ASSESSMENT LIST ALS 2-8 - Energy Networks Association

PRODUCED BY THE OPERATIONS DIRECTORATE OF THE ENERGY NETWORKS ASSOCIATION
ASSESSMENT LIST
ALS 2-8
Issue 8 July 2016
SWITCHGEAR
www.energynetworks.org
© 2016 Energy Networks Association
All rights reserved. No part of this publication may be reproduced, stored
in a retrieval system or transmitted in any form or by any means,
electronic, mechanical, photocopying, recording or otherwise, without the
prior written consent of Energy Networks Association. Specific enquiries
concerning this document should be addressed to:
Operations Directorate
Energy Networks Association
6th Floor, Dean Bradley House
52 Horseferry Rd
London
SW1P 2AF
This document has been prepared for use by members of the Energy
Networks Association to take account of the conditions which apply to
them. Advice should be taken from an appropriately qualified engineer on
the suitability of this document for any other purpose.
Assessment list – Switchgear
ALS 2-8 issue 8
July 2016
FOREWORD
This document contains listings of switchgear assessed by the Energy Networks
Association for use on the UK distribution and transmission networks.
Inclusion in this list only indicates the existence of a Notice of Conformity
indicating that the product has been assessed against the requirements of ENA
Technical Specifications 41-36, 41-37 and 37-2 by the ENA Switchgear
Assessment Panel. Non-compliances are not listed and the individual notice of
conformity should be consulted before any approval for use is given.
REFERENCES
ENA TS 41-36
Distribution switchgear for service up to 36kV (cable and
overhead conductor connected)
ENA TS 41-37
Switchgear for use on 66kV to 132kV distribution
systems
ENA TS 37-2
Substation cable distribution boards
DEFINITIONS
Approval Notice
An Electricity Association legacy document. These
notices are retained for information only and are not
maintained. Any information contained within these
notices needs to be reviewed and verified that it is still
current.
Notice of Conformity
An Energy Networks Association document which
details the compliance of equipment for use on UK
Transmission and Distribution Networks, with the
relevant ENA specification. An NOC is intended to assist
ENA member companies in meeting UK legislation on
the selection of electrical plant and products, by ensuring
that such equipment meets pre-determined functional
and operational criteria.
Assessment list – Switchgear
ALS 2-8 issue 8
July 2016
NOTICES OF CONFORMITY
NOTICE OF CONFORMITY LISTING
Assessment
Type
NOC
Number
Issue
Issue Date
1002
2
Jan-04
May-14
In Use
Siemens
3AP1-FG
145kV
NOC
1003
4
Apr-13
Apr-16
In Use
ABB
ELK-0 Mk.4
145kV
NOC
NOC
NOC
NOC
NOC
NOC
NOC
NOC
NOC
NOC
NOC
NOC
NOC
NOC
NOC
NOC
NOC
NOC
NOC
NOC
NOC
NOC
NOC
NOC
NOC
NOC
NOC
1004
1007
1009
1010
1011
1012
1022
1023
1024
1025
1026
1027
1029
1032
1033
1034
