G5 recessed 29 G5 | architrave 5 elements direct recessed 5" LED 5” 5” WISP™ + HTLO™ 4-3/4” aper ture LED per foot LS LH Numerous lamping/optic/flange configurations available. LED + lens + gyp flange shown as example. Do not use above dimensions as a subsitute for installation instructions. 1 board in cross watts/ft lumens/ft 5 600 10 1200 Lumens at board at 4000k. Consult IES files online for delivered lumens. Specifications subject to change. Available Light Engines: LED 2 T5 T8 Available Mounting: MR 16 controls friendly recessed w w w.al i ghts .c om a·light | architrave 5 project type quantity interior exterior Series: Dimension: 4 8 12 R16 R20 R24 Lamping: LED standard output (5w / ft) LS LED high output (10w / ft) LH T5 (1) S T5HO (1) H T5 (2) D T5HO (2) O T5 staggered 8 2 T5HO staggered 8 4 T8 (1) low output T8L T8 (1) standard output T8S T8 (1) high output T8H T8 (2) low output T8LD T8 (2) standard output T8SD T8 (2) high output T8HD T8 staggered low output 8 T8LS T8 staggered standard output 8 T8SS T8 staggered high output 8 T8HS MR16 modules (2) 7 3 LED Temp (if applicable): 3000k 30 3500k 35 4000k 40 Voltage: universal 120V - 277V U 120V 1 277V 2 347V (not available for LED) 3 nominal 4’ nominal 8’ nominal 12’ nominal 16’ row nominal 20' row nominal 24’ row See page 4 for detailed options Legend: 1. Standard multi-circuiting: see fixture chart on page 4. 2. Standard on/off occupancy sensor: Wattstopper FS-205 with minimal 1” diameter. 3. Standard occupancy sensor with photocell: Wattstopper FS-205 wired for daylight harvesting. Requires 0-10V dimming ballast. 4. Lens is required for use in wet or natatorium locations. 5. Not available with staggered or dual lamping. 6. Staggered lamping not recommended with HTLO™. 7. MR16 modules. 2 modules per fixture, 1 at each end, adds 12” total to luminare length. 8. Staggered lamping not available on lengths less than 8ft. 8ft length uses 3-3ft lamps. 12ft uses 2-3ft and 2-4ft lamps. 9. Not available with LED. 10. 6" on-center utility: 1/4" of exposed raw aluminum flange will be visible if a finish is not chosen. optics: LED LED Fluorescent WISP™ lens (recommended LED optic) a·cirrus™ lens WISP™ even distribution (S) a·cirrus™ shows LED pattern (A) HTLO™ horizontal lens 6 a·wash™ kicker + lens: choose “A”, “H” or “S” FIT™ white louver FIT™ aluminum louver 5 a·lenszilla™ white louver + a·cirrus™ lens a·lenszilla™ white louver + HTLO™ lens a·lenszilla™ aluminum louver + a·cirrus™ lens a·lenszilla™ aluminum louver + HTLO™ lens a·graze™ white louver + specular reflector 35 or 37W MR16 module 20W MR16 module Fluorescent WISP™ even distribution (S) a·cirrus™ (A) HTLO™ horizontal (H) flush gyp/hard lid - no finish regressed gyp - optional finish trim flange - choose finish t-bar 9/16” - no finish t-bar 15/16” - no finish t-bar 9/16” slot - no finish 6” utility standard t-bar - optional finish 6” utility slot t-bar - optional finish FIT™ white louver (ZW) a∙lightanium™ satin white satin black other - specify RAL# no finish (t-bar or gyp) MR16 (MF2 or MZ2) elements G5 dimming - 0-10 unless otherwise specified emergency - specify model/series or lumens external fusing multi-circuit new york city code chicago plenum code occupancy sensor photocell/daylight sensor natatorium application wet label w w w.al i ghts .c om Version | March 2014 recessed G5 Optics: S A H K__ ZW 9 ZA ZWA ZWH ZAA ZAH 5 GW 7 MF2 7 MZ2 Mounting: G RG XP T X N 10 T6 10 N6 Finish: T W B O Options: D E F 1 M N C 2 O 3 P 4 K 4 Q 9 3 G5 | architrave 5 elements Mounting: Flush Gypsum/Hard Lid Ceiling or Wall: “Flangeless” appearance for gyp or other hard ceiling/wall. Flange is not visible and is not factory-painted. Raw aluminum flange must be attached to blocking (by others), mudded over and painted by ceiling contractor for flangeless appearance. 