G-Beam Series GB35B General Illumination - Suspended, Wall Mount Bi-directional Distribution OPEN 5" Click Photo to view product page Click or scan QR code to view latest spec sheet. Page 2 Page 3 Page 4 Page 5 ASL 3" Specifications Photometric Report Mounting Details Standard Colors Chart Gammalux Lighting Systems reserves the right to change details of fixture designs and construction at any time. GB35B-1/1T5 or T5HO-OP/ASL Product Overview (for complete specifications, see page 2) Construction: Extruded aluminum housing is available in standard lengths up to 16’. Continuous runs have hairline joints with no light leak. Runs of fixtures can be built to lengths matching field conditions. Electrical: Gammalux products are UL and cUL listed with quick electrical connectors and ballasts by OSRAM SYLVANIA or equal. Runs of fixtures are tested as a complete system prior to shipping. Lamp Stagger: Fluorescent lamps can be staggered for consistent illumination in continuous runs with no dark ends. ASLMD or ASLHD lens is recommended. Optical: Reflectors are formed diffuse aluminum. Lower reflectors are formed to provide even washing of light across the lens. Lenses available in standard (ASL), medium (ASLMD), and heavy diffusion (ASLHD) in lower lamp chamber. Optional dust cover (DC) available for upper lamp chamber. Finish/Color: High quality paint finish in high gloss or semi-gloss. Custom colors available. Packing and Shipping: Our packing, labeling and shipping systems ensure products arrive safely, ready to install. Standard Nomenclature Manufacturer Gammalux Cross Section (nom) 3.00” x 5.00” No. of Lamps 1/1 Distribution B Bi-directional GB35B - Lamp Type T5 T5HO 1/128T5ST Cross Section Shape Beam Nominal Lamp Watts 28 (4’-T5) 54 (4’-T5) LED available (consult factory) - Mounting Method C Cable S Swivel Stem SEQ CA Earthquake Stems/fittings WM Wall Mount, Flush WSP Wall Spacer, 1/2” Ballast ERS Electronic Rapid Start<10% THD DIM Dimming (consult factory) 120V Voltage 120, 277, UNIV Lamp Configuration Blank Non-Staggered ST add for Staggered Lamp Configuration*. - ERS - Fixture Length 4’ to 16’ units available. Consult factory for other lengths. For multiple units coupled end to end, specify total length followed by ROW. 4’ - Upper Shielding OP Open DC Dust Cover, Clear C24” (if suspended) Suspension Length Blank for Wall Spacer, and Wall Mount. 24” (Ceiling to top of fixture) - Options GLR Fuse w/holder BPE Battery Pack EM. Kit DL UL Damp Label EMERG Emergency ckt. 2CKT Dual Circuiting Paint Finish H High Gloss SG Semi-Gloss OP/ASL Lower Shielding ASL Acrylic Satin Lens ASLMD Acrylic Satin Lens, Medium Diffuse ASLHD Acrylic Satin Lens, Heavy Diffuse - WH - XX Paint Colors W White (Consult Color Chart for other standard colors) CCM Custom Color Match. *When Staggering lamps, ASLMD or ASLHD lens is recommended. GAMMALUX Lighting Systems 248 East Arrow Highway, San Dimas, CA 91773 Tel 909.599.9669 800.356.3275 Fax 909.599.5288 E-mail: info@gammalux.com Gammalux products comply with ARRA Buy American requirements. 1 G-Beam Series GB35B General Illumination - Suspended, Wall Mount Bi-directional Distribution Specifications Construction Housing: Extruded aluminum body 3.00” wide x 5.00” high, 6063T5, 0.070” minimum thickness. Available in one piece, unbroken lengths up to 16’. Joiner System: Automatic alignment, no loose parts, one tool to tighten two factory installed bolts for hairline seam. No light leaks. Fixtures that are built for continuous runs and patterns are assembled into a complete pattern and tested for fit and finish at the factory prior to being individually packed and shipped. Mounting: Aircraft cable is 7 x 7 stranded stainless steel with machined stainless steel stopper fitting at the top end (specify C). Lower end strands are welded and grounded