1036
1038
1039
1040
1041
1042
1043
1044
1045
1047
1049
2.1
2
2
1.1
1.1
1.1
1
1
3
2
2
2.1
3.1
6
4
2
1
2
2
2
2
2.1
2.1
1.1
1.1
1
1
Sep-13
Jan-14
Sep-13
Sep-13
Sep-13
Sep-13
Oct-02
Oct-02
Oct-11
May-07
Oct-14
Sep-14
Jul-16
Aug-15
Sep-15
Jun-14
Jul-05
Sep-13
Sep-13
Dec-05
Jun-07
Mar-08
Mar-08
Feb-06
Feb-06
Dec-09
Sep-06
Sep-16
Jan-17
Sep-16
Sep-16
Sep-16
Sep-16
Feb-14
Feb-14
Oct-14
Oct-08
Oct-17
Sep-17
Oct-12
Aug-18
Sep-18
Jun-17
May-15
Sep-16
Sep-16
Mar-16
Nov-15
Nov-16
Nov-16
Nov-16
Nov-16
Dec-12
Jan-13
In Use
In Use
In Use
In Use
In Use
In Use
In Use
In Use
In Use
In Use
In Use
In Use
In Use
In Use
In Use
In Use
In Use
In Use
In Use
In Use
In Use
In Use
In Use
In Use
In Use
In Use
In Use
Alstom Grid
Schneider Electric
Acrastyle
Morris Line Engineering
Morris Line Engineering
Morris Line Engineering
Ormazabal
Ormazabal
Hawker Siddeley Switchgear
Wieland
Hawker Siddeley Switchgear
ABB
Schneider Electric
Schneider Electric
Siemens
Hawker Siddeley Switchgear
ABB
ABB
ABB
Eaton Electric
W Lucy & Co Ltd
S&C Electric Canada Ltd
S&C Electric Canada Ltd
S&C Electric Canada Ltd
S&C Electric Canada Ltd
Schneider Electric
Schneider Electric
GL312
RN2-c
DB
ML
ML
ML
CML
CMP-V
Eclipse
WKC1-2.5
GVR
ZX1.2
VOX
Genie Evo
NXPlus
Horizon
PASS M0
IMB 72.5
IMB 145
Xiria r2.8
SABRE VRN2A
2010-145 kV
2020-145 kV
2010-72.5 kV
2020-72.5 kV
CBGS-0
WS 2000A
145kV
12kV
145kV
12kV
24kV
36kV
36kV
36kV
12kV
LV
15/27kV
36kV
36kV
12kV
36kV
36kV
145kV
72.5kV
145kV
12kV
12kV
145kV
145kV
72.5kV
72.5kV
NOC
1050
1.1
Mar-14
Apr-17
In Use
Mitsubishi Electric Europe BV
120 SFMT-40E
145kV
NOC
1051
1
May-07
Nov-15
In Use
W Lucy & Co Ltd
Sabre VRN6A
12kV
NOC
1053
2.1
Sep-14
Aug-17
In Use
Schneider Electric
LV Panel
LV
NOC
1054
3
Jul-14
Jul-17
In Use
Schneider Electric
LV Panel
LV
NOC
1055
2.1
Sep-14
Aug-17
In Use
Schneider Electric
LV Panel
LV
NOC
1056
3
Jul-14
Jul-17
In Use
Schneider Electric
LV Panel
LV
NOC
1057
2.1
Sep-14
Aug-17
In Use
Schneider Electric
LV Panel
LV
NOC
1058
3
Jul-14
Jul-17
In Use
Schneider Electric
LV Panel
LV
NOC
NOC
1060
1061
1.1
2.1
Sep-13
Sep-13
Sep-16
Sep-16
In Use
In Use
Arteche
Arteche
CA-145
KA-145
145kV
145kV
NOC
1062
3
Oct-13
Oct-16
In Use
Mitsubishi Electric Europe BV
GMKD-GIS
145kV
NOC
1063
1.1
Mar-16
Mar-19
In Use
Arteche
DDB 145kV CVT
145kV
Correct as of:12/07/2016:
Review Date Status
Manufacturer:
Equipment Type Ref:
Voltage
36kV
Equipment
Circuit Breaker (Live Tank)
145kV 40kA 2,500A indoor GIS type ELK-04/520 with SF6
Auto-Puffer Circuit Breaker
ELK-CB0 circuit breaker, ELK-DE0 disconnector and earthing
switch, ELK-ES0 fast acting earthing switch
Circuit Breaker(Live Tank)
Ring Main Unit 21kA version
Disconnector
Outdoor 12kV 630A type ML. Air Break Switch Disconnector
Outdoor 24kV 630A type ML. Air Break Switch Disconnector
Outdoor 36kV 630A type ML. Air Break Switch Disconnector
SF6 Switch Disconnector
Circuit Breaker (Fixed Pattern)
