A. Drawings and general provisions of the Contract, including

advertisement
SECTION 22'I''16 - DOMESTIC WATER P¡PING
PART 1 - GENERAL
1.1
A.
REI-ATED DOCUMENTS
Drawings and general provisions
of the Contract, including General and
Supplementary
Conditions and Division 01 Specification Sections, apply to this Section,
'1.2
A.
B.
1.3
A.
1.4
A.
B.
SUMMARY
Section lncludes:
Under-building-slab and aboveground domestic water pipes, tubes, and flttings inside
1.
2.
buildings,
Encasement for piping,
Related Requirements:
Section 221113 "Facility Water Distribution Piping" for water-service piping outside the
building from source to the point where water-service piping enters the building.
1.
ACTION SUBMITTALS
Product Data: For transition fittings and dielectric fittings.
INFORMATIONALSUBMITTALS
System purging and disinfecting activities report.
Field quality-control reports.
PART 2 - PRODUGTS
2,1
A.
B.
2.2
A.
B.
C.
PIPING MATERIALS
Comply with requirements in "Piping Schedule" Article for applications of pipe, tube, fitting
materlals, and joining methods for specific serv¡ces, service locations, and pipe sizes.
Potable-water piping and components shall comply with
components shall be marked with "NSF-pw."
NSFl4 and NSF61. Plastic piping
COPPER TUBE AND FITTINGS
Hard Copper Tube: ASTM B 88, Type L water tube, drawn temper.
Sofi Copper Tube: ASTM B 88, Type K water tube, annealed temper.
Gast-Copper, Solder-Joint Fittings: ASME 816.18, pressure fittings.
Caslno
Oklahoma
CNE Permanent Ramona
Ramona,
Structural and Underfloor Utilities Package
25 July
2011
221116-1
Domestic Water Piping
D.
E.
2.3
A.
B.
C.
2.4
A.
B.
Wrought-Copper, Solder-Joint Fitt¡ngs: ASME 816.22, wrought-copper pressure fittings.
Bronze Flanges: ASME 816.24, Class 150, with solder-joint ends.
PIPING JOINING MATERIALS
Solder Filler Metals: ASTM B 32, lead-free alloys.
FIux; ASTM B 813, waterflushable.
Brazing Filler Metals: AWS 45.8/45.8M, BCuP Series, copper-phosphorus alloys for generalduty brazing unless othenryise indicated.
TRANSITION FITTINGS
General Requirements:
Same size as pipes to be joined.
Pressure rating at least equal to pipes to be joined.
End connections compatible with pipes to be joined.
1.
2.
3.
Fitting-Type Transition Couplings: Manufactured píping coupling or speciñed piping system
fitting.
C.
Sleeve-Type Transition Coupling: AWWA C219.
'l
.
Basis-of-Design Product: Subject
to compliance with requirements, provide product
indicated on Drawings or comparable product by one of the following:
a.
b.
c.
d.
e.
f.
S.
CascadeWaterworksManufacturing.
Dresser, lnc.; Piping Specialties Products.
Ford Meter Box Company, lnc. (The).
JCM lndustries.
Romac lndustríes, lnc.
Smith-Blair, lnc.; a Sensus company.
Viking Johnson.
PART 3 - EXECUTION
3.1
A.
EARTHWORK
Comply with requirements
in Section 312000 "Earth Moving" for excavating, trenching,
and
backfilling.
3.2
A.
PIPING INSTALLATION
Drawing plans, schematics, and diagrams indicate general location and arrangement of
domestic water piping. lndicated locations and anangements are used to size pipe and
calculate friction loss, expansion, and other design considerations. lnstall piping as indicated
unless deviations to layout are approved on coordination drawings.
Casino
Oklahoma
CNE Permanent Ramona
Ramona,
Structural and Underfloor Utilities Package
25 July
2O11
221116-2
Domestic Water Piping
B.
C.
lnstall copper tubing under building slab according to CDAs "Copper Tube Handbook."
lnstall underground copper tube
in PE encasement according to ASTM A 674 or
AìM/VA C105/421.5.
D.
lnstall shutotf valve, hose-end drain valve, strainer, pressure gage, and test tee with valve
inside the building at each domestic water-service entrance.
E.
F.
G.
lnstall piping free of sags and bends.
lnstall fittings for changes in direction and branch connections.
lnstall sleeve seals for piping penetrations of concrete
slabs. Comply with requirements for
sfeeve seals specified in Section 220517 "Sleeves and Sleeve Seals for Plumbing Piping."
3.3
A.
B.
JOINT CONSTRUCTION
Ream ends of pipes and tubes and remove burrs.
Remove scale, slag, dirt, and debris from inside and outside of pipes, tubes, and fittings before
assembly.
C.
Brazed Joints for Copper
Joints" chapter.
D.
Soldered Joints for Copper Tubing: Apply ASTM B 813, water-flushable flux to end of tube.
Join copper tube and fittings according to ASTM B 828 or CDA's "Copper Tube Handbook."
E.
3.4
A.
Tubing: Comply with CDA's "Copper Tube Handbook,"
"Brazed
Extruded-Tee Connections: Not allowed.
IDENTIFICATION
ldentify system components. Comply with requirements for identification materials and
installation in Section 220553 "ldentification for Plumbing Piping and Equipment."
B.
3.5
A.
Label pressure piping with system operating pressure.
FIELD QUALITY CONTROL
Perform the following tests and inspections:
Piping lnspections:
1.
a.
b.
Do not enclose, cover, or put piping into operation until it has been inspected and
approved by authorities having jurisdiction.
During installation, notify authorities having jurisdiction at least one day before
inspection must be made. Perform tests specified below in presence of authorities
having jurisdiction:
Roughing-in lnspection: Anange for inspection of piping before concealing
or closing in after roughing in and before setting fixtures.
Final lnspection: Anange for authorities having jurisdiction 1o observe tests
specified in "Piping Tests" Subparagraph below and to ensure compliance
with requirements,
1)
2)
CNE Permanent Ramona Gaslno
Ramona, Oklahoma
Structural and Underfloor Utilities Package
25 July 2011
221116-3
Domestic Water Piping
c.
d.
2.
Reinspection: lf authorities having jurisdiction find that piping will not pass tests or
inspections, make required conections and arrange for reinspection.
Reports: Prepare inspection reports and have them signed by authorities having
jurisdiction.
Piping Tests:
Provide an airlwater pressure test on all underground piping prior to concrete pour.
Test for leaks and defects in new piping and parts of existing piping lhat have been
altered, extended, or repaired. lf testing is performed in segmenls, submit a
separate report for each test, complete with diagram of portion of piping tested.
Leave new, altered, extended, or replaced domestic water piping uncovered and
a.
b,
c.
unconcealed until
d.
e.
f.
3.6
it has
been tested and approved, Expose work that was
covered or concealed before it was tested.
Cap and subject piping to static airlwater pressure of 50 psig above operating
pressure, without exceeding pressure rating of piping system materials. lsolate
test source and allow it to stand for four hours. Leaks and loss in test pressure
constitute defects that must be repaired.
Repair leaks and defects with new materials, and retest piping or portion thereof
until satisfactory results are obtained.
Prepare reports for tests and for conective action required.
B.
Domestic water piping will be considered defective if it does not pass tests and inspections.
c.
Prepare test and inspection reports.
CLEANING
Clean and disinfect potable domestic water piping as follows:
1.
2.
Purge new piping and parts of existing piping that have been altered, extended, or
repaired before using.
Use purging and disinfecting procedures prescribed by authorities having jurisdiction; if
methods are not prescribed, use procedures described ín either AWWA C651 or
AWWA C652 or follow procedures described below:
Flush piping system with clean, potable water until dirty water does not appear at
outlets.
