Huawei Liquid Cooling Solution

Realize Your Potential
Huawei Liquid Cooling Solution
Huawei Liquid
Cooling Solution
D
ata center IT equipment
•
In recent years, data centers have been increasingly developed
into the ones featuring high speed, high density, and large power
consumption. The power consumption of a single cabinet can be
as high as tens of kilowatts, exerting critical air cooling capacity
and efficiency challenges to the data centers. Technologies such as
precision air supply and thermal management system (TMS) can no
longer meet heat dissipation requirements of equipment with large
power capacity.
today is predominantly
air cooled. However, with
ra c k h e a t l o a d s s t e a d i l y
climbing, the ability for many
data centers to deliver either
adequate airflow rates or
•
sufficient chilled air is now
…… This situation is creating
a need for implementing
liquid cooling solutions.
Huawei liquid cooling solution is a board-level liquid cooling solution
for high-density systems. The solution is green, energy-saving, highly
reliable, highly integrated, and easy to maintain.
——ASHRAE, 2013
Rack power - watts
Challenges of energy conservation and emission reduction
The energy consumed by traditional air cooling equipment accounts
for more than 40% of the total power consumption in a data center.
High-density scenarios such as high performance computing have
high requirements for energy conservation, emission reduction, and
total cost of ownership (TCO) decrease. The liquid cooling technology,
which outperforms in high efficiency and energy conservation, has
gradually been applied to high-density IT equipment rooms.
being stretched to the limit.
50000
Challenges and trends of high-density computing
Typical Compressor-based Cooling
Rack with 42*1U Server power trend
45000
40000
35000
IT
30000
Chiller
25000
Other Cooling
20000
Electrical
15000
Other
10000
5000
2010
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
Year of Product Announcement
Datacom Equipment Power Trends and Cooling Applications --ASHRAE
-Lawrence Berkeley National Laboratory
02
Huawei Liquid Cooling Solution
High energy efficiency
Heat dissipation
capacity
Max. 45 KW/cabinet
Energy
conservation
efficiency
Liquid cooling for more than 90% components, more than 80% energy saved
than a traditional air cooling system
PUE
Less than 1.2
High reliability
Redundancy design
Redundancy for power supply systems, sensors, fans, and LCSs
Smart monitoring
Leakage detection, auto temperature and pressure detection, auto flow control
Disaster recovery
capability
Pressure stabilizing design, automatic exhaust design, anti-condensation, leakage
detection, anti-corrosion through liquid cooling process
High integration
Integrated delivery
Three E9000s with liquid cooling systems (LCSs) in each cabinet, integration of
computing and liquid line control systems
Number of nodes
supported
96x 2P nodes, best density in the industry
Easy maintenance
Deployment,
expansion
Flexible to deploy and expand depending on equipment room conditions
Liquid-cooled
blade
Pluggable for maintenance
LCS
Online maintenance
Liquid-cooled port
Quick plugging, leakage-free maintenance
Memory
Liquid cooling, on-site flexible expansion, pluggable for maintenance
Liquid line system
Auto air exhaust, auto water makeup
Filter
Online replacement and maintenance
03
Technical Specifications of Huawei
Liquid Cooling Solution
Huawei liquid cooling system provides the scalable initial
configuration, which includes one 42 U cabinet, three E9000 blade
servers, and two LCSs, ands support up to 96 nodes.
Server
E9000 blade server
Networking
GE、10GE、FC、IB、FCoE
Cabinet power
45KW (Power supply in N + 1 backup)
27KW (Power supply in N + N backup)
Management
eSight, cluster management software
Common
configuration
Three E9000s in each cabinet
Up to 96x 2P nodes
Weight
1200kg
Dimensions
(H x W x D)
2000 mm x 800 mm x 1200 mm
Cooling
Air + liquid, warm water cooling, up to
50ºC water supply for blades
Noise
(acoustic power)
< 72 dBA
04
Huawei Liquid Cooling Solution
Technical Specifications of Liquid-Cooled Blades
Note type
CH121
CH140
Power
450W
850W
CPU
2P
(max. 165 W/P)
4P
(max. 165 W/P)
Memory quantity
24
16
Networking
GE、10GE、FC、FCoE、IB
Storage
2x 2.5-inch SAS/SATA/SSD
Dimensions (H x W x D)
60.46 mm x 215 mm x 525 mm
Management
eSight
Cooling
Air + liquid, liquid cooling for more than 90% components
Water supply
Water supply from the panel, quick onsite plugging and maintenance
OS
Windows,Redhat,SUSE,Citrix,Vmware
Liquid-cooled blades
CH121
05
CH140
Technical Specifications of Liquid Cooling System (LCS)
Heat dissipation capacity
45KW
Power
<1.5KW
Power supply
220 V AC input
Management
Independent monitoring, RS485 or FE
Common configuration
Two LCSs/cabinet, 1+1 backup
Independent LCS cabinet also supported
Weight
30kg
Dimensions (H x W x D)
260 mm x 220 mm x 750 mm
Highly integrated LCS
06
Copyright © Huawei Technologies Co., Ltd. 2014. All rights reserved.
No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei
Technologies Co., Ltd.
Trademark Notice
, HUAWEI, and
are trademarks or registered trademarks of Huawei Technologies Co., Ltd.
Other trademarks, product, service and company names mentioned are the property of their respective owners.
General Disclaimer
The information in this document may contain predictive statements including,
without limitation, statements regarding the future financial and operating results,
future product portfolio, new technology, etc. There are a number of factors that
could cause actual results and developments to differ materially from those
expressed or implied in the predictive statements. Therefore, such information is
provided for reference purpose only and constitutes neither an offer nor an
acceptance. Huawei may change the information at any time without notice.