Circuit Breaker (Fixed Pattern)
IDC Terminals - Din Rail Mounted & Hybrid DIN Mounted rails
outdoor pole mounting auto-recloser
Circuit Breaker (Fixed Pattern)
Circuit Breaker(Dead Tank)
Circuit Breaker (Fixed Pattern)
Circuit Breaker (Fixed Pattern)
Circuit Breaker (Dead Tank)
Circuit Breaker(GIS)
Current Transformer
Current Transformer
Ring Main Unit Indoor
Ring Main Unit
Outdoor Circuit Switcher
Outdoor Circuit Switcher
Outdoor Circuit Switcher
Outdoor Circuit Switcher
Circuit Breaker (Fixed Pattern) & Switch Disconnector
Indoor SF6 insulated vacuum circuit breaker
145kv 40kA 3150A Outdoor Dead tank SF6 Gas Insulated
Circuit breaker
630A Ring Main Unit
415V 18kA 800A Outdoor substation distribution board, 4
outgoing fuse ways. Type SA8C Mk II (SAIF)
415V 18kA Outdoor substation distribution board, 4 outgoing
fuse ways. Type SH8C Mk II (Shielded)
415V 35.5ka 1600A Outdoor substation distribution board. 4,
5 & 7 outgoing fuse ways. Type SA16C Mk II (SAIF)
415V 35.5kA 1600A Outdoor substation distribution board
4, 5 & 7 outgoing fuse ways. Type SH16C Mk II (Shielded)
415V 50kA 2500A Outdoor substation distribution board. 7
outgoing fuse ways. Type SA25C Mk II (SAIF)
415V 50kA 2500A Outdoor substation distribution board, 7
outgoing fuse ways. Type SH25C Mk II (Shielded).
Current Transformer
Combined metering transformer
145kV 2500A and 3150A 40kA Outdoor SF6 Gas Insulated
Switchgear Type GMKD-GIS
145kV Outdoor Capacitor voltage transformer
Page 1 of 3
NOTICE OF CONFORMITY LISTING
Assessment
Type
Number
Issue
Issue Date
NOC
1067
2
Jul-14
Jul-17
In Use
Alstom Grid
SC-3 range
145kV
NOC
NOC
NOC
1068
1069
1070
2
2
3
Jul-14
Jul-14
Jul-14
Jul-17
Jul-17
Jul-17
In Use
In Use
In Use
Alstom Grid
Alstom Grid
Alstom Grid
SC-3 range
SC-3 range
SC-3 range
145kV
145kV
145kV
NOC
1071
2
Jul-14
Jul-17
In Use
Alstom Grid
SC-3 range
145kV
NOC
1072
2
Jul-14
Jul-17
In Use
Alstom Grid
SC-3 range
145kV
NOC
1073
1.1
Feb-14
Feb-17
In Use
Hapam
Disconnector Type
SSB111-145
145kV
NOC
1074
2
Jun-16
Jun-19
In Use
Ormazabal
CPG-0
36kV
NOC
NOC
1075
1076
1
3
Sep-13
Jan-14
Sep-16
Jan-17
In Use
In Use
Schneider Electric
ABB
WS-GHA
Unigear 500R
36kV
12kV
NOC
1077
1.1
Jan-16
Jan-22
In Use
ABB
LTB145 Motor Drive
145kV
NOC
1078
2
Apr-14
Mar-17
In Use
Efacec
Fluofix GC-T RMU
12kV
NOC
NOC
1079
1080
1.1
2
Mar-10
Sep-13
Mar-16
Sep-16
In Use
In Use
ABB
Alstom Grid
CPB72 and CPB145
F35-4
72/145kV
145kV
NOC
1081
3
Jun-15
Jun-18
In Use
Alstom Grid
DT1-145 type F1 FK3-1
145kV
NOC
NOC
NOC
NOC
NOC
NOC
NOC
NOC
1082
1083
1085
1086
1087
1088
1089
1090
1.1
1.1
1
1
1.1
1.1
1.1
1
Feb-14
Feb-15
Jan-14
Jan-14
Feb-15
Feb-15
Oct-15
Nov-14
Jan-17
Feb-18
Jan-17
Jan-17
Feb-18
Feb-18
Oct-18
Nov-17
In Use
In Use
In Use
In Use
In Use
In Use
In Use
In Use
Siemens
W Lucy & Co Ltd
Schneider Electric
Schneider Electric
W Lucy & Co Ltd
ABB
ABB
Schneider Electric
3AP1-DTC
Acculok LV Panel
