
SFA 1411 ASSOCIATES, L.P.
HOUSE
PANEL
"HP3"
UP
HP3:12
HP3:11
HP3:10
5
FACP
HP3:9
4
3
Enlarged BCR/IDF Room - First Floor
Section B1
2
1/4" = 1'-0"
Nacogdoches, TX
HP3:14
HP3:15 J
ALL WORK SHALL BE IN COMPLIANCE WITH THE MOST CURRENT
EDITION OF THE NATIONAL ELECTRICAL CODE, STATE CODE(S) AND
LOCAL CODE(S).
ELECTRICAL CONTRACTOR SHALL VISIT THE SITE TO FAMILIARIZE
THEMSELVES WITH THE SCOPE OF THE PROJECT PRIOR TO BID.
REFER TO ARCHITECTURAL DRAWINGS FOR WALL AND CEILING
CONSTRUCTION TYPES.
ELECTRICAL DRAWINGS SHOULD NOT BE SCALED, REFER TO
ARCHITECTURAL DRAWINGS AND ADDITIONAL DETAILS CONTAINED
HEREIN FOR DIMENSIONING AND SCALING.
ELECTRICAL WIRING, EQUIPMENT, APPARATUS, ETC. LOCATED ABOVE
CEILINGS SHALL BE LISTED FOR USE IN AIR HANDLING PLENUMS AND
SHALL BE INSTALLED IN ACCORDANCE WITH NEC 300.22. THIS
INCLUDES ALL LOW VOLTAGE CABLING AND EQUIPMENT.
LIGHT SWITCHES SHALL BE INSTALLED IN ACCESSIBLE LOCATIONS NO
HIGHER THAN 42" AFF. ALL SWITCHES IN APARTMENTS SHALL BE
ROCKER TYPE SWITCHES.
PERMIT SET
S1
HP3:1
HP3:4
WP/GFI
S1
HP3:1
S1
HP3:1
WP/GFI
HP3:4
S1
HP3:1
EM1
HP3:1
S1
HP3:1
S1
HP3:1
F
EM1
HP3:1
WP/GFI
HP3:4
S1
HP3:1
HP3:4
WP/GFI
S1
HP3:1
EM1
HP3:1
S1
HP3:1
S1
HP3:1
EM1
HP3:1
X1
HP3:1
S1
HP3:1
A
TRENT E BEIGHLE
100821
FE
O
EM1
HP3:1
S1
HP3:1
EM1
HP3:1
OF TE
TE
X
R
F
PR
X1
HP3:1
WP/GFI
EM1
HP3:4 HP3:1
X1
F
HP3:1
F
TA
S
S1
HP3:1
F
S
J
EE
2
E114
HP3:8
WP/GFI
WP/GFI
WP/GFI
HP3:8
WP/GFI
Electrical Plan First Floor
Section B1
1
LIC
SS
E NS ED IN
G
IONA L EN
S2
HP3:1
PE-SERVICES
F-10841
EXP: 11/30/12
UH-1
HP3:17,19
2
S2
HP3:1
ARCHITECTURE DEMAREST
C ARCHITECTURE DEMAREST, L.P.
ALL RIGHTS RESERVED
WP/GFI
HP3:7
DATE
WP/GFI
HP3:7
WP/GFI
HP3:7
WP/GFI
HP3:7
WP/GFI
HP3:7
07/16/12
Revision Schedule
No. Date
Description
1
Electrical Plan - First Floor Section B1
1/8" = 1'-0"
JOB NO.
10051
SHEET NO.
COPYRIGHT (C) 2011 ARCHITECTURE DEMAREST, L.P. ALL IDEAS, DESIGNS, ARRANGEMENTS, PLANS, AND SPECIFICATIONS INDICATED OR REPRESENTED BY THIS DRAWING AS INSTRUMENTS OF SERVICE ARE AND SHALL REMAIN THE EXCLUSIVE INTELLECTUAL PROPERTY OF ARCHITECTURE DEMAREST, L.P. AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THIS SPECIFIED PROJECT ONLY. NONE OF SUCH
IDEAS, DESIGN, ARRANGEMENTS OR PLANS SHALL BE USED ON ANY OTHER PROJECT OR EXTENSIONS OF THIS PROJECT OR USED BY OR DISCLOSED TO ANY PERSON, FIRM OR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION FORM AND APPROPRIATE COMPENSATION TO ARCHITECTUREDEMAREST, L.P. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. THE CONTRACTOR
SHALL BEAR SOLE RESPONSIBILITY FOR VERIFYING ALL DIMENSIONS ON THIS PROJECT AND NOTIFIYING ARCHITECTURE DEMAREST, L.P. OF ANY DEVIATIONS. THE CONTRACTOR SHALL BEAR SOLE RESPONSIBILITY FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, CONFIRMING COORDINATION AND FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT. ARCHITECTURE DEMAREST, L.P.
WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT.
E114
GENERAL NOTES
A.
B.
BUILDING KEYPLAN
C.
D.
UP
AREA A3
REF.
X1
HP3:1
HP3:8
AREA A2
X1
HP3:1
S2
HP3:1
S1
HP3:1
HP3:4
WP/GFI
AREA A1
E.
UP
F F
EM1
HP3:1
UP
UH-1 2
HP3:18,20
F.
CLUBHOUSE
UP
S2
HP3:1
WP/GFI
HP3:7
ALL WORK SHALL BE IN COMPLIANCE WITH THE MOST CURRENT
EDITION OF THE NATIONAL ELECTRICAL CODE, STATE CODE(S) AND
LOCAL CODE(S).
ELECTRICAL CONTRACTOR SHALL VISIT THE SITE TO FAMILIARIZE
THEMSELVES WITH THE SCOPE OF THE PROJECT PRIOR TO BID.
REFER TO ARCHITECTURAL DRAWINGS FOR WALL AND CEILING
CONSTRUCTION TYPES.
ELECTRICAL DRAWINGS SHOULD NOT BE SCALED, REFER TO
ARCHITECTURAL DRAWINGS AND ADDITIONAL DETAILS CONTAINED
HEREIN FOR DIMENSIONING AND SCALING.
ELECTRICAL WIRING, EQUIPMENT, APPARATUS, ETC. LOCATED ABOVE
CEILINGS SHALL BE LISTED FOR USE IN AIR HANDLING PLENUMS AND
SHALL BE INSTALLED IN ACCORDANCE WITH NEC 300.22. THIS
INCLUDES ALL LOW VOLTAGE CABLING AND EQUIPMENT.
LIGHT SWITCHES SHALL BE INSTALLED IN ACCESSIBLE LOCATIONS NO
HIGHER THAN 42" AFF. ALL SWITCHES IN APARTMENTS SHALL BE
ROCKER TYPE SWITCHES.
PLAN NOTES
1
HEAT PUMP SERVING RESIDENCES. CIRCUITRY IS SHOWN ON THE TYPICAL RESIDENCE
PLANS. COORDINATE SPECIFIC UNIT WITH MECHANICAL DRAWINGS.
2
PROVIDE ELECTRICAL CONNECTION AND ELECTRICAL CIRCUITRY FOR ELECTRIC UNIT
HEATER. CIRCUITRY SHALL BE AS INDICATED IN THE ELECTRICAL PANEL SCHEDULES.
3
PROVIDE FIRE-RATED PLYWOOD EQUIPMENT BACKBOARD ON BACK AND SIDE WALL OF
ELECTRICAL CLOSET FOR THE MOUNTING OF TELEPHONE, DATA, TELEVISION, FIRE ALARM
AND ELECTRICAL DISTRIBUTION EQUIPMENT. PROVIDE (1) #3 COPPER GROUND WIRE FROM
MAIN GROUNDING ELECTRODE TO EQUIPMENT BACKBOARD. PROVIDE 12"X3"X1/4" COPPER
TERMINATION BAR FOR USE BY THE LOW VOLTAGE SYSTEMS INSTALLER(S).
4
PROVIDE ELECTRICAL CONNECTION AND ELECTRICAL CIRCUITRY FOR FIRE ALARM PANEL.
5
PROVIDE POWER DEVICES AND ELECTRICAL CIRCUITRY AS SHOWN FOR TELEPHONE, DATA,
TELEVISION AND FIRE ALARM EQUIPMENT REQUIREMENTS. VERIFY EXACT LOCATIONS PRIOR
TO ROUGH-IN.
6
PROVIDE ELECTRICAL CONNECTION AND ELECTRICAL CIRCUITRY FOR MINI-SPLIT DEDICATED
SYSTEM. SEE ELECTRICAL PANEL SCHEDULES FOR CIRCUITRY SIZES.
AREA B1
AREA B2
UP
S1
HP3:1
1
EM1
HP3:1
S1
HP3:1
HP3:7
WP/GFI
WP/GFI
WP/GFI
F
Nacogdoches, TX
LUMBERJACK LOFTS
SFA 1411 ASSOCIATES, L.P.
WP/GFI
Electrical Plan First Floor
Section B2
S1
HP3:1
PERMIT SET
EM1
HP3:1
WP/GFI
HP3:4
S1
HP3:1
HP3:7
WP/GFI
EM1
HP3:1
TA
OF TE
TE
X
A
S
S
S1
HP3:1
TRENT E BEIGHLE
O
FE
EE
PR
R
100821
F
LIC
SS
E NS ED IN
G
IONA L EN
S1
HP3:1 HP3:4
WP/GFI
2
E115
S1
EM1 HP3:1
HP3:1
PE-SERVICES
F-10841
EXP: 11/30/12
HP3:7
WP/GFI
J
HP3:4
WP/GFI
ARCHITECTURE DEMAREST
HP3:26
HP3:24
HP3:22
X1
HP3:1
C ARCHITECTURE DEMAREST, L.P.
ALL RIGHTS RESERVED
3
DATE
5
HP3:30
HP3:28 J
MSS-2
HP3:32
Electrical Plan - First Floor Section B2
1
1/8" = 1'-0"
FACP
HP3:13
MSSI-2
HP3:32
4
07/16/12
6
Revision Schedule
No. Date
Description
6
Enlarged BCR/IDF Electrical Plan - First
Floor Section B2
2
1/4" = 1'-0"
JOB NO.
10051
SHEET NO.
COPYRIGHT (C) 2011 ARCHITECTURE DEMAREST, L.P. ALL IDEAS, DESIGNS, ARRANGEMENTS, PLANS, AND SPECIFICATIONS INDICATED OR REPRESENTED BY THIS DRAWING AS INSTRUMENTS OF SERVICE ARE AND SHALL REMAIN THE EXCLUSIVE INTELLECTUAL PROPERTY OF ARCHITECTURE DEMAREST, L.P. AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THIS SPECIFIED PROJECT ONLY. NONE OF SUCH
IDEAS, DESIGN, ARRANGEMENTS OR PLANS SHALL BE USED ON ANY OTHER PROJECT OR EXTENSIONS OF THIS PROJECT OR USED BY OR DISCLOSED TO ANY PERSON, FIRM OR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION FORM AND APPROPRIATE COMPENSATION TO ARCHITECTUREDEMAREST, L.P. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. THE CONTRACTOR
SHALL BEAR SOLE RESPONSIBILITY FOR VERIFYING ALL DIMENSIONS ON THIS PROJECT AND NOTIFIYING ARCHITECTURE DEMAREST, L.P. OF ANY DEVIATIONS. THE CONTRACTOR SHALL BEAR SOLE RESPONSIBILITY FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, CONFIRMING COORDINATION AND FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT. ARCHITECTURE DEMAREST, L.P.
WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT.
E115
LIGHT FIXTURE SCHEDULE - CLUBHOUSE
SYMBOL
L1
DESCRIPTION
SYMBOL
DESCRIPTION
BATH VANITY SCONCE. TBD. EST COST $250 EA.
RECESSED COMPACT FLUORESCENT DOWN LIGHT (FOR A FLAT
CEILING)
L2
BUILDING KEYPLAN
UP
L11
COMPACT FLUORESCENT DOWNLIGHT (FOR SLOPE CEILING)
L12
UP
AREA A3
10" X 24" SURFACE MOUNT LIGHT W ACRYLIC WRAP AROUND
LENS/ UTILITY FUNCTION
AREA A1
AREA A2
UP
L6
PENDANT (POOL TABLE & FOOSBALL TABLE)
MFR: TBD, COLOR: TBD, HEIGHT: 0", DIA:0". EST COST $250 EA
L14
UP
CURVED TRACK LIGHT W/ 4 FIXTURES (LEASING)
AREA B1
L15
AREA B2
INDICATES LOCATION OF J-BOX IN CEILING
L8
L9
L10
L16
8' TRACK LIGHT W 3-4 FIXTURES AS INDICATED ON PLAN (CLUB
ROOM)
CEILING FAN W/ LIGHT KIT (FITNESS AND CLUB RM)
MFR: HUNTER, 52" BRUSHED NICKEL CEILILNG FAN. MODEL
#28737. EST COST $200 EA
UP
INDICATES LOCATION OF J-BOX IN CEILING
8' LINEAR SUSPENDED PENDANT (OFFICE, GROUP STUDY)
MFR: CORELITE, CLASS A FULL PERF, SEMI-INDIRECT, STANDARD
FLAT END PLATE (AZ-WP), WHITE, 9" x 96", (2) T5 OR (2) T5HO OR
(2) T8. APPROX COST: $
12' LINEAR SUSPENDED PENDANT (FITNESS)
MFR: CORELITE, CLASS A FULL PERF, SEMI-INDIRECT, STANDARD
FLAT END PLATE (AZ-WP), WHITE, 9" x 144", (2) T5 OR (2) T5HO OR
(2) T8. APPROX COST: $
GENERAL NOTES
A.
B.
C.
D.
E.
F.
EM1
PQLA:6
ALL WORK SHALL BE IN COMPLIANCE WITH THE MOST CURRENT EDITION OF THE NATIONAL
ELECTRICAL CODE, STATE CODE(S) AND LOCAL CODE(S).
ELECTRICAL CONTRACTOR SHALL VISIT THE SITE TO FAMILIARIZE THEMSELVES WITH THE SCOPE
OF THE PROJECT PRIOR TO BID.
REFER TO ARCHITECTURAL DRAWINGS FOR WALL AND CEILING CONSTRUCTION TYPES.
ELECTRICAL DRAWINGS SHOULD NOT BE SCALED, REFER TO ARCHITECTURAL DRAWINGS AND
ADDITIONAL DETAILS CONTAINED HEREIN FOR DIMENSIONING AND SCALING.
ELECTRICAL WIRING, EQUIPMENT, APPARATUS, ETC. LOCATED ABOVE CEILINGS SHALL BE LISTED
FOR USE IN AIR HANDLING PLENUMS AND SHALL BE INSTALLED IN ACCORDANCE WITH NEC
300.22. THIS INCLUDES ALL LOW VOLTAGE CABLING AND EQUIPMENT.
LIGHT SWITCHES SHALL BE INSTALLED IN ACCESSIBLE LOCATIONS NO HIGHER THAN 42" AFF.
ALL SWITCHES IN APARTMENTS SHALL BE ROKER TYPE SWITCHES.
V
PQLA:6
EX. FAN
PQLA:6
L8
CH:56
L8
CH:56
L10
CH:54
L10
CH:54
L8
CH:56
L2
CH:59
FITNESS RM
X1
CH:58
L2
CH:58
L6
CH:57
L2
CH:58
L2
CH:58
L2
CH:58
L6
CH:57
L6
CH:57
COMMUNITY
SPACE
L4
CH:57
L2
CH:58
L2
CH:58
L2
CH:58
L2
CH:58
L2
CH:58
L5
CH:57
L5
CH:57
L5
CH:57
L16 J
CH:40
4
L14
CH:58
L1
CH:59
L2
CH:59
L16 J
CH:44
L1
CH:59
EM1
CH:59
L2
CH:59
L7
CH:59
L1
CH:59
L11
L14
CH:58
L11
CH:59
L1
CH:59
L1
CH:59
EM1
CH:59
L1
CH:59
4
WOMEN
L1
CH:59
PERMIT SET
X1
CH:59
L2
CORRIDORCH:59
L1
CH:59
L1
CH:59
X1
CH:59
L1
CH:59
L1
CH:59
LEASING OFFICE
L14
CH:61
L14
CH:61
L14
CH:61
L2
CH:61
L3
CH:60
L3
CH:60
L7
CH:61
L1
CH:61
L1
CH:61
L1
CH:61
L1
CH:61
WORK RM
L2
CH:61
L2
CH:61
L2
CH:61
L14
CH:61
L14
CH:61
J L15
CH:60
L2
CH:61
L7
CH:61
3
L4
CH:60
L3
CH:60
MAIL ROOM
L7 3
CH:59
MEN
L14
L2
CH:58 CH:58
L2
CH:58
L2
CH:58
L2
CH:59
JAN
L1
CH:59
L4
CH:60
L3
CH:60
L9
CH:61
L9
CH:61
ASST. MGR.
3
L2
CH:61
L1
CH:61
L2
CH:61
X1
CH:61
L1
CH:61
L1
CH:61
L2
TA
OF TE
TE
X
A
TRENT E BEIGHLE
100821
X1
CH:61
FE
O
L6
CH:57
P.C. CENTER
L1
CH:59
L1
CH:59
L1
CH:59
PR
L2
CH:58
REF.
L2
CH:58
L1
CH:59
L12
CH:54
Pool Equipment Room and Restrooms
1/4" = 1'-0"
L3
CH:60
L13
CH:54
L1
CH:59
EX. FAN
PQLA:6
EX. FAN
PQLA:6
S
L2
CH:58
L10
CH:54
L1
CH:59
REF.
L10
CH:54
ELEC/MDF
L10
CH:54
3
V
PQLA:6
B1
PQLA:6
4
L10
CH:54
EM1
PQLA:6
S
L7
8' LINEAR WALL MOUNT (SKYLIGHT)
MFR: CORELITE, ELEMENT MICRO WALL MOUNT WITH MICRO
PRISMATIC LENS (E1W-WM), MOUNTED 8'-0" O.C. AFF. EST $ EA
Nacogdoches, TX
L5
PENDANT (COMMUNITY ROOM- DINING AREA)
MFR: TBD, COLOR: TBD, HEIGHT: 0", DIA: 0". EST COST $250 EA
LED UNDERCABINET LIGHT. UTILITECH 24" LED HARDWIRED
CABINET LIGHT BAR KIT. LOWES ITEM #331390. MODEL #
GU0724DW-WH-1. COST $70 EA.
R
PENDANT (LEASING AND COMMUNITY RM )
MFR: TBD, COLOR: TBD, HEIGHT: 0", DIA: 0" . EST COST $250 EA
CLUBHOUSE
EE
L4
L13
LUMBERJACK LOFTS
SFA 1411 ASSOCIATES, L.P.
PENDANT (LEASING DESK + ONLINE LEASING)
MFR: TBD, COLOR: TBD, HEIGHT: 0", DIA: 0", EST. COST $150 EA
Electrical Lighting
Plan - Clubhouse
and Maintenance
Building
L3
10" X 48" SURFACE MOUNT LIGHT W ACRYLIC WRAP AROUND
LENS/ UTILITY FUNCTION
LIC
SS
E NS ED IN
G
IONA L EN
CH:61
PE-SERVICES
F-10841
EXP: 11/30/12
L9
CH:61
L9
CH:61
MANAGER
ARCHITECTURE DEMAREST
B2
MB1:12
C ARCHITECTURE DEMAREST, L.P.
ALL RIGHTS RESERVED
DATE
07/16/12
B1
MB1:12
B1
MB1:12
B1
MB1:12
B1
MB1:12
1
Electrical Lighting Plan - Clubhouse
1/8" = 1'-0"
Revision Schedule
No. Date
Description
Electrical Lighting Plan - Maintenance
Building
2
1/8" = 1'-0"
JOB NO.
10051
SHEET NO.
COPYRIGHT (C) 2011 ARCHITECTURE DEMAREST, L.P. ALL IDEAS, DESIGNS, ARRANGEMENTS, PLANS, AND SPECIFICATIONS INDICATED OR REPRESENTED BY THIS DRAWING AS INSTRUMENTS OF SERVICE ARE AND SHALL REMAIN THE EXCLUSIVE INTELLECTUAL PROPERTY OF ARCHITECTURE DEMAREST, L.P. AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THIS SPECIFIED PROJECT ONLY. NONE OF SUCH
IDEAS, DESIGN, ARRANGEMENTS OR PLANS SHALL BE USED ON ANY OTHER PROJECT OR EXTENSIONS OF THIS PROJECT OR USED BY OR DISCLOSED TO ANY PERSON, FIRM OR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION FORM AND APPROPRIATE COMPENSATION TO ARCHITECTUREDEMAREST, L.P. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. THE CONTRACTOR
SHALL BEAR SOLE RESPONSIBILITY FOR VERIFYING ALL DIMENSIONS ON THIS PROJECT AND NOTIFIYING ARCHITECTURE DEMAREST, L.P. OF ANY DEVIATIONS. THE CONTRACTOR SHALL BEAR SOLE RESPONSIBILITY FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, CONFIRMING COORDINATION AND FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT. ARCHITECTURE DEMAREST, L.P.
WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT.
E116
GENERAL NOTES
BUILDING KEYPLAN
A.
B.
UP
C.
D.
UP
AREA A3
AREA A1
E.
AREA A2
UP
F.
CLUBHOUSE
ALL WORK SHALL BE IN COMPLIANCE WITH THE MOST CURRENT EDITION OF THE NATIONAL
ELECTRICAL CODE, STATE CODE(S) AND LOCAL CODE(S).
ELECTRICAL CONTRACTOR SHALL VISIT THE SITE TO FAMILIARIZE THEMSELVES WITH THE SCOPE
OF THE PROJECT PRIOR TO BID.
REFER TO ARCHITECTURAL DRAWINGS FOR WALL AND CEILING CONSTRUCTION TYPES.
ELECTRICAL DRAWINGS SHOULD NOT BE SCALED, REFER TO ARCHITECTURAL DRAWINGS AND
ADDITIONAL DETAILS CONTAINED HEREIN FOR DIMENSIONING AND SCALING.
ELECTRICAL WIRING, EQUIPMENT, APPARATUS, ETC. LOCATED ABOVE CEILINGS SHALL BE LISTED
FOR USE IN AIR HANDLING PLENUMS AND SHALL BE INSTALLED IN ACCORDANCE WITH NEC
300.22. THIS INCLUDES ALL LOW VOLTAGE CABLING AND EQUIPMENT.
LIGHT SWITCHES SHALL BE INSTALLED IN ACCESSIBLE LOCATIONS NO HIGHER THAN 42" AFF.
ALL SWITCHES IN APARTMENTS SHALL BE ROKER TYPE SWITCHES.
UP
AREA B1
WP1
HP1:35
WP1
HP1:35
PERMIT SET
WP1
HP1:35
Electrical Plan Second Floor
Section A1
UP
Nacogdoches, TX
LUMBERJACK LOFTS
SFA 1411 ASSOCIATES, L.P.
AREA B2
S1
HP1:2
S1
HP1:2
S1
HP1:2
EM1
HP1:2
S1
HP1:2
S1
HP1:2
EM1
HP1:2
HP1:5
WP/GFI
F
S1
HP1:2
EM1
HP1:2
F
WP/GFI
HP1:5
S1
HP1:2
EM1
HP1:2
S1
HP1:2
S1
HP1:2
HP1:5
WP/GFI
S1
HP1:2
S1
HP1:2
F
EM1
HP1:2
TA
OF TE
TE
X
A
TRENT E BEIGHLE
100821
PR
R
X2
HP1:2
EM1
HP1:2
S
S1
HP1:2
WP/GFI
HP1:5
S2
HP1:2
O
FE
EE
F F
S
S1
HP1:2
LIC
SS
E NS ED IN
G
IONA L EN
PE-SERVICES
F-10841
EXP: 11/30/12
WP1
HP1:35
S2
HP1:2
ARCHITECTURE DEMAREST
WP1
HP1:35
C ARCHITECTURE DEMAREST, L.P.
ALL RIGHTS RESERVED
DATE
07/16/12
Revision Schedule
No. Date
Description
1
Electrical Plan - Second Floor Section A1
1/8" = 1'-0"
JOB NO.
10051
SHEET NO.
COPYRIGHT (C) 2011 ARCHITECTURE DEMAREST, L.P. ALL IDEAS, DESIGNS, ARRANGEMENTS, PLANS, AND SPECIFICATIONS INDICATED OR REPRESENTED BY THIS DRAWING AS INSTRUMENTS OF SERVICE ARE AND SHALL REMAIN THE EXCLUSIVE INTELLECTUAL PROPERTY OF ARCHITECTURE DEMAREST, L.P. AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THIS SPECIFIED PROJECT ONLY. NONE OF SUCH
IDEAS, DESIGN, ARRANGEMENTS OR PLANS SHALL BE USED ON ANY OTHER PROJECT OR EXTENSIONS OF THIS PROJECT OR USED BY OR DISCLOSED TO ANY PERSON, FIRM OR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION FORM AND APPROPRIATE COMPENSATION TO ARCHITECTUREDEMAREST, L.P. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. THE CONTRACTOR
SHALL BEAR SOLE RESPONSIBILITY FOR VERIFYING ALL DIMENSIONS ON THIS PROJECT AND NOTIFIYING ARCHITECTURE DEMAREST, L.P. OF ANY DEVIATIONS. THE CONTRACTOR SHALL BEAR SOLE RESPONSIBILITY FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, CONFIRMING COORDINATION AND FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT. ARCHITECTURE DEMAREST, L.P.
WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT.
E121
GENERAL NOTES
BUILDING KEYPLAN
A.
ALL WORK SHALL BE IN COMPLIANCE WITH THE MOST CURRENT EDITION OF THE NATIONAL
ELECTRICAL CODE, STATE CODE(S) AND LOCAL CODE(S).
ELECTRICAL CONTRACTOR SHALL VISIT THE SITE TO FAMILIARIZE THEMSELVES WITH THE SCOPE
OF THE PROJECT PRIOR TO BID.
REFER TO ARCHITECTURAL DRAWINGS FOR WALL AND CEILING CONSTRUCTION TYPES.
ELECTRICAL DRAWINGS SHOULD NOT BE SCALED, REFER TO ARCHITECTURAL DRAWINGS AND
ADDITIONAL DETAILS CONTAINED HEREIN FOR DIMENSIONING AND SCALING.
ELECTRICAL WIRING, EQUIPMENT, APPARATUS, ETC. LOCATED ABOVE CEILINGS SHALL BE LISTED
FOR USE IN AIR HANDLING PLENUMS AND SHALL BE INSTALLED IN ACCORDANCE WITH NEC
300.22. THIS INCLUDES ALL LOW VOLTAGE CABLING AND EQUIPMENT.
LIGHT SWITCHES SHALL BE INSTALLED IN ACCESSIBLE LOCATIONS NO HIGHER THAN 42" AFF.
ALL SWITCHES IN APARTMENTS SHALL BE ROKER TYPE SWITCHES.
B.
UP
C.
D.
UP
AREA A3
AREA A1
E.
AREA A2
UP
F.
CLUBHOUSE
1
UP
4
HP2:31
HP2:33
HP2:35
PROVIDE FIRE-RATED PLYWOOD EQUIPMENT BACKBOARD ON BACK AND SIDE WALL OF
ELECTRICAL CLOSET FOR THE MOUNTING OF TELEPHONE, DATA, TELEVISION, FIRE ALARM
AND ELECTRICAL DISTRIBUTION EQUIPMENT. PROVIDE (1) #3 COPPER GROUND WIRE
FROM MAIN GROUNDING ELECTRODE TO EQUIPMENT BACKBOARD. PROVIDE
12"X3"X1/4" COPPER TERMINATION BAR FOR USE BY THE LOW VOLTAGE SYSTEMS
INSTALLER(S).
2
PROVIDE ELECTRICAL CONNECTION AND ELECTRICAL CIRCUITRY FOR FIRE ALARM PANEL.
3
PROVIDE POWER DEVICES AND ELECTRICAL CIRCUITRY AS SHOWN FOR TELEPHONE, DATA,
TELEVISION AND FIRE ALARM EQUIPMENT REQUIREMENTS. VERIFY EXACT LOCATIONS
PRIOR TO ROUGH-IN.
4
PROVIDE ELECTRICAL CONNECTION AND ELECTRICAL CIRCUITRY FOR MINI-SPLIT
DEDICATED SYSTEM. SEE ELECTRICAL PANEL SCHEDULES FOR CIRCUITRY SIZES.
UP
Enlarged BCR/IDF Room - Second Floor
Section A2
2
1/4" = 1'-0"
X1
HP1:2
EM1
HP1:2
S1
HP1:2
S1
HP1:2
EM1
HP1:2
S1
HP1:2
HP1:5
WP/GFI
F
S1
HP1:2
S1
HP1:2
EM1
HP1:2
X1
HP1:2
WP/GFI
HP2:5
X1
HP2:2
F
F
S1
HP2:2
S1
HP2:2
S1
HP2:2
F
HP2:5
WP/GFI
S1
HP2:2
S1
HP2:2
S1
HP2:2
WP/GFI
HP2:5
S1
HP2:2
S1
HP2:2
X1
HP2:2
TA
100821
PR
O
S2
HP1:2
A
TRENT E BEIGHLE
F
FE
S1
HP1:2
OF TE
TE
X
R
S1
HP1:2
F
S
EM1
HP1:2
S
PERMIT SET
WP1
HP2:25
WP/GFI
HP1:5
Nacogdoches, TX
3
1
EE
HP2:39
HP2:37 J
AREA B2
LUMBERJACK LOFTS
SFA 1411 ASSOCIATES, L.P.
PLAN NOTES
AREA B1
FACP 2
HP2:41
Electrical Plan Second Floor
Section A2
MSSI-2
HP1:20
LIC
SS
E NS ED IN
G
IONA L EN
PE-SERVICES
F-10841
EXP: 11/30/12
J
S2
HP1:2
2
E122
ARCHITECTURE DEMAREST
WP1
HP2:25
C ARCHITECTURE DEMAREST, L.P.
ALL RIGHTS RESERVED
DATE
07/16/12
Revision Schedule
No. Date
Description
1
Electrical Plan - Second Floor Section A2
1/8" = 1'-0"
JOB NO.
10051
SHEET NO.
COPYRIGHT (C) 2011 ARCHITECTURE DEMAREST, L.P. ALL IDEAS, DESIGNS, ARRANGEMENTS, PLANS, AND SPECIFICATIONS INDICATED OR REPRESENTED BY THIS DRAWING AS INSTRUMENTS OF SERVICE ARE AND SHALL REMAIN THE EXCLUSIVE INTELLECTUAL PROPERTY OF ARCHITECTURE DEMAREST, L.P. AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THIS SPECIFIED PROJECT ONLY. NONE OF SUCH
IDEAS, DESIGN, ARRANGEMENTS OR PLANS SHALL BE USED ON ANY OTHER PROJECT OR EXTENSIONS OF THIS PROJECT OR USED BY OR DISCLOSED TO ANY PERSON, FIRM OR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION FORM AND APPROPRIATE COMPENSATION TO ARCHITECTUREDEMAREST, L.P. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. THE CONTRACTOR
SHALL BEAR SOLE RESPONSIBILITY FOR VERIFYING ALL DIMENSIONS ON THIS PROJECT AND NOTIFIYING ARCHITECTURE DEMAREST, L.P. OF ANY DEVIATIONS. THE CONTRACTOR SHALL BEAR SOLE RESPONSIBILITY FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, CONFIRMING COORDINATION AND FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT. ARCHITECTURE DEMAREST, L.P.
WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT.
E122
GENERAL NOTES
BUILDING KEYPLAN
A.
B.
UP
UP
AREA A3
WP1
HP2:25
AREA A1
C.
D.
E.
AREA A2
UP
F.
CLUBHOUSE
ALL WORK SHALL BE IN COMPLIANCE WITH THE MOST CURRENT EDITION OF THE NATIONAL
ELECTRICAL CODE, STATE CODE(S) AND LOCAL CODE(S).
ELECTRICAL CONTRACTOR SHALL VISIT THE SITE TO FAMILIARIZE THEMSELVES WITH THE SCOPE
OF THE PROJECT PRIOR TO BID.
REFER TO ARCHITECTURAL DRAWINGS FOR WALL AND CEILING CONSTRUCTION TYPES.
ELECTRICAL DRAWINGS SHOULD NOT BE SCALED, REFER TO ARCHITECTURAL DRAWINGS AND
ADDITIONAL DETAILS CONTAINED HEREIN FOR DIMENSIONING AND SCALING.
ELECTRICAL WIRING, EQUIPMENT, APPARATUS, ETC. LOCATED ABOVE CEILINGS SHALL BE LISTED
FOR USE IN AIR HANDLING PLENUMS AND SHALL BE INSTALLED IN ACCORDANCE WITH NEC
300.22. THIS INCLUDES ALL LOW VOLTAGE CABLING AND EQUIPMENT.
LIGHT SWITCHES SHALL BE INSTALLED IN ACCESSIBLE LOCATIONS NO HIGHER THAN 42" AFF.
ALL SWITCHES IN APARTMENTS SHALL BE ROKER TYPE SWITCHES.
UP
WP/GFI
HP2:5
AREA B1
AREA B2
WP1
HP2:25
S1
HP2:2
F
X1
HP2:2
S1
HP2:2
Nacogdoches, TX
UP
LUMBERJACK LOFTS
SFA 1411 ASSOCIATES, L.P.
S1
HP2:2
WP/GFI
HP2:5
PERMIT SET
Electrical Plan Second Floor
Section A3
S1
HP2:2
S1
HP2:2
F
WP/GFI
HP2:5
S
TA
OF TE
TE
X
A
S
S1
HP2:2
TRENT E BEIGHLE
O
FE
EE
PR
R
100821
LIC
SS
E NS ED IN
G
IONA L EN
PE-SERVICES
F-10841
EXP: 11/30/12
S1
HP2:2
WP1
HP2:25
WP/GFI
HP2:5
ARCHITECTURE DEMAREST
S1
HP2:2
C ARCHITECTURE DEMAREST, L.P.
ALL RIGHTS RESERVED
DATE
F F
07/16/12
S2
HP2:2
S2
HP2:2
X1
HP2:2
1
Revision Schedule
No. Date
Description
Electrical Plan - Second Floor Section A3
1/8" = 1'-0"
JOB NO.
10051
SHEET NO.
COPYRIGHT (C) 2011 ARCHITECTURE DEMAREST, L.P. ALL IDEAS, DESIGNS, ARRANGEMENTS, PLANS, AND SPECIFICATIONS INDICATED OR REPRESENTED BY THIS DRAWING AS INSTRUMENTS OF SERVICE ARE AND SHALL REMAIN THE EXCLUSIVE INTELLECTUAL PROPERTY OF ARCHITECTURE DEMAREST, L.P. AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THIS SPECIFIED PROJECT ONLY. NONE OF SUCH
IDEAS, DESIGN, ARRANGEMENTS OR PLANS SHALL BE USED ON ANY OTHER PROJECT OR EXTENSIONS OF THIS PROJECT OR USED BY OR DISCLOSED TO ANY PERSON, FIRM OR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION FORM AND APPROPRIATE COMPENSATION TO ARCHITECTUREDEMAREST, L.P. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. THE CONTRACTOR
SHALL BEAR SOLE RESPONSIBILITY FOR VERIFYING ALL DIMENSIONS ON THIS PROJECT AND NOTIFIYING ARCHITECTURE DEMAREST, L.P. OF ANY DEVIATIONS. THE CONTRACTOR SHALL BEAR SOLE RESPONSIBILITY FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, CONFIRMING COORDINATION AND FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT. ARCHITECTURE DEMAREST, L.P.
WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT.
E123
GENERAL NOTES
BUILDING KEYPLAN
A.
B.
UP
C.
D.
UP
AREA A3
AREA A1
E.
AREA A2
UP
F.
CLUBHOUSE
ALL WORK SHALL BE IN COMPLIANCE WITH THE MOST CURRENT EDITION OF THE NATIONAL
ELECTRICAL CODE, STATE CODE(S) AND LOCAL CODE(S).
ELECTRICAL CONTRACTOR SHALL VISIT THE SITE TO FAMILIARIZE THEMSELVES WITH THE SCOPE
OF THE PROJECT PRIOR TO BID.
REFER TO ARCHITECTURAL DRAWINGS FOR WALL AND CEILING CONSTRUCTION TYPES.
ELECTRICAL DRAWINGS SHOULD NOT BE SCALED, REFER TO ARCHITECTURAL DRAWINGS AND
ADDITIONAL DETAILS CONTAINED HEREIN FOR DIMENSIONING AND SCALING.
ELECTRICAL WIRING, EQUIPMENT, APPARATUS, ETC. LOCATED ABOVE CEILINGS SHALL BE LISTED
FOR USE IN AIR HANDLING PLENUMS AND SHALL BE INSTALLED IN ACCORDANCE WITH NEC
300.22. THIS INCLUDES ALL LOW VOLTAGE CABLING AND EQUIPMENT.
LIGHT SWITCHES SHALL BE INSTALLED IN ACCESSIBLE LOCATIONS NO HIGHER THAN 42" AFF.
ALL SWITCHES IN APARTMENTS SHALL BE ROKER TYPE SWITCHES.
UP
AREA B1
Electrical Plan Second Floor
Section B1
HP3:5
WP/GFI
S1
HP3:2
S1
HP3:2
S1
HP3:2
EM1
HP3:2
S1
HP3:2
F
EM1
HP3:2
WP/GFI
HP3:5
S1
HP3:2
HP3:5
WP/GFI
S1
HP3:2
EM1
HP3:2
S1
HP3:2
F
S1
HP3:2
EM1
HP3:2
X1
HP3:2
S1
HP3:2
A
TRENT E BEIGHLE
100821
FE
O
EM1
HP3:2
S1
HP3:2
WP/GFI
HP3:5
S1
HP3:2
OF TE
TE
X
R
S1
HP3:2
EM1
HP3:2
PR
WP1
HP3:33
F
WP/GFI
EM1
HP3:5 HP3:2
X1
F
HP3:2
F
TA
S
S1
HP3:2
S
PERMIT SET
WP1
HP3:33
EE
UP
Nacogdoches, TX
LUMBERJACK LOFTS
SFA 1411 ASSOCIATES, L.P.
AREA B2
LIC
SS
E NS ED IN
G
IONA L EN
PE-SERVICES
F-10841
EXP: 11/30/12
S2
HP3:2
S2
HP3:2
ARCHITECTURE DEMAREST
C ARCHITECTURE DEMAREST, L.P.
ALL RIGHTS RESERVED
WP1
HP3:33
WP1
HP3:33
WP1
HP3:33
DATE
07/16/12
Revision Schedule
No. Date
Description
1
Electrical Plan - Second Floor Section B1
1/8" = 1'-0"
JOB NO.
10051
SHEET NO.
COPYRIGHT (C) 2011 ARCHITECTURE DEMAREST, L.P. ALL IDEAS, DESIGNS, ARRANGEMENTS, PLANS, AND SPECIFICATIONS INDICATED OR REPRESENTED BY THIS DRAWING AS INSTRUMENTS OF SERVICE ARE AND SHALL REMAIN THE EXCLUSIVE INTELLECTUAL PROPERTY OF ARCHITECTURE DEMAREST, L.P. AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THIS SPECIFIED PROJECT ONLY. NONE OF SUCH
IDEAS, DESIGN, ARRANGEMENTS OR PLANS SHALL BE USED ON ANY OTHER PROJECT OR EXTENSIONS OF THIS PROJECT OR USED BY OR DISCLOSED TO ANY PERSON, FIRM OR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION FORM AND APPROPRIATE COMPENSATION TO ARCHITECTUREDEMAREST, L.P. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. THE CONTRACTOR
SHALL BEAR SOLE RESPONSIBILITY FOR VERIFYING ALL DIMENSIONS ON THIS PROJECT AND NOTIFIYING ARCHITECTURE DEMAREST, L.P. OF ANY DEVIATIONS. THE CONTRACTOR SHALL BEAR SOLE RESPONSIBILITY FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, CONFIRMING COORDINATION AND FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT. ARCHITECTURE DEMAREST, L.P.
WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT.
E124
GENERAL NOTES
BUILDING KEYPLAN
A.
B.
UP
UP
AREA A3
AREA A1
X1
HP3:2
E.
AREA A2
UP
F.
CLUBHOUSE
F F
UP
S2
HP3:2
WP1
HP3:33
AREA B1
AREA B2
UP
S1
HP3:2
S1
HP3:2
HP3:5
WP/GFI
F
Nacogdoches, TX
S2
HP3:2
LUMBERJACK LOFTS
SFA 1411 ASSOCIATES, L.P.
