N60E-O Quick Start User Guide

advertisement
1
Minimum Hardware Requirements
Preparing the Chassis
To avoid integration difficulties and possible board damage, your system must
meet the following minimum requirement
Please refer to the documentation that came with your chassis for preparatory steps.
● Memory Type: Minimum of one 4GB DDR4 1600/1866/2133/2400 MHz
Observe normal ESD (Electrostatic Discharge) procedures.
UDIMM/RDIMM.
Place your Server Chassis and Server Board on a flat anti-static surface to perform the following
integration procedures. Always touch the chassis frame first, before reaching inside to install the
N60E-O Quick Start User Guide
server board, make server board connections or install other components.
Tools Required
Thank you for buying the Giada Server Board N60E-O. The following information will help you
integrate your new server board into a server chassis.
2
Fastener Identification Guide
Flat-blade
screwdriver
Installing the I/O Shield and Chassis Screw Stand-offs
I/O shield
Giada, the premium brand of SHENZHEN JEHE TECHNOLOGY DEVELOPMENT CO.,LTD., is a
well-established provider of server products designed for data storage, cloud computing,
Phillips*
screwdriver
video surveillance and cloud computing applications etc., and has received great popularity
Anti-static
wrist strap
among industrial and home users. Giada is committed to providing high performance and
highly reliable server products. This user manual provides detailed information for better
understanding about the product and its usage. Should you have any further questions,
Chassis Back
Panel Opening
please don't hesitate to call our after-sales hotline or technical support hotline.
Install the I/O shield
Giada Server Board N60E-O Layout Diagram
Website: www.giadatech.com
IO Shield should be installed
from inside of the chassis.
The labels should be visible
from the outside of the chassis.
B
A
A
Insert one side edge of
B
Push shield firmly into
chassis opening until it
clicks into place.
US:
West/South/North Europe:
america.sales@giadatech.com
sales_eu@giadatech.com
TEL:+1-626566-7776
TEL:+86-755-33300723
Middle East and Africa:
Asia:
sales_me@giadtech.com
sales_asia@giadatech.com
TEL:+86-755-33300769
TEL:+886-2-87120510
East EU/RU/CIS
Other Regions:
sales_easteu@giadtech.com
sales@giadatech.com
the server board has mounting screw holes as
TEL:+886-2-87120510
TEL:+886-2-87120510
indicated by
A
C
J
shield as shown.
Install the chassis screw stand-offs
If installing the server board inside a Server
Chassis, the stand-off for the server board
mounting screws come with chassis must be
installed first.
G
A
…
Z
.
Please install the chassis stand-offs to the chassis
locations indicated by same marks.
Z
X
Warning
3
Install the Server Board
4
B. Attach the Server Board
Install DIMM Memory Modules
DDR4 DIMM Memory Identification:
Use screws to attach the board to the chassis at the 6 locations
indicated by the solid blue arrows in the figure.
IMPORTANT NOTE: Please see your chassis documentation for
preparatory steps prior to server board installation.
CAUTION: Observe normal ESD (ElectroStatic Discharge)
A. Insert the Server Board
Read all caution and safety
statements in this document
before performing any of the
instructions.
Memory Type: Minimum of one
procedures to avoid possible damage to system components.
4GB DDR4 1600/1866/2133/
Place the board into the chassis, making sure that back panel I/O openings
and chassis standoffs align correctly.
Insert the front of the board first, then slide the board back so the I/O
connectors fit through the I/O openings at the rear of the chassis.
This server board supports up to 4 DDR4 1600/1866/2133
Warning
2400 MHz UDIMM/RDIMM.
/2400 MHz UDIMM/RDIMM.
DIMM notch
and socket
bump must
align as
shown.
The schematic
diagram of server
chassis
Installation and service of this
product should only be
performed by qualified
service personnel to avoid
risk of injury from electrical
shock or energy hazard.
Memory Configurations and Population Order:
Fastener
I/O Openings
DDR4
Caution
Observe normal ESD
[Electrostatic Discharge]
procedures during system
integration to avoid possible
damage to server board
and/or other components.
5
6
Make Server Board Power Connections
A
Attach the CPU power connector.
2/F, block A, Tsinghua Information Harbor, North
Connect Hard Drives/Optical Drive to Server Board
Connect SATA Data Cables to server board here.
server chassis for drive installation.
