Transmittal Date: July 22, 2013 To: Steve Busen, LEED AP Skanska 26100 American Drive Suite 200 Southfield, Michigan 48034-2367 From: Shannon Shackelford Project: Cardiovascular Institute and Harper-Hutzel Specialty Center Detroit Medical Center, Detroit, Michigan Project No: 2011-10001-000 Owner Project No: Sent Via: Electronic – E-Builder Site Distribution: Jones Lange LaSalle Andrea Burg For your: Use/Records Jenkins Construction, Inc. James Robinson Enclosed Please Find: Quantity Description Product Data/Shop Drawings– APPROVED AS NOTED 1 Cubicles - Curtain Track Message: J/S Reference No. 823 Harley Ellis Devereaux Log No. 102123-1A Received by: Date: If checked, please return a signed copy to Harley Ellis Devereaux. If enclosures are not as noted, please inform us immediately. Transmittal.doc (Revised 01-08) \\DET-HAR-FILE01\STUDIO PROJECTS\HEALTHCARE\D M C HEALTH CARE CENTERS\2011-10001-000 CARDIO VAS INST\CONST\SHOPDRAW\SUBMITTAL LABELS AND TRANS\TRANSMITTA SUBMITTAL LABEL PROJECT NO: 2011-10001-000 DATE Cardiovascular Institute and Harper-Hutzel Specialty Center Detroit Medical Center Detroit, Michigan July 9, 2013 CONTRACTOR/SUPPLIER Jenkins/Skanska DESCRIPTION Product Data/Shop Drawing Cubicles - Curtain Track J/S Reference No. 0823 102123 PROJECT SPECIFICATION NO. COMMENTS GENERAL REVIEW NOTES 1. Coordinate work with related trades. 2. See individual sheets for additional review comments. 3. Lengths and quantities not verified, provided as generally indicated on the drawings and conditions constructed in the field. Kevin Doyle 7/18/13 X 2011-10001-000 102123-1A ! ! "#$#%&'( ('''&'" !)!!! *+! &$%( !, +* -1! &&&' '&%'%( & * ! 3 + - . /, 01. 2 ,, ! ! "#%%#%&'( !!! 4 * -1 *+! -1! * ! !"# #$ %% &'()%!( * +(),, -%% .+(),, - 65 ,! ! !1 ! % ! $!/ % ! $!3 *,5 *! +* ! ) ,, * ! 5 )-$ / !%% &'()%0 5,! % !,%%%% 8 ,% % !,%%%% 7#9 ,% *! !* !, !* 12314,151* 56 /77 12314,151*7 #9 56 /77 ,! ! !*- Jenkins Skanska Joint Venture Isiah White 7/8/13 DMC Cardiovascular Institute Harley Ellis Devereaux 0001-102123-0 102123 1 ! 0823 1! ! 8 +0:):% ! -1 89 C/S Cubicle Curtains Construction Specialties, Inc. 107 Johnson Blvd. Del Rio, TX 78840 Sales (908) 325-4900 Customer Service: (908) 849 4750 Customer Service Fax: (908) 849-4399 www.c/sgroup.com SHOP DRAWING TRANSMITTAL FOR APPROVAL ONLY - FABRICATION PENDING RELEASE Date: 07 /03 / 2013 PONTIAC CEILING & PARTITION 715 AUBURN RD PONTIAC, MI 48342 ATTN: JEFFREY M. STONE RE: DMC CARDIOVASCULAR INSTITUTE C/S ORDER NO: 998190 YOUR PO: SQ130006 Dear Customer, Thank you for purchasing C/S products. My name is Peter Lopez, with Construction Specialties Cubicle Curtains. Here at C/S we take great pride in our work. If you have any questions regarding these drawings, please contact me at (908) 849-4750 or at Email pelopez@c-sgroup.com. The enclosed shop drawings represent our interpretation of your order based on data in our possession and our standards. A field check is recommended. Our responsibility for job fit is limited to fabrication from these shop drawings when released by you as approved or corrected. A shipping schedule can be established only upon our receipt of one set of our shop drawings properly released and mutually acceptable. This release MUST INCLUDE YOUR COLOR SELECTION (IF APPLICABLE) AND A SIGNATURE. The average fabrication lead-time is two to three weeks on track orders and three to four weeks on curtains, depending on fabric availability. Best Regards, Peter Lopez. Drafting C/S Cubicle Curtains Company * Note: To help with faster lead times please include the following: 1. Ship to address. 2. Fabric and Color selected. 3. Date when material is required. ** Fabric will be ordered upon receipt of approved shop drawings. Re: SUBMITTALS Please find the following items enclosed: 1 SHOP DRAWING COPIE 2 TRACK SAMPLES WITH ACCESSORIES: SATIN ANODIZED Not included in this submittal. 