accoLED 5 integrations accoLED 5 project type quantity Optics Delivered Lumens Pending Test Results. Lengths: precise lengths non-standard nominal individual lengths: 2’, 3’, 5', 6', 7', 9', 10', 11', etc. shadow molding perimeter nominal rows longer than 24' hidden grid exact lengths to the nearest 100th of an inch patterns ╔╔ c ustom angles Optons: recessed Additional Integrations Selections custom finish ╔╔ precise lengths MRI configuration ╔╔ wall-to-wall specification Design-Assist: ╔╔ L's, U's, squares and rectangles in-house design-assist team manages your unique project ╔╔ tig-welded corners, sanded smooth to eliminate light leaks Mounting: ╔╔ f ully lit corners with mitered lenses gyp trimless ╔╔ staggered trays eliminate socket shadows 1/2" trim ╔╔ seamless transitions between sections and various mounting types t-bar ╔╔ LED recommended for patterns, T5 staggered allowed, T8 n/a + custom mounting Cross Sections Multiple configurations available sampling shown 3.375” 2.25” Available Light Platforms LED integrations Available Mounting recessed controls friendly w w w.al i ghts .c om 2 accoLED 5 integrations Linear Dimensions: Standard lengths available are located on the ‘elements’ spec sheet. All other lengths should be specified as follows... Nominal Damp Location Row R___: Specify in nominal feet. Choose when nominal length is acceptable. Actual length will be shorter or longer due to metric lamp lengths. Lengths over 12’ are comprised of multiple sections. Examples: a nominal 54ft row begins as ACL5R54; a 7ft individual as ACL5R7. Exact Row M___: Specify overall length in inches to the nearest hundredth. Choose when exact lengths are required as determined by space constraints, etc. Submittals required. Lengths over 12’ are comprised of multiple sections. Examples: an exact 54ft row begins as ACL5M648.00; a 7ft individual as ACL5M84.00. Pattern Dimensions: Each pattern contains a precision-formed optical platform engineered for maximum light output and even distribution. Pattern Specify overall length of each section in inches to the nearest hundredth. Choose when multiple angles are necessary. Submittals required: contact our design-assist team and submit architectural drawings with precise lengths. 90° angles are assumed unless otherwise specified. LED: LED Shadowmold. Dual-flanged housing creates a 5/8" shadowed gap along wall/surface with choice of ceiling flange on opposite side for perimeter mounting. Shadowmold spacer is painted black. Exposed side of housing next to wall is unpainted - housing may be field-painted if necessary. "RG5": is intended only for perimeter mounting in gyp ceiling. The 5" regressed gyp flange on one side, with shadowmolding on the opposite side, results in a 8.5” overall height. Interior 5" regressed portion is exposed raw aluminum and visible unless finish is chosen. Contractor should apply ceiling paint if finish is not chosen. Finish: Electrostatically applied powder coat finish. Construction: 60% recycled aluminum extruded housing. Steel endcaps with earthquake suspension cable attachment holes. Optional MRI housing configuration is specially built with all non-ferrous materials. Listing: UL/CUL. Damp or Wet Location. Family Luminaires: ACL1 suspended, ACL2 suspended/wall, ACL3 suspended/ceiling/wall, ACL4 wall. 5yr warranty. >60,000hr LED life. Tested to LM-79 and LM-80. See wattage/lumen table for specifications per foot. All specifications are subject to change. Companion Luminaires: D1 suspended, D2 suspended/wall, D3 suspended/ceiling/wall, D4 wall, D5 recessed, D6 recessed. Mounting: Flush gyp/hard ceiling or wall. “Flangeless” appearance for gyp or other hard ceiling/wall. Flange is not visible and is not factory-painted. Raw aluminum flange must be attached to blocking (by others), mudded over and painted by ceiling contractor for flangeless appearance. Regressed flush gyp/hard ceiling or wall. Same as above except flange raises lens up into ceiling. "RG" is 1" regressed resulting in a 4.5” height. Interior 1" regressed portion is exposed raw aluminum and visible unless finish is chosen. Contractor should apply ceiling paint if finish is not chosen. Trim Flange. 