S1
HP3:2
HP3:5
WP/GFI
C.
D.
ALL WORK SHALL BE IN COMPLIANCE WITH THE MOST CURRENT EDITION OF THE NATIONAL
ELECTRICAL CODE, STATE CODE(S) AND LOCAL CODE(S).
ELECTRICAL CONTRACTOR SHALL VISIT THE SITE TO FAMILIARIZE THEMSELVES WITH THE SCOPE
OF THE PROJECT PRIOR TO BID.
REFER TO ARCHITECTURAL DRAWINGS FOR WALL AND CEILING CONSTRUCTION TYPES.
ELECTRICAL DRAWINGS SHOULD NOT BE SCALED, REFER TO ARCHITECTURAL DRAWINGS AND
ADDITIONAL DETAILS CONTAINED HEREIN FOR DIMENSIONING AND SCALING.
ELECTRICAL WIRING, EQUIPMENT, APPARATUS, ETC. LOCATED ABOVE CEILINGS SHALL BE LISTED
FOR USE IN AIR HANDLING PLENUMS AND SHALL BE INSTALLED IN ACCORDANCE WITH NEC
300.22. THIS INCLUDES ALL LOW VOLTAGE CABLING AND EQUIPMENT.
LIGHT SWITCHES SHALL BE INSTALLED IN ACCESSIBLE LOCATIONS NO HIGHER THAN 42" AFF.
ALL SWITCHES IN APARTMENTS SHALL BE ROKER TYPE SWITCHES.
PERMIT SET
Electrical Plan Second Floor
Section B2
S1
HP3:2
WP/GFI
HP3:5
S1
HP3:2
OF TE
TE
X
A
TRENT E BEIGHLE
O
FE
EE
R
100821
PR
F
WP1
HP3:33
TA
S
S
S1
HP3:2
LIC
SS
E NS ED IN
G
IONA L EN
S1
HP3:2 HP3:5
WP/GFI
PE-SERVICES
F-10841
EXP: 11/30/12
S1
HP3:5 HP3:2
WP/GFI
ARCHITECTURE DEMAREST
C ARCHITECTURE DEMAREST, L.P.
ALL RIGHTS RESERVED
DATE
07/16/12
Revision Schedule
No. Date
Description
1
Electrical Plan - Second Floor Section B2
1/8" = 1'-0"
JOB NO.
10051
SHEET NO.
COPYRIGHT (C) 2011 ARCHITECTURE DEMAREST, L.P. ALL IDEAS, DESIGNS, ARRANGEMENTS, PLANS, AND SPECIFICATIONS INDICATED OR REPRESENTED BY THIS DRAWING AS INSTRUMENTS OF SERVICE ARE AND SHALL REMAIN THE EXCLUSIVE INTELLECTUAL PROPERTY OF ARCHITECTURE DEMAREST, L.P. AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THIS SPECIFIED PROJECT ONLY. NONE OF SUCH
IDEAS, DESIGN, ARRANGEMENTS OR PLANS SHALL BE USED ON ANY OTHER PROJECT OR EXTENSIONS OF THIS PROJECT OR USED BY OR DISCLOSED TO ANY PERSON, FIRM OR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION FORM AND APPROPRIATE COMPENSATION TO ARCHITECTUREDEMAREST, L.P. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. THE CONTRACTOR
SHALL BEAR SOLE RESPONSIBILITY FOR VERIFYING ALL DIMENSIONS ON THIS PROJECT AND NOTIFIYING ARCHITECTURE DEMAREST, L.P. OF ANY DEVIATIONS. THE CONTRACTOR SHALL BEAR SOLE RESPONSIBILITY FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, CONFIRMING COORDINATION AND FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT. ARCHITECTURE DEMAREST, L.P.
WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT.
E125
GENERAL NOTES
BUILDING KEYPLAN
A.
B.
UP
C.
D.
UP
AREA A3
AREA A1
E.
AREA A2
UP
F.
CLUBHOUSE
ALL WORK SHALL BE IN COMPLIANCE WITH THE MOST CURRENT EDITION OF THE NATIONAL
ELECTRICAL CODE, STATE CODE(S) AND LOCAL CODE(S).
ELECTRICAL CONTRACTOR SHALL VISIT THE SITE TO FAMILIARIZE THEMSELVES WITH THE SCOPE
OF THE PROJECT PRIOR TO BID.
REFER TO ARCHITECTURAL DRAWINGS FOR WALL AND CEILING CONSTRUCTION TYPES.
ELECTRICAL DRAWINGS SHOULD NOT BE SCALED, REFER TO ARCHITECTURAL DRAWINGS AND
ADDITIONAL DETAILS CONTAINED HEREIN FOR DIMENSIONING AND SCALING.
ELECTRICAL WIRING, EQUIPMENT, APPARATUS, ETC. LOCATED ABOVE CEILINGS SHALL BE LISTED
FOR USE IN AIR HANDLING PLENUMS AND SHALL BE INSTALLED IN ACCORDANCE WITH NEC
300.22. THIS INCLUDES ALL LOW VOLTAGE CABLING AND EQUIPMENT.
LIGHT SWITCHES SHALL BE INSTALLED IN ACCESSIBLE LOCATIONS NO HIGHER THAN 42" AFF.
ALL SWITCHES IN APARTMENTS SHALL BE ROKER TYPE SWITCHES.
UP
AREA B1
Electrical Plan Third Floor
Section A1
PERMIT SET
UP
Nacogdoches, TX
LUMBERJACK LOFTS
SFA 1411 ASSOCIATES, L.P.
AREA B2
S1
HP1:3
S1
HP1:3
S1
HP1:3
EM1
HP1:3
S1
HP1:3
HP1:6
WP/GFI
S1
HP1:3
F
F
WP/GFI
HP1:6
S1
HP1:3
S1
HP1:3
EM1
HP1:3
EM1
HP1:3
S1
HP1:3
S1
HP1:3
S1
HP1:3
HP1:6
WP/GFI
S1
HP1:3
F
EM1
HP1:3
TA
A
TRENT E BEIGHLE
100821
PR
FE
O
S2
HP1:3
OF TE
TE
X
R
X2
HP1:3
EM1
HP1:3
EM1
HP1:3
S
S1
HP1:3
WP/GFI
HP1:6
EE
F F
S
S1
HP1:3
LIC
SS
E NS ED IN
G
IONA L EN
PE-SERVICES
F-10841
EXP: 11/30/12
S2
HP1:3
ARCHITECTURE DEMAREST
C ARCHITECTURE DEMAREST, L.P.
ALL RIGHTS RESERVED
DATE
07/16/12
Revision Schedule
No. Date
Description
1
Electrical Plan - Third Floor Section A1
1/8" = 1'-0"
JOB NO.
10051
SHEET NO.
COPYRIGHT (C) 2011 ARCHITECTURE DEMAREST, L.P. ALL IDEAS, DESIGNS, ARRANGEMENTS, PLANS, AND SPECIFICATIONS INDICATED OR REPRESENTED BY THIS DRAWING AS INSTRUMENTS OF SERVICE ARE AND SHALL REMAIN THE EXCLUSIVE INTELLECTUAL PROPERTY OF ARCHITECTURE DEMAREST, L.P. AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THIS SPECIFIED PROJECT ONLY. NONE OF SUCH
IDEAS, DESIGN, ARRANGEMENTS OR PLANS SHALL BE USED ON ANY OTHER PROJECT OR EXTENSIONS OF THIS PROJECT OR USED BY OR DISCLOSED TO ANY PERSON, FIRM OR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION FORM AND APPROPRIATE COMPENSATION TO ARCHITECTUREDEMAREST, L.P. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. THE CONTRACTOR
SHALL BEAR SOLE RESPONSIBILITY FOR VERIFYING ALL DIMENSIONS ON THIS PROJECT AND NOTIFIYING ARCHITECTURE DEMAREST, L.P. OF ANY DEVIATIONS. THE CONTRACTOR SHALL BEAR SOLE RESPONSIBILITY FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, CONFIRMING COORDINATION AND FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT. ARCHITECTURE DEMAREST, L.P.
WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT.
E131
GENERAL NOTES
BUILDING KEYPLAN
A.
B.
UP
C.
D.
UP
AREA A3
AREA A1
E.
AREA A2
UP
F.
CLUBHOUSE
ALL WORK SHALL BE IN COMPLIANCE WITH THE MOST CURRENT EDITION OF THE NATIONAL
ELECTRICAL CODE, STATE CODE(S) AND LOCAL CODE(S).
ELECTRICAL CONTRACTOR SHALL VISIT THE SITE TO FAMILIARIZE THEMSELVES WITH THE SCOPE
OF THE PROJECT PRIOR TO BID.
REFER TO ARCHITECTURAL DRAWINGS FOR WALL AND CEILING CONSTRUCTION TYPES.
ELECTRICAL DRAWINGS SHOULD NOT BE SCALED, REFER TO ARCHITECTURAL DRAWINGS AND
ADDITIONAL DETAILS CONTAINED HEREIN FOR DIMENSIONING AND SCALING.
ELECTRICAL WIRING, EQUIPMENT, APPARATUS, ETC. LOCATED ABOVE CEILINGS SHALL BE LISTED
FOR USE IN AIR HANDLING PLENUMS AND SHALL BE INSTALLED IN ACCORDANCE WITH NEC
300.22. THIS INCLUDES ALL LOW VOLTAGE CABLING AND EQUIPMENT.
LIGHT SWITCHES SHALL BE INSTALLED IN ACCESSIBLE LOCATIONS NO HIGHER THAN 42" AFF.
ALL SWITCHES IN APARTMENTS SHALL BE ROKER TYPE SWITCHES.
UP
AREA B1
Electrical Plan Third Floor
Section A2
PERMIT SET
X1
HP1:3
S1
HP1:3
S1
HP1:3
EM1
HP1:3
S1
HP1:3
HP1:6
WP/GFI
F
S1
HP1:3
S1
HP1:3
EM1
HP1:3
X1
HP1:3
WP/GFI
HP2:6
X1
HP2:3
EM1
HP2:3
F
S1
HP2:3
EM1
HP2:3
S1
HP2:3
F
HP2:6
WP/GFI
S1
HP2:3
S1
HP2:3
S1
HP2:3
EM1
HP2:3
WP/GFI
HP2:6
S1
HP2:3
EM1
HP2:3
S1
HP2:3
X1
HP2:3
TA
OF TE
TE
X
100821
O
FE
S2
HP1:3
A
TRENT E BEIGHLE
F
PR
EM1
HP2:3
S1
HP2:3
F
S
EM1
HP1:3
R
S1
HP1:3
F
EM1
HP1:3
S
WP/GFI
HP1:6
EE
UP
Nacogdoches, TX
LUMBERJACK LOFTS
SFA 1411 ASSOCIATES, L.P.
AREA B2
LIC
SS
E NS ED IN
G
IONA L EN
PE-SERVICES
F-10841
EXP: 11/30/12
S1
HP1:3
S2
HP1:3
ARCHITECTURE DEMAREST
C ARCHITECTURE DEMAREST, L.P.
ALL RIGHTS RESERVED
DATE
07/16/12
Revision Schedule
No. Date
Description
1
Electrical Plan - Third Floor Section A2
1/8" = 1'-0"
JOB NO.
10051
SHEET NO.
COPYRIGHT (C) 2011 ARCHITECTURE DEMAREST, L.P. ALL IDEAS, DESIGNS, ARRANGEMENTS, PLANS, AND SPECIFICATIONS INDICATED OR REPRESENTED BY THIS DRAWING AS INSTRUMENTS OF SERVICE ARE AND SHALL REMAIN THE EXCLUSIVE INTELLECTUAL PROPERTY OF ARCHITECTURE DEMAREST, L.P. AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THIS SPECIFIED PROJECT ONLY. NONE OF SUCH
IDEAS, DESIGN, ARRANGEMENTS OR PLANS SHALL BE USED ON ANY OTHER PROJECT OR EXTENSIONS OF THIS PROJECT OR USED BY OR DISCLOSED TO ANY PERSON, FIRM OR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION FORM AND APPROPRIATE COMPENSATION TO ARCHITECTUREDEMAREST, L.P. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. THE CONTRACTOR
SHALL BEAR SOLE RESPONSIBILITY FOR VERIFYING ALL DIMENSIONS ON THIS PROJECT AND NOTIFIYING ARCHITECTURE DEMAREST, L.P. OF ANY DEVIATIONS. THE CONTRACTOR SHALL BEAR SOLE RESPONSIBILITY FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, CONFIRMING COORDINATION AND FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT. ARCHITECTURE DEMAREST, L.P.
WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT.
E132
GENERAL NOTES
BUILDING KEYPLAN
A.
B.
UP
UP
AREA A3
AREA A1
C.
D.
E.
AREA A2
UP
F.
CLUBHOUSE
ALL WORK SHALL BE IN COMPLIANCE WITH THE MOST CURRENT EDITION OF THE NATIONAL
ELECTRICAL CODE, STATE CODE(S) AND LOCAL CODE(S).
ELECTRICAL CONTRACTOR SHALL VISIT THE SITE TO FAMILIARIZE THEMSELVES WITH THE SCOPE
OF THE PROJECT PRIOR TO BID.
REFER TO ARCHITECTURAL DRAWINGS FOR WALL AND CEILING CONSTRUCTION TYPES.
ELECTRICAL DRAWINGS SHOULD NOT BE SCALED, REFER TO ARCHITECTURAL DRAWINGS AND
ADDITIONAL DETAILS CONTAINED HEREIN FOR DIMENSIONING AND SCALING.
ELECTRICAL WIRING, EQUIPMENT, APPARATUS, ETC. LOCATED ABOVE CEILINGS SHALL BE LISTED
FOR USE IN AIR HANDLING PLENUMS AND SHALL BE INSTALLED IN ACCORDANCE WITH NEC
300.22. THIS INCLUDES ALL LOW VOLTAGE CABLING AND EQUIPMENT.
LIGHT SWITCHES SHALL BE INSTALLED IN ACCESSIBLE LOCATIONS NO HIGHER THAN 42" AFF.
ALL SWITCHES IN APARTMENTS SHALL BE ROKER TYPE SWITCHES.
UP
AREA B1
WP/GFI
HP2:6
AREA B2
S1
HP2:3
F
X1
HP2:3
S1
HP2:3
EM1
HP2:3
Nacogdoches, TX
UP
EM1
HP2:3
LUMBERJACK LOFTS
SFA 1411 ASSOCIATES, L.P.
S1
HP2:3
WP/GFI
HP2:6
PERMIT SET
Electrical Plan Third Floor
Section A3
S1
HP2:3
EM1
HP2:3
S1
HP2:3
F
WP/GFI
HP2:6
S
EM1
HP2:3
TA
OF TE
TE
X
A
S
S1
HP2:3
TRENT E BEIGHLE
O
FE
EE
PR
R
100821
LIC
SS
E NS ED IN
G
IONA L EN
PE-SERVICES
F-10841
EXP: 11/30/12
S1
HP2:3
EM1
HP2:3
WP/GFI
HP2:6
ARCHITECTURE DEMAREST
S1
HP2:3
C ARCHITECTURE DEMAREST, L.P.
ALL RIGHTS RESERVED
DATE
07/16/12
F F
S2
HP2:3
S2
HP2:3
X1
HP2:3
1
Electrical Plan - Third Floor Section A3
1/8" = 1'-0"
Revision Schedule
No. Date
Description
JOB NO.
10051
SHEET NO.
COPYRIGHT (C) 2011 ARCHITECTURE DEMAREST, L.P. ALL IDEAS, DESIGNS, ARRANGEMENTS, PLANS, AND SPECIFICATIONS INDICATED OR REPRESENTED BY THIS DRAWING AS INSTRUMENTS OF SERVICE ARE AND SHALL REMAIN THE EXCLUSIVE INTELLECTUAL PROPERTY OF ARCHITECTURE DEMAREST, L.P. AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THIS SPECIFIED PROJECT ONLY. NONE OF SUCH
IDEAS, DESIGN, ARRANGEMENTS OR PLANS SHALL BE USED ON ANY OTHER PROJECT OR EXTENSIONS OF THIS PROJECT OR USED BY OR DISCLOSED TO ANY PERSON, FIRM OR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION FORM AND APPROPRIATE COMPENSATION TO ARCHITECTUREDEMAREST, L.P. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. THE CONTRACTOR
SHALL BEAR SOLE RESPONSIBILITY FOR VERIFYING ALL DIMENSIONS ON THIS PROJECT AND NOTIFIYING ARCHITECTURE DEMAREST, L.P. OF ANY DEVIATIONS. THE CONTRACTOR SHALL BEAR SOLE RESPONSIBILITY FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, CONFIRMING COORDINATION AND FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT. ARCHITECTURE DEMAREST, L.P.
WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT.
E133
GENERAL NOTES
BUILDING KEYPLAN
A.
B.
UP
C.
D.
UP
AREA A3
AREA A1
E.
AREA A2
UP
F.
CLUBHOUSE
ALL WORK SHALL BE IN COMPLIANCE WITH THE MOST CURRENT EDITION OF THE NATIONAL
ELECTRICAL CODE, STATE CODE(S) AND LOCAL CODE(S).
ELECTRICAL CONTRACTOR SHALL VISIT THE SITE TO FAMILIARIZE THEMSELVES WITH THE SCOPE
OF THE PROJECT PRIOR TO BID.
REFER TO ARCHITECTURAL DRAWINGS FOR WALL AND CEILING CONSTRUCTION TYPES.
ELECTRICAL DRAWINGS SHOULD NOT BE SCALED, REFER TO ARCHITECTURAL DRAWINGS AND
ADDITIONAL DETAILS CONTAINED HEREIN FOR DIMENSIONING AND SCALING.
ELECTRICAL WIRING, EQUIPMENT, APPARATUS, ETC. LOCATED ABOVE CEILINGS SHALL BE LISTED
FOR USE IN AIR HANDLING PLENUMS AND SHALL BE INSTALLED IN ACCORDANCE WITH NEC
300.22. THIS INCLUDES ALL LOW VOLTAGE CABLING AND EQUIPMENT.
LIGHT SWITCHES SHALL BE INSTALLED IN ACCESSIBLE LOCATIONS NO HIGHER THAN 42" AFF.
ALL SWITCHES IN APARTMENTS SHALL BE ROKER TYPE SWITCHES.
UP
AREA B1
HP3:6
WP/GFI
S1
HP3:3
S1
HP3:3
EM1
HP3:3
S1
HP3:3
S1
HP3:3
F
EM1
HP3:3
WP/GFI
HP3:6
S1
HP3:3
HP3:6
WP/GFI
S1
HP3:3
EM1
HP3:3
S1
HP3:3
F
S1
HP3:3
EM1
HP3:3
X1
HP3:3
S1
HP3:3
Electrical Plan Third Floor
Section B1
TRENT E BEIGHLE
100821
FE
O
EM1
HP3:3
S1
HP3:3
WP/GFI
HP3:6
S1
HP3:3
A
R
S1
HP3:3
EM1
HP3:3
OF TE
TE
X
EE
F
PR
WP/GFI
EM1
HP3:6 HP3:3
X1
F
HP3:3
F
TA
S
S1
HP3:3
S
PERMIT SET
UP
Nacogdoches, TX
LUMBERJACK LOFTS
SFA 1411 ASSOCIATES, L.P.
AREA B2
LIC
SS
E NS ED IN
G
IONA L EN
PE-SERVICES
F-10841
EXP: 11/30/12
S2
HP3:3
S2
HP3:3
ARCHITECTURE DEMAREST
C ARCHITECTURE DEMAREST, L.P.
ALL RIGHTS RESERVED
DATE
07/16/12
Revision Schedule
No. Date
Description
1
Electrical Plan - Third Floor Section B1
1/8" = 1'-0"
JOB NO.
10051
SHEET NO.
COPYRIGHT (C) 2011 ARCHITECTURE DEMAREST, L.P. ALL IDEAS, DESIGNS, ARRANGEMENTS, PLANS, AND SPECIFICATIONS INDICATED OR REPRESENTED BY THIS DRAWING AS INSTRUMENTS OF SERVICE ARE AND SHALL REMAIN THE EXCLUSIVE INTELLECTUAL PROPERTY OF ARCHITECTURE DEMAREST, L.P. AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THIS SPECIFIED PROJECT ONLY. NONE OF SUCH
IDEAS, DESIGN, ARRANGEMENTS OR PLANS SHALL BE USED ON ANY OTHER PROJECT OR EXTENSIONS OF THIS PROJECT OR USED BY OR DISCLOSED TO ANY PERSON, FIRM OR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION FORM AND APPROPRIATE COMPENSATION TO ARCHITECTUREDEMAREST, L.P. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. THE CONTRACTOR
SHALL BEAR SOLE RESPONSIBILITY FOR VERIFYING ALL DIMENSIONS ON THIS PROJECT AND NOTIFIYING ARCHITECTURE DEMAREST, L.P. OF ANY DEVIATIONS. THE CONTRACTOR SHALL BEAR SOLE RESPONSIBILITY FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, CONFIRMING COORDINATION AND FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT. ARCHITECTURE DEMAREST, L.P.
WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT.
E134
GENERAL NOTES
BUILDING KEYPLAN
A.
B.
UP
AREA A3
AREA A1
UP
F.
CLUBHOUSE
S1
HP3:3
HP3:6
WP/GFI
S2
HP3:3
S2
HP3:3
UP
AREA B1
AREA B2
UP
S1
HP3:3
EM1
HP3:3
S1
HP3:3
HP3:6
WP/GFI
F
Nacogdoches, TX
F F
EM1
HP3:3
E.
AREA A2
X1
HP3:3
C.
D.
LUMBERJACK LOFTS
SFA 1411 ASSOCIATES, L.P.
UP
ALL WORK SHALL BE IN COMPLIANCE WITH THE MOST CURRENT EDITION OF THE NATIONAL
ELECTRICAL CODE, STATE CODE(S) AND LOCAL CODE(S).
ELECTRICAL CONTRACTOR SHALL VISIT THE SITE TO FAMILIARIZE THEMSELVES WITH THE SCOPE
OF THE PROJECT PRIOR TO BID.
REFER TO ARCHITECTURAL DRAWINGS FOR WALL AND CEILING CONSTRUCTION TYPES.
ELECTRICAL DRAWINGS SHOULD NOT BE SCALED, REFER TO ARCHITECTURAL DRAWINGS AND
ADDITIONAL DETAILS CONTAINED HEREIN FOR DIMENSIONING AND SCALING.
ELECTRICAL WIRING, EQUIPMENT, APPARATUS, ETC. LOCATED ABOVE CEILINGS SHALL BE LISTED
FOR USE IN AIR HANDLING PLENUMS AND SHALL BE INSTALLED IN ACCORDANCE WITH NEC
300.22. THIS INCLUDES ALL LOW VOLTAGE CABLING AND EQUIPMENT.
LIGHT SWITCHES SHALL BE INSTALLED IN ACCESSIBLE LOCATIONS NO HIGHER THAN 42" AFF.
ALL SWITCHES IN APARTMENTS SHALL BE ROKER TYPE SWITCHES.
S1
HP3:3
PERMIT SET
Electrical Plan Third Floor
Section B2
EM1
HP3:3
WP/GFI
HP3:6
S1
HP3:3
EM1
HP3:3
A
O
EE
R
100821
FE
S1
HP3:3 HP3:6
WP/GFI
OF TE
TE
X
TRENT E BEIGHLE
PR
F
TA
S
S
S1
HP3:3
LIC
SS
E NS ED IN
G
IONA L EN
PE-SERVICES
F-10841
EXP: 11/30/12
EM1
HP3:3
S1
HP3:6 HP3:3
WP/GFI
ARCHITECTURE DEMAREST
C ARCHITECTURE DEMAREST, L.P.
ALL RIGHTS RESERVED
DATE
07/16/12
Revision Schedule
No. Date
Description
1
Electrical Plan - Third Floor Section B2
1/8" = 1'-0"
JOB NO.
10051
SHEET NO.
COPYRIGHT (C) 2011 ARCHITECTURE DEMAREST, L.P. ALL IDEAS, DESIGNS, ARRANGEMENTS, PLANS, AND SPECIFICATIONS INDICATED OR REPRESENTED BY THIS DRAWING AS INSTRUMENTS OF SERVICE ARE AND SHALL REMAIN THE EXCLUSIVE INTELLECTUAL PROPERTY OF ARCHITECTURE DEMAREST, L.P. AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THIS SPECIFIED PROJECT ONLY. NONE OF SUCH
IDEAS, DESIGN, ARRANGEMENTS OR PLANS SHALL BE USED ON ANY OTHER PROJECT OR EXTENSIONS OF THIS PROJECT OR USED BY OR DISCLOSED TO ANY PERSON, FIRM OR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION FORM AND APPROPRIATE COMPENSATION TO ARCHITECTUREDEMAREST, L.P. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. THE CONTRACTOR
SHALL BEAR SOLE RESPONSIBILITY FOR VERIFYING ALL DIMENSIONS ON THIS PROJECT AND NOTIFIYING ARCHITECTURE DEMAREST, L.P. OF ANY DEVIATIONS. THE CONTRACTOR SHALL BEAR SOLE RESPONSIBILITY FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, CONFIRMING COORDINATION AND FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT. ARCHITECTURE DEMAREST, L.P.
WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT.
E135
GENERAL NOTES
A.
ALL WORK SHALL BE IN COMPLIANCE WITH THE MOST CURRENT EDITION OF THE NATIONAL
ELECTRICAL CODE, STATE CODE(S) AND LOCAL CODE(S).
ELECTRICAL CONTRACTOR SHALL VISIT THE SITE TO FAMILIARIZE THEMSELVES WITH THE SCOPE
OF THE PROJECT PRIOR TO BID.
REFER TO ARCHITECTURAL DRAWINGS FOR WALL AND CEILING CONSTRUCTION TYPES.
ELECTRICAL DRAWINGS SHOULD NOT BE SCALED, REFER TO ARCHITECTURAL DRAWINGS AND
ADDITIONAL DETAILS CONTAINED HEREIN FOR DIMENSIONING AND SCALING.
ELECTRICAL WIRING, EQUIPMENT, APPARATUS, ETC. LOCATED ABOVE CEILINGS SHALL BE LISTED
FOR USE IN AIR HANDLING PLENUMS AND SHALL BE INSTALLED IN ACCORDANCE WITH NEC
300.22. THIS INCLUDES ALL LOW VOLTAGE CABLING AND EQUIPMENT.
LIGHT SWITCHES SHALL BE INSTALLED IN ACCESSIBLE LOCATIONS NO HIGHER THAN 42" AFF.
ALL SWITCHES IN APARTMENTS SHALL BE ROKER TYPE SWITCHES.
B.
PANEL
MB1
UH-2
MB1:7,9
C.
D.
BUILDING KEYPLAN
MB1:1
WP/GFI
E.
MB1:5
MB1:1
MB1:1
UP
UP
F.
AREA A3
AREA A1
MSSI-2
CH:14,16
AREA A2
UP
MB1:5
3
MB1:6
C
1
AREA B1
AREA B2
MB1:5
** ALL RECEPTACLES IN
MAINTENANCE BUILDING
SHALL BE GFI TYPE
PLAN NOTES
2
MB1:2
EF-3
MB1:11
PROVIDE POWER DEVICES AND ELECTRICAL CIRCUITRY AS SHOWN FOR TELEPHONE, DATA,
TELEVISION AND FIRE ALARM EQUIPMENT REQUIREMENTS. VERIFY EXACT LOCATIONS PRIOR
TO ROUGH-IN.
3
PROVIDE ELECTRICAL CONNECTION AND ELECTRICAL CIRCUITRY FOR MINI-SPLIT DEDICATED
SYSTEM. SEE ELECTRICAL PANEL SCHEDULES FOR CIRCUITRY SIZES.
MB1:4
MB1:4
MB1:4
3
MB1:2
Enlarged Clubhouse BCR/IDF
1/4" = 1'-0"
Electrical Power Plan - Maintenance Building
1/4" = 1'-0"
GFI
PQLA:5
GFI
PQLA:4
PQLA:2
EWH-3
PQLA:1,3
PQLA:2
CU-3
CU-3
CH:10,12 CH:6,8
CU-3
CH:2,4
CH:1
WP/GFI
PANEL "PQLA"
3
CH:15
CH:13
C
C
CH:11
FITNESS RM
CH:30
CENTER
C
CH:18
CH:1
WP/GFI
C
CH:18
EWH-3
CH:53,55
CH:19
CH:50
AHU-3 MAIL
CH:39,41
AHU-3
CH:35,37
GFI
CH:28
CH:1
WP/GFI
ROOM
Branch Panel: PQLA
Location: POOL EQUIP 234
Supply From:
Mounting: Surface
Enclosure:
CH:52
CH:50
CH:34
Volts: 120/240 Single
Phases: 1
Wires: 3
A.I.C. Rating:
Mains Type:
Mains Rating:
MCB Rating:
42000
MCB
150 A
150 A
Notes:
LEASING OFFICE
CORRIDOR
TA
OF TE
TE
X
A
S
CH:19
C
CH:50
CH:50
CH:51
CH:34
PANEL "CH"
EF-2
CH:28
CH:11
CH:50
CH:51
CH:34
CH:34
CH:31
CH:32
CH:11
AHU-3
CH:43,45
Pool Equipment Room and Restrooms
1/4" = 1'-0"
S
CH:15
JAN
C
C CH:17
CH:11
GFI
CH:13 C
C CH:28
CH:11 CH:3
GFI CH:28
CH:5
GFI
P.C.
CH:7
GFI
CH:9
4
ELEC/MDF
CH:29
C
UP
3
E211
MSS-2
CH:14,16
PQLA:2
PERMIT SET
2
MB1:3
MB1:3
2
PTAC-1
MB1:8,10
MB1:2
MB1:3
PROVIDE FIRE-RATED PLYWOOD EQUIPMENT BACKBOARD ON BACK AND SIDE WALL OF
ELECTRICAL CLOSET FOR THE MOUNTING OF TELEPHONE, DATA, TELEVISION, FIRE ALARM
AND ELECTRICAL DISTRIBUTION EQUIPMENT. PROVIDE (1) #3 COPPER GROUND WIRE FROM
MAIN GROUNDING ELECTRODE TO EQUIPMENT BACKBOARD. PROVIDE 12"X3"X1/4" COPPER
TERMINATION BAR FOR USE BY THE LOW VOLTAGE SYSTEMS INSTALLER(S).
UP
PANEL "CH"
MB1:5
1
Nacogdoches, TX
UP
LUMBERJACK LOFTS
SFA 1411 ASSOCIATES, L.P.
CH:33
CH:62
CH:63
CH:64
CH:65
CH:66
CH:67
CH:68
MB1:1
Electrical Power
Plan - Clubhouse
and Maintenance
Building
CLUBHOUSE
CH:47
TRENT E BEIGHLE
CH:20
IN-FLOOR
CH:19
CH:19
IN-FLOOR
CH:21 CH:22
CH:20
CH:23
CH:20
CH:50
MEN
CH:36
CH:20
CH:48
GFI
CH:25
GFI
CH:25
CH:27
GFI
CH:26
GFI
CH:26
GFI
GFI
CH:27
WOMEN
CH:49
CH:36
CH:36
CH:28
CH:27
GFI
GFI
CH:27
WORK RM
CH:36
CH:38
CH:42
GFI
ASST. MGR.
UP
CH:44
CH:40
CH:38
CH:46
CH:44
CH:42
GFI
CH:38
CH:46
CH:44
CH:46
CH:46
WP/GFI
CH:1
Trip
Water Heater
30 A
Drinking Fountain
Spare
Spare
Spare
Spare
Space
Space
Space
Space
Space
Space
Space
Space
Space
Space
Space
Space
20 A
20 A
20 A
20 A
20 A
-------------
Space
--
Space
-Total...
Total...
2250 VA
540 VA
2250 VA
180 VA
180 VA
266 VA
0 VA
0 VA
0 VA
0 VA
0 VA
0 VA
0 VA
0 VA
0 VA
0 VA
0 VA
0 VA
0 VA
0 VA
0 VA
0 VA
0 VA
0 VA
0 VA
0 VA
0 VA
0 VA
0 VA
0 VA
0 VA
0 VA
0 VA
0 VA
0 VA
0 VA
0 VA
0 VA
0 VA
0 VA
3236 VA
27 A
0 VA
0 VA
100821
Trip
20 A
20 A
20 A
-------------------
Circuit Description
Receptacles
Drinking Fountain
Lighting
Space
Space
Space
Space
Space
Space
Space
Space
Space
Space
Space
Space
Space
Space
Space
Space
Space
Space
0 VA
0A
Electrical Power Plan - Clubhouse
1/8" = 1'-0"
Load Classification
HVAC
Lighting
Lighting - Dwelling Unit
Receptacle
Connected Load
4500 VA
118 VA
148 VA
900 VA
Demand Factor
100.00%
125.00%
100.00%
100.00%
Estimated Demand
4500 VA
148 VA
148 VA
900 VA
FE
LIC
SS
E NS ED IN
G
IONA L EN
PE-SERVICES
F-10841
EXP: 11/30/12
ARCHITECTURE DEMAREST
C ARCHITECTURE DEMAREST, L.P.
ALL RIGHTS RESERVED
DATE
07/16/12
Revision Schedule
No. Date
Description
Legend:
1
CKT
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
R
Circuit Description
B
EE
CH:34
REF.
CH:24
REF.
CH:23
CKT
1
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39
41
A
O
COMMUNITY
SPACE
CH:49
B
PR
CH:28
CH:19
A
Panel Totals
Total Conn. Load:
Total Est. Demand:
Total Conn.:
Total Est. Demand:
5666 VA
5696 VA
24 A
24 A
JOB NO.
10051
SHEET NO.
COPYRIGHT (C) 2011 ARCHITECTURE DEMAREST, L.P. ALL IDEAS, DESIGNS, ARRANGEMENTS, PLANS, AND SPECIFICATIONS INDICATED OR REPRESENTED BY THIS DRAWING AS INSTRUMENTS OF SERVICE ARE AND SHALL REMAIN THE EXCLUSIVE INTELLECTUAL PROPERTY OF ARCHITECTURE DEMAREST, L.P. AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THIS SPECIFIED PROJECT ONLY. NONE OF SUCH
IDEAS, DESIGN, ARRANGEMENTS OR PLANS SHALL BE USED ON ANY OTHER PROJECT OR EXTENSIONS OF THIS PROJECT OR USED BY OR DISCLOSED TO ANY PERSON, FIRM OR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION FORM AND APPROPRIATE COMPENSATION TO ARCHITECTUREDEMAREST, L.P. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. THE CONTRACTOR
SHALL BEAR SOLE RESPONSIBILITY FOR VERIFYING ALL DIMENSIONS ON THIS PROJECT AND NOTIFIYING ARCHITECTURE DEMAREST, L.P. OF ANY DEVIATIONS. THE CONTRACTOR SHALL BEAR SOLE RESPONSIBILITY FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, CONFIRMING COORDINATION AND FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT. ARCHITECTURE DEMAREST, L.P.
WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT.
E211
ELECTRICAL LOAD CALCULATION FOR RESIDENCE UNIT TYPE A1, A1-ALT, A1-HC
ELECTRICAL LOAD CALCULATION FOR RESIDENCE UNIT TYPE B1, B1-ALT, B2, B2-ALT, B3
ELECTRICAL LOAD CALCULATION FOR RESIDENCE UNIT TYPE D1, D1-HC
METHOD FOR DETERMINING FEEDER LOAD NEC 220.82 SINGLE FAMILY DWELLING STANDARD CALCULATION
METHOD FOR DETERMINING FEEDER LOAD NEC 220.82 SINGLE FAMILY DWELLING STANDARD CALCULATION
METHOD FOR DETERMINING FEEDER LOAD NEC 220.82 SINGLE FAMILY DWELLING STANDARD CALCULATION
GENERAL LIGHTING LOAD
TOTAL OF GENERAL LIGHTING
220.42
3VA/SQFT X 1,355 SQFT (LARGEST UNIT SQFT USED)
4,065 VA
4,500 VA (KITCHEN AND LAUNDRY)
SMALL APPLIANCE LOAD
220.52(A)&(B)
4,500 VA (KITCHEN AND LAUNDRY)
220.53
220.53
220.53
4,500 VA (WATER HEATER)
750 VA (DISHWASHER)
750 VA (DISPOSAL)
APPLIANCE LOAD
220.53
220.53
220.53
4,500 VA (WATER HEATER)
750 VA (DISHWASHER)
750 VA (DISPOSAL)
ELECTRIC CLOTHES DRYER
220.54
5,000 VA
ELECTRIC CLOTHES DRYER
220.54
5,000 VA
8,000 VA
ELECTRIC RANGE
220.55
8,000 VA
ELECTRIC RANGE
220.55
8,000 VA
TOTAL OF GENERAL LOADS
25,075 VA
TOTAL OF GENERAL LOADS
26,230 VA
TOTAL OF GENERAL LOADS
27,565 VA
FIRST 10KVA AT 100%
10,000 VA
FIRST 10KVA AT 100%
10,000 VA
FIRST 10KVA AT 100%
10,000 VA
REMAINDER AT 40%
6,030 VA
REMAINDER AT 40%
6,492 VA
REMAINDER AT 40%
7,026 VA
TOTAL NET GENERAL LOAD
16,030 VA
TOTAL NET GENERAL LOAD
16,492 VA
TOTAL NET GENERAL LOAD
17,026 VA
HEAT PUMP
65% OF SUPPLEMENTAL HEAT
TOTAL HVAC LOAD
1,747 VA
3,250 VA
4,997 VA
HEAT PUMP
65% OF SUPPLEMENTAL HEAT
TOTAL HVAC LOAD
1,747 VA
3,250 VA
4,997 VA
HEAT PUMP
65% OF SUPPLEMENTAL HEAT
TOTAL HVAC LOAD
3,283
5,200 VA
8,483 VA
HEAT PUMP AND SUPPLEMENTAL HEAT
NET GENERAL LOAD
TOTAL LOAD
4,997 VA
16,030 VA
21,027 VA
HEAT PUMP AND SUPPLEMENTAL HEAT
NET GENERAL LOAD
TOTAL LOAD
4,997 VA
16,492 VA
21,489 VA
HEAT PUMP AND SUPPLEMENTAL HEAT
NET GENERAL LOAD
TOTAL LOAD
8,483 VA
17,026 VA
25,509 VA
4,500 VA (KITCHEN AND LAUNDRY)
SMALL APPLIANCE LOAD
220.52(A)&(B)
220.53
220.53
220.53
4,500 VA (WATER HEATER)
750 VA (DISHWASHER)
750 VA (DISPOSAL)
APPLIANCE LOAD
ELECTRIC CLOTHES DRYER
220.54
5,000 VA
ELECTRIC RANGE
220.55
TOTAL FEEDER LOAD 21,027 VA/240 VOLTS = 88 AMPS
100 AMP 120/240 VOLT SINGLE PHASE FEEDER REQUIRED
(LARGEST UNIT SQFT USED)
LIGHT FIXTURE SCHEDULE
2' SINGLE LAMP FLUORESCENT SURFACE MOUNT LIGHT FIXTURE
LITHONIA CA-1-17-AWR-120
4' SINGLE CIRCUIT TRACK WITH (4) GIMBAL RING TRACK HEADS,
50W GU-10 LAMPS, BRUSHED ALUMINUM FINISH
52" 5 BLADE CEILING FAN, WHITE FINISH, WHITE BLADES, 4-LAMP LIGHT KIT
DESIGN PARTNERS INTERNATIONAL #1059WH4RP2
7" ROUND, CLOSE TO CEILING LIGHT FIXTURE
DESIGN PARTNERS INTERNATIONAL #104210WH
(BATHROOM)
"RACETRAC" STRIP WITH (4) LAMPS, 24" LENGTH
DESIGN PARTNERS INTERNATIONAL #103010CH
EXTERIOR WALL LIGHT FIXTURE
DESIGN PARTNERS INTERNATIONAL #104262BK
(PATIO)
TOTAL FEEDER LOAD 25,509 VA/240 VOLTS = 106 AMPS
125 AMP 120/240 VOLT SINGLE PHASE FEEDER REQUIRED
TOTAL FEEDER LOAD 21,489 VA/240 VOLTS = 90 AMPS
100 AMP 120/240 VOLT SINGLE PHASE FEEDER REQUIRED
3
3
TYP
GENERAL NOTES
TV
7
A.
TV
12 TYP
B.
