1 Minimum Hardware Requirements Preparing the Chassis To avoid integration difficulties and possible board damage, your system must meet the following minimum requirement Please refer to the documentation that came with your chassis for preparatory steps. ● Memory Type: Minimum of one 4GB DDR4 1600/1866/2133/2400 MHz Observe normal ESD (Electrostatic Discharge) procedures. UDIMM/RDIMM. Place your Server Chassis and Server Board on a flat anti-static surface to perform the following integration procedures. Always touch the chassis frame first, before reaching inside to install the N60E-O Quick Start User Guide server board, make server board connections or install other components. Tools Required Thank you for buying the Giada Server Board N60E-O. The following information will help you integrate your new server board into a server chassis. 2 Fastener Identification Guide Flat-blade screwdriver Installing the I/O Shield and Chassis Screw Stand-offs I/O shield Giada, the premium brand of SHENZHEN JEHE TECHNOLOGY DEVELOPMENT CO.,LTD., is a well-established provider of server products designed for data storage, cloud computing, Phillips* screwdriver video surveillance and cloud computing applications etc., and has received great popularity Anti-static wrist strap among industrial and home users. Giada is committed to providing high performance and highly reliable server products. This user manual provides detailed information for better understanding about the product and its usage. Should you have any further questions, Chassis Back Panel Opening please don't hesitate to call our after-sales hotline or technical support hotline. Install the I/O shield Giada Server Board N60E-O Layout Diagram Website: www.giadatech.com IO Shield should be installed from inside of the chassis. The labels should be visible from the outside of the chassis. B A A Insert one side edge of B Push shield firmly into chassis opening until it clicks into place. US: West/South/North Europe: america.sales@giadatech.com sales_eu@giadatech.com TEL:+1-626566-7776 TEL:+86-755-33300723 Middle East and Africa: Asia: sales_me@giadtech.com sales_asia@giadatech.com TEL:+86-755-33300769 TEL:+886-2-87120510 East EU/RU/CIS Other Regions: sales_easteu@giadtech.com sales@giadatech.com the server board has mounting screw holes as TEL:+886-2-87120510 TEL:+886-2-87120510 indicated by A C J shield as shown. Install the chassis screw stand-offs If installing the server board inside a Server Chassis, the stand-off for the server board mounting screws come with chassis must be installed first. G A … Z . Please install the chassis stand-offs to the chassis locations indicated by same marks. Z X Warning 3 Install the Server Board 4 B. Attach the Server Board Install DIMM Memory Modules DDR4 DIMM Memory Identification: Use screws to attach the board to the chassis at the 6 locations indicated by the solid blue arrows in the figure. IMPORTANT NOTE: Please see your chassis documentation for preparatory steps prior to server board installation. CAUTION: Observe normal ESD (ElectroStatic Discharge) A. Insert the Server Board Read all caution and safety statements in this document before performing any of the instructions. Memory Type: Minimum of one procedures to avoid possible damage to system components. 4GB DDR4 1600/1866/2133/ Place the board into the chassis, making sure that back panel I/O openings and chassis standoffs align correctly. Insert the front of the board first, then slide the board back so the I/O connectors fit through the I/O openings at the rear of the chassis. This server board supports up to 4 DDR4 1600/1866/2133 Warning 2400 MHz UDIMM/RDIMM. /2400 MHz UDIMM/RDIMM. DIMM notch and socket bump must align as shown. The schematic diagram of server chassis Installation and service of this product should only be performed by qualified service personnel to avoid risk of injury from electrical shock or energy hazard. Memory Configurations and Population Order: Fastener I/O Openings DDR4 Caution Observe normal ESD [Electrostatic Discharge] procedures during system integration to avoid possible damage to server board and/or other components. 