Embedded Power for Business-Critical Continuity ARTESYN LPS120 SERIES 120 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.29” Rev. 09.15.09_12 LPS120 Series 1 of 3 LPS120 Series 120 Watts Total Power: Input Voltage: # of Outputs: 80-130Watts 85-264VAC Single Special Features •Activepowerfactorcorrection •3”x5”footprint •Lessthan1Uhigh •EN61000-3-2compliant •Remotesense •Powerfailandremoteinhibit •Singlewirecurrentsharing •Adjustablemainoutput •Built-inClassBEMIfilter •Overvoltageprotection •Overloadprotection •Thermaloverloadprotection •5VStandbyoutput and12VFanoutput Electrical Specifications Input Inputrange: Frequency: Inrushcurrent: Efficiency: EMI/RFI: Powerfactor: Safetyground leakagecurrent: 85-264VAC;127-300VDC 47-440Hz 40Amax.,coldstart@25°C 80% typical at full load FCCClassBconducted;CISPR22ClassBconducted;EN55022ClassBconducted;VDE0878PT3ClassBconducted 0.99typical 0.5mA@50/60Hz,264VACinput Output Maximumpower: Adjustmentrange: Fanoutput: Standbyoutputs: 80Wforconvection;130Wwith30CFMforcedair ±5%minimumonthemainoutputs 12V@500mA-5%,+7% 5V@500mA±5% Hold-uptime: 20ms@125Wload,120VACinput Overloadprotection: Shortcircuitprotectiononalloutputs.Caseoverloadprotected@ 120-135%aboverating Overvoltageprotection: 20-35%abovenominaloutput Remotesense: Compensatesfor0.5Vleaddropmax.Willoperatewithoutremotesense connected.Reverseconnectionprotected. LogicalControl Safety TUV: 60950 UL: 60950 CSA 60950 NEMKO: 60950 AUSTEL:60950 CB: Certificate and report CE: Mark(LVD) Powerfailure: Remoteinhibit: Remotesense: TLlogicsignalgoeshigh100-500msecaftermainoutput;itgoeslowat T least4msecbeforelossofregulation Requiresacontactclosuretodisabletheoutputs,except5Vstandby. ompensatesfor0.5Vleaddropmin.Willoperatewithoutremotesense C connected.Reverseconnectionprotected. Specifications are subject to change without notice. It is responsibility of each customer to thoroughly test each product and part number under their unique parameters and environments to ensure a product will work properly and reliably. Click below for more details, to buy on-line or request volume pricing: http://power.sager.com/artesyn-lps120-power-supply.html (866) 588-1750 p o w e r @ s a g e r. c o m h t t p : / / p o w e r. s a g e r. c o m ARTESYN LPS120 SERIES 120 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.29” Rev. 09.15.09_128 LPS120 Series 2 of 3 EnvironmentalSpecifications Operatingtemperature: SK1 0.15" DIA. 4 places (4.0) NEUTRAL MTBFdemonstrated Operating;non-condensing 10%to95%RH IEC68-2-6tothelevelsof IEC721-3-2 >550,000hoursatfullloadand 25°Cambientconditions LIVE Vibration: 3.00 (76.2) 2.55 (64.8) EARTH Humidity: -40°Cto+85°C DesignedtomeetEN61000-4; -2,-3,-4,-5,-6,-8,-11Level3 P1 Storagetemperature: Electromagnetic susceptibility: 0°to50°Cambientderateeach MechanicalDrawing outputas2.5%perdegreefrom 50°to70°C.-20°Cstartup 5.00 (127.0) 4.55 (115.6) 1 2 SK3 M3.5 (2 places) SK2 V Adjust POT 1.29 (32.8) 5 1 6 10 SK3 0.20" (5) Specifications are subject to change without notice. It is responsibility of each customer to thoroughly test each product and part number under their unique parameters and environments to ensure a product will work properly and reliably. Click below for more details, to buy on-line or request volume pricing: http://power.sager.com/artesyn-lps120-power-supply.html (866) 588-1750 p o w e r @ s a g