2 IV TRACK SAMPLES: SATIN ANODIZED If you should have any questions please contact me. Thank you, Peter Lopez. C/S Cubicle Curtains. Phone: (908) 849-4750 Fax: (908) 849-4399 Email: pelopez@c-sgroup.com Construction Specialties, Inc. 107 Johnson Blvd. Del Rio, TX 78840 Sales (908) 325-4900 Customer Service: (908) 849-4750 Customer Service Fax: (908) 849-4399 Warranty Our Cubicle Track and IV Track are guaranteed against defects for one year after ship date provided it is installed correctly and according to our installation instructions. We shall not, under any circumstances be liable for direct or consequential damages resulting from the use of our product that has been installed in any other way than by our instructions. MANUFACTURERS MANUFACTURERS AND DISTRIBUTORS OF HOSPITAL CUBICLE TRACK, CARRIERS AND CUBICLE CURTAINS Construction Specialties, Inc. 107 Johnson Blvd. Del Rio, TX 78840 Sales (908) 325-4900 Customer Service: (908) 849-4750 Customer Service Fax: (908) 849-4399 Maintenance Because of the simplicity of the cubicle track system, there are no operating or maintenance manuals. The All-Nylon wheels and axles are designed to perform flawlessly. No lubrication is necessary and short of an occasional dusting, there is nothing else required to be done. MANUFACTURERS AND DISTRIBUTORS OF HOSPITAL CUBICLE TRACK, CARRIERS AND CUBICLE CURTAINS SURFACE MOUNTED CUBICLE CURTAIN TRACK The C/S Cubicle Curtain track is Dual Channel, extruded aluminum track made from aluminum alloy in a anodized or white baked enamel. Track dimensions are 1 3/8" x 3/4" deep (see below) with a minimum wall. SMCCT #6062 * Drawing not to scale 1062N CARRIER Carrier Stop #162 Carrier Gate #262 Construction Specialties, Inc. 107 Johnson Blvd. Del Rio, TX 78840 Sales (908) 325-4900 Customer Service: (908) 849-4750 Customer Service Fax: (908) 849-4399 Splice #862 Specification for Surface Mounted Cubicle Track PART 2 – PRODUCTS 2.01 ACCEPTABLE MANUFACTURERS A. General: Cubicle Track system shall be complete as specified in this section and manufactured by Cubicle Curtains, Cranford, NJ. B. Substitutions: Other manufacturers are acceptable for evaluation only after compliance with Section 01630. 2.02 CUBICLE TRACK SYSTEM A. Cubicle Track: Surface-mounted tracks of heavy extruded aluminum alloy 6063 –T5, 1-3/8" x 3/4", slotted to receive roller carriers, compete with accessories and components required for complete and secure installations including splices, end caps and corner bends. 1. 2. Corner Bends: Shall have a 12" radius minimum. Finish: Satin Anodized. B. Carriers: Virgin nylon axle with nylon wheels, complete with nickel-plated brass bead-chain and hook assembly. C/S G E N E R A L C U B I C L E Construction Specialties, Inc. 107 Johnson Blvd. Del Rio, TX 78840 Sales (908) 325-4 4900 Customer Service: (908) 849 4750 Customer Service Fax: (908) 849-4 4399 INSTALLATION INSTRUCTIONS FOR CEILING-MOUNTED CUBICLE TRACK Attached is a copy of our Tally Sheet, which lists all items required for individual rooms. The totals shown on this list should be used to check items received in shipment. Reports of shortages will not be accepted if made after (5) days after shipment has been received. Large Bends (8'x8') will be furnished only where a project is large enough to offset the cost of crafting these bends. Where this is not permissible, Small Bends (2'x2') will be furnished with Splices and proper lengths of track - to be joined to the Small Bends. Measurements of Large Bends is approximately 8' 2 ½" x 8' 2 ½". These will be shipped this way, to be cut on the job. For proper installation, follow "Shop Drawing" for lay-out, if parts shipped were based on this. 1. Mark ceiling lightly where track is to be installed. Drill track at proper intervals. Start at the center point of radius, and drill every 3' 0" on both directions. NOTE: Drill must be in perfect center of track! When drilling ends of track, affix stops and gates and drill through these. 