Section 08 (Support Info) - Specifications

advertisement
Expansion Control
PART 1 - GENERAL
1.01
RELATED DOCUMENTS
A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and
Division 01 Specification Sections, apply to this Section.
1.02
SUMMARY
A.
B.
1.03
DEFINITIONS
A.
B.
C.
D.
1.04
This Section includes the following:
1. Architectural joint systems for building interiors. (delete if not required)
2. Architectural joint systems for building exteriors. (delete if not required)
3. Architectural joint systems for open-air structures. (delete if not required)
Related Sections include the following:
1. Division 03 Section "Cast-in-Place Concrete" for cast-in architectural-joint-system frames furnished, but
not installed, in this Section.
2. Division 04 Section "Unit Masonry" for masonry wall joint systems.
3. Division 07 Section "Sheet Metal Roofing" for sheet metal roof joint systems.
4. Division 07 Section "Sheet Metal Flashing and Trim" for sheet metal wall joint systems.
5. Division 07 Section "Fire-Resistive Joint Systems" for liquid-applied joint sealants in fire-resistive
building joints.
6. Division 07 Section "Joint Sealants" for liquid-applied joint sealants.
Maximum Joint Width: Widest linear gap a joint system tolerates and in which it performs its designed
function without damaging its functional capabilities.
Minimum Joint Width: Narrowest linear gap a joint system tolerates and in which it performs its designed
function without damaging its functional capabilities.
Movement Capability: Value obtained from the difference between widest and narrowest widths of a joint.
Nominal Joint Width: The width of the linear opening specified in practice and in which the joint system is
installed.
SUBMITTALS
A.
B.
C.
D.
Shop Drawings: Provide the following for each joint system specified and obtain approval prior to fabrication
and shipment of materials to the job site:
1. Placement Drawings: Include line diagrams showing plans, elevations, sections, details, splices, blockout
requirement, entire route of each joint system, and attachments to other work. Where joint systems
change planes, provide isometric or clearly detailed drawing depicting how components interconnect.
Product Data: Submit copies of manufacturer’s latest published literature for materials specified herein for
approval, and obtain approval before materials are fabricated and delivered to the site. Data to clearly
indicate movement capability of cover assemblies and suitability of material used in exterior
seal for UV exposure.
Samples for Initial Selection: For each type of joint system indicated.
1. Include manufacturer's color charts showing the standard range of colors and finishes available for each
exposed metal and elastomeric seal material.
Certificates – Material test reports from qualified independent testing laboratory indicating and interpreting
test results relative to compliance of fire-rated expansion joint assemblies with requirements indicated.
To download detail, specs & photos visit www.c-sgroup.com
For technical and design assistance call 800-233-8493.
8.6
1.05
QUALITY ASSURANCE
A.
B.
C.
D.
E.
F.
1.06
Installer Qualifications: Approved by manufacturer.
Source Limitations: Obtain all architectural joint systems through one source from a single manufacturer.
Product Options: Drawings indicate size, profiles, and dimensional requirements of architectural joint
systems and are based on the specific systems indicated. Refer to Division 01 Section "Product
Requirements."
1. Do not modify intended aesthetic effects, as judged solely by Architect, except with Architect's approval.
If modifications are proposed, submit comprehensive explanatory data to Architect for review.
Loading Characteristics: Standard loading refers to covers that are capable of withstanding up to 500 lb. point
loads. Heavy-duty refers to covers that are capable of withstanding up to 2000 lb. point loads.
Fire-Test-Response Characteristics: Where indicated, provide architectural joint system and fire-barrier
assemblies identical to those of assemblies tested for fire resistance per UL 2079 and/or ASTM E 1966 by
a testing and inspecting agency acceptable to authorities having jurisdiction. Fire rating not less than the
rating of adjacent construction.
Manufacturer to provide 5 year warranty for all joint covers.
COORDINATION
A.
Coordinate installation of exterior wall joint systems with roof expansion assemblies to ensure that wall
transitions are watertight.
PART 2 - PRODUCTS
2.01
MATERIALS
A.
Aluminum: ASTM B 221, Alloy 6063-T6, 6063-T5, 6063-T52, 6061-T5, 6061-T6, 6061-T51, 6105-T5, 6105-T6,
6005-T5, 6005A-T5 or 6005A-T61 for extrusions; ASTM B 209, Alloy 6061-T6, 3003-H14, 5005-H34 for sheet
and plate.
1. Apply manufacturer's standard protective coating on aluminum surfaces to be placed in contact with
cementitious materials.
2. Mill Finish: AA-M10 (Mechanical Finish: as fabricated, unspecified).
3. Class II, Clear Anodic Finish: AA-M12C22A31 (Mechanical Finish: nonspecular as fabricated; Chemical
Finish: etched, medium matte; Anodic Coating: Architectural Class II, clear coating 0.010 mm or thicker)
complying with AAMA 611.
4. Class II, Color Anodic Finish: AA-M12C22A32/A34 (Mechanical Finish: nonspecular as fabricated;
Chemical Finish: etched, medium matte; Anodic Coating: Architectural Class II, integrally colored or
electrolytically deposited color coating 0.010 mm or thicker) complying with AAMA 611.
5. High-Performance Organic Finish (Two-Coat Fluoropolymer): AA-C12C40R1x (Chemical Finish: cleaned
with inhibited chemicals; Chemical Finish: conversion coating; Organic Coating: manufacturer's standard
two-coat, thermocured system consisting of specially formulated inhibitive primer and fluoropolymer
color top coat containing not less than 70 percent polyvinylidene fluoride resin by weight). Prepare, pre
treat, and apply coating to exposed metal surfaces to comply with AAMA 2604 and with coating and resin
manufacturers' written instructions.
B.
Stainless Steel: ASTM A 666, Type 304 for plates, sheet, and strips.
C.
D.
1. Finish: No.4, directional satin.
a. Grind and polish surfaces to produce uniform, directionally textured, polished finish indicated, free of
cross scratches. Run grain with long dimension of each piece.
b. When polishing is completed, passivate and rinse surfaces. Remove embedded foreign matter and
leave surfaces chemically clean.
Brass: ASTM B 36/B 36M, UNS Alloy C26000 for half hard sheet and coil.
Bronze: ASTM B 455, Alloy C38500 for extrusions; Alloy C28000 Muntz Metal for plates.
© Copyright 2011 Construction Specialties, Inc.
V 4-11
8.7
E.
F.
G.
H.
I.
2.02
ARCHITECTURAL JOINT SYSTEMS, GENERAL
A.
B.
2.03
Elastomeric Seals: Preformed elastomeric membranes or extrusions to be installed in metal frames.