B
SATA 5
Attach the main power connector.
CPU Power
Connector Detail
Main Power
主电源接口示意图
Connector Detail
Section, Shenzhen Hi-tech Park, Nanshan District,
Shenzhen, China
7
See the documentation that came with your
SHENZHEN JEHE TECHNOLOGY DEVELOPMENT CO.,
LTD
Install Optical
Drive and
Hard Drive(s)
CAUTION: Note the location of the
A
latch on each power cable connector
and align it with the matching tab
on each server board socket.
SATA 4
SATA 3
SATA 2
SATA 1
IMPORTANT NOTE:
SATA 0
Please see the documentation
that came with your chassis for
power supply installation information.
B
All SATA ports are 6Gb/s SATA ports.
8
9
Attach Front Panel Connection
10
Chassis Fan Connections
Install TPM (Optional)
To install the TPM module, follow these steps:
System Fan
Connector
Detail
1. Turn off the power to the system, all drives, enclosures, and system components. Remove
the power cord(s).
2. Remove the server cover.
3. Insert the TPM module connector into the connector in the board.
Front Panel
Connection
Detail
4. Press down gently but firmly to ensure that the module is properly seated in the connectors.
Note: Make CPU
FAN connections
Front Panel
if necessary.
See the documentation accompanying your chassis for specific chassis fan
connection requirements.
11
12
Install Add-in
Card (Optional)
13
Finishing Up
Before installing your operating
system, you must finish your
chassis installation, make I/O
connections and plug in
AC power.
See the documentation that came
with your server chassis for add-in
card installation.
Operating System Drivers Installation
Common Problems and Solutions
With the operating system running, insert the Giada Driver DVD. If using a
Network
The system does not boot or show video at power-on stage.
Microsoft Windows operating system, the DVD drive will autorun and allow
IPMI_LAN
• Check that the +12V CPU power connector is plugged in. Without this cable,
you to select the appropriate drivers to install.
the processors will not have any power.
On other operating systems, browse the DVD folders to locate and install
the driver files.
Remember, all DIMMs must be:
• DDR4 1600/1866/2133/2400 MHz UDIMM/RDIMM.
• From the same manufacturer.
USB3.0
CAUTION: See your chassis
documentation for AC power
and grounding requirements.
• Installed beginning with DIMM A1.
10G SFP+
Video
Making Connections to the Server Board — Quick Reference
Required Connections
UID_LED
Reference
= Make this connection
Optional Connections
Chassis 2: Cable Routing with Hotswap Fans, backplane(s), redundant PSU(s)
UID_BTN
Chassis
A. CPU Power Connector
B. Main Power Connector
C. Front Panel Header
Chassis 1: Cable Routing with Fixed Fans, Fixed HDDs, Fixed PSU
JIPMB1
J
Chassis 1 Chassis 2
D. Fan 0 Header
E. Fan 1 Header
F. Fan 2 Header
G. Case Open Header
H. UID_LED Header
I. UID_BTN Header
J. JD1 Header
K. BMC_EN Header
L.TPM Header
M. JIPMB1 Connector
N. USB 2.0 Header
O. SATA Connector
P. SATA DOM_PWR Connecter
Q. PMBUS Connecter
R. F_COM Header
F_COM
BMC_EN
K
JD1
I
Make the connections with fixed fans
Make the connections with hotswap fans, backplans, power supplys
Make the connections when applicable
NOTE:Not all optional connections are shown in this diagram.
A
B
C
D
E
IMPORTANT NOTE:
Cables should be
tied for better airflow.
Use cable-ties as necessary.
CPU Power Cable
Server Board Main Power Cable
Fixed HDD Power Cable
ODD Power Cable
Front Panel Cable, USB Cable
F ODD Data Cable (Connect To
SATA 6G Connectors On Server Board)
G Fixed HDD Data Cable
H System FAN 1
I System FAN 0
CPU Power Cable
Server Board Main Power Cable
Backplane Power Cable
ODD Power Cable
Front Panel Cable, USB Cable
ODD Data Cable (Connect To SATA 6G
Connectors On Server Board)
G SGPIO
H PMBus Cable
A
B
C
D
E
F
I System FAN 0
J System FAN 1
K System FAN 2
Download