1” Regressed Gypsum/Hard Lid Ceiling or Wall: Same as above except regressed flange raises lens 1” into ceiling resulting in a 6” height. Interior 1" regressed portion is exposed raw aluminum and visible on both sides unless finish is chosen. Contractor should apply ceiling paint if finish is not chosen. Trim Flange: 1/2” visible powdercoated flange. Use for any gyp or hard ceiling/wall that requires a minimal flange covering the ceiling cut-out edge. Choose finish color for trim flange. Construction: 60% recycled aluminum extruded housing. Steel endcap for T-Bar flanges, milled aluminum endcap for gyp or trim flange. Finish: Electrostatically applied powder coat finish. Finish applies to MR16 module plates, trim flange and 6" on-center t-bar. Listing: UL/CUL. Damp Location. Wet Label: Specify in Options. T-Bar/Grid Ceiling: 9/16” or 15/16” standard T-Bar or 9/16” slot ceiling. Raw aluminum flange sits on T-Bar, is not visible and is not painted. 6” Armstrong Techzone™ / USG Logix™ / other 6” Utility System: Suitable for use in 6” on-center standard or slot t-bar systems. Raw aluminum flange sits on T-Bar. 1/4" of flange is exposed and visible on both sides unless finish is chosen. Lengths: All length dimensions are nominal, used for general length identification purposes. Actual lengths may vary by several inches. Lengths to 12' are individual fixtures and do not connect. Lengths beginning with "R" designate standard, nominal rows comprised of 4' and/or 8' sections. Specify all modifications with the “integrations” specification sheet: nominal lengths other than the standards available here, rows longer than 24', exact lengths, patterns, shadowmolding or other mount types. MR16 Modules: See MR16 Addendum on www.alights.com for lamp recommendations. Use encapsulated 20w or 35w aluminized reflector or 20w or 37w IR MR16 lamps only (not included). LED: 5yr warranty. >60,000hr LED life. Tested to LM-79 and LM-80. See wattage/ lumen table for specifications per foot. All specifications are subject to change. Built with high-performance Nichia® LED’s. Heat sync designed to ensure proper performance. LED boards are replaceable, built in foot-long increments. Board position/quantity to be determined by factory. Wet label standards G5: 4-12’ length Fixture is gasketed on endcaps with drilled weep holes. Terminate via wet-rated connector (by others). R16, R20, R24 Fixture is gasketed on endcaps, with drilled weep holes. Terminate via wet-rated connector (by others). Gasketing at each section is not required for direct applications. Companion Luminaires: G3 suspended/ceiling/wall 2’, 3’, 4’: Driver: Constant Current LED Systems: Inherent dimming Power Factor > 90% 90°C case rating Inherent short-circuit protection <20% total harmonic distortion Extreme low-temperature performance to -40°C Sound rating A UL/CSA Listed Class 2 rating IP66 rated Universal 120-277V Output: LS_ _: LED standard output 600 lm/ft 5 watts/ft LH_ _: LED high output 1200 lm/ft 10 watts/ft 8’: Multi-circuit standards 12’: Color Temp: 85CRI is standard; 90+ is available upon request. Insert a 2-digit number for color temp after the LED nomenclature. 30 = 3000 K 35 = 3500 K 40 = 4000 K Consult factory for special order color temperatures. LED Optics: WISP™ lens is the factory standard recommendation for use with LED. Available options are dependent upon a particular luminaire. Review “Legend” section of the specification sheet to determine any restrictions in using various optics. Consult factory prior to specification. T5/T5HO: Single, dual or staggered lamps in cross section. Program start is factory standard. T8: Single, dual or staggered lamps in cross section. Instant start is factory standard: choose low <0.8BF; standard 0.8-1.0BF; high >1.0BF. Specify if program start or custom ballast factor is required. 4 w w w.al i ghts .c om a·light