Recessed: G = gyp ceiling / RG = regressed gyp ceiling
Installation Drawing
Applicable luminaires:
ACL5 | D5 | D7 | E5 | G5
A
2
GYP
BLOCKING
B
1. For cutout length, consult
sizing chart (page 2) and/or
submittal drawings.
1. Remove the lens or louver.
2. Wood or steel studs may
be used.
1
• Apply suction cup (provided) to
one end and carefully pull
lens out.
3. Install gyp board, then cut
opening.
1
3
4. Cut-out widths:
ROUGH
OPENING
4
Blocking as
seen from
above
• Louvers should be carefully
removed by hand.
2
Series
Min
Max
ACL:
2.45”
2.70”
D:
3.75”
4.00”
E:
2.20”
2.45”
G:
5.25”
5.50”
2. Remove reflectors and LED
gear tray or ballast kits by unfastening hardware.
D
ck
ing
C
1. Lift fixture into place and
draw flange up snuggly under
bottom of gyp board.
2. Connect wiring between
housings using the provided quick
connects.
ck
Blo
Gypsum
1
NOTE: A perture size must be
maintained (do not stretch side
flanges).
4. Secure extrusions with joiner
brackets using a threaded rod
or bolt with flange nuts (provided).
3
3. Attach fixture to blocking
(through gyp) with #8 drywall
screws in the pre-drilled holes
in side flanges. Fixture must be
fastened to blocking through
holes at a minimum of every 8”
or less.
4. Attach tie-off cables (by
others) to fixture endcap holes
and to structure as per code.
3. Line up pins and bang extrusion
pieces together using a mallet until
no gap remains.
4
1
ing
1. When rows are ordered: row
sections will be labeled in
sequence. Position sections in
proper order prior to installation.
(ie: Place 1 next to 1).
2
2. Wire fixture through KO hole
per local codes.
Blo
Rows:
FLANGES SHOULD BE BENEATH
WALL/CEILING SURFACE
E
1. Mud over side and end
flanges to edge of fixture.
Finish should just cover
bottom extrusion edge so it is
not seen.
2
1
MUD
Blocking
2. Tape off and paint wall/
ceiling up to and including
extrusion edge.
3. Install LED or fluorescent
gear tray and reflectors. Install
lamps in fluorescent fixtures (by
others.)
4. Insert lens or louver. Lens
may have optical inserts.
3
Gypsum
4
ATTENTION:
*CONSULT LOCAL BUILDING CODE AUTHORITIES FOR
INSTALLATION REQUIREMENTS AND APPROVALS.
*WARNING: RISK OF FIRE AND ELECTRICAL SHOCK. FIXTURE
INSTALLATION REQUIRES KNOWLEDGE OF FLUORESCENT
LIGHTING ELECTRICAL SYSTEMS. IF NOT QUALIFIED, DO NOT
ATTEMPT INSTALLATION. CONTACT A QUALIFIED ELECTRICIAN.
*WARNING: RISK OF FIRE AND ELECTRICAL SHOCK. FIXTURE
BALLAST WIRE, OR OTHER ELECTRICAL COMPONENTS MAY
BE DAMAGED WHEN DRILLING FOR INSTALLATION OF FIXTURE
TO WALL OR CEILING. CHECK FOR ENCLOSED WIRE AND
COMPONENTS.
*WARNING: TO PREVENT WIRE DAMAGE OR ABRASION, DO NOT
EXPOSE WIRES TO EDGES OF SHEET METAL OR OTHER SHARP
OBJECT. DO NOT MAKE OR ALTER ANY OPEN HOLES IN AN
ENCLOSURE OF WIRE OR ELECTRIC COMPONENT DURING FIXTURE
INSTALLATION.
LED D5 fixture
shown
3728 mari time way oceans ide , ca 9205 6
p. 760.727.7675
a·light |
© Nov 2014
Recessed: G = gyp ceiling / RG = regressed gyp ceiling
Applicable luminaires:
Installation Drawing
ACL5 | D5 | D7 | E5 | G5 | G6
Notes
Applicable Luminaires
* Always consult submittal drawings (if applicable) for run length cutouts as special lengths may have been ordered.
G
gyp
RG
regressed gyp
ACL5
ACL5
D5
D5
* When ordering, note the difference between aperture length and
cut-out length in areas with tight architectural constraints.
* For staggered lamping, note that almost any target length is
possible by varying stagger length and lamp size, so consult factory
for special sizes.
* IMPORTANT: Aperture size MUST be maintained. Do not stretch
Sizing Chart for Cutout Lengths
n/a
D7