CLEAN-TRAK TOP-LOAD FLUSH CEILING SYSTEM CLEANPAK's cleanroom filtered ceiling system with continuous grid in both directions features powder coated extruded aluminum grid channels, integrated lighting, integrated sprinkler system, associated connectors, grid hanging all-thread rod from grid to turnbuckle, filters, and accessories such as filter dampers, blank pans, return air grilles, clips, and miscellaneous hanging hardware and clips for wall head track and grid face hanging support. The system enables up to full filter coverage by moving the lighting out of the grid opening and placing it in a linear grid channel. It allows full flexibility in cleanroom, wall, equipmment, and track layouts. Filters and components can be top loaded or loaded from the bottom by tipping the component through the grid opening. The ceiling fully integrates with air movement devices for complete systems like fan tunnel systems with RAHs on top of plenum, remote RAHs ducted to filters in grid, remote RAHs pressurizing interstitial, end blower modules, vertical side blower modules, or FFUs in grid or plenum. KEY FEATURES Flush ceiling grid module. Extruded aluminum top-load grid. Welded modules up to 8x24 foot for rapid field installation. Optional stick-built grid. Integral lighting--T8, T5, or LED. Integral fire protection. A true flush concealed sprinkler head can be used in the grid extrusion. Clean-Screens for washing out particles under grid channel. Optional GelLink seal that flows between modules for leak-free module to module joints. Optional integrated ionization wiring. Option to be walkable on the filters, FFUs, or blank pans. Optional Equalizer can be used to balance the ceiling filters. Optional plenum can. CONDENSED SPECIFICATION optional items noted in [ ] The grid [plenum] system shall be the Clean-Trak top-load flush as manufactured by CLEANPAK. The cleanroom filtered ceiling system shall consist of a continuous ceiling grid with powder coated extruded aluminum grid channel, integrated lighting, integrated sprinkler system, associated connectors, grid hanging all-thread rod from grid to turnbuckle, nominal 2x4 foot [4x4 foot] filters, and accessories such as filter dampers, blank pans, return air grilles, clips, and miscellaneous hanging hardware and clips for wall head track, grid face hanging, and piping. The ceiling grid shall have a top trough to accept gel in the field for a leak-free seal of components. [The ceiling system shall have gasket on the top for a non-pressurized interstitial application.] [The ceiling system shall also include a positively pressurized plenum that is an integral part of the ceiling grid. The ceiling grid for plenums is required to have gel seals for sealing the filters to the grid. Gasketed seals between filter and grid for positively pressurized plenums are not allowed.] [The plenum shall have a series of fans installed in the roof to provide for airflow through the system.] The grid extrusion shall have integrated flush lighting within the grid channel that is capable of 100% filter coverage of the entire ceiling. The grid extrusion shall be capable of accepting a true flush sprinkler head within the width of the extrusion. [The grid shall have a GelLink seal that flows gel between module joints.] [The grid shall have Clean-Screens at the grid face that have perimeter slots to jet air underneath the grid member and wash out the area