Fill and isolate system according to either of the following:
Fill system or part thereof with water/chlorine solution with at least 50 ppm
of chlorine. lsolate with valves and allow to stand for 24 hours.
Fill system or parl thereof with water/chlorine solution with at least 200 ppm
of chlorine. lsolate and allow to stand for three hours.
Flush system with clean, potable water until no chlorine is in water coming from
system after the standing time,
Repeat procedures if biological examination shows contamination.
Submit water samples in sterile bottles to authorities having jurisdiction.
a.
b.
1)
2)
c,
d.
e.
Clean non-potable domestic water piping as follows:
1.
2.
Purge new piping and parts of existing piping that have been altered, extended, or
repaired before using.
Use purging procedures prescribed by authorities having jurisdiction or: if methods are
not prescribed, follow procedures descríbed below:
Flush piping system with clean, potable water until dirly water does not appear at
outlets.
Submit water samples in sterile bottles to authorities having jurisdiction. Repeat
procedures if biological examination shows contamination.
a.
b.
CNE Permanent Ramona Casino
Ramona, Oklahoma
Structural and Underfloor Utilities Package
25 July 2011
2211164
Domestic Water Piping
c.
Prepare and submit reports of purging and disinfecting activities. lnclude copies of watersample approvals from authorities having jurisdiction.
D
3.7
A.
B.
C.
D.
Clean interior of domestic water piping system. Remove dirt and debris as work progresses.
PIPING SCHEDULE
Transition and special fittings with pressure ratings at least equal to piping rating may be used
in applications below unless otherwise indicated.
Flanges and unions may be used for aboveground piping joints unless otherwise indicated.
Fitting Option: Extruded-tee connections are not allowed.
Under-building-slab, domestic water, building-sèrvice piping, NPS 3 and smaller, shall be the
following:
1.
E.
Soft copper tube, ASTM B 88, Type K; wrought-copper, solder-joint fittings; and brazed
joints.
Under-building-slab, domestic water piping, NPS 2 and smaller, shall be the following:
Hard copper tube, ASTM B 88, Type L; wrought-copper, solder-joint fittings: and brazed
joints.
1,
END OF SECTION 221116
CNE Permanent Ramona Casino
Ramona, Oklahoma
Structural and Underfloor Utilities Package
25 July 2Q11
221116-5
Domestic Water Piping
SECTION 221316. SANITARY WASTE AND VENT PIPING
PART 1 - GENERAL
1.1
A.
RELATED DOCUMENTS
Drawings and general provisions
of the Contract,
including General and Supplementary
Conditions and Division 01 Specification Sections, apply to this Sec,tion.
1.2
A.
1.3
A.
SUMMARY
Section lncludes:
Pipe, tube, and fittings.
Specialty pipe fìttings.
Encasement for underground metal piping.
1.
2.
3.
PERFORMANCE REQUIREMENTS
Components and installation shall be capable of withstanding the following minimum working
pressure unless otherwise indicated:
I
Soil, Waste, and Vent Piping: 10-foot head of water.
Waste, Force-Main Piping: 50 psig.
.
2.
B.
1.4
A.
B.
,1.5
A.
B.
1.6
A.
Seismic Performance: SoÍ1, waste, and vent piping and support and installation shall withstand
the effects of earthquake motions determined according to ASCE/SEI 7.
ACTION SUBMITTALS
Product Data: For each type of product used.
Field quality-control reports.
QUALITY ASSURANCE
Piping materials shall bear label, stamp, or other markings of specified testing agency.
Comply with NSF/ANSI '14, "Plastics Piping Systems Components and Related Materials," for
plastic piping components, lnclude marking with "NSF-dwv'for plastic drain, waste, and vent
piping and "NSF-sewern for plastic sewer píping.
PROJECT CONDITIONS
lnterruption of Existing Sanitary Waste Service: Do not intenupt service to facilities occupied by
Owner or others unless permitted under the following conditions and then only after arranging to
provide temporary service according to requirements indicated:
Notifo Construction Manager no fewer than two days in advance of proposed interruption
of sanitary waste service.
1.
Casino
Oklahoma
GNE Permanent Ramona
Ramona,
Struc{ural and Underfloor Utilities Package
25 July 201
1
221316-1
Saintary Waste and Vent Piping
2.
Do not proceed with interruption of sanitary waste service without Architect's Construction
Manager's written permission.
PART 2 - PRODUCTS
2.1
A.
PIPING MATERIALS
Comply with requirements in "Piping Schedule" Arlicle for applications
of pipe, tube,
fitting
materials, and joining methods for specific services, service locations, and pipe slzes.
2,2
A.
B.
C.
2.3
A.
B.
C.
HUB-AND-SPIGOT, CAST-IRON SOIL PIPE AND FITTINGS
Pipe and Fittings: ASTM A 74, Service class(es).
Gaskets: ASTM C 564, rubber.
Calking Materials: ASTM B 29, pure lead and oakum or hemp fiber.
HUBLESS, CAST-IRON SOIL PIPE AND FITTINGS
Pipe and Fittings: ASTM A 888 or CISPI 301.
Sovent Stack Fittings: ASME 816.45 or ASSE 1043, hubless, cast-iron aerator and deaerator
drainage fittings.
ClSPl,Hubless-PipingGouplings:
Manufacturers: Subject to compliance with requirements, provide products by one of the
1.
following:
ANACO-Husky,
Dallas Specialty & Mfg. Co.
a.
b.
c.
d.
e.
f,
S.
h.
2.
3.
D.
Femco lnc.
Matco-Norca, lnc.
MIFAB, lnc.
Mission Rubber Company; a division of MCP lndustries, lnc.
Stant.
Tyler Pipe.
Standards: ASTM C 1277 and ClSPl310,
Description; Stainless-steel corrugated shield with stainless-sleel bands and tightening
devices; and ASTM C 564, rubber sleeve with integral, center pipe stop.
Heavy-Duty, Hubless-PipingCouplings;
Manufacturers: Subject to compliance with requirements, provide products by one of the
1.
foilowing:
a.
b.
c.
d.
e.
f.
S.
ANACO-Husky.
Clamp-AllCorp.
Dallas Specialty & Mfg, Co.
MIFAB,lnc.
Mission Rubber Company; a division of MCP lndustries, lnc.
Stant.
Tyter Pipe.
Gasino
Oklahoma
CNE Permanent Ramona
Ramona,
Structural and Underfloor Utilities Package
25 July
2011
221316-2
Saintary Waste and Vent Piping
2.
3.
E.
Standards: ASTM C 1277 and ASTM C 1540.
Description: Stainless-steel shield with stainless-steel bands and tightening devices; and
ASTM C 564, rubber sleeve with integral, center pipe stop.
Cast-lron,Hubless-PipingCouplings:
Manufacturers; Subject to compliance with requirements, provide products by one of the
1.
foltowing:
2.
3.
2.4
A.
B.
C.
GALVANIZED-STEEL PIPE AND FITTINGS
Galvanized-Steel Pipe: ASTM A 53/A 53M, Type E, Standard Weight
cut-grooved or threaded ends matching joining method.
E.
class. lnclude
square-
Cast-lron Drainage Fittings: ASME B16.12,threaded.
SteelPipe Pressure Fittings:
1. Steel Pipe Nipples: ASTM A 733, made of ASTM A 53/A 53M or ASTM A 106/A 106M,
Schedule 40, seamless steel pipe. lnclude ends matching joining method.
2. Malleable-lron Unions: ASME 816.39; Class 150; hexagonal-stock body with ball-and-
3.
D.
a.
MG Piping Products Company.
Standard: ASTM C 1277.
Description: Two-piece ASTM A 48/A 48M, cast-iron housing; stainless-steel bolts and
nuts; and ASTM C 564, rubber sleeve with integral, center pipe stop.
socket, metal-to-metal, bronze seating surface; and female threaded ends.
