INSTALLATION INSTRUCTIONS

IMPORTANT: READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN FOR FUTURE REFERENCE.

GENERAL

: Upon receipt of the fixture, thoroughly inspect for any freight damage which should be brought to the attention of the delivery carrier.

Compare the catalog description listed on the packing slip with the fixture label on the housing to assure you have received the correct material.

CFDP Series CFL

High-Low Bay

Sheet 1 of 3

6/25/09 IMI-708

SAFETY

: This fixture must be wired in accordance with the National

Electrical Code and applicable local codes and ordinances. Proper grounding is required to insure personal safety. Carefully observe grounding procedure under installation section.

WARNING

: Risk of Fire/Shock. If not qualified, consult an electrician.

Risk of Electric Shock. Disconnect power at fuse or circuit breaker panel or fuse box before installing or servicing.

APPLICATION:

NOTE: DO NOT EXCEED AMBIENT TEMPERATURE RATINGS LISTED IN TABLE BELOW.

Catalog Number

AC22 - Acrylic Reflector

AC22 - Acrylic Reflector with DB22 - Drop Bottom Lens

AC22 - Acrylic Reflector with CB22 - Conical Bottom Lens

40°C

X

AC22 - Acrylic Reflector with SGB22 - Safety Glass Bottom

SA22 - Spun Aluminum Reflector

SA22 - Spun Aluminum Reflector with DB22 - Drop Bottom Lens

X

N/A

SA22 - Spun Aluminum Reflector with CB22 - Conical Bottom Lens N/A

SA22 - Spun Aluminum Reflector with SGB22 - Safety Glass Bottom N/A

I42EMB - Internal 32-42W Emergency Ballast

DIM - DIMMING BALLAST

25°C Only

X

X

X

N/A

N/A

N/A

X

X

NOTE: NOT FOR OUTDOOR USE.

1. Feed incoming line leads through bushing at top of fixture and thread 3/4" pendant or rigid conduit

(not supplied) into bushing. Tighten set screw FIG. 1 .

2. Loosen locknut and slide locknut, washer and ballast housing cover up pendant to access wiring compartment.

Splice incoming supply leads to fixture leads FIG. 2 .

NOTE: TO INSURE PROPER GROUNDING AND POLARITY:

USE SUPPLY LEADS RATED FOR 90°C MIN. Splice incoming supply LINE, NEUTRAL and GROUND leads to corresponding ballast LINE (black) lead, NEUTRAL (white) lead and fixture

GROUND (green) lead. If you are unsure which lead wire is

LINE, NEUTRAL or GROUND, consult an electrician.

Bushing

3/4" Pendant

(By Others)

3/14-14

NPS THD

Set Screw

Notes

Open Bottom (No Lens) Only

Open Bottom (No Lens) Only

NOT AVAILABLE

NOT AVAILABLE

NOT AVAILABLE

Washer

Wiring

Compartment

Ballast

Housing

Locknut

Ballast Housing

Cover

FIG. 1

FIG. 2

These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact your nearest representative.

NOTE: Specifications and dimensions subject to change without notice.

Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 ADH090075

INSTALLATION INSTRUCTIONS

IMPORTANT: READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN FOR FUTURE REFERENCE.

GENERAL

: Upon receipt of the fixture, thoroughly inspect for any freight damage which should be brought to the attention of the delivery carrier.

Compare the catalog description listed on the packing slip with the fixture label on the housing to assure you have received the correct material.

CFDP Series CFL

High-Low Bay

Sheet 2 of 3

6/25/09 IMI-708

SAFETY

: This fixture must be wired in accordance with the National

Electrical Code and applicable local codes and ordinances. Proper grounding is required to insure personal safety. Carefully observe grounding procedure under installation section.

WARNING

: Risk of Fire/Shock. If not qualified, consult an electrician.

Risk of Electric Shock. Disconnect power at fuse or circuit breaker panel or fuse box before installing or servicing.

3. Re-assemble ballast housing cover to wiring compartment and tighten locknut. Remove three (3) wing nuts and three (3) fender washers FIG. 3 .

4. Assemble reflector (ordered separately) to ballast housing using three (3) wing nuts and three (3) fender washers FIG. 4 .

Ballast Housing

Cover

Do not remove jam nut

Fender Washer

FIG. 3

Wing Nut

5. Install lamps.

NOTE: To insure proper lamp retention, high temperature TWIST LOCK lamp holders are used. To install lamps, insert lamp and turn clockwise FIG. 5 .

FIG. 4

Fender Washer

Wing Nut

FIG. 5

These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact your nearest representative.

NOTE: Specifications and dimensions subject to change without notice.

Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 ADH090075

INSTALLATION INSTRUCTIONS

IMPORTANT: READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN FOR FUTURE REFERENCE.

GENERAL

: Upon receipt of the fixture, thoroughly inspect for any freight damage which should be brought to the attention of the delivery carrier.

Compare the catalog description listed on the packing slip with the fixture label on the housing to assure you have received the correct material.

CFDP Series CFL

High-Low Bay

Sheet 3 of 3

6/25/09 IMI-708

SAFETY

: This fixture must be wired in accordance with the National

Electrical Code and applicable local codes and ordinances. Proper grounding is required to insure personal safety. Carefully observe grounding procedure under installation section.

WARNING

: Risk of Fire/Shock. If not qualified, consult an electrician.

Risk of Electric Shock. Disconnect power at fuse or circuit breaker panel or fuse box before installing or servicing.

EMERGENCY BATTERY

(FOR USE IN 25°C AMBIENT MAX.)

Emergency Ballast is pre-wired in the factory to the designated voltage specified on the order.

Battery Connectors

NOTE:

DO NOT MATE CONNECTORS

UNTIL INSTALLATION IS COMPLETE

AND A.C. POWER IS SUPPLIED.

These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact your nearest representative.

NOTE: Specifications and dimensions subject to change without notice.

Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 ADH090075

Download