2. Prop track against ceiling with boards. Mark ceiling through drilled holes. Remove track and drill through ceiling. (Size of drill to be determined by type of fasteners you are using.) NOTE: If track is to be mounted against wood backings, then keep tracking against ceiling, drill "guide hole" through ceiling, and then use proper length of Wood Screws for a strong hold. 3. Head of fasteners should be pan-head - not to exceed Size No. 8 4. Carrier Stop used at Terminus of track, with Carrier Gate used at Curtain Stacking Point. Carriers need not be installed at this time; however, if they are, remove Gate From fitting and insert proper amount of Carriers required for the curtain to be used. Standard spacing is every 6" - which is more than ample to assure a strong installation. To figure proper amount of Carriers, use this guide: Size of Curtains - Double - Plus One. Example: 16' 0" Curtain - i.e. 16 plus 16 - plus one - total 33. 5. Where track has to be spliced, pay particular attention to ends being joined. The Splice being furnished has been designed in such a way to assure this; however, burrs cause the Carriers to bind. Clean ends thoroughly, file burrs off, even forma small chamfer as a safeguard, and slip both ends into Splice. Put fastener on both ends of track! Suspended Installation Basic instruction above also applies for a Suspended Installation, except the following: 1. Standard Suspension height from floor is 7' 3". Install Wall Sockets per dimensions on Shop Drawing at this height. Prop Large Bend, cut to proper size, with ends in Wall sockets. If an additional cubical is to be attached, fit "Radius Tie Assembly" at radius of first cubical. 2. Track Socket can be fitted to any of the four (4) points in the Radius Tie Assembly. With the track at proper length and attach to both sockets by self-tapping screws furnished. 3. Use additional risers if shown on Shop Drawing. 4. Carriers can be inserted into track by removing "Gate" which lies in Wall Sockets. Replace Gate after proper amount of Carriers has been inserted. 5. Ceiling Risers must be used wherever a Splicer is used. Specification for Surface Mounted IV Track PART 2 – PRODUCTS 2.01 ACCEPTABLE MANUFACTURERS A. General: IV Track system shall be complete as specified in this section and manufactured by Cubicle Curtains, Cranford, NJ. B. Substitutions: Other manufacturers are acceptable for evaluation only after compliance with Section 01630. 2.02 IV TRACK SYSTEM A. I.V. Tracks: Cubicle Curtains I.V. track model #17000. Surface-mounted tracks of heavy extruded aluminum alloy 6063-T5, 1 Ǫ" x ¾", slotted to receive twist lock I.V. Carrier, compete with accessories and components required for complete and secure installations including splicer’s, end caps and corner bends. 1. Finish: Satin Anodized. B. Carriers: Cubicle Curtains 17500 Twist-Lock I.V. Carrier, Carrier mechanism shall be designed to lock against surface of reinforcing I.V. Track. 1. Provide one carrier per unit of I.V. Track, or as needed. Surface Mounted I.V Tack The C/S General Cubicle I.V Track is dual channel, extruded aluminum track Made from aluminum alloy in baked white enamel. Aluminum I.V Carrier Stop # 162(W) 17500 TWIST LOCK I.V. CARRIER Aluminum I.V Carrier Gate # 262(W) I.V Splice # 862(W) 17500 Twist Lock I.V. Carrier This I.V. carrier’s body and wheels are manufactured from one-piece molded Celcon. The shaft and safety hook are nickel chrome plated steel. The carrier locks by twisting the safety hook ¼ turn. 49 Meeker Avenue Cranford, NJ 07016 Tel: (908) 849-4749 Fax: (908) 849-4399 DELUXE 5 BOTTLE I.V. PENDANT MODEL# 17150 Fabricated of polished stainless steel this unit has a ¾" diameter tubing for the main shaft, 3/8" diameter for the inner shaft, and four folding ¼" diameter spiral safety arms plus one additional hook in the bottom as the fifth holder. 30” This proposal is most similar to the project specified surface mounted details for Cubicle Curtain and IV Track, for lay-in ceiling and gyp bd ceiling. See details 1 & 2 on Sht A5-51 and abide. Not applicable to project Confirm assigned scope. Only curtains are not construction scope responsibility. Yes P/R 1 ISO 41030A