Gray-lron, Threaded Fittings: ASME 816.4, Class 125, standard pattem.
Cast-lron Flanges: ASME 816.1, Class 125.
Ftange Gasket Materials: ASME916.21, full-face, flat, nonmetallic, asbestos-free, 1/8inch maximum thickness unless thickness or specific material is indicated.
Flange Bolts and Nuts: ASME 818.2.1, carbon steel unless otherwise indicated,
'1.
2.
Grooved-Joint,Galvanized-Steel-PipeAppurtenances:
Manufacturers: Subject to compliance with requirements, provide products by one of the
1.
following:
a.
b.
c.
d.
2.
3.
2.5
A.
B.
Anvil lnternational; a subsidiary of Mueller Water Products, lnc.
Grinnell Mechanical Products
Shurjoint Piping Products.
Victaulic Company.
Galvanized, Grooved-End Fittings for Galvanized-Steel Piping: ASTM A 536 ductile-iron
castings, ASTM A 47lA47M malleable-iron castings, ASTM A 2341A234M forged steel
fittings, or ASTM A 106/A 106M steel pipes with dimensions matching ASTM A 53/A 53M
steel pipe, and complying with AWWA C606 for grooved ends.
Grooved Mechanical Gouplings for Galvanized-Steel Piping: ASTM F 1476, Type l.
lnclude fenous housing sections with continuous curved keys; EPDM-rubber gasket
suitable for hot and cold water; and bolts and nuts.
STAINLESS-STEEL PIPE AND FITTINGS
Pipe and Fittings: ASME A112.3.1, drainage pattern with socket and spigot ends.
lnternal Sealing Rings: Elastomeric gaskets shaped to fit socket groove.
CNE Permanent Ramona Casino
Ramona, Oklahoma
Structural and Underfloor Utilities Package
25 July 2011
221316-3
Saintary Waste and Vent Piping
26
DUCTITE-IRON PIPE AND FITTINGS
Ductile-lron, Mechanical-Joint Piping:
Ductile-lron Pipe: AWWA C1511A.21,51, with mechanical-joint bell and plain spigot end
unless grooved or flanged ends are indicated.
Ductile-lron Fittings: AWWA C110/421.10, mechanical-joint, ductile- or gray-iron
standard pattem or A\,VWA C153/421.53, ductile-iron compact pattem,
Glands, Gaskets, and Bolts: AWWA C1111Ê21.11, ductite- or gray-iron gtands, rubber
gaskets, and steel bolts.
1.
2.
3.
Ductile-lron, Push-on-Joint Piping:
Ductile{ron Pipe: AWWA C1511/.21.51, with push-on-joint bell and plain spigot end
unless grooved or flanged ends are indicated.
Ductile-lron Fiftings: AWWA C1101A21.1O, push-on-joint ductile- or gray-iron standard
patlern or A\¡VWA C 1 5 3/42 1 .53, d uctile-i ron compact pattern.
1.
2.
3.
c
Gaskets: AWWA C1111M1.'11, rubber.
Ductile-lron, Grooved-Joint Piping:
1.
2.
Ductile-lron
Pipe:
AWWAC151lM1.51 with round-cut-grooved ends according to
A\^rVVA C606.
Ductile-lron-Pipe Appurtenances:
Manufacturers: Subject to compliance with requirements, provide products by one
a.
of the followlng:
b.
1)
2)
3)
4)
Anvillntemational.
Shurjoint Piping Products.
Star Pipe Products,
Victaulic Company.
Grooved-End, Ductile-lron
dímensions matching
Fittings: ASTM A 536 ductile-iron castings with
AWWA C1101A21.10 ductite-iron pipe or
AWWAC153/421.53 ductile-iron fittings and complying with AWWAC606 for
c.
grooved ends.
Grooved Mechanical Couplings for Ductile-lron Pipe: ASTM F 1476, Type l.
lnclude ferrous housing sections with continuous curved keys; EPDM-rubber
center-leg gasket suitable for hot and cold water; and bolts and nuts.
27
COPPER TUBE AND FITTINGS
A.
B.
Copper D\¡/V Tube: ASTM B 306, drainage tube, drawn temper.
Copper Drainage Fittings: ASME 816.23, cast copper or ASME B1ô.29, wrought copper,
solder-joÌnt fittin gs.
c.
Hard Copper Tube: ASTM B 88, Type L and Type M, water tube, drawn temper.
D.
Soft Copper Tube: ASTM B 88, Type L, water tube, annealed temper,
E
Copper Pressure Fittings:
F.
1.
2.
Copper Fittings: ASME 816.18, cast-copper-alloy or ASME 816.22, wrought-copper,
solder-joi nt fittings. Furn ish wrou g ht-copper fittings if indicated.
Copper Unions: MSS SP-123, copper-alloy, hexagonal-stock body with ball-and-socket,
metal-to-metal seating surfaces, and solder-joint or threaded ends.
Copper Flanges: ASME 816.24, Class 150, cast copper with solder-joint end.
CNE Permanent Ramona Gasino
Ramona, Oklahoma
Structural and Underfloor Utilities Package
25 July 2011
2213164
Saintary Waste and Vent Piping
1.
2.
G
Flange Gasket Materials: ASME 816.21, full-face, flal, nonmetallic, asbestos-free, 1/8inch maximum thickness unless thickness or specific material is indicated,
Flange Bolts and Nuts: ASME 818.2.1, carbon steel unless otherwise indicated.
Solder: ASTM B 32, lead free with ASTM B 813, water-flushable flux.
ABS PIPE AND FITTINGS
2.8
A.
Solid-WallABS Pipe: ASTM D 2661, Schedule 40.
B.
Cellular-Core ABS Pipe: ASTM F 628, Schedule 40,
c.
ABS Socket Fittings: ASTM D 2661, made to ASTM D 3311, drain, waste, and vent patterns.
D.
Solvent Cement ASTM D 2235.
1.
2.
ABS solvent cement shall have a VOC content of 325 g/L or less when calculated
according to 40 CFR 59, Subpart D (EPA Method 24).
Solvent cement shall comply with the testing and product requirements of the Califomia
Department of Health Services' "Standard Practice for the Testing of Volatile Organic
Emissions from Various Sources Using Small-Scale Environmental Chambers."
PVC PIPE AND FITTINGS
2.9
A.
Solid-Wall PVC Pipe: ASTM D 2665, drain, waste, and vent.
B.
Cellular-Core PVC Pipe: ASTM F 891, Schedule 40.
c.
PVC Socket Fíttings: ASTMD2665, made to ASTM D3311, drain, waste, and vent patterns
and to fit Schedule 40 pipe,
Adhesive Primer: ASTM F 656.
Adhesive primer shall have a VOC conlent of 550 g/L or less when calculated according
to 40 CFR 59. Subpart D (EPA Method 24).
Adhesive primer shall comply wilh the testing and product requirements of the Califomia
Department of Health Services' "Stiandard Practice for the Testing of Volatile Organic
Emissions from Various Sources Using Small-Scale Environmental Chambers.'
1.
2.
2.10
A.
SPECIALTY PIPE FITTINGS
Transition Couplings:
General Requirements: Fitting or device for joining piping with small differences in OD's
or of different materials. lnclude end connections same size as and compatible with
pipes to be joined.
Fitting-Type TransitÍon Couplings: Manufactured piping coupling or specifled piping
2.
system fitting.
3.
Unshielded, Nonpressure Transition Couplings:
Manufacturers: Subject to compliance with requirements, provide products by one
1.
a.
b.
of the following:
Dallas Specialty & Mfg. Co.
Fernco lnc.
Misslon Rubber Company; a division of MCP lndustries, lnc.
