LUMARK
DESCRIPTION
S P E C I F I C AT I O N F E AT U R E S
The BenchMark HB utilizes a
durable heavy-duty die-cast
aluminum ballast housing and
computer aided designed
reflector system for
specification-level
performance at mounting
heights above 20'. U.L. listed
and CSA certified. Damp
location standard.
A ...M o u n t i n g
D ...S o c k e t
Easy slide-on die-cast
aluminum mounting box with
tapped opening for 3/4" conduit.
Mogul-base porcelain socket.
A P P L I C AT I O N
The BenchMark HB is perfect
for high-bay applications such
as gymnasiums, hangars,
manufacturing, assembly and
auto service areas.
B ...H o u s i n g
Durable heavy-duty die-cast
aluminum housing for lasting
performance in the harshest
environments. Integrally
hinged for ease of
maintenance with optional
toolless entry. Finished in a
white polyester powder coat.
C ...B a l l a s t
High power factor ballast
with class H insulation. U.L.
listed for 65°C (149°F) ambient
temperature operation.
Minimum starting temperature
is -40°C (-40°F) for HPS and
-30°C (-20°F) for MH. CSA
certified.
E ...U n i v e r s a l B r a c k e t s
Universal ladder brackets
allow for the flexibility to
change out with other
reflectors available in acrylic
or glass.
F ...R e f l e c t o r
Computer aided designed,
field-adjustable reflector
mounts easily and allows
multiple distribution patterns
for precise control. Special
contours and unique system
of facets result in a maximum
voltage rise of 4.2 volts.
HBHIGH-BAY
BENCHMARK
1 7 5 - 1 0 0 0 W
High Pressure Sodium
Metal Halide
DIE-CAST ALUMINUM
H I G H - B AY
H E AV Y- D U T Y I N D U S T R I A L
LUMINAIRE
A
B
C
Maximum height with 18"
reflector is 29 3/16" [741mm].
Maximum height with 23"
reflector is 32 13/16" [833mm].
See ordering information
for more details.
D
E
E N E R G Y D AT A
CWI Ballast Input Watts
250W HPS HPF (300 Watts)
250W MH HPF (300 Watts)
400W HPS HPF (465 Watts)
400W MH HPF (475 Watts)
ADH990713
C
COOPER LIGHTING
YS
ER
T EM
S
S
23" [584mm]
18" [457mm]
CWA Ballast Input Watts
175W MH HPF (210 Watts)
250W MH HPF (295 Watts)
320W MP HPF (365 Watts)
350W MP HPF (395 Watts)
400W MP HPF (448 Watts)
400W HPS HPF (465 Watts)
400W MH HPF (455 Watts)
600W HPS HPF (665 Watts)
750W HPS HPF (850 Watts)
1000W HPS HPF (1100 Watts)
1000W MH HPF (1085 Watts)
D
F
TIFIE
®
H B B E N C H M A R K H I G H - B AY
PHOTOMETRICS
90°
Coefficients Of Utilization
Effective floor cavity reflectance
rc
80%
70%
rw
70 50 30 10
70 50 30 10
RCR
1
93 90 88 85
91 88 86 84
2
87 82 78 74
85 80 76 73
3
81 74 69 64
79 72 67 63
4
75 67 61 56
73 66 60 56
5
69 60 54 49
67 59 53 49
6
64 54 47 43
62 53 47 42
7
58 48 41 36
57 47 41 36
8
54 43 36 32
52 42 36 31
9
49 38 32 32
48 38 31 27
10
45 34 28 23
44 34 27 23
5
7
9
60°
11
13
30°
15
CP/1000
M H S S - S A1 8 - W - 4 0 0
400-Watt MH
36,000-Lumen Clear Lamp
Spacing Criterion
1.6
Zone
%Lamp
Zone
0-30
22.60
0-90
0-40
44.70
90-180
0-60
77.10
Total
20%
50%
50 30 10
30%
50 30 10
10%
50 30 10
84
77
69
63
57
51
45
41
36
32
80
73
67
61
55
49
44
39
35
31
76
70
64
58
53
48
42
38
34
30
82
73
65
58
52
46
40
35
31
27
80
71
62
54
48
42
36
31
27
23
78
71
63
57
50
44
39
34
30
26
77
68
60
53
47
41
35
30
26
22
75
68
61
55
49
43
38
33
29
26
%Lamp
80.10
4.40
84.40
74
66
59
52
46
40
35
30
26
22
0%
0
72
65
57
51
44
39
33
28
24
21
Candlepower
Degree CP
0
9725
5
8934
15
8131
25
10678
35
12926
45
9338
55
5204
65
844
75
109
85
10
90
1
95
2
105
6
115
11
125
30
135
85
145
1296
155
1286
165
132
175
35
180
33
O R D E R I N G I N F O R M AT I O N
S A M P L E N U M B E R : H P H B - S A1 8 - M - 4 0 0 - M T- Q
HB SA
Lamp Type
Reflector Type
HP=High
SA=Anodized
Pressure
Spun
Sodium
Aluminum
MH=Metal
Reflector
Halide
Diameter
MP=Pulse
15=15"
Start MH
18=18"
(CWA) 6
23=23"
ML=Pulse
Start MH
(Linear
Reactor) 6, 7, 12, 13
Socket Position/
Distribution
C=Conc.
