recessed - LumiGroup

advertisement
G5
recessed
29
G5
| architrave 5
elements
direct
recessed 5"
LED
5”
5”
WISP™
+
HTLO™
4-3/4” aper ture
LED
per foot
LS
LH
Numerous lamping/optic/flange configurations available.
LED + lens + gyp flange shown as example.
Do not use above dimensions as a subsitute for installation instructions.
1 board in cross
watts/ft
lumens/ft
5
600
10
1200
Lumens at board at 4000k.
Consult IES files online for delivered lumens.
Specifications subject to change.
Available Light Engines:
LED
2
T5
T8
Available Mounting:
MR 16
controls
friendly
recessed
w w w.al i ghts .c om
a·light
| architrave 5
project
type
quantity
interior
exterior
Series:
Dimension:
4
8
12
R16
R20
R24
Lamping:
LED standard output (5w / ft)
LS
LED high output (10w / ft)
LH
T5 (1)
S
T5HO (1)
H
T5 (2)
D
T5HO (2)
O
T5 staggered 8 2
T5HO staggered 8 4
T8 (1) low output
T8L
T8 (1) standard output
T8S
T8 (1) high output
T8H
T8 (2) low output
T8LD
T8 (2) standard output
T8SD
T8 (2) high output
T8HD
T8 staggered low output 8 T8LS
T8 staggered standard output 8 T8SS
T8 staggered high output 8 T8HS
MR16 modules (2) 7 3
LED Temp (if applicable):
3000k
30
3500k
35
4000k
40
Voltage:
universal 120V - 277V
U
120V
1
277V
2
347V (not available for LED)
3
nominal 4’
nominal 8’
nominal 12’
nominal 16’ row
nominal 20' row
nominal 24’ row
See page 4 for detailed options
Legend:
1.
Standard multi-circuiting: see fixture chart on page 4.
2.
Standard on/off occupancy sensor: Wattstopper FS-205 with minimal 1”
diameter.
3.
Standard occupancy sensor with photocell: Wattstopper FS-205 wired for
daylight harvesting. Requires 0-10V dimming ballast.
4.
Lens is required for use in wet or natatorium locations.
5.
Not available with staggered or dual lamping.
6.
Staggered lamping not recommended with HTLO™.
7.
MR16 modules. 2 modules per fixture, 1 at each end, adds 12” total to luminare
length.
8.
Staggered lamping not available on lengths less than 8ft. 8ft length uses 3-3ft
lamps. 12ft uses 2-3ft and 2-4ft lamps.
9.
Not available with LED.
10. 6" on-center utility: 1/4" of exposed raw aluminum flange will be visible if a finish
is not chosen.
optics:
LED
LED
Fluorescent
WISP™ lens (recommended LED optic)
a·cirrus™ lens
WISP™
even distribution
(S)
a·cirrus™
shows LED pattern
(A)
HTLO™ horizontal lens
6
a·wash™ kicker + lens: choose “A”, “H” or “S”
FIT™ white louver
FIT™ aluminum louver
5
a·lenszilla™ white louver + a·cirrus™ lens
a·lenszilla™ white louver + HTLO™ lens
a·lenszilla™ aluminum louver + a·cirrus™ lens
a·lenszilla™ aluminum louver + HTLO™ lens
a·graze™ white louver + specular reflector
35 or 37W MR16 module
20W MR16 module
Fluorescent
WISP™
even distribution
(S)
a·cirrus™
(A)
HTLO™
horizontal
(H)
flush gyp/hard lid - no finish
regressed gyp - optional finish
trim flange - choose finish
t-bar 9/16” - no finish
t-bar 15/16” - no finish
t-bar 9/16” slot - no finish
6” utility standard t-bar - optional finish
6” utility slot t-bar - optional finish
FIT™
white louver
(ZW)
a∙lightanium™
satin white
satin black
other - specify RAL#
no finish (t-bar or gyp)
MR16
(MF2 or MZ2)
elements
G5
dimming - 0-10 unless otherwise specified
emergency - specify model/series or lumens
external fusing
multi-circuit
new york city code
chicago plenum code
occupancy sensor
photocell/daylight sensor
natatorium application
wet label
w w w.al i ghts .c om
Version | March 2014
recessed
G5
Optics:
S
A
H
K__
ZW
9
ZA
ZWA
ZWH
ZAA
ZAH
5
GW
7
MF2
7
MZ2
Mounting:
G
RG
XP
T
X
N
10
T6
10
N6
Finish:
T
W
B
O
Options:
D
E
F
1
M
N
C
2
O
3
P
4
K
4
Q
9
3
G5
| architrave 5
elements
Mounting:
Flush Gypsum/Hard Lid Ceiling or Wall: “Flangeless” appearance for gyp or other
hard ceiling/wall. Flange is not visible and is not factory-painted. Raw aluminum
flange must be attached to blocking (by others), mudded over and painted by ceiling
contractor for flangeless appearance.
