Fluorescent High Bay for High Mounting Applications lumen maintenance comparison hid vs. fluorescent 40000 30000 total lumen output 400W M-H 4X54W T5HO 20000 6X54W T5HO 6X32 T8 (PLUS) 10000 00 0 0 36 00 0 32 00 00 28 0 24 0 00 00 20 00 16 0 00 12 0 80 00 40 0 0 hours of operation h.i.d. • Metal Halide (MH) has traditionally been the common solution in High Bay applications. • Superior optical design puts the light where you want it. • Good initial fixture light output. • Wide temperature range – operates reliably in areas where temperatures can exceed 120˚ F or fall below 50˚ F. • Can operate in severe environments that are corrosive or extremely dirty. Contents H.I.D. vs. Fluorescent . . . . . .1, 2 Energy Savings . . . . . . . . . . .3, 4 I5/I8 Series . . . . . . . . . . . . . .5, 6 HB Series . . . . . . . . . . . . . . . .7, 8 HBO Series . . . . . . . . . . . . . . . . .9 High Ambient Applications . .10 MB Series . . . . . . . . . . . . . . . . .11 2HBG, 2HBHD Series . . . . . .12 Options & Accessories . .13, 14 I5/I8, HB Ordering . . . . . . . . .15 HBO, HA, MB Ordering . . . . .16 2HBG, 2HBHD Ordering . . . .17 F-Bay Application . . . . . . . . . . .18 1 thermal effect on fluorescent and hid lamps 20 00 relative lumen output % 80 HID 60 T8 T5HO 40 20 0 0 5 10 15 20 25 30 35 40 45 50 55 60 temperature in ˚c fluorescent high bays • Energy Savings – 30-50% energy reduction for comparable light levels. • Superior Lumen Maintenance – maintain 90-95% of initial light output and extended life. Last 25,000 hours based on 10 hour starts. • Improved Color Rendering – Fluorescent maintains consistent color through life and has a color rendering index (CRI) of 85...improves visual acuity! • Instant On/Off – in an event of power interruption, fluorescent lamps are back on instantly. Integral stand-by emergency battery packs are also available. • More Energy Savings – Instant on/off makes fluorescent control friendly. Use with motion sensors to further reduce energy consumption. Dimming is also an option. Reduce Energy Costs..... Save Money! 2 linear fluorescent replaces 400w metal halide one for one..... with half the energy. additional benefits f-bay f-bay metalux 2hb-632 metalux i5-454t5 400w metal halide 22,302 20,000 36,000 Lamp Lumen Depreciation .93 .95 .60 Avg. Fixture Efficiency .937 .936 .887 19,434 17,784 19,159 226 Watts 232 Watts 455 Watts 86 77 42 fixture comparison: Initial Lumens Maintained (Useable) Lumens Energy Consumed Maintained Lumens/Watt (LPW) the standard Three to six lamp T5 or T8 cross-section allow Cooper’s F-Bays to be used in many applications and various mounting heights. F-Bays can be customized with many options and accessories to match specific requirements. • Lumen uniformity with reduced direct glare. • Negligible color shift throughout life. • Linear source reduces troublesome shadows. • Environmentally friendly by reducing green house gases through energy reductions. According to EPA conversion guidelines, emissions pollution reductions over ten years are estimated to be equivalent to: planting 320 million trees, removing 247 million cars, and saving 158 billion gallons of gasoline. f-bay f-bay metalux 2hb-632 metalux i5-454 350w pulse start 400w high bay Footcandles produced with new lamps 26 24 38 40 Footcandles after 10,000 hours 25 23 25 27 Footcandles after 16,000 hours 24 23 23 24 Energy Consumed 225W 232W 386W 455W light level comparison: Spacing= 25' Centers Mounting Height= 31' Luminaire Dirt Depreciation= 0.88 Lamp Lumen Depreciation= 0.6 (M.H.) 0.93 (T8) 0.95 (T5HO) save energy! Visit Cooper Lighting’s website www.cooperlighting.com and click on F-Bay Payback Calculator for a financial analysis of your lighting needs. 