Compression Seals: ASTM D2000; preformed rectangular elastomeric extrusions having internal baffle system
and designed to function under compression.
Fire Barriers: Any material or material combination, when fire tested after cycling, designated to resist the
passage of flame and hot gases through a movement joint and to meet performance criteria for required
rating period.
Moisture Barrier: 7-ply laminate reinforced Polyethylene.
Accessories: Manufacturer's standard anchors, clips, fasteners, set screws, spacers, and other accessories
compatible with material in contact, as indicated or required for complete installations.
General: Provide architectural joint systems of design, basic profile, materials, and operation indicated.
Provide units with capability to accommodate variations in adjacent surfaces.
Design architectural joint systems for the following size and movement characteristics:
1. Nominal Joint Width: [As indicated on Drawings] [As scheduled] <Insert width>.
2. Maximum Joint Width: [As indicated on Drawings] [As scheduled] <Insert width>.
3. Minimum Joint Width: [As indicated on Drawings] [As scheduled] <Insert width>.
4. Lateral Shear Movement Capability: [As indicated on Drawings] [As scheduled]
<Insert movement capability>.
ARCHITECTURAL JOINT SYSTEMS FOR BUILDING INTERIORS
A.
Construction Specialties, Inc., 6696 State Route 405 Highway, Muncy, PA, shall manufacture expansion joint cover
assemblies specified herein and indicated on the drawings. Other manufacturers may be accepted as substitutions
only if the manufacturer can demonstrate product compliance with the requirements of the contract documents.
Substitution requests must be reviewed prior to bid and must include the following information:
1.
2.
3.
4.
5.
B.
Details.
ASTM- E1399 test reports.
Mock-ups.
Reference list of projects with similar products as those specified herein.
Written 5 year warranty.
Floor-to-Floor Joint Systems: (delete if not required)
1. Basis-of-Design Product: Construction Specialties, Inc. model GFT, GFT-M
2. Type: Elastomeric seal.
a. Exposed Metal: Aluminum.
1) Finish: Mill.
b. Seal Material: CS Thermoplastic Rubber (TPR).
1) Color: As selected by Architect from manufacturer's standard range.
2) Gaskets to be dual durometer and have a flat profile and to be free of ridges/reveals that
collect dirt.
3. Attachment Method: Mechanical anchors.
4. Load Capacity: Standard duty.
5. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction. (delete if not required)
6. Moisture Barrier: Manufacturer's standard. (delete if not required)
C.
Floor-to-Floor Joint Systems: (delete if not required)
1. Basis-of-Design Product: Construction Specialties, Inc. model GFS, GFST, GFPS
To download detail, specs & photos visit www.c-sgroup.com
For technical and design assistance call 800-233-8493.
8.8
2. Type: Surface mounted.
3. Type: Elastomeric seal.
a. Exposed Metal: Aluminum.
1) Finish: Class II, clear anodic.
b. Seal Material: CS Thermoplastic Rubber (TPR).
1) Color: As selected by Architect from manufacturer's standard range.
2) Gaskets to be dual durometer and have a flat profile and to be free of ridges/reveals that
collect dirt.
4. Attachment Method: Mechanical anchors.
5. Load Capacity: Standard duty.
6. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction. (delete if not required)
7. Moisture Barrier: Manufacturer's standard. (delete if not required)
D.
Floor-to-Floor Joint Systems: (delete if not required)
1. Basis-of-Design Product: Construction Specialties, Inc. model GTR, GTR-M DGTR, DGTR-M
2. Type: Dual elastomeric seal.
a. Exposed Metal: Aluminum.
1) Finish: Mill.
b. Seal Material: CS Thermoplastic Rubber (TPR).
1) Color: As selected by Architect from manufacturer's standard range.
2) Gaskets to be dual durometer and have a flat profile and to be free of ridges/reveals that
collect dirt.
3. Cover-Plate Design: Recessed to accept field-applied finish materials.
a. Recess Depth: 1/8 inch.
b. Cover plate held in place with turnbar. Spring clips do not consistently comply with ASTM-E1399
testing and are not acceptable.
4. Attachment Method: Mechanical anchors.
5. Load Capacity: Standard duty.
6. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction. (delete if not required)
7. Moisture Barrier: Manufacturer's standard. (delete if not required)
E.
Floor-to-Floor Joint Systems: (delete if not required)
1. Basis-of-Design Product: Construction Specialties, Inc. model GTR-D, GTR-DM DGTR-D, DGTR-DM
2. Type: Dual elastomeric seal.
a. Exposed Metal: Aluminum.
1) Finish: Mill.
b. Seal Material: CS Thermoplastic Rubber (TPR).
1) Color: As selected by Architect from manufacturer's standard range.
2) Gaskets to be dual durometer and have a flat profile and to be free of ridges/reveals that
collect dirt.
3. Cover-Plate Design: Recessed to accept field-applied flexible finish materials.
a. Recess Depth: 3/8 inch.
b. Cover plate held in place with turnbar. Spring clips do not consistently comply with ASTM-E1399
testing and are not acceptable.
4. Attachment Method: Mechanical anchors.
5. Load Capacity: Standard duty.
6. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction. (delete if not required)
7. Moisture Barrier: Manufacturer's standard. (delete if not required)
F.
Floor-to-Floor Joint Systems: (delete if not required)
© Copyright 2011 Construction Specialties, Inc.
V 4-11
8.9
1. Basis-of-Design Product: Construction Specialties, Inc. model GTP, GTP-M, DGTP, DGTP-M
2. Type: Dual elastomeric seal.
a. Exposed Metal: Aluminum.
1) Finish: Mill.
b. Seal Material: CS Thermoplastic Rubber (TPR).
1) Color: As selected by Architect from manufacturer's standard range.
2) Gaskets to be dual durometer and have a flat profile and to be free of ridges/reveals that
collect dirt.
3. Cover-Plate Design: Plain.
a. Cover plate held in place with turnbar. Spring clips do not consistently comply with ASTM-E1399
testing and are not acceptable.
4. Attachment Method: Mechanical anchors.
5. Load Capacity: Standard duty.
6. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction. (delete if not required)
7. Moisture Barrier: Manufacturer's standard. (delete if not required)
G.
Floor-to-Floor Joint Systems: (delete if not required)
1. Basis-of-Design Product: Construction Specialties, Inc. model GTP-HD, DGTP-HD
2. Type: Dual elastomeric seal.
a. Exposed Metal: Aluminum.
1) Finish: Mill.
b. Seal Material: CS Thermoplastic Rubber (TPR).
1) Color: As selected by Architect from manufacturer's standard range.
2) Gaskets to be dual durometer and have a flat profile and to be free of ridges/reveals that
collect dirt.