TYP 12
TYP
ALL WORK SHALL BE IN ACCORDANCE WITH THE 2005 EDITION OF THE NATIONAL
ELECTRICAL CODE, STATE CODE(S) AND LOCAL CODE(S).
ELECTRICAL CONTRACTOR SHALL VISIT THE SITE TO FAMILIARIZE THEMSELVES WITH
THE SCOPE OF THE PROJECT PRIOR TO BID.
ALL RECEPTACLES SERVING COUNTERTOP AREAS IN THE KITCHEN AND ALL
RECEPTACLES IN THE BATHROOM(S) SHALL BE GFI TYPE.
ALL RECEPTACLES LOCATED OUTSIDE SHALL BE GFI TYPE, SHALL BE LISTED AS
WEATHER-RESISTANT, AND SHALL HAVE WEATHERPROOF IN-USE COVERS.
IN LIVING AND SLEEPING ROOMS, ALL 15 AND 20 AMP, 120 VOLT RECEPTACLES
SHALL BE LISTED TAMPER-RESISTANT RECEPTACLES.
PROVIDE ARC FAULT CIRCUIT BREAKERS FOR CIRCUITS SERVING SLEEPING AREA
OUTLETS. LIVING ROOMS AND BEDROOMS ARE CONSIDERED SLEEPING AREAS.
ELECTRICAL CONTRACTOR SHALL PROVIDE SAFETY SWITCHES FOR ALL HVAC AND
PLUMBING EQUIPMENT IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE.
DEVICES INSTALLED IN FIRE SEPARATION WALLS/CEILINGS SHALL BE INSTALLED IN
ACCORDANCE WITH THE LISTING AND LABELING OF THE RATED ASSEMBLY. DO NOT
INSTALL OUTLET BOXES WITHIN THE SAME STUD SPACE.
SMOKE ALARMS SHALL BE CONNECTED TOGETHER SO THAT WHEN ONE SMOKE ALARM
WITHIN A RESIDENCE SOUNDS, ALL SMOKE ALARMS WITHIN THAT RESIDENCE SOUND.
PROVIDE VISUAL ALARM NOTIFICATION APPLIANCES AS PER THE REQUIREMENTS OF
SECTION 907.9.1.3 INTERNATIONAL BUILDING CODE (IBC) 2000.
VERIFY EXACT LOCATIONS OF BATHROOM EXHAUST FANS WITH MECHANICAL DRAWINGS.
DASHED CIRCUIT LINES REPRESENT SWITCH LEGS.
TYPE NM CABLE MAY BE USED FOR BRANCH WIRING WITHIN EACH DWELLING UNIT
ONLY (WHERE ALLOWABLE BY CODE).
ALL DEVICES AND COVERPLATES SHALL BE WHITE.
7
F
TYP 10
C.
F
F
D.
F
E.
F.
TV
SD
SD
6
TV
TYP
SD
F
2
H.
TV
3
EF
SD
3
17
10 TYP
G.
SD
17
EF
9
SD
GFI
K.
L.
M.
GFI
5
GFI
GFI
N.
GFI
4
16
15
16
LOADCENTER
PP
3
1
STRUCTURED
11
MEDIA PANEL
4
GFI
GFI
GFI
LOADCENTER
PP
3
Enlarged Unit A1 Electrical Plan
1/4" = 1'-0"
GFI
13
GFI
GFI
GFI
Enlarged Unit B1 Electrical Plan
1/4" = 1'-0"
2
4
PROVIDE DUPLEX RECEPTACLE IN CABINETRY ABOVE OVEN FOR MICROWAVE/HOOD COMBINATION.
VERIFY EXACT ROUGH-IN LOCATION WITH ARCHITECTURAL DRAWINGS.
5
PROVIDE DUPLEX RECEPTACLE LOCATED BELOW KITCHEN SINK FOR CONNECTION OF GARBAGE
DISPOSAL AND DISHWASHER. ELECTRICAL CONTRACTOR SHALL PROVIDE CORD KIT FOR
GARBAGE DISPOSAL AND DISHWASHER. THE TOP HALF OF THIS RECEPTACLE SHALL BE
CONTROLLED BY A WALL SWITCH LOCATED ADJACENT TO THE KITCHEN SINK FOR OPERATION OF
THE GARBAGE DISPOSAL. THE BOTTOM HALF OF THIS RECEPTACLE IS FOR DISHWASHER
CONNECTION. LABEL COVERPLATE SO THAT THE TOP HALF OF THE RECEPTACLE IS LABELED
FOR GARBAGE DISPOSAL CONNECTION. IN HANDICAPPED UNITS, DISPOSAL SHALL BE
HARDWIRED AND SWITCH SHALL BE MOUNTED WITHIN CABINET BELOW (SIDE OF CABINET).
TV
TV
6
PROVIDE 120 VOLT SMOKE ALARM WITH 9 VOLT BATTERY BACK-UP. SMOKE ALARMS SHALL BE
CONNECTED TOGETHER SO THAT WHEN ONE SMOKE ALARM WITHIN A RESIDENCE SOUNDS, ALL
SMOKE ALARMS WITHIN THAT RESIDENCE SOUND. SMOKE ALARMS IN ADAPTABLE UNITS SHALL
HAVE BUILT-IN STROBES. SMOKE ALARMS SHALL BE NO LESS THAN 36" FROM A BATHROOM
DOOR, SUPPLY AIR REGISTER, AND TIP OF A CEILING FAN BLADE.
7
SEE SYMBOL LEGEND FOR FACEPLATE AND CABLING REQUIREMENTS ASSOCIATED WITH
TELEPHONE, DATA, AND CABLE TELEVISION OUTLETS. DATA, TELEPHONE, AND CABLE TELEVISION
OUTLETS SHALL HOMERUN TO STRUCTURED MEDIA PANEL.
8
LIGHT FIXTURES INSTALLED IN CLOSETS SHALL CONFORM TO NEC ARTICLE 410.8.
9
PROVIDE DUPLEX RECEPTACLE LOCATED ON THE BACK OF PENINSULA BELOW COUNTERTOP
WITHIN 12" OF THE TOP EDGE OF THE COUNTERTOP.
10
FIRE ALARM SYSTEM DEVICE, SEE LOW VOLTAGE SHEETS FOR ADDITIONAL INFORMATION. ALL
HANDICAPPED UNITS SHALL INCLUDE HORN/STROBE DEVICES IN EVERY ROOM, INCLUDING
BATHROOM.
TV
TV
TV
SD
F
12 TYP
TYP
F
10
TV
F
3
TYP
F
F
16
8
SD
SD
6
SD
TYP
SD
8
15
TV
14
8
F
TYP
LOADCENTER
13 PP
11
EF
10 TYP
9
7
F
17
3
GFI
EF
GFI
SD
SD
SD
EF
SD
3
3
GFI
GFI
GFI
5
GFI
GFI
3
17
3
SD
GFI
3
4
GFI
Enlarged Unit B2 Electrical Plan
1/4" = 1'-0"
STRUCTURED
MEDIA PANEL
11
GFI
2
STRUCTURED
MEDIA PANEL
4
11
16
14
15
13
4
3
1
3
GFI
13
CONTRACTOR TO INSTALL LOAD CENTER PANEL FLUSH MOUNTED, MAINTAIN FIRE RATING OF WALL
WHERE APPLICABLE.
14
PROVIDE DUPLEX RECEPTACLE FOR WASHING MACHINE.
ARCHITECTURAL DRAWINGS.
15
PROVIDE 30 AMP, 120/240 VOLT NEMA 14-30R DRYER RECEPTACLE. THIS CIRCUIT MUST BE
PROVIDED WITH A GROUNDED (NEUTRAL) CONDUCTOR AND AN EQUIPMENT GROUNDING
CONDUCTOR. COORDINATE MOUNTING HEIGHT WITH ARCHITECTURAL DRAWINGS.
16
PROVIDE ELECTRICAL CONNECTION OR ELECTRIC WATER HEATER. ELECTRICAL CIRCUITRY SHALL
BE 30 AMPS, 240 VOLTS. UNIT D1 HAS A WATER HEATER CLOSET, REMAINING UNITS HAVE THE
WATER HEATER ON A SHELF ABOVE LAUNDRY MACHINE.
17
ELECTRICAL CIRCUITRY SHALL BE AS DESIGNATED IN THE ELECTRICAL LOADCENTER SCHEDULE
ON THIS SHEET.
8
8
GFI
PROVIDE CEILING FAN RATED JUNCTION BOX.
SD
EF
5
12
EF
3
LOADCENTER
PP
GFI
1
8
GFI
PROVIDE STRUCTURED MEDIA PANEL (SEE PROJECT SPECIFICATIONS). PROVIDE (1) 2" EMT
CONDUIT FROM PANEL TO ACCESSIBLE CORRIDOR CEILING AREA FOR CABLING. SEE LOW
VOLTAGE RISER FOR CABLING REQUIREMENTS. STRUCTURE MEDIA PANEL REQUIRES (1) 20 AMP
120 VOLT ELECTRICAL CIRCUIT.
2
TA
OF TE
TE
X
A
TRENT E BEIGHLE
100821
FE
O
PROVIDE ELECTRICAL CONNECTION AND SAFETY SWITCH FOR HEAT PUMP. ELECTRICAL
CIRCUITRY SHALL BE AS INDICATED IN THE LOADCENTER SCHEDULE. SEE OVERALL BUILDING
ELECTRICAL PLANS FOR EXACT LOCATIONS (HEAT PUMPS SHOWN ON THESE DRAWINGS ARE NOT
THE ACTUAL LOCATIONS).
PR
GFI
6
3
TV
7
SD
PROVIDE ELECTRICAL CONNECTION FOR ELECTRIC FURNACE. ELECTRICAL CIRCUITRY SHALL BE
AS INDICATED IN THE LOADCENTER SCHEDULE. FURNACE WILL BE PROVIDED WITH A
DISCONNECT SWITCH.
WP/GFI
TYP
F
2
S
EF
8
PROVIDE ELECTRICAL CIRCUIT AND 50 AMP 120/240 VOLT RANGE RECEPTACLE. THIS CIRCUIT
MUST BE PROVIDED WITH A GROUNDED (NEUTRAL) CONDUCTOR AND AN EQUIPMENT GROUNDING
CONDUCTOR. COORDINATE MOUNTING HEIGHT WITH ARCHITECTURAL DRAWINGS.
8
3
12 TYP
1
8
13
11
PLAN NOTES
1
5
R1
R1
STRUCTURED
MEDIA PANEL
GFI
15
14
8
I.
J.
2
14
GFI
1
6
TYP
EF
Nacogdoches, TX
3VA/SQFT X 910 SQFT
2,730 VA
R
APPLIANCE LOAD
220.42
EE
220.52(A)&(B)
GENERAL LIGHTING LOAD
TOTAL OF GENERAL LIGHTING
LUMBERJACK LOFTS
SFA 1411 ASSOCIATES, L.P.
SMALL APPLIANCE LOAD
(LARGEST UNIT SQFT USED)
Electrical Typical Room
Plans
3VA/SQFT X 525 SQFT
1,575 VA
S
220.42
PERMIT SET
GENERAL LIGHTING LOAD
TOTAL OF GENERAL LIGHTING
LIC
SS
E NS ED IN
G
IONA L EN
PE-SERVICES
F-10841
EXP: 11/30/12
ARCHITECTURE DEMAREST
C ARCHITECTURE DEMAREST, L.P.
ALL RIGHTS RESERVED
DATE
07/16/12
SECURE JUNCTION BOX TO STRUCTURE.
Revision Schedule
No. Date
Description
VERIFY ROUGH-IN LOCATIONS WITH
Enlarged Unit D1 Electrical Plan
1/4" = 1'-0"
COPYRIGHT (C) 2011 ARCHITECTURE DEMAREST, L.P. ALL IDEAS, DESIGNS, ARRANGEMENTS, PLANS, AND SPECIFICATIONS INDICATED OR REPRESENTED BY THIS DRAWING AS INSTRUMENTS OF SERVICE ARE AND SHALL REMAIN THE EXCLUSIVE INTELLECTUAL PROPERTY OF ARCHITECTURE DEMAREST, L.P. AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THIS SPECIFIED PROJECT ONLY. NONE OF SUCH
IDEAS, DESIGN, ARRANGEMENTS OR PLANS SHALL BE USED ON ANY OTHER PROJECT OR EXTENSIONS OF THIS PROJECT OR USED BY OR DISCLOSED TO ANY PERSON, FIRM OR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION FORM AND APPROPRIATE COMPENSATION TO ARCHITECTUREDEMAREST, L.P. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. THE CONTRACTOR
SHALL BEAR SOLE RESPONSIBILITY FOR VERIFYING ALL DIMENSIONS ON THIS PROJECT AND NOTIFIYING ARCHITECTURE DEMAREST, L.P. OF ANY DEVIATIONS. THE CONTRACTOR SHALL BEAR SOLE RESPONSIBILITY FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, CONFIRMING COORDINATION AND FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT. ARCHITECTURE DEMAREST, L.P.
WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT.
JOB NO.
10051
SHEET NO.
E301
LIGHT FIXTURE SCHEDULE
2' SINGLE LAMP FLUORESCENT SURFACE MOUNT LIGHT FIXTURE
LITHONIA CA-1-17-AWR-120
4' SINGLE CIRCUIT TRACK WITH (4) GIMBAL RING TRACK HEADS,
50W GU-10 LAMPS, BRUSHED ALUMINUM FINISH
52" 5 BLADE CEILING FAN, WHITE FINISH, WHITE BLADES, 4-LAMP LIGHT KIT
DESIGN PARTNERS INTERNATIONAL #1059WH4RP2
7" ROUND, CLOSE TO CEILING LIGHT FIXTURE
DESIGN PARTNERS INTERNATIONAL #104210WH
7 TYP
TV
GFI
GENERAL NOTES
TV
A.
TYP
F
8
TYP
F
SD
12 TYP
10
B.
F
F
10
17
ALL WORK SHALL BE IN ACCORDANCE WITH THE 2005 EDITION OF THE NATIONAL
ELECTRICAL CODE, STATE CODE(S) AND LOCAL CODE(S).
ELECTRICAL CONTRACTOR SHALL VISIT THE SITE TO FAMILIARIZE THEMSELVES WITH
THE SCOPE OF THE PROJECT PRIOR TO BID.
ALL RECEPTACLES SERVING COUNTERTOP AREAS IN THE KITCHEN AND ALL
RECEPTACLES IN THE BATHROOM(S) SHALL BE GFI TYPE.
ALL RECEPTACLES LOCATED OUTSIDE SHALL BE GFI TYPE, SHALL BE LISTED AS
WEATHER-RESISTANT, AND SHALL HAVE WEATHERPROOF IN-USE COVERS.
IN LIVING AND SLEEPING ROOMS, ALL 15 AND 20 AMP, 120 VOLT RECEPTACLES
SHALL BE LISTED TAMPER-RESISTANT RECEPTACLES.
PROVIDE ARC FAULT CIRCUIT BREAKERS FOR CIRCUITS SERVING SLEEPING AREA
OUTLETS. LIVING ROOMS AND BEDROOMS ARE CONSIDERED SLEEPING AREAS.
ELECTRICAL CONTRACTOR SHALL PROVIDE SAFETY SWITCHES FOR ALL HVAC AND
PLUMBING EQUIPMENT IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE.
DEVICES INSTALLED IN FIRE SEPARATION WALLS/CEILINGS SHALL BE INSTALLED IN
ACCORDANCE WITH THE LISTING AND LABELING OF THE RATED ASSEMBLY. DO NOT
INSTALL OUTLET BOXES WITHIN THE SAME STUD SPACE.
SMOKE ALARMS SHALL BE CONNECTED TOGETHER SO THAT WHEN ONE SMOKE ALARM
WITHIN A RESIDENCE SOUNDS, ALL SMOKE ALARMS WITHIN THAT RESIDENCE SOUND.
PROVIDE VISUAL ALARM NOTIFICATION APPLIANCES AS PER THE REQUIREMENTS OF
SECTION 907.9.1.3 INTERNATIONAL BUILDING CODE (IBC) 2000.
VERIFY EXACT LOCATIONS OF BATHROOM EXHAUST FANS WITH MECHANICAL DRAWINGS.
DASHED CIRCUIT LINES REPRESENT SWITCH LEGS.
TYPE NM CABLE MAY BE USED FOR BRANCH WIRING WITHIN EACH DWELLING UNIT
ONLY (WHERE ALLOWABLE BY CODE).
ALL DEVICES AND COVERPLATES SHALL BE WHITE.
C.
F
D.
3
E.
TV
SD
16
15
6 TYP
LOADCENTER
PP
13
TV
17
TV
EF
7 TYP
H.
SD
9
I.
SD
2
F
3
F.
6 TYP
G.
TV
8
14
SD
3
SD
GFI
J.
GFI
K.
L.
M.
5
GFI
9
SD
GFI
14
GFI
SD
GFI
1
4
1
STRUCTURED
MEDIA PANEL
3
GFI
8
13
GFI
GFI
LOADCENTER
PP
GFI
GFI
Enlarged Unit B2 Alt Electrical Plan
4
1/4" = 1'-0"
PLAN NOTES
8
GFI
8
8
GFI
EF
16
EF
GFI
N.
15
4
5
GFI
3
PROVIDE ELECTRICAL CONNECTION FOR ELECTRIC FURNACE. ELECTRICAL CIRCUITRY SHALL BE
AS INDICATED IN THE LOADCENTER SCHEDULE. FURNACE WILL BE PROVIDED WITH A
DISCONNECT SWITCH.
Enlarged Unit B1-HC Electrical Plan
3
1/4" = 1'-0"
3
PROVIDE ELECTRICAL CONNECTION AND SAFETY SWITCH FOR HEAT PUMP. ELECTRICAL
CIRCUITRY SHALL BE AS INDICATED IN THE LOADCENTER SCHEDULE. SEE OVERALL BUILDING
ELECTRICAL PLANS FOR EXACT LOCATIONS (HEAT PUMPS SHOWN ON THESE DRAWINGS ARE NOT
THE ACTUAL LOCATIONS).
4
PROVIDE DUPLEX RECEPTACLE IN CABINETRY ABOVE OVEN FOR MICROWAVE/HOOD COMBINATION.
VERIFY EXACT ROUGH-IN LOCATION WITH ARCHITECTURAL DRAWINGS.
5
PROVIDE DUPLEX RECEPTACLE LOCATED BELOW KITCHEN SINK FOR CONNECTION OF GARBAGE
DISPOSAL AND DISHWASHER. ELECTRICAL CONTRACTOR SHALL PROVIDE CORD KIT FOR
GARBAGE DISPOSAL AND DISHWASHER. THE TOP HALF OF THIS RECEPTACLE SHALL BE
CONTROLLED BY A WALL SWITCH LOCATED ADJACENT TO THE KITCHEN SINK FOR OPERATION OF
THE GARBAGE DISPOSAL. THE BOTTOM HALF OF THIS RECEPTACLE IS FOR DISHWASHER
CONNECTION. LABEL COVERPLATE SO THAT THE TOP HALF OF THE RECEPTACLE IS LABELED
FOR GARBAGE DISPOSAL CONNECTION. IN HANDICAPPED UNITS, DISPOSAL SHALL BE
HARDWIRED AND SWITCH SHALL BE MOUNTED WITHIN CABINET BELOW (SIDE OF CABINET).
3
3
TYP
7
TV
TV
TV
6
PROVIDE 120 VOLT SMOKE ALARM WITH 9 VOLT BATTERY BACK-UP. SMOKE ALARMS SHALL BE
CONNECTED TOGETHER SO THAT WHEN ONE SMOKE ALARM WITHIN A RESIDENCE SOUNDS, ALL
SMOKE ALARMS WITHIN THAT RESIDENCE SOUND. SMOKE ALARMS IN ADAPTABLE UNITS SHALL
HAVE BUILT-IN STROBES. SMOKE ALARMS SHALL BE NO LESS THAN 36" FROM A BATHROOM
DOOR, SUPPLY AIR REGISTER, AND TIP OF A CEILING FAN BLADE.
7
SEE SYMBOL LEGEND FOR FACEPLATE AND CABLING REQUIREMENTS ASSOCIATED WITH
TELEPHONE, DATA, AND CABLE TELEVISION OUTLETS. DATA, TELEPHONE, AND CABLE TELEVISION
OUTLETS SHALL HOMERUN TO STRUCTURED MEDIA PANEL.
8
LIGHT FIXTURES INSTALLED IN CLOSETS SHALL CONFORM TO NEC ARTICLE 410.8.
9
PROVIDE DUPLEX RECEPTACLE LOCATED ON THE BACK OF PENINSULA BELOW COUNTERTOP
WITHIN 12" OF THE TOP EDGE OF THE COUNTERTOP.
10
FIRE ALARM SYSTEM DEVICE, SEE LOW VOLTAGE SHEETS FOR ADDITIONAL INFORMATION. ALL
HANDICAPPED UNITS SHALL INCLUDE HORN/STROBE DEVICES IN EVERY ROOM, INCLUDING
BATHROOM.
TYP
TV
12 TYP
F
7
12 TYP
TV
F
F
SD
TV
SD
SD
SD
6
F
TYP
8
TV
F
EF
10 TYP
F
17
GFI
5
14
15
2
11
GFI
Enlarged Unit A1-HC Electrical Plan
1/4" = 1'-0"
3
1
4
SD
10 TYP
9
11
5
GFI
GFI
3
17
3
3
SD
GFI
LOADCENTER 13
PP
16
TYP
GFI
3
3
GFI
F
6
GFI
SD
STRUCTURED
MEDIA PANEL
SD
3
2
8
SD
GFI
SD
8
11
GFI
STRUCTURED
MEDIA PANEL
GFI
1
16
13
14
Enlarged Unit D1-HC Electrical Plan
1/4" = 1'-0"
15
LOADCENTER
PP
3
GFI
4
12
PROVIDE CEILING FAN RATED JUNCTION BOX.
13
CONTRACTOR TO INSTALL LOAD CENTER PANEL FLUSH MOUNTED, MAINTAIN FIRE RATING OF WALL
WHERE APPLICABLE.
14
PROVIDE DUPLEX RECEPTACLE FOR WASHING MACHINE.
ARCHITECTURAL DRAWINGS.
15
PROVIDE 30 AMP, 120/240 VOLT NEMA 14-30R DRYER RECEPTACLE. THIS CIRCUIT MUST BE
PROVIDED WITH A GROUNDED (NEUTRAL) CONDUCTOR AND AN EQUIPMENT GROUNDING
CONDUCTOR. COORDINATE MOUNTING HEIGHT WITH ARCHITECTURAL DRAWINGS.
16
PROVIDE ELECTRICAL CONNECTION OR ELECTRIC WATER HEATER. ELECTRICAL CIRCUITRY SHALL
BE 30 AMPS, 240 VOLTS. UNIT D1 HAS A WATER HEATER CLOSET, REMAINING UNITS HAVE THE
WATER HEATER ON A SHELF ABOVE LAUNDRY MACHINE.
17
ELECTRICAL CIRCUITRY SHALL BE AS DESIGNATED IN THE ELECTRICAL LOADCENTER SCHEDULE
ON THIS SHEET.
8
1
2
GFI
PROVIDE STRUCTURED MEDIA PANEL (SEE PROJECT SPECIFICATIONS). PROVIDE (1) 2" EMT
CONDUIT FROM PANEL TO ACCESSIBLE CORRIDOR CEILING AREA FOR CABLING. SEE LOW
VOLTAGE RISER FOR CABLING REQUIREMENTS. STRUCTURE MEDIA PANEL REQUIRES (1) 20 AMP
120 VOLT ELECTRICAL CIRCUIT.
TA
OF TE
TE
X
A
S
2
STRUCTURED
MEDIA PANEL
TRENT E BEIGHLE
100821
FE
O
PROVIDE ELECTRICAL CIRCUIT AND 50 AMP 120/240 VOLT RANGE RECEPTACLE. THIS CIRCUIT
MUST BE PROVIDED WITH A GROUNDED (NEUTRAL) CONDUCTOR AND AN EQUIPMENT GROUNDING
CONDUCTOR. COORDINATE MOUNTING HEIGHT WITH ARCHITECTURAL DRAWINGS.
PR
1
Nacogdoches, TX
WP/GFI
R
2
EE
12 TYP
Electrical Typical Room
Plans
3
EF
S
EXTERIOR WALL LIGHT FIXTURE
DESIGN PARTNERS INTERNATIONAL #104262BK
(PATIO)
LUMBERJACK LOFTS
SFA 1411 ASSOCIATES, L.P.
"RACETRAC" STRIP WITH (4) LAMPS, 24" LENGTH
DESIGN PARTNERS INTERNATIONAL #103010CH
PERMIT SET
(BATHROOM)
LIC
SS
E NS ED IN
G
IONA L EN
PE-SERVICES
F-10841
EXP: 11/30/12
ARCHITECTURE DEMAREST
C ARCHITECTURE DEMAREST, L.P.
ALL RIGHTS RESERVED
DATE
07/16/12
SECURE JUNCTION BOX TO STRUCTURE.
Revision Schedule
No. Date
Description
VERIFY ROUGH-IN LOCATIONS WITH
JOB NO.
10051
SHEET NO.
COPYRIGHT (C) 2011 ARCHITECTURE DEMAREST, L.P. ALL IDEAS, DESIGNS, ARRANGEMENTS, PLANS, AND SPECIFICATIONS INDICATED OR REPRESENTED BY THIS DRAWING AS INSTRUMENTS OF SERVICE ARE AND SHALL REMAIN THE EXCLUSIVE INTELLECTUAL PROPERTY OF ARCHITECTURE DEMAREST, L.P. AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THIS SPECIFIED PROJECT ONLY. NONE OF SUCH
IDEAS, DESIGN, ARRANGEMENTS OR PLANS SHALL BE USED ON ANY OTHER PROJECT OR EXTENSIONS OF THIS PROJECT OR USED BY OR DISCLOSED TO ANY PERSON, FIRM OR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION FORM AND APPROPRIATE COMPENSATION TO ARCHITECTUREDEMAREST, L.P. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. THE CONTRACTOR
SHALL BEAR SOLE RESPONSIBILITY FOR VERIFYING ALL DIMENSIONS ON THIS PROJECT AND NOTIFIYING ARCHITECTURE DEMAREST, L.P. OF ANY DEVIATIONS. THE CONTRACTOR SHALL BEAR SOLE RESPONSIBILITY FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, CONFIRMING COORDINATION AND FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT. ARCHITECTURE DEMAREST, L.P.
WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT.
E302
LIGHT FIXTURE SCHEDULE
2' SINGLE LAMP FLUORESCENT SURFACE MOUNT LIGHT FIXTURE
LITHONIA CA-1-17-AWR-120
4' SINGLE CIRCUIT TRACK WITH (4) GIMBAL RING TRACK HEADS,
50W GU-10 LAMPS, BRUSHED ALUMINUM FINISH
52" 5 BLADE CEILING FAN, WHITE FINISH, WHITE BLADES, 4-LAMP LIGHT KIT
DESIGN PARTNERS INTERNATIONAL #1059WH4RP2
7" ROUND, CLOSE TO CEILING LIGHT FIXTURE
DESIGN PARTNERS INTERNATIONAL #104210WH
C.
D.
E.
F.
G.
H.
I.
J.
K.
L.
M.
N.
PLAN NOTES
PROVIDE ELECTRICAL CONNECTION FOR ELECTRIC FURNACE. ELECTRICAL CIRCUITRY SHALL BE
AS INDICATED IN THE LOADCENTER SCHEDULE. FURNACE WILL BE PROVIDED WITH A
DISCONNECT SWITCH.
3
PROVIDE ELECTRICAL CONNECTION AND SAFETY SWITCH FOR HEAT PUMP. ELECTRICAL
CIRCUITRY SHALL BE AS INDICATED IN THE LOADCENTER SCHEDULE. SEE OVERALL BUILDING
ELECTRICAL PLANS FOR EXACT LOCATIONS (HEAT PUMPS SHOWN ON THESE DRAWINGS ARE NOT
THE ACTUAL LOCATIONS).
4
PROVIDE DUPLEX RECEPTACLE IN CABINETRY ABOVE OVEN FOR MICROWAVE/HOOD COMBINATION.
VERIFY EXACT ROUGH-IN LOCATION WITH ARCHITECTURAL DRAWINGS.
5
PROVIDE DUPLEX RECEPTACLE LOCATED BELOW KITCHEN SINK FOR CONNECTION OF GARBAGE
DISPOSAL AND DISHWASHER. ELECTRICAL CONTRACTOR SHALL PROVIDE CORD KIT FOR
GARBAGE DISPOSAL AND DISHWASHER. THE TOP HALF OF THIS RECEPTACLE SHALL BE
CONTROLLED BY A WALL SWITCH LOCATED ADJACENT TO THE KITCHEN SINK FOR OPERATION OF
THE GARBAGE DISPOSAL. THE BOTTOM HALF OF THIS RECEPTACLE IS FOR DISHWASHER
CONNECTION. LABEL COVERPLATE SO THAT THE TOP HALF OF THE RECEPTACLE IS LABELED
FOR GARBAGE DISPOSAL CONNECTION. IN HANDICAPPED UNITS, DISPOSAL SHALL BE
HARDWIRED AND SWITCH SHALL BE MOUNTED WITHIN CABINET BELOW (SIDE OF CABINET).
3
7
10 TYP
F
TV
7 TYP
10
12
F
OPEN TO BELOW
6
PROVIDE 120 VOLT SMOKE ALARM WITH 9 VOLT BATTERY BACK-UP. SMOKE ALARMS SHALL BE
CONNECTED TOGETHER SO THAT WHEN ONE SMOKE ALARM WITHIN A RESIDENCE SOUNDS, ALL
SMOKE ALARMS WITHIN THAT RESIDENCE SOUND. SMOKE ALARMS IN ADAPTABLE UNITS SHALL
HAVE BUILT-IN STROBES. SMOKE ALARMS SHALL BE NO LESS THAN 36" FROM A BATHROOM
DOOR, SUPPLY AIR REGISTER, AND TIP OF A CEILING FAN BLADE.
7
SEE SYMBOL LEGEND FOR FACEPLATE AND CABLING REQUIREMENTS ASSOCIATED WITH
TELEPHONE, DATA, AND CABLE TELEVISION OUTLETS. DATA, TELEPHONE, AND CABLE TELEVISION
OUTLETS SHALL HOMERUN TO STRUCTURED MEDIA PANEL.
8
LIGHT FIXTURES INSTALLED IN CLOSETS SHALL CONFORM TO NEC ARTICLE 410.8.
9
PROVIDE DUPLEX RECEPTACLE LOCATED ON THE BACK OF PENINSULA BELOW COUNTERTOP
WITHIN 12" OF THE TOP EDGE OF THE COUNTERTOP.
10
FIRE ALARM SYSTEM DEVICE, SEE LOW VOLTAGE SHEETS FOR ADDITIONAL INFORMATION. ALL
HANDICAPPED UNITS SHALL INCLUDE HORN/STROBE DEVICES IN EVERY ROOM, INCLUDING
BATHROOM.
12 TYP
SD
F
SD
7
TV
17
6 TYP
TV
EF
3
2
SD
6
SD
6
GFI
GFI
11
14
8
11
STRUCTURED
MEDIA PANEL
17
15
EF
GFI
16
J
3
1
GFI
5
1
OPEN TO BELOW
GFI
4
GFI
8
13 LOADCENTER
PP
Enlarged Unit B3 Electrical Plan - Main Level
1/4" = 1'-0"
Enlarged Unit B3 Electrical Plan - Upper
Level
2
1/4" = 1'-0"
PROVIDE STRUCTURED MEDIA PANEL (SEE PROJECT SPECIFICATIONS). PROVIDE (1) 2" EMT
CONDUIT FROM PANEL TO ACCESSIBLE CORRIDOR CEILING AREA FOR CABLING. SEE LOW
VOLTAGE RISER FOR CABLING REQUIREMENTS. STRUCTURE MEDIA PANEL REQUIRES (1) 20 AMP
120 VOLT ELECTRICAL CIRCUIT.
12
PROVIDE CEILING FAN RATED JUNCTION BOX.
13
CONTRACTOR TO INSTALL LOAD CENTER PANEL FLUSH MOUNTED, MAINTAIN FIRE RATING OF WALL
WHERE APPLICABLE.
14
PROVIDE DUPLEX RECEPTACLE FOR WASHING MACHINE.
ARCHITECTURAL DRAWINGS.
15
PROVIDE 30 AMP, 120/240 VOLT NEMA 14-30R DRYER RECEPTACLE. THIS CIRCUIT MUST BE
PROVIDED WITH A GROUNDED (NEUTRAL) CONDUCTOR AND AN EQUIPMENT GROUNDING
CONDUCTOR. COORDINATE MOUNTING HEIGHT WITH ARCHITECTURAL DRAWINGS.
16
PROVIDE ELECTRICAL CONNECTION OR ELECTRIC WATER HEATER. ELECTRICAL CIRCUITRY SHALL
BE 30 AMPS, 240 VOLTS. UNIT D1 HAS A WATER HEATER CLOSET, REMAINING UNITS HAVE THE
WATER HEATER ON A SHELF ABOVE LAUNDRY MACHINE.
17
ELECTRICAL CIRCUITRY SHALL BE AS DESIGNATED IN THE ELECTRICAL LOADCENTER SCHEDULE
ON THIS SHEET.
TA
OF TE
TE
X
A
S
2
TRENT E BEIGHLE
100821
FE
O
PROVIDE ELECTRICAL CIRCUIT AND 50 AMP 120/240 VOLT RANGE RECEPTACLE. THIS CIRCUIT
MUST BE PROVIDED WITH A GROUNDED (NEUTRAL) CONDUCTOR AND AN EQUIPMENT GROUNDING
CONDUCTOR. COORDINATE MOUNTING HEIGHT WITH ARCHITECTURAL DRAWINGS.
PR
1
Nacogdoches, TX
B.
R
ALL WORK SHALL BE IN ACCORDANCE WITH THE 2005 EDITION OF THE NATIONAL
ELECTRICAL CODE, STATE CODE(S) AND LOCAL CODE(S).
ELECTRICAL CONTRACTOR SHALL VISIT THE SITE TO FAMILIARIZE THEMSELVES WITH
THE SCOPE OF THE PROJECT PRIOR TO BID.
ALL RECEPTACLES SERVING COUNTERTOP AREAS IN THE KITCHEN AND ALL
RECEPTACLES IN THE BATHROOM(S) SHALL BE GFI TYPE.
ALL RECEPTACLES LOCATED OUTSIDE SHALL BE GFI TYPE, SHALL BE LISTED AS
WEATHER-RESISTANT, AND SHALL HAVE WEATHERPROOF IN-USE COVERS.
IN LIVING AND SLEEPING ROOMS, ALL 15 AND 20 AMP, 120 VOLT RECEPTACLES
SHALL BE LISTED TAMPER-RESISTANT RECEPTACLES.
PROVIDE ARC FAULT CIRCUIT BREAKERS FOR CIRCUITS SERVING SLEEPING AREA
OUTLETS. LIVING ROOMS AND BEDROOMS ARE CONSIDERED SLEEPING AREAS.
ELECTRICAL CONTRACTOR SHALL PROVIDE SAFETY SWITCHES FOR ALL HVAC AND
PLUMBING EQUIPMENT IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE.
DEVICES INSTALLED IN FIRE SEPARATION WALLS/CEILINGS SHALL BE INSTALLED IN
ACCORDANCE WITH THE LISTING AND LABELING OF THE RATED ASSEMBLY. DO NOT
INSTALL OUTLET BOXES WITHIN THE SAME STUD SPACE.
SMOKE ALARMS SHALL BE CONNECTED TOGETHER SO THAT WHEN ONE SMOKE ALARM
WITHIN A RESIDENCE SOUNDS, ALL SMOKE ALARMS WITHIN THAT RESIDENCE SOUND.
PROVIDE VISUAL ALARM NOTIFICATION APPLIANCES AS PER THE REQUIREMENTS OF
SECTION 907.9.1.3 INTERNATIONAL BUILDING CODE (IBC) 2000.
VERIFY EXACT LOCATIONS OF BATHROOM EXHAUST FANS WITH MECHANICAL DRAWINGS.
DASHED CIRCUIT LINES REPRESENT SWITCH LEGS.
TYPE NM CABLE MAY BE USED FOR BRANCH WIRING WITHIN EACH DWELLING UNIT
ONLY (WHERE ALLOWABLE BY CODE).
ALL DEVICES AND COVERPLATES SHALL BE WHITE.
EE
A.
LUMBERJACK LOFTS
SFA 1411 ASSOCIATES, L.P.
GENERAL NOTES
Electrical Typical Room
Plans
EXTERIOR WALL LIGHT FIXTURE
DESIGN PARTNERS INTERNATIONAL #104262BK
S
(PATIO)
"RACETRAC" STRIP WITH (4) LAMPS, 24" LENGTH
DESIGN PARTNERS INTERNATIONAL #103010CH
PERMIT SET
(BATHROOM)
LIC
SS
E NS ED IN
G
IONA L EN
PE-SERVICES
F-10841
EXP: 11/30/12
ARCHITECTURE DEMAREST
C ARCHITECTURE DEMAREST, L.P.
ALL RIGHTS RESERVED
DATE
07/16/12
SECURE JUNCTION BOX TO STRUCTURE.
Revision Schedule
No. Date
Description
VERIFY ROUGH-IN LOCATIONS WITH
JOB NO.
10051
SHEET NO.
COPYRIGHT (C) 2011 ARCHITECTURE DEMAREST, L.P. ALL IDEAS, DESIGNS, ARRANGEMENTS, PLANS, AND SPECIFICATIONS INDICATED OR REPRESENTED BY THIS DRAWING AS INSTRUMENTS OF SERVICE ARE AND SHALL REMAIN THE EXCLUSIVE INTELLECTUAL PROPERTY OF ARCHITECTURE DEMAREST, L.P. AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THIS SPECIFIED PROJECT ONLY. NONE OF SUCH
IDEAS, DESIGN, ARRANGEMENTS OR PLANS SHALL BE USED ON ANY OTHER PROJECT OR EXTENSIONS OF THIS PROJECT OR USED BY OR DISCLOSED TO ANY PERSON, FIRM OR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION FORM AND APPROPRIATE COMPENSATION TO ARCHITECTUREDEMAREST, L.P. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. THE CONTRACTOR
SHALL BEAR SOLE RESPONSIBILITY FOR VERIFYING ALL DIMENSIONS ON THIS PROJECT AND NOTIFIYING ARCHITECTURE DEMAREST, L.P. OF ANY DEVIATIONS. THE CONTRACTOR SHALL BEAR SOLE RESPONSIBILITY FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, CONFIRMING COORDINATION AND FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT. ARCHITECTURE DEMAREST, L.P.
WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT.
E303
ELECTRICAL SERVICE #1 MULTI-METER ASSEMBLY SERVES (21) RESIDENCES AND (1) HOUSE LOADCENTER. THE RESIDENCE UNITS
INCLUDED IN THIS CALCULATION ARE:
ELECTRICAL SERVICE #2 MULTI-METER ASSEMBLY SERVES (21) RESIDENCES. THE RESIDENCE UNITS INCLUDED IN THIS
CALCULATION ARE:
ELECTRICAL SERVICE #3 MULTI-METER ASSEMBLY SERVES (27) RESIDENCES. THE RESIDENCE UNITS INCLUDED IN THIS
CALCULATION ARE:
(3) TYPE "A(x)" UNITS
(9) TYPE "A(x)" UNITS
(21) TYPE "A(x)" UNITS
THE FOLLOWING IS A SUMMATION OF THE ELECTRICAL LOADS ASSOCIATED WITH THIS PARTICULAR MULTI-METER ASSEMBLY.