Plastic Oddities; a division of Diverse Corporate Technologies, lnc.
Standard: ASTM C 1173.
1)
2)
3)
4)
CNE Permanent Ramona Casino
Ramona, Oklahoma
Structural and Underfloor Utilities Package
25 July 2011
221316-5
SaÌntary Waste and Vent Piping
c.
on each end,
Sleeve Materials:
For Casl-lron Soil Pipes: ASTM C 564, rubber.
For Plastic Pipes: ASTM F 477, elastomeric seal or ASTM D 5926, PVC.
For Dissimilar Pipes: ASTM D 5926, PVC or other material compatible with
pipe materials being joined.
Shielded, Nonpressure Transition Couplings:
Manufacturers: Subject to compliance with requirements, provide products by one
of the following:
Cascade Waterworks Mfg. Co,
Mission Rubber Company: a division of MCP lndustries, lnc.
Standard: ASTM C 1460.
Description: Elastomeric or rubber sleeve with fullJength, corrosion-resistant outer
d.
4.
Description: Elastomeric, sleeve-type, reducing or transition pattern. lnclude
shear ring and corrosion-resistant-metal tension band and tightening mechanism
1)
2)
3)
a.
b.
c.
1)
2)
shield and conosion-resistant-metal tension band and tightening mechanism on
5.
each end.
Pressure Transition Couplings:
Manufacturers: Subject to compliance wilh requirements, provide products by one
of the following:
Cascade Watenrorks Mfg. Co,
Dresser, lnc.
EBAA lron, lnc.
JCM lndustries, tnc,
Romac lndustries, lnc.
Smith-Blair, lnc.; a Sensus company.
The Ford Meter Box Company, lnc.
Viking Johnson.
Standard: A\^MA C219,
Description: Metal, sleeve-type same size as, with pressure rating at least equal
to, and ends compatible with, pipes to be joined.
a.
b.
c.
d.
e.
f.
B.
1)
2)
3)
4)
5)
6)
7)
8)
Center-SleeveMaterial: Manufacturer'sstandard.
Gasket Material: Natural or synthetic rubber.
Metal Component Finish: Conosion-resistant coating or material.
Dielectric Fittings:
General Requirements: Assembly of copper alloy and ferrous materials with separating
nonconductive insulating material. lnclude end connections compatible with pipes to be
1.
2.
joined.
Dielectric Unions:
a.
Manufacturers; Subject to compliance with requirements, provide products by one
of the following:
3.
1) CapitolManufacturingCompany.
2) Central Plastics Company.
3) Hart lndustries lnternational, lnc.
4) Jomar lnternational Ltd.
5) Matco-Norca, lnc.
6) McDonald, A. Y. Mfg. Co
7) Watts Regulator Co.; a division of Watts Water Technologies, lnc.
8) Wilkins; a Zurn company.
b. Description:
1) Standard: ASSE 1079.
2) Pressure Rating: 125 psig minimum at 180 deg F.
3) End Connections: Solder-joint copper alloy and threaded ferrous.
Dielectric Flanges:
GNE Permanent Ramona Casino
Ramona, Oklahoma
Structural and Underlloor Utilities Package
25 July 2011
221316-6
Saintary Waste and Vent Piping
a.
Manufacturers: Subject to compliance with requirements, provide products by one
of the following:
l) Capitol Manufacturing Company.
2) Central Plastics Company.
3) Matco-Norca, lnc.
4) Watts Regulator Co.; a division of Watts Water Technologies, lnc.
5) Wilkins; aZurn company.
b. Description:
l) Standard: ASSE 1079.
2) Factory-fabricated, bolted,companion-flangeassembly.
3) Pressure Rating: 125 psig minimum at 180 deg F.
4) End Connections: Solder-joint copper alloy and threaded fenousi threaded
4.
solder-joint copper alloy and threaded ferrous.
Dielectric-Flange lnsulatingKits:
Manufacturers: Subject to compliance with requirements, provide products by one
of the following:
Advance Products & Systems, lnc.
Calpico, lnc.
Central Plastics Company.
Pipeline Seal and lnsulator, lnc.
a.
1)
2')
3)
4)
b. Description:
1) Nonconducting materials for field assembly of companion flanges.
2) Pressure Rating: 150 psig.
3) Gasket: Neoprene or phenolic.
4) Bolt Sleeves: Phenolic or polyethylene.
5) Washers: Phenolic with steel backing washers.
5. Dielectric Nipples:
a. Manufacturers: Subject to compliance with requlrements, provide products by one
of the following:
1) Elster Perfection.
2) Grinnell Mechanical Products.
3) Matco-Norca, lnc.
4) Precision Plumbing Products, lnc.
5) Victaulic Company.
b. Description:
1) Standard: IAPMO PS 66
2) Electroplatedsteelnipple.
3) Pressure Rating: 300 psig at225 degF.
4) End Connectionsr Male threaded or grooved.
5) Lining: lnert and noncorrosive, propylene.
2.11
A.
B.
ENCASEMENT FOR UNDERGROUND METAL PIPING
Standard: ASTM A 674 or AWWA C105/A 21.5.
Material: Linear low-density polyethylene film of 0.008-inch or high-density, crosslaminated
polyethylene film of 0.004-inch minimum thickness.
C.
D.
Form: Sheet.
Color: Black.
CNE Permanent Ramona Casino
Ramona, Oklahoma
Structural and Underfloor Utilities Package
25 July 2011
221316-7
Saintary Waste and Vent Pìping
PART 3 - EXECUTION
31
EARTH MOVING
Comply with requirements for excavating, trenching, and backfilling specified in Section 312000
"Earth Moving."
PIPING INSTALLATION
3.2
Drawing plans, schematics, and diagrams indicate general location and anangement of piping
systems. lndicated locations and anangements were used to size pipe and calculate friction
loss, expansion, pump sizing, and other design considerations. lnstall piping as indicated
unless deviations to layout are approved on coordination drawings.
B
lnstall piping in concealed locations unless otherwise indicated and except in equipment rooms
and serv¡ce areas.
lnstall piping indicated to be exposed and piping in equipment rooms and servlce areas at right
angles or parallel to building walls. Diagonal runs are prohibited unless specifically indicated
otherwise.
D.
lnstall piping above accessible ceilings to allow sufficient space for ceiling panel removal.
E.
lnstall piping to permit valve servicing.
F.
lnstall piping at indicated slopes.
G.
lnstall piping free of sags and bends.
H.
lnstall fittings for changes in direction and branch connections,
t.
lnstall piping to allow application of insulation,
J.
lnstall seismic restraints on piping. Comply with requirements for seismic-restraint devices
in Section 220548 "Vibration and Seismic Controls for Plumbing Piping and
specified
Equipment."
K.
Make changes in direction for soil and waste drainage and vent piping using appropriate
branches, bends, and long-sweep bends. sanitary tees and short-sweep 1/4 bends may be
used on vertical stacks if change in direction of flow is from horizontal to vertical. Use long-turn,
double Y-branch and l/8-bend fittings if two flxtures are installed back to back or side by side
with common drain pipe. Straight tees, elbows, and crosses may be used on vent lines. Do not
change direction of flow more than g0 degrees. Use proper size of standard increasers and
reducers if pipes of different sizes are connected. Reducing size of drainage piping in direction
of flow is prohibited.
Lay buried building drainage piping beginning at low point of each system. lnstall true to grades
and alignment indicated, with unbroken continuity of invert. Place hub ends of piping upstream.
lnstall required gaskets according to manufacturer's written instructions for use of lubricants,
cements, and other installation requirements. Maintain swab in piping and pull past each joint
as completed,
GNE Permanent Ramona Casino
Ramona, Oklahoma
Structural and Underfloor Utilities Package
25 July 2O11
22't316-8
Saintary Waste and Vent Piping
M.
lnstall soil and waste drainage and vent piping
at the following minimum slopes
unless
otherwise indicated:
Building Sanitary Drain: 2 percent downward in direction of flow for piping NPS3 and
smaller; 1 percent downward in direction of flow for piping NPS 4 and larger.
