ITEM No. 8. Digital Multimeter 06 No Specification: 1. Built-in LED flashlight to illuminate test area 2. Data logging capability (stores up to 10 readings) 3. Measurement capability of Voltage (AC, DC), Current (AC,DC), Frequency, Capacitance, Resistance, Temperature, Diode, continuity 4. IR-to-USB connectivity to transfer data to PC for record (Optional) IR port should be built in as standard. DETAIL SPECIFICATIONS: • • • • • • • • DC Voltage AC Voltage (True RMS) DC Current AC Current (True RMS) Resistance Capacitance Frequency Temperature ITEM No. 9. Function Generator : 600 mV – 600 V, Resolution – 0.1 mV : 600 mV – 600 V, Resolution – 0.1 mV : 60 µA – 10 A, Resolution – 0.01 µA : 60 µA – 10 A, Resolution – 0.01 µA : 600 Ω - 60 MΩ, Resolution – 0.1 Ω : 1000 nF – 10 mF, Resolution – 1 nF : 100 Hz – 100 KHz, Resolution – 0.01 Hz : - 40°C to +1000°C for K type, Resolution – 0.1°C 02 No Specification: 1) 2) 3) 4) 5) 6) 7) Capable of Generating Standard Waveforms like: Pulse, Sine, Square, Triangle, Ramp. Instrument should have option to upgrade as arbitrary waveform generator Should have capability of AM, FM, PM, FSK, PWM, BPSK, Sum (Carrier + Modulation) Linear & Logarithmic Sweep and Burst Mode of Operation. Compatible with through USB, GP IB and LAN. It should also be compatible with LXI Class C It should have graph mode for visual verification of Signal settings. It should have the required optional Software for control and generation of arbitrary waveform from PC. DETAILED TECHNICAL SPECIFICATION:-• • • • Frequency Frequency Resolution No of Channel Amplitude • • • • Amplitude Resolution Harmonic distortion in Sine wave Jitter (cycle-to-cycle, typ) Phase Noise Sweep • Burst • • • • • • • AM FM PM PWM FSK BPSK Power Supply : 1 µ Hz. to 20 MHz for Sine, Square, Pulse : 1 µ Hz. :1 : 1 mVpp - 10 Vpp in 50 ohms, 2 mVpp to 20 Vpp into open circuit. : 4 Digits : < 40 ps rms : - 125 dbc / Hz. At 100 KHz. Offset. : Linear, Logarithmic, List (up to 128 user-defined frequencies). : 1 to 1x108 cycles, or infinite. Start/stop phase -360° to 360°, 0.1° resolution : Source both Internal & External, Depth 0 to 120 %. : Source both Internal & External, Deviation 1µHz to 15 MHz. : Source both Internal & External, Deviation 0 to 360° : Source both Internal & External. Deviation 0 % to 100 %. : Source Internal timer, Rate 0 Hz – 1 MHz : Source Internal timer, Rate 0 Hz – 1 MHz : 230 v,50 Hz. ac. ITEM No. 10. A. DSO 01 No Specification: i) Upgradable in nature in terms of bandwidth , addition of Digital Logic channels to work on Mixed Signal mode ii) Manadatory Optional Built in Waveform Generator iii) High Update rate iv) Optional Segmented Memory mode to capture selectively and storing important segments of Signals only DETAILED TECHNICAL SPECIFICATIONS :1) No. of Channels 2) Bandwidth 3) Maximum Input 4) Timebase Range 5) Vertical Sensetivity 6) Trigger System 7) Sampling Rate 8) Memory Depth 9) Waveform update Rate 10) Segmented Memory (Optional) 11) Automatic Parameter Measurement 12) Built in waveform generator (Optional) 13) Display System 14) Built in interface ITEM No. 10. B. DSO : 2 : 70 MHz. (upgradable upto 200 MHz) : 400 V peak : 5 nsec. to 50 sec/div : 1mV/div – 5V/div : Edge, Pulse Width , Pattern , Duration , Video. : 2 GSa/s : 100 Kpts. Standard . : 50,000 waveforms / sec : To capture selected segments of the waveform . : Upto 23 parameters : Sine , Square , Pulse , Ramp etc. : 8.5 inch WVGA Colour : USB 2.0 high speed device, Optional LAN ,GP-IB and XGA output. 01 No Specification: 1) No. of Channels 2) Bandwidth 3) Maximum Input 4) Timebase Range 5) Vertical Sensetivity 6) Trigger System 7) Sampling Rate 8) Memory Depth 9) Waveform update Rate 10) Segmented Memory (Optional) 11) Automatic Parameter Measurement 12) Acquisition modes : 2 : 50 MHz. : 400 V peak : 5 nsec. to 50 sec/div : 2mV/div – 10V/div : Edge, Pulse Width , Force , Alternate , Video. : 1 GSa/s : 16 Kpts. Standard . : 200 waveforms / sec : To capture selected segments of the waveform. : Upto 23 parameters : Normal: Displays sampled data directly to the screen in real time. Averaging: Selectable from 2, 4,8,16, 32, 64, 128 or 256. Sequence: Selectable 1 to 1,000 acquisition. frames can be recorded, played back and stored in the scope memory or external USB memory. Peak detect: Captures high-frequency glitches as narrow as 20 nsec when viewing signals at slow sweep speeds. Roll:Waveform display rolls from right to left. minimum horizontal scale setting is 50 msec/div. 12) Built in interface ITEM No. 11. Power Supply : Built-in USB host and device ports and software to make documentation and PC connectivity easy. 03 No Specification: 1. 2. 3. 4. Built-in voltage and current measurement Full protection from over-voltage and over-current 85-265 Vac Universal AC input Fully compliant to LXI Class C specification Excellent load & line regulation Detail Technical Specification : • • • • • • No of Outputs Output Ratings Power Ripple & Noise Output Response Time Programming Accuracy (for ± 25 V) :3 : 0 to ± 25 V, 1 A; 0 to 6 V, 5 A : 750 W : CV – 100mVp-p, < 12 mVrms : 0.15 s : 0.05% + 20 mV 0.15% + 4 mA • Meter Resolution : Voltage – 10 mV Current – 10 mA • Maximum output float voltage : ± 240 Vdc