ELECTRICAL LOAD CALCULATION FOR MULTIFAMILY DWELLING - ELECTRICAL SERVICE #2
METHOD FOR DETERMINING FEEDER LOAD NEC 220.84
CONNECTED LOADS TOTAL
TABLE 220.84
DEMAND LOAD
SUM OF LOADS
LARGEST MOTOR
TOTAL
CONNECTED LOADS
646,875VA
CONNECTED LOADS TOTAL
646,875VA @ 37% DEMAND
DEMAND FACTOR
239,345VA
DEMAND LOAD
220.84(C)(1)
220.84(C)(2)
220.84(C)(3)
220.84(C)(3)
220.84(C)(3)
220.84(C)(5)
TABLE 220.84
3VA/SQFT X 20,985 SQFT (COMBINED SQUARE FOOTAGE)
1500VA X 3 X 21 RESIDENCES (SMALL APPLIANCE)
4500VA X 21 RESIDENCES (WATER HEATER)
5000VA X 21 RESIDENCES (DRYER)
8000VA X 21 RESIDENCES (RANGE)
141,000VA (TOTAL OF ELECTRIC HEAT)
CONNECTED LOADS
665,955VA
CONNECTED LOADS TOTAL
665,955VA @ 37% DEMAND
DEMAND FACTOR
246,403VA
DEMAND LOAD
220.84(C)(1)
220.84(C)(2)
220.84(C)(3)
220.84(C)(3)
220.84(C)(3)
220.84(C)(5)
3VA/SQFT X 16,485 SQFT (COMBINED SQUARE FOOTAGE)
1500VA X 3 X 27 RESIDENCES (SMALL APPLIANCE)
4500VA X 27 RESIDENCES (WATER HEATER)
5000VA X 27 RESIDENCES (DRYER)
8000VA X 27 RESIDENCES (RANGE)
135,000VA (TOTAL OF ELECTRIC HEAT)
778,455VA
TABLE 220.84
778,455VA @ 34% DEMAND
264,675VA
30,050VA TOTAL
746VA X 25% = 187VA
30,237VA
TOTAL FEEDER LOAD ASSOCIATED WITH THIS METER CENTER
269,582 VOLT-AMPS / 240 VOLT = 1123 AMPS
TOTAL FEEDER LOAD ASSOCIATED WITH THIS METER CENTER
246,403 VOLT-AMPS / 240 VOLT = 1027 AMPS
TOTAL FEEDER LOAD ASSOCIATED WITH THIS METER CENTER
264,675 VOLT-AMPS / 240 VOLT = 1103 AMPS
1200 AMP 120/240 VOLT 1 PHASE ELECTRICAL SERVICE
1200 AMP 120/240 VOLT 1 PHASE ELECTRICAL SERVICE
1200 AMP 120/240 VOLT 1 PHASE ELECTRICAL SERVICE
SEE OVERALL FLOORPLAN
SHEETS FOR RESIDENCE
LOCATIONS
2-2-2-4 AL SER CABLE
FOR 100 AMP SERVICE
1/0-1/0-1/0-2 AL SER CABLE
FOR 125 AMP SERVICE
RESIDENCE UNITS
TYPE "D1"
REQUIRE 125 AMP
FEEDER, TYPES
"A(x)" AND "B(x)"
REQUIRE 100 AMP
FEEDER
2-2-2-4 AL SER CABLE
FOR 100 AMP SERVICE
1/0-1/0-1/0-2 AL SER CABLE
FOR 125 AMP SERVICE
LOADCENTER
"PP"
120/240V
1PH 3W
125A MLO
RESIDENCE UNITS
TYPE "D1"
REQUIRE 125 AMP
FEEDER, TYPES
"A(x)" AND "B(x)"
REQUIRE 100 AMP
FEEDER
TYPICAL FOR (7)
RESIDENCE UNIT
LOADCENTERS ON
THIS LEVEL
3RD FLOOR RESIDENCES
2-2-2-4 AL SER CABLE
FOR 100 AMP SERVICE
1/0-1/0-1/0-2 AL SER CABLE
FOR 125 AMP SERVICE
RESIDENCE UNITS
TYPE "D1"
REQUIRE 125 AMP
FEEDER, TYPES
"A(x)" AND "B(x)"
REQUIRE 100 AMP
FEEDER
TYPICAL FOR (7)
RESIDENCE UNIT
LOADCENTERS ON
THIS LEVEL
CONCRETE ENCASED
ELECTRODE
2ND FLOOR RESIDENCES
3RD FLOOR RESIDENCES
SEE OVERALL FLOORPLAN
SHEETS FOR RESIDENCE
LOCATIONS
SEE OVERALL FLOORPLAN
SHEETS FOR RESIDENCE
LOCATIONS
LOADCENTER
"PP"
120/240V
1PH 3W
125A MLO
TYPICAL FOR (9)
RESIDENCE UNIT
LOADCENTERS ON
THIS LEVEL
2-2-2-4 AL SER CABLE
FOR 100 AMP SERVICE
LOADCENTER
"PP"
120/240V
1PH 3W
125A MLO
RESIDENCE UNITS
TYPES "A(x)" AND
"B(x)" REQUIRE 100
AMP FEEDER
TYPICAL FOR (7)
RESIDENCE UNIT
LOADCENTERS ON
THIS LEVEL
TYPICAL FOR (9)
RESIDENCE UNIT
LOADCENTERS ON
THIS LEVEL
TA
O
METAL WATER
PIPE
BUILDING STEEL
(IF AVAILABLE)
SEE OVERALL FLOORPLAN
SHEETS FOR RESIDENCE
LOCATIONS
250 MCM AL
GROUP METERING
MODULE,
120/240 VOLT,
(24) 125 AMP
1PH METER
SOCKET
POSITIONS,
1200 AMP MAIN
1200
M
M
M
M
M
M
100
100
100
100
100
125
M
M
M
M
M
M
125
100
100
100
100
100
M
M
M
M
M
M
125
125
100
100
M
M
M
M
100
125
2-2-2-4 AL SER CABLE
FOR 100 AMP SERVICE
1/0-1/0-1/0-2 AL SER CABLE
FOR 125 AMP SERVICE
125
RESIDENCE UNITS
TYPE "D1"
REQUIRE 125 AMP
FEEDER, TYPES
"A(x)" AND "B(x)"
REQUIRE 100 AMP
FEEDER
125
100
#6 CU TO 10'X3/4"
GROUND ROD
TO UTILITY
TRANSFORMER
LOADCENTER
"PP"
120/240V
1PH 3W
125A MLO
TYPICAL FOR (7)
RESIDENCE UNIT
LOADCENTERS ON
THIS LEVEL
SEE OVERALL FLOORPLAN
SHEETS FOR RESIDENCE
LOCATIONS
250 MCM AL
HOUSE
LOADCENTER
"HP1"
120/240V
1PH 3W
125A MLO
GROUP METERING
MODULE,
120/240 VOLT,
(24) 125 AMP
1PH METER
SOCKET
POSITIONS,
1200 AMP MAIN
HOUSE
LOADCENTER
REQUIRES 125
AMP FEEDER
100
1200
1ST FLOOR RESIDENCES
EXTERIOR GRADE LEVEL
M
M
M
M
M
M
100
100
100
125
125
125
M
M
M
M
M
M
ELECTRICAL SERVICE #1
125
100
100
100
125
125
M
M
M
M
M
M
125
125
100
M
M
M
125
125
2-2-2-4 AL SER CABLE
FOR 100 AMP SERVICE
1/0-1/0-1/0-2 AL SER CABLE
FOR 125 AMP SERVICE
125
RESIDENCE UNITS
TYPE "D1"
REQUIRE 125 AMP
FEEDER, TYPES
"A(x)" AND "B(x)"
REQUIRE 100 AMP
FEEDER
100
100
#6 CU TO 10'X3/4"
GROUND ROD
BUILDING STEEL
(IF AVAILABLE)
250 MCM AL
GROUP METERING
MODULE,
120/240 VOLT,
(30) 125 AMP
1PH METER
SOCKET
POSITIONS,
1200 AMP MAIN
LOADCENTER
"PP"
120/240V
1PH 3W
125A MLO
TYPICAL FOR (7)
RESIDENCE UNIT
LOADCENTERS ON
THIS LEVEL
1200
M
M
M
M
M
M
100
100
100
100
100
100
M
M
M
M
M
M
100
100
100
100
100
100
M
M
M
M
M
M
100
100
100
100
100
100
M
M
M
M
M
M
100
100
100
M
M
M
100
100
SS
E NS ED IN
G
IONA L EN
PE-SERVICES
F-10841
EXP: 11/30/12
LOADCENTER
"PP"
120/240V
1PH 3W
125A MLO
100
100
100
RESIDENCE UNITS
TYPES "A(x)" AND
"B(x)" REQUIRE 100
AMP FEEDER
TYPICAL FOR (9)
RESIDENCE UNIT
LOADCENTERS ON
THIS LEVEL
ARCHITECTURE DEMAREST
C ARCHITECTURE DEMAREST, L.P.
ALL RIGHTS RESERVED
100
1ST FLOOR RESIDENCES
EXTERIOR GRADE LEVEL
ELECTRICAL SERVICE #2
2-2-2-4 AL SER CABLE
FOR 100 AMP SERVICE
DATE
07/16/12
#6 CU TO 10'X3/4"
GROUND ROD
ELECTRICAL SERVICE #3
TO UTILITY
TRANSFORMER
(4) SETS OF (3) 500 MCM AL
(4) 4" CONDUITS
LIC
SEE OVERALL FLOORPLAN
SHEETS FOR RESIDENCE
LOCATIONS
125
1ST FLOOR RESIDENCES
EXTERIOR GRADE LEVEL
TO UTILITY
TRANSFORMER
(4) SETS OF (3) 500 MCM AL
(4) 4" CONDUITS
1
METAL WATER
PIPE
BUILDING STEEL
(IF AVAILABLE)
A
100821
2ND FLOOR RESIDENCES
FE
METAL WATER
PIPE
OF TE
TE
X
TRENT E BEIGHLE
CONCRETE ENCASED
ELECTRODE
2ND FLOOR RESIDENCES
LOADCENTER
"PP"
120/240V
1PH 3W
125A MLO
PR
CONCRETE ENCASED
ELECTRODE
RESIDENCE UNITS
TYPES "A(x)" AND
"B(x)" REQUIRE 100
AMP FEEDER
TYPICAL FOR (7)
RESIDENCE UNIT
LOADCENTERS ON
THIS LEVEL
LOADCENTER
"PP"
120/240V
1PH 3W
125A MLO
S
RESIDENCE UNITS
TYPE "D1"
REQUIRE 125 AMP
FEEDER, TYPES
"A(x)" AND "B(x)"
REQUIRE 100 AMP
FEEDER
2-2-2-4 AL SER CABLE
FOR 100 AMP SERVICE
LOADCENTER
"PP"
120/240V
1PH 3W
125A MLO
3RD FLOOR RESIDENCES
SEE OVERALL FLOORPLAN
SHEETS FOR RESIDENCE
LOCATIONS
2-2-2-4 AL SER CABLE
FOR 100 AMP SERVICE
1/0-1/0-1/0-2 AL SER CABLE
FOR 125 AMP SERVICE
SEE OVERALL FLOORPLAN
SHEETS FOR RESIDENCE
LOCATIONS
SEE OVERALL FLOORPLAN
SHEETS FOR RESIDENCE
LOCATIONS
PERMIT SET
HOUSE LOADS
3VA/SQFT X 20,625 SQFT (COMBINED SQUARE FOOTAGE)
1500VA X 3 X 21 RESIDENCES (SMALL APPLIANCE)
4500VA X 21 RESIDENCES (WATER HEATER)
5000VA X 21 RESIDENCES (DRYER)
8000VA X 21 RESIDENCES (RANGE)
123,000VA (TOTAL OF ELECTRIC HEAT)
METHOD FOR DETERMINING FEEDER LOAD NEC 220.84
Nacogdoches, TX
220.84(C)(1)
220.84(C)(2)
220.84(C)(3)
220.84(C)(3)
220.84(C)(3)
220.84(C)(5)
DEMAND FACTOR
ELECTRICAL LOAD CALCULATION FOR MULTIFAMILY DWELLING - ELECTRICAL SERVICE #3
R
METHOD FOR DETERMINING FEEDER LOAD NEC 220.84
CONNECTED LOADS
THE FOLLOWING IS A SUMMATION OF THE ELECTRICAL LOADS ASSOCIATED WITH THIS PARTICULAR MULTI-METER ASSEMBLY.
EE
ELECTRICAL LOAD CALCULATION FOR MULTIFAMILY DWELLING - ELECTRICAL SERVICE #1
(6) TYPE "B(x)" UNITS
LUMBERJACK LOFTS
SFA 1411 ASSOCIATES, L.P.
THE FOLLOWING IS A SUMMATION OF THE ELECTRICAL LOADS ASSOCIATED WITH THIS PARTICULAR MULTI-METER ASSEMBLY.
(12) TYPE "D(x)" UNITS
Electrical Riser
Diagrams
(6) TYPE "D(x)" UNITS
S
(12) TYPE "B(x) UNITS
Revision Schedule
No. Date
Description
(4) SETS OF (3) 500 MCM AL
(4) 4" CONDUITS
Electrical Riser Diagram Services 1,2, and 3
NOT
DRAWN
TO SCALE
3/16"
= 1'-0"
JOB NO.
10051
SHEET NO.
COPYRIGHT (C) 2011 ARCHITECTURE DEMAREST, L.P. ALL IDEAS, DESIGNS, ARRANGEMENTS, PLANS, AND SPECIFICATIONS INDICATED OR REPRESENTED BY THIS DRAWING AS INSTRUMENTS OF SERVICE ARE AND SHALL REMAIN THE EXCLUSIVE INTELLECTUAL PROPERTY OF ARCHITECTURE DEMAREST, L.P. AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THIS SPECIFIED PROJECT ONLY. NONE OF SUCH
IDEAS, DESIGN, ARRANGEMENTS OR PLANS SHALL BE USED ON ANY OTHER PROJECT OR EXTENSIONS OF THIS PROJECT OR USED BY OR DISCLOSED TO ANY PERSON, FIRM OR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION FORM AND APPROPRIATE COMPENSATION TO ARCHITECTUREDEMAREST, L.P. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. THE CONTRACTOR
SHALL BEAR SOLE RESPONSIBILITY FOR VERIFYING ALL DIMENSIONS ON THIS PROJECT AND NOTIFIYING ARCHITECTURE DEMAREST, L.P. OF ANY DEVIATIONS. THE CONTRACTOR SHALL BEAR SOLE RESPONSIBILITY FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, CONFIRMING COORDINATION AND FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT. ARCHITECTURE DEMAREST, L.P.
WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT.
E401
ELECTRICAL SERVICE #4 MULTI-METER ASSEMBLY SERVES (21) RESIDENCES AND (1) HOUSE LOADCENTER. THE RESIDENCE UNITS
INCLUDED IN THIS CALCULATION ARE:
ELECTRICAL SERVICE #5 MULTI-METER ASSEMBLY SERVES (21) RESIDENCES, (1) HOUSE LOADCENTER AND (1) MAINTENANCE
BUILDING LOADCENTER. THE RESIDENCE UNITS INCLUDED IN THIS CALCULATION ARE:
ELECTRICAL SERVICE #6 MULTI-METER ASSEMBLY SERVES (24) RESIDENCES. THE RESIDENCE UNITS INCLUDED IN THIS
CALCULATION ARE:
(5) TYPE "A(x)" UNITS
(2) TYPE "A(x)" UNITS
(3) TYPE "A(x)" UNITS
ELECTRICAL LOAD CALCULATION FOR MULTIFAMILY DWELLING - ELECTRICAL SERVICE #5
CONNECTED LOADS TOTAL
DEMAND FACTOR
TABLE 220.84
DEMAND LOAD
HOUSE LOADS
SUM OF LOADS
LARGEST MOTOR
TOTAL
3VA/SQFT X 19,855 SQFT (COMBINED SQUARE FOOTAGE)
1500VA X 3 X 21 RESIDENCES (SMALL APPLIANCE)
4500VA X 21 RESIDENCES (WATER HEATER)
5000VA X 21 RESIDENCES (DRYER)
8000VA X 21 RESIDENCES (RANGE)
123,000VA (TOTAL OF ELECTRIC HEAT)
CONNECTED LOADS
644,565VA
CONNECTED LOADS TOTAL
644,565VA @ 37% DEMAND
DEMAND FACTOR
238,489VA
DEMAND LOAD
23,447VA TOTAL
746VA X 25% = 187VA
23,634VA
HOUSE / MANTCE. LOADS
220.84(C)(1)
220.84(C)(2)
220.84(C)(3)
220.84(C)(3)
220.84(C)(3)
220.84(C)(5)
TABLE 220.84
SUM OF LOADS
LARGEST MOTOR
TOTAL
3VA/SQFT X 20,985 SQFT (COMBINED SQUARE FOOTAGE)
1500VA X 3 X 21 RESIDENCES (SMALL APPLIANCE)
4500VA X 21 RESIDENCES (WATER HEATER)
5000VA X 21 RESIDENCES (DRYER)
8000VA X 21 RESIDENCES (RANGE)
132,000VA (TOTAL OF ELECTRIC HEAT)
CONNECTED LOADS
656,955VA
CONNECTED LOADS TOTAL
656,955VA @ 37% DEMAND
DEMAND FACTOR
243,073VA
DEMAND LOAD
220.84(C)(1)
220.84(C)(2)
220.84(C)(3)
220.84(C)(3)
220.84(C)(3)
220.84(C)(5)
3VA/SQFT X 24,690 SQFT (COMBINED SQUARE FOOTAGE)
1500VA X 3 X 24 RESIDENCES (SMALL APPLIANCE)
4500VA X 24 RESIDENCES (WATER HEATER)
5000VA X 24 RESIDENCES (DRYER)
8000VA X 24 RESIDENCES (RANGE)
147,000VA (TOTAL OF ELECTRIC HEAT)
699,690VA
TABLE 220.84
699,690VA @ 35% DEMAND
244,892VA
37,545VA TOTAL
746VA X 25% = 187VA
37,723VA
TOTAL FEEDER LOAD ASSOCIATED WITH THIS METER CENTER
262,123 VOLT-AMPS / 240 VOLT = 1092 AMPS
TOTAL FEEDER LOAD ASSOCIATED WITH THIS METER CENTER
280,796 VOLT-AMPS / 240 VOLT = 1170 AMPS
TOTAL FEEDER LOAD ASSOCIATED WITH THIS METER CENTER
244,892 VOLT-AMPS / 240 VOLT = 1020 AMPS
1200 AMP 120/240 VOLT 1 PHASE ELECTRICAL SERVICE
1200 AMP 120/240 VOLT 1 PHASE ELECTRICAL SERVICE
1200 AMP 120/240 VOLT 1 PHASE ELECTRICAL SERVICE
SEE OVERALL FLOORPLAN
SHEETS FOR RESIDENCE
LOCATIONS
2-2-2-4 AL SER CABLE
FOR 100 AMP SERVICE
1/0-1/0-1/0-2 AL SER CABLE
FOR 125 AMP SERVICE
RESIDENCE UNITS
TYPE "D1"
REQUIRE 125 AMP
FEEDER, TYPES
"A(x)" AND "B(x)"
REQUIRE 100 AMP
FEEDER
2-2-2-4 AL SER CABLE
FOR 100 AMP SERVICE
1/0-1/0-1/0-2 AL SER CABLE
FOR 125 AMP SERVICE
LOADCENTER
"PP"
120/240V
1PH 3W
125A MLO
RESIDENCE UNITS
TYPE "D1"
REQUIRE 125 AMP
FEEDER, TYPES
"A(x)" AND "B(x)"
REQUIRE 100 AMP
FEEDER
TYPICAL FOR (7)
RESIDENCE UNIT
LOADCENTERS ON
THIS LEVEL
RESIDENCE UNITS
TYPE "D1"
REQUIRE 125 AMP
FEEDER, TYPES
"A(x)" AND "B(x)"
REQUIRE 100 AMP
FEEDER
2-2-2-4 AL SER CABLE
FOR 100 AMP SERVICE
1/0-1/0-1/0-2 AL SER CABLE
FOR 125 AMP SERVICE
LOADCENTER
"PP"
120/240V
1PH 3W
125A MLO
RESIDENCE UNITS
TYPE "D1"
REQUIRE 125 AMP
FEEDER, TYPES
"A(x)" AND "B(x)"
REQUIRE 100 AMP
FEEDER
TYPICAL FOR (7)
RESIDENCE UNIT
LOADCENTERS ON
THIS LEVEL
3RD FLOOR RESIDENCES
SEE OVERALL FLOORPLAN
SHEETS FOR RESIDENCE
LOCATIONS
2-2-2-4 AL SER CABLE
FOR 100 AMP SERVICE
1/0-1/0-1/0-2 AL SER CABLE
FOR 125 AMP SERVICE
SEE OVERALL FLOORPLAN
SHEETS FOR RESIDENCE
LOCATIONS
SEE OVERALL FLOORPLAN
SHEETS FOR RESIDENCE
LOCATIONS
3RD FLOOR RESIDENCES
CONCRETE ENCASED
ELECTRODE
ELECTRICAL LOAD CALCULATION FOR MULTIFAMILY DWELLING - ELECTRICAL SERVICE #6
METHOD FOR DETERMINING FEEDER LOAD NEC 220.84
METHOD FOR DETERMINING FEEDER LOAD NEC 220.84
2-2-2-4 AL SER CABLE
FOR 100 AMP SERVICE
1/0-1/0-1/0-2 AL SER CABLE
FOR 125 AMP SERVICE
RESIDENCE UNITS
TYPE "D1"
REQUIRE 125 AMP
FEEDER, TYPES
"A(x)" AND "B(x)"
REQUIRE 100 AMP
FEEDER
TYPICAL FOR (7)
RESIDENCE UNIT
LOADCENTERS ON
THIS LEVEL
CONCRETE ENCASED
ELECTRODE
SEE OVERALL FLOORPLAN
SHEETS FOR RESIDENCE
LOCATIONS
2-2-2-4 AL SER CABLE
FOR 100 AMP SERVICE
1/0-1/0-1/0-2 AL SER CABLE
FOR 125 AMP SERVICE
LOADCENTER
"PP"
120/240V
1PH 3W
125A MLO
RESIDENCE UNITS
TYPE "D1"
REQUIRE 125 AMP
FEEDER, TYPES
"A(x)" AND "B(x)"
REQUIRE 100 AMP
FEEDER
TYPICAL FOR (7)
RESIDENCE UNIT
LOADCENTERS ON
THIS LEVEL
CONCRETE ENCASED
ELECTRODE
2ND FLOOR RESIDENCES
LOADCENTER
"PP"
120/240V
1PH 3W
125A MLO
TYPICAL FOR (8)
RESIDENCE UNIT
LOADCENTERS ON
THIS LEVEL
2ND FLOOR RESIDENCES
METAL WATER
PIPE
SEE OVERALL FLOORPLAN
SHEETS FOR RESIDENCE
LOCATIONS
250 MCM AL
GROUP METERING
MODULE,
120/240 VOLT,
(24) 125 AMP
1PH METER
SOCKET
POSITIONS,
1200 AMP MAIN
1200
M
M
M
M
M
M
100
125
100
100
125
100
M
M
M
M
M
M
100
100
125
100
100
125
M
M
M
M
M
M
100
100
100
125
M
M
M
M
125
100
2-2-2-4 AL SER CABLE
FOR 100 AMP SERVICE
1/0-1/0-1/0-2 AL SER CABLE
FOR 125 AMP SERVICE
100
RESIDENCE UNITS
TYPE "D1"
REQUIRE 125 AMP
FEEDER, TYPES
"A(x)" AND "B(x)"
REQUIRE 100 AMP
FEEDER
125
100
TYPICAL FOR (7)
RESIDENCE UNIT
LOADCENTERS ON
THIS LEVEL
HOUSE
LOADCENTER
"HP2"
120/240V
1PH 3W
125A MLO
GROUP METERING
MODULE,
120/240 VOLT,
(24) 125 AMP
1PH METER
SOCKET
POSITIONS,
1200 AMP MAIN
HOUSE
LOADCENTER
REQUIRES 125
AMP FEEDER
1200
1ST FLOOR RESIDENCES
M
M
M
M
M
M
100
125
100
125
100
M
M
M
M
M
M
#6 CU TO 10'X3/4"
GROUND ROD
TO UTILITY
TRANSFORMER
125
100
100
125
100
125
M
M
M
M
M
M
100
125
100
100
125
M
M
M
M
M
125
100
125
125
125
2-2-2-4 AL SER CABLE
FOR 100 AMP SERVICE
1/0-1/0-1/0-2 AL SER CABLE
FOR 125 AMP SERVICE
RESIDENCE UNITS
TYPE "D1"
REQUIRE 125 AMP
FEEDER, TYPES
"A(x)" AND "B(x)"
REQUIRE 100 AMP
FEEDER
HOUSE
LOADCENTER
"HP3"
120/240V
1PH 3W
125A MLO
LOADCENTER
"PP"
120/240V
1PH 3W
125A MLO
TYPICAL FOR (7)
RESIDENCE UNIT
LOADCENTERS ON
THIS LEVEL
MAINTENANCE
BUILDING
LOADCENTER
"MB1"
120/240V
1PH 3W
125A MCB
HOUSE
LOADCENTER
REQUIRES 125
AMP FEEDER
ELECTRICAL SERVICE #5
GROUP METERING
MODULE,
120/240 VOLT,
(24) 125 AMP
1PH METER
SOCKET
POSITIONS,
1200 AMP MAIN
#6 CU TO 10'X3/4"
GROUND ROD AND
METAL WATER
PIPE
100
1ST FLOOR RESIDENCES
EXTERIOR GRADE LEVEL
ELECTRICAL SERVICE #4
TO UTILITY
TRANSFORMER
100
SEE OVERALL FLOORPLAN
SHEETS FOR RESIDENCE
LOCATIONS
250 MCM AL
MAINTENANCE
BUILDING
LOADCENTER
REQUIRES 125
AMP FEEDER
100
EXTERIOR GRADE LEVEL
#6 CU TO 10'X3/4"
GROUND ROD
LOADCENTER
"PP"
120/240V
1PH 3W
125A MLO
SEE OVERALL FLOORPLAN
SHEETS FOR RESIDENCE
LOCATIONS
250 MCM AL
100821
BUILDING STEEL
(IF AVAILABLE)
MAINTENANCE BUILDING
1200
M
M
M
M
M
M
100
125
125
100
100
100
M
M
M
M
M
M
100
125
100
125
125
100
M
M
M
M
M
M
100
100
100
125
100
125
M
M
M
M
M
M
125
100
100
100
100
2-2-2-4 AL SER CABLE
FOR 100 AMP SERVICE
1/0-1/0-1/0-2 AL SER CABLE
FOR 125 AMP SERVICE
RESIDENCE UNITS
TYPE "D1"
REQUIRE 125 AMP
FEEDER, TYPES
"A(x)" AND "B(x)"
REQUIRE 100 AMP
FEEDER
LIC
SS
E NS ED IN
G
IONA L EN
PE-SERVICES
F-10841
EXP: 11/30/12
LOADCENTER
"PP"
120/240V
1PH 3W
125A MLO
TYPICAL FOR (8)
RESIDENCE UNIT
LOADCENTERS ON
THIS LEVEL
125
1ST FLOOR RESIDENCES
EXTERIOR GRADE LEVEL
FE
O
BUILDING STEEL
(IF AVAILABLE)
A
TRENT E BEIGHLE
PR
BUILDING STEEL
(IF AVAILABLE)
METAL WATER
PIPE
OF TE
TE
X
R
METAL WATER
PIPE
TA
S
S
2ND FLOOR RESIDENCES
TYPICAL FOR (8)
RESIDENCE UNIT
LOADCENTERS ON
THIS LEVEL
3RD FLOOR RESIDENCES
SEE OVERALL FLOORPLAN
SHEETS FOR RESIDENCE
LOCATIONS
LOADCENTER
"PP"
120/240V
1PH 3W
125A MLO
LOADCENTER
"PP"
120/240V
1PH 3W
125A MLO
Nacogdoches, TX
220.84(C)(1)
220.84(C)(2)
220.84(C)(3)
220.84(C)(3)
220.84(C)(3)
220.84(C)(5)
(9) TYPE "D(x)" UNITS
EE
ELECTRICAL LOAD CALCULATION FOR MULTIFAMILY DWELLING - ELECTRICAL SERVICE #4
(12) TYPE "B(x)" UNITS
THE FOLLOWING IS A SUMMATION OF THE ELECTRICAL LOADS ASSOCIATED WITH THIS PARTICULAR MULTI-METER ASSEMBLY.
THE FOLLOWING IS A SUMMATION OF THE ELECTRICAL LOADS ASSOCIATED WITH THIS PARTICULAR MULTI-METER ASSEMBLY.
METHOD FOR DETERMINING FEEDER LOAD NEC 220.84
CONNECTED LOADS
(9) TYPE "D(x)" UNITS
LUMBERJACK LOFTS
SFA 1411 ASSOCIATES, L.P.
THE FOLLOWING IS A SUMMATION OF THE ELECTRICAL LOADS ASSOCIATED WITH THIS PARTICULAR MULTI-METER ASSEMBLY.
(10) TYPE "B(x)" UNITS
Electrical Riser
Diagrams
(6) TYPE "D(x)" UNITS
PERMIT SET
(10) TYPE "B(x) UNITS
ARCHITECTURE DEMAREST
C ARCHITECTURE DEMAREST, L.P.
ALL RIGHTS RESERVED
(3) #1/0 AL
(1) #4 AL GRD
1-1/2" CONDUIT
#6 CU TO 10'X3/4"
GROUND ROD
ELECTRICAL SERVICE #6
TO UTILITY
TRANSFORMER
DATE
07/16/12
(4) SETS OF (3) 500 MCM AL
(4) 4" CONDUITS
1
(4) SETS OF (3) 500 MCM AL
(4) 4" CONDUITS
(4) SETS OF (3) 500 MCM AL
(4) 4" CONDUITS
Revision Schedule
No. Date
Description
Electrical Riser Diagram Services 4,5, and 6
NOT DRAWN
TO SCALE
3/16"
= 1'-0"
JOB NO.
10051
SHEET NO.
COPYRIGHT (C) 2011 ARCHITECTURE DEMAREST, L.P. ALL IDEAS, DESIGNS, ARRANGEMENTS, PLANS, AND SPECIFICATIONS INDICATED OR REPRESENTED BY THIS DRAWING AS INSTRUMENTS OF SERVICE ARE AND SHALL REMAIN THE EXCLUSIVE INTELLECTUAL PROPERTY OF ARCHITECTURE DEMAREST, L.P. AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THIS SPECIFIED PROJECT ONLY. NONE OF SUCH
IDEAS, DESIGN, ARRANGEMENTS OR PLANS SHALL BE USED ON ANY OTHER PROJECT OR EXTENSIONS OF THIS PROJECT OR USED BY OR DISCLOSED TO ANY PERSON, FIRM OR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION FORM AND APPROPRIATE COMPENSATION TO ARCHITECTUREDEMAREST, L.P. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. THE CONTRACTOR
SHALL BEAR SOLE RESPONSIBILITY FOR VERIFYING ALL DIMENSIONS ON THIS PROJECT AND NOTIFIYING ARCHITECTURE DEMAREST, L.P. OF ANY DEVIATIONS. THE CONTRACTOR SHALL BEAR SOLE RESPONSIBILITY FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, CONFIRMING COORDINATION AND FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT. ARCHITECTURE DEMAREST, L.P.
WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT.
E402
Branch Panel: CH
Branch Panel: MB1
Location: ELEC/MDF 117
Supply From:
Mounting: Surface
Enclosure:
Volts: 120/240 Single
Phases: 1
Wires: 3
A.I.C. Rating:
Mains Type:
Mains Rating: 600 A
MCB Rating: 600 A
Volts: 120/240 Single
Phases: 1
Wires: 3
Location:
Supply From:
Mounting: Surface
Enclosure:
Notes:
Circuit Description
Clubhouse Receptacles
Clubhouse Receptacles
Clubhouse Receptacles
Clubhouse Receptacles
Clubhouse Receptacles
Clubhouse Receptacles
Clubhouse Receptacles
Clubhouse Receptacles
Clubhouse Receptacles
Clubhouse Receptacles
Clubhouse Receptacles
Clubhouse Receptacles
Clubhouse Receptacles
Clubhouse Receptacles
Clubhouse Receptacles
Clubhouse Receptacles
Clubhouse Receptacles
Trip
20 A
20 A
20 A
20 A
20 A
20 A
20 A
20 A
20 A
20 A
20 A
20 A
20 A
20 A
20 A
20 A
20 A
AHU-3
60 A
AHU-3
60 A
Clubhouse Receptacles
Clubhouse Receptacles
Clubhouse Receptacles
20 A
20 A
20 A
HVAC
Clubhouse Lighting
Clubhouse Lighting
Clubhouse Lighting
Clubhouse Receptacles
Clubhouse Receptacles
Clubhouse Receptacles
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
B
A
Trip
900 VA
3936 VA
180 VA
180 VA
3936 VA
3936 VA
180 VA
180 VA
3936 VA
3936 VA
900 VA
360 VA
3936 VA
1680 VA
360 VA
180 VA
1680 VA
360 VA
900 VA
360 VA
720 VA
360 VA
360 VA
360 VA
180 VA
360 VA
720 VA
360 VA
982 VA
360 VA
360 VA
180 VA
360 VA
900 VA
6720 VA
6720 VA
720 VA
540 VA
6720 VA
60 A
AHU-3
A
6720 VA
180 VA
360 VA
6720 VA
6720 VA
540 VA
720 VA
360 VA
360 VA
360 VA
1260 VA
360 VA
2250 VA
30 A
180 VA
448 VA
2250 VA
20 A
800 VA
20 A
1765 VA
20 A
1915 VA
20 A
180 VA
20 A
180 VA
20 A
180 VA
20 A
0 VA
20 A
0 VA
20 A
0 VA
20 A
0 VA
20 A
0 VA
20 A
0 VA
20 A
0 VA
20 A
0 VA
49247 VA
Total...
410 A
Total...
300 VA
1006 VA
700 VA
180 VA
180 VA
180 VA
180 VA
0 VA
0 VA
0 VA
0 VA
0 VA
0 VA
0 VA
0 VA
20160 VA
410 A
Circuit Description
50 A
CU-3
50 A
CU-3
50 A
CU-3
20 A
MSS-1
20 A
20 A
20 A
20 A
20 A
20 A
20 A
20 A
20 A
20 A
20 A
Clubhouse Receptacles
Clubhouse Receptacles
Clubhouse Receptacles
Clubhouse Receptacles
Clubhouse Receptacles
Clubhouse Receptacles
Clubhouse Receptacles
Clubhouse Receptacles
Clubhouse Receptacles
Clubhouse Receptacles
Clubhouse Receptacles
20 A
Clubhouse Receptacles
20 A
20 A
20 A
20 A
20 A
20 A
20 A
20 A
20 A
20 A
20 A
20 A
20 A
20 A
20 A
20 A
20 A
20 A
20 A
20 A
20 A
20 A
Clubhouse Receptacles
Clubhouse Receptacles
Clubhouse Receptacles
Clubhouse Receptacles
Clubhouse Receptacles
Clubhouse Receptacles
Clubhouse Lighting
Clubhouse Ceiling Fans
Clubhouse Lighting
Clubhouse Lighting
Clubhouse Receptacles
Clubhouse Receptacles
Clubhouse Receptacles
Clubhouse Receptacles
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
CKT
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
44
46
48
50
52
54
56
58
60
62
64
66
68
70
72
74
76
78
80
82
84
CKT
1
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39
41
Circuit Description
Maintenance Building Receptacles
Maintenance Building Receptacles
Maintenance Building Receptacles
Trip
20 A
20 A
20 A
Heating
60 A
Exhaust Fan
Basketball Court Lighting
Basketball Court Lighting
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
20 A
20 A
20 A
20 A
20 A
20 A
20 A
20 A
20 A
20 A
20 A
20 A
20 A
20 A
Spare
20 A
Spare
20 A
Total...
Total...
B
720
A
B
540
540
720
540
180
5000
5000
1380
1380
470
531
1200
0
1200
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
9740 VA
81 A
Trip
20 A
20 A
20 A
Circuit Description
Maintenance Building Receptacles
Maintenance Building Receptacles
Maintenance Building Receptacles
20 A
PTAC Unit
20 A
--------------
Lighting
Space
Space
Space
Space
Space
Space
Space
Space
Space
Space
Space
Space
Space
--
Space
--
Space
CKT
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
6380 VA
81 A
Legend:
Load Classification
Cooling
Heating
Lighting
Lighting - Dwelling Unit
Other
Power
Receptacle
Connected Load
470 VA
10000 VA
472 VA
59 VA
2760 VA
2400 VA
3240 VA
Demand Factor
100.00%
100.00%
125.00%
100.00%
100.00%
100.00%
100.00%
Estimated Demand
470 VA
10000 VA
590 VA
59 VA
2760 VA
2400 VA
3240 VA
Panel Totals
Total Conn. Load:
Total Est. Demand:
Total Conn.:
Total Est. Demand:
19401 VA
19519 VA
81 A
81 A
PERMIT SET
...
Provide 150A Sub-Feed breaker for panel "PQLA"
Connected Load
23716 VA
4500 VA
472 VA
6114 VA
44030 VA
18720 VA
Demand Factor
100.00%
100.00%
125.00%
66.89%
100.00%
76.71%
Estimated Demand
23716 VA
4500 VA
590 VA
4090 VA
44030 VA
14360 VA
Panel Totals
Total Conn. Load:
Total Est. Demand:
Total Conn.:
Total Est. Demand:
97552 VA
91286 VA
406 A
380 A
Branch Panel: HP1
Branch Panel: HP2
Volts: 120/240 Single
Phases: 1
Wires: 3
A.I.C. Rating:
Mains Type:
Mains Rating: 125 A
MCB Rating: 225 A
Volts: 120/240 Single
Phases: 1
Wires: 3
Location:
Supply From:
Mounting: Surface
Enclosure:
Notes:
A.I.C. Rating:
Mains Type:
Mains Rating: 225 A
MCB Rating: 225 A
Volts: 120/240 Single
Phases: 1
Wires: 3
Location:
Supply From:
Mounting: Surface
Enclosure:
Notes:
A.I.C. Rating:
Mains Type:
Mains Rating: 225 A
MCB Rating: 225 A
Notes:
TA
OF TE
TE
XA
S
Location:
Supply From:
Mounting: Surface
Enclosure:
Branch Panel: HP3
S
Load Classification
Cooling
HVAC
Lighting
Lighting - Dwelling Unit
Other
Receptacle
Nacogdoches, TX
CKT
1
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39
41
43
45
47
49
51
53
55
57
59
61
63
65
67
69
71
73
75
77
79
81
83
B
LUMBERJACK LOFTS
SFA 1411 ASSOCIATES, L.P.
A
Electrical Panel
Schedules
Notes:
A.I.C. Rating:
Mains Type:
Mains Rating: 225 A
MCB Rating: 225 A
TRENT E BEIGHLE
O
FE
A
CKT
1
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39
41
Circuit Description
Lighting
Lighting
Receptacle
Receptacle
Fire Alarm Panel
Receptacle
Spare
IDF Room Power
IDF Room Mini-Split
Trip
20 A
20 A
20 A
20 A
20 A
20 A
20 A
20 A
20 A
Heating
30 A
Site Lighting
Site Lighting
20 A
20 A
Site Lighting
20 A
Lighting - Exterior
Spare
20 A
20 A
Spare
20 A
Spare
20 A
Total...
Total...
B
1154
A
B
1199
1135
1080
1080
1080
1080
500
1260
180
180
0
180
500
500
1680
2000
2000
2000
2000
1680
0
916
916
0
0
1374
1374
0
0
1374
1374
0
0
750
0
0
0
0
0
0
0
15036 VA
125 A
A
Trip
20 A
20 A
20 A
20 A
20 A
20 A
20 A
Circuit Description
Lighting
Receptacle
Receptacle
Receptacle
Receptacle
Receptacle
IDF Room Power
30 A
Heating
20 A
20 A
20 A
20 A
20 A
20 A
20 A
20 A
20 A
20 A
Other
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
20 A
Spare
20 A
Spare
CKT
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
CKT
1
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39
41
Circuit Description
Lighting
Lighting
Receptacle
Receptacle
Receptacle
Receptacle
Receptacle
Power
IDF Room Mini-Split
Trip
20 A
20 A
20 A
20 A
20 A
20 A
20 A
20 A
20 A
Site Lighting
20 A
Signage
Lighting - Exterior
Gate Power
Gate Power
Receptacle
Receptacle
Receptacle
Power
20 A
20 A
20 A
20 A
20 A
20 A
20 A
20 A
Power
20 A
FACP
20 A
Total...
Total...