CN2, CN6, CE2 and CE6
SE6 and SN6
Acculok LV Panel
PassM00
145PMC40-B
DVCas
145kV
415V
12kV
12kV
415V
72.5kV
145kV
36kv
NOC
1091
2
Jul-15
Jul-18
In Use
Alstom Grid
HYPact
145kv
NOC
1092
2
Sep-13
Sep-16
In Use
P & B Switchgear Ltd
VOR-M
12kv
NOC
1093
2
Sep-13
Sep-16
In Use
P & B Switchgear Ltd
VOR-S
12kv
NOC
1094
1
Nov-12
Nov-15
In Use
Eaton Electric
FMX
24kV
NOC
1095
1
Jun-12
Jun-15
In Use
Siemens
8DN8-5
145kV
NOC
NOC
NOC
NOC
NOC
NOC
NOC
1096
1097
1098
1099
1100
1101
1102
1
1
1
1
Nov-13
Nov-13
Nov-13
Apr-14
Nov-16
Nov-16
Nov-16
Apr-17
1
Apr-13
Apr-16
In Use
In Use
In Use
In Use
Allocated
Allocated
In use
Coelme
Coelme
Coelme
Noja Power
Schneider Electric / Nulec
Schneider Electric / Nulec
Schneider Electric / Nulec
CBD
TCB
ES
OSM 16
U Series
N Series
RL12
132/75kV
132/75kV
132/75kV
12kV
12kV
12kV
12kV
NOC
1103
3
Jun-15
Jun-18
In use
Siemens
LMT-Sion
12kV
NOC
1104
2
Sep-15
Sep-18
In use
Siemens
8DA10
24/36kV
Correct as of:12/07/2016:
Review Date Status
Manufacturer:
Equipment Type Ref:
Voltage
Equipment
145kV STW free standing Line Earthing Switch and
Disconnector Mounted line earthing switch type (/T/H)
1250A Double break 145kV 40kA Disconnector Type S3C
2000A Double break 145kV 40kA Disconnector Type S3C
145kV STW free standing Line Earthing Switch
145kV Type STA free standing earthing switch and
Disconnector Mounted earthing switch type (/T)
2000A single break 145kV 40kA Disconnector Type SPV/T &
SPV/B/T
145kV 2500A& integral Earthing Switch, Type AM-145
Free standing Earthing switch Type ASB-145
25kA 1250A Indoor GIS SF6 Insulated vacuum circuit breaker,
Bus section and non-auto circuit breaker
Circuit Breaker (Fixed Pattern)
Circuit Breaker (Fixed Pattern)
Motor Drive Type MD300 V1.3 for LTB145D1/B Live Tank
145kv Circuit Breaker
20kA 630A/200A - Outdoor SF6 non-extensible ring main unit
with tee-off vacuum circuit breaker
Capacitive VT
145kV INDOOR GIS SF6
40kA 2500A outdoor dead tank open terminal SF6 circuit
breaker type DT1-145 F1 FK3-1
SF6 Dead tank Hybrid compact switchgear
1600 amp 3/4/5 way transformer mounted distribution cabinet
Ringmaster range. Circuit Breaker (Fixed Pattern)
Ringmaster range. Switch
800 amp 3/4/5 way transformer mounted distribution cabinet
Hybrid Outdoor, Gas Insulated Switchgear
145 kV, 40 kA, 3150 A Outdoor Dead tank SF6 Circuit Breaker
Wind main Circuit Breaker unit
Hybrid Compact Outdoor ,Gas Insulated Switchgear. 145kV,
31.5kA @ 135msec 40kA @ 40msec, 2500A
RETROFIT - 12kV 25kA 630A & 1250A Indoor vacuum circuit
breaker withdrawable truck
RETROFIT - 12kV 25kA 630A & 1250A Indoor vacuum circuit
breaker withdrawable truck
24kV, single busbar, solid and air insuated switchgear
145kV 3150A 40kA Indoor /outdoor and 145kV 2500A 40kA
Outdoor OHL connection SF6 Gas Insulated Switchgear
Centre Break Disconnector (CBD)
Double Break Disconnector (TCB)
Free-standing Earth Switch (ES).