3 a visible and money saving difference The purpose of this example is to determine the energy savings associated with replacing Metal Halide fixtures currently installed with Cooper Lighting’s F-Bay fixtures. The analysis assumes one for one fixture replacement so that current electrical supply connections do not have to be relocated. The major considerations are: • F-Bays reduce energy costs by 50% • F-Bays generate comparable or better light levels • Occupancy sensors can further reduce energy costs by another 50% • Improved color rendering enhances visual acuity Application: Warehouse/Distribution Center Building Size: 700 x 350 x 35 metal halide 400w f-bay 2hb-632 (plus) f-bay hb-454t5 w/acrylic refractor w/6% uplight component w/6% uplight component fixture type Layout Lamp & Fixture Data Footcandles Operating Data Savings Analysis Space Utilization: 9' Wide Aisles w/ 25' High Racking Existing Lighting: (500) 400W MH w/Acrylic Refractor FIXTURE MOUNTING HEIGHT 31' 31' 31' FIXTURE SPACING 25' 25' 25' INITIAL LAMP LUMENS 36,000 3,150 4,400 NUMBER OF LAMPS 1 6 4 INITIAL FIXTURE LUMENS 36,000 18,900 17,600 BALLAST FACTOR 1.0 1.18 1.0 INITIAL FIXTURE LUMENS (ballast corrected) 36,000 22,302 17,600 LAMP LUMEN DEPRECIATION 0.6 0.93 0.95 LUMINAIRE DIRT DEPRECIATION 0.88 0.88 0.88 FIXTURE EFFICIENCY .887 0.937 0.936 MAINTAINED FIXTURE LUMENS 16,860 17,102 13,772 232 FIXTURE WATTS 455 226 FIXTURE LUMENS/WATT 37 76 59 CRI 70 85 85 FC BELOW FIXTURE 26 27 23 FC BETWEEN FIXTURES 20 23 22 VERTICAL FC 7.3 7.0 7.6 NUMBER OF FIXTURES 500 500 500 SYSTEM KW 227.5 113 116 COST PER KWH $0.08 $0.08 $0.08 HRS/DAY 24 24 24 DAYS/WEEK 7 7 7 WEEKS/YEAR 52 52 52 TOTAL HRS/YEAR 8,736 8,736 8,736 ANNUAL ENERGY COSTS $158,995 $78,973 $81,070 $80,021 $77,925 ANNUAL SAVINGS 4 Surface or suspension mounting (cable, chain, pendant mount or top connector box) Optional uplight apertures (approximately 8% uplight component) White enamel finish improves efficiency and protects from corrosion Latched retention of optics (safety leader restraints) allows for easy access Occupancy sensor is availble to instantly turn lights on and off. Saves more energy! Modular optics include open, lens, wireguard, crossblade or asymmetric directional louver 2, 3 & 4 lamp versions in nominal 4' and 8' tandem models UL/CUL listed to meet U.S and Canadian safety standards Optical distribution options allow for precise light control Aisle - enhanced specular aluminum. Minimum 95% total reflectivity General - paint-after-fabrication polyester powder coat. Minimum 90% total refectivity (see below for photo) The F-Bay I5/I8 series is an ideal solution for high mounting height i5 & i8 optical distributions industrial or retail applications with an attractive, professional style. F-Bay I5/I8 optics have been optimized to provide maximum performance from either T5 or T8 lamps. Optional uplight component is available to enable excellent ceiling uniformity. 5 Narrow Aisle – General Ambient – (Specular Enhanced Aluminum) (White Painted Finish) i5 & i8 shielding optics Open – For Frosted Acrylic Lens maximum light output – In white doorframe w/”Herringbone” patterned end rail Heavy Duty Wire Guard – Finished in white. Can be used alone or in combination with other shielding TBW– Thin Blade White Asymmetric Louver – Can Baffle w/23˚ longitudinal shielding be oriented in either direction for flexibility i5 & i8 application suitability matrix i5 & i8 lamp configurations 3-lamp t5/t8 2-lamp t5/t8 i5/i8 4-15/16" [126mm] 4-15/16" [126mm] 4-5/8" [118mm] 11" [280mm] X=2-3/4" [70mm] # Lamps Source X 3 T5HO 4 T5HO 3 T8 4 T8 X 11" [280mm] 4-lamp t5/t8 4-15/16" [126mm] 4-15/16" [126mm] X=2-11/32" [60mm] 2-lamp biax X X 4-5/8" [118mm] 11" [280mm] X 11" [280mm] mounting height 40' 30' 20' 4-lamp biax 3-lamp biax 10' X=2-3/4" [70mm] X X 11" [280mm] X=2-11/32" [60mm] X X X 11" [280mm] applications replaces 4-15/16" [126mm] 4-15/16" [126mm] 400W HID 400W HID 250W