7664 VA
129 A
Legend:
B
871
A
B
726
906
1260
1260
1260
900
180
1440
180
180
180
180
500
500
1680
2000
2000
1374
1374
500
0
1200
750
0
0
500
500
0
0
180
180
0
0
180
500
0
0
500
500
12641 VA
105 A
0
0
A
Trip
20 A
20 A
20 A
20 A
20 A
20 A
20 A
Lighting
Receptacle
Receptacle
Receptacle
Receptacle
Receptacle
Power
Circuit Description
20 A
Heating
20 A
20 A
20 A
20 A
20 A
20 A
20 A
20 A
20 A
20 A
FACP
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
Spare
20 A
Spare
20 A
Spare
Connected Load
8000 VA
3382 VA
750 VA
3470 VA
8328 VA
6120 VA
Demand Factor
100.00%
92.66%
125.00%
100.00%
100.00%
100.00%
Estimated Demand
8000 VA
3134 VA
938 VA
3470 VA
8328 VA
6120 VA
Panel Totals
Total Conn. Load:
Total Est. Demand:
Total Conn.:
Total Est. Demand:
30050 VA
29989 VA
125 A
125 A
Load Classification
Heating
Lighting - Dwelling Unit
Lighting - Exterior
Other
Power
Receptacle
CKT
1
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39
41
Circuit Description
Lighting
Lighting
Receptacle
Receptacle
Fire Alarm Panel
Receptacle
FACP
IDF Room Power
Trip
20 A
20 A
20 A
20 A
20 A
20 A
20 A
20 A
Heating
30 A
Site Lighting
20 A
Site Lighting
20 A
Site Lighting
20 A
Lighting - Exterior
Gate Power
Gate Power
20 A
20 A
20 A
Gate Power
20 A
Gate Power
20 A
Total...
Total...
3374 VA
105 A
Legend:
Load Classification
Heating
Lighting - Dwelling Unit
Lighting - Exterior
Other
Power
Receptacle
CKT
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
B
1228
A
1305
1800
1800
1800
500
1260
180
180
500
180
500
500
2000
1680
2000
2000
1374
2000
180
1374
1374
180
180
1374
1603
500
500
1603
1050
1680
0
500
500
0
0
500
500
18894 VA
157 A
LIC
E NS ED IN
SS
G
IONA L EN
B
1125
1800
EE
PR
R
100821
0
0
Trip
20 A
20 A
20 A
20 A
20 A
20 A
20 A
20 A
Circuit Description
Lighting
Receptacle
Receptacle
Receptacle
Receptacle
Receptacle
IDF Room Power
MSS-2
30 A
Heating
20 A
20 A
20 A
20 A
20 A
20 A
20 A
20 A
20 A
Receptacle
Receptacle
Receptacle
Power
Power
Other
Spare
Spare
Spare
20 A
Spare
20 A
Spare
CKT
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
PE-SERVICES
F-10841
EXP: 11/30/12
ARCHITECTURE DEMAREST
C ARCHITECTURE DEMAREST, L.P.
ALL RIGHTS RESERVED
DATE
07/16/12
Revision Schedule
No. Date
Description
0 VA
0A
Legend:
Connected Load
4000 VA
2379 VA
750 VA
1810 VA
6948 VA
7560 VA
Demand Factor
100.00%
100.00%
125.00%
100.00%
100.00%
100.00%
Estimated Demand
4000 VA
2379 VA
938 VA
1810 VA
6948 VA
7560 VA
Panel Totals
Total Conn. Load:
Total Est. Demand:
Total Conn.:
Total Est. Demand:
23447 VA
23635 VA
98 A
98 A
Load Classification
Heating
Lighting - Dwelling Unit
Lighting - Exterior
Other
Power
Receptacle
Connected Load
8000 VA
3543 VA
1050 VA
3480 VA
12702 VA
9540 VA
Demand Factor
100.00%
90.04%
125.00%
100.00%
100.00%
100.00%
Estimated Demand
8000 VA
3190 VA
1313 VA
3480 VA
12702 VA
9540 VA
Panel Totals
Total Conn. Load:
Total Est. Demand:
Total Conn.:
Total Est. Demand:
38315 VA
38225 VA
160 A
159 A
JOB NO.
10051
SHEET NO.
COPYRIGHT (C) 2011 ARCHITECTURE DEMAREST, L.P. ALL IDEAS, DESIGNS, ARRANGEMENTS, PLANS, AND SPECIFICATIONS INDICATED OR REPRESENTED BY THIS DRAWING AS INSTRUMENTS OF SERVICE ARE AND SHALL REMAIN THE EXCLUSIVE INTELLECTUAL PROPERTY OF ARCHITECTURE DEMAREST, L.P. AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THIS SPECIFIED PROJECT ONLY. NONE OF SUCH
IDEAS, DESIGN, ARRANGEMENTS OR PLANS SHALL BE USED ON ANY OTHER PROJECT OR EXTENSIONS OF THIS PROJECT OR USED BY OR DISCLOSED TO ANY PERSON, FIRM OR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION FORM AND APPROPRIATE COMPENSATION TO ARCHITECTUREDEMAREST, L.P. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. THE CONTRACTOR
SHALL BEAR SOLE RESPONSIBILITY FOR VERIFYING ALL DIMENSIONS ON THIS PROJECT AND NOTIFIYING ARCHITECTURE DEMAREST, L.P. OF ANY DEVIATIONS. THE CONTRACTOR SHALL BEAR SOLE RESPONSIBILITY FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, CONFIRMING COORDINATION AND FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT. ARCHITECTURE DEMAREST, L.P.
WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT.
E403
ELECTRICAL
TAG
AREA SERVED
TYPE
CFM
E.S.P.
EF-1
EF-2
EF-3
RES. UNIT BATH
CLUB HSE RRR
MAINTENANCE
WALL/CEILING
CENTRIFUGAL
CABINET
50
300
150
1/8"
3/8"
3/8"
HP
VOLT/PHASE
WATTS
FRAC
FRAC
FRAC
120/1
120/1
120/1
60
79
230
MANUFACTURER
MODEL
ACCESSORIES
BROAN
GREENHECK
GREENHECK
(B) 670
LD-75
CSP-A190
4,6,11
4,6,11
4,9,12
ACCESSORIES
1. INSULATED ROOF CURB
2. MOTORIZED DAMPER
3. MOTOR SIDE GUARD
4. GRAVITY BACKDRAFT DAMPER
5. ALUMINUM CONSTRUCTION
6. DISCONNECT SWITCH OR PLUG
7. EXPLOSION PROOF MOTOR
8. VIBRATION ISOLATORS
9. SWITCH BY E.C.
10. CONTROLLED BY THERMOSTAT
11. WIRE TO LIGHT SWITCH BY E.C.
12. PROVIDE GREENHECK ROOF JACK MODEL RJ-6X9
ELECTRIC WALL/CEILING UNIT HEATER
ELECTRICAL
AREA SERVED
UH-1
UH-2
STAIR
MAINTENANCE
TYPE
VOLT/PH
FAN FORCED WALL
UNIT
208/1
208/1
KW
MOUNTING HEIGHT
TO BOTTOM
(FT)
MANUFACTURER
2
SUSPENDED
QMARK
QMARK
4
10
MODEL
AWH4408
MUH108
WEIGHT
ACCESSORIES
-
7,9
1,4,7,9
ALL MECHANICAL WORK SHALL BE DONE PER THE
BUILDING MECHANICAL CODE AND LOCAL
MECHANICAL CODES HAVING JURISDICTION.
B.
MECHANICAL CONTRACTOR SHALL HOLD ALL
DUCTWORK AS TIGHT AS POSSIBLE TO UNDERSIDE
OF STRUCTURE.
C.
MECHANICAL CONTRACTOR SHALL COORDINATE
DUCT ROUTING WITH LIGHTING. NO DUCTWORK
SHALL BE ROUTED OVER OR UNDER ANY LIGHT
FIXTUURES.
D.
ALL ROOFTOP EQUIPMENT SHALL BE INSTALLED A
MINIMUM OF 10'-0" FROM EDGE OF ROOF.
E.
ALL DUCTWORK SHALL BE LINED WITH 1"
ACOUSTICAL LINING UNLESS NOTED OTHERWISE.
DUCT DIMENSIONS SHOWN ARE INSIDE CLEAR.
INCREASE SHEETMETAL SIZES FOR INSULATION.
F.
SPIN-IN FITTINGS WITH AIR SCOPPS SHALL BE
PROVIDED FOR ALL ROUND BRANCH TAPS.
G.
ROUND RIGID SUPPLY, RETURN AND EXHAUST AIR
DUCTWORK SHALL BE EXTERNALLY WRAPPED WITH
1" THICK, 15 LBS DENSITY FOIL-FACED INSULATION.
H.
FLEX CONNECTIONS TO DIFFUSERS ARE TO BE
INSULATED FLEX WITH A MAXIMUM LENGTH OF 6
FEET.
I.
MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE
FOR ALL CONTROL WIRING.
J.
MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE
FOR COORDINATION WITH ELECTRICAL CONTRACTOR
REGARDING THE WIRING OF ALL MECHANICAL
EQUIPMENT.
ACCESSORIES
1. UNIT MOUNTED THERMOSTAT
2. REMOTE THERMOSTAT
3. LOUVER FIN DIFFUSER
4. HANGING BRACKET
5. BAKED ENAMEL FINISH
6. 1" THROWAWAY FILTERS
7. DISCONNECT SWITCH BY ELECTRICAL CONTRACTOR
8. UNIT MOUNTED FAN SPEED SWITCH (3-SPEED)
9. FAN TIMER DELAY RELAY
AIR HANDLING UNIT SCHEDULE
TAG
AREA SERVED
CFM
STATIC
(IN)
AHU-A1,B1,B2
AHU-D1
AHU-3
RESIDENT UNITS
RESIDENT UNITS
CLUB HOUSE
630
1062
2000
0.3
0.4
0.5
ELECTRICAL
EAT º F
OUTPUT
(KW)
5
8
15
MODEL
DB
WB
VOLTAGE/PHASE
MCA
MOCP
75
80
80
63
67
67
230/1
230/1
230/1
27
40
56
30
40
60
MANUFACTURER
GOODMAN
GOODMAN
GOODMAN
FURNACE
ACNT1805
AWUT3008
ARUT60D14
ACCESSORIES
1,2,3,4,6,11,12
1,2,3,4,5,11,12
1,2,3,4,5,10,11,12
K.
ACCESSORIES
1. PROGRAMMABLE THERMOSTAT
2. EXPANSION VALVE
3. DX COOLING COIL
4. DISCONNECT
9. PROVIDE SEALED COMBUSTION AND
12. PROVIDE FLOAT SWITCH IN DRAIN
CONCENTRIC VENT ADAPTOR
PAN FOR SECONDARY CONDENSATE
10. FIELD INSTALL ELCTRIC HKS-15 HEAT KIT
11. SECONDARY CONDENSATE ROUTED ABOVE TUB OR JAN.SINK WITH ESCUTCHEON PLATE
5. VERTICAL
6. HORIZONTAL
7. FILTER SECTION 1" PLEATED
8. HUMIDIFER SECTION
L.
MINI SPLIT SYSTEM SCHEDULE
ELECTRICAL
TAG
MSS-1
MSS-2
AREA SERVED
CLUB HOUSE ELEC
TELECOM RMS
TONS
1.5
0.75
VOLT/PHASE
MCA
MOCP
208/1
120/1
14
14
15
15
INDOOR MODEL
MUY-GE18NA
MU-A09WA
ABOVE FINISHED FLOOR
AIR HANDLER
CEILING DIFFUSER
CUBIC FEET PER MINUTE
CONDENSING UNIT
DIAMETER
DWG
EA
EER
EF
EFF.
E.S.P.
FD
G
HP
DRAWING
EXHAUST AIR
ENERGY EFFICIENCY RATIO
EXHAUST FAN
EFFICIENCY
EXTERNAL STATIC PRESSURE
FIRE DAMPER
GRILLE
HORSE POWER
KW
LD
MBH
OA
OP. WT.
PRESS.
RA
RO
RTU
SA
SG
SR
TYP
UH
KILOWATTS
LINEAR DIFFUSER
THOUSAND BTU/HOUR
OUTSIDE AIR
OPERABLE WEIGHT
PRESSURE
RETURN AIR
ROOF OPENING
ROOFTOP UNIT
SUPPLY AIR
SUPPLY GRILLE
SUPPLY REGISTER
TYPICAL
UNIT HEATER
SUPPLY DIFFUSER
RETURN OR EXHAUST GRILLE
M
MOTORIZED DAMPER
T
THERMOSTAT
ACCESSORIES
MODEL
MITSUBISHI
MITSUBISHI
PROVIDE BALANCE DAMPERS AT ALL BRANCH
DUCTS SERVING DIFFUSERS.
AFF
AH
CD
CFM
CU
DIA
TEMPERATURE SENSOR
OUTDOOR
MANUFACTURER
MECHANICAL CONTRACTOR SHALL INCLUDE IN HIS
PRICE THE COST FOR AN INDEPENDANT AIR
BALANCE CONTRACTOR TO PROVIDE COMPLETE AIR
BALANCE OF SYSTEM AND PROVIDE (6) COPIES TO
THE ARCHITECT AND/OR GENERAL CONTRACTOR
FOR APPROVAL.
MECHANICAL LEGEND:
BALANCING DAMPER
MSY-GE18NA
MS-A09WA
4,5
FIRE DAMPER
DUCT TRANSITION
ACCESSORIES
1. LOW AMBIENT KIT
2. HOT GAS BYPASS
3. DX COOLING COIL
4. DISCONNECT
INDICATES CODED NOTE
5. REFRIGERANT LINE SETS PER MANUFACTURER'S RECOMMENDATIONS
6. LONG LENGTH REFRIGERANT LINE SETS
7. HAIL GUARD
8. CONCRETE PAD
HVAC Legend,
Notes, and
Schedules
TAG
A.
Nacogdoches, TX
GENERAL NOTES:
LUMBERJACK LOFTS
SFA 1411 ASSOCIATES, L.P.
FAN SCHEDULE
TAG
TYPE
NECK
SIZE
(IN)
FRAME
SIZE
(IN)
PATTERN
MANUFACTURER
MODEL
FINISH
REMARKS/NOTES
A
B
C
D
E
F
G
H
J
SUPPLY REGISTER
SUPPLY REGISTER
SUPPLY REGISTER
SUPPLY REGISTER
SUPPLY REGISTER
CEILING DIFFUSER
CEILING DIFFUSER
SUPPLY REGISTER
RETURN GRILLE
NOTED
NOTED
NOTED
NOTED
NOTED
NOTED
NOTED
NOTED
NOTED
NOTED
NOTED
NOTED
NOTED
NOTED
NOTED
NOTED
NOTED
NOTED
LOUVERED
LOUVERED
LOUVERED
LOUVERED
LOUVERED
PLAQUE FACE
PLAQUE FACE
LOUVERED
EGGCRATE
AIRMATE
AIRMATE
AIRMATE
AIRMATE
AIRMATE
TITUS
TITUS
TITUS
TITUS
100
100
E-240-V0
A170FF
A170
OMNI
OMNI
300RS
50F
PER ARCH
PER ARCH
PER ARCH
PER ARCH
PER ARCH
PER ARCH
PER ARCH
PER ARCH
PER ARCH
4
4
4
4
4
4
4
4
4
PERMIT SET
AIR DEVICE SCHEDULE
REMARKS/NOTES
1. OPPOSED BLADE BALANCING DAMPER
2. FIRE BLANKET
3. LAY-IN
4. SURFACE MOUNTED
5. DUCT MOUNTED
CONDENSING UNIT SCHEDULE
1.5
2.5
5
AHU-D1
AHU-3
MOCP
240/1
240/1
240/1
9.1
17.1
32.8
15
30
50
ACCESSORIES
GOODMAN
GOODMAN
GOODMAN
GSX13018
GSX13030
GSX13060
3,4,5,6,8
3,4,5,6,8
3,4,5,6,8
OF TE
TE
X
A
TRENT E BEIGHLE
100821
O
FE
ACCESSORIES
1. LOW AMBIENT KIT
2. HOT GAS BYPASS
3. MATCHING DX COOLING COIL -TXV - R410A
4. DISCONNECT
TA
R
AHU-A1,B1,B2
MCA
MODEL
EE
CU-1
CU-2
CU-3
VOLT/PHASE
MANUFACTURER
S
TONS
PR
FURNACE SERVED
S
ELECTRICAL
TAG
LIC
SS
E NS ED IN
G
IONA L EN
5. STANDARD LENGTH REFRIGERANT LINE SETS ON LOWER FLOOR
6. LONG LENGTH REFRIGERANT LINE SETS ON UPPER FLOORS
7. HAIL GUARD
8. CONCRETE PAD
PE-SERVICES
F-10841
EXP: 11/30/12
ARCHITECTURE DEMAREST
C ARCHITECTURE DEMAREST, L.P.
ALL RIGHTS RESERVED
DATE
07/16/12
Revision Schedule
No. Date
Description
JOB NO.
10051
SHEET NO.
COPYRIGHT (C) 2011 ARCHITECTURE DEMAREST, L.P. ALL IDEAS, DESIGNS, ARRANGEMENTS, PLANS, AND SPECIFICATIONS INDICATED OR REPRESENTED BY THIS DRAWING AS INSTRUMENTS OF SERVICE ARE AND SHALL REMAIN THE EXCLUSIVE INTELLECTUAL PROPERTY OF ARCHITECTURE DEMAREST, L.P. AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THIS SPECIFIED PROJECT ONLY. NONE OF SUCH
IDEAS, DESIGN, ARRANGEMENTS OR PLANS SHALL BE USED ON ANY OTHER PROJECT OR EXTENSIONS OF THIS PROJECT OR USED BY OR DISCLOSED TO ANY PERSON, FIRM OR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION FORM AND APPROPRIATE COMPENSATION TO ARCHITECTUREDEMAREST, L.P. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. THE CONTRACTOR
SHALL BEAR SOLE RESPONSIBILITY FOR VERIFYING ALL DIMENSIONS ON THIS PROJECT AND NOTIFIYING ARCHITECTURE DEMAREST, L.P. OF ANY DEVIATIONS. THE CONTRACTOR SHALL BEAR SOLE RESPONSIBILITY FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, CONFIRMING COORDINATION AND FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT. ARCHITECTURE DEMAREST, L.P.
WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT.
M100
PL2
HP1:31,33
HP1:27,29
PL2
LOW VOLTAGE
PULL BOX
HP1:31,33
PL1
DUMPSTER ENCLOSURE
LOW VOLTAGE
PULL BOX
2
M101
UTILITY XFMR
(PROPOSED
LOCATION)
DUMPSTER ENCLOSURE
DWDW.
A1
REFR.
DW.
DW
WD
WD
WD
A1
DW.
REFR.
B2
B1ALT
D1
J
UP
UP
P.C. CENTER MAIL ROOM
COMMUNITY
SPACE
REF.
PL1
HP1:23,25
LEASING OFFICE
MEN
WORK RM
ASST.MANAGER
MGR.
WOMEN
UP
REF.
INFINITY
EDGE POOL
HP
PL
IDF
FITNESS RM
WD
LOW VOLT
PULL BOX
DWWH
REFR.
B1
DW.
UP
DW.
J
1. REFER TO ENLARGED PLANS FOR ADDITIONAL HVAC EQUIPMENT
AND DUCTWORK ROUTING AND SIZING.
D1
IDF
A1
R.
REF
DW.
DWWH
R.
REF
6
M102
H
DWW IDF
DW
W
DD1-HC
ELEC SERVICE
#5
A1-HC
UTILITY XFMR
B1-HCLOCATION)
(PROPOSED
REFR.
DW
LOW VOLTAGE
PULL BOX
B1
D1
DW
UP
.
EF. R
RW
D
UP
H
DWW
DW.
R.
REF
DW.
R.
REF
DW
DW.
DWWH
BREEZEWAY
.
R
REF
R.
REF
DW.
DW.
R.
REF
WD
ALT
HP3:21,23
PL2
ELEC SERVICE #6
UTILITY XFMR
(PROPOSED LOCATION)
PL1
HP3:21,2
18000 BTUH OUTDOOR UNIT FOR MDF/CCR
HP3:29,31
PL2
TA
OF TE
TE
X
A
S
TRENT E BEIGHLE
PR
R
100821
DUMPSTER ENCLOSURE
O
FE
EE
PL1
HP3:29,31
S
CONTRACTOR TO STENCIL OR PERMANENTLY TAG ALL OUTDOOR
UNITS WITH DWELLING UNIT NUMBER.
5
M102
WD
ALL OUTDOOR UNIT LOCATIONS TO BE COORDINATE WITH
ARCHITECT.
B1
.
DWDW
HVAC Site Plan
B1
PERMIT SET
D1
D1
DW.
B2ALT
REFR.
GENERAL NOTES
PL1
HP3:29,31
REFR.
DWWH
DW.
REFR.
WD
B1
REFR.
D1
Nacogdoches, TX
DWWH
DW.
REFR.
WD
D1
LUMBERJACK LOFTS
SFA 1411 ASSOCIATES, L.P.
7
M102
DW.
WD
PL1
HP1:23,25
REFR.
REFR.
B1
DW.
DWWH
XFMR
OSED LOCATION)
A1
DW.
REFR.
A1
REFR.
DW.
DW
REFR.
DW.
DW
DW
DW.
D1
DW.
REFR.
WD
D1DW.
REFR.
MDF
DW.
B1
REFR.
REFR.
REFR.
B1
DW.
WHWD
DW.
REFR.
DW.
IDF
WHWD
REFR.
(SECOND
FLOOR)
REFR.
DW.
REFR.
ELEC DW.
SERVICE #2
WHWD
ELEC SERVICE #4
DW
WD
REFR.
REFR.
DW.
REFR.
DW.
REFR.
REFR.
WHWD
DW.
ELEC SERVICE
A1 #3A1
WD
REFR.
DW
REFR.
BREEZEWAY
DW.
A1
DW
WHWD
DW.
A1A1 ALT2
WD
ELEC
SERVICE
#1
REFR.
WHWD
D1
D1
WD
DW.
DW.
B1
REFR.
DW.
B1
DW
STAIRS
B1
D1
WD
WD
23,25
IDF
ALT
REFR.
DW.
PL1
A1
REFR.
DW.
4
M102
REFR. ALT
A1DW.
LIC
SS
E NS ED IN
G
IONA L EN
PE-SERVICES
F-10841
EXP: 11/30/12
HP3:29,31
PL2
MSSI-1
HP3:21,23
PL1
LOW VOLTAGE
PULL BOX
PL1
HP3:29,31
IDF / CCR
J
ARCHITECTURE DEMAREST
C ARCHITECTURE DEMAREST, L.P.
ALL RIGHTS RESERVED
PL2
HP3:25,27
18000 BTUH DUCTLESS
SPLIT SYSTEM INDOOR
UNIT IN MDF / CCR
PL2
HP3:25,27
HP3:25,27
PL1
SL1
MSSI-1
HP3:25,27
PL1
HP3:25,27
PL1
SL1
SL1
SL1 MB1:15
JH
H
J
MAINTANCE BUILDING
DATE
07/16/12
Revision Schedule
No. Date
Description
SL1
SL1 MB1:13
BASKETBALL COURT
LIGHTING CONTROL
JOB NO.
AREA A-1ST FLOOR MDF/CCR PART
PLAN
2
1/4" = 1'-0"
10051
1
Mechanical Site Plan
1" = 30'-0"
COPYRIGHT (C) 2011 ARCHITECTURE DEMAREST, L.P. ALL IDEAS, DESIGNS, ARRANGEMENTS, PLANS, AND SPECIFICATIONS INDICATED OR REPRESENTED BY THIS DRAWING AS INSTRUMENTS OF SERVICE ARE AND SHALL REMAIN THE EXCLUSIVE INTELLECTUAL PROPERTY OF ARCHITECTURE DEMAREST, L.P. AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THIS SPECIFIED PROJECT ONLY. NONE OF SUCH
IDEAS, DESIGN, ARRANGEMENTS OR PLANS SHALL BE USED ON ANY OTHER PROJECT OR EXTENSIONS OF THIS PROJECT OR USED BY OR DISCLOSED TO ANY PERSON, FIRM OR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION FORM AND APPROPRIATE COMPENSATION TO ARCHITECTUREDEMAREST, L.P. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. THE CONTRACTOR
SHALL BEAR SOLE RESPONSIBILITY FOR VERIFYING ALL DIMENSIONS ON THIS PROJECT AND NOTIFIYING ARCHITECTURE DEMAREST, L.P. OF ANY DEVIATIONS. THE CONTRACTOR SHALL BEAR SOLE RESPONSIBILITY FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, CONFIRMING COORDINATION AND FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT. ARCHITECTURE DEMAREST, L.P.
WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT.
SHEET NO.
M101
BREEZEWAY
MSSI-2
MSSI-2
7,000 BTUH DUCTLESS
SPLIT SYSTEM FOR
MEDIA CLOSET ONLY
MSS-2
HP3:16
BREEZEWAY
STAIRS
7,000BTUH DUCTLESS
SPLIT SYSTEM
FIRST FLOOR BCR
STAIRS
7000BTUH DUCTLESS SPLIT
SYSTEM OUTDOOR UNIT ON
GRADE, INDOOR UNIT IN
2ND FLOOR BCR CLOSET
MSS-2
HP1:20
A1-HC
UH
1
MSSI-2
PARTIAL STAIR / BCR PLAN
1/4" = 1'-0"
UH
1
MOUNT UNDER
STAIR
MSS-2
HP3:32
UP
3
Stair 7, 8 & 116
1/4" = 1'-0"
Partial Mechanical - Level 1 Area B1 Media
Closet
5
1/4" = 1'-0"
6
AREA B-1ST FLOOR BCR
1/4" = 1'-0"
CU
2
CU
1
CU
1
CU
2
CU
1
CU
2
CU
1
CU
1
CU
1
CU
1
CU
1
CU
1
MSSI-1
PERMIT SET
Stair 5 & 6
1/4" = 1'-0"
CU
1
A1
DW.
REFR.
ALT
CU
1
REFR.
WH W D
REFR.
DW
DW
REFR.
REFR.
WH W D
REFR.
CU
1
CU
2
DW.
WD
B2
B1ALT
R
WD
WD
A1
CU
2
DW
CU
1
DW.
REFR.
CU
2
D1
DW.
REFR.
D1
A1
100821
D1
FE
O
B1
A1
A
TRENT E BEIGHLE
PR
B1
A1
DW.
OF TE
TE
X
LIC
SS
E NS ED IN
G
IONA L EN
PE-SERVICES
F-10841
EXP: 11/30/12
D W WH
D1
DW.
REFR.
REFR.
DW.
DW.
DW.
DW.
REFR.
DW.
REFR.
DW.
REFR.
DW.
WH W D
UP
DW
3
M102
STAIRS
REFR.
REFR.
DW
WH W D
DW
STAIRS
S
BREEZEWAY
TA
S
REFR.
MSSI-1
A1
WD
WH W D
REFR.
DW.
REFR.
DW.
WD
REFR.
DW.
WD
DW.
DW
A1
REFR.
DW.
DW.
WD
REFR.
WH W D
DW.
WD
DW.
A1
A1 ALT2
REFR.
DW.
A1
B1ALT
A1
REFR.
DW.
D1
DW
D1
REFR.
DW.
B1
DW
B1
REFR.
DW.
D1
ALT
WD
REFR.
DW.
A1
WD
CU
2
CU
1
CU
1
CU
1
CU
1
CU
1
CU
1
CU
1
B1
ARCHITECTURE DEMAREST
DW.
WD
REFR.
REFR.
4" CONCRETE PAD.
TYPICAL.
DW.
2
Partial Mechanical - Level 1 Area A1 Media
Closet
4
1/4" = 1'-0"
EE
7
Nacogdoches, TX
MOUNT UNDER STAIR
LUMBERJACK LOFTS
SFA 1411 ASSOCIATES, L.P.
MSSI-2
7,000BTUH DUCTLESS
SPLIT SYSTEM FOR
MEDIA CLOSET ONLY
HVAC Plan Section A
MSS-2
HP1:17
C ARCHITECTURE DEMAREST, L.P.
ALL RIGHTS RESERVED
D1
CU
2
DATE
07/16/12
CU
1
FITNESS RM
DW.
CU-3
3
REFR.
B1
Revision Schedule
No. Date
Description
D W WH
WD
UP
STAIRS
P.C. CENTER
2
M102
MAIL ROOM
JOB NO.
1
HVAC - First Floor Section A
1/16" = 1'-0"
10051
SHEET NO.
COPYRIGHT (C) 2011 ARCHITECTURE DEMAREST, L.P. ALL IDEAS, DESIGNS, ARRANGEMENTS, PLANS, AND SPECIFICATIONS INDICATED OR REPRESENTED BY THIS DRAWING AS INSTRUMENTS OF SERVICE ARE AND SHALL REMAIN THE EXCLUSIVE INTELLECTUAL PROPERTY OF ARCHITECTURE DEMAREST, L.P. AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THIS SPECIFIED PROJECT ONLY. NONE OF SUCH
IDEAS, DESIGN, ARRANGEMENTS OR PLANS SHALL BE USED ON ANY OTHER PROJECT OR EXTENSIONS OF THIS PROJECT OR USED BY OR DISCLOSED TO ANY PERSON, FIRM OR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION FORM AND APPROPRIATE COMPENSATION TO ARCHITECTUREDEMAREST, L.P. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. THE CONTRACTOR
SHALL BEAR SOLE RESPONSIBILITY FOR VERIFYING ALL DIMENSIONS ON THIS PROJECT AND NOTIFIYING ARCHITECTURE DEMAREST, L.P. OF ANY DEVIATIONS. THE CONTRACTOR SHALL BEAR SOLE RESPONSIBILITY FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, CONFIRMING COORDINATION AND FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT. ARCHITECTURE DEMAREST, L.P.
WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT.
M102
MAIL ROOM
REF.
MEN
WORK RM
MANAGER
ASST. MGR.
REF.
WOMEN
STAIRS
B1
WD
D W WH
DW.
CU
1
REFR.
UP
CU
1
CU
2
D1
H
DW W
DW
R.
REF
R.
REF
DW.
DW
STAIRS
UP
FR.
WE.
DR
A1
WH
DW.
DW
R.
REF
DW.
DW
R.
REF
D1-HC
DW
B1-HC
A
DW.
R
100821
R.
REF
DW
R.
REF
OF TE
TE
X
TRENT E BEIGHLE
WH
DW
FE
O
WD
WD
R.
REF
H
DW W
TA
PR
DW.
DW.
D1
R.
REF
BREEZEWAY
S
DW.
B1
DW.
CU
2
S
DW
REFR.
CU
1
D1
EE
REFR.
4" CONCRETE PAD.
TYPICAL.
B1
PERMIT SET
B2ALT
CU
1
CU
2
CU
2
D W WH
DW.
CU
2
REFR.
B1
DW.
WD
CU
1
REFR.
D1
HVAC Plan Section B
P.C. CENTER
FITNESS RM
Nacogdoches, TX
UP
STAIRS
LUMBERJACK LOFTS
SFA 1411 ASSOCIATES, L.P.
H
CU
1
EFR.
DW.
CU-3
3
LIC
SS
E NS ED IN
G
IONA L EN
DW
A1-HC
PE-SERVICES
F-10841
EXP: 11/30/12
CU
1
REFR.
DW
B1
D1
CU
1
ALT
CU
1
ARCHITECTURE DEMAREST
C ARCHITECTURE DEMAREST, L.P.
ALL RIGHTS RESERVED
DATE
07/16/12
CU
2
CU
1
Revision Schedule
No. Date
Description
JOB NO.
10051
1
HVAC - First Floor Section B
1/16" = 1'-0"
COPYRIGHT (C) 2011 ARCHITECTURE DEMAREST, L.P. ALL IDEAS, DESIGNS, ARRANGEMENTS, PLANS, AND SPECIFICATIONS INDICATED OR REPRESENTED BY THIS DRAWING AS INSTRUMENTS OF SERVICE ARE AND SHALL REMAIN THE EXCLUSIVE INTELLECTUAL PROPERTY OF ARCHITECTURE DEMAREST, L.P. AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THIS SPECIFIED PROJECT ONLY. NONE OF SUCH
IDEAS, DESIGN, ARRANGEMENTS OR PLANS SHALL BE USED ON ANY OTHER PROJECT OR EXTENSIONS OF THIS PROJECT OR USED BY OR DISCLOSED TO ANY PERSON, FIRM OR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION FORM AND APPROPRIATE COMPENSATION TO ARCHITECTUREDEMAREST, L.P. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. THE CONTRACTOR
SHALL BEAR SOLE RESPONSIBILITY FOR VERIFYING ALL DIMENSIONS ON THIS PROJECT AND NOTIFIYING ARCHITECTURE DEMAREST, L.P. OF ANY DEVIATIONS. THE CONTRACTOR SHALL BEAR SOLE RESPONSIBILITY FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, CONFIRMING COORDINATION AND FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT. ARCHITECTURE DEMAREST, L.P.
WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT.
SHEET NO.
M103
ARCHITECTURAL LOUVER.
REFER TO ARCHITECTURAL
PLANS FOR MORE
INFORAMTION.
ARCHITECTURAL LOUVER.
REFER TO ARCHITECTURAL
PLANS FOR MORE
INFORAMTION.
UH
UH-2
ROUTE CONDENSATE DOWN
ALONG OUT SIDE OF WALL
TO 6" ABOVE GRADE.
ROUTE EXHAUST UP THROUGH
ROOF TO EXHAUST CAP
3
GREENHECK SIDEWALL
EXHAUST FAN WITH LOUVER
EQUAL TO S1-8-440-E.
MOUNT FAN 6" BELOW ROOF.
EF
EF-
8"ø
GREENHECK SIDEWALL
EXHAUST FAN WITH LOUVER
EQUAL TO S1-8-440-E.
MOUNT FAN 6" BELOW ROOF.
GREENHECK SIDEWALL
EXHAUST FAN WITH LOUVER
EQUAL TO S1-8-440-E.
MOUNT FAN 6" BELOW ROOF.
LUMBERJACK LOFTS
SFA 1411 ASSOCIATES, L.P.
(SUSPENDED)
(SUSPENDED)
PROVIDE PTAC UNIT EQUAL
TO FREDRICH MODEL
#CP18N30.
Pool Equipment Room HVAC Plan
1/4" = 1'-0"
2
HVAC Plan - Maintenance Building
1/4" = 1'-0"
Nacogdoches, TX
ARCHITECTURAL LOUVER.
REFER TO ARCHITECTURAL
PLANS FOR MORE
INFORAMTION.
DW.
LOW PROFILE OUTDOOR AIR
INTAKE ON ROOF CURB
SLOPE TO MATCH ROOF PITCH
J- 240
24x24 - 22x22 Neck
TYP. (3)
16"x12"
F- 300
24x24 - 8 Neck
16"x20"
12"x12"
G- 240
12x12 - 8 Neck
TYP. (4)
ELEC/MDF
8"ø
H- 240
16x6
TYP. (2)
AHU (5) TON SPLIT SYSTEM ABOVE CEILING
WITH SAFETY PAN, PIPE PAN AND OVERFLOW
3
DRAINS TO OPEN SIGHT
20"x16"
F- 200
24x24 - 8 Neck
16"x20"
16"x20"
8"ø
8"ø
8"ø
SS
E NS ED IN
G
IONA L EN
PE-SERVICES
F-10841
EXP: 11/30/12
6"ø
F- 100
24x24 - 6 Neck
TYP. (2)
F- 250
24x24 - 8 Neck
WOMEN
G- 100
12x12 - 6 Neck
J- 150
TYP. (2)
24x24 - 12x12 Neck
TYP. (2)
F- 200
24x24 - 8 Neck
F- 150
24x24 - 8 Neck
MANAGER
ARCHITECTURE DEMAREST
ASST. MGR.
STAIRS
WORK RM
C ARCHITECTURE DEMAREST, L.P.
ALL RIGHTS RESERVED
PROVIDE 14x8 TITUS MODEL 50F
EGGCRATE GRILLE AT CEILING OF OFFICE
AND TITUS 350FL TRANSFER GRILLE ON
WALL ABOVE OFFICE CEILING. MOUNT
TRANSFER GRILLE 6" BELOW CEILING FOR
LOBBY. TYPICAL FOR ALL 3 OFFICE
LOCATIONS.
DW.
UP
1
R
FE
LIC
H- 230
16x6
TYP. (4)
8"ø
8"ø
REF.
8"ø
8"ø
MEN
REF.
8"ø
8"ø
8"ø
8"ø
G- 240
12x12 - 8 Neck
TYP. (2)
O
300 CFM EXAHUST FAN (EF-2) ON ROOF CURB
SLOPE TO MATCH ROOF PITCH. BACKDRAFT
DAMPER IN TRAY
A
TRENT E BEIGHLE
PR
COMMUNITY
SPACE
OF TE
TE
X
100821
J- 1460
24x24 - 22x22 Neck
G- 260
12x12 - 8 Neck
TYP. (4)
H- 260
16x6
TYP. (3)
8"ø
8"ø
14"x22"
P.C. CENTER
TA
S
S
16"x20"
8"ø
14"x14"
EE
MOUNT 20"x16" RETURN
GRILLE 6" BELOW CEILING ON
WALL. RETURN GRILLE SHALL
EQUAL TITUS 350FL.
MOUNT OUTDOOR AIR DUCT AS HIGH AS
POSSIBILE ALONG CEILING JOIST. ROUTE
10"x10" DUCT TO RETURN AIR PLENUM BOX
STAIRS
FOR EACH UNIT.
8"ø
FITNESS RM
75CFM CEILING MTD. EXH FAN
MAIL ROOM
RUNS CONTINUOUSLY. ROUTE
UP
DUCT UP THROUGH ROOF TO
ROOF JACK.
PERMIT SET
WH
7000 BTUH DUCTLESS SPLIT
SYSTEM SERVING BCR ROOM
HVAC Plan Clubhouse Area
& Maintenance
Building
W
REFR.
B1
HVAC Plan - Clubhouse Area Enlarged
1/8" = 1'-0"
DATE
07/16/12
Revision Schedule
No. Date
Description
JOB NO.
10051
SHEET NO.
COPYRIGHT (C) 2011 ARCHITECTURE DEMAREST, L.P. ALL IDEAS, DESIGNS, ARRANGEMENTS, PLANS, AND SPECIFICATIONS INDICATED OR REPRESENTED BY THIS DRAWING AS INSTRUMENTS OF SERVICE ARE AND SHALL REMAIN THE EXCLUSIVE INTELLECTUAL PROPERTY OF ARCHITECTURE DEMAREST, L.P. AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THIS SPECIFIED PROJECT ONLY. NONE OF SUCH
IDEAS, DESIGN, ARRANGEMENTS OR PLANS SHALL BE USED ON ANY OTHER PROJECT OR EXTENSIONS OF THIS PROJECT OR USED BY OR DISCLOSED TO ANY PERSON, FIRM OR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION FORM AND APPROPRIATE COMPENSATION TO ARCHITECTUREDEMAREST, L.P. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. THE CONTRACTOR
SHALL BEAR SOLE RESPONSIBILITY FOR VERIFYING ALL DIMENSIONS ON THIS PROJECT AND NOTIFIYING ARCHITECTURE DEMAREST, L.P. OF ANY DEVIATIONS. THE CONTRACTOR SHALL BEAR SOLE RESPONSIBILITY FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, CONFIRMING COORDINATION AND FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT. ARCHITECTURE DEMAREST, L.P.
WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT.
M104
1
1
4"ø
9"ø
9"ø
5. ROUTE TOILET AND DYER EXHAUST THROUGH 18" OPEN WEB
STRUCTURE.
6. ALL WALL CAPS SHALL HAVE BACKDRAFT DAMPERS. TOILET EXHAUST
SHALL ALSO INCLUDE INSECT SCREENS.
4"ø
REFR.
9. 1ST FLOOR DRYER AND TOILET EXHUAST ROUTE UP TO 2ND FLOOR
STUCTURE. UPPER LEVEL DRYER AND EXHAUST DUCT SHALL ROUTE
DOWN TO DWELLING UNIT FLOOR STRUCTURE BELOW.
UNIT A-1
DRYER VENTING COMPLIANCE
4
D
7'-6"
APPROXIMATE DUCT LENGTH
37'-0"
4"Ø DUCT SHALL BE USED
5
B- 20
8x4
APPROXIMATE DUCT LENGTH
4"Ø DUCT SHALL BE USED
5
Unit A-1, A-1 Alt, and A-1 Alt-2 - HVAC
1/4" = 1'-0"
2
Unit A-1-HC - HVAC
1/4" = 1'-0"
UNIT B-2
DRYER VENTING COMPLIANCE
UNIT B-1
24'-6"
6'-0"
7'-6"
38'-0"
DRYER VENTING COMPLIANCE
27'-6"
HORIZONTAL RUN
VERTICAL
(1.5) 90 DEGREE ELBOWS
6'-0"
7'-6"
41'-0"
APPROXIMATE DUCT LENGTH
HORIZONTAL RUN
VERTICAL
(1.5) 90 DEGREE ELBOWS
APPROXIMATE DUCT LENGTH
4"Ø DUCT SHALL BE USED
PERMIT SET
1
4"Ø DUCT SHALL BE USED
5
7"ø
FD
8"ø
7"ø
W
4"ø
8"ø
8"ø
A- 30
8x6
C- 125
12x6
100821
FE
6
8"
ø
LIC
SS
E NS ED IN
G
IONA L EN
PE-SERVICES
F-10841
EXP: 11/30/12
2
5"ø
W
4"ø
DW.