of particles.] CES Group, LLC CLEANPAK | 19855 SW 124th Ave, Tualatin, OR 97062 | 503.639.0113 | www.huntair.com THIS DRAWING IS THE PROPERTY OF HUNTAIR CLEANPAK AND CAN NOT BE REPRODUCED IN WHOLE OR IN PART, NOR DELIVERED TO OTHERS WITHOUT THE EXPRESS WRITTEN PERMISSION OF HUNTAIR CLEANPAK. FILE NAME: DRAWN BY: Jon H ISSUED ON: 08/07/13 CLEANPAK a CES Group Brand TITLE: 19855 SW 124th AVE. TUALATIN, OR 97062 Phone (503) 639-0113 www.huntair.com 2.6 TOP LOAD MASTER TOP ISO CHECKED BY: ZC SCALE: 2.6TopLoad.idw 1/32 SIZE: B JOB NO: DRAWING NO.: SHEET 2 OF 35 AE AE AD AC AD A N AC AH A N E P G E G Y P F R AH AB F AA AB Y AA R H T H K K C T C D D AF AF AG AG B U B U M V M V J J W W L AJ AL L AJ AL AT AM AT AM AR AK AK AN AN AR AP AP THIS DRAWING IS THE PROPERTY OF HUNTAIR CLEANPAK AND CAN NOT BE REPRODUCED IN WHOLE OR IN PART, NOR DELIVERED TO OTHERS WITHOUT THE EXPRESS WRITTEN PERMISSION OF HUNTAIR CLEANPAK. FILE NAME: DRAWN BY: Jon H ISSUED ON: 08/07/13 CLEANPAK a CES Group Brand TITLE: 19855 SW 124th AVE. TUALATIN, OR 97062 Phone (503) 639-0113 www.huntair.com 2.6 TOP LOAD MASTER PLAN VIEW CHECKED BY: ZC SCALE: 2.6TopLoad.idw 3/32 SIZE: E JOB NO: DRAWING NO.: SHEET 3 OF 35 ITEM 5.500 STOCK NUMBER DESCRIPTION QTY 1 240-10-24 Extr 2.6 Int Gel TB 2 240-10-25 Extr 2.6 Int Gel 3 240-10-33 Extr 2.6 Int GSK TB 4 240-10-66 Extr 2.6 Ext Gel Link Perim 5 240-10-67 Extr 2.6 Ext Gel Link Plen RVT 6 240-10-41 Extr 2.6 Ext Gskt 5.500 4.225 3.365 2.625 2.625 2.600 2.600 2.600 1 2 3 8.460 8.000 8.000 7.610 5.050 5.050 2.625 2.625 1.300 1.300 4 5 6 THIS DRAWING IS THE PROPERTY OF HUNTAIR CLEANPAK AND CAN NOT BE REPRODUCED IN WHOLE OR IN PART, NOR DELIVERED TO OTHERS WITHOUT THE EXPRESS WRITTEN PERMISSION OF HUNTAIR CLEANPAK. FILE NAME: DRAWN BY: Jon H ISSUED ON: 08/07/13 CLEANPAK a CES Group Brand TITLE: 19855 SW 124th AVE. TUALATIN, OR 97062 Phone (503) 639-0113 www.huntair.com 2.6 TOP LOAD GRID EXTRUSION PROFILES CHECKED BY: ZC SCALE: 2.6TopLoad.idw 3/8 SIZE: A JOB NO: DRAWING NO.: SHEET 4 OF 35 1" SCH 40 PIPE (BY OTHERS) TYPE "B" COUPLING THREADED 1" FEMALE EIGHT LUG LOCKING NUT MIRAGE CONCEALED SPRINKLER SECTION A-A SCALE 1 / 2 THIS DRAWING IS THE PROPERTY OF HUNTAIR CLEANPAK AND CAN NOT BE REPRODUCED IN WHOLE OR IN PART, NOR DELIVERED TO OTHERS WITHOUT THE EXPRESS WRITTEN PERMISSION OF HUNTAIR CLEANPAK. FILE NAME: DRAWN BY: Jon H ISSUED ON: 08/08/13 CLEANPAK a CES Group Brand TITLE: CHECKED BY: ZC 19855 SW 124th AVE. TUALATIN, OR 97062 Phone (503) 639-0113 www.huntair.com 2.6 TOP LOAD GRID SPRINKLER CONCEALED HARD PIPED TYPE "B" COUPLING SCALE: 2.6TopLoad.idw 1/2 SIZE: A JOB NO: DRAWING NO.: SHEET 5 OF 35 1" SCH 40 PIE (BY OTHERS) TYPE "M" COUPLING THREADED 1" FEMALE EIGHT LUG LOCKING NUT SPRINKLER HEAD (INSTALLED BY OTHERS) SECTION B-B SCALE 1 / 2 THIS DRAWING IS THE PROPERTY OF HUNTAIR CLEANPAK AND CAN NOT BE REPRODUCED IN WHOLE OR IN PART, NOR DELIVERED TO OTHERS WITHOUT THE EXPRESS WRITTEN PERMISSION OF HUNTAIR CLEANPAK. FILE NAME: DRAWN BY: Jon H ISSUED ON: 08/08/13 CLEANPAK a CES Group Brand TITLE: 19855 SW 124th AVE. TUALATIN, OR 97062 Phone (503) 639-0113 www.huntair.com 2.6 TOP LOAD GRID SPRINKLER PENDANT HARD PIPED TYPE "M" THREADED COUPLING CHECKED BY: ZC SCALE: 2.6TopLoad.idw 1/2 SIZE: A JOB NO: DRAWING NO.: SHEET 6 OF 35 SPRINKLER HOSE SPRINKLER PORT SPRINKLER HEAD (INSTALLED BY OTHERS) SECTION C-C SCALE 1 / 2 THIS DRAWING IS THE PROPERTY OF HUNTAIR CLEANPAK AND CAN