Horizontal Sanitary Drainage Piping: 2 percent downward in direction of flow,
Vent Piping: 1 percent down toward vertical fixture vent ortoward vent stack.
1.
2.
3.
N.
lnstall cast-iron soil piping according to CISPI's "Cast lron Soil Pipe and Fittings Handbook,"
Chapter lV, "lnstallation of Cast lron Soil Pipe and Fittings."
lnstall encasement
underground piping according
ASTM A 674 or
AWWA C105/A21.5.
1.
on
to
o.
lnstall steel piping according to applicable plumbing code.
P.
lnstall stainless-steel piping according to ASME A112.3.1and applicable plumbing code,
o.
lnstall aboveground copper tubing according to CDA's "Copper Tube Handbook."
R.
lnstall aboveground ABS piping according to ASTM D 2661.
S.
lnstall aboveground PVC piping according to ASTM D 2665.
T.
lnstall underground ABS piping according to ASTM D 2321.
U.
lnstall engineered soil and waste drainage and vent piping systems as follows:
Combination Waste and Vent: Comply with standards of authorities having jurisdiction.
Reduced-Size Venting: Comply with standards of authorities having jurisdiction,
V
1.
2.
Plumbing Specialties:
1.
2.
lnstall backwater valves in sanitary waster gravity-flow piping. Comply with requirements
for backwater valves specifìed in Section 221319 "Sanitary Waste Piping Specialties.'
lnstall cleanouts at grade and extend to where building sanitary drains connect to building
sanitary sewers in sanitary drainage gravity-flow piping. lnstall cleanout fitting with
closure plug inside the building in sanitary drainage force-main piping. Comply with
requirements for cleanouts specifled
Section 2213'19 "Sanitary Waste Piping
Specialties."
lnstall drains in sanitary drainage gravity-flow piping. Comply with requirements for
drains specified ln Section 221319 "Sanitary Waste Piping Speciatties."
in
3.
W.
Do not enclose, cover, or put piping into operation until it is inspected and approved by
authorities having jurisdiction.
X.
lnstall sleeves for piping penetrations of walls, cailings, and floors. Comply with requirements
for sleeves specified in Section 220517 "Sleeves and Sleeve Seals for Plumbing Piping."
lnstall sleeve seals for piping penetrations of concrete slabs. Comply with requirements for
sleeve seals specified in Section 220517 "Sleeves and Sleeve Seals for Plumbing Piping,"
3.3
JOINT CONSTRUCTION
Join hub-and-spigot, cast-iron soil piping with gasket joints according to CISPI's "Cast lron Soil
Pipe and Fittings Handbook" for compression joints.
GNE Permanenl Ramona Casino
Ramona, Oklahoma
Skuctural and Underfloor Utilities Package
25 July 2011
221316-9
Saintary Waste and Vent Piping
B
Join hub-and-spigot, cast-iron soil piping with calked Joints according to CISPI's "Cast lron Soil
Pipe and Fittings Handbook" for lead-and-oakum calked joints.
c
Join hubless, cashiron soil piping according to ClSPl310 and CISPI's "Cast lron Soil Pipe and
Fittings Handbook" for hubless-piping coupling joints.
D
Threaded Joints: Thread pipe with tapered pipe threads according to ASME 81.20.1. Cut
threads full and clean using sharp dies. Ream threaded pipe ends to remove buns and restore
full lD. Join pipe fittings and valves as follows:
Apply appropriate tape or thread compound to extemal pipe threads unless dry seal
threading is specified.
Damaged Threads: Do not use pipe or pipe fittings with threads that are conoded or
damaged. Do not use pipe sections that have cracked or open welds.
1.
2.
E.
Join stainless-steel pipe and fittings with gaskels according to ASME A112.3.1.
F.
Join copper tube and fittings with soldered joints according to ASTM B 828. Use ASTM B 813,
water-flushable, lead-free ffux and ASTM B 32, lead-free-alloy solder.
(J.
Grooved Joints: Cut groove ends of pipe according to AWWA C606. Lubricate and install
gasket over ends of pipes or pipe and fitting. lnstall coupling housing sections, over gasket,
with keys seated in piping grooves. lnstall and tighten housing bolts.
H.
Flanged Joints: Align bolt holes. Select appropriate gasket material, size, type, and thickness.
lnstall gasket concentrically positioned. Use suitable lubricants on bolt threads. Torque bolts in
cross pattern.
t.
Plastic, Nonpressure-Piping, Solvent-Cement Joints: Clean and dry joining surfaces. Join pipe
and fittings according to the following:
1.
Comply with ASTM F402 for safe-handling practice of cleaners, primers, and solvent
cements.
2.
3.
34
ABS Piping: Join according to ASTM D 2235 and ASTM D 2661 Appendixes.
PVC Pipíng: Join according to ASTM D 2855 and ASTM D 2665 Appendixes.
SPECIALTY PIPE FITTING INSTALLATION
A.
B
3.5
A.
Transition Couplings:
lnstall transition couplings at joints of piping with small differences in OD's.
ln Drainage Piping: Unshielded, nonpressure transition couplings.
ln Aboveground Force Main Piping: Fitting-type transition couplings.
ln Underground Force Main Piping:
NPS 1-1l2 and Smaller: Fitting-type transition couplings.
NPS 2 and Larger; Pressure transition couplings,
1.
2.
3.
4.
a.
b,
Dielectric Fittings:
lnstall dielectric fittings in piping at connections of dissimilar metal piping and tubing
Dielecbic Fittings for NPS 2 and Smaller: Use dielectric nipples.
Dielectric Fittings for NPS 2-112to NPS 4: Use dielectric flanges.
Dielectric Fittings for NPS 5 and Larger: Use dielectric flange kits.
1.
2.
3.
4.
CONNECTIONS
Drawings indicate general arrangement of piping, fittings, and specialties.
CNE Permanent Ramona Casino
Ramona, Oklahoma
Structural and Underfloor Utilities Package
25 July 2011
221316-10
Saintary Waste and Vent Piping
B
Connect soil and waste piping to exterior sanitary sewerage piping. Use transition fitting to join
dissimilar piping materials.
c.
Connect drainage and vent piping to the following:
1.
2.
3.
4.
5.
6.
7.
Plumbing Fixtures: Connect drainage piping in sizes indicated, but not smaller than
required by plumbing code.
Plumbing Fixtures and Equipment: Connect atmospheric vent piping in sizes indicated,
but not smaller than required by authorities having jurisdiction.
Plumbing Specialties: Connect drainage and vent piping in sizes indicated, but not
smaller than required by plumbing code.
lnstall test tees (wall cleanouts) in conductors near floor and floor cleanouts with cover
flush with floor.
lnstall horizontal backwater valves with cleanout cover flush with floor.
Comply with requirements for backwater valves specified in Section221319 "Sanitary
Waste Piping Specialties."
Equipment: Connect draínage piping as indicated. Provide shutoff valve if indicated and
union for each connection. Use flanges instead of unions for connections NPS 2-112 and
larger.
D.
Make connections according to the following unless otherwise indicated:
1.
2.
36
lnstall unions, in piping NPS 2 and smaller, adjacent to each valve and at final connection
to each piece of equipment.
lnstall flanges, in piping NPS 2-112 and larger, adjacent to flanged valves and at final
connection to each piece of equipment.
IDENTIFICATION
A.
37
ldentify exposed sanitary waste and vent piping.