A- 30
8x6
A
C- 180
14x6
4"ø
AH
B1
6"
ø
C- 125
12x6
OF TE
TE
X
TRENT E BEIGHLE
O
EF
1
7"ø
TA
S
C- 180
14x6
D- 500
24x12
D- 24x12
D- 24x12
A- 30
8x6
T
FD
3 1.3 SF
PR
C- 125
12x6
AH
B1
A- 30
8x6
C- 100
10x6
C- 125
12x6
DW
C- 125
12x6
EF
1
C- 100
10x6
ø
8"
C- 180
14x6
ø
6"
EF
1
5"ø
EF
1
4
6"ø
D
5
REFR.
S
B- 20
8x4
3 1.3 SF
A- 30
8x6
AH
B2
DW.
B- 20
8x4
REFR.
W
2
D
2
4"ø
1
R
4
HORIZONTAL RUN
VERTICAL
(1.5) 90 DEGREE ELBOWS
EE
23'-6"
6'-0"
HVAC Unit Plans
D
B- 20
8x4
8. GENERAL CONTRACTOR TO COORDINATE SUPPLY DUCT PLENUM FOR
APARTMENT FAN COIL UNITS WITH STRUCTURAL DRAWINGS (BY
OTHERS) PRIOR TO INSTALLATION TO AVOID DUCT EXTENSIONS INTO
STRUCTURE CONFLICTS.
W
W
4"ø
C- 100
10x6
DW.
C- 100
10x6
7. GENERAL CONTRACTOR SHALL COORDINATE WASHER BOX, ELECTRICAL
RECEPTICAL, DRYER VENT BOX, ETC. BEHIND SIDE BY SIDE LAUNDRY
EQUIPMENT.
DW
A- 30
8x6
REFR.
AH
A1
6"ø
5"ø
D- 500
24x12
AH
A1
D- 24x12
6"ø
37'-0"
4. MAINTAIN A MINIMUM OF 3'-0" FROM EXHAUST TO ALL APERABLE
WINDOWS AND DOORS.
6 LAUNDRY DRYER MAKE UP AIR THROUGH TRANSFER DUCT WITH
TYPE 'E' GRILLES ON EACH SIDE OF WALL PER IMC.
Nacogdoches, TX
4"ø
4"ø
7'-6"
3. CONTRACTOR SHALL COORDINATE DUCTWORK ROUTING THROUGH
18" DEEP OPEN WEB STRUCTURE AND ATTIC SPACE TO AVOID
STUCTURAL AND ARCHITECTURAL CONFLICTS.
5 RECIRCULATING KITCHEN RANGE HOOD
5"ø
7"ø
HORIZONTAL RUN
VERTICAL
(1.5) 90 DEGREE ELBOWS
2. COORDINATE ALL WALL CAP VENT LOCATIONS WITH ARCHITECTURAL
STRUCTURAL DRAWINGS.
7"ø
A- 30
8x6
23'-6"
6'-0"
1. KITCHEN RANGE VENT HOOD (BY OTHERS) IS RECIRCULATING AND
SHLL BE PROVIDED WITH AN INTEGRALBACK DRAFT DAMPER.
4 UNDERCUT DOORS 1" FOR MINIMUM 100 SQUARE INCHES FREE AREA
FOR DRYER MAKE-UP AIR PER 2006 INTERNATIONAL CODE.
FD
UNIT A-1
DRYER VENTING COMPLIANCE
1 DRYER EXHAUST VENT ROUTED TO EXTERIOR WALL CAP.
3 KNOCKOUT IN WALL FOR RETURN AIR. REFER TO PLANS FOR
MINIMUM FREE AREA REQUIRED IN FURR DOWN PLENUM SPACE.
C- 150
12x6
EF
1
GENERAL NOTES
2 4" DIA. BATH EXHAUST ROUTED TO EXTERIOR WALL CAP.
C- 230
14x8
C- 230
14x8
C- 150
12x6
KEYNOTES
LUMBERJACK LOFTS
SFA 1411 ASSOCIATES, L.P.
2
2
4
UNIT B-1
6'-0"
7'-6"
38'-0"
HORIZONTAL RUN
5
8"ø
REFR.
VERTICAL
(1.5) 90 DEGREE ELBOWS
C- 180
12x6
4"ø
24'-6"
B- 20
8x4
B- 20
8x4
B- 20
8x4
EF
1
2
7"ø
A- 30
8x6
1
EF
1
2
Unit B-1 and B-1 Alt. - HVAC
1/4" = 1'-0"
C ARCHITECTURE DEMAREST, L.P.
ALL RIGHTS RESERVED
1
4"Ø DUCT SHALL BE USED
3
ø
ARCHITECTURE DEMAREST
2
APPROXIMATE DUCT LENGTH
4"
4"ø
DRYER VENTING COMPLIANCE
D
6"ø
C- 100
10x6
4
Unit B-1-HC - HVAC
1/4" = 1'-0"
5
DATE
07/16/12
Revision Schedule
No. Date
Description
Unit B-2 - HVAC
1/4" = 1'-0"
JOB NO.
10051
SHEET NO.
COPYRIGHT (C) 2011 ARCHITECTURE DEMAREST, L.P. ALL IDEAS, DESIGNS, ARRANGEMENTS, PLANS, AND SPECIFICATIONS INDICATED OR REPRESENTED BY THIS DRAWING AS INSTRUMENTS OF SERVICE ARE AND SHALL REMAIN THE EXCLUSIVE INTELLECTUAL PROPERTY OF ARCHITECTURE DEMAREST, L.P. AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THIS SPECIFIED PROJECT ONLY. NONE OF SUCH
IDEAS, DESIGN, ARRANGEMENTS OR PLANS SHALL BE USED ON ANY OTHER PROJECT OR EXTENSIONS OF THIS PROJECT OR USED BY OR DISCLOSED TO ANY PERSON, FIRM OR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION FORM AND APPROPRIATE COMPENSATION TO ARCHITECTUREDEMAREST, L.P. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. THE CONTRACTOR
SHALL BEAR SOLE RESPONSIBILITY FOR VERIFYING ALL DIMENSIONS ON THIS PROJECT AND NOTIFIYING ARCHITECTURE DEMAREST, L.P. OF ANY DEVIATIONS. THE CONTRACTOR SHALL BEAR SOLE RESPONSIBILITY FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, CONFIRMING COORDINATION AND FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT. ARCHITECTURE DEMAREST, L.P.
WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT.
M200
2
2
1
KEYNOTES
UP
2
1 DRYER EXHAUST VENT ROUTED TO EXTERIOR WALL CAP.
UP
2 4" DIA. BATH EXHAUST ROUTED TO EXTERIOR WALL CAP.
4"ø
4"ø
4"ø
3 KNOCKOUT IN WALL FOR RETURN AIR. REFER TO PLANS FOR
MINIMUM FREE AREA REQUIRED IN FURR DOWN PLENUM SPACE.
4
4"ø
P202
6 LAUNDRY DRYER MAKE UP AIR THROUGH TRANSFER DUCT
WITH TYPE 'E' GRILLES ON EACH SIDE OF WALL PER IMC.
7 DUCT UP TO FLOOR REGISTIER ON UPPER FLOOR.
4"ø
A- 20
8x6
18"x6"
4"ø
18"x6"
4"ø
GENERAL NOTES
A- 20
8x6
2
2. COORDINATE ALL WALL CAP VENT LOCATIONS WITH ARCHITECTURAL
STRUCTURAL DRAWINGS.
7
EF
1
B- 20
8x4
C- 100
10x6
5
5. ROUTE TOILET AND DYER EXHAUST THROUGH 18" OPEN WEB
STRUCTURE.
6. ALL WALL CAPS SHALL HAVE BACKDRAFT DAMPERS. TOILET EXHAUST
SHALL ALSO INCLUDE INSECT SCREENS.
4"ø
3
DW.
EF
1
3
C- 125
12x6
Unit B-3 Lower Level - HVAC
1
1/4" = 1'-0"
7. GENERAL CONTRACTOR SHALL COORDINATE WASHER BOX, ELECTRICAL
RECEPTICAL, DRYER VENT BOX, ETC. BEHIND SIDE BY SIDE LAUNDRY
EQUIPMENT.
Unit B-3 Upper Level - HVAC
2
1/4" = 1'-0"
UNIT B-2
DRYER VENTING COMPLIANCE
C- 100
10x6
5
REFR.
A- 30
8x6 3
27'-6"
6'-0"
AH
B2
7'-6"
41'-0"
8. GENERAL CONTRACTOR TO COORDINATE SUPPLY DUCT PLENUM FOR
APARTMENT FAN COIL UNITS WITH STRUCTURAL DRAWINGS (BY
OTHERS) PRIOR TO INSTALLATION TO AVOID DUCT EXTENSIONS INTO
STRUCTURE CONFLICTS.
UNIT B-3
DRYER VENTING COMPLIANCE
HORIZONTAL RUN
VERTICAL
(1.5) 90 DEGREE ELBOWS
23'-6"
6'-0"
APPROXIMATE DUCT LENGTH
37'-0"
7'-6"
4"Ø DUCT SHALL BE USED
5
4. MAINTAIN A MINIMUM OF 3'-0" FROM EXHAUST TO ALL APERABLE
WINDOWS AND DOORS.
9. 1ST FLOOR DRYER AND TOILET EXHUAST ROUTE UP TO 2ND FLOOR
STUCTURE. UPPER LEVEL DRYER AND EXHAUST DUCT SHALL ROUTE
DOWN TO DWELLING UNIT FLOOR STRUCTURE BELOW.
HORIZONTAL RUN
VERTICAL
(1.5) 90 DEGREE ELBOWS
APPROXIMATE DUCT LENGTH
4"Ø DUCT SHALL BE USED
Unit B-2 Alt - HVAC
1/4" = 1'-0"
2
2
AH
D1
B- 20
8x4
2
8"ø
5
REFR.
D
B- 20
8x4
WH
WH
W
8"ø
7"ø
DW.
4"ø
4"ø
C- 125
12x6
7"ø
7"ø
4
WH
R
9"ø
C- 125
12x6
PE-SERVICES
F-10841
EXP: 11/30/12
ARCHITECTURE DEMAREST
C ARCHITECTURE DEMAREST, L.P.
ALL RIGHTS RESERVED
4"ø
DATE
8"ø
UNIT D-1
8"ø
B- 20
8x4
4"ø
A- 30
8x6
E NS ED IN
G
IONA L EN
C- 125
12x6
18"x10"
RA (BELOW)
4"ø
C- 125
12x6
4"ø
EF
1
SS
4"ø
7"ø
9"ø
C- 125
12x6
ø
4"
A- 30
8x6
EF
1
ø
4"
EF
1
EF
1
C- 250
14x8
A- 30
8x6
A- 30
8x6
A- 30
8x6
A- 30
8x6
EF
1
FE
7"ø
C- 250
14x8
EF
1
EF
1
C- 125
12x6
A- 30
8x6
EF
1
7"ø
ø
4"
ø
8"
DW
LIC
ø
8"
C- 125
12x6
A- 30
8x6
O
C- 125
12x6
A
100821
PR
C- 125
12x6
OF TE
TE
X
TRENT E BEIGHLE
C- 125
12x6
4"
ø
TA
S
ø
4"
4"ø
7"ø
S
5"ø
4
18"x10"
1
EE
W
C- 180
12x6
B- 20
8x4
D- 620
24x12
3. CONTRACTOR SHALL COORDINATE DUCTWORK ROUTING THROUGH
18" DEEP OPEN WEB STRUCTURE AND ATTIC SPACE TO AVOID
STUCTURAL AND ARCHITECTURAL CONFLICTS.
PERMIT SET
D
EF
1
4
6
1. KITCHEN RANGE VENT HOOD (BY OTHERS) IS RECIRCULATING AND
SHLL BE PROVIDED WITH AN INTEGRALBACK DRAFT DAMPER.
Nacogdoches, TX
18"x8"
B- 20
8x4
LUMBERJACK LOFTS
SFA 1411 ASSOCIATES, L.P.
AH
A1
C- 150
10x6
C- 180
12x6
5 RECIRCULATING KITCHEN RANGE HOOD
C- 150
12x6
C- 150
12x6
1
A- 30
8x6
4
P202
HVAC Unit Plans
EF
1
4 UNDERCUT DOORS 1" FOR MINIMUM 100 SQUARE INCHES FREE AREA
FOR DRYER MAKE-UP AIR PER 2006 INTERNATIONAL CODE.
07/16/12
DRYER VENTING COMPLIANCE
W
REFR.
D
5
AH
D1
B- 20
8x4
26'-0"
6'-0"
7'-6"
39'-6"
HORIZONTAL RUN
VERTICAL
(1.5) 90 DEGREE ELBOWS
2
APPROXIMATE DUCT LENGTH
1
2
Revision Schedule
No. Date
Description
2
4"Ø DUCT SHALL BE USED
3
Unit D-1 - HVAC
1/4" = 1'-0"
4
Unit D-1-HC - HVAC
1/4" = 1'-0"
JOB NO.
10051
SHEET NO.
COPYRIGHT (C) 2011 ARCHITECTURE DEMAREST, L.P. ALL IDEAS, DESIGNS, ARRANGEMENTS, PLANS, AND SPECIFICATIONS INDICATED OR REPRESENTED BY THIS DRAWING AS INSTRUMENTS OF SERVICE ARE AND SHALL REMAIN THE EXCLUSIVE INTELLECTUAL PROPERTY OF ARCHITECTURE DEMAREST, L.P. AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THIS SPECIFIED PROJECT ONLY. NONE OF SUCH
IDEAS, DESIGN, ARRANGEMENTS OR PLANS SHALL BE USED ON ANY OTHER PROJECT OR EXTENSIONS OF THIS PROJECT OR USED BY OR DISCLOSED TO ANY PERSON, FIRM OR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION FORM AND APPROPRIATE COMPENSATION TO ARCHITECTUREDEMAREST, L.P. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. THE CONTRACTOR
SHALL BEAR SOLE RESPONSIBILITY FOR VERIFYING ALL DIMENSIONS ON THIS PROJECT AND NOTIFIYING ARCHITECTURE DEMAREST, L.P. OF ANY DEVIATIONS. THE CONTRACTOR SHALL BEAR SOLE RESPONSIBILITY FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, CONFIRMING COORDINATION AND FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT. ARCHITECTURE DEMAREST, L.P.
WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT.
M201
NOTE 1.
MAXIMUM HANGER
SPACING 5'-0" ON
HORIZONTAL RUNS
1" STRAP AND
CEILING HANGER
WIRE ATTACHED
TO JOIST ABOVE
SPIN-IN COLLAR WITH DAMPER
MAIN SUPPLY DUCT 2 IN. THICK DUCT WRAP,
1.0PCF, R-6.0 INSTALLED, FSK FOIL FACED
JACKET, KNAUF, OWENS CORNING OR EQUAL
NOTE 2.
NOTE 3.
ROUND FLEXIBLE DUCT SAME SIZE AS DIFFUSER
NECK (6'-0" MAX. LENGTH)
UL CLASS 1 INSULATED DUCT MATERIAL,
THERMAFLEX # M-KE 2" INSULATED, R-6.0
INSULATED FLEX DUCT
NOTE 1.
3" EXHAUST VENT UP THRU TOP
PLATE AND INTO TRUSS SYSTEM.
TRANSITION IN TRUSS SYSTEM
FROM A 3" TO DUCT SIZE SHOWN
ON PLANS.
RIGID DUCT
NOTE 2.
EXHAUST FAN
IN WALL
NOTE 3.
L.P. VERTICAL MOUNTING
INTERIOR PARTITION WALL
HAVING ADEQUATE DEPTH FOR
INSTALLATION OF WALL FAN.
4 INCH LONG DUCT COLLAR TYP. FOR
ALL CONNECTIONS TO CEILING
DIFFUSERS
INSULATE TOP OF DIFFUSER AND
REGISTER (TYP.)
1. METHOD OF INSTALLATION FOR AIRTIGHT SEAL WILL BE TYPICAL
FOR ALL FLEX CONNECTIONS TO AIR DISTRIBUTION DEVICES
2. INSULATE TOP OF DIFFUSER ABOVE CEILING AS SCHEDULED.
2
USE SLIP JOINT CONN. AS RECOMMENDED BY SMACNA (TYP. ALL FIRE DAMPERS)
3" EXHAUST VENT DOWN THRU BOTTOM
PLATE AND INTO TRUSS SYSTEM.
TRANSITION IN TRUSS SYSTEM FROM A 3:
TO A DUCT SIZE SHOWN ON PLANS.
FINISHED FLOOR
3.
4.
**WHERE ROUTED TO WALL CAP**
MOUNT TOP OF FAN 12" BELOW FINISHED CEILING
REFER TO ARCHITECTURAL DWGS. FOR
CEILING TYPE
CEILING DIFFUSER SEE SCHEDULE FOR MODEL #.
2. COLLAR GAUGES SHALL CONFORM TO SMACNA STDS. (TYP. ALL FIRE DAMPERS)
BOTTOM PLATE SHALL BE
CUT AND FIRESTOPPED
USING APPROVED FIRE
STOP MATERIAL
MOUNT TOP OF FAN 12" BELOW FINISHED CEILING
NOTE:
FINISHED FLOOR
Exhaust Fan Ducting Detail
12" = 1'-0"
4
Top Level Exhaust Fan Ducting Detail
12" = 1'-0"
5
PROVIDE AN ACCESS DOOR IN DUCTWORK FOR EACH DAMPER FOR ACCESS TO
FUSIBLE LINKS. CONTRACTOR SHALL ASSURE ACCESS THRU CEILING AND
STRUCTURE.
Fire Damper Details
3/32" = 1'-0"
ALTERNATE CADDY-CLIP TYPE FASTENER TO
BARJOIST WITH STRAP
WRAP AROUND JOIST OR OTHER SUPPORT #8
SCREWS
DUCTMATE #CL-10 "CLUTCHER" WIRE ROPE
HANGER SYSTEM, SPACED 8' O.C. MAXIMUM
FOR SPRIRAL PIPE INTALLED IN 10' LENGTHS
18GA MINIMUM STRAP, 1" WIDE, 6' MAXIMUM
HORIZONTAL SPACING
LOW-RIB SPIRAL DUCT, MINIMUM 26GA
EQUIVALENT, GAUGE PER SMACNA
CONSTRUCTION STANDARDS
FIRE RATED
FLOOR/CEILING
ASSEMBLY-SEE
ARCH. DWGS.
FOR DETAILS
CEILING RADIATION DAMPER
18" DEEP OPEN WEB TRUSSES
FLOOR ABOVE
AH LOCATED ABOVE TUB
#8 SCREW AT TOP OF DUCT
TRANSFER
OPENING
TURN STRAP UNDER DUCT 1" WITH #8 SCREW
ALL MATERIALS LOCATED
WITHIN THE RA PLENUM SHALL
BE PLENUM RATED AND
COMPLY WITH IMC 602.2.1 AND
602.2.1.1.
SA GRILLE
FLEX DUCT ROUTED
TO SA PLENUM
RIGID DUCT INSTALLATION
CEILING
MAINTAIN 14" CLEAR IN
PLENUM, MIN.
FURR-DOWN
RA GRILLE W/FILTER
(ALT. LOC. IN WALL)
W/TRANSFER DUCT AS
IDICATED ON PLANS
ACCESS PANEL
1
Ceiling Diffuser Detail
12" = 1'-0"
LIVING SPACE
SA PLENUM - SEE
DWGS. FOR SIZE
DUCT ACCESS
FUR-DOWN
ACCESS PANEL
HALLWAY
BATHROOM
3.
4.
PROVIDE SECONDARY CONDENSATE DRAIN ROUTED IN ESCUTCHEON TO DISCHARGE OVER TUB. PROVIDE
DISCHARGE CAP FOR A NEAT AND CLEAN APPEARANCE.
ALL PLENUM PENETRATIONS TO BE SEALED AIRTIGHT.
Section Through Bathroom Detail-Typical
12" = 1'-0"
DRYERBOX® RECEPTACLE (WWW.DRYERBOX.COM) SHALL BE METAL AND
BE INSTALLED AS LOW AS POSSIBLE AS TO PERMIT THE PROPER AND
SAFE COLLECTION OF THE DRYER TRANSITION HOSE. DRYERBOX
SHOULD BE RESTING ON THE BOTTOM PLATE AND BE LOCATED AT OR
NEAR THE CENTERLINE OF THE PROPOSED DRYER APPLIANCE. RIGID
DUCT SHOULD PENETRATE DRYERBOX PORT 2 INCHES TO PROVIDE FOR
FUTURE CONNECTION AND STORAGE OF TRANSITION HOSE. BASEBOARD
SHALL BE "BUTTED" UP TO THE FIXED EXTENSION RIM AND SLIGHTLY
BACK-CUT. DRYERBOX SHOULD BE CAULKED AND THEN PAINTED WITH
THE TRIM PAINT. FOR USAGE IN A ONE-HOUR WALL ASSEMBLY, UL
REQUIRES THAT BATT INSULATION BE STUFFED AROUND THE DRYERBOX
AND IN THE ENTIRE WALL CAVITY CELL.
LENGTH OF CONCEALED RIGID METAL DUCTING SHALL NOT EXCEED 25
FEET. DEDUCT 5 FEET FROM THE ALLOWABLE LENGTH FOR EVERY 3.5"
RADIUS 90 DEGREE ELBOW AND TWO AND A HALF FEET FOR EVERY 45
DEGREE FITTING. DRYER VENTING SHALL BE INDEPENDENT OF ANY
OTHER SYSTEMS (CHIMNEYS OR EXHAUST VENTS). TERMINATION OF
DRYER VENTING MUST BE TO THE EXTERIOR WITH A PROPER HOOD OR
ROOF JACK EQUIPPED WITH A BACK-DRAFT DAMPER. SMALL ORIFICE
METAL SCREENING SHOULD NOT BE PART OF THE HOOD OR ROOF JACK
AS THIS WILL ACCELERATE LINT ACCUMULATION AND BLOCKAGE. THE
HOOD OPENING SHOULD POINT DOWN AND EXHIBIT 12 INCHES OF
CLEARANCE BETWEEN THE BOTTOM OF THE HOOD AND THE GROUND OR
OTHER OBSTRUCTION. VERIFY MANUFACTURER'S RECOMMENDATIONS
FOR ANY OTHER FACTORS.
LENGTH OF CONCEALED RIGID METAL DUCTING SHALL NOT EXCEED 25
FEET. DEDUCT 5 FEET FROM THE ALLOWABLE LENGTH FOR EVERY 3.5"
RADIUS 90 DEGREE ELBOW AND TWO AND A HALF FEET FOR EVERY 45
DEGREE FITTING. DRYER VENTING SHALL BE INDEPENDENT OF ANY
OTHER SYSTEMS (CHIMNEYS OR EXHAUST VENTS). TERMINATION OF
DRYER VENTING MUST BE TO THE EXTERIOR WITH A PROPER HOOD OR
ROOF JACK EQUIPPED WITH A BACK-DRAFT DAMPER. SMALL ORIFICE
METAL SCREENING SHOULD NOT BE PART OF THE HOOD OR ROOF JACK
AS THIS WILL ACCELERATE LINT ACCUMULATION AND BLOCKAGE. THE
HOOD OPENING SHOULD POINT DOWN AND EXHIBIT 12 INCHES OF
CLEARANCE BETWEEN THE BOTTOM OF THE HOOD AND THE GROUND OR
OTHER OBSTRUCTION. VERIFY MANUFACTURER'S RECOMMENDATIONS
FOR ANY OTHER FACTORS.
REFRIGERANT PIPING
LINE SETS TO
CONDENSING UNITSIZED BASED ON MFG
RECOMMEDNATIONS
FILTER SECTION
100821
FE
COOLING
COIL
AIR HANDLER
A
TRENT E BEIGHLE
S.A. DUCT
LIC
SS
E NS ED IN
G
IONA L EN
PE-SERVICES
F-10841
EXP: 11/30/12
BUILDING WALL
R.A. DUCT
DRYERBOX® RECEPTACLE (WWW.DRYERBOX.COM) SHALL BE METAL AND
BE INSTALLED AS LOW AS POSSIBLE AS TO PERMIT THE PROPER AND
SAFE COLLECTION OF THE DRYER TRANSITION HOSE. DRYERBOX
SHOULD BE RESTING ON THE BOTTOM PLATE AND BE LOCATED AT OR
NEAR THE CENTERLINE OF THE PROPOSED DRYER APPLIANCE. RIGID
DUCT SHOULD PENETRATE DRYERBOX PORT 2 INCHES TO PROVIDE FOR
FUTURE CONNECTION AND STORAGE OF TRANSITION HOSE. BASEBOARD
SHALL BE "BUTTED" UP TO THE FIXED EXTENSION RIM AND SLIGHTLY
BACK-CUT. DRYERBOX SHOULD BE CAULKED AND THEN PAINTED WITH
THE TRIM PAINT. FOR USAGE IN A ONE-HOUR WALL ASSEMBLY, UL
REQUIRES THAT BATT INSULATION BE STUFFED AROUND THE DRYERBOX
AND IN THE ENTIRE WALL CAVITY CELL.
FLEXIBLE
CONNECTION
(TYPICAL)
O
DRYER VENTING: MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE
FOR RUNNING ALL DUCTWORK FOR THE DRYER EXHAUST SYSTEM. ALL
CONCEALED DRYER DUCTING MUST BE RIGID METAL (GALVANIZED OR
ALUMINUM) MINIMUM OF 4" IN DIAMETER, SMOOTH 30 GA. CLEAN,
UNOBSTRUCTED, FRICTIONLESS DUCTS (NO FLEXIBLE DUCT ALLOWED IN
CONCEALED AREAS). SEAL ALL JOINTS WITH FOIL BACKED PRESSURE
SENSITIVE DUCT TAPE MEETING THE REQUIREMENTS OF UL 181. DUCT
JOINTS SHALL BE INSTALLED SO THAT THE MALE END OF THE DUCT
POINTS IN THE DIRECTION OF THE AIRFLOW. DO NOT USE RIVETS OR
SCREWS IN THE JOINTS OR ANYWHERE ELSE IN THE DUCT AS THESE WILL
ENCOURAGE LINT COLLECTION.
PR
DRYER VENTING: MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE
FOR RUNNING ALL DUCTWORK FOR THE DRYER EXHAUST SYSTEM. ALL
CONCEALED DRYER DUCTING MUST BE RIGID METAL (GALVANIZED OR
ALUMINUM) MINIMUM OF 4" IN DIAMETER, SMOOTH 30 GA. CLEAN,
UNOBSTRUCTED, FRICTIONLESS DUCTS (NO FLEXIBLE DUCT ALLOWED IN
CONCEALED AREAS). SEAL ALL JOINTS WITH FOIL BACKED PRESSURE
SENSITIVE DUCT TAPE MEETING THE REQUIREMENTS OF UL 181. DUCT
JOINTS SHALL BE INSTALLED SO THAT THE MALE END OF THE DUCT
POINTS IN THE DIRECTION OF THE AIRFLOW. DO NOT USE RIVETS OR
SCREWS IN THE JOINTS OR ANYWHERE ELSE IN THE DUCT AS THESE WILL
ENCOURAGE LINT COLLECTION.
SIZED BASED ON MFG
RECOMMEDNATIONS SEE
PLANS FOR PENETRATION
LOCATIONS.
OF TE
TE
X
R
DRYERBOX INSTALLATION
TA
S
DRYERBOX INSTALLATION
FIRRING STRIP
ROUTE AIR HANDLER CONDENSATE DRAIN TO LAVATORY TAIL PIECE.
S
7
PERMIT SET
NOTES:
1.
BATHROOM WALLS SHALL BE FULL HEIGHT FROM FINISHED FLOOR TO BOTTOM OF RATED ASSEMBLY.
HVAC Details
FINISHED FLOOR
2.
Nacogdoches, TX
USE DRAW BANDS AT CONNECTION POINTS
OF FLEXIBLE WITH RIGID DUCT & AT DIFFUSER
FLEX DUCT INSTALLATION
EXHAUST FAN IN WALL
SEAL AND TAPE OUTER
JACKET AT RIGID DUCT AND
DIFFUSER NECK
1. ANGLES SHALL BE A MINIMUM OF 1-1/2x1-1/2x1/8. FASTEN TO COLLAR ONLY W/ 1/4"
DIA. NUTS BOLTS. ANGLES REQ'D ON ALL FOUR SIDES OF WALL OR FLOOR SLAB.
(TYP. ALL FIRE DAMPERS)
EE
MINIMUM 2
DUCT
DIAMETERS
NOTES:
UL LISTED FLOOR
PLATE PENETRATION
LUMBERJACK LOFTS
SFA 1411 ASSOCIATES, L.P.
SEAL JOINTS IN ROUND RIGID DUCT &
AT TAPS WITH MAIN
INTERIOR
PARTITION WALL
HAVING ADEQUATE
DEPTH FOR
INSTALLATION OF
WALL FAN.
UL LISTED TOP PLATE
PENETRATION
TOP PLATE SHALL BE CUT AND
FIRESTOPPED USING APPROVED
FIRE STOP MATERIAL
L.P. HORIZONTAL MOUNTING
RETURN PLENUM SIZED TO
MATCH UNIT OPENING
ARCHITECTURE DEMAREST
CONDENSATE DRAIN
(DRAIN TO NEAREST
FLOOR DRAIN OR
MOP SINK)
FIRRING STRIP ON
2X4
2"
FIRRING STRIP ADDED
TO 2X4 TO ACHIEVE
ADEQUATE DEPTH FOR
MODEL 425
FIRRING STRIP ADDED
TO 2X4 TO ACHIEVE
ADEQUATE DEPTH FOR
MODEL 4D
FLEX TRANSITION
HOSE
CONCRETE PAD
(BY G.C.)
FLEX TRANSITION
HOSE
RIDGID PIPE NOT TO EXCEED
2" THROUGH DRYER BOX
2"
SEE DETAIL
SEE DETAIL
REFER TO NOTES
REFER TO NOTES
TURNING VANES
(TYPICAL ALL ELBOWS)
DATE
07/16/12
DRYERBOX
DRYERBOX
C ARCHITECTURE DEMAREST, L.P.
ALL RIGHTS RESERVED
RIDGID PIPE NOT TO EXCEED
2" THROUGH DRYER BOX
Revision Schedule
No. Date
Description
MOUNT DRYERBOX AS LOW AS
POSSIBLE UNLESS YOU HAVE A
PEDASTAL OR STACKABLE DRYER
MOUNT DRYERBOX AS LOW AS
POSSIBLE UNLESS YOU HAVE A
PEDASTAL OR STACKABLE DRYER
4" RIGID METAL
6
Dryer Box Details
3/4" = 1'-0"
8
Furnace Detail
12" = 1'-0"
JOB NO.
10051
SHEET NO.
COPYRIGHT (C) 2011 ARCHITECTURE DEMAREST, L.P. ALL IDEAS, DESIGNS, ARRANGEMENTS, PLANS, AND SPECIFICATIONS INDICATED OR REPRESENTED BY THIS DRAWING AS INSTRUMENTS OF SERVICE ARE AND SHALL REMAIN THE EXCLUSIVE INTELLECTUAL PROPERTY OF ARCHITECTURE DEMAREST, L.P. AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THIS SPECIFIED PROJECT ONLY. NONE OF SUCH
IDEAS, DESIGN, ARRANGEMENTS OR PLANS SHALL BE USED ON ANY OTHER PROJECT OR EXTENSIONS OF THIS PROJECT OR USED BY OR DISCLOSED TO ANY PERSON, FIRM OR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION FORM AND APPROPRIATE COMPENSATION TO ARCHITECTUREDEMAREST, L.P. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. THE CONTRACTOR
SHALL BEAR SOLE RESPONSIBILITY FOR VERIFYING ALL DIMENSIONS ON THIS PROJECT AND NOTIFIYING ARCHITECTURE DEMAREST, L.P. OF ANY DEVIATIONS. THE CONTRACTOR SHALL BEAR SOLE RESPONSIBILITY FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, CONFIRMING COORDINATION AND FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT. ARCHITECTURE DEMAREST, L.P.
WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT.
M300
GENERAL NOTES:
PLUMBING LEGEND:
THIS IS A TYIPCAL LEGEND. NOT ALL SYMBOLS MAY BE USED.
E. ALL PLUMBING FIXTURES SHALL BE SUPPLIED WITH INDIVIDUAL HEAVY DUTY SUPPLY STOPS
AND CODE APPROVED P-TRAPS WITH CLEANOUTS. EXPOSED PIPING SHALL BE CHROME
PLATED WITH CHROMED ESCUTCHEONS AT WALL PENETRATIONS.
F. NO PIPING SHALL PASS DIRECTLY OVER ELECTRICAL POWER DISTRIBUTION CABINETS.
CONTRACTOR SHALL COORDINATE PANEL LOCATIONS PRIOR TO PIPING INSTALLATION.
G. ALL FLOOR DRAIN TRAPS SHALL BE PROVIDED WITH TRAP PRIMERS PER LOCAL CODES
HAVING JURISDICTION.
H. ALL HORIZONTAL VENT PIPING MAY NOT BE SHOWN ON THIS PLAN FOR THE SAKE OF
CLARITY. REFER TO SANITARY ISOMETRIC FOR VENT PIPING ROUTING AND PROVIDE
COMPLETE VENTING SYSTEM IN ACCORDANCE WITH CODE.
I. ALL PLUMBING WORK SHALL BE COORDINATED WITH ALL OTHER TRADES PRIOR TO
PROCEEDING WITH INSTALLATION.
J. ALL DOMESTIC WATER BRANCH LINES SHALL HAVE FULL PORT, TWO PIECE BALL TYPE
ISOLATION VALVES.
K. PROVIDE WATER HAMMER ARRESTORS (WHA) AT ALL WATER PIPE DROPS TO FIXTURES
WITH QUICK CLOSING VALVES AND ON SYSTEMS WITH HIGHER THAN NORMAL PRESSURE
WHERE WATER HAMMER MAY BE AN ISSUE.
L. INSTALL ALL FLOOR CLEANOUTS TO CLEAR EQUIPMENT AND PROVIDE REQUIRED
ACCESSIBILITY FOR MAINTENANCE.
M. VERIFY INVERT ELEVATIONS AND EXACT LOCATIONS OF ALL UNDERGROUND UTILITIES PRIOR
TO INSTALLING ANY UNDERGROUND PIPING. COORDINATE WITH SITE UTILITY CONTRACTOR.
ELECTRIC WATER HEATER SCHEDULE
TAG
FIXTURE
PIPING
CONNECTIONS
CW
DHW
DESCRIPTION
ELECTRICAL
REQUIREMENTS
KW
VOLT
PH
HZ
TANK
RECOVERY
CAPACITY
CAPACITY
GALLONS GALLONS TEMP
REFERENCE
PRODUCT
ACCEPTABLE
EQUALS
BRADFORD-WHITE
RHEEM
STATE
XX
3/4
3/4
4.5
208
1
60
50
23
80 DEG
AO SMITH
DURA-POWER
DEL-50
EWH-1
ELECTRIC WATER HEATER
TANK TYPE
GLASS LINED TANK, FOAM INSULATED, ZINC PLATED COPPER SHEATHS WITH MEDIUM WATT DENSITY, SINGLE
HEATING ELEMENT, SINGLE PHASE, ADJUSTABLE TEMPERATURE CONTROL 110-170 DEG F, CABIINET BONDERIZED
UNDERCOAT WITH BAKED ENAMEL FINISH
EWH-2
ELECTRIC WATER HEATER
TANK TYPE
GLASS LINED TANK, FOAM INSULATED, ZINC PLATED COPPER SHEATHS WITH MEDIUM WATT DENSITY, DUAL
HEATING ELEMENTS, SINGLE PHASE, ADJUSTABLE TEMPERATURE CONTROL 110-170 DEG F, CABIINET
BONDERIZED UNDERCOAT WITH BAKED ENAMEL FINISH
3/4
3/4
4.5
208
1
60
80
23
80 DEG
AO SMITH
DURA-POWER
DEN-80
BRADFORD-WHITE
RHEEM
STATE
EWH-3
ELECTRIC WATER HEATER
TANK TYPE
GLASS LINED TANK, FOAM INSULATED, ZINC PLATED COPPER SHEATHS WITH MEDIUM WATT DENSITY, DUAL
HEATING ELEMENTS, SINGLE PHASE, ADJUSTABLE TEMPERATURE CONTROL 110-170 DEG F, CABIINET
BONDERIZED UNDERCOAT WITH BAKED ENAMEL FINISH
3/4
3/4
4.5
208
1
60
20
23
80 DEG
AO SMITH
DURA-POWER
DEL-20
BRADFORD-WHITE
RHEEM
STATE
EWH-4
ELECTRIC WATER HEATER
INSTANTANEOUS
SINGLE POINT
ELECTRIC INSTANTANEOUS WATER HEATER, ABS UL RATED COVER, GLASS REINFORCED "NORYL" HEATER BODY
AND NI CHROME ELEMENT, REPLACEABLE ELEMENT CARTRIDGE 3/8" COMPRESSION PIPE FITTINGS, WALL
MOUNT, WHITE COVER, 3 POUNDS
3/8
3/8
3.5
120
1
60
-
.5
48DEG
EEMAX
SP3513
ARISTON
BOSCH CHRONOMITE
XX
X.X
FULL PORT BALL VALVE
S
FLOOR CONTROL VALVE
SWING CHECK VALVE
FULL PORT BALL VALVE ON DROP
PRESSURE REDUCING VALVE (___ PSIG)
BACKFLOW DEVICE (___ TYPE)
BUTTERFLY VALVE
CONTROL VALVE
FCO
FLOOR CLEANOUT
WCO
WALL CLEANOUT
GCO
GRADE CLEANOUT
HCO
HORIZONTAL CLEANOUT
DOMESTIC COLD WATER
DOMESTIC HOT WATER
DOMESTIC HOT WATER RETURN
SANITARY PIPING
VENT PIPING
G
GAS PIPING
EXISTING
DEMO
POINT OF CONNECTION
SANITARY UNDERGROUND PIPING
FOG
FATS, OILS, AND GREASE (FOG) PIPING
Nacogdoches, TX
D. DOMESTIC WATER PIPING BELOW GRADE OR SLAB SHALL BE BRAZED TYPE 'K' COPPER,
WATER PIPING ABOVE SLAB SHALL BE SOLDERED TYPE 'L' OR MECHANICAL CRIMP JOINT.
INSULATE WATER PIPING WITH
" ARMAFLEX
1/2
II OR EQUAL BY RUBATEX OR ARMACELL.
BALL VALVE
LUMBERJACK LOFTS
SFA 1411 ASSOCIATES, L.P.
C. ALL VENT PIPING SHALL BE SOLVENT SEAL SCHEDULE 40 PVC-DWV OR THREADED
GALVANIZED STEEL. MATERIAL SHALL COMPLY WITH CODE REQUIREMENTS. NO PVC SHALL
BE USED IN RETURN AIR PLENUM.
