INTRODUCING A GFCI RECEPTACLE THAT TESTS ITSELF.

advertisement
pass & seymour ®
Self-Test GFCI Receptacle
Introducing a GFCI
receptacle that
tests itself.
GFCI receptacles are designed to save lives. Yet,
the simple task of testing them on a regular basis
is often overlooked. That’s why we created one
that actually tests itself.
The new Pass & Seymour Self-Test GFCI with
SafeLock Protection™ conducts an automatic test
every second, ensuring it’s always ready to protect.
If the device fails the test, the indicator light flashes
to signal that the GFCI should be replaced. It also
has our proven SafeLock Protection feature: if
critical components are damaged and protection
is lost, power to the receptacle will be locked out.
The Pass & Seymour Self-Test GFCI Receptacle is
ideal for kitchens, bathrooms, garages, basements
and other areas where the risk of electrical shock
exists. It’s just the latest innovation designed for
1596TRLA
Prevents the unsafe condition
of power without protection.
you, from the company that developed the first
GFCI receptacle.
Self-Test GFCI Receptacle
Auto-Ground clip assures a
positive ground to metal box.
Self-Test GFCI with SafeLock™
Protection — conducts an automatic
test every second, ensuring it’s
always ready to protect. If critical
components are damaged and
protection is lost, power to the
receptacle will be locked out.
Tamper-Resistant: Automatic
shutter system prevents young
children from inserting common
objects such as hairpins or keys.
Indicator light makes it easy
to identify status.
Ground terminal back-wire
clamp for fast installation.
The most durable GFCI
receptacle available —
Exceeds UL943 voltage surge
requirements; survives 100X
the required UL 3kA/6kV
voltage surge test cycles.
Side or internal screw-pressure
plate back-wire termination speeds
installation; takes #14-#10 AWG
stranded or solid, copper or
copperclad conductors.
Two back-wire holes per termination
add wiring flexibility, eliminate
pigtailing, and save box space.
PART NO.
DESCRIPTION
1596TR*
TradeMaster Tamper-Resistant Duplex
High-impact-resistant,
thermoplastic construction
for superior strength and
durability.
1596TRLA
RATINGS
A.
V.
15
125
Colors
NEMA
Config.
I, LA, W
5-15R
*Color Designation
I
LA
W
2096TR*
Spec Grade Tamper-Resistant Duplex
20
125
I, LA, W
5-20R
RED
2096*
Spec Grade Duplex
20
125
I, LA, W, GRY, -
5-20R
–
2096HG*
Hospital Grade Duplex
20
125
I, LA, W, GRY, RED, -
5-20R
2096HGTR*
Hospital Grade Tamper-Resistant Duplex
20
125
I, LA, W
5-20R
GRY
Ivory
Light Almond
White
Red
Brown
Gray
All GFCIs are Fed Spec, FSUL Listed.
Electrical Wiring Systems
P.O. Box 4822
Syracuse, NY 13221-4822
800.776.4035
www.legrand.us/PassandSeymour
570 Applewood Crescent
Vaughan, Ontario L4K 4B4
905.738.9195
www.legrand.ca
FOLLOW US
©2013 Legrand SS1822 All Rights Reserved 06|13 EMA/CGXTP