FIELD QUALITY CONTROL
A
During installation, notifo authorities having jurisdiction at least 24 hours before inspection must
be made. Perform tests specified below in presence of authorities having jurisdiction,
Roughing-in lnspection: Arrange for inspection of piping before concealing or closing-in
after roughing-in and before setting fixtures,
Final lnspection: Arrange for final inspection by authorities having jurisdiction to observe
tests specified below and to ensure compliance with requirements.
L
2.
B.
Reínspection: lf authorities having jurisdiction find that piping will not pass test or inspection,
make required corrections and anange for reinspection.
c.
Reports: Prepare inspection reports and have them signed by authorities having jurisdiction.
D.
Test sanitary drainage and vent piping according to procedures of authorities having jurisdiction
or, in absence of published procedures, as follows:
Test for leaks and defects in new piping and parts of existing piping that have been
altered, extended, or repaired. lf testing is performed in segments, submit separate
report for each test, complete with diagram of portion of piping tested.
Leave uncovered and unconcealed new, altered, extended, or replaced drainage and
vent piping until it has been tested and approved. Expose work that was covered or
concealed before it was tested.
1.
2.
CNE Permanent Ramona Caslno
Ramona, Oklahoma
Structural and Underfloor Utilities Package
25 July 2011
221316-11
Saintary Waste and Vent Piping
3.
4.
Roughing-in Plumbing Test Procedure: Test drainage and vent piping except outside
leaders on completion of roughing-in. Close openings in piping system and fill with water
to point of overflow, but not less than lGfoot head of water. From 15 minutes before
inspection starts to completion of inspection, water level must not drop. lnspect joints for
leaks.
Finished Plumbing Test Procedure: After plumbing fixtures have been set and traps filled
with water, test connections and prove they are gastight and watertight. Plug vent-stack
openings on roof and building drains where they leave building, lntroduce air into piping
system equal to pressure of 1-inch wg. Use U-tube or manometer inserted in trap of
water closet to measure this pressure. Air pressure must remain constant without
introducing additional air throughout period of inspection. Inspect plumbing fixture
5.
6.
E
connections for gas and water leaks.
Repair leaks and defects with new materials and retest piping, or portion thereof, until
satisfactory results are obtained.
Prepare reporls forfests and required conective action.
Test force-main piping according to procedures of authorities having jurisdiction or, in absence
of published procedures, as follows:
Leave uncovered and unconcealed new, altered, extended, or replaced force-main piping
until it has been tested and approved. Expose work that was covered or concealed
before it was tested.
Cap and subject piping to static-water pressure of 50 psig above operating pressure,
without exceeding pressure rating of piping system materials. lsolate test source and
allow to stand for four hours. Leaks and loss ln test pressure constitute defects that must
be repaired.
Repair leaks and defects with new materials and retest piping, or portion thereof, until
satisfactory results are obtained.
Prepare reports for tests and required corrective action.
1.
2.
3.
4.
38
CLEANING AND PROTECTION
A.
Clean interior of piping. Remove dirt and debris as work progresses.
B.
Protect drains during remainder of construction period to avoid clogging with dirt and debris and
to prevent damage from traffic and construction work.
c.
Place plugs in ends of uncompleted piping at end of day and when work stops.
D.
Exposed ABS Pipíng: Protect plumbing vents exposed to sunlight with two coats of waterbased latex paint.
PIPING SCHEDULE
3.9
Flanges and unions may be used on aboveground pressure piping unless otherwise indicated.
B.
Underground, soil, waste, and vent piping NPS 4 and smaller shall be the following:
Extra Heavy class, cast-iron soil piping; gaskets; and gasketed Jolnts.
1.
2.
3.
4.
5.
Hubless, cast-iron soil pipe and fittings; CISPI hubless-piping couplings; and coupled
joints.
Stainless-steel pipe and fittings, gaskets, and gasketed joints.
Solid wall ABS pipe, ABS socket fìttings, and solvent-cemented joints.
Solid wall PVC pipe, PVC socket fittings, and solvent-cemented joints.
CNE Permanent Ramona Gasino
Ramona, Oklahoma
Structural and Underfloor Utilities Package
25 July 2011
22131612
Saintary Waste and Vent Piping
6.
c
D.
Dissimilar Pipe-Material Couplings: Unshielded, nonpressure transition couplings.
Underground, soil and waste piping NPS 5 and larger shall be the following:
Extra Heavy class, cast-iron soil piping; gaskets; and gasketed joints.
Hubless, casl-iron soil pipe and fittings; CISPI hubless-piping couplings; coupled joints.
Solid-wall PVC pipe; PVC socket fittings; and solvent-cemented joints.
Dissimilar Pipe-Material Couplings: Unshielded, nonpressure transition couplings.
1.
2.
3.
4.
Underground, soil and waste - grease sanitary sewer service.
Any form of plastic pipe is not allowed,
Couplings to be tolerant of heat tracing.
lnstall Raychem 8XL1-CT cable to maintain 110'F in the pipe. Minimum two runs of
cable per length. All cable terminations to be above grade and in walls for junction boxes
to be installed at a later date. Protect exposed cable from damage.
lnstall the piping system in 5" of Gilsulate 500xa insulation on all sides. lnstall the system
per the Gilsulate installation manual.
1.
2,
3,
4.
END OF SECTION 221316
CNE Permanent Ramona Casino
Ramona, Oklahoma
Structural and Underfloor Utilities Package
25 July 2011
221316-13
Saintary Waste and Vent Piping
SECTION 221319. SANITARY WASTE PIPING SPECIALTIES
PART
1,1
A.
1
. GENERAL
RELATED DOCUMENTS
Drawings and general provisions
of the Contract, including General and
Supplementary
Conditions and Division 01 Specification Sections, apply to this Section.
1.2
A.
1.3
A.
B.
C.
D.
E.
F.
G.
1.4
A.
SUMMARY
Section lncludes:
Backwater valves,
1.
2.
3.
4.
Cleanouts.
Floor drains.
Flashing materials.
DEFINITIONS
AEIS; Acrylonitrile-butadiene-styreneplastic.
FOG: Fats, oils, and greases.
FRP; Fiberglass-reinforcedplastic.
HDPE: High-density polyethylene plastic.
PE: Polyethylene plastic.
PP: Polypropylene plastic.
PVC: Polyvinyl chloride plastic.
ACTION SUBMITTALS
Product
Data: For each type of
product indicated. lnclude rated capacities, operating
characteristics, and accessories for the following:
Greaseinterceptors.
Grease removal devices.
Oilinterceptors.
1.
2,
3.
B.
1.5
Shop Drawings: Show fabrication and installation details for frost-resistant vent terminals.
Wiring Diagrams: Power, signal, and control wiring.
1.
INFORMATIONAL SUBMITTALS
CNE Permanent Ramona Casino
Ramona, Oklahoma
Skuctural and Underfloor Utilities Package
25 July 2011
221319-1
Sanitary Waste Piping Speciatties
A.
Field quality-control test reports.
CLOSEOUT SUBMITTALS
1.6
A
17
Operation and Maintenance Data: For drainage piping specialties to include in emergency,
operation, and maintenance manuals.
QUALIry ASSURANCE
A
Drainage piping specialties shall bear label, stamp, or other markings of specified testing
agency,
Electrical Components, Devices, and Accessories: Listed and labeled as defined in NFpA 70,
Article100, by a testing agency acceptable to authorities having jurisdiction, and marked for
intended use,
Comply with NSF 14, "Plastics Piping Gomponents and Related Materials," for plastic sanitary
piping specialty components.
1.8
COORDINATION
Coordinate size and location of concrete bases. Cast anchor-bolt inserts into bases. Concrete,
reinforcement, and formwork requirements are specifled in Section 033000 'Cast-in-Place
Concrete."
Coordinate size and location of roof penetrations.
EXTRA MATERIALS
1.9
A.
Furnish extra materials described below that match products installed and that are packaged
with protective covering for storage and identified with labels describing contents.
Cultures: Provide 1-gal. bottles of bacteria culture recommended by manufacturer of
FOG disposal systems equal to 200 percent of amount installed, but no fewer than 2 1-
1'
gal. bottles.
PART 2 - PRODUCTS
2.1
A.
CLEANOUTS
Exposed Metal Cleanouts;
1.
2.
3'
Available Manufacturers: Subject to compliance with requirements, manufacturers
offering products that may be incorporated into the Work include, but are not limited to,
the following:
Manufacturers: Subject to compliance with requirements, provide products by one of the
following:
Basis-of-Design Product; Subject to compliance with requirements, provide the product
indicated on Drawings or a comparable product by one of the following:
Josam Company; Josam Div.
MIFAB, tnc.
Smith, Jay R. Mfg. Co.; Division of Smith lndustries, lnc.
a.
b.
c.
CNE Permanent Ramona Casino
Ramona, Oklahoma
Structural and Underfloor Utilities Package
25 July2O11
221319-2
Sanitary Waste Piping Speciallies
4.
E
6.
7.
8.
L
B
d.
e.
Í.
S.
Tyler Pipe; Wade Div.
Watts Drainage Products lnc.
Zurn Plumbing Products Group;Specification Drainage Operation.
JosamCompany;Blucher-JosamDiv.
Standard: ASME 4112.36.2M for cast iron for cleanout test tee.
Size: Same as connected drainage piping
Body Material: Hub-and-spigot, cast-iron soil pipe T-branch as required
connected piping.
to
match
Closure: Countersunk plug.
Glosure Plug Size: Same as or not more than one size smaller than cleanout size,
Closure: Stainless-steel plug with seal,
Metal Floor Cleanouts:
1.
2.
3.
to compliance with requirements, manufacturers
offering products that may be incorporated into the Work include, but are not limited to,
the following:
Manufacturers: Subject to compliance with requirements, provide products by one of the
following:
Basis-of-Design Product Subject to compliance with requirements, provide the product
indicated on Drawings or a comparable product by one of the following:
Josam Company; Josam Div.
Available Manufacturers: Subject
a.
b.
c.
d.
e.
f.
S.
h.
i.
j.
k.
l.
Oatey.
Sioux Chief Manufacturing Company, lnc.
Smith, Jay R. Mfg. Co.; Division of Smith lndustries, lnc.
Tyler Pipe; Wade Div.
Watts Drainage Products lnc.
Zurn Plumbing Products Group; Light Commercial Operation.
Zurn Plumbing Products Group; Specification Drainage Operation.
Josam Company; Josam Div.
Kusel Equipment Co.
Smith, Jay R. Mfg. Co.; Division of Smith lndustries, lnc.
JosamCompany;Blucher-JosamDiv.
4. Standard: ASME A1 12.36.2M for adjustable housing cleanout.
5. Size: Same as connected branch.
6. Type: Adjustable housing.
7. Body or Ferrule: Cast iron.
8. Clamping Device: Not required.
L Outlet Connection: lnside calk.
10. Closure: Brass plug with straight threads and gasket.
11. Adjustable Housing Material: Cast iron Plastic with threads.
12. Frame and Cover Material and Finish: Nickel-bronze, copper alloy.
13. Frame and GoverShape: Round.
14. Top Loading Classifìcation: Extra Hearry Duty.
'15. Riser:
ASTMA74, Êxlra-Heavy class, casl-iron drainage pipe fltting and riser to
cleanout.
16. Standard: ASME A112.3.1.
17. Size: Same as connected branch.
18. Housing: Stainless steel.
19. Closure: Stainless steel with seal.
20. Riser: Stainless-steel drainage pipe fitting to cleanoul.
22
FLOOR DRAINS
A.
Cast-lron Floor Drains:
CNE Permanent Ramona Casino
Ramona, Oklahoma
Structural and Underfloor Utilities Package
25 July 2011
221319-3
Sanitary Waste Piping Specialties
1.
2.
3.
Available Manufacturers: Subject to compliance with requirements, manufacturers
offering products that may be incorporated into the Work include, but are not limited to,
the following:
Manufacturers: Subject to compliance with requirements, provide products by one of the
following:
Basis-of-Design Product: Subject to compliance with requlrements, provide the product
indicated on Drawings or a comparable product by one of the following:
Commercial Enameling Co.
Josam Company; Josam Div.
a.
b.
c.
d.
e.
f.
s.
h.
t.
MIFAB,lnc.
Prier Products, lnc.
Smith, Jay R. Mfg. Co.; Division of Smith lndustries, tnc.
Tyler Pipe; Wade Div.
Watts Drainage Products lnc.
Zurn Plumbing Products Group; Light Commercial Operation.
Zurn Plumbing Products Group; Specification Drainage Operatíon.
4. Standard: ASME 4112.6.3.
5. Pattern: Area drain.
6. Body Material: Gray iron.
7. Seepage Flange: Not required.
8. Anchor Flange: Not required,
9. Clamping Device: Not required.
10. Outlet: Bottom.
11. Backwater Valve: Dräin-outlet type.
12. coating on lnterior and Exposed Exterior sudaces: Acid-resistant enamel.
'13, Sediment Bucket: Not requíred.
14. Top or Strainer Material: Bronze.
15. Top of Body and Strainer Finish: Nickel bronze.
16. Top Shape: Round.
17. Iop Loading Classification: Light Duty.
18. Funnel: Not required.
19. lnlet Fitting: Not required.
20. Trap Material: Bronze.
21. Trap Pattern: Standard P-trap.
2.3
GREASE INTERCEPTOR
A.
Provide a grease interceptor and accessories. See drawings for details.
PART 3 - EXECUTION
3.1
A.
INSTALLATION
lnstall cleanouts in aboveground piping and building drain piping according to the following,
unless otherwise indicated:
Size same as drainage piping up to NPS 4. Use NPS 4 for larger drainage piping unless
larger cleanout is indicated.
Locate at each change in direction of piping greater than 45 degrees.
Locate at minimum intervals of 50 feet for piping NPS 4 and smaller and 100 feet for
1.
2.
3.
4.
larger piping.
Locate at base of each vertical soil and waste stack.
GNE Permanent Ramona Casino
Ramona, Oklahoma
Structural and Underf,oor Utilities Package
25 July 2O11
2213194
Sanitary Waste Piping Specialties
B.
c
For floor cleanouts for piping below floors, install cleanout deck plates with top flush with
finished floor.
For cleanouts located in concealed piping, install cleanout wall access covers, of types
indicated, with frame and cover flush with fìnished wall.
D
lnstall floor drains at low points of surface areas to be drained. Set grates of drains flush with
fìnished floor, unless othenruise indicated.
Position floor drains for easy access and mainlenance.
Set floor drains below elevation of sunounding finished floor to allow floor drainage. Set
wilh grates depressed according to the following drainage area radii:
Radius, 30 lnches or Less: Equivalent to 1 percent slope, but not less than 114-
1.
2.
a.
b.
c.
3.
4.
E.
inch total depression.
Radius, 30 to 60 lnches: Equivalent to I percent slope.
Radius, 60 lnches or Larger: Equivalent to 1 percent slope, but not greater than 1inch total depression.
lnstall floor-drain flashing collar or flange so no leakage occurs between drain and
adjoining flooring. Maintain integrity of waterproof membranes where penetrated,
lnstall individual traps for floor drains connected to sanitary building drain, unless
otherwise indicated,
lnstall trench drains at low points of surface areas to be drained. Set grates of drains flush with
nished surface, u nless otherwise ind icated.
fi
F
Assemble and install ASME A1 12.3.1, stainless-steel channel drainage systems according to
ASME A112.3.1. lnstall on support devices so that top will be flush with surface.