AREA DRAIN
ABOVE FINISH FLOOR
BACKFLOW PREVENTER
BATHTUB
CLEANOUT
COMBINATION WATER SERVICE
DOMESTIC COLD WATER
DECK DRAIN
DRINKING FOUNATIN
DOMESTIC HOT WATER
DOWN
DOWNSPOUT
ELECTRICAL CONTRACTOR
EXPANSION TANK
ELECTRIC WATER COOLER
ELECTRIC WATER HEATER
FIRE LINE
FLOOR DRAIN
FIRE DEPT. CONNECTION
FIRE RISER
FLOW SWITCH
FIRE SUPPRESSION CONTRACTOR
GENERAL CONTRACTOR
GREASE INTERCEPTOR
GRADE
GAS-FIRED WATER HEATER
HOSE BIBB
HVAC CONTRACTOR
HUB DRAIN
HEIGHT
INVERT ELEVATION
LAVATORY
LINEAR FOOT
MAXIMUM
MOP BASIN
MINIMUM
MOP SINK
NATURAL GAS
NOT TO SCALE
NON-POTABLE
OVERFLOW DRAIN
PLUMBING CONTRACTOR
ROOF DRAIN
SPRINKLER LINE
SANITARY
SPRINKLER DRAIN LINE
SHOWER
SQUARE FOOT
SUMP PUMP
SANITARY SEWER
SUBSURFACE DRAINAGE
STORM
SITE UTILITY CONTRACTOR
TRENCH DRAIN
THERMOSTATIC MIXING VALVE
TRAP PRIMER
TYPICAL
UTILITY FIXTURE
UNDERGROUND
URINAL
VENT
VENT RISER
VENT THRU ROOF
WATER CLOSET
WALL HYDRANT
WATER HAMMER ARRESTOR
Plumbing
Legend, Notes,
and Schedules
B. ALL UNDERGROUND SANITARY WASTE PIPING SHALL BE SOLVENT SEAL SCHEDULE 40
PVC-DWV OR GASKETED HUB/SPIGOT CAST IRON. ABOVE GROUND SHALL BE SOLVENT
SEAL SCHEDULE 40 PVC-DWV OR HUBLESS CAST IRON WITH MECHANICAL COUPLINGS AND
SLOPED A MINIMUM OF 1/8
" PER FOOT (3'' OR LARGER) AND 1/4
'' PER FOOT (2'' AND
SMALLER) WHERE INSTALLED IN THE HORIZONTAL POSITION. MATERIAL SHALL COMPLY WITH
CODE REQUIREMENTS.
AD
AFF
BFP
BT
CO
CWS
DCW
DD
DF
DHW
DN
D.S.
E.C.
ET
EWC
EWH
F
FD
F.D.C.
FR
FS
F.S.C.
G.C.
GI
GRD
GWH
HB
H.C.
HD
HT
INV
LV
LF
MAX
MB
MIN
MS
NG
NTS
NP
OFD
P.C.
RD
S
SAN
SD
SH
SF
SP
SS
SSD
ST
S.U.C.
TD
TMV
TP
TYP
UF
UG
UR
V
V.R.
V.T.R.
WC
WH
WHA
PLAN NOTE REFERENCE
DETAIL NOTE REFERENCE
PERMIT SET
A. THIS WORK SHALL BE EXECUTED IN STRICT CONFORMITY WITH BASE BUILDING
SPECIFICATION AND WITH THE LATEST EDITION OF THE PREVAILING STATE PLUMBING AND
BUILDING CODES AND ALL LOCAL REGULATIONS THAT MAY APPLY. IN CASE OF CONFLICT
BETWEEN THE CONTRACT DOCUMENTS AND A GOVERNING CODE OR ORDINANCE THE MORE
STRINGENT STANDARD SHALL APPLY.
NOTES:
ACCEPTABLE
EQUALS
SYMMONS ALLURA
#S-4702-2.0
STERLING 71110122 (RIGHT
HAND) 71110112 (LEFT HAND)
AO SMITH
KOHLER
ELJER
SYMMONS WATER
DANCE 1-7520-X W/
24" SLIDE BAR
STERLING 71150115 (RIGHT
HAND) 71150125 (LEFT HAND)
AO SMITH
KOHLER
ELJER
FIXTURE
DESCRIPTION
FAUCETS/ FITTINGS
BT-1
BATH TUB
TRADITIONAL LOOK, TILE WITHOUT GROUT LINES, FOUR PIECE DEISGN MADE OF VIKRELL MATERIAL,
16" APRON, HIGH-GLOSS FINISH
BT-1A
ADA TUB
TRADITIONAL LOOK, TILE WITHOUT GROUT LINES, FOUR PIECE DEISGN MADE OF VIKRELL MATERIAL,
16" APRON, HIGH-GLOSS FINISH, WITH SEAT
WF-1
DRINKING
FOUNTAIN-EXTERIOR
EXTERIOR, SINGLE LEVEL UNIT WITH FRONT PUSH BUTTON, STAINLESS STEEL CONSTRUCTION,
VANDAL RESISTANT SCREWS, RATED FOR BOTH INDOOR AND OUTDOOR
TRIM
ACCESSORIES
REFERENCE
TA
OF TE
TE
X
A
S
PRODUCT
TAG
S
PLUMBING FIXTURE SCHEDULE
TRENT E BEIGHLE
O
FE
EWC-1
ELECTRIC WATER COOLER
BI-LEVEL UNIT, WALL HUNG, UL AND CSA LISTED, LEAD-FREE WATERWAYS STAINLESS STEEL TOP,
HIGH EFFICIENCY COOLING TANK AND MOTOR WELDED HEAVY DUTY FRAME, ADA COMPLIANT
ELKAY EZ8
OASIS
HAWS
HALSEY TAYLOR
FCO
FLOOR CLEANOUT
ADJUSTABLE POLISHED BRONZE FLOOR CLEANOUT, DURA-COATED CAST IRON BODY WITH GAS AND
WATER TIGHT ABS TAPERED THREAD PLUG, ROUND SECURED TOP, VANDAL PROOF SCREWS, NO HUB
CONNECTION
ZURN Z-1400-VP
JR SMITH
WADE
WATTS
FD-1
FLOOR DRAIN
DURA-COATED CAST IRON BODY WITH BOTTOM OUTLET, COMBINATION INVERTIBLE MEMBRANE
CLAMP AND ADJUSTABLE COLLAR, TYPE 'B' STRAINER TRAP PRIMER CONNECTION, 1 - 3" EXTENSION
ADAPTER, VANDAL PROOF SCREWS
ZURN Z-415-P-VP-B
JR SMITH
WADE
WATTS
HB-1
FREEZEPROOF WALL
HYDRANT ENCASED
FREEZEPROOF ENCASED WALL HYDRANT, CAST NICKEL BRONZE BOX, SELF-DRAINING, ANTI-SIPHON,
REPLACEABLE SEAT, ONE-PIECE VALVE ASSEMBLY, CHROME PLATED BRASS OPERATING SCREW, 3/4"
SOLID BRASS ROD
ZURN Z-1300
JR SMITH
WADE
WATTS
AMERICAN STANDARD
LUCERNE 0355.012
KOHLER
ELJER
AMERICAN STANDARD
AQUALYN 0476.028
KOHLER
ELJER
OUTDOOR SHOWER
COMPANY RAINCAN GL150-4
LEONARD
POWERS
ELKAY LR-1720
JUST
KOHLER
AMERICAN STANDARD
STERLING 14633-4
JUST
KOHLER
AMERICAN STANDARD
AMERICAN STANDARD
WASHBROOK 6501.010
ELJER
KOHLER
LV-2
LAVATORY
WALL HUNG
ADA
VITREOUS CHINA WALL HUNG, FRONT OVERFLOW, D-SHAPED BOWL, CONCEALED ARM SUPPORTS, 4"
OC FAUCET HOLES, FAUCET LEDGE, SELF DRAIN DECK AREA CONTOURED SIDE AND BACK SPLASH
SHIELDS, LEVER HANDLE FAUCET.
LV-1
LAVATORY
COUNTER
VITREOUS CHINA, COUNTER TOP, 20 X 18 OVAL BOWL, SELF RIMMING, FRONT OVERFLOW, 4" O.C.
FAUCET HOLES, FAUCET LEDGE, LEVER HANDLE FAUCET OVERFLOW, 4" O.C. FAUCET HOLES, FAUCET
LEDGE, LEVER HANDLE FAUCET.
SH-1
SHOWER
TRIM ONLY
PRESSURE BALANCING MIXING VALVE, ADJUSTABLE STOP SCREW, SINGLE BRONZE STEM, STAINLESS
STEEL HOUSING, 8" SHOWER HEAD
ZURN -81101
McGUIRE 165
TRUEBRO
MODEL 102
TRAP WRAP KIT
LIC
SS
E NS ED IN
G
IONA L EN
PE-SERVICES
F-10841
EXP: 11/30/12
ARCHITECTURE DEMAREST
ZURN -81102
KS-2
SINK
SINGLE BOWL
17x20x7-1/2 DEEP
18 GAUGE STAINLESS STEEL SINGLE COMPARTMENT COUNTER TOP SINK, SELF-RIMMING, HAND
BLENDED SATIN FINISH, 3-1/.2" DRAIN OPENING, 3 HOLE PUNCH, 8" O.C. HEAVY DUY SOUND COATED
UNDERSIDE,
ZURN Z-831A1 LEVER
HANDLES
KS-1
SINK
DOUBLE BOWL
22x33 OVERALL
18 GAUGE STAINLESS STEEL DOUBLE COMPARTMENT COUNTER TOP SINK, SELF-RIMMING, HAND
BLENDED SATIN FINISH, 3-1/.2" DRAIN OPENING, 3 HOLE PUNCH, 8" O.C. HEAVY DUY SOUND COATED
UNDERSIDE,
AMERICAN
STANDARD 4175.201
UR-1
URINAL
WALL HUNG, ADA
VITREOUS CHINA WALL HUNG, REAR OUTLET, TOP SPUD, FLUSHING RIM, LOW CONSUMPTION,
WASHOUT FLUSH ACTION EXTENDED PRIVACY SHIELDS, 2 INCH OUTLET CONNECTION, WALL
HANGERS, MEETS ANSI FLUSH REQUIREMENTS-ADA COMPLIANT
SLOAN ROYAL 186-1
FLUSH VALVE
McGUIRE 165
GARBE DISPOSAL
WC-1
WATER CLOSET
FLOOR MOUNT
TANK TYPE
VITREOUS CHINA, TWO-PIECE, FLOOR MOUNT, TANK TYPE,14" HIGH ELONGATED BOWL SIPHON JET
ACTION, CLOSE COUPLED TANK, 3 BOLT SYSTEM, FULLY GLAZED 2" TRAPWAY 1.6 GAL PER FLUSH,
POLISHED CHROME TRIP LEVER, 12" ROUGH IN
OLOSNITE 64
WHITE PLASTIC
SEAT
AMERICAN STANDARD
CADET 2333.100
ELJER
KOHLER
WC-1A
WATER CLOSET
FLOOR MOUNT
TANK TYPE-ADA
VITREOUS CHINA, TWO-PIECE, FLOOR MOUNT, TANK TYPE,17" HIGH ELONGATED BOWL SIPHON JET
ACTION, CLOSE COUPLED TANK, 3 BOLT SYSTEM, FULLY GLAZED 2" TRAPWAY 1.6 GAL PER FLUSH,
POLISHED CHROME TRIP LEVER, 12" ROUGH IN-ADA COMPLIANT
OLOSNITE 64
WHITE PLASTIC
SEAT
AMERICAN STANDARD
CADET 2377.100
ELJER
KOHLER
WALL CLEANOUT
DURA-COATED CAST IRON BODY WITH GAS AND WATER TIGHT ABS TAPERED THREAD PLUG, ROUND
SMOOTH, STAINLESS STEEL ACCESS COVER WITH SECURING VANDAL PROOF SCREW, NO HUB
CONNECTION
ZURN ZB-1441-VP
JR SMITH
WADE
WCO
EE
R
100821
PR
ELKAY VRC8S
ELJER, OASIS,
HALSEY TAYLOR
WB-1
WAHSER
MACHINE
BOX
OATELY
38894
COPYRIGHT (C) 2011 ARCHITECTURE DEMAREST, L.P. ALL IDEAS, DESIGNS, ARRANGEMENTS,
PLANS, AND
SPECIFICATIONS
INDICATED OR REPRESENTED BY THIS DRAWING AS INSTRUMENTS OF SERVICE ARE AND SHALL REMAIN THE EXCLUSIVE INTELLECTUAL PROPERTY OF ARCHITECTURE DEMAREST, L.P. AND
WERE
CREATED, EVOLVED AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THIS SPECIFIED PROJECT ONLY. NONE OF SUCH
IDEAS, DESIGN, ARRANGEMENTS OR PLANS SHALL BE USED ON ANY OTHER PROJECT OR EXTENSIONS OF THIS PROJECT OR USED BY OR DISCLOSED TO ANY PERSON, FIRM OR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION FORM AND APPROPRIATE COMPENSATION TO ARCHITECTUREDEMAREST, L.P. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. THE CONTRACTOR
SHALL BEAR SOLE RESPONSIBILITY FOR VERIFYING ALL DIMENSIONS ON THIS PROJECT AND NOTIFIYING ARCHITECTURE DEMAREST, L.P. OF ANY DEVIATIONS. THE CONTRACTOR SHALL BEAR SOLE RESPONSIBILITY FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, CONFIRMING COORDINATION AND FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT. ARCHITECTURE DEMAREST, L.P.
WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES,
SEQUENCES,ICE
PROCEDURES,
WITH THIS PROJECT.
IMB-1
MAKER BOXOR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION
FIRE RATED
OATLEY 38492
C ARCHITECTURE DEMAREST, L.P.
ALL RIGHTS RESERVED
DATE
07/16/12
Revision Schedule
No. Date
Description
JOB NO.
10051
SHEET NO.
P100
3
A1
A1
A1
DW.
REFR.
DW.
REFR.
DW.
DW
REFR.
DWDW.
D1
D1
A1
WD
DW.
REFR.
WD
B1
DW.
DW.
REFR.
B1
DW.
DW.
REFR.
D1
DW.
REFR.
DW.
REFR.
DW.
STAIRS
UP WHWD
DW
REFR.
WD
WHWD
DW.
REFR.
REFR.
WD
REFR.
B2
D1
RM MANAGER
WOMEN WORK
ASST. MGR.
STAIRS
UP
REF.
FD-1
KEYNOTES
B2ALT
D1
WF-1
B1
D1
UPDN
2" WATER STUB WITH SHUT OFF VALVE
FOR POOL EQUIPMENT. COORDINATE EXACT
LOCATION OF ENTRY POINT WITH POOL
EQUIPMENT PRIOR TO INSTALLATION.
1
DWWH
R.
REF
.
DWD1
H
DWW
R.
REF
.
DWB1
DW
.
EF. R
RW
D
?
A1
DW
WC-1
DW.
R.
REF
DW.
R.
REF
DW
DW.
R.
REF
2. SLOPE HORIZONTAL DRAINAGE PIPING MINIMUM 1/8" PER FOOT.
SH-1
WD
GENERAL NOTES
LV-2
1. REFER TO ENLARGED PLANS FOR ADDITIONAL PIPE SIZES AND
ROUTING.
WC-1
DW.
R.
REF
B1
WD
LV-2
WF-1
.
D1
Plumbing Site
Plan
ROUTE 3/4" CW UNDERGROUND TO DUMPSTER STATION.
CONNECT 3/4" CW TO NON-FREEZE HYDRANT WITH
REMOVABLE TEE HANDLE EQUAL TO JR SMITH MODEL 5509-QT.
DWDW
BREEZEWAY
DWWH
R.
REF
H
DWW
DW
W
DD1-HC
R.
REF
DW
B1-HC
A1-HC
1
REFR.
DW
PERMIT SET
3
DW.
4" COMBINATION WATER SERVICE. REFER TO CIVIL PLANS FOR
CONTINUATION.
DWWH
2
REFR.
WATER HEATER MOUNTED ON SHELF.
COORDINATE EXACT LOCATION WITH POOL
EQUIPMENT PRIOR TO INSTALLATION.
6" SANITARY SEWER. REFER TO CIVIL PLAN FOR CONTINUATION.
REFR.
2" WATER BELOW GRADE FROM
CLUBHOUSE.
1
DW.
Plumbing Pool Equipment Room Sanitary
Plan
4
1/4" = 1'-0"
WD
DW.
REFR.
WD
COORDINATE WITH POOL
EQUIPMENT PRIOR TO
INSTALLATION.
2
DWWH
WC-1
DW.
WC-1
MEN
Nacogdoches, TX
3"ø
REFR.
4"ø
3"ø
FD-1
COMMUNITY
SPACE
CO
REFR.
FD-1
3"ø
FD-1
4"ø
LV-2
REF.
3"ø
2
UP
STAIRS
MAIL ROOM
FITNESS RM P.C. CENTER
ø
2"
2"ø
4"ø
2"ø
LV-2
ø
2"
WF-1
DWWH
WF-1
DW.
REFER TO CIVIL PLAN
FOR CONTINUATION.
WD
REFR.
B1
REFR.
WD
LUMBERJACK LOFTS
SFA 1411 ASSOCIATES, L.P.
B1
REFR.
DW.
DWWH
D1
DW.
REFR.
REFR.
DW.
STAIRS WHWD
REFR.
WHWD
DW.
DW
REFR.
REFR.
A1
WD
WHWD
A1
REFR.
DW.
REFR.
DW
REFR.
BREEZEWAY
DW
REFR.
DW
WHWD
DW.
A1
WD
DW.
A1
WD
DW.
D1
REFR.
DW.
D1
WD
DW.
B1
DW.
REFR.ALT
A1
REFR.
DW.
B1
D1
DW.
WD
3
ALT
WD
REFR.
DW.
A1
DW
1
1
2
REFR.
DW.
1
DW
2
ALT
2
3
S
TA
OF TE
TE
X
A
S
Plumbing Pool Equipment Room Supply
Plumbing Plan
3
1/4" = 1'-0"
TRENT E BEIGHLE
O
FE
EE
PR
R
100821
LIC
SS
E NS ED IN
G
IONA L EN
PE-SERVICES
F-10841
EXP: 11/30/12
REFER TO CIVIL DRAWINGS
FOR CONTINUATION
HB-1
3/4"ø
SHUT-OFF VALVE IN VALVE
BOX.
3/4"ø
ARCHITECTURE DEMAREST
C ARCHITECTURE DEMAREST, L.P.
ALL RIGHTS RESERVED
DATE
07/16/12
HB-1
Revision Schedule
No. Date
Description
JOB NO.
Plumbing Plan - Maintenance Building
2
1/4" = 1'-0"
Plumbing Overall PES Copy -Level 1
1
1" = 30'-0"
COPYRIGHT (C) 2011 ARCHITECTURE DEMAREST, L.P. ALL IDEAS, DESIGNS, ARRANGEMENTS, PLANS, AND SPECIFICATIONS INDICATED OR REPRESENTED BY THIS DRAWING AS INSTRUMENTS OF SERVICE ARE AND SHALL REMAIN THE EXCLUSIVE INTELLECTUAL PROPERTY OF ARCHITECTURE DEMAREST, L.P. AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THIS SPECIFIED PROJECT ONLY. NONE OF SUCH
IDEAS, DESIGN, ARRANGEMENTS OR PLANS SHALL BE USED ON ANY OTHER PROJECT OR EXTENSIONS OF THIS PROJECT OR USED BY OR DISCLOSED TO ANY PERSON, FIRM OR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION FORM AND APPROPRIATE COMPENSATION TO ARCHITECTUREDEMAREST, L.P. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. THE CONTRACTOR
SHALL BEAR SOLE RESPONSIBILITY FOR VERIFYING ALL DIMENSIONS ON THIS PROJECT AND NOTIFIYING ARCHITECTURE DEMAREST, L.P. OF ANY DEVIATIONS. THE CONTRACTOR SHALL BEAR SOLE RESPONSIBILITY FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, CONFIRMING COORDINATION AND FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT. ARCHITECTURE DEMAREST, L.P.
WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT.
10051
SHEET NO.
P101
REFER TO CIVIL DRAWINGS
FOR CONTINUATION.
REFER TO RISER DIAGRAMS
FOR CONTINUATION OF
SANITARY RISERS. TYPICAL
SANITARY RISER FOR UPPER
FLOOR ROOM BATH TUBS AND
WATER CLOSET.
4
D
4"ø
4"ø
4"ø
6"ø
REFR.
DW.
DW.
SANITARY RISER FOR UPPER
FLOOR WATER CLOSET.
TYPICAL.
3
P104
4" COMBINATION WATER AND FIRE
SPRINKLER LINE. REFER TO CIVIL
DRAWINGS FOR CONTINUATION.
PERMIT SET
REFER TO RISER DIAGRAMS
FOR CONTINUATION OF
SANITARY RISERS. TYPICAL
Sanitary Plan Section A - Enlarged A1
1
1/8" = 1'-0"
DCW RISER WITH ISOLATION VALVE PER
IPC CODE SECTION 606.1. REFER TO
UNIT PLANS AND RISER DIAGRAM FOR
MORE INFORMATION.
DCW RISER WITH ISOLATION VALVE PER
IPC CODE SECTION 606.1. REFER TO
UNIT PLANS AND RISER DIAGRAM FOR
MORE INFORMATION.
Nacogdoches, TX
W
CO
3"ø
4"ø
WH
6"ø
4"ø
4"ø
4"ø
4"ø
REFR.
D
LUMBERJACK LOFTS
SFA 1411 ASSOCIATES, L.P.
W
DW.
CO
W
4"ø
4"ø
4"ø
4"ø
3"ø
6"ø
REFR.
D
DW.
4"ø
3"ø
4"ø
4"ø
4"ø
3"ø
4"ø
4"ø
4"ø
3"ø
4"ø
4"ø
4"ø
4"ø
3"ø
REFR.
REFR.
WH
Plumbing Plan First Floor
Section A -A1
D
CO
6"ø
DW.
REFR.
D
W
4"ø
6"ø
4"ø
4"ø
REFR.
CO
6"ø
WH
REFR.
4"ø
4"ø
6"ø
CO
4"ø
4"ø
4"ø
4"ø
3"ø
D
D
D
W
W
W
WH
W
DW.
D
DW.
DW.
W
REFR.DW.
6"ø
P202
HB-1
4
3/4"ø
P202
S
TRENT E BEIGHLE
R
100821
FE
O
1 1/4"ø
W
REFR.
D
REFR.
1 1/4"ø
REFR.
WH
REFR.
REFR.
DW.
W
DW.
D
REFR.
D
REFR.
SS
E NS ED IN
G
IONA L EN
PE-SERVICES
F-10841
EXP: 11/30/12
1 1/4"ø
WH
REFR.
D
D
2"ø
W
W
2 1/2"ø
D
2 1/2"ø
WH
1 1/2"ø
1 1/2"ø
1 1/4"ø
2 1/2"ø
W
LIC
1 1/4"ø
WH
1 1/4"ø
A
EE
W
DW.
PR
D
D
W
W
D
DW.
OF TE
TE
X
S
REFR.DW.
DW.
DW.
TA
DW.
W
DW.
ARCHITECTURE DEMAREST
3/4"ø
C ARCHITECTURE DEMAREST, L.P.
ALL RIGHTS RESERVED
3
DATE
P104
07/16/12
Revision Schedule
No. Date
Description
HB-1
FIRE RISER.
2 1/2" DOMESTIC WATER
RPZ. REFER TO SECTION.
DCW RISER WITH ISOLATION VALVE PER
IPC CODE SECTION 606.1. REFER TO
UNIT PLANS AND RISER DIAGRAM FOR
MORE INFORMATION.
DCW RISER WITH ISOLATION VALVE PER
IPC CODE SECTION 606.1. REFER TO
UNIT PLANS AND RISER DIAGRAM FOR
MORE INFORMATION.
Plumbing Supply Plan Section A - Enlarged
A1
2
1/8" = 1'-0"
JOB NO.
10051
SHEET NO.
COPYRIGHT (C) 2011 ARCHITECTURE DEMAREST, L.P. ALL IDEAS, DESIGNS, ARRANGEMENTS, PLANS, AND SPECIFICATIONS INDICATED OR REPRESENTED BY THIS DRAWING AS INSTRUMENTS OF SERVICE ARE AND SHALL REMAIN THE EXCLUSIVE INTELLECTUAL PROPERTY OF ARCHITECTURE DEMAREST, L.P. AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THIS SPECIFIED PROJECT ONLY. NONE OF SUCH
IDEAS, DESIGN, ARRANGEMENTS OR PLANS SHALL BE USED ON ANY OTHER PROJECT OR EXTENSIONS OF THIS PROJECT OR USED BY OR DISCLOSED TO ANY PERSON, FIRM OR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION FORM AND APPROPRIATE COMPENSATION TO ARCHITECTUREDEMAREST, L.P. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. THE CONTRACTOR
SHALL BEAR SOLE RESPONSIBILITY FOR VERIFYING ALL DIMENSIONS ON THIS PROJECT AND NOTIFIYING ARCHITECTURE DEMAREST, L.P. OF ANY DEVIATIONS. THE CONTRACTOR SHALL BEAR SOLE RESPONSIBILITY FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, CONFIRMING COORDINATION AND FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT. ARCHITECTURE DEMAREST, L.P.
WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT.
P102
REFER TO CIVIL DRAWINGS
FOR CONTINUATION.
DW.REFR.
D
4"ø
4"ø
4"ø
3"ø
4"ø
4"ø
6"ø
6"ø
REFR.
W
DW.
W
D
D
REFR.
D
W
DW.
Sanitary Plan Section A - Enlarged A2
1/8" = 1'-0"
PERMIT SET
4" COMBINATION WATER AND FIRE
SPRINKLER LINE. REFER TO CIVIL
DRAWINGS FOR CONTINUATION.
DCW RISER WITH ISOLATION VALVE PER
IPC CODE SECTION 606.1. REFER TO
UNIT PLANS AND RISER DIAGRAM FOR
MORE INFORMATION.
DCW RISER WITH ISOLATION VALVE PER
IPC CODE SECTION 606.1. REFER TO
UNIT PLANS AND RISER DIAGRAM FOR
MORE INFORMATION.
HB-1
3/4"ø
3/4"ø
A
TRENT E BEIGHLE
DW.REFR.
W
DW.REFR.
W
R
LIC
SS
E NS ED IN
G
IONA L EN
PE-SERVICES
F-10841
EXP: 11/30/12
W
D
D
W
D
D
FE
O
W
W
W
PR
DW.
REFR.DW.
REFR.DW.
DW.REFR.
OF TE
TE
X
100821
REFR.DW.
DW.
TA
S
S
HB-1
EE
1
Plumbing Plan First Floor
Section A -A2
REFER TO RISER DIAGRAMS
FOR CONTINUATION OF
SANITARY RISERS. TYPICAL
Nacogdoches, TX
4"ø
3"ø
6"ø
REFR.DW.
DW.REFR.
DW.REFR.
REFR.DW.
W
W
D
D
DW.
D
REFR.
4"ø
CO
4"ø
4"ø
4"ø
3"ø
4"ø
4"ø
CO
4"ø
4"ø
6"ø
3"ø
4"ø
4"ø
4"ø
4"ø
4"ø
4"ø
3"ø
4"ø
4"ø
4"ø
3"ø
4"ø
CO
4"ø
4"ø
4"ø
4"ø
CO
6"ø
LUMBERJACK LOFTS
SFA 1411 ASSOCIATES, L.P.
W
D
W
DW.REFR.
W
D
4"ø
4"ø
D
6"ø
6"ø
W
W
3"ø
4"ø
4"ø
3"ø
4"ø
REFR.
4"ø
4"ø
3"ø
4"ø
WH
D
6"ø
W
D
CO
REFR.DW.
W
REFR.
D
6"ø
D
6"ø
W
CO
D
W
DW.
W
WH
REFR.DW.
DW.
REFR.DW.
DW.REFR.
6"ø
REFER TO RISER DIAGRAMS
FOR CONTINUATION OF
SANITARY RISERS. TYPICAL
1 1/4"ø
D
DW.
W
W
D
ARCHITECTURE DEMAREST
C ARCHITECTURE DEMAREST, L.P.
ALL RIGHTS RESERVED
DW.
DATE
W
3/4"ø
DW.REFR.
DW.REFR.
REFR.DW.
W
W
W
REFR.DW.
D
D
DW.
2"ø
REFR.
REFR.
REFR.
2 1/2"ø
2"ø
1 1/4"ø
1 1/4"ø
1 1/4"ø
07/16/12
D
D
2"ø
D
W
2"ø
1 1/2"ø
2 1/2"ø
1 1/4"ø
1 1/4"ø
REFR.
1 1/4"ø
WH
UP
D
REFR.
D
1 1/2"ø
W
1 1/4"ø
WH
D
D
1 1/4"ø
Revision Schedule
No. Date
Description
HB-1
FIRE RISER.
2 1/2" DOMESTIC WATER
RPZ. REFER TO SECTION.
DCW RISER WITH ISOLATION VALVE PER
IPC CODE SECTION 606.1. REFER TO
UNIT PLANS AND RISER DIAGRAM FOR
MORE INFORMATION.
DCW RISER WITH ISOLATION VALVE PER
IPC CODE SECTION 606.1. REFER TO
UNIT PLANS AND RISER DIAGRAM FOR
MORE INFORMATION.
DCW RISER WITH ISOLATION VALVE PER
IPC CODE SECTION 606.1. REFER TO
UNIT PLANS AND RISER DIAGRAM FOR
MORE INFORMATION.
Plumbing Supply Plan Section A - Enlarged
A2
2
1/8" = 1'-0"
COPYRIGHT (C) 2011 ARCHITECTURE DEMAREST, L.P. ALL IDEAS, DESIGNS, ARRANGEMENTS, PLANS, AND SPECIFICATIONS INDICATED OR REPRESENTED BY THIS DRAWING AS INSTRUMENTS OF SERVICE ARE AND SHALL REMAIN THE EXCLUSIVE INTELLECTUAL PROPERTY OF ARCHITECTURE DEMAREST, L.P. AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THIS SPECIFIED PROJECT ONLY. NONE OF SUCH
IDEAS, DESIGN, ARRANGEMENTS OR PLANS SHALL BE USED ON ANY OTHER PROJECT OR EXTENSIONS OF THIS PROJECT OR USED BY OR DISCLOSED TO ANY PERSON, FIRM OR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION FORM AND APPROPRIATE COMPENSATION TO ARCHITECTUREDEMAREST, L.P. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. THE CONTRACTOR
SHALL BEAR SOLE RESPONSIBILITY FOR VERIFYING ALL DIMENSIONS ON THIS PROJECT AND NOTIFIYING ARCHITECTURE DEMAREST, L.P. OF ANY DEVIATIONS. THE CONTRACTOR SHALL BEAR SOLE RESPONSIBILITY FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, CONFIRMING COORDINATION AND FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT. ARCHITECTURE DEMAREST, L.P.
WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT.
JOB NO.
10051
SHEET NO.
P103
Level 2 @ Section A
110' - 7 7/8"
REFER TO CIVIL DRAWINGS
FOR CONTINUATION.
Level 1 T.O.P. @ Section A
Level 2 @
Section
B
109'
- 1 1/8"
108' - 7 7/8"
3"ø
DW.REFR.
DW.REFR.
D
W
3"ø
Level 1 @ Section B
98' - 0"
D
3/4"ø
Level 1 @ Section A
100' - 0"
4"ø
2"ø
2"ø
1 1/4"ø
2"ø
4"ø
6"ø
4"ø
CO
3"ø
REFR.
DW.
DW.
4"ø
W
D
1 1/4"ø
4"ø
DCW RISER WITH ISOLATION VALVE PER
IPC CODE SECTION 606.1. REFER TO
UNIT PLANS AND RISER DIAGRAM FOR
MORE INFORMATION.
6"ø
Level 1 T.O.P. @ Section B
107' - 1 1/8"
WH
4"ø
2"ø
W
WH
Level 1 T.O.P. @ Section A
Level 2 @
Section
B
109'
- 1 1/8"
108' - 7 7/8"
D
W
Level 2 @ Section A
110' - 7 7/8"
1 1/4"ø
D
4"ø
DCW RISER WITH ISOLATION VALVE PER
IPC CODE SECTION 606.1. REFER TO
UNIT PLANS AND RISER DIAGRAM FOR
MORE INFORMATION.
PERMIT SET
3"ø
6"ø
D
W
6"ø
DW.
REFR.
REFR.
REFR.
DW.
HB-1
4"ø
REFER TO RISER DIAGRAMS
FOR CONTINUATION OF
SANITARY RISERS. TYPICAL
4"ø
REFR.
4"ø
W
D
S
R
PE-SERVICES
F-10841
EXP: 11/30/12
WH
REFR.
WH
DW.
DW.
4" COMBINATION
WATER AND FIRE
SPRINKLER LINE. REFER
TO CIVIL DRAWINGS FOR
CONTINUATION.
2 1/2"ø
4"ø
6"ø
E NS ED IN
G
IONA L EN
W
W
REFR.
4"ø
UP
ARCHITECTURE DEMAREST
C ARCHITECTURE DEMAREST, L.P.
ALL RIGHTS RESERVED
UP
FIRE RISER.
4"ø
2 1/2" DOMESTIC WATER
RPZ. REFER TO SECTION.
CO
Sanitary Plan Section A - Enlarged A3
1
1/8" = 1'-0"
SS
1 1/2"ø
D
3"ø
FE
LIC
2 1/2"ø
DCW RISER WITH ISOLATION VALVE PER
IPC CODE SECTION 606.1. REFER TO
UNIT PLANS AND RISER DIAGRAM FOR
MORE INFORMATION.
D
D
1 1/4"ø
6"ø
HB-1
4"ø
W
DCW RISER WITH ISOLATION VALVE PER
IPC CODE SECTION 606.1. REFER TO
UNIT PLANS AND RISER DIAGRAM FOR
MORE INFORMATION.
O
Combination Fire/Domestic Water Service
Entrance B
4
1/4" = 1'-0"
A
100821
PR
3/4"ø
4"ø
OF TE
TE
X
TRENT E BEIGHLE
1 1/4"ø
4"ø
D
TA
S
W
DW.
3"ø
D
DW.
W
REFR.
REFER TO RISER DIAGRAMS
FOR CONTINUATION OF
SANITARY RISERS. TYPICAL
2 1/2"ø
6"ø
Level 1 @ Section B
98' - 0"
3"ø
REFR.
CO
REFR.
Level 1 @ Section A
100' - 0"
DW.
DW.
4"ø
3/4"ø
EE
4"ø
4"ø
3"ø
3"
ø
6"ø
1 1/4"ø
DW.REFR.
D
D
6"ø
REFER TO RISER DIAGRAMS
FOR CONTINUATION OF
SANITARY RISERS. TYPICAL
W
W
Combination Fire/Domestic Water Service
Entrance A
3
1/4" = 1'-0"
REFR.DW.
REFR.DW.
DW.REFR.
4"ø
W
Nacogdoches, TX
6"ø
HB-1
LUMBERJACK LOFTS
SFA 1411 ASSOCIATES, L.P.
REFER TO RISER DIAGRAMS
FOR CONTINUATION OF
SANITARY RISERS. TYPICAL
Plumbing Plan First Floor
Section A -A3
Level 1 T.O.P. @ Section B
107' - 1 1/8"
DCW RISER WITH ISOLATION VALVE PER
IPC CODE SECTION 606.1. REFER TO
UNIT PLANS AND RISER DIAGRAM FOR
MORE INFORMATION.
4
4
P104
P104
DATE
07/16/12
Revision Schedule
No. Date
Description
Plumbing Supply Plan Section A - Enlarged
A3
2
1/8" = 1'-0"
JOB NO.
10051
SHEET NO.
COPYRIGHT (C) 2011 ARCHITECTURE DEMAREST, L.P. ALL IDEAS, DESIGNS, ARRANGEMENTS, PLANS, AND SPECIFICATIONS INDICATED OR REPRESENTED BY THIS DRAWING AS INSTRUMENTS OF SERVICE ARE AND SHALL REMAIN THE EXCLUSIVE INTELLECTUAL PROPERTY OF ARCHITECTURE DEMAREST, L.P. AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THIS SPECIFIED PROJECT ONLY. NONE OF SUCH
IDEAS, DESIGN, ARRANGEMENTS OR PLANS SHALL BE USED ON ANY OTHER PROJECT OR EXTENSIONS OF THIS PROJECT OR USED BY OR DISCLOSED TO ANY PERSON, FIRM OR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION FORM AND APPROPRIATE COMPENSATION TO ARCHITECTUREDEMAREST, L.P. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. THE CONTRACTOR
SHALL BEAR SOLE RESPONSIBILITY FOR VERIFYING ALL DIMENSIONS ON THIS PROJECT AND NOTIFIYING ARCHITECTURE DEMAREST, L.P. OF ANY DEVIATIONS. THE CONTRACTOR SHALL BEAR SOLE RESPONSIBILITY FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, CONFIRMING COORDINATION AND FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT. ARCHITECTURE DEMAREST, L.P.
WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT.
P104
W
WH
REFR.
DW.
UP
4
3"ø
MS-1
REF.
CO
WC-1
LV-1(2)
6"ø
UR-1
KS-2
2"ø
4"ø
WC-1
2"ø
LV-1(2)
KS-2
REF.
WC-1
6"ø
EWC-1
6"ø
4"ø
4"ø
DW.
Sanitary Plan Clubhouse Area - Enlarged
1/8" = 1'-0"
W
PERMIT SET
1
UP
Plumbing Plan First Floor
Clubhouse Area
WCO
Nacogdoches, TX
LUMBERJACK LOFTS
SFA 1411 ASSOCIATES, L.P.
P104
WH
REFR.
DW.
4" COMBINATION
WATER AND FIRE
SPRINKLER LINE. REFER
TO CIVIL DRAWINGS FOR
CONTINUATION.
UP
FIRE RISER.
TA
OF TE
TE
X
A
S
S
2 1/2" DOMESTIC WATER
RPZ. REFER TO SECTION.
4
TRENT E BEIGHLE
P104
O
FE
ROUTE 3/4" DCW AND
DHW TO WATER HEATER
AND ROUTE 3/4" DCW
DHW DOWN IN WALL TO
MOP SINK.
EE
PR
R
100821
LIC
SS
E NS ED IN
G
IONA L EN
PE-SERVICES
F-10841
EXP: 11/30/12
MS-1
REF.
ROUTE 1/2" DCW IN WALL
TO WALL BOX FOR ICE
MACKER.
ARCHITECTURE DEMAREST
WC-1
LV-1(2)
C ARCHITECTURE DEMAREST, L.P.
ALL RIGHTS RESERVED
UR-1
KS-2
WC-1
LV-1(2)
KS-2
EWC-1
Revision Schedule
No. Date
Description
REF.
WC-1
07/16/12
1 1/4"ø
1 1/4"ø
2"ø
ROUTE DCW AND DHW
DOWN IN CHASE TO
FIXTURES.
DATE
FIRE RISER.
2"ø
ROUTE DCW BELOW GRADE
TO POOL EQUIPMENT ROOM.
2 1/2" DOMESTIC WATER
RPZ. REFER TO SECTION.
ROUTE DCW DOWN TO
BELOW GRADE.
UP
DW.
2"ø
2 1/2"ø
4" COMBINATION
WATER AND FIRE
SPRINKLER LINE. REFER
TO CIVIL DRAWINGS FOR
CONTINUATION.
Plumbing Supply Plan Clubhouse Area Enlarged
2
1/8" = 1'-0"
COPYRIGHT (C) 2011 ARCHITECTURE DEMAREST, L.P. ALL IDEAS, DESIGNS, ARRANGEMENTS, PLANS, AND SPECIFICATIONS INDICATED OR REPRESENTED BY THIS DRAWING AS INSTRUMENTS OF SERVICE ARE AND SHALL REMAIN THE EXCLUSIVE INTELLECTUAL PROPERTY OF ARCHITECTURE DEMAREST, L.P. AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THIS SPECIFIED PROJECT ONLY. NONE OF SUCH
IDEAS, DESIGN, ARRANGEMENTS OR PLANS SHALL BE USED ON ANY OTHER PROJECT OR EXTENSIONS OF THIS PROJECT OR USED BY OR DISCLOSED TO ANY PERSON, FIRM OR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION FORM AND APPROPRIATE COMPENSATION TO ARCHITECTUREDEMAREST, L.P. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. THE CONTRACTOR
SHALL BEAR SOLE RESPONSIBILITY FOR VERIFYING ALL DIMENSIONS ON THIS PROJECT AND NOTIFIYING ARCHITECTURE DEMAREST, L.P. OF ANY DEVIATIONS. THE CONTRACTOR SHALL BEAR SOLE RESPONSIBILITY FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, CONFIRMING COORDINATION AND FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT. ARCHITECTURE DEMAREST, L.P.
WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT.
JOB NO.
10051
SHEET NO.
P105
W
6"ø
CO
4"ø
WH
DW
DW
PERMIT SET
Sanitary Plan Section B - Enlarged B1
1/8" = 1'-0"
Plumbing Plan First Floor
Section B -B1
REFER TO RISER DIAGRAMS
FOR CONTINUATION OF
SANITARY RISERS. TYPICAL
DCW RISER WITH ISOLATION VALVE PER
IPC CODE SECTION 606.1. REFER TO
UNIT PLANS AND RISER DIAGRAM FOR
MORE INFORMATION.