NOT BE REPRODUCED IN WHOLE OR IN PART, NOR DELIVERED TO OTHERS WITHOUT THE EXPRESS WRITTEN PERMISSION OF HUNTAIR CLEANPAK. FILE NAME: DRAWN BY: Jon H ISSUED ON: 08/08/13 CLEANPAK a CES Group Brand TITLE: 19855 SW 124th AVE. TUALATIN, OR 97062 Phone (503) 639-0113 www.huntair.com 2.6 TOP LOAD GRID SPRINKLER FLEXIBLE HOSE CHECKED BY: ZC SCALE: 2.6TopLoad.idw 1/2 SIZE: A JOB NO: DRAWING NO.: SHEET 7 OF 35 PORT SECTION D-D SCALE 1 / 2 THIS DRAWING IS THE PROPERTY OF HUNTAIR CLEANPAK AND CAN NOT BE REPRODUCED IN WHOLE OR IN PART, NOR DELIVERED TO OTHERS WITHOUT THE EXPRESS WRITTEN PERMISSION OF HUNTAIR CLEANPAK. FILE NAME: DRAWN BY: Jon H ISSUED ON: 08/08/13 CLEANPAK a CES Group Brand TITLE: 19855 SW 124th AVE. TUALATIN, OR 97062 Phone (503) 639-0113 www.huntair.com 2.6 TOP LOAD GRID PORT CHECKED BY: ZC SCALE: 2.6TopLoad.idw 1/2 SIZE: A JOB NO: DRAWING NO.: SHEET 8 OF 35 NOMINAL GRID CENTERLINES - 1.625" 4.296 6.921 SECTION E-E SCALE 1 / 4 THIS DRAWING IS THE PROPERTY OF HUNTAIR CLEANPAK AND CAN NOT BE REPRODUCED IN WHOLE OR IN PART, NOR DELIVERED TO OTHERS WITHOUT THE EXPRESS WRITTEN PERMISSION OF HUNTAIR CLEANPAK. FILE NAME: DRAWN BY: Jon H ISSUED ON: 08/08/13 CLEANPAK a CES Group Brand TITLE: 19855 SW 124th AVE. TUALATIN, OR 97062 Phone (503) 639-0113 www.huntair.com 2.6 TOP LOAD GEL GRID FILTER TOP LOAD PLEMUN STYLE CHECKED BY: ZC SCALE: 2.6TopLoad.idw 1/4 SIZE: A JOB NO: DRAWING NO.: SHEET 9 OF 35 NOMINAL GRID CENTERLINES - 1.625" 8.679 11.304 SECTION F-F SCALE 1 / 4 THIS DRAWING IS THE PROPERTY OF HUNTAIR CLEANPAK AND CAN NOT BE REPRODUCED IN WHOLE OR IN PART, NOR DELIVERED TO OTHERS WITHOUT THE EXPRESS WRITTEN PERMISSION OF HUNTAIR CLEANPAK. FILE NAME: DRAWN BY: Jon H ISSUED ON: 08/08/13 CLEANPAK a CES Group Brand TITLE: 19855 SW 124th AVE. TUALATIN, OR 97062 Phone (503) 639-0113 www.huntair.com 2.6 TOP LOAD GEL GRID FILTER TOP LOAD TERMINAL DUCTED FILTER STYLE CHECKED BY: SCALE: 2.6TopLoad.idw 1/4 SIZE: A JOB NO: DRAWING NO.: SHEET 10 OF 35 NOMINAL GRID CENTERLINES - 1.625" SECTION G-G SCALE 1/4 THIS DRAWING IS THE PROPERTY OF HUNTAIR CLEANPAK AND CAN NOT BE REPRODUCED IN WHOLE OR IN PART, NOR DELIVERED TO OTHERS WITHOUT THE EXPRESS WRITTEN PERMISSION OF HUNTAIR CLEANPAK. FILE NAME: DRAWN BY: Jon H ISSUED ON: 08/08/13 CLEANPAK a CES Group Brand TITLE: 19855 SW 124th AVE. TUALATIN, OR 97062 Phone (503) 639-0113 www.huntair.com 2.6 TOP LOAD GEL GRID TOP LOAD BLANK PAN GEL CHECKED BY: SCALE: 2.6TopLoad.idw 1/4 SIZE: A JOB NO: DRAWING NO.: SHEET 11 OF 35 EQUALIZER SIZED AT NOMINAL GRID CENTERLINES - 1.625" SECTION H-H SCALE 1/4 THIS DRAWING IS THE PROPERTY OF HUNTAIR CLEANPAK AND CAN NOT BE REPRODUCED IN WHOLE OR IN PART, NOR DELIVERED TO OTHERS WITHOUT THE EXPRESS WRITTEN PERMISSION OF HUNTAIR CLEANPAK. FILE NAME: DRAWN BY: Jon H ISSUED ON: 08/08/13 CLEANPAK a CES Group Brand TITLE: 19855 SW 124th AVE. TUALATIN, OR 97062 Phone (503) 639-0113 www.huntair.com 2.6 TOP LOAG GEL GRID EQUALIZER ON TOP LOAD PLENUM FILTER CHECKED BY: SCALE: 2.6TopLoad.idw 1/4 SIZE: A JOB NO: DRAWING NO.: SHEET 12 OF 35 FFU SIZED AT NOMINAL GRID CENTERLINES - 1.500" 10.250 17.171 16.230 13.921 6.921 FILTER SIZED AT NOMINAL GRID CENTERLINES - 1.625" SECTION J-J SCALE 1/4 THIS DRAWING IS THE PROPERTY OF HUNTAIR CLEANPAK AND CAN NOT BE REPRODUCED IN WHOLE OR IN PART, NOR DELIVERED TO OTHERS WITHOUT THE EXPRESS WRITTEN PERMISSION OF HUNTAIR CLEANPAK. FILE NAME: DRAWN BY: Jon H ISSUED ON: 18/18/13 