LUMARK DESCRIPTION S P E C I F I C AT I O N F E AT U R E S The BenchMark HB utilizes a durable heavy-duty die-cast aluminum ballast housing and computer aided designed reflector system for specification-level performance at mounting heights above 20'. U.L. listed and CSA certified. Damp location standard. A ...M o u n t i n g D ...S o c k e t Easy slide-on die-cast aluminum mounting box with tapped opening for 3/4" conduit. Mogul-base porcelain socket. A P P L I C AT I O N The BenchMark HB is perfect for high-bay applications such as gymnasiums, hangars, manufacturing, assembly and auto service areas. B ...H o u s i n g Durable heavy-duty die-cast aluminum housing for lasting performance in the harshest environments. Integrally hinged for ease of maintenance with optional toolless entry. Finished in a white polyester powder coat. C ...B a l l a s t High power factor ballast with class H insulation. U.L. listed for 65°C (149°F) ambient temperature operation. Minimum starting temperature is -40°C (-40°F) for HPS and -30°C (-20°F) for MH. CSA certified. E ...U n i v e r s a l B r a c k e t s Universal ladder brackets allow for the flexibility to change out with other reflectors available in acrylic or glass. F ...R e f l e c t o r Computer aided designed, field-adjustable reflector mounts easily and allows multiple distribution patterns for precise control. Special contours and unique system of facets result in a maximum voltage rise of 4.2 volts. HBHIGH-BAY BENCHMARK 1 7 5 - 1 0 0 0 W High Pressure Sodium Metal Halide DIE-CAST ALUMINUM H I G H - B AY H E AV Y- D U T Y I N D U S T R I A L LUMINAIRE A B C Maximum height with 18" reflector is 29 3/16" [741mm]. Maximum height with 23" reflector is 32 13/16" [833mm]. See ordering information for more details. D E E N E R G Y D AT A CWI Ballast Input Watts 250W HPS HPF (300 Watts) 250W MH HPF (300 Watts) 400W HPS HPF (465 Watts) 400W MH HPF (475 Watts) ADH990713 C COOPER LIGHTING YS ER T EM S S 23" [584mm] 18" [457mm] CWA Ballast Input Watts 175W MH HPF (210 Watts) 250W MH HPF (295 Watts) 320W MP HPF (365 Watts) 350W MP HPF (395 Watts) 400W MP HPF (448 Watts) 400W HPS HPF (465 Watts) 400W MH HPF (455 Watts) 600W HPS HPF (665 Watts) 750W HPS HPF (850 Watts) 1000W HPS HPF (1100 Watts) 1000W MH HPF (1085 Watts) D F TIFIE ® H B B E N C H M A R K H I G H - B AY PHOTOMETRICS 90° Coefficients Of Utilization Effective floor cavity reflectance rc 80% 70% rw 70 50 30 10 70 50 30 10 RCR 1 93 90 88 85 91 88 86 84 2 87 82 78 74 85 80 76 73 3 81 74 69 64 79 72 67 63 4 75 67 61 56 73 66 60 56 5 69 60 54 49 67 59 53 49 6 64 54 47 43 62 53 47 42 7 58 48 41 36 57 47 41 36 8 54 43 36 32 52 42 36 31 9 49 38 32 32 48 38 31 27 10 45 34 28 23 44 34 27 23 5 7 9 60° 11 13 30° 15 CP/1000 M H S S - S A1 8 - W - 4 0 0 400-Watt MH 36,000-Lumen Clear Lamp Spacing Criterion 1.6 Zone %Lamp Zone 0-30 22.60 0-90 0-40 44.70 90-180 0-60 77.10 Total 20% 50% 50 30 10 30% 50 30 10 10% 50 30 10 84 77 69 63 57 51 