HID 250W HID Warehouse Manufacturing Gymnasium Auditorium Convention Ctr Big-Box Retail Warehouse Manufacturing Gymnasium Auditorium Convention Ctr Big-Box Retail Manufacturing Retail Cafeteria Manufacturing Retail Cafeteria 6 Surface or suspension mounting (cable, chain, pendant mount or top connector box) Optional uplight apertures (approximately 8% uplight component) Occupancy sensor is availble to instantly turn lights on and off. Saves more energy! White enamel finish improves efficiency and protects from corrosion Modular optics include open, wireguard or lens 4 and 6 lamp downlight lamp versions 24" and 15" wide housings 4' models only UL/CUL listed to meet U.S and Canadian safety standards Optical distribution options allow for precise light control Aisle - enhanced specular aluminum. Minimum 95% total reflectivity General - paint-after-fabrication polyester powder coat. Minimum 90% total refectivity (see below for photo) The HB series is an ideal solution for high mounting height industrial hb optical distributions or retail applications. F-Bay HB optics have been optimized to provide maximum performance from either T5 or T8 lamps. Optional uplight component is available to enable excellent ceiling uniformity. Narrow Aisle – (Specular Enhanced Aluminum) 7 General Ambient – (White Painted Finish) hb shielding optics Open – For maximum light output Heavy-Duty Wireguard and Lens – Finished in white. Acrylic Lens – A wide choice Thin Blade White Baffle – of acrylic lenses in a white extruded steel doorframe (G1 & G2 optional) Finished in white. hb lamp configurations hb application suitability Matrix 2-lamp t5/t8 hb 4-3/4" [121mm] X=6-5/16" [161mm] # Lamps Source X 4 T8 4 T5HO 4 T8 4 T5HO 6 T8 6 T5HO 250-400W HID 250-400W HID 250-400W HID 250-400W HID 250-400W HID 250-400W HID Warehouse Manufacturing Retail Warehouse Manufacturing Retail Warehouse Manufacturing Gymnasium Auditorium Convention Ctr Big-Box Retail Warehouse Manufacturing Gymnasium Auditorium Convention Ctr Big-Box Retail Warehouse Manufacturing Gymnasium Auditorium Convention Ctr Big-Box Retail Warehouse Manufacturing Gymnasium Auditorium Convention Ctr Big-Box Retail 15-7/16" [392mm] 40' mounting height 3-lamp t5/t8 4-3/4" [121mm] X=3-9/16" [91mm] X X 15-7/16" [392mm] 4-lamp t5/t8 4-3/4" [121mm] X=2-7/8" [74mm] X X X 30' 20' 10' applications replaces 15-7/16" [392mm] 4-lamp t5/t8 4-3/4" [121mm] X=5" [127mm] X X X 24" [610mm] 6-lamp t5/t8 4-3/4" [121mm] X=3-12" [89mm] 2hb X X X X X 24" [610mm] 8 Surface or suspension mounting (cable, chain, pendant mount or top connector box) Optional uplight apertures (approximately 5% uplight component) 4, 6 and 8 lamp versions for HBO (6 & 8 for HBOT) White enamel finish improves efficiency and protects from corrosion hbo lamp configurations 4-lamp t5/t8 Occupancy sensor is availble to instantly turn lights on and off. Saves more energy! 5-1/16"[129mm] X=4" [102mm] X X UL/CUL listed to meet U.S and Canadian safety standards X 16-5/16" [414mm] Optical distribution options allow for precise light control (aisle or general) Aisle - enhanced specular aluminum. Minimum 95% total reflectivity General - paint-after-fabrication polyester powder coat. Minimum 90% total refectivity The HBOT series provides structural rigidity 6-lamp t5/t8 5-1/16"[129mm] X=4" [102mm] X X X X X 24-5/16" [617mm] hbo application suitability matrix 8-lamp t5/t8 5-1/16"[129mm] X=4" [102mm] hbo/hbot X X X X X X 32-5/16" [820mm] X # Lamps Source 4 T8 4 T5HO 6 T8 6 T5HO 8 T8 8 T5HO 250-1000W HID 250-1000W HID 250-1000W HID 250-1000W HID 250-1000W HID 250-1000W HID hbot lamp configurations 40' 5-3/16" [131mm] X=4" [102mm] X X X X X 24-9/16" [624mm] 8-lamp t5/t8 5-3/16" [131mm] X=4" [102mm] X X X X X X 32-11/16" [830mm] X mounting height 6-lamp t5/t8 30' 20' solution for high mounting height industrial or retail applications. The optics have been optimized to provide maximum performance from either T5 or T8 lamps. Optional uplight component is available to enable excellent ceiling uniformity. 9 applications The HBO and HBOT series offer an economical replaces 10' Warehouse Warehouse Warehouse Warehouse Warehouse Warehouse Manufacturing Manufacturing Manufacturing Manufacturing Manufacturing Manufacturing Gymnasium Gymnasium Gymnasium Gymnasium Gymnasium Gymnasium Auditorium Auditorium Auditorium Auditorium Auditorium Auditorium Convention Ctr Convention Ctr Convention Ctr Convention Ctr Convention Ctr Convention Ctr Big-Box Retail Big-Box Retail Big-Box Retail Big-Box Retail Big-Box Retail Big-Box Retail The High Ambient (HA) system, featuring T5HO technology, combines the high quality features of Cooper Lighting’s F-Bay series, such as reliability, energy efficiency and lighting quality with high ambient temperature operation. The HA system is UL listed to operate in environments up to 65˚C. HA features a ballast warranty of five years for ambient temperatures up to 55˚C and three years up to 65˚C. HA delivers 50% or more energy savings over 400W MH and maintains designed light levels. 10 Easily suspended and adjusted with various cable mounting methods Ideal for continuous row mounting in narrow aisle applications (available with long connector for row alignment) White enamel finish improves efficiency and protects from corrosion Occupancy sensor is availble to instantly turn lights on and off. Saves more energy! UL/CUL listed to meet U.S and Canadian safety standards Specular MIRO 4 reflectors for precise light control. Three optical distribution patterns are available Normal - enhanced specular aluminum. Minimum 95% total reflectivity Focus - enhanced specular aluminum. Minimum 95% total reflectivity Task - paint-after-fabrication polyester powder coat. Minimum 90% total refectivity mb lamp configurations focus beam 1 or 2 lamp task beam 1 or 2 lamp X X The F-Bay MB series (Micro-Bay) is a functional and multi-purpose T5 narrow profile fluorescent High- 1-31/32" [51mm] 3-9/32" [84mm] X=2-11/16" [69mm] Bay that incorporates premium 1" [26mm] X=2-11/16" [69mm] 4-5/16" [110mm] X 1-31/32" [51mm] 3-9/32" [84mm] normal beam 1 or 2 lamp 1-7/16" [37mm] 4-5/16" [110mm] 1-31/32" [51mm] 3-9/32" [84mm] X=2-11/16" [69mm] 1-3/16" [31mm] 4-5/16" [110mm] performance and construction focus beam 1 or 2 lamp task beam 1 or 2 lamp normal beam 1 or 2 lamp X X X durability. Designed for both T5 and T8 fluorescent technology, the MB Series offers both high performance and application versatility. 11 T8 3-5/32" [81mm] X=2-11/16" [69mm] 29/32" [24mm] 7-3/16" [183mm] 3-5/32" [81mm] X=2-11/16" [69mm] 29/32" [24mm] 7-9/16" [193mm] 3-5/32" [81mm] X=2-11/16" [69mm] 29/32" [24mm] 7-3/32" [181mm] Modular optics include open, lens or wireguard White enamel finish improves efficiency and protects from corrosion Hole-free housing Particulock gasket system provides 200 psi hose down rating 4 or 6 lamp versions The 2HBG series is an ideal The 2HBHD series is designed Occupancy sensor is availble to instantly turn lights on and off. Saves more energy! solution for high mounting height industrial or retail applications that require a recessed luminaire. The 2HBG for use in high mounting height applications where periodic cleaning with high pressure is required. UL/CUL listed to meet U.S and Canadian safety standards This surface mounted luminaire optics have been optimized to has a hole-free design and is provide maximum performance enclosed and gasketed to provide from either T5 or T8 lamps. 200psi hose down protection. hb application suitability matrix 2hbg lamp configurations 6-lamp t5/t8 2hbg 4-5/8" [117mm] X=3-12" [89mm] X X X X X # Lamps Source 2hbhd 6 T8 6 T5HO 4 T8 4 T5HO 6 T8 6 T5HO 400W HID 400W HID 250-400W HID 250-400W HID 250-400W HID 250-400W HID Retail Convention Center Gymnasium Retail Convention Center Gymnasium Food Processing Industrial Food Processing Industrial Food Processing Industrial Food Processing Industrial 23-3/4" [603mm] 2hbhd lamp configurations 4-lamp t5/t8 4-1/2" [115mm] X=5" [127mm] X X X 23-11/16" [602mm] mounting height 40' 30' 20' 6-lamp t5/t8 10' X X X X 23-11/16" [602mm] X applications X=3-1/2" [89mm] replaces 4-1/2" [115mm] 12 Mounting Options Mounting options.... quickly & securely Chain Cable Stem AYC Chain Set – (2) Sturdy Wire Hooks and 36" Chain Sets c/w S-Hooks. Cable Sets – CCA (48" or 120" adjustable) and CCF (12", 15", 18", 21", 24" or 27" fixed length) Stainless Steel Aircraft Cable Kits. Available in non-power feed and PFC (coil power cord) or PFS (straight power cord). Stem Sets – Fixed, Swivel or Adjustable Stem Sets available in various lengths. “Y” Toggle Loop Hanger Mounting Toggle and 10' or 25' cable 10' or 30' Loop Hanger w/#2 Cable Single Toggle 10' or 30' Single Toggle w/#2 Cable Mounting Options Row Mount End plates provided with the “Quick-Tab” joining system for ease of row mounting. Blank end plates provided for row ends. Cord & Plug Uplight Option 3' or 6' long Power Cord & Plug sets available for various power supply voltages (please specify voltage) Optional uplight component to illuminate the ceiling available on all models. Power Cord Sets 3' or 6' long Power Cord sets also available (please specify voltage) 13 Pre-Lamp Emergency Battery Packs Quick Disconnect Plug Factory installled lamps save labor on jobsites. Self-contained integrally mounted in the fixture operate lamps at emergency levels for 90 minutes upon loss of primary power. Pre-wired between the ballast and the power supply, this feature allows for internal cut-off of power supply for service convenience. Mounting Accessories Two Point Suspension Single Point Cable Kit SINGLE POINT Stainless Steel Cable Kit for single point suspension. (fixture dropped below mounting point by 13") Use with TCB to minimize cantilevering and rotation. TWO POINT (fixture dropped below mounting points by 29") Mounting Accessories Top Connector Box (tcb) Hook & Safety Hook Loop Retrofit Hanger Suitable for conduit mounting or for use with fixture hook, loop or safety hook. (Recommended for use with chain or cable set to prevent cantilevering and rotation from a central mounting point). ideal for retro-fit opportunities!!! Fixture Hook 2-1/2" (must be used with Top Connector Box) Fixture Loop 2-1/2" (must be used with Top Connector Box) Cast Aluminum Hanger w/Togglr Nut & Carriage Bolt for quick installation (must be used with Top Connector Box) Top Ballast Access Plate Allows for removal or service of ballast from above without disturbing internal optics. Occupancy Sensor.... saves more energy! Provides switching capabilities with adjustments for time delay, sensitivity, and lux levels. Designed specifically for aisle lighting applications, it provides a rectangular coverage pattern of 15' x 40' when mounted at a 40' mounting height. Full 360˚ coverage also available. MWS Job Pack Factory installed Modular Wiring System provides low cost installation of branch circuit wiring. Fixtures pallet packed with protective end caps to minimize trash on sites. Unit Pack Fixtures individually packaged with corrugated carton and internal pads. 14 i5/i8 I 5 / I 8 O R D E R I N G I N F O R M AT I O N : S A M P L E N U M B E R : 8 T I 5 - 2 5 4 T 5 - T BW- 1 2 0 V- E B T 1- U P L Length Blank=4' Length 8T=8' Length Series I5=T5 Industrial I8=T8 Industrial Mounting Arrangement Blank=Stand Alone R=Continuous Row Mount No. of Lamps 2=2 Lamps (T5) 3=3 Lamps (T5, T8) 4=4 Lamps (T5) T2=2 Tandem Lamps (Biax) T3=3 Tandem Lamps (Biax) T4=4 Tandem Lamps (Biax) Lamp Type I5 28T5=T5 Std (4') Lamps 54T5=T5HO (4') Lamps BX40=40W Biax Lamps BX50=50W Biax Lamps BX55=55W Biax Lamps Wireguard Blank=No Guard WG=Heavy Duty Wireguard Lamp Type I8 32=32W T8 (48") Distribution Optic Blank=Aisle G=General Downlight Optic Blank=Open TBW=Thin White Baffle FL=Frosted Acrylic Lens & Frame ASY=Asymmetric Directional Louver (1) Voltage UNV=Universal 120/277 Voltage (1) UNC=Universal 347/480 Voltage (T5 linear only)(1) 120V=120 Volt 277V=277 Volt 347V=347 Volt Options GL=Single Element Fuse GM=Double Element Fuse Lamps - for lamps installed Emergency - for EM installed NOTES: Not available when specifying emergencies, voltage must be specific. For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. Ballast Type Options (See Options & EB5 =T5 Biax Electronic Instant Start. Accessories Total Harmonic Distortion < 20% Pages 13, 14) No. of Ballast 1, 2 or 3 TEB5 =T5 Biax Electronic Instant Start. Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 EBT =T5 Linear Electronic Program Rapid Start. Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 LEOC8 =T8 Magnetic Energy Saving ER8 =T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 EB8 =T8 Electronic Instant Start. Total Harmonic Distortion < 20% No. of Ballast 1, 2 or 3 EB8 /PLUS = T8 Electronic Instant Start. High Ballast Factor >1.13. Total Harmonic Distortion < 20% No. of Ballast 1, 2 or 3 TEB8 =T8 Electronic Instant Start. Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 DIM=Dimming DLS=Digital Lighting System Dimming Packaging U=Unit Pack hb H B O R D E R I N G I N F O R M AT I O N : S A M P L E N U M B E R : H B - R - 2 3 2 - A- 1 2 0 V- E B 8 1 Width Blank=15" 2=24" Series HB=High Bay Mounting Arrangement Blank=Stand Alone R=Continuous Row Mount No. of Lamps 2=2 Lamps (5) 3=3 Lamps (5) 4=4 Lamps 6=6 Lamps (6) Lamp Type BX40=40W Biax Lamps (24") (3) BX55=55W Biax Lamps (24") (3) 32=32W T8 Lamps (48") 28T5=28W T5 Lamps (48") 54T5=T5HO Lamps (48") Distribution Optic Blank=Aisle G=General (1) NOTES: Products also available in non-US voltages and frequencies for (2) international markets. Not available when specifying emergencies, voltage (3) (4) must be specific. Biax available in 6-lamp only. Not available for biax (5) (6) model. 15" width only. 24" width only 15 For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. Downlight Optic A=Prismatic Acrylic Lens & Doorframe WG=Wireguard & Doorframe(4) A/WG=Acrylic Lens, Wireguard & Doorframe(4) CL=Clear Acrylic Lens & Doorframe SWG=Field Installable Wireguard Voltage (1) UNV=Universal 120/277 Voltage (2) UNC=Universal 347/480 Voltage (T5 linear only) 120V=120 Volt 277V=277 Volt 347V=347 Volt Options GL=Single Element Fuse GM=Double Element Fuse Lamps - Lamps installed Emergency - EM installed Options Ballast Type (1) (See Options EB8 =T8 Electronic Instant Start. & Accessories Total Harmonic Distortion < 20% Pages 13, 14) No. of Ballast 1, 2 or 3 EB8 /PLUS= T8 Electronic Instant Start. High Ballast Factor >1.13. Total No. of Harmonic Distortion < 20% Ballast 1, 2 or 3 ER8 =T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 TEB8 =T8 Electronic Instant Start. Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 EB5 =T5 Biax Electronic Instant Start. Total Harmonic Distortion < 20% No. of Ballast 2 TEB5 =T5 Biax Electronic Instant Start. Total Harmonic Distortion < 10% No. of Ballast 2 EBT =T5 Linear Electronic Program Rapid Start Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 DIM=Dimming DLS=Digital Lighting System Dimming Packaging U=Unit Pack hbo/hbot/ha H B O / H B O T / H A O R D E R I N G I N F O R M AT I O N : S A M P L E N U M B E R : 3 H B O - 8 3 2 - 1 2 0 V- E B 8 2 Width Blank=15" wide 2=24" wide 3=32" wide Series HBO=High Bay Open Version HBOT=High Bay Open Top Version HA=High Ambient No. of Lamps 4=4 Lamps 6=6 Lamps 8=8 Lamps Wattage (Length) 32=32W T8 (48") Lamps 28T5=28W T5 (48") Lamps 54T5=54W T5HO (48") Lamps Voltage (1) UNV=Universal 120/277 Voltage (2) UNC=Universal 347/480 Voltage (T5 linear only) (2) 120V=120 Volt 277V=277 Volt 347V=347 Volt Options Ballast Type (1) (See Options & EB8 =T8 Electronic Instant Start. Accessories Total Harmonic Distortion < 20% Pages 13, 14) No. of Ballast 1, 2 or 3 EB8 /PLUS= T8 Electronic Instant Start. High Ballast Factor >1.13. Total No. of Harmonic Distortion < 20% Ballast 1, 2 or 3 Options GL=Single Element Fuse GM=Double Element Fuse Lamps - Lamps installed Emergency - EM installed ER8 =T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 TEB8 =T8 Electronic Instant Start. Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 EBT =T5 Linear Electronic Program Rapid Start. Total Harmonic Distortion < 10% No. of Ballast 1 or 2 DIM=Dimming DLS=Digital Lighting System Dimming Distribution Optic Blank=Aisle (Aluminum) G=General (White Painted) (1) NOTES: Products also available in non-US voltages and frequencies for international markets. specifying emergencies, voltage must be specific. (2) Not available when Packaging U=Unit Pack For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. mb M B O R D E R I N G I N F O R M AT I O N : S A M P L E N U M B E R : M B - 1 5 4 T 5 - 1 2 0 V- E B T 1 Tandem Blank=4' Length 8T=8' Length Lamp Types 54T5=54W T5/HO (4' Unit) 32=32WT8 Voltage UNV=Universal Voltage 120-277 Series MB= T5 Micro-Bay Reflector FB=Focus Beam TB=Task Beam NB=Normal Beam Options Number of Lamps (Not included) 1=1 Lamp 2=2 Lamps NOTES: (1) Products also available in non-US voltages and frequencies for international markets. For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. Ballast Type (1) EB8 =T8 Electronic Instant Start. Total Harmonic Distortion < 20% No. of Ballast 1, 2 or 3 EB8 /PLUS= T8 Electronic Instant Start. High Ballast Factor >1.13. Total No. of Harmonic Distortion < 20% Ballast 1, 2 or 3 Options (See Options & Accessories Pages 13, 14) Packaging U=Unit Pack PAL=Pallet Pack ER8 =T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 TEB8 =T8 Electronic Instant Start. Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 EBT =T5 Linear Electronic Program Rapid Start. Total Harmonic Distortion < 10% No. of Ballast 1 or 2 DIM=Dimming DLS=Digital Lighting System Dimming 16 2hbg 2 H B G O R D E R I N G I N F O R M AT I O N : S A M P L E N U M B E R : 2 H B G - 6 5 4 T 5 - A- U N V- E B T 2 - U Downlight Optic Blank=Open A=Prismatic Acrylic Lens & Aluminum Doorframe CL=Clear Acrylic Lens & Aluminum Doorframe Width 2=24" Series HB=High Bay Trim Type G=Grid/Lay-in (Standard) F=Flange Trim Options (See Options & Accessories Pages 13, 14) Voltage (1) UNV=Universal 120/277 Voltage UNC=Universal 347/480 Voltage (T5 linear only) 120V=120 Volt 277V=277 Volt 347V=347 Volt No. of Lamps 6=6 Lamps Lamp Type 32=32W T8 Lamps (48") 28T5=28W T5 Lamps (48") 54T5=T5HO Lamps (48") Options GL=Single Element Fuse GM=Double Element Fuse Lamps - Lamps installed Emergency (T8 only) - EM installed,(1) Distribution Optic Blank=Aisle G=General (1) NOTES: Products also available in non-US voltages and frequencies for international (2) markets. Not available when specifying emergencies, voltage must be specific. Ballast Type (1) EB8 =T8 Electronic Instant Start. Total Harmonic Distortion < 20% No. of Ballast 1, 2 or 3 EB8 /PLUS= T8 Electronic Instant Start. High Ballast Factor >1.13. Total No. of Harmonic Distortion < 20% Ballast 1, 2 or 3 ER8 =T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 TEB8 =T8 Electronic Instant Start. Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 EBT =T5 Linear Electronic Program Rapid Start. Total Harmonic Distortion < 10% No. of Ballast 1 or 2 Packaging U=Unit Pack PAL=Job Pack, out of carton PALC=Job Pack, in carton For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. 2hbhd 2 H B H D O R D E R I N G I N F O R M AT I O N : S A M P L E N U M B E R : 2 H B H D - 6 5 4 T 5 - A- U N V- E B T 2 Width 2=24" Series HBHD=High Bay Hose Down No. of Lamps 4=4 Lamps 6=6 Lamps Lamp Type 32=32W T8 Lamps (48") 28T5=28W T5 Lamps (48") 54T5=T5HO Lamps (48") Distribution Optic Blank=Aisle G=General (1) NOTES: Products also available in non-US voltages and frequencies for (2) international markets. Not available when specifying emergencies, voltage (4) must be specific. Use with general distribution reflector. For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. 17 Downlight Optic Blank=Open A=Prismatic Acrylic Lens & Doorframe(4) CL=Clear Acrylic Lens & Doorframe Voltage (1) UNV=Universal 120/277 Voltage(2) UNC=Universal 347/480 Voltage (T5 linear only) 120V=120 Volt 277V=277 Volt 347V=347 Volt Options GL=Single Element Fuse GM=Double Element Fuse Lamps - Lamps installed Emergency - EM installed Options Ballast Type (1) (See Options EB8 =T8 Electronic Instant Start. & Accessories Total Harmonic Distortion < 20% Pages 13, 14) No. of Ballast 1, 2 or 3 EB8 /PLUS= T8 Electronic Instant Start. High Ballast Factor >1.13. Total No. of Harmonic Distortion < 20% Ballast 1, 2 or 3 ER8 =T8 Electronic Program Rapid Start. Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 TEB8 =T8 Electronic Instant Start. Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 EBT =T5 Linear Electronic Program Rapid Start. Total Harmonic Distortion < 10% No. of Ballast 1, 2 or 3 DIM=Dimming DLS=Digital Lighting System Dimming Packaging U=Unit Pack PAL=Palletized Out of Carton Ideal Solution For: Retail – maximize energy savings while delivering excellent lumens per watt and consistent color throughout the store. Warehouses & Manufacturing Facilities– excellent lumen maintenance prevents light levels from dropping to unsafe or unacceptable levels and higher lumens per watt lower energy costs. The use of occupancy sensors further reduce energy costs. Gymnasiums, Cafeterias, Auditoriums– no need to wait for lights to turn on with the instant on feature, plus occupancy sensors offer additional energy savings. F-Bay Offers the Following Advantages: • Superior solution with 50% energy savings H.I.D. • Excellent optics with comparable lumen output – Specular reflectors ideal for Hi-Bay applications – White reflectors ideal for Low-Bay applications – 8% Uplight option provides ceiling uniformity A Visible • Instant On/Off allows for use of Occupancy and Sensors to optimize energy savings Money Saving • Multiple mounting options offer flexibility and Difference reduce labor costs • Superior lumen maintenance and lamp life Combine these benefits with Cooper Lighting’s unparalleled product breadth and experience and you have the best fluorescent high bay solution in the industry working for you. F-BAY Cooper Lighting is your source for fluorescent high bay solutions for every application in commercial, industrial and institutional settings. 18 Customer First Center 1121 Highway 74 South Peachtree City, Georgia 30269 770 486 4800 Fax 770 486 4801 Domestic Facilities, USA Cranbury, New Jersey Elk Grove Village, Illinois Irving, Texas Ontario, California Peachtree City, Georgia International Sales, USA Peachtree City, Georgia Canada Cooper Lighting 5925 McLaughlin Road Mississauga, Ontario L5R 1B8 905 507 4000 FAX 905 568 7049 The Cooper Lighting Family Halo Cooper Lighting - Metalux Cooper Lighting - Lumark Cooper Lighting - Sure-Lites Neo-Ray Corelite Portfolio Iris Shaper Lumière Invue McGraw-Edison Fail-Safe MWS DLS RSA Domestic Facilities, Canada Calgary, Alberta Chomedey, Laval P.Q. Cooper Lighting, Inc. All rights reserved Printed in USA Dimensions and specifications are subject to change without notice. www.cooperlighting.com ADF060565