TPE Data cable Chainflex® CF12 CF12 TPE 10 x d Especially bendingresistant fine-wire stranded conductor Pressure extrudet element jacket ● for maximum load requirements ● TPE outer jacket ● double-shielded ● oil-resistant ● bio-oil-resistant ● PVC-free/halogen-free [°C] Temperature range R [°C] -35 °C to +100 °C, bending radius 10 x d Temperature range R Highly flexible braided copper shield moved [V] fixed -40 °C to +100 °C, bending radius 5 x d V max. R unsupported/gliding 10 m/s, 6 m/s a max. 100 m/s2 UV-resistant High Nominal voltage 300/300 V (according to DIN VDE 0245). Testing voltage 1500 V Oil Oil-resistant (according to EN 60811-2-1), bio-oil-resistant [a] R Center element for high tensile stresses UV V 2 conductors each stranded in especially short pitch (according to VDMA 24568). oil Silicon-free Gusset-filled, pressure extruded (in compliance with PV 3.10.7 – status 1992). Hal Highly flexible steel wire braid Free from silicon which can affect paint adhesion Halogen-free According to EN 50267-2-1. Conductor Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (according to EN 60228). Pressure extruded, halogen-free TPE blend Core insulation Mechanically high-quality TPE mixture. Core stranding 2 cores each stranded in pairs with short pitch lengths, core pairs also stranded with short pitch lengths. Core identification Cores < 0,5 mm2: color code in accordance with DIN 47100 Cores * 0,5 mm2: cores black with white numerals Element shield Extremely bending-resistant, tinned braided copper shield. Premium Line Coverage approx. 70% linear, approx. 90% optical. Element jacket TPE mixture adapted to suit the requirements in Energy Chains® over pair shield. Inner jacket TPE mixture adapted to suit the requirements in Energy Chains®. Overall shield Highly flexible shield consisting of galvanized steel wire braid. Coverage approx. 70% linear, approx. 90% optical. RoHS ... no minimum order quantity 88 Price index CF12 TPE 10 x d Outer jacket Low-adhesion mixture on the basis of TPE, especially abrasion-resistant and highly flexible, adapted to suit the requirements in Energy Chains®. RoHS VDE The cables are manufactured on the basis of VDE. CE According to 73/23/EWG, 93/68/EWG Lead free According to EU guideline (RoHS) 2002/95/EC. Chainflex® Colour: dark-blue (similar to RAL 5011) for maximum load requirements almost unlimited resistance to oil, also with bio-oils indoor and outdoor applications, UV-resistant especially for freely suspended and gliding travel distances up to 400 m storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, outdoor cranes, low-temperature applications, for especially high EMC safety Delivery program Number of cores and External Copper Weight Part No. conductor nominal diameter index [kg/km] cross section [mm ] approx. [mm] [kg/km] 12,0 74 2 CF12.02.04.02 (4 x (2 x 0,25)C)C 135 CF12.02.05.02 (5 x (2 x 0,25)C)C 12,0 93 220 CF12.05.03.02 (3 x (2 x 0,5) C)C 13,0 66 210 CF12.05.04.02 (4 x (2 x 0,5) C)C 14,0 88 255 CF12.05.05.02 (5 x (2 x 0,5) C)C 15,0 110 297 CF12.05.06.02 (6 x (2 x 0,5) C)C 17,0 132 360 CF12.05.08.02 (8 x (2 x 0,5) C)C 20,0 177 477 CF12.05.10.02 (10 x (2 x 0,5) C)C 22,0 221 548 CF12.05.14.02 (14 x (2 x 0,5) C)C 24,0 309 723 CF12.10.06.02 (6 x (2 x 1,0) C)C 20,0 198 542 Tel. +49-22 03-96 49-800 Fax +49-22 03-96 49-222 Typical application area Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with earthed conductor green-yellow x = without earthed conductor Test data Page 33 750 types from stock no cutting costs ... (for up to 10 cuts of the same type) 89