e r. c o m h t t p : / / p o w e r. s a g e r. c o m Business-Critical Continuity ARTESYN LPS120 SERIES 120 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.29” Americas OrderingInformation Model Number Output Voltage Minimum Load Maximum Load with Convection Cooling Maximum Load with 30CFM Peak Load Regulation2 Forced Air LPS121 3.3V 0A 21A 36A 29A ± 2% 50mV LPS122 5V 0A 16A 26A 29A ± 2% 50mV LPS123 12V 0A 6.7A 10.8A 12.8A ± 2% 120mV LPS124 15V 0A 5.3A 8.7A 10.0A ± 2% 150mV LPS125 24V 0A 3.4A 5.4A 6.3A ± 2% 240mV LPS128 48V 0A 1.7A 2.7A 3.2A ± 2% 480mV Ripple P/P (PARD)3 1.Peakcurrentlasting<30secondswithamaximum10%dutycycle. 2.At25°Cincludinginitialtolerance,linevoltage,loadcurrentsandoutputvoltagesadjustedtofactorysettings. 3.Peak-to-peakwith20MHzbandwidthand10µF(tantalumcapacitor)inparallelwitha0.1µFcapacitoratratedlinevoltageandloadranges. 4.Wheninparallela10%loadisrequiredforeachpowersupply. PinAssignments ConnectorLPS120 5810VanAllenWay Carlsbad,CA92008 USA Telephone:+17609304600 Facsimile:+17609300698 Rev. 09.15.09_12 LPS120 Series 3 of 3 Europe (UK) Waterfront Business Park MerryHill,Dudley WestMidlands,DY51LX UnitedKingdom Telephone:+44(0)1384842211 Facsimile:+44(0)1384843355 Asia (HK) 14/F,LuPlaza 2WingYipStreet KwunTong,Kowloon HongKong Telephone:+85221763333 Facsimile:+85221763888 SK1 Pin1Neutral Pin3Line Forglobalcontact,visit: SK2 TB-1COMMON TB-2Mainoutput techsupport.embeddedpower @emerson.com SK3 Pin1+V1Remotesense Pin2-V1Remotesense Pin3+Remoteinhibit Pin4-Remoteinhibit Pin5+Powerfail Pin6Common Pin7SWP Pin8+12V Pin912Vcommon Pin10+5Vstandby Whileeveryprecautionhasbeentakentoensure accuracyandcompletenessinthisliterature,Emerson NetworkPowerassumesnoresponsibility,anddisclaims allliabilityfordamagesresultingfromuseofthis informationorforanyerrorsoromissions. Mating Connectors (SK1)ACInput: Molex09-50-8031(connector)08-52-0113(pins) (SK2)DCOutput:Molexseries19141-0058/0063Spadelug (SK3)ControlSignals: Molex90142-0010(USA) PINS:90119-2110or Amp:87977-3 PINS:87309-8 EmersonNetworkPowerConnectorKit#70-841-020,includesalloftheabove. Notes: 1.Specificationssubjecttochangewithoutnotice. 2.Alldimensionsininches(mm),toleranceis±.02”. 3.mountingholesMH1,MH2,MH3shouldbegroundedfor EMIpurpose 4.MountingMH1issafetygroundconnection 5.Specificationsareforconvectionratingatfactorysettings at115VACinput25°Cunlessotherwisestated. 6.Thispowersupplyrequiresmountingonmetalstandoffs 0.20”(5m)inheight. 7.Warranty:2year 8.Weight:0.71lb./0.32kg www.PowerConversion.com Emerson Network Power. Thegloballeaderinenabling business-criticalcontinuity. ACPower Connectivity DCPower EmbeddedComputing Embedded Power Monitoring OutsidePlant PowerSwitching&Controls PrecisionCooling Racks&IntegratedCabinets Services SurgeProtection EmersonNetworkPower.com EmersonNetworkPowerandtheEmerson NetworkPowerlogoaretrademarksand servicemarksofEmersonElectricCo. ©2009EmersonElectricCo. Specifications are subject to change without notice. It is responsibility of each customer to thoroughly test each product and part number under their unique parameters and environments to ensure a product will work properly and reliably. Click below for more details, to buy on-line or request volume pricing: http://power.sager.com/artesyn-lps120-power-supply.html (866) 588-1750 p o w e r @ s a g e r. c o m h t t p : / / p o w e r. s a g e r. c o m