for easy insertion into continuously adjustible cable gripper. Feed cord straight, white 3/C SVT or SJT #18 AWG. Stems are 3/8” schedule 40 pipe with top swivels (specify S). California UBC compliant stems with internal safety cables available (specify SEQ). Wall Spacer mounting (specify WSP) allows projection from wall of 3.50” to meet ADA compliant requirements. Housing can be mounted direct to wall (specify WM). Electrical Ballast: OSRAM SYLVANIA or equal Electronic Rapid Start ballast with less than 10% Total Harmonic Distortion is standard (specify ERS). Additional ballast options are available. UL listed wiring and components throughout. Housing wired with quick-connect plugs at all mating joints and individually tested. Max ballast cross section size 1.7” x 1.2”. Fixtures that are built for individual use or continuous runs and patterns are assembled into a complete pattern and tested with lamps at the factory prior to being individually packed and shipped. All fixtures bear UL & cUL Dry Location labels. Damp Location labels are available (specify DL in the options field). Lamp Stagger (when specified) Fluorescent lamps are custom-staggered in the lower lamp chamber per exact run length, providing consistent illumination from end to end in each run. Telescoping modules are not acceptable. Factory-engineered drawings indicate the location of each lamp in continuous runs and the dimensioned detail of lamp stagger. Specify ST lamp configuration. Optical Performance Reflectors: Shall be diffused formed high reflectance aluminum. Dust Cover: Clear acrylic dust cover, snap-in fitting (specify DC). Acrylic Satin Lens: Shall be 15% DR acrylic (specify ASL). Acrylic Satin Lens, Medium Diffuse: Shall be 15% DR acrylic (specify ASLMD). Multiply efficiency by .93. Acrylic Satin Lens, Heavy Diffuse: Shall be 15% DR acrylic (specify ASLHD). Multiply efficiency by .68. Performance: Independent photometric laboratory testing - ITL or equal - is required. Luminaire is a minimum of 85.8% efficient. Finish Housing assembly is electrostatically sprayed with high solids aliphatic two component polyurethane to an average thickness of 2 mils. over acid etching primer. High gloss or semi-gloss are standard. Specify H for high gloss in Paint Finish field. Specify SG for semigloss. Consult with factory for other finishes. Packing and Shipping Fixtures built for continous rows and patterns are given a specific location identifier, clearly identified on factory layout drawings provided to installing contractor. Location identifier is printed on the fixture’s ID Label, protective wrapping and on each end of fixture carton. Shipping pallets are built with 2” clearence, extending beyond the length and width of cartons, providing shipping protection. GAMMALUX Lighting Systems 248 East Arrow Highway, San Dimas, CA 91773 Tel 909.599.9669 800.356.3275 Fax 909.599.5288 E-mail: info@gammalux.com Gammalux products comply with ARRA Buy American requirements. 2 OPEN G-Beam Series GB35B 5" General Illumination - Suspended, Wall Mount Bi-directional Distribution Photometric Report IESNA: LM-63-2002 ASL ISSUE DATE: 07/10/12 3" TEST: 1 TESTLAB: PHOTOTOPIA 3.2.6 SEE: WWW.LTIOPTICS.COM/IES MANUFAC: GAMMALUX LIGHTING SYSTEMS LUMCAT: GB35B-1/154T5HO-OP/ASL-4’ LUMINAIRE: EXTRUDED ALUMINUM HOUSING WITH WHITE PAINTED GENERAL INTERIOR FINISH AND FABRICATED METAL END PIECES, FORMED PEENED METAL UPPER REFLECTOR WITH PREMIUM SPECULAR FINISH, FORMED SEMI-SPECULAR METAL LOWER REFLECTOR, FLAT FROSTED ACRYLIC LOWER DIFFUSER, OPEN TOP. LAMP: 1/1 FLUOR. 54W 4' SILHOUETTE T5 HO Summary Data EFFICIENCY (Total): EFFICIENCY (Downlight): EFFICIENCY (Uplight): CIE CLASSIFICATION: SPACING CRITERION (0-Deg.): SPACING CRITERION (90-Deg.): LUMENS/LAMP: NO. OF LAMPS: LUMINOUS OPENING: Width: Length: Height: INPUT WATTS: Average Luminance (Candelas / Square Meter) Angle 0 45 55 65 75 85 0 19596 16709 14397 10811 5779 1318 22.5 19596 9828 7073 4079 1655 254 45 19596 6623 4011 2074 838 137 85.8% 40.2 45.7% GENERAL DIFFUSE 1.29 1.19 5000 2 RECTANGULAR 0.25 (Feet) 3.83 0.45 118 Zonal Lumen Summary % Lamp 13.5 21.8 35.0 5.1 40.2 45.7 85.9 Lumens 1353.3 2177.2 3504.3 512.0 4016.4 4568.9 8585.2 Zone 0-30 0-40 0-60 60-90 0-90 90-180 0-180 Candela Plot 170 160 150 % Luminaire 15.8 25.4 40.8 6.0 46.8 53.2 100.0 140 130 2000 1000 110 100 90 80 1000 67.5 19596 5014 2859 1517 615 94 120 90 19596 4655 2621 1389 582 89 70 60 2000 10 20 30 40 Quadralaterally Symmetric Dashed: 0 Degrees Solid: 90 Degrees 50 Coefficient of Utilization Table Effective Floor Cavity Reflectance = 20% Pcc... Pw... RCR 0 1 2 3 4 5 6 7 8 9 10 70 .91 .84 .77 .70 .64 .59 .55 .51 .47 .44 .41 50 .91 .80 .71 .63 .56 .50 .45 .40 .37 .33 .31 80 30 .91 .77 .66 .57 .49 .43 .38 .34 .30 .27 .25 10 .91 .74 .62 .52 .44 .38 .33 .29 .26 .23 .21 70 .84 .77 .70 .64 .59 .54 .50 .46 .43 .40 .38 GAMMALUX Lighting Systems 50 .84 .74 .65 .58 .51 .46 .41 .38 .34 .31 .29 70 30 .84 .71 .61 .53 .46 .40 .35 .32 .28 .26 .23 10 .84 .69 .57 .48 .41 .36 .31 .27 .24 .22 .20 50 .70 .62 .55 .49 .44 .39 .35 .32 .29 .27 .25 50 30 .70 .60 .52 .45 .39 .35 .31 .28 .25 .22 .20 10 .70 .59 .49 .42 .36 .31 .27 .24 .22 .19 .17 50 .57 .51 .46 .41 .36 .33 .30 .27 .25 .23 .21 30 30 .57 .50 .43 .38 .33 .29 .26 .24 .21 .19 .18 10 .57 .49 .41 .36 .31 .27 .24 .21 .19 .17 .15 50 .46 .41 .37 .33 .30 .27 .24 .22 .21 .19 .18 10 30 .46 .40 .35 .31 .27 .24 .22 .20 .18 .16 .15 10 .46 .40 .34 .29 .26 .23 .20 .18 .16 .15 .13 0 0 .40 .35 .30 .26 .23 .20 .18 .16 .14 .13 .12 248 East Arrow Highway, San Dimas, CA 91773 Tel 909.599.9669 800.356.3275 Fax 909.599.5288 E-mail: info@gammalux.com Gammalux products comply with ARRA Buy American requirements. 3 G-Beam Series GB35B General Illumination - Suspended, Wall Mount Bi-directional Distribution Mounting Details Factory Drawings: Fully dimensioned factory drawings will be provided upon receipt of purchase order. Cable Mount: Specify C code in catalog # Swivel Stem Mount: Specify S code in catalog # CEILING LINE CEILING LINE CEILING LINE CABLE & CORD 2' LENGTH OPEN CA Earthquake Stem Mount: Specify SEQ code in catalog # CA, EARTHQUARE STEMS/FITTINGS 2' LENGTH STEM PENDANT 2' LENGTH SWIVEL AXIS OPEN OPEN 5" 5" ASL 5" 3" ASL Wall Mount: Specify WM code in catalog # WALL LINE ASL 3" 3" Wall Spacer Mount: Specify WSP code in catalog # OPEN 1/2" 3" OPEN 1 7/8" CL 5" 2 3/4" 5" MTG. POINT MTG. POINT ASL 3" ASL WALL BRACKET SPACER (ADJUSTABLE) WALL LINE Gammalux Lighting Systems reserves the right to change details of fixture design and construction at any time. GAMMALUX Lighting Systems 248 East Arrow Highway, San Dimas, CA 91773 Tel 909.599.9669 800.356.3275 Fax 909.599.5288 E-mail: info@gammalux.com Gammalux products comply with ARRA Buy American requirements. 4 G-Beam Series GB35B General Illumination - Suspended, Wall Mount Bi-directional Distribution Standard Colors/Finishes Due to variances in computer monitors and color printers, this page should be used for general reference only. For a sheet of physical color samples, please consult factory. High Gloss Finish White (WH) Red (RH) Blue (BH) Black (BKH) Yellow (YH) Green (GH) Off White (OWSG) Semi Gloss Finish White (WSG) Silver (SSG) Gray (GYSG) Light Gray (LGYSG) Bronze (BZSG) Satin Aluminum (SAPSG) Due to variances in computer monitors and color printers, this page should be used for general reference only. For a sheet of physical color samples, please consult factory. GAMMALUX Lighting Systems 248 East Arrow Highway, San Dimas, CA 91773 Tel 909.599.9669 800.356.3275 Fax 909.599.5288 E-mail: info@gammalux.com Gammalux products comply with ARRA Buy American requirements. 5