CLEANPAK a CES Group Brand TITLE: 19855 SW 124th AVE. TUALATIN, OR 97062 Phone (503) 639-0113 www.huntair.com 2.6 TOP LOAD GEL GRID FFU ON TOP LOAD PLENUM STYLE FILTER CHECKED BY: SCALE: 2.6TopLoad.idw 1/4 SIZE: A JOB NO: DRAWING NO.: SHEET 13 OF 35 SECTION K-K SCALE 1 / 2 THIS DRAWING IS THE PROPERTY OF HUNTAIR CLEANPAK AND CAN NOT BE REPRODUCED IN WHOLE OR IN PART, NOR DELIVERED TO OTHERS WITHOUT THE EXPRESS WRITTEN PERMISSION OF HUNTAIR CLEANPAK. FILE NAME: DRAWN BY: Jon H ISSUED ON: 08/08/13 CLEANPAK a CES Group Brand TITLE: 19855 SW 124th AVE. TUALATIN, OR 97062 Phone (503) 639-0113 www.huntair.com 2.6 TOP LOAD GRID FLUSH LIGHT T5 CHECKED BY: SCALE: 2.6TopLoad.idw 1/2 SIZE: A JOB NO: DRAWING NO.: SHEET 14 OF 35 SECTION L-L SCALE 1 / 2 THIS DRAWING IS THE PROPERTY OF HUNTAIR CLEANPAK AND CAN NOT BE REPRODUCED IN WHOLE OR IN PART, NOR DELIVERED TO OTHERS WITHOUT THE EXPRESS WRITTEN PERMISSION OF HUNTAIR CLEANPAK. FILE NAME: DRAWN BY: Jon H ISSUED ON: 08/09/13 CLEANPAK a CES Group Brand TITLE: 19855 SW 124th AVE. TUALATIN, OR 97062 Phone (503) 639-0113 www.huntair.com 2.6 TOP LOAD GRID FLUSH LIGHT T8 CHECKED BY: SCALE: 2.6TopLoad.idw 1/2 SIZE: A JOB NO: DRAWING NO.: SHEET 15 OF 35 EXTERIOR GRID PROFILE BOLT HOLES ARE TYPICALLY SPACED 6.0" FROM EACH END OF PLENUM AND 24.0" O.C. 5/16" WASHER 5/16-18 WHIZ NUT 5/16-18 x 3/4" BOLT EXTERIOR PUNCHED FOR GEL SHARE GEL POURED IN FIELD 5.050 TYP. FIELD CAULKING 2.600 FIELD INSTALLED LIGHT FIXTURE (IF APPLICABLE) SECTION M-M SCALE 1 / 2 THIS DRAWING IS THE PROPERTY OF HUNTAIR CLEANPAK AND CAN NOT BE REPRODUCED IN WHOLE OR IN PART, NOR DELIVERED TO OTHERS WITHOUT THE EXPRESS WRITTEN PERMISSION OF HUNTAIR CLEANPAK. FILE NAME: DRAWN BY: Jon H ISSUED ON: 08/09/13 CHECKED BY: CLEANPAK a CES Group Brand 19855 SW 124th AVE. TUALATIN, OR 97062 Phone (503) 639-0113 www.huntair.com TITLE: 2.6 TOP LOAD GEL GRID GEL-LINK MODULE TO MODULE JOINT MODULE SEAM LIGHTING (IF APPLICABLE) SCALE: 2.6TopLoad.idw 1/2 SIZE: A JOB NO: DRAWING NO.: SHEET 16 OF 35 PERIMETER GRID PROFILE 5/16-18 WHIZ NUT 5/16" WASHER BOLT HOLES IN MODULES ARE TYPICALLY SPACED 6.0" FROM EACH END OF PLENUM AND 24" O.C. 5/16-18 x 0.75" BOLT 5.050 TYP. SECTION N-N SCALE 1 / 2 FIELD CAULKING FACE PLATE W/ GRID CLIP NOTES: FIELD CUTTING OF PERIMETER GRID INCLUDING CORNER MITERS ARE TO BE DONE IN THE FIELD. SOME BOLT HOLES IN PERIMETER GRID PIECES WILL NEED TO BE CUSTOM DRILLED IN THE FIELD. THIS DRAWING IS THE PROPERTY OF HUNTAIR CLEANPAK AND CAN NOT BE REPRODUCED IN WHOLE OR IN PART, NOR DELIVERED TO OTHERS WITHOUT THE EXPRESS WRITTEN PERMISSION OF HUNTAIR CLEANPAK. FILE NAME: DRAWN BY: Jon H ISSUED ON: 08/09/13 CLEANPAK a CES Group Brand TITLE: 19855 SW 124th AVE. TUALATIN, OR 97062 Phone (503) 639-0113 www.huntair.com 2.6 TOP LOAD GRID PERIMETER GRID CHECKED BY: SCALE: 2.6TopLoad.idw 1/2 SIZE: A JOB NO: DRAWING NO.: SHEET 17 OF 35 BOLT HOLES IN MODULES ARE TYPICALLY SPACED 6.0" FROM EACH END 24.0" O.C. PERIMETER GRID PROFILE 5/16-18 WHIZ NUT 5/16" WASHER 5/16-18 x 0.75" BOLT FIELD CAULKING FACE PLATE W/ GRID CLIP FIELD GASKET OR CAULKING BY OTHERS SECTION P-P SCALE 1 / 2 CLOSURE PLATE TRIMED TO WIDTH IN FIELD NOTES: FIELD CUTTING OF PERIMETER GRID INCLUDING CORNER MITERS ARE TO BE DONE IN THE FIELD. SOME BOLT HOLES IN PERIMETER GRID PIECES WILL NEED TO BE CUSTOM DRILLED IN THE FIELD. THIS DRAWING IS THE PROPERTY OF HUNTAIR CLEANPAK AND CAN NOT BE REPRODUCED IN WHOLE OR IN