Assembly Sheet For #701401U
Non-IC Remodel Recessed Housing
R
SLV Lighting North America
5731 Benjamin Center Drive
Tampa, Florida 33634
READ THIS MANUAL CAREFULLY AND KEEP IT ACCESSIBLE FOR FURTHER REFERENCE!
USE AS DIRECTED:
This fixture is intended for installation in accordance with the National Electrical Code and local code
specifications. Failure to adhere to these codes and instructions may result in serious injury and/or
death. These instructions do not intend to cover all details or variations in equipment, nor to provide for
every possible condition related to installation, operation, maintenance, or mounting situation.
Should specific problems occur that are not addressed by these instructions, contact your Sales
Representative or distributor for assistance.
Phone:813.349.1900
Fax:813.349.1907
Version: A
Release Date:
2013-07-24
SAFETY INFORMATION
RISK OF FIRE : Recessed portions of recessed housing, other than at points of support, shall be spaced at least ½ inch from
combustible material. Thermal insulation shall not be installed within 3 inches of recessed housing or junction box, and shall not be
installed above fixture as to entrap heat and prevent the free circulation of air.
Warning: TURN POWER OFF BEFORE INSTALLING OR PERFORMING ANY MAINTENANCE ON THIS FIXTURE. Failure to do so may
result in severe injury or death.
The 12V (Lowe Voltage) electrical connection between the transformer and the fixture housing is already established through the
joining of the male/female Molex plugs. NOTE : Do not change the size of the openings on the female Molex pins. Doing so will cause
the connection to arc and the fixture to fail.
1
Package Contents
Wood Joist
Joist Alignment Tab
A
Nail
Bar Hanger
Description
Part
A
Luminaire
Quantity
1
Electrical Specifications:
Transformer:
Input: 120V AC
Type: Magnetic
Output: 120V 50W MAX
A. To mount the recessed fixture to the ceiling structure,
extend the adjustable bar hangers and firmly mount to
the ceiling joist support members.
Note: When installing to a wood joist, the convenient
mounting spikes may be used to hold the hanger bars
temporarily in place. The installation must be completed
with proper fasteners (not provided).
Screw or nail the bar hangers securely to the wood joists.
B. T-Bar cutouts are provided in the bar hangers. (Refer to
the below illustration)
Dimming:
Use magnetic low voltage dimming control with magnetic
transformer.
Cutout
T-Bar
Bar Hanger
Page 1 of 3
R
SLV Lighting North America
Assembly Sheet For #701401U
Non-IC Remodel Recessed Housing
5”
3.5” Dia.
14”
7.5”
Page 2 of 3
Assembly Sheet For #701401U
Non-IC Remodel Recessed Housing
R
SLV Lighting North America
2
5
Tab
Housing
Transformer
and Plate
Knockout
Housing
Junction Box
A. Remove the transformer and plate from the junction box
by pressing up on the Junction Box Tab.
B. Pry up one knockout from the top of the junction box.
3
A. Position the housing so that the rim is flush with the
finished ceiling. The recessed housing is adjustable
vertically (held in place by [3] lock screws).
B. Refer to the trim installation instructions to complete the
lamp and trim installation.
Supply Wire
Ground Wire
Hole
Lock Screw
Common Supply Wire
Wire Nut
Your installation is now completed and ready to use.
Retain this sheet for future reference.
Ground Wire
from Fixture
Hot Supply Wire
White Wire
from Fixture
Black Wire
from Fixture
A. Use wire nuts to make all wire connections. (Wire nuts
are not included with luminaires.)
B. Connect the common supply wire to the white wire from
fixture.
C. Connect the hot supply wire to the black wire from
fixture.
D. Connect the ground wire from supply to the ground wire
from fixture.
E. Wrap each wire nuts until wires are tightly joined
together. Wrap each connection with approved electrical
tape.
4
MAINTAIN AND CARE:
- Exchange the light source always before it reaches its
lifespan, to avoid personal injuries, or damages of the
luminaire or other objects.
- Disconnect the product from the power supply before you
replace the light source. Let the light source cool down
before replacement.
- Use only light sources that are suitable for the product.
Suitable light sources are indicated on the wattage label.
Tab
Transformer
and Plate
Junction Box
A. Carefully tuck all wires inside of the junction box.
B. Place the transformer and plate back onto the junction
box and secure with the junction box tab.