G.
Assemble non-ASME A112.3.1, stainless-steel channel drainage system components according
to manufacturer's written instructions. lnstall on support devices so that top will be flush with
adjacent surface.
H.
Assemble FRP channel drainage system components according to manufacturer's written
instructions. lnstall on support devices so that top will be flush with adjacent surface.
t.
Assemble plastic channel draínage system components according to manufactureds written
instructions. Install on support devices so that top will be flush with adjacent surface,
lnstall floor-drain, trap-seal primer fittings on inlet to floor drains that require trap-seal primer
connection.
1
Exception: Fitting may be omitted if trap has trap-seal primer connection.
Size: Same as floor drain inlet.
.
2.
K.
lnstall traps on plumbing specialty drain outlets.
CONNECTIONS
3.2
A.
Comply with requirements in Section 221316 "Sanitary Waste and Vent Piping" for piping
installation requiremenls. Drawings indicate general arrangement of piping, fittings, and
specialties.
B
lnstall piping adjacent to equipment to allow service and maintenance.
CNE Permanent Ramona Casino
Ramona, Oklahoma
Structural and Underfloor Utilíties Package
25 July 2011
221319-5
Sanitary Waste Piping Specialties
3.3
A.
3.4
A,
B.
3.5
A.
B.
GREASE INTERCEPTOR
lnstall per the manufacturer's instructions.
FIELD QUALITY CONTROL
Perform tests and inspections and prepare test reports.
L
Manufacture/s Fleld Service: Engage a factory-authorized service representative to
inspect fìeld-assembled and their installation, including piping and electrical connections,
and to assist in testing.
Tests and lnspections:
Leak TesÍ After installation, charge system and test for leaks. Repair leaks and retest
until no leaks exist.
Test and adjust controls and safeties. Replace damaged and malfunctloning controls
and equipment.
1.
2.
PROTECTION
Protect drains during remainder of construction period to avoid clogging with dirt or debris and
to prevent damage from tratfic or construction work.
Place plugs in ends of uncompleted piping at end of each day or when work stops.
END OF SECTION 221319
GNE Permanent Ramona Gasino
Ramona, Oklahoma
Structural and Underfloor Utilities Package
25 July 2O11
2213'19-6
Sanitary Waste Piping Specialtìes
SECTION 31 3116 - TERMITE CONTROL
PART 1 - GENERAL
1.1
A.
1.2
A.
SUMMARY
Section lncludes:
Soil treatment with termiticide.
1.
SUBMITTALS
Product
Data: For each type of product indicated. lnclude the EPA-Registered Labelfor
termiticide products.
B.
C.
Product ceftificates.
Soil Treatment Application Repoft: lnclude the following:
'1. Date and time of application.
2.
3.
4.
5,
6.
7.
D.
1.3
A.
B.
1.4
A.
Moisture content of soil before application.
Termiticide brand name and manufacturer.
Quantity of undiluted termiticide used.
Dilutions, methods, volumes used, and rates of application.
Areas of application.
Water source for application.
Warranties: Sample of special warranties.
QUALITY ASSURANCE
lnslaller Qualifications: A specialist who is licensed according to regulations of authorities
having jurisdiction to apply termite controltreatment and products in jurisdiction where Project
is located and who employs workers trained and approved by manufacturer to install
manufacturer's products.
Regulatory Requirements: Formulate and apply termiticides and termiticide devices according
to the EPA-Registered Label,
PROJECT CONDITIONS
Environmental Limitations: To ensure penetration, do not treat soil that is water saturated or
lrozen. Do not treat soil while precipitation is occurring. Comply with requirements of the
EPA-Registered Label and requirements of authorities having jurisdiction.
B.
Coordinate soiltreatment application with excavating, filling, grading, and concreting
operations, Treat soil under footings, grade beams, and ground-supported slabs before
construction.
CNE Permanent Ramona Casino
Ramona, Oklahoma
Struclural and Underfloor Utilities Package
25 July 2011
3'1 3116-1
Termite Gontrol
WARRANTY
1.5
A
Soil Treatment Special Warranty: Manufacture/s standard form, signed by Applicator and
Contractor, certifying that termite control work, consisting of applíed soiltermiticide treatment,
will prevent infestatíon of subterranean termites. lf subterranean termite activity or damage is
discovered during warranty period, re-treat soil and repair or replace damage caused by termite
infesìation.
Warranly Period: Five years from date of Substantial Completion.
1.
PART2 - PRODUCTS
2,1
A.
SOIL TREATMENT
Termiticide: Provide an EPA-Registered termiticide, complying with requirements of
authorities having jurisdiction, in an aqueous solution formulated to prevent termite infestation.
Provide quantity required for application at the label volume and rate for the maximum
termilicide concentration allowed for each specific use, according to product's EPA-Registered
Label.
PARTs - EXECUTION
APPLICATION, GENERAL
3.1
A.
General: Comply with the most stringent requirements of authorities having jurisdiction and
with manufacturer's EPA-Registered Label for products.
APPLYING SOIL TREATMENT
3.2
A.
Examine substrates, areas, and conditions, with Applicator present, for compliance with
requirements for moisture content of soil per termiticide label requirements, interfaces with
earthwork, slab and foundation work, landscaping, utility installation, and other conditions
affecting performance of termite control.
B.
Proceed with application only after unsatisfactory conditions have been corrected.
c.
Soil Treatment Preparation: Remove foreign matter and impermeable soil materials that could
decrease treatment effectiveness on areas to be treated. Loosen, rake, and level soil to be
treated except previously compacted areas under slabs and footings. Termiticides may be
applied before placing compacted fill under slabs if recommended in writing by termiticide
manufacturer.
Fit filling hose connected to water source at the site with a backflow preventer, complying
with requirements of authorities having jurisdiction.
1.
D.
Application: Mix soiltreatment termiticide solution to a uniform consistency, Provide quantity
required for application at the label volume and rate for the maximum specified concentration of
termiticide, according to manufacturer's EPA-Registered Label, to the following so that a
continuous horizontal and verticaltermiticidal barrier or treated zone is established around and
under building construction. Distribute treatment evenly.
GNE Permanent Ramona Casino
Bamona, Oklahoma
Structural and Underfloor Utilities Package
25 July 2011
31 31 16-2
Termite Gontrol
1.
2.
3.
4.
Slabs-on-Grade and Basement Slabs: Under ground-supported slab construction,
including footings, building slabs, and attached slabs as an overall treatment. Treat soil
materials before concrete footings and slabs are placed,
Foundations: Adjacent soil, including soil along the entire inside perimeter of foundation
walls; along both sides of inlerior partition walls; around plumbing pipes and electric
conduit penetrating the slab; around interior column footers, piers, and chimney bases;
and along the entire outside perlmeter, from grade to bottom of footing. Avoid soil
washout around footings.
Crawlspaces: Soil under and adjacent to foundations as previously indicated. Treat
adjacent areas including around entrance platform, porches, and equipment bases.
Apply overall treatment only where attached concrete platform and porches are on fill or
ground.
Penetrations: At expansion joints, control joints, and areas where slabs will be
penetrated.
E.
F.
Avoid disturbance of treated soil after application. Keep off treated areas until completely dry.
G.
H.
Post warning signs in areas of application
Protect termiticide solution, dispersed in lreated soils and fills, from being diluted until
ground-supported slabs are installed. Use waterproof barrier according to EPA-Registered
Label instructions.
Reapply soil treatment solution to areas disturbed by subsequent excavation, grading,
landscaping, or other conslruction activities following application.
END OF SECTION 31 3116
CNE Permanent Ramona Casino
Bamona, Oklahoma
Structural and Underlloor Utilities Package
25 July 2011
31 31 16-3
Termile Control
Download