PART, NOR DELIVERED TO OTHERS WITHOUT THE EXPRESS WRITTEN PERMISSION OF HUNTAIR CLEANPAK. FILE NAME: DRAWN BY: Jon H ISSUED ON: 08/09/13 CLEANPAK a CES Group Brand TITLE: 19855 SW 124th AVE. TUALATIN, OR 97062 Phone (503) 639-0113 www.huntair.com 2.6 TOP LOAD GRID PERIMETER GRID WITH CLOSURE PLATE TO WALL CHECKED BY: SCALE: 2.6TopLoad.idw 1/2 SIZE: A JOB NO: DRAWING NO.: SHEET 18 OF 35 PREIMETER GRID PROFILE BOLT HOLES IN MODULES ARE TYPICALLY SPACED 6.0" FROM EACH END OF PLENUM AND 24.0" O.C. 5/16" WASHER 5/16-18 x .75" BOLT 5/16-18 WHIZ NUT ATTACHMENT TO WALL BY OTHERS FIELD CAULK BY OTHERS FIELD CAULKING FACE PLATE WITH GRID CLIP FIELD GASKET OR CAULKING BY OTHERS SECTION R-R SCALE 1 / 2 CLOSURE PLATE TRIMMED TO WIDTH IN FIELD NOTES: FIELD CUTTING OF PERIMETER GRID INCLUDING CORNER MITERS ARE TO BE DONE IN THE FIELD. SOME BOLT HOLES IN PERIMETER GRID PIECES WILL NEED TO BE CUSTOM DRILLED IN THE FIELD. THIS DRAWING IS THE PROPERTY OF HUNTAIR CLEANPAK AND CAN NOT BE REPRODUCED IN WHOLE OR IN PART, NOR DELIVERED TO OTHERS WITHOUT THE EXPRESS WRITTEN PERMISSION OF HUNTAIR CLEANPAK. FILE NAME: DRAWN BY: Jon H ISSUED ON: 08/12/13 CHECKED BY: SCALE: 2.6TopLoad.idw 1/2 CLEANPAK a CES Group Brand 19855 SW 124th AVE. TUALATIN, OR 97062 Phone (503) 639-0113 www.huntair.com TITLE: 2.6 TOP LOAD GRID PERIMETER GRID WITH CLOSURE PLATE AND GEL SEALED FUNCTIONAL WALL CLOSURE SIZE: A JOB NO: DRAWING NO.: SHEET 19 OF 35 PERIMETER GRID PROFILE 5/16" WASHER 5/16-18 WHIZ NUT 5/16-18 x 3/4" BOLT BOLT HOLES IN MODULES ARE TYPICALLY SPACED 6.0" FROM EACH END OF PLENUM AND 24.0" O.C. FIELD CAULKING SECTION T-T SCALE 1 / 2 1"x1" ANGLE WELDED TO SHIP LOOSE PERIMETER GRID NOTES: FIELD CUTTING OF PERIMETER GRID INCLUDING CORNER MITERS ARE TO BE DONE IN THE FIELD. SOME BOLT HOLES IN PERIMETER GRID PIECES WILL NEED TO BE CUSTOM DRILLED IN THE FIELD. THIS DRAWING IS THE PROPERTY OF HUNTAIR CLEANPAK AND CAN NOT BE REPRODUCED IN WHOLE OR IN PART, NOR DELIVERED TO OTHERS WITHOUT THE EXPRESS WRITTEN PERMISSION OF HUNTAIR CLEANPAK. FILE NAME: DRAWN BY: Jon H ISSUED ON: 08/12/13 CLEANPAK a CES Group Brand 19855 SW 124th AVE. TUALATIN, OR 97062 Phone (503) 639-0113 www.huntair.com TITLE: 2.6 TOP LOAD GRID PERIMETER GRID WITH ANGLE LEDGE CHECKED BY: SCALE: 2.6TopLoad.idw 1/2 SIZE: A JOB NO: DRAWING NO.: SHEET 20 OF 35 SHEET METAL Z PIECE BY OTHERS FIELD CAULKING WALL AND COVING BY OTHERS SECTION U-U SCALE 1 / 2 NOTES: FIELD CUTTING OF PERIMETER GRID INCLUDING CORNER MITERS ARE TO BE DONE IN THE FIELD. SOME BOLT HOLES IN PERIMETER GRID PIECES WILL NEED TO BE CUSTOM DRILLED IN THE FIELD. THIS DRAWING IS THE PROPERTY OF HUNTAIR CLEANPAK AND CAN NOT BE REPRODUCED IN WHOLE OR IN PART, NOR DELIVERED TO OTHERS WITHOUT THE EXPRESS WRITTEN PERMISSION OF HUNTAIR CLEANPAK. FILE NAME: DRAWN BY: Jon H ISSUED ON: 08/12/13 CLEANPAK a CES Group Brand TITLE: 19855 SW 124th AVE. TUALATIN, OR 97062 Phone (503) 639-0113 www.huntair.com 2.6 TOP LOAD GRID PERIMETER GRID INTERFACE TO WALL COVED CHECKED BY: SCALE: 2.6TopLoad.idw 1/2 SIZE: A JOB NO: DRAWING NO.: SHEET 21 OF 35 FIELD CAULKING HEAD TRACK BY OTHERS HEAD TRACK BY OTHERS WALL TO HEAD TRACK BY OTHERS WALL TO HEAD TRACK BY OTHERS AT PERIMETER GRID SECTION V-V SCALE 1 / 2 AT INTERIOR GRID SECTION W-W SCALE 1 / 2 THIS DRAWING IS THE PROPERTY OF HUNTAIR CLEANPAK AND CAN NOT BE REPRODUCED IN WHOLE OR IN PART, NOR DELIVERED TO OTHERS WITHOUT THE EXPRESS WRITTEN PERMISSION