e lin e h s s t ctor s o 1 cr nta A co Accessories for A/AE/AL/AF contactors Terminal lug kits (Set of 3) Wire range ATK185 For contactor 6 – 300 MCM 4 – 400 MCM (2) 4-500 MCM (2) 2/0 – 500 MCM (3) 2/0 – 500 MCM (4) 4/0 – 500 MCM (4) 1/0 – 750 MCM (6) 1/0 – 750 MCM A145 – A185 A210 – A300 A210 – A300 AF400 – AF580 AF580 – AF1250 AF1350 AF1350 – AF2050 AF1350 – AF2050 Contact kits ATK750/3 ZL75 Catalog number For contactors List price $ 45 68 110 150 225 235 335 560 ATK185 ATK300 ATK300/2 ATK580/2 ATK750/3 ATK1350/4 ATK1650/4 ATK1650/6 Catalog number List price 3 Pole A/AE/AF50 A/AE/AF63 A/AE/AF75 A/AE/AF95 A/AE/AF110 ZL50 ZL63 ZL75 ZL95 ZL110 $ 113 135 158 225 255 A/AF145 A/AF185 A/AF210 A/AF260 A/AF300 ZL145 ZL185 ZL210 ZL260 ZL300 300 420 525 855 1,020 AF400 AF460 AF580 AF750 AF1250 AF1350 AF1650 AF2050 ZL400 ZL460 ZL580 ZL750 ZL1250 ZL1350 ZL1650 ZL2050 1,716 2,434 3,795 3,960 5,280 4,255 4,890 6,290 4 Pole A/AE45 A/AE50 A/AE75 ZLT45 ZLT50 ZLT75 150 150 210 3 Pole UA50 UA75 UA95 UA110 ZLU50 ZLU75 ZLU95 ZLU110 150 215 306 347 Mechanical latches ZL145 For contactors Catalog number A9 - A75, AE45 - AE75, & AL9 - AL40 List price $ 84 WB75A-∆ ∆ - Coil voltage suffix. Refer to Coil Voltage Selection chart and substitute the desired coil voltage suffix for the ∆. Coil voltage selection chart – mechanical latches for A, AE & AL contactors 50 Hz (AC/DC) 60 Hz (AC) WB75A-04 24 42 48 110 24 – 28 42 – 48 48 – 55 110 – 127 Voltage code 01 02 03 04 50 Hz (DC) 60 Hz (AC) 220 – 230 230 – 240 380 – 415 415 – 440 Voltage code 06 05 07 08 220 – 255 230 – 277 380 – 440 440 – 480 Range: WB75A for contactors A9 – A75, AL9 – AL40, AE45 – AE75 and control relays N and NL. Description: WB75A block: contains a mechanical latching device with electromagnetic impulse unlatching (AC or DC) or manual unlatching. Captive screw type connecting terminals, built-in cable clamps, M 3.5 (=, -) posidrive 1 screw with screwdriver guidance, delivered untightened and protected against accidental direct contact. Operation: After closing, the contactor continues to be held in the closed position by the latching mechanism should the supply voltage fail at the contact coil terminals. Contactor opening can be controlled: • Electrically by an impulse* (AC or DC) on the WB75A block coil. The coil is not designed to permanently energized. • Manually by pressing the pushbutton on the front face of the WB75A block. Mounting: WB75A is clipped onto the front face of the contactor. Identification markers BA5-50 1.20 1SXU000023C0202 Mounting on Coil voltage A/AE/AL/AF9 – A/AE/AL/AF110 Discount schedule ABA [OF] Pack of 50 Catalog number List price BA5-50 $ 15 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage