Trayer Engineering Corporation Product Line Overview Trayer Engineering Corporation Manufacturers of Quality Electrical Distribution Switchgear since 1962 Product Line Overview Trayer Engineering: Electrical Pioneer, Committed to Excellence .............................. 2 Trayer’s Commitment to Excellent Customer Service .......................... 2 Verified by Design: Simple and Reliable ........ 2 Submersible & Vaultmount Automation........ 3 Padmount Automation Auto Transfer & SCADA ................................. 4 Submersible Switchgear .............................. 5-6 Padmount Switchgear Single-Sided .............. 7 Padmount Switchgear Double-Sided ............ 8 Submersible Features & Control Options ...... 9 Padmount Features & Control Options ........ 10 Trayer Engineering Corporation 898 Pennsylvania Avenue • San Francisco • California • 94107 (415) 285-7770 • (800) 377-1774 • Fax (415) 285-0883 • sales@trayer.com • www.trayer.com Trayer Engineering: Electrical Pioneer, Committed to Excellence Founded in 1962, Trayer Engineering Corporation has been a pioneer in the design and manufacture of maintenance-free vacuum switchgear for electrical distribution systems. With experience and patents using vacuum technology since 1970, Trayer is the vacuum switchgear specialist. Trayer serves a variety of worldwide markets. Its list of users range from utilities to municipalities, government installations, to college and universities, along with a wide array of industrial customers. An ISO 9001:2008 certified company, Trayer stands alone in its commitment to excellence in design, quality workmanship, dependability and unparalleled customer service. For additional product information, technical specifications, or to discuss your specific switchgear requirements, please contact Trayer Engineering Corporation directly or through your local Trayer representative. Trayer’s Commitment to Excellent Customer Service Trayer enjoys working with all of our customers to provide the right solutions for their Distribution Automation needs. Whether you are installing a SCADA system, high speed Automatic Transfer System, or just preparing for the future, Trayer is here to help provide the safest, long lasting, field- proven, maintenance-free switchgear designs. The flexibility of Trayer’s modular designs allows customers to provide input into the design and choice of controls for their Trayer distribution switchgear. Trayer’s single or three-phase internally mounted and fused potential transformers provide a self-powered automation switchgear solution. These solutions include current and potential transformers with the accuracy to do most power calculations. Trayer has been providing quality automated switchgear solutions for 40 years. Let Trayer help you with your next switchgear project. position. There are provisions to lock the device in both the “CLOSED” or “OPEN” position and there is an interlock that must be opened before you can place the device into the “GROUND” position (see below). is provided mechanically by a yellow indicating rod attached to the trip bar of the VFI mechanism inside the tank. This mechanical “trip indicator” is viewed through a clear sight glass on the face of the switch tank near the operating handle. When the mechanism is tripped, the VFI handle stays in the CLOSED position and the yellow Trip Indicator rod (see below) protrudes from the tank and is visible inside the clear sight glass. For secondary TRIP indication, the customer can then look to the relay to see the faulted phase. To reset the mechanism after it has been tripped, the operator simply pulls the operating handle to the OPEN position. The mechanism is responsible for resetting itself. No additional cocking or verification of the OPEN / Reset position is required. Verified by Design: Simple and Reliable Trayer has been using vacuum technology for more than 40 years and has integrated decades of experience into the basic design of our switchgear. Trayer’s operating handles on the vacuum loadbreak switch and vacuum fault interrupter mechanisms verify OPEN and CLOSED positions by design. Trayer has developed fundamental design elements in all of our products to increase the reliability of our switchgear and simplify their operation. Vacuum technology does not provide a visible open since the contacts are sealed within the envelope of the vacuum enclosure. Some manufacturers attempt to resolve this “Visible Open” issue with the provision of a pointer or semaphore to indicate contact separation, yet no “Open” contacts can actually be seen. Trayer can provide a truly visible “Open” set of contacts by incorporating Trayer’s patented Tri-Phase Two Position Visible Disconnect Window Visible Disconnect device. The contacts on the Tri-Phase Visible Disconnect device are viewed through a window on the surface of the tank and are clearly visible (see below). The visible disconnect device is a second loadbreak rated switch in series with either the vacuum loadbreak switch or vacuum fault interrupter. Building on the simplicity of the original Trayer designs and patents, Trayer now incorporates two mechanically interlocked operating handles so that a line crew must break the load with either a vacuum loadbreak switch or vacuum fault interrupter before gaining access to the second operating handle for the visible disconnect device (see below). Trayer has expanded this optional technology to now include an internal ground position. There are two interlocking features on the visible disconnect with GROUND Patented Tri-Phase Interlocking Handles The Trayer Vacuum Fault Interrupter (VFI) operating handle operates in the same way as the loadbreak switch operating handle. Both mechanisms’ operating handles have two positions, OPEN and CLOSED. When in the OPEN position, the handle is away from the switch tank. When CLOSED, the handle is parallel with the face of the switch tank. Tripping power for the VFI mechanism is supplied by a potential transformer on Trayer’s 3000 series VFIs and by internal current transformers on Trayer’s 4000 series VFIs. The primary TRIP indication of the VFI mechanism Tri-Phase Visible Disconnect with Ground Position Mechanical VFI Trip Indicator 2 Submersible & Vaultmount Automation Submersible Switch with Visible Disconnects & Motopaks }CAT#102VD2CM2-201(2) 3-Way Side-Mounted Vaultmount with Motopaks }CAT#113CGM83 3000 Series Vaultmount with SEL Relay and Motopaks }CAT#3112-3FVD3M2 Trayer has been providing Distribution Automation solutions since 1971. Trayer’s original submersible vacuum loadbreak switches were designed with automation in mind. These round compact units were set on a mild steel, hot-dipped galvanized stand with provisions to mount the motor operators onto the switch and stand assembly. The Trayer submersible “Motopak” is constructed from 304 stainless steel and has provided nearly 40 years of field-proven operational service. These Motopaks are fitted with gear driven motors and have been successfully installed in some of the world’s harshest environments. Submersible and Vaultmount applications come with many different requirements to get the job done. Trayer provides many solutions to fit the needs of our customers. Side-mounted “saddle-type” stands allow customers to use submersible traditionally top operable switches as vault style switchgear. Stands are sold separately and several are prepared to add on motor operator mounting brackets. For side-mounted vault style applications, Trayer also offers two sling rotation “knobs.” These knobs are welded to the switch tank and assist with lifting a unit off its pallet. Once in the air the construction crews can rotate the switch in the sling onto its side to be placed in to the “saddle” stand. Trayer’s automation products can be fitted to every vacuum loadbreak switch and vacuum fault interrupter combination. Vaultmounted designs can be side mounted or bottom mounted to fit the application. On rectangular switchgear designs, Motopaks can be mounted directly to the tank surface. Customers must order optional mounting provisions at time of construction. If the passageway for getting the switchgear into the vault is tight, the customer can order bolt-on automation accessories that allow the switchgear to pass through the opening to be assembled in place. Dry Vault SCADA Application with Seismic Rated Stand }CAT#3115-0CM For dry vault applications, Trayer can provide a lower cost automation solution by using padmount style water resistant motor operators. Simply put, we take a single-sided padmount design, remove the high voltage enclosure, and build a stand to replace the base. In this photo, Trayer has responded to another of our customer’s requests by designing a shroud to cover the motor operators and protect the face of the switchgear during transportation and storage before installation. Included with the switch is a seismic-rated stand and provisions to secure the unit to the vault wall. 3 SCADA RTUs and Over-current Protection Trayer provides automated switchgear solutions in Padmount, Vaultmount and Submersible designs. For consistency and reliability, we manufacturer our own submersible and padmount low voltage control cabinets. Trayer’s automation solutions are self-powered from internally mounted and fused potential transformers. Single-phase or optional three-phase PTs are available for control power, voltage monitoring and power calculations. Extreme Reliability Solutions Trayer’s experience in Distribution Automation has been field-proven for nearly 40 years. Trayer has provided many automated solutions for some very challenging applications. Whether your project requires Differential or Directional relaying, Primary Cable or Primary Loop Protection, High Speed 10 Cycle Auto Transfer, SCADA control and Communication, Main-Tie-Main solutions between multiple switchgear units, or applying Distribution Products for use as mini substations, Trayer has the solution. Padmount Automation - Auto Transfer & SCADA 10 Cycle - Auto Transfer System, Single-Sided SCADA }CAT# 3800C9VD4 - ATS Trayer’s premier 10 cycle Automatic Transfer System (ATS) is a step above the rest. Trayer has designed a padmounted high speed auto transfer system for your most critical loads. This ATS switchgear design includes six internally mounted and fused potential transformers, three on each of the two incoming source ways. The six voltage inputs can be read locally or through SCADA, and are accurate for calculations. Two 600 Amp VFI tap ways provide the over-current and fault protection for your loads. CT current information can be read locally in the control or through SCADA. The above unit includes a newly redesigned control cabinet to withstand the harshest coastal applications. Auto Transfer System - Double-Sided for Replacement of Existing Equipment }CAT# 3805A13VD3 - ATS Trayer’s Automatic Transfer Systems offer very reliable solutions for your most critical customers. This three source Auto Transfer System utilizes two utility feeds and a standby generator to supply power to this customer’s critical load. A three source vacuum loadbreak switching scheme combines Trayer’s proven technology with today’s advancements in automation, communication and relaying. Trayer has programmed the SEL 451 automation platform to provide the auto transfer logic, motor control, and fault blocking. This particular design uses three internally mounted and fused protected potential transformers to provide control power from the incoming utility and generator sources. 3000 Series Single-Sided SCADA Switchgear with RTU }CAT# 3810C9VD4M6 Auto Transfer System - Single-Sided with Optional External PT Power }CAT# G3800C9M3- ATS Trayer’s switchgear, designed for remote Supervisory Control and Data Acquisition (SCADA) applications, is available in many shapes, sizes, and control options. Trayer’s standard switchgear designs are coupled with customer specified relays and remote terminal units (RTU) to complete automation packages for our customers. Trayer uses 3000 Series VFIs built on nearly 20 years of field-proven Trayer VFI designs and incorporate the latest advancements in vacuum technology and microprocessor-based relay and communication controls. The 304 stainless steel, single-side access, Auto Transfer System combines vacuum loadbreak switching and vacuum fault interrupter protection to create a powerful automatic transfer and over-current protection system. Trayer uses the SEL 451 automation platform and dual channel over-current relay to provide the auto transfer logic, motor control, over-current protection and fault interruption. This particular design uses externally mounted potential transformers connected to the incoming ways through a fused 200 Amp interface to provide control power. G3805/G3815 Double-Sided SF6 Insulated SCADA 3000 Series VFI }CAT# G3805C9VDG4 800/810 Liquid & G800/G810 SF6 Insulated Single-Sided Switch Only }CAT# 800C10VD4M30 Trayer’s double-side, SF6-insulated 3805/3815 series vacuum fault interrupters combine vacuum loadbreak switching and vacuum fault interrupter and relay protection in standard padmount configurations and designs to replace original equipment on their existing foundations. Built on nearly 20 years of field-proven and patented VFI designs, this equipment incorporates the latest advancements in vacuum technology and microprocessor-based relay controls. Optional Tri-phase Visible Disconnect with Ground Position is available on vacuum loadbreak switch and vacuum fault interrupter ways. The maintenance free, 304 stainless steel Trayer 8_0 Series switchgear represents our single-side access padmounted switch-only units. This unit is designed with “to the left” slanted bushings and shown with the optional tall high voltage enclosure and mounted motor operators. Trayer can easily modify most designs to match your existing bushing layouts. The vacuum loadbreak switch mechanisms are 600 Amp rated and provide 10,000 maintenance free operations in liquid and 3,000 operations in SF6; perfect for SCADA applications. 4 Submersible Switchgear Oil Fused Cut-out Replacement VFI }CAT#4111-0AM2 Trayer’s new single-phase Oil Fused Cut-out replacement design is 40% smaller than our previous model. This 27kV – 600Amp - 12.5kA vacuum fault interrupter has been redesigned to provide the line crews with more space in their vaults or manholes. The unit is constructed from 304 stainless steel and comes with a CT powered submersible over-current relay. This unit stands out by including a “truly visible” single-phase visible disconnect device in series with the vacuum fault interrupter. As with all Trayer visible disconnect devices, this visible OPEN contact is an “isolation” point and is safe to use for testing and grounding of cables attached to the equipment. Several mounting options are available. 4-Way Wet Well with Visible Disconnect }CAT#102BSF2BVD2 If you are looking for a low cost reliable solution for underground protection look to Trayer’s 15kV, 25kV, and 35kV submersible switch and fuse gear. Trayer’s Universal Fuse Well has been successfully providing protection to underground circuits for over 30 years. This Trayer custom design integrates the 200 Amp bushing into the fuse cap, making it nearly “fool proof ” to pull a fuse under load. The line crew will remove the 200 Amp loadbreak elbow and park it before gaining access to remove the fuse. After replacing the fuse and installing it into the switch tank, the line crew will then use the rated 200 Amp elbow to energize the circuit. It’s safe and cost effective. Full range current limiting fuses are available up to 200 amps at 15kV. 5 Liquid Insulated Submersible 15, 25 and 35 kV Switch Only }CAT#102C 3-Way Submersible Switchgear with Visible Disconnect }CAT#102SCM1 Trayer’s submersible switchgear provides reliable switching solutions in the harshest underground environments. These two, three and four way switches are constructed from 304 stainless steel and are round and sized to pass through common manhole openings. The vacuum loadbreak switch mechanisms are 600 Amp rated with 10,000 mechanical operations in liquid dielectric and 3,000 operations in SF6. Customers can order their equipment with either 600 Amp bushings or 200 Amp bushing wells. These switches have been installed and operating in some of the harshest environments since 1970. Trayer’s round submersible switchgear designs are also available with Trayer’s patented TriPhase Visible Disconnects. These submersible designs come with submersible covers for the windows to keep dirt and debris from building up and blocking the view of the open contacts through the visible disconnect window. The visible disconnects in the OPEN position provide a safe working isolation point for testing and grounding of 600 Amp cables without removing them from the bushings. 3000 Series SF6 Insulated Vacuum Fault Interrupter Protection }CAT#G3102-1CGM1 4000 Series Submersible with Ganged VFI Mechanisms }CAT#4101-2C Trayer’s 3000 series submersible 15kV and 25kV Vacuum Fault Interrupter switchgear offers compact designs for various underground applications. This 34-½ inch compact three way SF6 insulated model includes a 600 Amp switch and two 600 Amp VFI protected ways. Like most of Trayer’s 3000 series VFIs, this unit is designed with CTs and a PT mounted inside the switch tank. The SEL 501-2 over-current relay is located in a 304 stainless steel submersible enclosure to be mounted on the vault wall. Trayer manufactures the low voltage enclosures and provides gas-blocked submersible connectors and cabling for easy installation. Trayer’s 4000 series submersible 15kV and 25kV Vacuum Fault Interrupter protected switchgear is a CT powered single-phase trip VFI design. This 34-½ inch compact three way design helps to increase customer reliability numbers by being able to trip either single or three-phase based on the relay and settings. This unit is shown with optional rope operator provisions and circuit tag holders. Submersible Switchgear 4-Way Wet Well Fuseholder }CAT#102S2BSF2BM3 4-Way Switch & Fuse }CAT#104BSF2BM18 4000 Series 4-Way VFI Protection }CAT#G4102-2BM1 Trayer’s 15kV, 25kV, and 35kV submersible switch and fuse switchgear designs are easily modified to meet our customer’s growing underground needs. This four way switchgear design, with two switched ways and two fuse protected ways, was an answer to a customer’s request to have their submersible equipment set up more like their double sided Padmount “9” configuration, with loadbreak switches on one side and fuse protected ways on the other side. It also made it easier for their crews to get access to the equipment from the open working sides of their pop-up cover vault doors. This unit is shown with optional Tri-Phase Visible Disconnects and window covers. Full range current limiting fuses are available up to 200 Amps at 15kV. This Trayer submersible switch and Universal Fuse Well unit includes three-phase vacuum loadbreak switches in series with Trayer’s Universal Fuse Wells permitting three-phase OPEN and CLOSE of the circuit. Full range current limiting fuses provide a safe, fast interrupting and effective way to protect your underground circuits. Square and rectangular designs are available to fit most vault openings. Trayer’s 4000 Series 15kV and 25kV, single phase trip, submersible VFIs offer the ease of resetting a vacuum fault interrupter instead of replacing a fuse. These 4000 Series products are available in several configurations and footprints. Trayer supplies submersible rated, CT powered, over-current relays with 24 of the most commonly used fuse and relay curves programmed into the relay. These relays are “hot swappable” due to Trayer providing an automatic internal CT shorting circuit inside the switch tank. This permits customers the opportunity to test, replace, or upgrade their relays in the future without de-energizing the switchgear. 3-Way Submersible VFI Protcetion }CAT#3111-2BM8 4-Way Submersible Switchgear with Optional Visible Disconnects }CAT#104CVD4M1 3000 Series 4-Way VFI Protection with Visible Disconnects }CAT#G3102-2BVDG4M1 Trayer’s 3000 series 15kV and 25kV Vacuum Loadbreak Switch (VLS) and Vacuum Fault Interrupter (VFI) mechanism’s modular designs make modifications easy. Featured here is a unit with four ways and each way includes the patented Tri-phase Visible Disconnect devices in series. This rectangular design allows for easy replacement of any loadbreak switch with a 3000 series VFI mechanism. This design is available up to 6 ways with any combination and placement of switches and interrupters. Trayer offers a Tri-phase Visible Disconnect device with an optional internal ground position. This three position (CLOSE/OPEN/GROUND) mechanism is available in SF6 and liquid insulated equipment. Like its two position (CLOSE/ OPEN) counterpart, this three position mechanism’s operating handle interlocks with either the vacuum loadbreak switch or 3000 series vacuum fault interrupter handles, so that all load and fault interruption is performed in the vacuum contact and not in the dielectric. A larger viewing window is provided so that line crews can clearly see the contacts in all three positions. Trayer’s 3000 series 15kV and 25kV Submersible Vacuum Fault Interrupter switchgear is a smaller design of Trayer’s original 2000 series VFI patented in 1979. This smaller VFI frame allows for compact vacuum loadbreak switch and VFI designs to provide three-phase VFI protection in the distribution circuit. The 3000 series products come standard with substation class SEL over-current relays on board. Trayer mounts all the current transformers and potential transformers inside the tank. All wire penetrations are O-ring sealed into the low voltage control cabinet welded onto the switch tank. A fiber optic communication cable is supplied so that the relay technician doesn’t need to get into the vault to download information or change settings. 6 Padmount Switchgear Single-Sided 4800 & 4810 Series: Single-Phase 4000 Series VFI }CAT# 4800B1 4800 & 4810 Series: Single-Phase 4000 Series VFI }CAT# 4810C1VDS3 4800/4810 Liquid & G4800/G4810 SF6 Insulated Single-Phase 4000 Series VFI }CAT# G4800A89 800/810 Liquid & G800/G810 SF6 Insulated Switch Only }CAT# 810C10VD4M33 800/810 Liquid & G800/G810 SF6 Insulated 15 & 25kV Switch Only }CAT# 800C27VD5M1 G3800/G3810 SF6 Insulated 15 & 25kV, Three-Phase VFI }CAT# G3800B82 The Trayer 4000 Series single-side access singlephase vacuum fault interrupter was introduced in 2004. The single-phase VFIs and accompanying CT powered single-phase trip or three-phase trip relays provide multiple protection options for our customers. This padmount two way single-phase unit can be used to replace cable junctions and protect single-phase underground tap circuits. Many design options are available. The maintenance-free, 304 stainless steel Trayer 8_0 Series switchgear represents our single-side access padmounted switch-only units. This unit is shown with Trayer’s cabinet style enclosure and “to the right” slanted bushings that pattern some older style switchgear. The vacuum loadbreak switch mechanisms are 600 Amp rated and provide 10,000 operations in liquid and 3,000 operations in SF6. Trayer’s patented Tri-Phase Visible Disconnect devices with interlocking handle designs are optional on all switched ways. The visible disconnect displays a truly visible “OPEN” set of contacts and provides a safe “isolation point” to test cables without the need to remove them. 7 The Trayer 4000 Series single-side access liquid insulated single-phase vacuum fault interrupter was introduced in 2004. The single-phase VFIs and accompanying CT powered or SEL singlephase trip relays provide multiple protection options for our customers. These 27kV rated devices can be used for 600 Amp load switching as well as 600 Amp VFI protection. Customers can order their 4000 series VFIs with either 600 Amp bushings or 200 Amp bushing wells. Trayer also offers single-phase 600 Amp visible disconnect devices. The maintenance-free, 304 stainless steel Trayer 8_0 Series switchgear represents our single-side access padmounted switch-only units. Trayer’s single side access 800/810 and G800/G810 Series units are modular in design and available up to 8 ways. These units are available with bushings that slant to either the left (as shown) or to the right. Trayer’s patented Tri-Phase Visible Disconnect devices can be lowered to a position beside the bushings providing an even lower switch profile. The Trayer 4000 Series single-side access liquid or SF6 insulated single-phase vacuum fault interrupter was introduced in 2004. The singlephase VFIs and accompanying CT powered single-phase or three-phase trip relays provide many protection options for our customers. These 27kV rated devices can be used for 600 Amp load switching as well as 600 Amp VFI protection. Customers can order their 4000 series VFIs with either 600 Amp bushings or 200 Amp bushing wells. Custom designs are available. This design is to replace another manufacture’s four way padmount unit by matching the size and bushing layout. The 304 stainless steel G38_0 Series combines vacuum load-break switching and vacuum fault interrupter protection in standard configurations and design to replace original equipment on their existing foundations. Trayer’s 3000 Series Vacuum Fault Interrupters introduced in 1999 are based on our original 2000 Series VFI design patented in 1980. The 3000 Series VFI incorporates the latest advancements in vacuum technology and microprocessor-based relay controls. Optional Tri-Phase 3 position Visible Disconnect with Ground is available on vacuum loadbreak switch and vacuum fault interrupter ways. These units are available with optional tall high voltage enclosures for SCADA motor operators. Padmount Switchgear Double-Sided 805/815 Liquid & G805/G815 SF6 Insulated Switch Only }CAT# 805C10VD4 802, 812 & 822 Liquid Insulated Switch with Fuse Protection }CAT# 812B9 3000 Series Liquid Insulated VFI }CAT# 3815B9 3805/3815 Liquid Insulated Three-Phase 3000 Series VFI }CAT# 3805E82VD6M1 4000 Series VFIs with Single-Phase Visible Disconnects }CAT# 4805C9VD2S6 4000 Series Padmount with Ganged VFI Mechanisms }CAT# 4815C9 The maintenance-free, 304 stainless steel, Trayer 8_5 Series represents our double-side access padmounted switch-only units. The footprint and horizontal bushing designs are sized to make an easy retrofit conversion from live front air-insulated switchgear to sealed dead front using the existing foundation. The vacuum loadbreak switch mechanisms are 600 Amp rated. Every switched way comes prepared with motor mounting provisions for SCADA motor operators. These units can be ordered with low profile bases and lift up hoods or with cabinet front high voltage enclosures. The maintenance-free, 304 stainless steel Trayer 38_5 Series combine vacuum loadbreak switching and vacuum fault interrupter and relay protection in standard configurations and design to replace original equipment on their existing foundations. This modular, double-sided, 6 way design allows for many combinations of loadbreak switch and vacuum fault interrupter configurations. Cabinet style enclosures with lift up lids for these longer units reduce the weight of “old style” hoods. The horizontal operating handles are set up to add SCADA motor operators in the future. Optional Tri-phase Visible Disconnect is available on both vacuum loadbreak switch and vacuum fault interrupter ways. The 304 stainless steel Trayer 802, 812, and 822 Series are the backbone of Trayer’s Padmount line and have been field proven for over 35 years. These 15kV, 25kV and 35kV class switchgear offer 600 Amp vacuum loadbreak switches with full-range, current-limiting fuse protection. Featured are Trayer’s Universal Fuse Wells which accommodate liquid immersed current limiting fuses up to 200 Amps at 15kV. The Trayer Universal Fuse Well is designed with safety in mind. Trayer’s design integrates the bushing well into the fuse cap assuring that a lineman never makes and breaks load with the fuse. This “fool proof ” design requires that the cable is removed prior to getting access to the fuse cap. Trayer’s 4000 Series offers the same footprint and bushing layout design for easy retrofit applications. This product line differs from the 3805 Series by adding the versatility of single-phase trip 4000 Series vacuum fault interrupters. The single-phase VFIs and accompanying single-phase or threephase trip relays are CT-powered from internallymounted current transformers. They only require a minimum of 15 amps per three-phase way in order to stay active. If there is a complete loss of power, the relay restores and can trip the VFI within as little as 10 milliseconds. Trayer offers singlephase visible disconnects in series with 4000 Series VFIs permitting customers to leave their 600 Amp cables attached while testing and grounding. Double-sided, 4 way designs are available in standard 9, 11, and 12 configurations to upgrade or replace original fused equipment on their existing foundations. A typical 12 configuration is designed with a 600 Amp loadbreak switch IN, two 200 Amp VFI load tap ways and a 600 Amp three phase VFI OUT. The 600 Amp VFI provides primary cable fault protection and interruption, isolating a fault mid circuit. This increases reliability by keeping more of your customers powered during a primary cable fault. Optional Tri-phase Visible Disconnect devices are available on both the vacuum loadbreak switch and vacuum fault interrupter mechanisms. The Trayer 48_5 Series offers the same footprint and bushing layout design as the 8_5 and 38_5 Series units offering easy retrofit applications of existing switchgear. There are many designs available to replace live front air-insulated switchgear to old oil switches. This product line differs from the 38_5 Series by adding the versatility of single-phase trip 4000 Series vacuum fault interrupters and CT powered over-current relays. This particular switch design offers single or three-phase trip with three-phase Open/Reset/Close. 8 Submersible Features & Control Options 9 Submersible RTU Control Trident Submersible 3-Phase OPEN/CLOSE Shotgun Adapter Remote Submersible Relay Enclosure Fiber Optic Communication Universal Fuseholder - Cap Guides & Quick Close Clamps Bolt on Motor Operator Mounting Bracket and Stand 360o Open Rope Operator with Upper Stanchion Rings 360o Rope Close Operator Tank Ring External Ground & Relay Cut Out Switch Slide Bar Interlock for Drywell Fuses CT Powered Submersible Relay Submersible Motopak Padmount Features & Control Options Visible Disconnect with Ground Position Drain Valve with Sampler Internal Potential Transformers Single-Phase Visible Disconnects Liquid Level Gauge Optional External PT Control Power Fuse Wipes Trident Padmount 3-Phase OPEN/CLOSE Shotgun Adapter External Status Position Switches Padmount Linear Actuator Option for Custom Enclosures and Cable Ways Padmount Remote Pedestal Control Cabinet 10 The Power and Experience to Deliver Trayer Engineering Corporation 898 Pennsylvania Avenue • San Francisco • California • 94107 (415) 285-7770 • (800) 377-1774 • Fax (415) 285-0883 • sales@trayer.com • www.trayer.com