3. Cover-Plate Design: Plain.
a. Cover plate held in place with turnbar. Spring clips do not consistently comply with ASTM-E1399
testing and are not acceptable.
4. Attachment Method: Mechanical anchors.
5. Load Capacity: Heavy duty.
6. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction. (delete if not required)
7. Moisture Barrier: Manufacturer's standard. (delete if not required)
H.
Floor-to-Floor Joint Systems: (delete if not required)
1. Basis-of-Design Product: Construction Specialties, Inc. model SGP
2. Type: Dual elastomeric seal.
a. Exposed Metal: Aluminum.
1) Finish: Mill.
b. Seal Material: CS Thermoplastic Rubber (TPR).
1) Color: As selected by Architect from manufacturer's standard range.
2) Gaskets to be dual durometer and have a flat profile and to be free of ridges/reveals that
collect dirt.
3. Cover-Plate Design: Plain.
4. Attachment Method: Mechanical anchors.
5. Load Capacity: Standard duty.
6. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction. (delete if not required)
7. Moisture Barrier: Manufacturer's standard. (delete if not required)
I.
Floor-to-Floor Joint Systems: (delete if not required)
To download detail, specs & photos visit www.c-sgroup.com
For technical and design assistance call 800-233-8493.
8.10
1. Basis-of-Design Product: Construction Specialties, Inc. model SGR
2. Type: Dual elastomeric seal.
a. Exposed Metal: Aluminum.
1) Finish: Mill.
b. Seal Material: CS Thermoplastic Rubber (TPR).
1) Color: As selected by Architect from manufacturer's standard range.
2) Gaskets to be dual durometer and have a flat profile and to be free of ridges/reveals that
collect dirt.
3. Cover-Plate Design: Recessed to accept field-applied finish materials.
a. Recess Depth: 1/8 inch.
4. Attachment Method: Mechanical anchors.
5. Load Capacity: Standard duty.
6. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction. (delete if not required)
7. Moisture Barrier: Manufacturer's standard. (delete if not required)
J.
Floor-to-Floor Joint Systems: (delete if not required)
1. Basis-of-Design Product: Construction Specialties, Inc. model ALR, ALR-M
2. Type: Cover plate.
a. Exposed Metal: Aluminum.
1) Finish: Mill.
3. Cover Side Frame Design: Recessed to accept field-applied finish materials.
a. Recess Depth: 1/8 inch.
4. Cover Plate Design: Plain
5. Attachment Method: Mechanical anchors.
6. Load Capacity: Standard duty.
7. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction. (delete if not required)
8. Moisture Barrier: Manufacturer's standard. (delete if not required)
K.
Floor-to-Floor Joint Systems: (delete if not required)
1.
2.
3.
4.
5.
6.
7.
8.
L.
Basis-of-Design Product: Construction Specialties, Inc. model ALS, ALS-M
Type: Cover plate.
a. Exposed Metal: Aluminum.
1) Finish: Mill.
Cover Side Frame Design: Serrated.
Cover Plate Design: Plain
Attachment Method: Mechanical anchors.
Load Capacity: Standard duty.
Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction. (delete if not required)
Moisture Barrier: Manufacturer's standard. (delete if not required)
Floor-to-Floor Joint Systems: (delete if not required)
1.
2.
3.
4.
5.
6.
Basis-of-Design Product: Construction Specialties, Inc. model AL-HD, AL-HDM
Type: Cover plate.
a. Exposed Metal: Aluminum.
1) Finish: Mill.
Cover Side Frame Design: Serrated.
Cover Plate Design: Plain
Attachment Method: Mechanical anchors.
Load Capacity: Heavy duty.
© Copyright 2011 Construction Specialties, Inc.
V 4-11
8.11
7.
8.
M.
Floor-to-Floor Joint Systems: (delete if not required)
1.
2.
3.
4.
5.
6.
7.
8.
N.
3.
4.
5.
6.
7.
8.
Basis-of-Design Product: Construction Specialties, Inc. model FYW-D
Type: Cover plate.
a. Exposed Metal: Aluminum.
1) Finish: Mill.
Cover Side Frame Design: Recessed to accept field-applied finish materials.
a. Recess Depth: 1/4 inch.
Cover Plate Design: Plain
Attachment Method: Mechanical anchors.
Load Capacity: Standard duty.
Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction. (delete if not required)
Moisture Barrier: Manufacturer's standard. (delete if not required)
Floor-to-Floor Joint Systems: (delete if not required)
1.
2.
3.
4.
5.
6.
7.
P.
Basis-of-Design Product: Construction Specialties, Inc. model FYW
Type: Cover plate.
a. Exposed Metal: Aluminum.
1) Finish: Mill.
Cover Side Frame Design: Recessed to accept field-applied finish materials.
a. Recess Depth: 1/8 inch.
Cover Plate Design: Plain
Attachment Method: Mechanical anchors.
Load Capacity: Standard duty.
Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction. (delete if not required)
Moisture Barrier: Manufacturer's standard. (delete if not required)
Floor-to-Floor Joint Systems: (delete if not required)
1.
2.
O.
Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction. (delete if not required)
Moisture Barrier: Manufacturer's standard. (delete if not required)
Basis-of-Design Product: Construction Specialties, Inc. model PC
Type: Glide plate.
a. Exposed Metal: Aluminum.
1) Finish: Class II, clear anodic.
Cover-Plate Design: Plain.
Attachment Method: Mechanical anchors.
Load Capacity: Standard duty.
Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction. (delete if not required)
Moisture Barrier: Manufacturer's standard. (delete if not required)
Floor-to-Floor Joint Systems: (delete if not required)
1.
2.
3.
Basis-of-Design Product: Construction Specialties, Inc. model SJP, SJP-M, SJPF, SJPF-M
Type: Cover plate.
a. Exposed Metal: Aluminum.
1) Finish: Mill.
Cover Plate Design: Plain
To download detail, specs & photos visit www.c-sgroup.com
For technical and design assistance call 800-233-8493.
8.12
4.
5.
6.
7.
Q.
Floor-to-Floor Joint Systems: (delete if not required)
1.
2.
3.
4.
5.
6.
7.
R.
3.
4.
5.
6.
7.
Basis-of-Design Product: Construction Specialties, Inc. model APF
Type: Cover plate.
a. Exposed Metal: Aluminum.
1) Finish: Mill.
Cover Plate Design: Serrated/Striated
Attachment Method: Mechanical anchors.
Load Capacity: Heavy duty.
Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction. (delete if not required)
Moisture Barrier: Manufacturer's standard. (delete if not required)
Floor-to-Floor Joint Systems: (delete if not required)
1.
2.
3.
4.
5.
6.
7.
T.
Basis-of-Design Product: Construction Specialties, Inc. model SJ-HD, SJ-HDM
Type: Cover plate.
a. Exposed Metal: Aluminum.
1) Finish: Mill.
Cover Plate Design: Plain
Attachment Method: Mechanical anchors.
Load Capacity: Heavy duty.
Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction. (delete if not required)
Moisture Barrier: Manufacturer's standard. (delete if not required)
Floor-to-Floor Joint Systems: (delete if not required)
1.
2.
S.
Attachment Method: Mechanical anchors.
Load Capacity: Standard duty.
Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction. (delete if not required)
Moisture Barrier: Manufacturer's standard. (delete if not required)
Basis-of-Design Product: Construction Specialties, Inc. model SSR
Type: Pan.
a. Exposed Metal: Aluminum.
1) Finish: Mill.
2) Center pan that receives finish material must be extruded. Pans formed from sheet or plate products
are not acceptable.
Cover-Plate Design: Recessed to accept field-applied finish materials.
a. Recess Depth: 1” minimum.
Attachment Method: Mechanical anchors.
Load Capacity: Standard duty.
Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction. (delete if not required)
Moisture Barrier: Manufacturer's standard. (delete if not required)
Floor-to-Floor Joint Systems: (delete if not required)
1.
2.
Basis-of-Design Product: Construction Specialties, Inc. model SSRH
Type: Pan.
a. Exposed Metal: Aluminum.
1) Finish: Mill.
2) Center pan that receives finish material must be extruded. Pans formed from sheet or plate products
are not acceptable.
© Copyright 2011 Construction Specialties, Inc.
V 4-11
8.13
3.
4.
5.
6.
7.
U.
Floor-to-Wall Joint Systems: (delete if not required)
1.
2.
3.
4.
5.
6.
V.
Basis-of-Design Product: Construction Specialties, Inc. model GFTW
Type: Elastomeric seal.
a. Exposed Metal: Aluminum.
1) Finish: Mill.
b. Seal Material: CS Thermoplastic Rubber (TPR).
1) Color: As selected by Architect from manufacturer's standard range.
2) Gaskets to be dual durometer and have a flat profile and to be free of ridges/reveals that collect dirt.
Attachment Method: Mechanical anchors.
Load Capacity: Standard duty.
Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction. (delete if not required)
Moisture Barrier: Manufacturer's standard. (delete if not required)
Floor-to-Wall Joint Systems: (delete if not required)
1.
2.
3.
4.
5.
6.
7.
W.
Cover-Plate Design: Recessed to accept field-applied finish materials.
a. Recess Depth: 1” minimum.
Attachment Method: Mechanical anchors.
Load Capacity: Standard duty.
Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction. (delete if not required)
Moisture Barrier: Manufacturer's standard. (delete if not required)
Basis-of-Design Product: Construction Specialties, Inc. model GFSW, GFSTW, GFPSW
Type: Surface mounted.
Type: Elastomeric seal.
a. Exposed Metal: Aluminum.
1) Finish: Class II, clear anodic.
b. Seal Material: CS Thermoplastic Rubber (TPR).
1) Color: As selected by Architect from manufacturer's standard range.
2) Gaskets to be dual durometer and have a flat profile and to be free of ridges/reveals that collect dirt.
Attachment Method: Mechanical anchors.
Load Capacity: Standard duty.
Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction. (delete if not required)
Moisture Barrier: Manufacturer's standard. (delete if not required)
Floor-to-Wall Joint Systems: (delete if not required)
1.
2.
3.
4.
5.
6.
7.
Basis-of-Design Product: Construction Specialties, Inc. model GTRW, DGTRW
Type: Dual elastomeric seal.
a. Exposed Metal: Aluminum.
1) Finish: Mill.
b. Seal Material: CS Thermoplastic Rubber (TPR).
1) Color: As selected by Architect from manufacturer's standard range.
2) Gaskets to be dual durometer and have a flat profile and to be free of ridges/reveals that collect dirt.
Cover-Plate Design: Recessed to accept field-applied finish materials.
a. Recess Depth: 1/8 inch.
Attachment Method: Mechanical anchors.
Load Capacity: Standard duty.
Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction. (delete if not required)
Moisture Barrier: Manufacturer's standard. (delete if not required)
To download detail, specs & photos visit www.c-sgroup.com
For technical and design assistance call 800-233-8493.
8.14
X.
Floor-to-Wall Joint Systems: (delete if not required)
1.
2.
3.
4.
5.
6.
7.
Y.
Floor-to-Wall Joint Systems: (delete if not required)
1.
2.
3.
4.
5.
6.
7.
Z.
Basis-of-Design Product: Construction Specialties, Inc. model GTPW, DGTPW
Type: Dual elastomeric seal.
a. Exposed Metal: Aluminum.
1) Finish: Mill.
b. Seal Material: CS Thermoplastic Rubber (TPR).
1) Color: As selected by Architect from manufacturer's standard range.
2) Gaskets to be dual durometer and have a flat profile and to be free of ridges/reveals that collect dirt.
Cover-Plate Design: Plain.
Attachment Method: Mechanical anchors.
Load Capacity: Standard duty.
Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction. (delete if not required)
Moisture Barrier: Manufacturer's standard. (delete if not required)
Floor-to-Wall Joint Systems: (delete if not required)
1.
2.
3.
4.
5.
6.
7.
AA.
Basis-of-Design Product: Construction Specialties, Inc. model GTRW-D, DGTRW-D
Type: Dual elastomeric seal.
a. Exposed Metal: Aluminum.
1) Finish: Mill.
b. Seal Material: CS Thermoplastic Rubber (TPR).
1) Color: As selected by Architect from manufacturer's standard range.
2) Gaskets to be dual durometer and have a flat profile and to be free of ridges/reveals that collect dirt.
Cover-Plate Design: Recessed to accept field-applied flexible finish materials.
a. Recess Depth: 3/8 inch.
Attachment Method: Mechanical anchors.
Load Capacity: Standard duty.
Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction. (delete if not required)
Moisture Barrier: Manufacturer's standard. (delete if not required)
Basis-of-Design Product: Construction Specialties, Inc. model GTPW-HD, DGTPW-HD
Type: Dual elastomeric seal.
a. Exposed Metal: Aluminum.
1) Finish: Mill.
b. Seal Material: CS Thermoplastic Rubber (TPR).
1) Color: As selected by Architect from manufacturer's standard range.
2) Gaskets to be dual durometer and have a flat profile and to be free of ridges/reveals that collect dirt.
Cover-Plate Design: Plain.
Attachment Method: Mechanical anchors.
Load Capacity: Heavy duty.
Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction. (delete if not required)
Moisture Barrier: Manufacturer's standard. (delete if not required)
Floor-to-Wall Joint Systems: (delete if not required)
1.
2.
Basis-of-Design Product: Construction Specialties, Inc. model SGPW
Type: Dual elastomeric seal.
a. Exposed Metal: Aluminum.
1) Finish: Mill.
© Copyright 2011 Construction Specialties, Inc.
V 4-11
8.15
3.
4.
5.
6.
7.
BB.
Floor-to-Wall Joint Systems: (delete if not required)
1.
2.
3.
4.
5.
6.
7.
CC.
Basis-of-Design Product: Construction Specialties, Inc. model SGRW
Type: Dual elastomeric seal.
a. Exposed Metal: Aluminum.
1) Finish: Mill.
b. Seal Material: CS Thermoplastic Rubber (TPR).
1) Color: As selected by Architect from manufacturer's standard range.
2) Gaskets to be dual durometer and have a flat profile and to be free of ridges/reveals that
collect dirt.
Cover-Plate Design: Recessed to accept field-applied finish materials.
a. Recess Depth: 1/8 inch.
Attachment Method: Mechanical anchors.
Load Capacity: Standard duty.
Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction. (delete if not required)
Moisture Barrier: Manufacturer's standard. (delete if not required)
Floor-to-Wall Joint Systems: (delete if not required)
1.
2.
3.
4.
5.
6.
7.
8.
DD.
b. Seal Material: CS Thermoplastic Rubber (TPR).
1) Color: As selected by Architect from manufacturer's standard range.
2) Gaskets to be dual durometer and have a flat profile and to be free of ridges/reveals that collect dirt.
Cover-Plate Design: Plain.
Attachment Method: Mechanical anchors.
Load Capacity: Standard duty.
Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction. (delete if not required)
Moisture Barrier: Manufacturer's standard. (delete if not required)
Basis-of-Design Product: Construction Specialties, Inc. model ALRW
Type: Cover plate.
a. Exposed Metal: Aluminum.
1) Finish: Mill.
Cover Side Frame Design: Recessed to accept field-applied finish materials.
a. Recess Depth: 1/8 inch.
Cover Plate Design: Plain
Attachment Method: Mechanical anchors.
Load Capacity: Standard duty.
Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction. (delete if not required)
Moisture Barrier: Manufacturer's standard. (delete if not required)
Floor-to-Wall Joint Systems: (delete if not required)
1.
2.
3.
4.
5.
6.
7.
Basis-of-Design Product: Construction Specialties, Inc. model ALSW
Type: Cover plate.
a. Exposed Metal: Aluminum.
1) Finish: Mill.
Cover Side Frame Design: Serrated.
Cover Plate Design: Plain
Attachment Method: Mechanical anchors.
Load Capacity: Standard duty.
Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction. (delete if not required)
To download detail, specs & photos visit www.c-sgroup.com
For technical and design assistance call 800-233-8493.
8.16
8.
EE.
Floor-to-Wall Joint Systems: (delete if not required)
1.
2.
3.
4.
5.
6.
7.
8.
FF.
3.
4.
5.
6.
7.
8.
Basis-of-Design Product: Construction Specialties, Inc. model FYWW
Type: Cover plate.
a. Exposed Metal: Aluminum.
1) Finish: Mill.
Cover Side Frame Design: Recessed to accept field-applied finish materials.
a. Recess Depth: 1/8 inch.
Cover Plate Design: Plain
Attachment Method: Mechanical anchors.
Load Capacity: Standard duty.
Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction. (delete if not required)
Moisture Barrier: Manufacturer's standard. (delete if not required)
Floor-to-Wall Joint Systems: (delete if not required)
1.
2.
3.
4.
5.
6.
7.
8.
HH.
Basis-of-Design Product: Construction Specialties, Inc. model ALW-HD
Type: Cover plate.
a. Exposed Metal: Aluminum.
1) Finish: Mill.
Cover Side Frame Design: Serrated.
Cover Plate Design: Plain
Attachment Method: Mechanical anchors.
Load Capacity: Heavy duty.
Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction. (delete if not required)
Moisture Barrier: Manufacturer's standard. (delete if not required)
Floor-to-Wall Joint Systems: (delete if not required)
1.
2.
GG.
Moisture Barrier: Manufacturer's standard. (delete if not required)
Basis-of-Design Product: Construction Specialties, Inc. model FYWW-D
Type: Cover plate.
a. Exposed Metal: Aluminum.
1) Finish: Mill.
Cover Side Frame Design: Recessed to accept field-applied finish materials.
a. Recess Depth: 1/4 inch.
Cover Plate Design: Plain
Attachment Method: Mechanical anchors.
Load Capacity: Standard duty.
Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction. (delete if not required)
Moisture Barrier: Manufacturer's standard. (delete if not required)
Floor-to-Wall Joint Systems: (delete if not required)
1.
2.
Basis-of-Design Product: Construction Specialties, Inc. model PCW
Type: Glide plate.
a. Exposed Metal: Aluminum.
1) Finish: Class II, clear anodic.
© Copyright 2011 Construction Specialties, Inc.
V 4-11
8.17
3.
4.
5.
6.
7.
II.
Floor-to-Wall Joint Systems: (delete if not required)
1.
2.
3.
4.
5.
6.
7.
JJ.
3.
4.
5.
6.
7.
Basis-of-Design Product: Construction Specialties, Inc. model SJW-HD
Type: Cover plate.
a. Exposed Metal: Aluminum.
1) Finish: Mill.
Cover Plate Design: Plain
Attachment Method: Mechanical anchors.
Load Capacity: Heavy duty.
Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction. (delete if not required)
Moisture Barrier: Manufacturer's standard. (delete if not required)
Floor-to-Wall Joint Systems: (delete if not required)
1.
2.
3.
4.
5.
6.
7.
LL.
Basis-of-Design Product: Construction Specialties, Inc. model SJPW, SJPFW
Type: Cover plate.
a. Exposed Metal: Aluminum.
1) Finish: Mill.
Cover Plate Design: Plain
Attachment Method: Mechanical anchors.
Load Capacity: Standard duty.
Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction. (delete if not required)
Moisture Barrier: Manufacturer's standard. (delete if not required)
Floor-to-Wall Joint Systems: (delete if not required)
1.
2.
KK.
Cover-Plate Design: Plain.
Attachment Method: Mechanical anchors.
Load Capacity: Standard duty.
Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction. (delete if not required)
Moisture Barrier: Manufacturer's standard. (delete if not required)
Basis-of-Design Product: Construction Specialties, Inc. model APFW
Type: Cover plate.
a. Exposed Metal: Aluminum.
1) Finish: Mill.
Cover Plate Design: Serrated/Striated
Attachment Method: Mechanical anchors.
Load Capacity: Heavy duty.
Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction. (delete if not required)
Moisture Barrier: Manufacturer's standard. (delete if not required)
Floor-to-Wall Joint Systems: (delete if not required)
1.
2.
Basis-of-Design Product: Construction Specialties, Inc. model SSRW
Type: Pan.
a. Exposed Metal: Aluminum.
1) Finish: Mill.
2) Center pan that receives finish material must be extruded. Pans formed from sheet or plate products
are not acceptable.
To download detail, specs & photos visit www.c-sgroup.com
For technical and design assistance call 800-233-8493.
8.18
3.
4.
5.
6.
7.
MM.
Wall-to-Wall Joint Systems: (delete if not required)
1.
2.
3.
NN.
3.
Basis-of-Design Product: Construction Specialties, Inc. model FWS, FWS-M
Type: Accordion – substitution of flat seal profiles is not acceptable.
a. Exposed Metal: Aluminum.
1) Finish: Mill.
b. Seal Material: Santoprene.
1) Color: As selected by Architect from manufacturer's standard range.
Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction. (delete if not required)
Wall-to-Wall Joint Systems: (delete if not required)
1.
2.
3.
4.
5.
6.
PP.
Basis-of-Design Product: Construction Specialties, Inc. model FWF, FWF-M
Type: Flat seal.
a. Exposed Metal: Aluminum.
1) Finish: Mill.
b. Seal Material: Santoprene.
1) Color: As selected by Architect from manufacturer's standard range.
Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction. (delete if not required)
Wall-to-Wall Joint Systems: (delete if not required)
1.
2.
OO.
Cover-Plate Design: Recessed to accept field-applied finish materials.
a. Recess Depth: 1” minimum.
Attachment Method: Mechanical anchors.
Load Capacity: Heavy duty.
Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction. (delete if not required)
Moisture Barrier: Manufacturer's standard. (delete if not required)
Basis-of-Design Product: Construction Specialties, Inc. model GFS-W
Type: Surface mounted.
Type: Elastomeric seal.
a. Exposed Metal: Aluminum.
1) Finish: Class II, clear anodic.
b. Seal Material: CS Thermoplastic Rubber (TPR).
1) Color: As selected by Architect from manufacturer's standard range.
Attachment Method: Mechanical anchors.
Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction. (delete if not required)
Moisture Barrier: Manufacturer's standard. (delete if not required)
Wall-to-Wall Joint Systems: (delete if not required)
1.
2.
3.
4.
5.
Basis-of-Design Product: Construction Specialties, Inc. model GTW
Type: Dual elastomeric seal.
a. Exposed Metal: Aluminum.
1) Finish: Class II, clear anodic.
b. Seal Material: CS Thermoplastic Rubber (TPR).
1) Color: As selected by Architect from manufacturer's standard range.
Cover-Plate Design: Plain.
Attachment Method: Mechanical anchors.
Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
© Copyright 2011 Construction Specialties, Inc.
V 4-11
8.19
6.
QQ.
Wall-to-Wall Joint Systems: (delete if not required)
1.
2.
3.
4.
5.
6.
RR.
3.
4.
5.
6.
3.
4.
Basis-of-Design Product: Construction Specialties, Inc. model AFW, ASM
Type: Snap-on cover.
a. Exposed Metal: Aluminum.
1) Finish: Class II, clear anodic.
Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction. (delete if not required)
Moisture Barrier: Manufacturer's standard. (delete if not required)
Wall-to-Wall Joint Systems: (delete if not required)
1.
2.
3.
4.
UU.
Basis-of-Design Product: Construction Specialties, Inc. model LAF, LAS
Type: Vertical cover panel
a. Exposed Metal: Aluminum.
1) Panel Finish: Factory applied clear epoxy primer and field applied paint or wall covering.
2) Frame Finish: Class II, clear anodic.
Panels held in place with hook and loop attachment system and incorporate a secondary system comprised
of a pre-tensioned shock cord.
Covers that utilize turnbars or other similar centering devices limit lateral shear movement and are not
acceptable.
Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction. (delete if not required)
Moisture Barrier: Manufacturer's standard. (delete if not required)
Wall-to-Wall Joint Systems: (delete if not required)
1.
2.
TT.
Basis-of-Design Product: Construction Specialties, Inc. model SGW
Type: Dual elastomeric seal.
a. Exposed Metal: Aluminum.
1) Finish: Class II, clear anodic.
b. Seal Material: CS Thermoplastic Rubber (TPR).
1) Color: As selected by Architect from manufacturer's standard range.
Cover-Plate Design: Plain.
Attachment Method: Mechanical anchors.
Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction. (delete if not required)
Moisture Barrier: Manufacturer's standard. (delete if not required)
Wall-to-Wall Joint Systems: (delete if not required)
1.
2.
SS.
adjacent construction. (delete if not required)
Moisture Barrier: Manufacturer's standard. (delete if not required)
Basis-of-Design Product: Construction Specialties, Inc. model SFW
Type: Vertical cover plate.
a. Exposed Metal: Aluminum.
1) Finish: Class II, clear anodic.
Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction. (delete if not required)
Moisture Barrier: Manufacturer's standard. (delete if not required)
Wall Corner Joint Systems: (delete if not required)
To download detail, specs & photos visit www.c-sgroup.com
For technical and design assistance call 800-233-8493.
8.20
1.
2.
3.
VV.
Wall Corner Joint Systems: (delete if not required)
1.
2.
3.
WW.
3.
4.
5.
6.
Basis-of-Design Product: Construction Specialties, Inc. model GTWC
Type: Dual elastomeric seal.
a. Exposed Metal: Aluminum.
1) Finish: Class II, clear anodic.
b. Seal Material: CS Thermoplastic Rubber (TPR).
1) Color: As selected by Architect from manufacturer's standard range.
Cover-Plate Design: Plain.
Attachment Method: Mechanical anchors.
Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction. (delete if not required)
Moisture Barrier: Manufacturer's standard. (delete if not required)
Wall Corner Joint Systems: (delete if not required)
1.
2.
3.
4.
5.
6.
YY.
Basis-of-Design Product: Construction Specialties, Inc. model FWSC, FWSC-M
Type: Accordion – substitution of flat seal profiles is not acceptable.
a. Exposed Metal: Aluminum.
1) Finish: Mill.
b. Seal Material: Santoprene.
1) Color: As selected by Architect from manufacturer's standard range.
Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction. (delete if not required)
Wall Corner Joint Systems: (delete if not required)
1.
2.
XX.
Basis-of-Design Product: Construction Specialties, Inc. model FWFC, FWFC-M
Type: Flat seal.
a. Exposed Metal: Aluminum.
1) Finish: Mill.
b. Seal Material: Santoprene.
1) Color: As selected by Architect from manufacturer's standard range.
Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction. (delete if not required)
Basis-of-Design Product: Construction Specialties, Inc. model SGWC
Type: Dual elastomeric seal.
a. Exposed Metal: Aluminum.
1) Finish: Class II, clear anodic.
b. Seal Material: CS Thermoplastic Rubber (TPR).
1) Color: As selected by Architect from manufacturer's standard range.
Cover-Plate Design: Plain.
Attachment Method: Mechanical anchors.
Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction. (delete if not required)
Moisture Barrier: Manufacturer's standard. (delete if not required)
Wall Corner Joint Systems: (delete if not required)
1.
2.
Basis-of-Design Product: Construction Specialties, Inc. model LAFC, LASC
Type: Vertical cover panel
a. Exposed Metal: Aluminum.
1) Panel Finish: Factory applied clear epoxy primer and field applied paint or wall covering.
© Copyright 2011 Construction Specialties, Inc.
V 4-11
8.21
3.
4.
5.
6.
ZZ.
2) Frame Finish: Class II, clear anodic.
Panels held in place with hook and loop attachment system and incorporate a secondary system comprised
of a pre-tensioned shock cord.
Covers that utilize turnbars or other similar centering devices limit lateral shear movement and are not
acceptable.
Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction. (delete if not required)
Moisture Barrier: Manufacturer's standard. (delete if not required)
Wall Corner Joint Systems: (delete if not required)
1.
2.
3.
4.
Basis-of-Design Product: Construction Specialties, Inc. model AFWC, ASMC
Type: Snap-on cover.
a. Exposed Metal: Aluminum.
1) Finish: Class II, clear anodic.
Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction. (delete if not required)
Moisture Barrier: Manufacturer's standard. (delete if not required)
AAA. Wall Corner Joint Systems: (delete if not required)
1.
2.
3.
4.
BBB.
Wall-to-Ceiling Joint Systems: (delete if not required)
1.
2.
CCC.
Basis-of-Design Product: Construction Specialties, Inc. model SCW
Type: Vertical cover plate.
a. Exposed Metal: Aluminum.
1) Finish: Class II, clear anodic.
Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction. (delete if not required)
Moisture Barrier: Manufacturer's standard. (delete if not required)
Basis-of-Design Product: Construction Specialties, Inc. model HCW
Type: Accordion.
a. Seal Material: PVC.
1) Color: White.
Wall-to-Ceiling Joint Systems: (delete if not required)
1.
2.
Basis-of-Design Product: Construction Specialties, Inc. model FCFC
Type: Flat seal.
a. Exposed Metal: Aluminum.
1) Finish: Mill.
b. Seal Material: Santoprene.
1) Color: As selected by Architect from manufacturer's standard range.
DDD. Wall-to-Ceiling Joint Systems: (delete if not required)
1.
2.
Basis-of-Design Product: Construction Specialties, Inc. model FCSC
Type: Accordion - substitution of flat seal profiles is not acceptable.
a. Exposed Metal: Aluminum.
1) Finish: Mill.
b. Seal Material: Santoprene.
1) Color: As selected by Architect from manufacturer's standard range.
To download detail, specs & photos visit www.c-sgroup.com
For technical and design assistance call 800-233-8493.
8.22
EEE.
Wall-to-Ceiling Joint Systems: (delete if not required)
1.
2.
3.
4.
FFF.
Basis-of-Design Product: Construction Specialties, Inc. model SGCC
Type: Dual reveal.
a. Exposed Metal: Aluminum.
1) Finish: Class II, clear anodic.
Cover-Plate Design: Plain.
Attachment Method: Mechanical anchors.
Wall-to-Ceiling Joint Systems: (delete if not required)
1.
2.
Basis-of-Design Product: Construction Specialties, Inc. model SCC
Type: Vertical cover plate.
a. Exposed Metal: Aluminum.
1) Finish: Class II, clear anodic.
GGG. Wall-to-Ceiling Joint Systems: (delete if not required)
1.
2.
3.
4.
Basis-of-Design Product: Construction Specialties, Inc. model LAFC, LASC
Type: Cover panel
a. Exposed Metal: Aluminum.
1) Panel Finish: Factory applied clear epoxy primer and field applied paint or wall covering.
2) Frame Finish: Class II, clear anodic.
Panels held in place with hook and loop attachment system and incorporate a secondary system comprised
of a pre-tensioned shock cord.
Covers that utilize turnbars or other similar centering devices limit lateral shear movement and are not
acceptable.
HHH. Ceiling-to-Ceiling Joint Systems: (delete if not required)
1.
2.
III.
Ceiling-to-Ceiling Joint Systems: (delete if not required)
1.
2.
JJJ.
Basis-of-Design Product: Construction Specialties, Inc. model HC
Type: Accordion.
a. Seal Material: PVC.
1) Color: White.
Basis-of-Design Product: Construction Specialties, Inc. model FCF
Type: Flat seal.
a. Exposed Metal: Aluminum.
1) Finish: Mill.
b. Seal Material: Santoprene.
1) Color: As selected by Architect from manufacturer's standard range.
Ceiling-to-Ceiling Joint Systems: (delete if not required)
1.
2.
Basis-of-Design Product: Construction Specialties, Inc. model FCS
Type: Accordion - substitution of flat seal profiles is not acceptable.
a. Exposed Metal: Aluminum.
1) Finish: Mill.
b. Seal Material: Santoprene.
1) Color: As selected by Architect from manufacturer's standard range.
© Copyright 2011 Construction Specialties, Inc.
V 4-11
8.23
KKK.
Ceiling-to-Ceiling Joint Systems: (delete if not required)
1.
2.
3.
4.
LLL.
Basis-of-Design Product: Construction Specialties, Inc. model SGC
Type: Dual reveal.
a. Exposed Metal: Aluminum.
1) Finish: Class II, clear anodic.
Cover-Plate Design: Plain.
Attachment Method: Mechanical anchors.
Ceiling-to-Ceiling Joint Systems: (delete if not required)
1.
2.
3.
Basis-of-Design Product: Construction Specialties, Inc. model SFC
Type: Vertical cover plate.
a. Exposed Metal: Aluminum.
Finish: Class II, clear anodic.
MMM. Ceiling-to-Ceiling Joint Systems: (delete if not required)
1.
2.
3.
4.
Basis-of-Design Product: Construction Specialties, Inc. model LAF, LAS
Type: Cover panel
a. Exposed Metal: Aluminum.