Pole Mounted Recloser
Pole Mounted Recloser
Pole Mounted Recloser
Pole Mounted load break switch
RETROFIT - 12kV 25kA 630A & 1250A Indoor vacuum circuit
breaker withdrawable truck
24kV 40kA 2500A; 36kV 25/31.5kA 1250/2000A
Indoor Gas Insulated Vacuum Circuit Breaker
Page 2 of 3
NOTICE OF CONFORMITY LISTING
Assessment
Type
NOC
NOC
NOC
Number
Issue
Issue Date
1105
1106
1107
1
1
1
May-13
Sep-13
Mar-14
May-16
Sep-16
Mar-17
In use
In use
In use
Alstom Grid
ABB
CG Power Systems
DT1-72.5 F1 FK3-1
Safelink E RMU
Type GT01
72.5kV
12kV
145kV
NOC
1108
1
Sep-14
Sep-17
In use
Ormazabal
CGM.3
36kv
NOC
NOC
1109
1110
1
1
Jul-14
Jul-14
Jul-17
Jul-17
In Use
In Use
Trench Italia
Trench Italia
TCVT 72.5kV
TCVT 145/4 kV
72.5kV
145kV
NOC
1111
1
Nov-14
Nov-17
In Use
Mitsubishi Electric Europe BV
GMKD-1-GIS
145kV
NOC
1112
1
Jan-15
Jan-18
In Use
Hawker Siddeley Switchgear
SWR 12/25 retrofit
12kV
NOC
1113
2
Jul-16
Jul-19
In Use
Tamco
VH1F
12kV
NOC
1114
1
Feb-15
Feb-18
In Use
ABB
ZX0.2
36kV
NOC
1115
1
Sep-15
Sep-18
In Use
Alstom Grid
STA
72.5kV
NOC
1116
1
Sep-15
Sep-18
In Use
Alstom Grid
STW
72.5kV
NOC
NOC
1117
1118
1
1
Sep-15
Mar-16
Sep-18
Mar-19
In Use
In Use
Alstom Grid
ABB
S3C
SafePlus 36
72.5kV
36kV
NOC
1119
1
Apr-16
Apr-19
In Use
RPS Switchgear
LMVP Retrofit Mk1
12kV
NOC
1120
1
Apr-16
Apr-19
In Use
RPS Switchgear
LMVP Retrofit Mk2
12kV
NOC
1121
1
Apr-16
Apr-19
In Use
RPS Switchgear
LMVP Extension panel
12kV
NOC
1122
1
May-16
May-19
In Use
ABB
DCB145 D1/B
145kV
NOC
NOC
NOC
NOC
1123
1124
1125
1126
1
1
1
1
Jul-16
Jul-16
Jul-16
Jul-19
Jul-19
Jul-19
Allocated
Allocated
Allocated
Allocated
Siemens
Tamco
Schneider Electric
Noja Power
NXPlusC Wind
GV3N
Premset
OSM 15
36kv
36kv
12kv
12kV
Correct as of:12/07/2016:
Review Date Status
Manufacturer:
Equipment Type Ref:
Voltage
Equipment
72.5 kV 2500A 40kA Outdoor Dead Tank Circuit Breaker
12kV Transformer mounted RMU
Indoor GIS Bay type GT01
Switch Disconnector Type CGM.3-L
Switch-Fuse Type CGM.3-P
Non Autoreclosing Circuit Breaker Type CGM.3-V-AV
Autoreclosing Circuit Breaker Type CGM.3-V-RAV
Busbar Riser/ Earthing Switch Type CGM.3-RB
Capacitor Voltage Transformer
Capacitor Voltage Transformer
2000A and 3150A 40kA Indoor/Outdoor SF6 Gas Insulated
Switchgear
12kV 25kA 400/630A, 800A & 1250A Indoor retrofit circuit
breaker
25kA 800, 1250A & 2000A Indoor Air Insulated Fixed Vacuum
Circuit Breaker
31.5kA 1250A, 2000A & 2500A Indoor GIS SF6 Insulated
Vacuum Circuit Breaker