OF HUNTAIR CLEANPAK. FILE NAME: DRAWN BY: Jon H ISSUED ON: 08/12/13 CLEANPAK a CES Group Brand TITLE: 19855 SW 124th AVE. TUALATIN, OR 97062 Phone (503) 639-0113 www.huntair.com 2.6 TOP LOAD GRID WITH WALL INTERFACE CHECKED BY: SCALE: 2.6TopLoad.idw 1/2 SIZE: A JOB NO: DRAWING NO.: SHEET 22 OF 35 BLANK PAN SIZED AT NOMINAL GRID CENTERLINES - 1.250" SECTION Y-Y SCALE 5/16 THIS DRAWING IS THE PROPERTY OF HUNTAIR CLEANPAK AND CAN NOT BE REPRODUCED IN WHOLE OR IN PART, NOR DELIVERED TO OTHERS WITHOUT THE EXPRESS WRITTEN PERMISSION OF HUNTAIR CLEANPAK. FILE NAME: DRAWN BY: Jon H ISSUED ON: 08/15/13 CLEANPAK a CES Group Brand TITLE: 19855 SW 124th AVE. TUALATIN, OR 97062 Phone (503) 639-0113 www.huntair.com 2.6 TOP LOAD GASKETED GRID TOP LOAD BLANK PAN GASKET CHECKED BY: SCALE: 2.6TopLoad.idw 5/16 SIZE: A JOB NO: DRAWING NO.: SHEET 23 OF 35 SIZED AT NOMINAL GRID CENTERLINES - 1.40" SECTION AA-AA SCALE 5/16 THIS DRAWING IS THE PROPERTY OF HUNTAIR CLEANPAK AND CAN NOT BE REPRODUCED IN WHOLE OR IN PART, NOR DELIVERED TO OTHERS WITHOUT THE EXPRESS WRITTEN PERMISSION OF HUNTAIR CLEANPAK. FILE NAME: DRAWN BY: Jon H ISSUED ON: 08/15/13 CLEANPAK a CES Group Brand TITLE: 19855 SW 124th AVE. TUALATIN, OR 97062 Phone (503) 639-0113 www.huntair.com 2.6 TOP LOAD GASKETED GRID FILTER TOP LOAD TERMINAL DUCTED FILTER STYLE CHECKED BY: SCALE: 2.6TopLoad.idw 5/16 SIZE: A JOB NO: DRAWING NO.: SHEET 24 OF 35 FILTER SIZED AT NOMINAL GRID CENTERLINES - 1.400" FFU SIZED AT NOMINAL GRID CENTERLINES - 1.750" 16.421 13.171 SECTION AB-AB SCALE 5/16 THIS DRAWING IS THE PROPERTY OF HUNTAIR CLEANPAK AND CAN NOT BE REPRODUCED IN WHOLE OR IN PART, NOR DELIVERED TO OTHERS WITHOUT THE EXPRESS WRITTEN PERMISSION OF HUNTAIR CLEANPAK. FILE NAME: DRAWN BY: Jon H ISSUED ON: 08/15/13 CLEANPAK a CES Group Brand TITLE: 19855 SW 124th AVE. TUALATIN, OR 97062 Phone (503) 639-0113 www.huntair.com 2.6 TOP LOAD GASKETED GRID FFU ON TOP LOAD PLENUM STYLE FILTER WITH TOP FLANGE CHECKED BY: SCALE: 2.6TopLoad.idw 5/16 SIZE: A JOB NO: DRAWING NO.: SHEET 25 OF 35 SECTION AC-AC TYPE 3B HANGER GRID TO GRID LOAD CAPACITY: 3.75 Kips SECTION AD-AD TYPE 2B HANGER MIDSPAN LOAD CAPACITY: 3.75 Kips SECTION AE-AE TYPE 4X HANGER CORNER LOAD CAPACITY: 2.75 Kips THIS DRAWING IS THE PROPERTY OF HUNTAIR CLEANPAK AND CAN NOT BE REPRODUCED IN WHOLE OR IN PART, NOR DELIVERED TO OTHERS WITHOUT THE EXPRESS WRITTEN PERMISSION OF HUNTAIR CLEANPAK. FILE NAME: DRAWN BY: Jon H ISSUED ON: 08/19/13 CLEANPAK a CES Group Brand TITLE: 19855 SW 124th AVE. TUALATIN, OR 97062 Phone (503) 639-0113 www.huntair.com TYPICAL HANGERS 1/2" ATR CHECKED BY: SCALE: 2.6TopLoad.idw 1/4 SIZE: B JOB NO: DRAWING NO.: SHEET 26 OF 35 SECTION AF-AF TYPE 3C HANGER GRID TO GRID LOAD CAPACITY: 6.97 Kips SECTION AG-AG TYPE 3C HANGER MIDSPAN LOAD CAPACITY: 6.97 Kips SECTION AH-AH TYPE 4Z HANGER CORNER LOAD CAPACITY: 2.75 Kips THIS DRAWING IS THE PROPERTY OF HUNTAIR CLEANPAK AND CAN NOT BE REPRODUCED IN WHOLE OR IN PART, NOR DELIVERED TO OTHERS WITHOUT THE EXPRESS WRITTEN PERMISSION OF HUNTAIR CLEANPAK. FILE NAME: DRAWN BY: Jon H ISSUED ON: 08/19/13 CLEANPAK a CES Group Brand TITLE: 19855 SW 124th AVE. TUALATIN, OR 97062 Phone (503) 639-0113 www.huntair.com TYPICAL HANGERS 5/8" ATR CHECKED BY: SCALE: 2.6TopLoad.idw 1/4 SIZE: B JOB NO: DRAWING NO.: SHEET 27 OF 35 5/16-18 WHIZ NUT PERIMETER GRID PROFILE 5/16" WASHER 5/16-18 x 0.75" BOLT 5.050 BOLT HOLES IN MODULES ARE TYPICALLY SPACED 