AL9 - AL40 General information DC operated, UL

advertisement
1
AL9 - AL40
General information
DC operated, UL rated, 3 phase
e
lin
e
th rs
ss cto
o
r
ta
Ac con
Application
AL and AL...Z contactors are mainly used for controlling 3-phase motors and for
controlling power circuits corresponding to their operating characteristics up to
690 and even 1000 VAC. and 440 VDC.
Control circuit types
AL9 - AL40: DC coil with low power consumption of 3W to 3.5W
AL9Z - AL16Z: DC coil with low power consumption of 2.4W. Designed to be
directly controlled by PLC.
Location of surge suppressors.
Quick mounting on DIN rail: EN 50022 and
EN 50023 standards:
Clear marking of coil voltages and frequencies.
35 x 7.5mm for AL9 - AL40
35 x 15mm for AL9 - AL40
Location of side mounted accessories: on right
or left hand side.
Terminal marking according to IEC 60947-4-1,
EN 50005, EN 50012 and NEMA standards.
Location of function marker.
Holes for screw mounting (screws not supplied).
Distance between holes according to EN 50003.
Stops for attaching front mounted accessories.
Terminal screws:
Terminals delivered in open position with captive
screws (unused terminal screws must be
tightened).
AL9 - AL40
• Posidrive (+,-) No° 2 for all AL contactors
Screwdriver guidance for all terminals makes it
possible to use motorized screwdrivers.
All terminals provide protection against accidental
direct contact with live parts according to
VDE0106 - Part. 100.
All AL9 - AL40 contactor terminals as well as
contactor auxiliary contacts and coil terminals
ensure IP20 degree of protection according to
IEC 60947-1.
Catalog number explanation
AL9 - 30 - 10 - 81
Frame size
Coil voltage
(see coil voltage selection chart)
Power pole
Auxiliary contacts
30 = 3 NO
10 = 1 NO & 0 NC
01 = 0 NO & 1 NC
Coil voltage selection
Hz
Contr.
type
12
24
48
110
125
220
240
DC
AL
80
81
83
86
87
88
89
15
28
DC
Volts
AL...Z
For other voltages, see page 1.26.
1.6
1SXU000023C0202
Low Voltage Products & Systems
ABB Inc. • 888-385-1221 • www.abb-control.com
Ac
AL9 - AL40, AL9Z - AL16Z
Non-reversing, mechanically interlocked, reversing
DC operated, UL rated, 3 phase
AL9-30-10-81
AL26-30-10-81
ro
co ss
nt the
ac
to line 1
rs
AL40-30-10-81
AL Contactors — 3W and 3.5W consumption
General purpose
current
Maximum motor
Standard
Aux. contacts
horsepower ratings
UL motor switching 208V
240V
480V
575/600V
NO
NC
current AC1
Non-reversing
Catalog
number
Mechanically interlocked
List
price
Catalog
number
Reversing
List
price
Catalog
number
List
price
UL rated
AL9M-30-10-81
AL9R-30-10-81
$ 319
AL9M-30-01-81 AL9R-30-01-81
21
9
2
2
5
7.5
1
0
0
1
AL9-30-10-81
AL9-30-01-81
25
11
3
3
7.5
10
1
0
0
1
AL12-30-10-81
AL12-30-01-81
135
AL12M-30-10-81
AL12R-30-10-81
417
AL12M-30-01-81 AL12R-30-01-81
477
30
17
5
5
10
15
1
0
0
1
AL16-30-10-81
AL16-30-01-81
150
AL16M-30-10-81
AL16R-30-10-81
441
AL16M-30-01-81 AL16R-30-01-81
501
40
28
7.5
10
20
25
1
0
0
1
AL26-30-10-81
AL26-30-01-81
190
AL26M-30-10-81
AL26R-30-10-81
473
AL26M-30-01-81 AL26R-30-01-81
533
50
34
10
10
20
30
1
0
0
1
AL30-30-10-81
AL30-30-01-81
260
AL30M-30-10-81
AL30M-30-01-81
AL30R-30-10-81
618
AL30R-30-01-81
678
60
42
10
15
30
40
1
0
0
1
AL40-30-10-81
AL40-30-01-81
300
AL40M-30-10-81
AL40M-30-01-81
715
AL40R-30-10-81
AL40R-30-01-81
775
$ 110
$ 379
ALZ Contactors — 2.4W consumption
General purpose
current
Maximum motor
Standard
Aux. contacts
horsepower ratings
UL motor switching 208V
240V
480V
575/600V
NO
NC
current AC1
Non-reversing
Catalog
number
Mechanically interlocked
List
price
Catalog
number
List
price
Reversing
Catalog
number
List
price
UL rated
AL9ZM-30-10-15
AL9ZR-30-10-15
$ 319
AL9ZM-30-01-15 AL9ZR-30-01-15
135
AL12ZM-30-10-15
AL12ZR-30-10-15
417
AL12ZM-30-01-15 AL12ZR-30-01-15
477
AL16ZM-30-10-15
AL16ZR-30-10-15
441
AL16ZM-30-01-15 AL16ZR-30-01-15
501
21
9
2
2
5
7.5
1
0
0
1
AL9Z-30-10-15
AL9Z-30-01-15
25
11
3
3
7.5
10
1
0
0
1
AL12Z-30-10-15
AL12Z-30-01-15
30
17
5
5
10
15
1
0
0
1
AL16Z-30-10-15
AL16Z-30-01-15
150
$ 110
$ 379
Coil voltage selection
Mechanical interlock
All DC operated catalog numbers include a 24VDC coil. To select other coil
voltages, substitute the code from the Coil Voltage Selection Chart for the two
digits after the last dash in the catalog number.
Ex.: A 48V coil is required for an AL30 contactor: AL30-30-10-83
Mechanically interlocked contactors are designed for reversing, 2 speed, reduced
voltage, etc. type starter applications. The complete assembly consists of two
mechanically and electrically interlocked contactors mounted as follows with line
and load terminals:
Auxiliary contact blocks
• AL9 & AL16 — mounted on 35mm DIN rail
• AL26 & AL40 — mounted on common baseplate
For additional auxiliary contact blocks, see catalog number explanation on page
1.6. Add $ 20 to list price for each additional auxiliary, and see page 1.18 for
available combinations.
Hz
Contr.
type
12
24
48
110
125
220
240
DC
AL
80
81
83
86
87
88
89
15
28
DC
Volts
AL...Z
The NC electrical interlock is provided
Reversing
Coil voltage selection
Power wiring is not included.
Reversing contactors are designed for reversing type starter applications. The
complete assembly consists of two mechanically and electrically interlocked
contactors mounted with line and load terminals.
For other voltages, see page 1.26.
1 Only coil voltages available for AL9Z – AL16Z.
Low Voltage Products & Systems
ABB Inc. • 888-385-1221 • www.abb-control.com
Discount schedule AA — AL9 - AL40
1.7
1SXU000023C0202