72.5 kV STW free standing Earthing Switch and Disconnector
Mounted earthing switch type (/T)
72.5 kV STW free standing Line Earthing Switch and
Disconnector Mounted line earthing switch type (/T/H
2000A Double break 72.5 kV 40kA Disconnector Type S3C
20kA 630A Indoor SF6 insulated vacuum circuit breaker
LMVP Switchgear & Retrofit Circuit Breakers for type ‘LM’ Mk
1 switchgear
LMVP Switchgear & Retrofit Circuit Breakers for type ‘LM’ Mk
2 switchgear
LMVP Extension Panel, with separate CT chamber
145 kV 40kA, 3150A Indoor/Outdoor Disconnecting circuit
breaker SF6 insulated type DCB145 D1/B with associated
earthing switch type NVA 145
Circuit breaker
GIS Circuit Breaker
Ring mian unit
OSM15 12.5/800-311 auto recloser
Page 3 of 3
Assessment list – Switchgear
ALS 2-8 issue 8
July 2016
APPROVAL NOTICES
Please note: these notices are no longer maintained and users should review
any information contained within them to ensure it is still valid.
APPROVAL NOTICE LISTING
Number
Issue Date
Review Date
Status
125
125A
126
126A
127
127A
191
191A
192
192A
193
193A
194
197_iss2
198_iss2
200
201
01/08/1991
22/09/2005
01/08/1991
22/09/2005
01/08/1991
22/09/2005
01/06/1995
01/09/1998
01/06/1995
01/09/1998
01/06/1995
01/09/1998
01/06/1995
25/03/2009
25/03/2009
01/07/1995
01/07/1995
Mar-12
Mar-12
Mar-12
Mar-12
Mar-12
Mar-12
Jan-12
Jan-12
Jan-12
Jan-12
Jan-12
Jan-12
Jan-12
Jun-09
Jun-09
Jun-09
Jun-09
In Use
In Use
In Use
In Use
In Use
In Use
In Use
In Use
In Use
In Use
In Use
In Use
In Use
In Use
In Use
In Use
In Use
NI Transformers (UK) Ltd
ABB Power Ltd
NI Transformers (UK) Ltd
ABB Power Ltd
NI Transformers (UK) Ltd
ABB Power Ltd
Ruhrtal
Ruhrtal
Ruhrtal
Ruhrtal
Ruhrtal
Ruhrtal
Ruhrtal
Hawker Siddeley Power Transformers
Hawker Siddeley Power Transformers
Merlin Gerin
Merlin Gerin
TMC 3s
TMC 3s
TMC 2s
TMC 2s
TMC 1s
TMC 1s
DBF4
DBF4
HMH8025 MAN611.N
HMH8025 MAN611.N
AE.BF.260
AE.BF.260
DBF230
AE
AE
CE6
CE2
Fuse Cabinet
Fuse Cabinet
LV Equipment
LV Equipment
Fuse Cabinet
Fuse Cabinet
Disconnector
Disconnector
Mechanism
Mechanism
Earth Switch
Earth Switch
Disconnector
Tap Changer 21 Position
Tap Changer 33 Position
Circuit Breaker (Fixed Pattern)
Circuit Breaker (Fixed Pattern)
AN
228a
11/01/2006
Feb-14
In Use
Areva (AEG T & D)
WS 1250A
Circuit Breaker (Fixed Pattern)
Correct as of 12/07/2016
Manufacturer:
Equipment Type Ref:
Equipment
Assessment
Type
AN
AN
AN
AN
AN
AN
AN
AN
AN
AN
AN
AN
AN
AN
AN
AN
AN
1 of 1