6.0" FROM EACH END OF PLENUM AND 24" O.C. FACE PLATE w/ GRID CLIP FIELD CAULKING SECTION AJ-AJ SCALE 1 / 4 NOTE: FIELD CUTTING OF PERIMETER GRID INCLUDING CORNER MITERS ARE TO BE DONE IN THE FIELD. BOLT HOLES IN PERIMETER GRID PIECES WILL NEED TO BE CUSTOM DRILLED IN THE FIELD. THIS DRAWING IS THE PROPERTY OF HUNTAIR CLEANPAK AND CAN NOT BE REPRODUCED IN WHOLE OR IN PART, NOR DELIVERED TO OTHERS WITHOUT THE EXPRESS WRITTEN PERMISSION OF HUNTAIR CLEANPAK. FILE NAME: DRAWN BY: Jon H ISSUED ON: 08/19/13 CLEANPAK a CES Group Brand TITLE: 19855 SW 124th AVE. TUALATIN, OR 97062 Phone (503) 639-0113 www.huntair.com 2.6 TOP LOAD PLENUM PERIMETER GRID CHECKED BY: SCALE: 2.6TopLoad.idw 1/4 SIZE: A JOB NO: DRAWING NO.: SHEET 28 OF 35 BOLT HOLES IN MODULES ARE TYPICALLY SPACED 6.0" FROM EACH END OF PLENUM AND 24" O.C. PERIMETER GRID PROFILE 5/16" WASHER 5/16-18 WHIZ NUT 5/16-18 x 3/4" BOLT 1"x1" ANGLE WELDED TO SHIP LOOSE PERIMETER GRID FIELD CAULKING SECTION AK-AK SCALE 1 / 4 NOTE: FIELD CUTTING OF PERIMETER GRID INCLUDING CORNER MITERS ARE TO BE DONE IN THE FIELD. BOLT HOLES IN PERIMETER GRID PIECES WILL NEED TO BE CUSTOM DRILLED IN THE FIELD. THIS DRAWING IS THE PROPERTY OF HUNTAIR CLEANPAK AND CAN NOT BE REPRODUCED IN WHOLE OR IN PART, NOR DELIVERED TO OTHERS WITHOUT THE EXPRESS WRITTEN PERMISSION OF HUNTAIR CLEANPAK. FILE NAME: DRAWN BY: Jon H ISSUED ON: 08/19/13 CLEANPAK a CES Group Brand FACE PLATE w/ GRID CLIP 19855 SW 124th AVE. TUALATIN, OR 97062 Phone (503) 639-0113 www.huntair.com TITLE: 2.6 TOP LOAD PLENUM PERIMETER GRID WITH ANGLE LEDGE CHECKED BY: SCALE: 2.6TopLoad.idw 1/4 SIZE: A JOB NO: DRAWING NO.: SHEET 29 OF 35 PERIMETER GRID PROFILE BOLT HOLES IN MODULES ARE TYPICALLY SPACED 6.0" FROM EACH END OF PLENUM AND 24.0" O.C. 5/16" WASHER 5/16-18 x .75" BOLT 5/16-18 WHIZ NUT FIELD CAULKING FACE PLATE w/ GRID CLIP CLOSURE PLATE TRIMMED TO WIDTH IN FIELD NOTE: FIELD CUTTING OF PERIMETER GRID INCLUDING CORNER MITERS ARE TO BE DONE IN THE FIELD. BOLT HOLES IN PERIMETER GRID PIECES WILL NEED TO BE CUSTOM DRILLED IN THE FIELD. THIS DRAWING IS THE PROPERTY OF HUNTAIR CLEANPAK AND CAN NOT BE REPRODUCED IN WHOLE OR IN PART, NOR DELIVERED TO OTHERS WITHOUT THE EXPRESS WRITTEN PERMISSION OF HUNTAIR CLEANPAK. FILE NAME: DRAWN BY: Jon H ISSUED ON: 08/20/13 SECTION AL-AL SCALE 1 / 4 CLEANPAK a CES Group Brand TITLE: FIELD GASKET OR CAULKING BY OTHERS 19855 SW 124th AVE. TUALATIN, OR 97062 Phone (503) 639-0113 www.huntair.com 2.6 TOP LOAD PLENUM PERIMETER GRID WITH CLOSURE PLATE TO WALL CHECKED BY: SCALE: 2.6TopLoad.idw 1/4 SIZE: A JOB NO: DRAWING NO.: SHEET 30 OF 35 BOLT HOLES IN MODULES ARE TYPICALLY SPACED 6.0" FROM EACH END OF PLENUM AND 24.0" O.C. PERIMETER GRID PROFILE 5/16" WASHER 5/16-18 x .75" BOLT 5/16-18 WHIZ NUT GEL POURED IN FIELD ATTACHMENT TO WALL BY OTHERS FIELD CAULK BY OTHERS EXTERIOR PUNCHED FOR GEL SHARE FIELD CAULKING FACE PLATE WITH GRID CLIP FIELD GASKET OR CAULKING BY OTHERS SECTION AM-AM SCALE 1 / 4 NOTE: FIELD CUTTING OF PERIMETER GRID INCLUDING CORNER MITERS ARE TO BE DONE IN THE FIELD. BOLT HOLES IN PERIMETER GRID PIECES WILL NEED TO BE CUSTOM DRILLED IN THE FIELD. THIS DRAWING IS THE PROPERTY OF HUNTAIR CLEANPAK AND CAN NOT BE REPRODUCED IN WHOLE OR IN PART, NOR DELIVERED TO OTHERS WITHOUT THE EXPRESS WRITTEN PERMISSION OF HUNTAIR CLEANPAK. FILE NAME: DRAWN BY: Jon H ISSUED ON: 08/20/13 CLEANPAK a CES Group Brand 2.6 TOP LOAD PLENUM PERIMETER GRID