M=Medium
W=Wide
Lamp
Wattage
175=175W
200=200W 4
250=250W
320=320W 4
350=350W 4
400=400W
600=600W 8
1000=1000W 2
Voltage 3
120V
208V
240V
277V
347V
480V
TT=TripleTap1
MT=MultiTap 1
Series
HB=High-Bay
Benchmark
Catalog
Number 1
18" Reflector
HPHB-SA18-C-250
HPHB-SA18-M-250
HPHB-SA18-W-250
HPHB-SA18-C-400
HPHB-SA18-M-400
HPHB-SA18-W-400
MHHB-SA18-C-400
MHHB-SA18-M-400
MHHB-SA18-W-400
23" Reflector
HPHB-SA23-C-1000
HPHB-SA23-M-1000
HPHB-SA23-W-1000
MHHB-SA23-C-1000
MHHB-SA23-M-1000
MHHB-SA23-W-1000
Lamp
Type/Base
Lamp
Wattage S/MH Distribution
Net Wt.
(lbs.)
HPS/Mogul
HPS/Mogul
HPS/Mogul
HPS/Mogul
HPS/Mogul
HPS/Mogul
MH/Mogul
MH/Mogul
MH/Mogul
250
250
250
400
400
400
400
400
400
1.0
1.4
1.6
1.0
1.4
1.6
0.9
1.2
1.6
Concentrated
Medium
Wide
Concentrated
Medium
Wide
Concentrated
Medium
Wide
20.5
20.5
20.5
28.5
28.5
28.5
24.5
24.5
24.5
HPS/Mogul
HPS/Mogul
HPS/Mogul
MH/Mogul
MH/Mogul
MH/Mogul
1000
1000
1000
1000
1000
1000
0.6
1.3
1.9
0.9
1.3
1.9
Concentrated
Medium
Wide
Concentrated
Medium
Wide
33.5
33.5
33.5
33.5
33.5
33.5
NOTES: (1) Multi-Tap ballast is 120/208/240/277V wired 277V. Triple-Tap ballast is 120/277/347V
wired 347V. Add desired voltage before “MT” or “TT”.
(2)
Standard 55°C ambient environments.
(3)
Products also available in non-US voltages and 50Hz for international markets.
Consult factory for availability and ordering information.
(4)
Pulse-Start MH only.
(5)
Available in 250 & 400W Metal Halide 120/277V only.
(6)
175, 200, 250, 320, 350, & 400W only.
(7)
277V only, not available with Q or EM option.
(8)
HPS only.
(9)
Factory set for concentrated, medium or wide distribution otherwise fixture is shipped
in medium setting for 18" reflector.
(10)
30 Second time delay when switching from bright to dim above 400W. Consult
individual lamp manufacturers recommendations for compatible lamps. For use with
CWA ballast only.
(11)
Not available with QD, PC3, C3, PHC or MWS.