1/2” visible powdercoated flange. Use for any gyp or hard ceiling/wall that requires a minimal flange covering the ceiling cut-out edge. Choose finish color for trim flange. T-Bar. Standard T-Bar/Grid Ceiling: 9/16” or 15/16” standard T-Bar or 9/16” slot ceiling. Raw aluminum flange sits on T-Bar, is not visible and is not painted. 4” Armstrong Techzone™ / USG Logix™ or other 4” Utility Systems: Suitable for use in 4” on-center standard or slot T-Bar systems. Raw aluminum flange sits on T-Bar, is not visible and is not painted. The N4 option requires that the housing sit on top of the slot, creating a slightly recessed fixture. The T4 fixture will sit flush to ceiling. Concealed Grid for Decoustic Ceilencio®: 2-3/4” panel/grid regress. Raw aluminum flange sits on T-Bar, is not visible and is not painted. Legend: 3 1. Emergency ballast not applicable on lengths 3ft or less. 2. Multi-circuiting: submit multi-circuiting requirements during submittal process. 3. Standard on/off occupancy sensor: Wattstopper FS-205 with minimal 1” diameter. 4. Standard occupancy sensor with photocell: Wattstopper FS-205 wired for daylight harvesting. Requires 0-10V dimming ballast. 5. The N4 mounting requires the housing to sit on top of the slot T-Bar creating a slight regress and will not sit flush to ceiling tile. w w w.al i ghts .c om a·light project Series: ACL 5 LCW LWW LW LC UW UC UWW UWC RW RC P dimming - specify manufacturer, model/series and voltage emergency - specify model/series or lumens external fusing multi-circuit new york city code chicago plenum code occupancy sensor photocell/daylight sensor natatorium application wet label MRI housing configuration Pattern lengths: (specify in inches to nearest 100th) 2 leg patterns "L's" 1st length = short leg x 2nd length = long leg example: ACL3LCW103.65 x 134.80 3 leg patterns "U's" 1st length x center length x last length ACL3P103.65 x 134.80 x 103.65 > 3 legs of different lengths enter lengths in order of placement ACL3P103.65 x 134.80 x 103.65 x 35.00 quantity a∙lightanium™ satin white satin black other - specify RAL# no finish (t-bar or gyp) custom Row or Pattern Type: for standard lengths available: see 'elements' specification sheet R nominal length row (specify in feet) M exact length row (specify in inches to nearest 100th”) pattern options "L" overhead - wall to ceiling "L" horizontal/perimeter - wall to adjacent wall "L" flat - wall only "L" flat - ceiling only "U" flat - wall only "U" flat - ceiling only "U" horizontal/perimeter - wall to wall to wall "U" - wall to ceiling to wall rectangle/square flat - wall only rectangle/square flat - ceiling only custom pattern type 1 2 3 4 Finish: T W B O C Options: D E F M N C O P K Q MRI recessed accoLED 5 ____x____ ____x____x____ ____x____x____x____ for angles other than 90° use P and specify in submittals Mounting: flush gyp/hard lid - no finish G 1" regressed gyp - optional finish RG trim flange - choose finish XP t-bar 9/16” - no finish T t-bar 15/16” - no finish X t-bar 9/16” slot - no finish N 4” on center standard t-bar - no finish T4 4” on center slot t-bar - no finish 5 N4 D decoustics ceilencio® - no finish shadowmold + flush gyp - no finish Z shadowmold + 9/16" t-bar - no finish Y shadowmold + 15/16" t-bar - no finish U shadowmold + 5" regressed gyp - optional finish RG5 custom C LED Output: LED standard output LS LED high output LH LED Temp: 3000k 30 3500k 35 4000k 40 Optics: High Efficiency WISP™ lens (recommended) patent pending S HTLO™ lens H HTLO™ vertical HTLO™ vertical + horizontal universal 120V - 277V 347V (remote transformer required) integrations HE WISP™ lens HV HVH Voltage: U 3 w w w.al i ghts .c om Version | Nov 2014 4