WITH CLOSURE PLATE TO WALL AND GEL SEALED FUNCTIONAL WALL CLOSURE SCALE: 2.6TopLoad.idw 19855 SW 124th AVE. TUALATIN, OR 97062 Phone (503) 639-0113 www.huntair.com TITLE: CHECKED BY: 1/4 CLOSURE PLATE TRIMMED TO WIDTH IN FIELD SIZE: A JOB NO: DRAWING NO.: SHEET 31 OF 35 PARIMETER GRID 5/16-18 WHIZ NUT 5/16" WASHER 5/16-18 x .75" BOLT SHEET METAL Z PIECE BY OTHERS FIELD CAULKING WALL AND COVING BY OTHERS NOTE: FIELD CUTTING OF PERIMETER GRID INCLUDING CORNER MITERS ARE TO BE DONE IN THE FIELD. BOLT HOLES IN PERIMETER GRID PIECES WILL NEED TO BE CUSTOM DRILLED IN THE FIELD. THIS DRAWING IS THE PROPERTY OF HUNTAIR CLEANPAK AND CAN NOT BE REPRODUCED IN WHOLE OR IN PART, NOR DELIVERED TO OTHERS WITHOUT THE EXPRESS WRITTEN PERMISSION OF HUNTAIR CLEANPAK. FILE NAME: DRAWN BY: Jon H ISSUED ON: 08/20/13 SECTION AN-AN SCALE 1 / 4 CLEANPAK a CES Group Brand TITLE: 19855 SW 124th AVE. TUALATIN, OR 97062 Phone (503) 639-0113 www.huntair.com 2.6 TOP LOAD PLENUM PERIMETER GRID INTERFACE TO WALL COVED CHECKED BY: SCALE: 2.6TopLoad.idw 1/4 SIZE: A JOB NO: DRAWING NO.: SHEET 32 OF 35 EXTERIOR GRID PROFILE 5/16" WASHER 5/16-18 WHIZ NUT 5/16-18 x .75" BOLT FIELD CAULKING SECTION AP-AP SCALE 1 / 4 THIS DRAWING IS THE PROPERTY OF HUNTAIR CLEANPAK AND CAN NOT BE REPRODUCED IN WHOLE OR IN PART, NOR DELIVERED TO OTHERS WITHOUT THE EXPRESS WRITTEN PERMISSION OF HUNTAIR CLEANPAK. FILE NAME: DRAWN BY: Jon H ISSUED ON: 08/20/13 CLEANPAK a CES Group Brand TITLE: SCALE: 2.6TopLoad.idw SIZE: 19855 SW 124th AVE. TUALATIN, OR 97062 Phone (503) 639-0113 www.huntair.com 2.6 TOP LOAD PLENUM MODULE TO MODULE JOINT MODULE SEAM LIGHTING WHERE APPLICABLE CHECKED BY: 1/4 FIELD INSTALLED LIGHT FIXTURE A JOB NO: DRAWING NO.: SHEET 33 OF 35 ATR BOLTED TO HOLE IN TOP OF PLENUM (HANGING ATR AND HARDWARE BY OTHERS) 1. BOLT TOGETHER LOOSELY WHEN SUSPENDING MODULES 5. TIGHTEN SUSPENSION HARDWARE 0 1 .5 Y P . T 1 TY .50 P. 4. BOLTS ALONG TOP OF PLENUM PLENUM 5/8" x 1-1/4 A325 BOLT, TYP. 5/8" F436 FLAT WASHER, TYP. 5/8" F436 FLAT WASHER, TYP. 3. BOLTS AT PLENUM CORNERS 5/8" A194 GR2H NUT, TYP. 5/16" WHIZ NUT 5/16" FLAT WASHER 5/16 x 3/4" GR5 BOLT 2. BOLTS AT PLENUM GRID CAULK SEAM CONTINUOUSLY AFTER ALL THE MODULES ARE BOLTED TOGETHER PRIOR TO INSTALLING FIELD-INSTALLED LIGHT FIXTURES SECTION AR-AR SCALE 3/16 NOTE: NUMBERS INDICATE SEQUENCE ORDER FOR MODULE INSTALLATION ASSEMBLY. THIS DRAWING IS THE PROPERTY OF HUNTAIR CLEANPAK AND CAN NOT BE REPRODUCED IN WHOLE OR IN PART, NOR DELIVERED TO OTHERS WITHOUT THE EXPRESS WRITTEN PERMISSION OF HUNTAIR CLEANPAK. FILE NAME: DRAWN BY: Jon H ISSUED ON: 08/20/13 CHECKED BY: CLEANPAK a CES Group Brand 19855 SW 124th AVE. TUALATIN, OR 97062 Phone (503) 639-0113 www.huntair.com TITLE: 2.6 TOP LOAD GRID BOLTING DETAIL WELDED PLENUM TO WELDED PLENUM SCALE: 2.6TopLoad.idw 3/16 SIZE: A JOB NO: DRAWING NO.: SHEET 34 OF 35 ROOF PANEL WELDED SPRINKLER COUPLER SPRINKLER HEAD INSTALLED IN FIELD BY OTHERS SECTION AT-AT SCALE 3/32 THIS DRAWING IS THE PROPERTY OF HUNTAIR CLEANPAK AND CAN NOT BE REPRODUCED IN WHOLE OR IN PART, NOR DELIVERED TO OTHERS WITHOUT THE EXPRESS WRITTEN PERMISSION OF HUNTAIR CLEANPAK. FILE NAME: DRAWN BY: Jon H ISSUED ON: 08/21/13 CLEANPAK a CES Group Brand TITLE: CHECKED BY: 19855 SW 124th AVE. TUALATIN, OR 97062 Phone (503) 639-0113 www.huntair.com 2.6 TOP LOAD GRID TYPICAL PLENUM SPRINKLER PIPING SCALE: 2.6TopLoad.idw 3/32 SIZE: A JOB NO: DRAWING NO.: SHEET 35 OF 35