F5 182 | arabesque 5 integrations w w w.al i ghts .c om a·light F5 | arabesque 5 project type quantity Optics a·cirrus™ regressed | t-bar WISP™ | t-bar a·cirrus™ | trim flange HTLO™ | regressed gyp Lengths: Mounting: non-standard nominal individual lengths: 5', 6', 7', 9', 10', 11' gyp trimless nominal rows longer than 24' 1/2" trim exact lengths to the nearest 100th of an inch t-bar recessed Additional Integrations Selections + Optons: custom mounting custom finish precise lengths Design-Assist: shadow molding perimeter in-house design-assist team manages your unique project hidden grid Cross Sections Multiple configurations available sampling shown T5 T5 T5 8” lens 15/16" t-bar "X" lens 9/16" t-bar "T" lens 9/16" slot t-bar "N" LED 5” 7-3/4” aper ture T5 T8 T5 lens shadowmold + gyp flange "Z" (paint over flange) (paint over flange) Available Light Platforms LED integrations T5 T8 lens 1" regressed gyp flange "RG" lens 1/2" trim flange "XP" Available Mounting recessed controls friendly w w w.al i ghts .c om Version | March 2014 183 F5 | arabesque 5 integrations Linear Dimensions: Standard lengths available are located on the 'elements' spec sheet. All other lengths should be specified as follows... Shadowmold. Dual-flanged housing creates a 5/8" shadowed gap along wall/surface with choice of ceiling flange on opposite side for perimeter mounting. Shadowmold spacer is painted black. Exposed side of housing next to wall is unpainted - housing may be field-painted if necessary. Nominal Damp Location Row R___: Specify in nominal feet. Choose when nominal length is acceptable. Actual length will be shorter or longer due to metric lamp lengths. Lengths over 12' are comprised of multiple sections. Examples: a nominal 54ft row begins as F5R54; a 7ft individual as F5R7. Finish: Electrostatically applied powder coat finish. Construction: 60% recycled aluminum extruded housing. Steel endcaps with earthquake suspension cable attachment holes. Nominal Wet Location Run G___: Specify in nominal feet. Choose when nominal length is acceptable and wet location is necessary. Actual length will be shorter or longer due to metric lamp lengths. Lengths over 12' are comprised of multiple sections with minimal endcaps, joined via wet rated connectors (by others). Examples: a nominal 54ft row begins as F5G54; a 7ft individual as F5G7. Listing: UL/CUL. Damp or Wet Location. Companion Luminaires: F3 suspended/ceiling/wall. Exact Row M___: Specify overall length in inches to the nearest hundredth. Choose when exact lengths are required as determined by space constraints, etc. Submittals required. Lengths over 12' are comprised of multiple sections. Examples: an exact 54ft row begins as F5M648.00; a 7ft individual as F5M84.00. Patterns are not available due to large housing size. Lamping: LED. 5yr warranty. >60,000hr LED life. Tested to LM-79 and LM-80. See wattage/lumen table for specifications per foot. All specifications are subject to change. LED T5/T5HO. Single or dual lamps in cross section or staggered single lamping. Low-profile electronic, high power factor, program start, sound rating A, inherent thermal protection, UL listed Class P, <10% THD. Dimming: T5 specify manufacturer/model. T8. Single or dual lamps in cross section or staggered single lamping. Low-profile electronic, choose low, standard or high power factor, instant start, sound rating A, inherent thermal protection, UL listed T8 Class P, <10% THD. Specify if program start or custom ballast factor required. Dimming: specify manufacturer/model. Mounting: Flush gyp/hard ceiling or wall. “Flangeless” appearance for gyp or other hard ceiling/wall. Flange is not visible and is not factory-painted. Raw aluminum flange must be attached to blocking (by others), mudded over and painted by ceiling contractor for flangeless appearance. Regressed flush gyp/hard ceiling or wall. Same as above except flange raises lens up into ceiling. "RG" is 1" regressed resulting in a 4.5” height. Interior 1" regressed portion is exposed raw aluminum and visible on both sides unless finish is chosen. Contractor should apply ceiling paint if finish is not chosen. Trim Flange. 1/2” visible powdercoated flange. Use for any gyp or hard ceiling/ wall that requires a minimal flange covering the ceiling cut-out edge. Choose finish color for trim flange. T-Bar. Standard T-Bar/Grid Ceiling: 9/16” or 15/16” standard T-Bar or 9/16” slot ceiling. Raw aluminum flange sits on T-Bar, is not visible and is not painted. Legend: 1. Emergency ballast not applicable on lengths 3ft or less. 8. “S” optics recommended for use with LED. 2. Multi-circuiting: submit multi-circuiting requirements during submittal process. 9. 3. Standard on/off occupancy sensor: Wattstopper FS-205 with minimal 1” diameter. Staggered lamping not available on lengths less than 8ft. 8ft length uses 3-3ft lamps. 12ft uses 2-3ft and 2-4ft lamps. 4. Standard occupancy sensor with photocell: Wattstopper FS-205 wired for daylight harvesting. Requires 0-10V dimming ballast. 5. Lens is required for use in wet or natatorium locations. 6. Not available with staggered or dual fluorescent lamping. Only 1 board in cross section is used for LED. 7. Staggered lamping not recommended with HTLO™. 184 w w w.al i ghts .c om a·light | arabesque 5 project Series: F5 per foot LS LH symmetric 2 boards in cross watts/ft lumens/ft 10 1200 20 2400 a·cirrus™ lens HTLO™ lens WISP™ lens a·wash™ kicker + a·cirrus™ a·wash™ kicker + HTLO™ a·wash™ kicker + WISP™ Row or Pattern Type: for standard lengths available: see 'elements' specification sheet damp location nominal length row R___ wet location nominal length run G___ exact length row M___ Length: _____ nominal length "R" or "G" (specify in feet) exact length "M" (specify in inches to nearest 100th) _____ Lamping: LED standard output 8 LS LED high output 8 LH T5 (1) S T5HO (1) H T5 (2) D T5HO (2) O T5 staggered 9 2 T5HO staggered 9 4 T8 (1) low output T8L T8 (1) standard output T8S T8 (1) high output T8H T8 (2) low output T8LD T8 (2) standard output T8SD T8 (2) high output T8HD T8 staggered low output 9 T8LS T8 staggered standard output 9 T8SS T8 staggered high output 9 T8HS LED Temp (if applicable): 3000k 30 3500k 35 4000k 40 Voltage: universal 120V - 277V U 120V 1 277V 2 347V 3 LED type flush gyp/hard lid - no finish 1" regressed gyp - optional finish trim flange - choose finish t-bar 9/16” - no finish t-bar 15/16” - no finish t-bar 9/16” slot - no finish shadowmold + flush gyp - no finish shadowmold + 9/16" t-bar - no finish shadowmold + 15/16" t-bar - no finish custom a∙lightanium™ satin white satin black textured eggshell white other - specify RAL# no finish (t-bar or gyp/no MR16) custom dimming - specify manufacturer, model/series and voltage emergency - specify model/series or lumens external fusing multi-circuit new york city code chicago plenum code occupancy sensor photocell/daylight sensor natatorium application wet label quantity Optics: A 7 H 8 S 6 KA 6 KH 6 KS Mounting: G RG XP T X N Z Y U C Finish: T W B E O C Options: D 1 E F 2 M N C 3 O 4 P 5 K 5 Q recessed F5 asymmetric 1 board in cross watts/ft lumens/ft 5 600 10 1200 Lumens at board at 4000k. Consult IES files online for delivered lumens. Specifications subject to change. integrations w w w.al i ghts .c om Version | March 2014 185