5 6 Make Server Board Power Connections A Attach the CPU power connector. 2/F, block A, Tsinghua Information Harbor, North Connect Hard Drives/Optical Drive to Server Board Connect SATA Data Cables to server board here. server chassis for drive installation. B SATA 5 Attach the main power connector. CPU Power Connector Detail Main Power 主电源接口示意图 Connector Detail Section, Shenzhen Hi-tech Park, Nanshan District, Shenzhen, China 7 See the documentation that came with your SHENZHEN JEHE TECHNOLOGY DEVELOPMENT CO., LTD Install Optical Drive and Hard Drive(s) CAUTION: Note the location of the A latch on each power cable connector and align it with the matching tab on each server board socket. SATA 4 SATA 3 SATA 2 SATA 1 IMPORTANT NOTE: SATA 0 Please see the documentation that came with your chassis for power supply installation information. B All SATA ports are 6Gb/s SATA ports. 8 9 Attach Front Panel Connection 10 Chassis Fan Connections Install TPM (Optional) To install the TPM module, follow these steps: System Fan Connector Detail 1. Turn off the power to the system, all drives, enclosures, and system components. Remove the power cord(s). 2. Remove the server cover. 3. Insert the TPM module connector into the connector in the board. Front Panel Connection Detail 4. Press down gently but firmly to ensure that the module is properly seated in the connectors. Note: Make CPU FAN connections Front Panel if necessary. See the documentation accompanying your chassis for specific chassis fan connection requirements. 11 12 Install Add-in Card (Optional) 13 Finishing Up Before installing your operating system, you must finish your chassis installation, make I/O connections and plug in AC power. See the documentation that came with your server chassis for add-in card installation. Operating System Drivers Installation Common Problems and Solutions With the operating system running, insert the Giada Driver DVD. If using a Network The system does not boot or show video at power-on stage. Microsoft Windows operating system, the DVD drive will autorun and allow IPMI_LAN • Check that the +12V CPU power connector is plugged in. Without this cable, you to select the appropriate drivers to install. the processors will not have any power. On other operating systems, browse the DVD folders to locate and install the driver files. Remember, all DIMMs must be: • DDR4 1600/1866/2133/2400 MHz UDIMM/RDIMM. • From the same manufacturer. USB3.0 CAUTION: See your chassis documentation for AC power and grounding requirements. • Installed beginning with DIMM A1. 10G SFP+ Video Making Connections to the Server Board — Quick Reference Required Connections UID_LED Reference = Make this connection Optional Connections Chassis 2: Cable Routing with Hotswap Fans, backplane(s), redundant PSU(s) UID_BTN Chassis A. CPU Power Connector B. Main Power Connector C. Front Panel Header Chassis 1: Cable Routing with Fixed Fans, Fixed HDDs, Fixed PSU JIPMB1 J Chassis 1 Chassis 2 D. Fan 0 Header E. Fan 1 Header F. Fan 2 Header G. Case Open Header H. UID_LED Header I. UID_BTN Header J. JD1 Header K. BMC_EN Header L.TPM Header M. JIPMB1 Connector N. USB 2.0 Header O. SATA Connector P. SATA DOM_PWR Connecter Q. PMBUS Connecter R. F_COM Header F_COM BMC_EN K JD1 I Make the connections with fixed fans Make the connections with hotswap fans, backplans, power supplys Make the connections when applicable NOTE:Not all optional connections are shown in this diagram. A B C D E IMPORTANT NOTE: Cables should be tied for better airflow. Use cable-ties as necessary. CPU Power Cable Server Board Main Power Cable Fixed HDD Power Cable ODD Power Cable Front Panel Cable, USB Cable F ODD Data Cable (Connect To SATA 6G Connectors On Server Board) G Fixed HDD Data Cable H System FAN 1 I System FAN 0 CPU Power Cable Server Board Main Power Cable Backplane Power Cable ODD Power Cable Front Panel Cable, USB Cable ODD Data Cable (Connect To SATA 6G Connectors On Server Board) G SGPIO H PMBus Cable A B C D E F I System FAN 0 J System FAN 1 K System FAN 2