DCW RISER WITH ISOLATION VALVE PER
IPC CODE SECTION 606.1. REFER TO
UNIT PLANS AND RISER DIAGRAM FOR
MORE INFORMATION.
DCW RISER WITH ISOLATION VALVE PER
IPC CODE SECTION 606.1. REFER TO
UNIT PLANS AND RISER DIAGRAM FOR
MORE INFORMATION.
Nacogdoches, TX
3"ø
D
DW.
LUMBERJACK LOFTS
SFA 1411 ASSOCIATES, L.P.
REFR.
4"ø
4"ø
6"ø
3"ø
4"ø
4"ø
3"ø
3"ø
CO
W
3"ø
D
WH
4"ø
4"ø
4"ø
3"ø
D
W
4"ø
W
4"ø
3"ø
4"ø
4"ø
4"ø
3"ø
6"ø
REFR.
DW.
REFER TO CIVIL DRAWINGS
FOR CONTINUATION.
1
D
W
DN
DW.
REFR.DW.
6"ø
UP
D
4"ø
W
4"ø
REFR.
W
WH
4"ø
W
3"ø
4"ø
4"ø
3"ø
3"ø
4"ø
D
REFR.
CO
4"ø
REFR.
4"ø
3"ø
CO
DW.
REFR.
4"ø
4"ø
4"ø
REFR.
3"ø
4"ø
4"ø
4"ø
WH
D
3"ø
4"ø
CO
4"ø
3"ø
4"ø
6"ø
W
D
CO
D
W
REFR.
DW.
D
DW.
DW.
REF
R
REFER TO RISER DIAGRAMS
FOR CONTINUATION OF
SANITARY RISERS. TYPICAL
DCW RISER WITH ISOLATION VALVE PER
IPC CODE SECTION 606.1. REFER TO
UNIT PLANS AND RISER DIAGRAM FOR
MORE INFORMATION.
3/4"ø
TA
A
TRENT E BEIGHLE
DW.
DW.
SS
E NS ED IN
G
IONA L EN
PE-SERVICES
F-10841
EXP: 11/30/12
D
D
W
W
LIC
REF
R
O
DW.
EE
PR
R
100821
FE
DW.
OF TE
TE
X
S
S
HB-1
1 1/4"ø
W
REFR.
WH
REFR.
1 1/4"ø
1 1/4"ø
1 1/4"ø
WH
D
WH
REFR.
D
W
2"ø
W
REFR.
D
D
W
2 1/2"ø
DW.
DW.
REFR.
2"ø
D
W
WH
WH
1 1/4"ø
W
DW.
C ARCHITECTURE DEMAREST, L.P.
ALL RIGHTS RESERVED
DATE
07/16/12
DW
DW
3/4"ø
Revision Schedule
No. Date
Description
3/4"ø
2 1/2"ø
REFR.DW.
DN
W
ARCHITECTURE DEMAREST
D
REFR.
UP
D
1 1/4"ø
W
2 1/2"ø
1 1/4"ø
1 1/4"ø
REFR.
1 1/4"ø
D
1 1/2"ø
REFR.
HB-1
JOB NO.
HB-1
FIRE RISER.
Plumbing Supply Plan Section
- Enlarged
2 1/2"BDOMESTIC
WATER
RPZ. REFER TO SECTION.
B1
2
1/8" = 1'-0"
DCW RISER WITH ISOLATION VALVE PER
IPC CODE SECTION 606.1. REFER TO
UNIT PLANS AND RISER DIAGRAM FOR
MORE INFORMATION.
DCW RISER WITH ISOLATION VALVE PER
IPC CODE SECTION 606.1. REFER TO
UNIT PLANS AND RISER DIAGRAM FOR
MORE INFORMATION.
4" COMBINATION
WATER AND FIRE
COPYRIGHT (C) 2011 ARCHITECTURE DEMAREST, L.P. ALL IDEAS, DESIGNS, ARRANGEMENTS,
AND SPECIFICATIONS INDICATED OR REPRESENTED BY THIS DRAWING AS INSTRUMENTS OF SERVICE ARE AND SHALL REMAIN THE EXCLUSIVE INTELLECTUAL PROPERTY OF ARCHITECTURE DEMAREST, L.P. AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THIS SPECIFIED PROJECT ONLY. NONE OF SUCH
SPRINKLERPLANS,
LINE. REFER
IDEAS, DESIGN, ARRANGEMENTS OR PLANS SHALL BE USED ON ANY OTHER PROJECT
OR
EXTENSIONS
OF THIS PROJECT OR USED BY OR DISCLOSED TO ANY PERSON, FIRM OR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION FORM AND APPROPRIATE COMPENSATION TO ARCHITECTUREDEMAREST, L.P. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. THE CONTRACTOR
TO CIVIL DRAWINGS FOR
SHALL BEAR SOLE RESPONSIBILITY FOR VERIFYING ALL DIMENSIONS ON THIS PROJECT
AND NOTIFIYING ARCHITECTURE DEMAREST, L.P. OF ANY DEVIATIONS. THE CONTRACTOR SHALL BEAR SOLE RESPONSIBILITY FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, CONFIRMING COORDINATION AND FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT. ARCHITECTURE DEMAREST, L.P.
CONTINUATION.
WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT.
10051
SHEET NO.
P106
REF.
REF.
4"ø
UP
DW.
2 1/2"ø
D
1 1/4"ø
D
W
D
DCW RISER WITH ISOLATION VALVE PER
IPC CODE SECTION 606.1. REFER TO
UNIT PLANS AND RISER DIAGRAM FOR
MORE INFORMATION.
W
WH
2 1/2"ø
1 1/4"ø
4"ø
D
2"ø
REFR.
WH
3"ø
W
CO
3/4"ø
REFR.
D
3"ø
D
REFER TO RISER DIAGRAMS
FOR CONTINUATION OF
SANITARY RISERS. TYPICAL
4"ø
6"ø
W
DW.
1 1/4"ø
1 1/2"ø
DW.
REFER TO RISER DIAGRAMS
FOR CONTINUATION OF
SANITARY RISERS. TYPICAL
HB-1
6"ø
4"ø
REFR.
4"ø
REFR.
REFR.
3"ø
DW.
DW.
4"ø
3/4"ø
DCW RISER WITH ISOLATION VALVE PER
IPC CODE SECTION 606.1. REFER TO
UNIT PLANS AND RISER DIAGRAM FOR
MORE INFORMATION.
6"ø
4"ø
2"ø
4"ø
Plumbing Plan First FloorSection
B -B2
6"ø
DW.
REFR.
4"ø
3"ø
W
4" COMBINATION
WATER AND FIRE
SPRINKLER LINE. REFER
TO CIVIL DRAWINGS FOR
CONTINUATION.
Nacogdoches, TX
UP
4"ø
W
2 1/2" DOMESTIC WATER
RPZ. REFER TO SECTION.
LUMBERJACK LOFTS
SFA 1411 ASSOCIATES, L.P.
6"ø
2"ø
FIRE RISER.
HB-1
PERMIT SET
4"ø
4"ø
WH
W
W
WH
1 1/4"ø
D
D
CO
D
W
3"ø
S
DW.
FE
EE
R
100821
DW.
LIC
SS
E NS ED IN
G
IONA L EN
PE-SERVICES
F-10841
EXP: 11/30/12
H
W
WH
4"ø D
1 1/
4"ø
W
H
W
WH
1 1/4"ø
6"ø
3"ø
4"ø
D
W
A
CO
6"ø
4"ø
6"ø
OF TE
TE
X
TRENT E BEIGHLE
O
3"ø
REFR.
REFR.
1 1/4"ø
TA
PR
W
3"ø
D
DW.
DCW RISER WITH ISOLATION VALVE PER
IPC CODE SECTION 606.1. REFER TO
UNIT PLANS AND RISER DIAGRAM FOR
MORE INFORMATION.
S
DW.
4"ø
REFR.
REFR.
6"ø
2"ø
4"ø
R.
REF
R.
REF
DCW RISER WITH ISOLATION VALVE PER
IPC CODE SECTION 606.1. REFER TO
UNIT PLANS AND RISER DIAGRAM FOR
MORE INFORMATION.
4"ø
CO
D
W
D
DW
ARCHITECTURE DEMAREST
W
DW
C ARCHITECTURE DEMAREST, L.P.
ALL RIGHTS RESERVED
4"ø
6"ø
DATE
07/16/12
3"ø
DW REFR.
DW REFR.
Revision Schedule
No. Date
Description
REFER TO CIVIL DRAWINGS
FOR CONTINUATION.
Sanitary Plan Section B - Enlarged B2
1
1/8" = 1'-0"
Plumbing Supply Plan Section B - Enlarged
B2
2
1/8" = 1'-0"
JOB NO.
10051
SHEET NO.
COPYRIGHT (C) 2011 ARCHITECTURE DEMAREST, L.P. ALL IDEAS, DESIGNS, ARRANGEMENTS, PLANS, AND SPECIFICATIONS INDICATED OR REPRESENTED BY THIS DRAWING AS INSTRUMENTS OF SERVICE ARE AND SHALL REMAIN THE EXCLUSIVE INTELLECTUAL PROPERTY OF ARCHITECTURE DEMAREST, L.P. AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THIS SPECIFIED PROJECT ONLY. NONE OF SUCH
IDEAS, DESIGN, ARRANGEMENTS OR PLANS SHALL BE USED ON ANY OTHER PROJECT OR EXTENSIONS OF THIS PROJECT OR USED BY OR DISCLOSED TO ANY PERSON, FIRM OR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION FORM AND APPROPRIATE COMPENSATION TO ARCHITECTUREDEMAREST, L.P. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. THE CONTRACTOR
SHALL BEAR SOLE RESPONSIBILITY FOR VERIFYING ALL DIMENSIONS ON THIS PROJECT AND NOTIFIYING ARCHITECTURE DEMAREST, L.P. OF ANY DEVIATIONS. THE CONTRACTOR SHALL BEAR SOLE RESPONSIBILITY FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, CONFIRMING COORDINATION AND FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT. ARCHITECTURE DEMAREST, L.P.
WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT.
P107
4
P202
4
4
WC-1A
KS-1
3/4"ø
W
EWC-1
4
3
WB-1
EWC-1
5
1"ø
LV-1
2
1/2"ø
3/4"ø
1
3/4"ø
1"ø
2
EWC-1
1"ø
D
2
3/4"ø
3/4"ø
REFR.
IMB-1
1
1
1"ø
Unit A-1, A-1 Alt, and A-1 Alt-2 - Plumbing
Supply
1
1/4" = 1'-0"
Unit A-1-HC - Plumbing Supply
1/4" = 1'-0"
3
Unit B-1 and B-1 Alt - Plumbing Supply
1/4" = 1'-0"
PERMIT SET
2
LV-1
WC-1
5
IMB-1
4
KEYNOTES
1/2"ø
3/4"ø
3/4"ø
LV-2
4
1/2"ø
1/2"ø
DW.
D
1/2"ø
3/4"ø
1/2"ø
3/4"ø
LV-1
6
5
ROUTE 1/2" CW DOWN IN WALL TO ICE MACHINE BOX.
6
ROUTE 1/2" CW AND HW DOWN IN WALL TO BELOW
COUNTER. ROUTE PIPING BELOW COUNTER IN WALL TO
SINK.
A
TRENT E BEIGHLE
100821
FE
LIC
SS
E NS ED IN
G
IONA L EN
PE-SERVICES
F-10841
EXP: 11/30/12
4
DW
4
ROUTE 1/2" HW AND/OR CW DOWN IN WALL TO FIXTURE.
OF TE
TE
X
WB-1 3
1/2"ø
KS-1
4
TA
W
3/4"ø
D
W
3/4"ø
ROUTE 1/2" CW AND HW DOWN IN WALL TO WASHER BOX.
O
1/2"ø
3/4"ø
3
PR
1"ø
EWC-1
3/4"ø
2
WC-1
MOUNT WATER HEATER ON SELF ABOVE DRYER FOR UNITS
A-1(HC), B-1(HC), B-2 AND B-3. FOR UNIT D-1
MOUNT WATER HEATER ON FLOOR. REFER TO DETAIL SHEET
FOR MORE INFORMATION.
S
REFR.
4
2
4
BT-1
3
WB-1
WATER SUPPLY RISER.
KS-1
5 IMB-1
1
1
REFR.
R
4
S
4
Nacogdoches, TX
DW
3/4"ø
4
KS-1
D
WB-1
3
3/4"ø
WB-1
3/4"ø
4
EE
3/4"ø
3/4"ø
1/2"ø
4
1/2"ø
1/2"ø
3
1/2"ø
LV-1
4
1/2"ø
3/4"ø
1/2"ø
5
D
KS-1
IMB-1
DW.
4
W
4
1/2"ø
WC-1
W
DW.
1/2"ø
1/2"ø
LV-2
4
1/2"ø
IMB-1
LV-1
BT-1
6
REFR.
REFR.
5
WC-1
BT-1A
WC-1
3/4"ø
1/2"ø
BT-1
LUMBERJACK LOFTS
SFA 1411 ASSOCIATES, L.P.
BT-1
4
Plumbing Typical
Room Plans
4
GENERAL NOTES
1. REFER TO RISER DRAWINGS FOR ADDITIONAL PIPE SIZES AND
ROUTING.
BT-1A
1"ø
4
WC-1A
2. SLOPE HORIZONTAL DRAINAGE PIPING MINIMUM 1/8" PER FOOT.
1
3/4"ø
4
2
EWC-1
ARCHITECTURE DEMAREST
3/4"ø
BT-1
C ARCHITECTURE DEMAREST, L.P.
ALL RIGHTS RESERVED
DATE
LV-1
4
07/16/12
Revision Schedule
No. Date
Description
WC-1
4
BT-1
4
JOB NO.
Unit B-1-HC - Plumbing Supply
4
1/4" = 1'-0"
Unit B-2 - Plumbing Supply
6
1/4" = 1'-0"
10051
SHEET NO.
COPYRIGHT (C) 2011 ARCHITECTURE DEMAREST, L.P. ALL IDEAS, DESIGNS, ARRANGEMENTS, PLANS, AND SPECIFICATIONS INDICATED OR REPRESENTED BY THIS DRAWING AS INSTRUMENTS OF SERVICE ARE AND SHALL REMAIN THE EXCLUSIVE INTELLECTUAL PROPERTY OF ARCHITECTURE DEMAREST, L.P. AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THIS SPECIFIED PROJECT ONLY. NONE OF SUCH
IDEAS, DESIGN, ARRANGEMENTS OR PLANS SHALL BE USED ON ANY OTHER PROJECT OR EXTENSIONS OF THIS PROJECT OR USED BY OR DISCLOSED TO ANY PERSON, FIRM OR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION FORM AND APPROPRIATE COMPENSATION TO ARCHITECTUREDEMAREST, L.P. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. THE CONTRACTOR
SHALL BEAR SOLE RESPONSIBILITY FOR VERIFYING ALL DIMENSIONS ON THIS PROJECT AND NOTIFIYING ARCHITECTURE DEMAREST, L.P. OF ANY DEVIATIONS. THE CONTRACTOR SHALL BEAR SOLE RESPONSIBILITY FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, CONFIRMING COORDINATION AND FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT. ARCHITECTURE DEMAREST, L.P.
WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT.
P200
UP
BT-1
UP
4
ø
3/4"
ø
1/2"
WC-1
4
4
P202
P202
4
BT-1
LV-1
9
ø
3/4"
W
3/4"ø
LV-1
7
3/4"ø
1"ø
D
3/4"ø
LV-1
KS-1
2
EWC-1
1"ø
WB-1
ø
3/4"
DW.
2
1/2"ø
IMB-1 5
1
LV-1
4
4
3
Unit B-3 Upper Level - Plumbing Supply
1/4" = 1'-0"
1/2"ø
1/2"ø
REFR.
1/2"ø
1/2"ø
1/2"ø
1/2"ø
KS-1
Unit B-3 Lower Level - Plumbing Supply
1/4" = 1'-0"
WC-1
4
BT-1
GENERAL NOTES
KEYNOTES
Unit B-2 Alt - Plumbing Supply
1/4" = 1'-0"
1. REFER TO RISER DRAWINGS FOR ADDITIONAL PIPE SIZES AND
ROUTING.
1
WATER SUPPLY RISER.
2
MOUNT WATER HEATER ON SELF ABOVE DRYER FOR UNITS A-1
(HC), B-1(HC), B-2 AND B-3. FOR UNIT D-1 MOUNT
WATER HEATER ON FLOOR. REFER TO DETAIL SHEET FOR MORE
INFORMATION.
3
ROUTE 1/2" CW AND HW DOWN IN WALL TO WASHER BOX.
4
ROUTE 1/2" HW AND/OR CW DOWN IN WALL TO FIXTURE.
5
ROUTE 1/2" CW DOWN IN WALL TO ICE MACHINE BOX.
6
ROUTE 1/2" CW AND HW DOWN IN WALL TO BELOW COUNTER.
ROUTE PIPING BELOW COUNTER IN WALL TO SINK.
7
ROUTE 1/2" HW AND/OR CW DOWN IN WALL TO FIXTURES AND
UP TO FIXTURES ON UPPER LEVEL.
8
ROUTE PIPING IN FLOOR JOIST SPACE OF STAIRS.
9
1/2" HW AND/OR CW FROM BELOW TO FIXTURES.
2. SLOPE HORIZONTAL DRAINAGE PIPING MINIMUM 1/8" PER FOOT.
WB-1 3
EWC-1 2
1
TA
OF TE
TE
X
A
S
IMB-1 5
S
3/4"ø
PERMIT SET
3/4"ø
4
Plumbing Typical
Room Plans
ø
3/4"
1
Nacogdoches, TX
LUMBERJACK LOFTS
SFA 1411 ASSOCIATES, L.P.
7
1/2"ø
WB-1 3
W
3
9
WC-1
9
ø
3/4"
EWC-1
BT-1
WC-1
3/4"ø
ø
3/4"
D
2
3/4"ø
1/2"ø
8
DW.
6
1
3/4"ø
REFR.
ø
3/4"
5
IMC-1
3/4"ø
7
TRENT E BEIGHLE
4
4
3/4"ø
4
1"ø
3/4"ø
4
SS
E NS ED IN
G
IONA L EN
PE-SERVICES
F-10841
EXP: 11/30/12
1/2"ø
4
3/4"ø
LIC
4
1"ø
LV-1
4
1/2"ø
O
FE
EE
R
100821
WH
WH
W
D
PR
REFR.
LV-1
3/4"ø
4
DW
4
3/4"ø
LV-2
WC-1
1"ø
WC-1A
4
KS-1
1"ø
LV-1
WC-1
1 1/4"ø
3/4"ø
WC-1
6
BT-1
4
4
BT-1A
ARCHITECTURE DEMAREST
4
BT-1
BT-1
1/2"ø
3/4"ø
WC-1
BT-1
6
WC-1
3/4"ø
BT-1
1 1/4"ø
LV-1
1"ø
LV-1
BT-1
WC-1
WC-1
1"ø
3/4"ø
07/16/12
LV-1
4
3/4"ø
4
KS-1
1"ø
1"ø
1 1/4"ø
4
Revision Schedule
No. Date
Description
4
1"ø
4
4
1"ø
BT-1
DATE
DW.
1"ø
C ARCHITECTURE DEMAREST, L.P.
ALL RIGHTS RESERVED
LV-1
2
EWC-1
1
WH
W
D
5
WB-1
REFR.
3
WB-1
4
Unit D-1 - Plumbing Supply
1/4" = 1'-0"
JOB NO.
10051
5
Unit D-1-HC - Plumbing Supply
1/4" = 1'-0"
COPYRIGHT (C) 2011 ARCHITECTURE DEMAREST, L.P. ALL IDEAS, DESIGNS, ARRANGEMENTS, PLANS, AND SPECIFICATIONS INDICATED OR REPRESENTED BY THIS DRAWING AS INSTRUMENTS OF SERVICE ARE AND SHALL REMAIN THE EXCLUSIVE INTELLECTUAL PROPERTY OF ARCHITECTURE DEMAREST, L.P. AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THIS SPECIFIED PROJECT ONLY. NONE OF SUCH
IDEAS, DESIGN, ARRANGEMENTS OR PLANS SHALL BE USED ON ANY OTHER PROJECT OR EXTENSIONS OF THIS PROJECT OR USED BY OR DISCLOSED TO ANY PERSON, FIRM OR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION FORM AND APPROPRIATE COMPENSATION TO ARCHITECTUREDEMAREST, L.P. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. THE CONTRACTOR
SHALL BEAR SOLE RESPONSIBILITY FOR VERIFYING ALL DIMENSIONS ON THIS PROJECT AND NOTIFIYING ARCHITECTURE DEMAREST, L.P. OF ANY DEVIATIONS. THE CONTRACTOR SHALL BEAR SOLE RESPONSIBILITY FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, CONFIRMING COORDINATION AND FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT. ARCHITECTURE DEMAREST, L.P.
WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT.
SHEET NO.
P201
Tower Wall @ Section B
144' - 6"
Level 4 T.O.Q
142' - 11 1/4"
T.O.Parapet 3 @ Section A
142' - 4"
Level 4 T.O.P
141' - 0 3/4"
T.O.
T.O.Parapet
Parapet 3
2 @ Section B
A
140' - 4"
4
1
SANITARY RISER.
2
VENT RISER.
3
COMBINATION SANITARY AND VENT RISER.
P202
Level 4
131' - 11 5/8"
1
GENERAL NOTES
WC-1
REFR.
2. SLOPE HORIZONTAL DRAINAGE PIPING MINIMUM 1/8" PER
FOOT.
LV-1
Level 3 T.O.P. @ Section B
128' - 4 7/8"
DW.
2
WB-1 3
W
KS-1
3
1. REFER TO ISOMETRIC DRAWINGS FOR ADDITIONAL INFORMATION.
1
BT-1 3
Level 3 T.O.P. @ Section A
130' - 4 7/8"
D
Nacogdoches, TX
KEYNOTES
LUMBERJACK LOFTS
SFA 1411 ASSOCIATES, L.P.
T.O.Parapet 1 @ Section A
T.O. Parapet 2 @ Section
B
138' - 7"
138' - 4"
Level 2 T.O.P. @ Section A
119' - 9"
Level 3 @ Section
B
119' - 3 3/4"
Level 2 Tower Sanitary Plan
1/4" = 1'-0"
Level 2 T.O.P. @ Section B
117' - 9"
B. O. Roof @ Club House
Courtyard Entrance
113' - 5"
UP
UP
PERMIT SET
1
Plumbing Typical
Tower Sanitary
Plans
B. O. Roof @ Club House
Entrance
Level Main
3 @ Section
A
121'
121' -- 4
3 3/4"
3/4"
Level 2 @ Section A
110' - 7 7/8"
P202
Level 1 T.O.P. @ Section A
109'
- 1 1/8"
Level 2 @
Section
B
108' - 7 7/8"
TA
OF TE
TE
X
A
S
P202
S
4
4
TRENT E BEIGHLE
Level 1 T.O.P. @ Section B
107' - 1 1/8"
1
FE
O
1
EE
PR
R
100821
BT-1
LIC
SS
E NS ED IN
G
IONA L EN
BT-1
PE-SERVICES
F-10841
EXP: 11/30/12
REFR.
WC-1
WC-1
2
2
1
DW.
1
LV-1
LV-1
W
3
WB-1 3
2
2
D
Level 1 @ Section A
100' - 0"
KS-1
ARCHITECTURE DEMAREST
C ARCHITECTURE DEMAREST, L.P.
ALL RIGHTS RESERVED
Level 1 @ Section B
98' - 0"
DATE
08/10/12
Revision Schedule
No. Date
Description
2
Level 3 Tower Sanitary Plan
1/4" = 1'-0"
3
Level 4 Tower Sanitary Plan
1/4" = 1'-0"
JOB NO.
Tower Room Section
4
3/8" = 1'-0"
COPYRIGHT (C) 2011 ARCHITECTURE DEMAREST, L.P. ALL IDEAS, DESIGNS, ARRANGEMENTS, PLANS, AND SPECIFICATIONS INDICATED OR REPRESENTED BY THIS DRAWING AS INSTRUMENTS OF SERVICE ARE AND SHALL REMAIN THE EXCLUSIVE INTELLECTUAL PROPERTY OF ARCHITECTURE DEMAREST, L.P. AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THIS SPECIFIED PROJECT ONLY. NONE OF SUCH
IDEAS, DESIGN, ARRANGEMENTS OR PLANS SHALL BE USED ON ANY OTHER PROJECT OR EXTENSIONS OF THIS PROJECT OR USED BY OR DISCLOSED TO ANY PERSON, FIRM OR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION FORM AND APPROPRIATE COMPENSATION TO ARCHITECTUREDEMAREST, L.P. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. THE CONTRACTOR
SHALL BEAR SOLE RESPONSIBILITY FOR VERIFYING ALL DIMENSIONS ON THIS PROJECT AND NOTIFIYING ARCHITECTURE DEMAREST, L.P. OF ANY DEVIATIONS. THE CONTRACTOR SHALL BEAR SOLE RESPONSIBILITY FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, CONFIRMING COORDINATION AND FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT. ARCHITECTURE DEMAREST, L.P.
WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT.
10051
SHEET NO.
P202
WATER METER
(IF REQUIRED)
SHUT-OFF VALVE
(IF REQUIRED)
BACKFLOW
PREVENTER
SEE SCHEDULE
CLEAN-OUT AND ACCESS
COVER. TOP OF COVER
TO BE FLUSH WITH TOP
OF FLOOR
WATER TO BUILDING
AIR GAP
MAY EXTEND AS
WASTE OR VENT
FINISHED GRADE
FOR WALL
CONSTRUCTION REFER
TO ARCHITECTURAL DWGS.
FLOOR
CLEANOUT PLUG
COUNTERSUNK
SCREW
POLISHED S.S. ACCESS
COVER
C.I. CLEANOUT
TEE
16" SQUARE CONCRETE PAD
TROWEL SMOOTH AND BEVEL
EDGES
1/8 C.I. BEND
12" MIN.
30" MAX.
BRASS CLEAN-OUT PLUG WITH
COUNTER SUNK HEAD
FLOOR
COORD W/WALL FINISH
1/8 C.I. BEND
EARTH
1/ "
8
BEND AND
END OF LINE
CLEANOUT
WASTE LINE
DIRECTION OF FLOW
2
WCO
Cleanouts Details
12" = 1'-0"
PIPE HANGER NEXT TO ELBOW
FROM CW SUPPLY
TO HEATER, NO
INTERVENING VALVES
3/ "DHW
4
3/ "DCW
4
HW
WELDED STEEL EXPANSION
TANK WITH POLYPROPYLENE
LINING, FDA APPROVED FOR
DOMESTIC WATER SERVICE
INSULATE ALL PIPING
IN ACCORDANCE WITH
SPECIFICATIONS.
CW
PIPE UNION:
DIELECTRIC
IF REQUIRED FOR
DISSIMILAR METALS
INSULATE ALL PIPING
IN ACCORDANCE WITH
SPECIFICATIONS.
UNION BY P.C. (TYP.)
WATER HEATER SEE
PLUMBING FIXTURE
SCHEDULE FOR
ADDITIONAL INFO.
3/4"T & P RELIEF
VALVE BY P.C.
5
BUTYL DIAPHRAGM
VERIFY WITH LOCAL
CODES IF/WHEN TRAP
AND/OR VENT ARE
REQUIRED FOR THE LENGTH
OF DRAIN PIPE INSTALLED
ROUTE PIPE INCONSPICUOUSLY AND UNOBTRUSIVELY.
HANG
PIPE AS REQUIRED. DO NOT INSULATE INDIRECT DRAIN PIPE
WHEN INSTALLED EXPOSED IN FOOD SERVICE FACILITY. REFER
TO LOCAL CODES FOR FURTHER INFORMATION.
SECURELY ATTACH DRAIN PIPE TO EQUIPMENT (PREFERRED),
OR TO FLOOR IN AN APPROVED MANNER TO PREVENT DRAIN
PIPE FROM BEING SHIFTED OR DAMAGED.
Expansion Tank Detail
12" = 1'-0"
7
Indirect Condesate Drain Detail
1/4" = 1'-0"
3/4" RUN FULL SIZE
TO FLOOR DRAIN
SHUT-OFF VALVE IN
ACCESSIBLE LOCATION
ABOVE CEILING
DRAIN VALVE BY P.C.
DRAIN PAN WITH
DRAIN FULL SIZE TO FLOOR
DRAIN W/ APPROVED AIR GAP
TO DRAIN.
PROVIDE APPROVED AIR GAP
SHELF AND SUPPORT
BRACKETS BY GENERAL
CONTRACTOR.
FLOOR
FLASHING AND COUNTERFLASHING OF VTR IS
BY ROOFING CONTRACTOR
CEILING
INSTALL RISER INSIDE
PARTITION WHERE
AVAILABLE; REFER TO
PLANS. IF RISER IS
EXPOSED, ANCHOR
TIGHT TO WALL, INTERIOR
TO WALL INSULATION
ELBOW AS REQUIRED
CORE DRILL OR PROVIDE
SLEEVE IF REQUIRED
BY TYPE OF ROOF DECK
LENGTH OF SHAFT TO
SUIT THICKNESS OR WALL
CUT WALL AS REQUIRED.
INSTALL WALL HYDRANT,
GROUT OR OTHERWISE
REPAIR WALL NEATLY
AROUND FACE OF WALL
HYDRANT, TO SEAL
WATERTIGHT
ANCHOR PIPE TO ROOF DECK
OR JOISTS WITH U-BOLT AROUND
PIPE AND ANGLE IRON WELDED
OR SCREWED TO DECK OR JOIST
ROOF INSULATION
MINIMUM 12" BELOW ROOF
FWH-1
TA
OF TE
TE
X
A
TRENT E BEIGHLE
ROOF DECK
PROVIDE PIPE INCREASER
WHERE REQUIRED TO MAKE
MINIMUM 3" VENT THRU ROOF
100821
FE
O
Electric Water Heater Detail - Floor Mounted
12" = 1'-0"
MINIMUM 30" ABOVE ROOF
NORMALLY. EXTEND TO HEIGHT
OF PARAPET WHEN WITHIN TEN
FEET OF PARAPET
S
4
EXTERIOR BUILDING WALL
PR
Electric Water Heater - Wall Mounted
12" = 1'-0"
WHA
PDI
SIZE "A"
INSULATE COLD WATER PIPE
FLOOR DRAIN
OR MOP SINK.
LIC
SS
E NS ED IN
G
IONA L EN
PE-SERVICES
F-10841
EXP: 11/30/12
HUBLESS PIPE CONNECTORS ON
CAST IRON PIPE
VALVE INTERIOR TO WALL
INTERIOR FLOOR
LAVATORY
HANG PIPE LARGER THAN
4" FROM TOP OF JOISTS
ONLY AT PANEL POINT
WOOD STRUCTURE
SIDE BEAM CONNECTOR
ATTACHED TO TOP
CHORD OF WOOD TRUSS
ALL-THREAD ROD
COPPER PIPE
HANGER SPACING
STEEL PIPE
HANGER SPACING
1/2"
6'
6'
3/4"
6'
6'
1"
6'
8'
1-1/4"
6'
10'
1-1/2"
6'
10'
2"
10'
10'
2-1/2"
10'
10'
3"
10'
10'
4"
10'
10'
8
COVER VALVE BODIES WITH
INSULATION, BUT NOT UNIONS
REFER TO PLANS FOR VTR PIPE SIZES AND LOCATIONS. LOCATE VTR MINIMUM
THREE FEET FROM PROPERTY LINE, OR TEN FEET HORIZONTAL OR THREE FEET
VERTICAL ABOVE ANY BUILDING OPENING OR FRESH AIR INTAKE, OR ONE FOOT
FROM ANY VERTICAL SURFACE. LOCATE VTR MINIMUM 18" FROM PARAPET,
EXPANSION JOINT, EQUIPMENT CURB, ETC. OFFSET IN CEILING SPACE WHERE
REQUIRED TO MEET THESE CONDITIONS.
11
TAPE JOINTS OF
FIBERGLASS INSULATION
6
PROVIDE COPPER
COATED HANGERS
WHERE HANGERS
CONTACT BARE
COPPER PIPE
Freezeproof Wall Hydrant Detail
1/4" = 1'-0"
Vent Thru Roof Detail
12" = 1'-0"
ARCHITECTURE DEMAREST
C ARCHITECTURE DEMAREST, L.P.
ALL RIGHTS RESERVED
1/ "DHW
2
PROVIDE GALVANIZED STEEL SHIELD FOR
ALL INSULATED PIPE. VERIFY INSULATION
THICKNESS WHEN SIZING HANGERS AND SHIELDS
PROVIDE ONE-PIECE
PREMOULDED PVC
FITTING COVERS (TYP)
PROVIDE UPPER ATTACHMENT AS REQUIRED FOR CASES NOT SHOWN
HERE. DO NOT INSTALL HANGER INSIDE INSULATION OR OTHERWISE
PENETRATE VAPOR BARRIER. DO NOT HANG ONE PIPE FROM ANOTHER
EXCEPT IN CHASES. SLOPE ALL WATER PIPING SLIGHTLY TOWARD
DRAINABLE LOCATIONS.
HANGER SPACING FOR PIPE SIZES: AS
INDICATED IN TABLE. CAST IRON: 10' AND WITHIN 1'-0" OF ALL JOINTS.
ROD SIZES FOR PIPE SIZE: 2" AND SMALLER=3/8", 2 1/2" TO 3"=1/2",
4"=5/8". LOCATE HANGERS WITHIN 1'-0" OF VALVES AND FITTINGS.
PROVIDE SUPPLEMENTAL STEEL STRUTS BETWEEN JOISTS IF REQUIRED.
LOCATE HANGERS WITHIN 1'-0" OF EQUIPMENT CONNECTIONS. ANCHOR
WATER PIPE AGAINST SWAYING DUE TO CHANGES IN WATER VELOCITY.
CHAINS AND PERFORATED STRAP IRON AND STEEL ARE NOT ACCEPTABLE.
DO NOT SUSPEND PIPE FROM JOIST BRACING MEMBERS. REFER TO CODES
AND SPECIFICATIONS FOR FURTHER INFORMATION. PROVIDE SEISMIC
BRACING IF/AS REQUIRED BY LOCAL AUTHORITIES.
Pipe Hangers Details
1/4" = 1'-0"
INSTALL 18" ABOVE
GRADE. ADJUST HEIGHT
IF/AS REQUIRED TO
SUIT MASONRY JOINTS
EXTERIOR GRADE,
PAVEMENT, OR
OR SIDEWALK
REFER TO OTHER DETAILS FOR TREATMENT
OF INSULATION AT PENETRATION OF WALLS
ADJUSTABLE BAND HANGER
FOR PIPE 3-1/2" AND
SMALLER AND CAST IRON
PIPE 2" AND SMALLER
PIPE SIZE
3
MAKE PIPE MINIMUM ONE SIZE
LARGER THAN EQUIPMENT
CONNECTION, MINIMUM 3/4".
USE "M" OR "L" HARD COPPER
UP TO 1" AND DWV COPPER
FOR 1-1/4" AND LARGER
PIPING ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT
FIELD CONDITIONS. MAKE PIPE SAME SIZE AS TANK FITTING.
FOLLOW MANUFACTURER'S INSTRUCTIONS FOR INSTALLATION
PROCEDURE. VERIFY PROPER OPERATION WHEN INSTALLED.
3/4"T & P RELIEF
VALVE BY P.C.
DRAIN PAN WITH
DRAIN FULL SIZE TO FLOOR
DRAIN OR MOP SINK
W/ APPROVED AIR GAP
DRAIN VALVE BY P.C.
WATER HEATER SEE
PLUMBING FIXTURE
SCHEDULE FOR
ADDITIONAL INFO.
EXPANSION TANK
TO FLOOR DRAIN OR
MOP SINK W/ APPROVED AIR GAP
FILL TANK WITH AIR
PRESSURE TO MATCH
WATER PRESSURE,
THEN OPEN VALVE
DISCHARGE INTO RECEPTOR
WITH AIR GAP SUFFICIENT TO
REMOVE GRATE AND STRAINER.
MINIMUM GAP = TWICE PIPE
DIAMETER
S
EXPANSION TANK
EXP-1
PROVIDE CLEANOUTS IN
TURNS/ENDS OF PIPE.
USE DWV FITTINGS IF SIZE
IS LARGER THAN 1"
SLOPE PIPE
CD
AS MUCH AS
POSSIBLE
TOWARD
DISCHARGE
ID
MAKE CONNECTION
TO EQUIPMENT
AS REQUIRED
R
Backflow Preventer Detail
12" = 1'-0"
GCO
PERMIT SET
1
FCO
Plumbing Details
WATER SERVICE
FLOW
EE
1/'8" BEND IF CLEAN-OUT OCCURS AT
END OF LINE.
Nacogdoches, TX
LUMBERJACK LOFTS
SFA 1411 ASSOCIATES, L.P.
C.I. WASTE LINE. LENGTH AS REQUIRED
WASTE PIPING
PROVIDE ELASTOMERIC
OR FIBERGLASS INSULATION
ON DOMESTIC COLD AND
HOT WATER PIPES IN
WALLS AND CHASES. SEAL
ALL JOINTS WITH ADHESIVE
ASSE 1070
MIXING VALVE
PROVIDE A ONE
FOOT LENGTH OF
NONCOMPRESSIBLE
INSULATION AT
HANGERS FOR ALL
PIPE 2-1/2" AND
LARGER
INTEGRAL COMPRESSION
FITTINGS (TYP)
DATE
07/16/12
ANGLE VALVE
SEAL TIGHT AT
BREEZEWAY
WALL
1/ "DCW
2
POINT-OF-USE
WATER HEATER
REFER TO SCHEDULE
FOR SIZE(S)
LEAVE OPEN FOR
COMMUNICATION
HEAT TO WET PIPE
Revision Schedule
No. Date
Description
INSULATION
WET PIPE
SUPPLY
PVC TUBE
TRUSS
HEATED AREA
PROVIDE FIBERGLASS INSULATION WITH ALL-SERVICE JACKET WITH VAPOR
BARRIER ON ALL SIZES OF HOT AND COLD WATER AND CONDENSATE PIPING.
REFER TO SPECIFICATIONS FOR FURTHER INFORMATION REGARDING INSULATION.
INSTALL ALL ITEMS PER SPECIFICATIONS AND MANUFACTURER'S INSTRUCTIONS.
MAINTAIN VAPOR BARRIER ON COLD PIPING BY MEANS OF SEALANT AND TAPE.
FLAME-SPREAD AND SMOKE-DEVELOPED INDEXES SHALL NOT EXCEED 25/50.
SEAL EXPOSED ENDS OF FIBERGLASS INSULATION WITH ADHESIVE MASTIC.
9
Pipe Insulation Detail
12" = 1'-0"
12
10
BREEZEWAY NON-HEATED AREA
HEATED AREA
Wet Pipe Breezway Freeze Protection Detail
12" = 1'-0"
Point-of-Use Water Heater Detail
12" = 1'-0"
COPYRIGHT (C) 2011 ARCHITECTURE DEMAREST, L.P. ALL IDEAS, DESIGNS, ARRANGEMENTS, PLANS, AND SPECIFICATIONS INDICATED OR REPRESENTED BY THIS DRAWING AS INSTRUMENTS OF SERVICE ARE AND SHALL REMAIN THE EXCLUSIVE INTELLECTUAL PROPERTY OF ARCHITECTURE DEMAREST, L.P. AND WERE CREATED, EVOLVED AND DEVELOPED FOR USE ON AND IN CONNECTION WITH THIS SPECIFIED PROJECT ONLY. NONE OF SUCH
IDEAS, DESIGN, ARRANGEMENTS OR PLANS SHALL BE USED ON ANY OTHER PROJECT OR EXTENSIONS OF THIS PROJECT OR USED BY OR DISCLOSED TO ANY PERSON, FIRM OR ANY PURPOSE WHATSOEVER WITHOUT THE WRITTEN PERMISSION FORM AND APPROPRIATE COMPENSATION TO ARCHITECTUREDEMAREST, L.P. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. THE CONTRACTOR
SHALL BEAR SOLE RESPONSIBILITY FOR VERIFYING ALL DIMENSIONS ON THIS PROJECT AND NOTIFIYING ARCHITECTURE DEMAREST, L.P. OF ANY DEVIATIONS. THE CONTRACTOR SHALL BEAR SOLE RESPONSIBILITY FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, CONFIRMING COORDINATION AND FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT. ARCHITECTURE DEMAREST, L.P.
WILL NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THIS PROJECT.
JOB NO.
10051
SHEET NO.
P300