NEW! LIGHTING CONTROLS EMERGENCY UL924 BYPASS/ SHUNT RELAYS ELCU-200 DESCRIPTION The ELCU-200 Emergency Lighting Control Unit is a selfcontained device that allows any standard lighting control device to control emergency lighting in conjunction with normal lighting in any area within a building. If power is lost for any reason, including the tripping of a single branch circuit breaker, the ELCU-200 will force on the emergency fixtures for that area. The ELCU-200 can be wired either as a control device, so that emergency lighting follows the control of normal lighting, or as a bypass device to shunt emergency power around a control device (e.g., a dimmer) when normal power fails. FEATURES LIGHITING CONTROLS 11 • Eliminates energy waste caused by emergency lighting that is always on • Integral push-to-test button activates emergency mode for a true test condition • Connects to EMTS-100 Remote Test Switch or other input to activate emergency on from a remote location • Operates as a control device or as a shunt • Senses local single circuit power failure • Zero cross switching technology for reliability and increased product life • Compatible with WattStopper occupancy sensors, daylighting controls, lighting control panels, and dimmers • LED indication for emergency and normal power • Half-second delayed on positively identifies emergency fixtures for required maintenance • Provides absolute fail-to-on emergency lighting • Qualifies for use on ARRA-funded projects ELCU-200 SPECIFICATIONS Supply Voltage Supply Frequency Maximum Load Ballast Incandescent Motor Activation Dimensions 120/277 VAC 60 Hz 20A @ 120/277 VAC 10A @ 120 VAC 1HP @ 120 VAC Supplies 24 VDC source for dry contact closure. Push-to-test button on unit. Operating Temperature32° to 131°F (0° to 55°C) Operating Humidity 5 to 95%, noncondensing 668 888-397-5353 USA kele.com Housing Type Approvals Weight Warranty 1.7"H x 2.97"W x 1.64"D (43.2mm x 75.4mm x 41.7mm) with a 1/2" (12.7mm) threaded nipple Fire rated V-0, 176°F (80°C) UL Listed, cUL listed for Emergency Lighting and Power, E302768 Meets NEC, OSHA, and NFPA safety codes; UL 2043 plenum rated 0.44 lb (0.2 kg) 5 years WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE. March 2014 NEW! LIGHTING CONTROLS EMERGENCY UL924 BYPASS/ SHUNT RELAYS ELCU-200 WIRING Wiring for a Shunt or Bypass Device Normal Line Normal Lighting Dimmer Normal Neutral Normal Power Sense Emergency Neutral Emergency Power Out Normal Power Cir.#_______ 09 86 Cap Cut Jumper Loop to use with normally closed - Test switch - Fire alarm panel - Security panel - Other 0r 1 Emergency Power Circle CUT-OUT R 8 m .5 m Push to Test EMERGENCY CIRCUIT Emergency Line “Always On” Normal Neutral Normal Switch Sense Remote Activation Emergency Power In Emergency Lighting Dimmer Emergency Neutral When wired as a shunt, the switching line is not used. Note: Use with WattStopper universal dimmers or contact dimmer manufacturer to determine the suitablity of the specified dimmer for shunt operation. 11 Wiring for a Control Device Normal Neutral Normal Power Sense Emergency Power In Emergency Neutral Emergency Power Out Cir.#_______ 09 0r 1 Emergency Power Normal Power 86 Remote Activation Circle CUT-OUT R 8 m .5 m Push to Test EMERGENCY CIRCUIT Normal Lighting Normal Neutral LIGHTING CONTROLS Control Device Normal Line Normal Switch Sense Cut Jumper Loop to use with normally closed - Test switch - Fire alarm panel - Security panel - Other Emergency Lighting Emergency Line “Always On” Emergency Neutral When wired as a control device, the ELCU-200 receives a switching signal from the output of the control device (relay, switch, power pack, etc.) ORDERING INFORMATION March 2014 MODEL ELCU-200 ELCU-200-U DESCRIPTION Emergency Lighting Control Unit Emergency Lighting Control unit, ARRA- compliant EMTS-100 ACCESSORIES Remote test switch on single gang plate, 24 VDC, normally closed contact WE MAKE IT EASY. kele.com 888-397-5353 USA 669