(12)
Not available with HL or HC.
(13)
Must specify “OR” open rated socket or safety glass bottom enclosure.
Options (add as suffix)
F1=Single Fuse—120, 277 or 347V
(Specify single voltage only)
F2=Double Fused—208, 240 or 480V
(Specify single voltage only)
Q=Quartz Restrike DC Bayonet Base
(Hot strike only)
QD=Quick Disconnect Die-Cast Pendant
Mount Box—Specify single voltage
(Not compatible with PC3, PHC, C3,
MWS or HC)
RM=Remote Mount
P=Pre-set socket position from Factory.
Specify desired position 9
PS=Protective Starter
TE=Toolless Entry
EM=Quartz Restrike with “Delay Relay”–
Housing Mounted (Strikes at cold start)
EM/SC=Emergency Separate Circuit–
Reflector Mounted 12
SCF=3' Aircraft Safety Cable–Housing to
ceiling
SCR=Aircraft Safety Cable–Housing to
reflector
SS=Space Saver Feature
MWS=Modular Wiring Systems Available.
Consult Factory
DL100=100% Downlight
QB=Quiet Ballast 5
LL=Lamp Included
TW=Thru-way Mounting Box
HL=LumaWatt Fixture Control Module
(Allows low voltage control wire to be
daisey-chained between fixtures outside
AC conduit run similar to low voltage
intercoms, fire alarms and phone
systems) 10
HC=LumaWatt Fixture Control Module
(Low voltage leads pulled out of top
connection box for areas requiring all
wiring to be installed in conduit) 10, 11
OR=Open rated socket for pulse start Metal
Halide
Accessories (order separately)
FH-1=Fixture Hook
FL-1=Fixture Loop
SHK=Hook with Safety Screw
PC3=3' Cord for with NEMA Plugs (120V-L5-15P,
208V-L6-15P, 240V-L6-15P, 277V-L7-15P,
347V-L37-20P and 480V-L8-20P) Other Lengths
Available. Requires FH-1 or FL-1. Use with
TPPH-NEMA. Specify Voltage
PHC=Power Cord and Plug (18" cord, non-NEMA plug
requires FL-1 and TPPH)
TPPH-NEMA=Thru-way Pendant Power Hook.
Requires FL-1 and PC3. Specify Voltage
(18" cord, non-NEMA plug, FL-1
required)
TPPH=Thru-Way Pendant Power Hook Requires
FL-1 and PHC. Specify Voltage
TPPH-NEMA=Thru-Way Pendant Power Hook
Requires FL-1 and PC3. Specify Voltage
TPPH-F=Thru-Way Pendant Power Hook–Single Fuse,
120, 277 or 347 Volt. Requires FL-1 and PHC.
Specify Voltage
TPPH-F2=Thru-Way Pendant Power Hook–Double
Fused, 208, 240 or 480 Volt. Requires FL-1
and PHC. Specify Voltage
TPPH-F-QD=Thru-Way Pendant Power Hook–Single
Fuse, Quick Disconnect. Requires FL-1
and PHC. Specify Voltage
TPPH-F2-QD=Thru-Way Pendant Power Hook–Double
Fused, Quick Disconnect. Requires FL-1
and PHC. Specify Voltage
WG15=Wire Guard for 15"
(not compatible with SGB15)
WG18=Wire Guard for 18"
(not compatible with SGB18)
WG23=Wire Guard for 23"
(not compatible with SGB23)
WG15/GLC=Gym Wire Guard w/ Safety Glass for 15"
WG18/GLC=Gym Wire Guard w/ Safety Glass for 18"
WG23/GLC=Gym Wire Guard w/ Safety Glass for 23"
C3=3' Cord-No Plug-Requires FH-1 or FL-1
MBT=Twin Mount Bracket (Fixtures must be same
voltage and without hooks, loops or plugs)
SGB15=Safety Glass Bottom for 15"
(not compatible with WG15)
SGB18=Safety Glass Bottom for 18"
(not compatible with WG18)
SGB23=Safety Glass Bottom for 23"
(not compatible with WG23)
NOTE: Specifications and Dimensions subject to change without notice.