1” Regressed Gypsum/Hard Lid Ceiling or Wall: Same as above except regressed
flange raises lens 1” into ceiling resulting in a 6” height. Interior 1" regressed
portion is exposed raw aluminum and visible on both sides unless finish is chosen.
Contractor should apply ceiling paint if finish is not chosen.
Trim Flange: 1/2” visible powdercoated flange. Use for any gyp or hard ceiling/wall
that requires a minimal flange covering the ceiling cut-out edge. Choose finish color
for trim flange.
Construction:
60% recycled aluminum extruded housing. Steel endcap for T-Bar flanges,
milled aluminum endcap for gyp or trim flange.
Finish:
Electrostatically applied powder coat finish. Finish applies to MR16 module
plates, trim flange and 6" on-center t-bar.
Listing:
UL/CUL. Damp Location.
Wet Label:
Specify in Options.
T-Bar/Grid Ceiling: 9/16” or 15/16” standard T-Bar or 9/16” slot ceiling. Raw
aluminum flange sits on T-Bar, is not visible and is not painted.
6” Armstrong Techzone™ / USG Logix™ / other 6” Utility System: Suitable for use in
6” on-center standard or slot t-bar systems. Raw aluminum flange sits on T-Bar. 1/4"
of flange is exposed and visible on both sides unless finish is chosen.
Lengths:
All length dimensions are nominal, used for general length identification purposes.
Actual lengths may vary by several inches. Lengths to 12' are individual fixtures
and do not connect. Lengths beginning with "R" designate standard, nominal rows
comprised of 4' and/or 8' sections.
Specify all modifications with the “integrations” specification sheet: nominal lengths
other than the standards available here, rows longer than 24', exact lengths,
patterns, shadowmolding or other mount types.
MR16 Modules:
See MR16 Addendum on www.alights.com for lamp recommendations. Use
encapsulated 20w or 35w aluminized reflector or 20w or 37w IR MR16 lamps only
(not included).
LED:
5yr warranty. >60,000hr LED life. Tested to LM-79 and LM-80. See wattage/
lumen table for specifications per foot. All specifications are subject to change.
Built with high-performance Nichia® LED’s. Heat sync designed to ensure proper
performance. LED boards are replaceable, built in foot-long increments. Board
position/quantity to be determined by factory.
Wet label standards G5:
4-12’ length
Fixture is gasketed on endcaps with drilled weep holes.
Terminate via wet-rated connector (by others).
R16, R20, R24
Fixture is gasketed on endcaps, with drilled weep holes.
Terminate via wet-rated connector (by others).
Gasketing at each section is not required for direct applications.
Companion Luminaires:
G3 suspended/ceiling/wall
2’, 3’, 4’:
Driver:
Constant Current LED Systems:
Inherent dimming
Power Factor > 90%
90°C case rating
Inherent short-circuit protection
<20% total harmonic distortion
Extreme low-temperature performance to -40°C
Sound rating A
UL/CSA Listed Class 2 rating
IP66 rated
Universal 120-277V
Output:
LS_ _: LED standard output
600 lm/ft
5 watts/ft
LH_ _: LED high output
1200 lm/ft
10 watts/ft
8’:
Multi-circuit standards
12’:
Color Temp:
85CRI is standard; 90+ is available upon request. Insert a 2-digit number for color temp after the LED nomenclature.
30 = 3000 K
35 = 3500 K
40 = 4000 K
Consult factory for special order color temperatures.
LED Optics:
WISP™ lens is the factory standard recommendation for use with LED. Available options are dependent upon a particular luminaire.
Review “Legend” section of the specification sheet to determine any
restrictions in using various optics. Consult factory prior to specification.
T5/T5HO:
Single, dual or staggered lamps in cross section. Program start is factory standard.
T8:
Single, dual or staggered lamps in cross section. Instant start is factory standard:
choose low <0.8BF; standard 0.8-1.0BF; high >1.0BF. Specify if program start or
custom ballast factor is required.
4
w w w.al i ghts .c om
a·light
Download