45 41 36 32 80 73 67 61 55 49 44 39 35 31 76 70 64 58 53 48 42 38 34 30 82 73 65 58 52 46 40 35 31 27 80 71 62 54 48 42 36 31 27 23 78 71 63 57 50 44 39 34 30 26 77 68 60 53 47 41 35 30 26 22 75 68 61 55 49 43 38 33 29 26 %Lamp 80.10 4.40 84.40 74 66 59 52 46 40 35 30 26 22 0% 0 72 65 57 51 44 39 33 28 24 21 Candlepower Degree CP 0 9725 5 8934 15 8131 25 10678 35 12926 45 9338 55 5204 65 844 75 109 85 10 90 1 95 2 105 6 115 11 125 30 135 85 145 1296 155 1286 165 132 175 35 180 33 O R D E R I N G I N F O R M AT I O N S A M P L E N U M B E R : H P H B - S A1 8 - M - 4 0 0 - M T- Q HB SA Lamp Type Reflector Type HP=High SA=Anodized Pressure Spun Sodium Aluminum MH=Metal Reflector Halide Diameter MP=Pulse 15=15" Start MH 18=18" (CWA) 6 23=23" ML=Pulse Start MH (Linear Reactor) 6, 7, 12, 13 Socket Position/ Distribution C=Conc. M=Medium W=Wide Lamp Wattage 175=175W 200=200W 4 250=250W 320=320W 4 350=350W 4 400=400W 600=600W 8 1000=1000W 2 Voltage 3 120V 208V 240V 277V 347V 480V TT=TripleTap1 MT=MultiTap 1 Series HB=High-Bay Benchmark Catalog Number 1 18" Reflector HPHB-SA18-C-250 HPHB-SA18-M-250 HPHB-SA18-W-250 HPHB-SA18-C-400 HPHB-SA18-M-400 HPHB-SA18-W-400 MHHB-SA18-C-400 MHHB-SA18-M-400 MHHB-SA18-W-400 23" Reflector HPHB-SA23-C-1000 HPHB-SA23-M-1000 HPHB-SA23-W-1000 MHHB-SA23-C-1000 MHHB-SA23-M-1000 MHHB-SA23-W-1000 Lamp Type/Base Lamp Wattage S/MH Distribution Net Wt. (lbs.) HPS/Mogul HPS/Mogul HPS/Mogul HPS/Mogul HPS/Mogul HPS/Mogul MH/Mogul MH/Mogul MH/Mogul 250 250 250 400 400 400 400 400 400 1.0 1.4 1.6 1.0 1.4 1.6 0.9 1.2 1.6 Concentrated Medium Wide Concentrated Medium Wide Concentrated Medium Wide 20.5 20.5 20.5 28.5 28.5 28.5 24.5 24.5 24.5 HPS/Mogul HPS/Mogul HPS/Mogul MH/Mogul MH/Mogul MH/Mogul 1000 1000 1000 1000 1000 1000 0.6 1.3 1.9 0.9 1.3 1.9 Concentrated Medium Wide Concentrated Medium Wide 33.5 33.5 33.5 33.5 33.5 33.5 NOTES: (1) Multi-Tap ballast is 120/208/240/277V wired 277V. Triple-Tap ballast is 120/277/347V wired 347V. Add desired voltage before “MT” or “TT”. (2) Standard 55°C ambient environments. (3) Products also available in non-US voltages and 50Hz for international markets. Consult factory for availability and ordering information. (4) Pulse-Start MH only. (5) Available in 250 & 400W Metal Halide 120/277V only. (6) 175, 200, 250, 320, 350, & 400W only. (7) 277V only, not available with Q or EM option. (8) HPS only. (9) Factory set for concentrated, medium or wide distribution otherwise fixture is shipped in medium setting for 18" reflector. (10) 30 Second time delay when switching from bright to dim above 400W. Consult individual lamp manufacturers recommendations for compatible lamps. For use with CWA ballast only. (11) Not available with QD, PC3, C3, PHC or MWS. (12) Not available with HL or HC. (13) Must specify “OR” open rated socket or safety glass bottom enclosure. Options (add as suffix) F1=Single Fuse—120, 277 or 347V (Specify single voltage only) F2=Double Fused—208, 240 or 480V (Specify single voltage only) Q=Quartz Restrike DC Bayonet Base (Hot strike only) QD=Quick Disconnect Die-Cast Pendant Mount Box—Specify single voltage (Not compatible with PC3, PHC, C3, MWS or HC) RM=Remote Mount P=Pre-set socket position from Factory. Specify desired position 9 PS=Protective Starter TE=Toolless Entry EM=Quartz Restrike with “Delay Relay”– Housing Mounted (Strikes at cold start) EM/SC=Emergency Separate Circuit– Reflector Mounted 12 SCF=3' Aircraft Safety Cable–Housing to ceiling SCR=Aircraft Safety Cable–Housing to reflector SS=Space Saver Feature MWS=Modular Wiring Systems Available. Consult Factory DL100=100% Downlight QB=Quiet Ballast 5 LL=Lamp Included TW=Thru-way Mounting Box HL=LumaWatt Fixture Control Module (Allows low voltage control wire to be daisey-chained between fixtures outside AC conduit run similar to low voltage intercoms, fire alarms and phone systems) 10 HC=LumaWatt Fixture Control Module (Low voltage leads pulled out of top connection box for areas requiring all wiring to be installed in conduit) 10, 11 OR=Open rated socket for pulse start Metal Halide Accessories (order separately) FH-1=Fixture Hook FL-1=Fixture Loop SHK=Hook with Safety Screw PC3=3' Cord for with NEMA Plugs (120V-L5-15P, 208V-L6-15P, 240V-L6-15P, 277V-L7-15P, 347V-L37-20P and 480V-L8-20P) Other Lengths Available. Requires FH-1 or FL-1. Use with TPPH-NEMA. Specify Voltage PHC=Power Cord and Plug (18" cord, non-NEMA plug requires FL-1 and TPPH) TPPH-NEMA=Thru-way Pendant Power Hook. Requires FL-1 and PC3. Specify Voltage (18" cord, non-NEMA plug, FL-1 required) TPPH=Thru-Way Pendant Power Hook Requires FL-1 and PHC. Specify Voltage TPPH-NEMA=Thru-Way Pendant Power Hook Requires FL-1 and PC3. Specify Voltage TPPH-F=Thru-Way Pendant Power Hook–Single Fuse, 120, 277 or 347 Volt. Requires FL-1 and PHC. Specify Voltage TPPH-F2=Thru-Way Pendant Power Hook–Double Fused, 208, 240 or 480 Volt. Requires FL-1 and PHC. Specify Voltage TPPH-F-QD=Thru-Way Pendant Power Hook–Single Fuse, Quick Disconnect. Requires FL-1 and PHC. Specify Voltage TPPH-F2-QD=Thru-Way Pendant Power Hook–Double Fused, Quick Disconnect. Requires FL-1 and PHC. Specify Voltage WG15=Wire Guard for 15" (not compatible with SGB15) WG18=Wire Guard for 18" (not compatible with SGB18) WG23=Wire Guard for 23" (not compatible with SGB23) WG15/GLC=Gym Wire Guard w/ Safety Glass for 15" WG18/GLC=Gym Wire Guard w/ Safety Glass for 18" WG23/GLC=Gym Wire Guard w/ Safety Glass for 23" C3=3' Cord-No Plug-Requires FH-1 or FL-1 MBT=Twin Mount Bracket (Fixtures must be same voltage and without hooks, loops or plugs) SGB15=Safety Glass Bottom for 15" (not compatible with WG15) SGB18=Safety Glass Bottom for 18" (not compatible with WG18) SGB23=Safety Glass Bottom for 23" (not compatible with WG23) NOTE: Specifications and Dimensions subject to change without notice. Visit our web site at www.cooperlighting.com Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 ADH990713