1) Panel Finish: Factory applied clear epoxy primer and field applied paint or wall covering.
2) Frame Finish: Class II, clear anodic.
Panels held in place with hook and loop attachment system and incorporate a secondary system comprised
of a pre-tensioned shock cord.
Covers that utilize turnbars or other similar centering devices limit lateral shear movement and are not
acceptable.
2.04
ARCHITECTURAL JOINT SYSTEMS FOR BUILDING EXTERIORS
A.
Construction Specialties, Inc., P.O. Box 380 Muncy, PA, shall manufacture expansion joint cover assemblies
specified herein and indicated on the drawings. Other manufacturers may be accepted as substitutions only if the
manufacturer can demonstrate product compliance with the requirements of the contract documents. Substitution
requests must be reviewed prior to bid and must include the following information:
1.
2.
3.
4.
5.
B.
Details
ASTM- E1399 test reports
Mock-ups
Reference list of projects with similar products as those specified herein.
Written 5 year warranty
Architectural Joint Systems for Exterior Walls and Soffits: (delete if not required)
1.
2.
3.
4.
Basis-of-Design Product: Construction Specialties, Inc. model SF
Type: Flat seal.
a. Seal Material: Santoprene.
1) Color: As selected by Architect from manufacturer's standard range.
b. Secondary Seal: Manufacturer's standard extruded-elastomeric seal designed to prevent water and
moisture infiltration.
c. Pantograph Mechanism: Manufacturer's standard nylon pantographic wind-load support mechanism
with stainless-steel fasteners for 12” joints and larger.
All miters and changes in direction to be factory fabricated, heat welded transitions.
Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction. (delete if not required)
To download detail, specs & photos visit www.c-sgroup.com
For technical and design assistance call 800-233-8493.
8.24
C.
Architectural Joint Systems for Exterior Walls and Soffits: (delete if not required)
1. Basis-of-Design Product: Construction Specialties, Inc. model SC
2. Type: Accordion - substitution of flat seal profiles is not acceptable.
a. Seal Material: Santoprene.
1) Color: As selected by Architect from manufacturer's standard range.
b. Secondary Seal: Manufacturer's standard extruded-elastomeric seal designed to prevent water
and moisture infiltration.
c.
Pantograph Mechanism: Manufacturer's standard nylon pantographic wind-load support mechanism with
stainless-steel fasteners for 12” joints and larger.
3. All miters and changes in direction to be factory fabricated, heat welded transitions.
4. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction. (delete if not required)
D.
Architectural Joint Systems for Exterior Walls and Soffits: (delete if not required)
1.
2.
3.
E.
Basis-of-Design Product: Construction Specialties, Inc. model AFW-X
Type: Vertical cover-plate.
a. Exposed Metal: Aluminum.
1) Finish: Class II, clear anodic.
b. Secondary Seal: 7-ply laminate reinforced Polyethylene.
Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction. (delete if not required)
Architectural Joint Systems for Exterior Walls and Soffits: (delete if not required)
1.
2.
3.
Basis-of-Design Product: Construction Specialties, Inc. model ESW, ESC
Type: Vertical cover-plate.
a. Exposed Metal: Aluminum.
1) Finish: Class II, clear anodic.
b. Secondary Seal: 7-ply laminate reinforced Polyethylene.
Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction. (delete if not required)
F.
Architectural Joint Systems for Exterior Walls and Soffits: (delete if not required)
1. Basis-of-Design Product: Construction Specialties, Inc. model RJT-V, RJTW-V, SRJ-V, SRJW-V
2. Type: Vertical cover-plate.
a. Exposed Metal: Aluminum.
1) Finish: Mill.
b. Secondary Seal: 7-ply laminate reinforced Polyethylene.
3. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction. (delete if not required)
G.
Architectural Joint Systems for Exterior Walls: (delete if not required)
1. Basis-of-Design Product: Construction Specialties, Inc. model XLS, XLSC
2. Type: Pan.
a. Exposed Metal: Aluminum.
1) Finish: Mill.
3. Cover-Plate Design: Recessed to accept field-applied finish materials.
a. Recess Depth: 1” minimum.
4. Attachment Method: Mechanical anchors with continuous hinge to support panel and permit full range
of movements. Use of centering/tensioning bar assemblies will not be permitted. System to be secured in
nominal position with minimum (2) 400# pull magnets per 10’ assembly, and counterweighted to self-close
following a seismic event.
5. Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction. (delete if not required)
© Copyright 2011 Construction Specialties, Inc.
V 4-11
8.25
6.
H.
Moisture Barrier: 7-ply laminate reinforced Polyethylene.
Architectural Joint Systems for Exterior Roofs: (delete if not required)
1.
2.
3.
4.
I.
Basis-of-Design Product: Construction Specialties, Inc. model RJT, RJTW, SRJ, SRJW
Type: Vertical cover-plate.
a. Exposed Metal: Aluminum.
1) Finish: Mill.
b. Secondary Seal: 7-ply laminate reinforced Polyethylene.
Cover plate thickness shall be determined by the performance requirements of the roof, but shall be no less
than .090" thick.
Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction. (delete if not required)
Architectural Joint Systems for Exterior Roofs: (delete if not required)
1.
2.
3.
4.
Basis-of-Design Product: Construction Specialties, Inc. model BRJ, BRJW
Type: Bellows.
a. Metal Flange: Galvanized.
1) Finish: Mill.
b. Bellows: EPDM
c. Secondary Seal: Manufacturer's standard.
Factory Fabricated Transitions: all end caps, transitions and miters to be factory fabricated to ensure weather
integrity. Field fabrication is not acceptable.
Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction. (delete if not required)
2.05
ARCHITECTURAL JOINT SYSTEMS FOR OPEN-AIR STRUCTURES
A.
Construction Specialties, Inc., P.O. Box 380 Muncy, PA, shall manufacture expansion joint cover assemblies
specified herein and indicated on the drawings. Other manufacturers may be accepted as substitutions only if the
manufacturer can demonstrate product compliance with the requirements of the contract documents. Substitution
requests must be reviewed prior to bid and must include the following information:
1.
2.
3.
4.
5.
B.
Systems for Parking Structures: (delete if not required)
1.
2.
3.
4.
5.
C.
Details
ASTM- E1399 test reports
Mock-ups
Reference list of projects with similar products as those specified herein.
Written 5 year warranty
Basis-of-Design Product: Construction Specialties, Inc. model ZB, ZBW
Type: Epoxy-bonded seal.
a. Seal Material: EPDM.
1) Color: Black.
Attachment Method: Compressed, epoxy adhered.
Load Capacity: Heavy duty.
Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction.
Joint Systems for Parking Structures: (delete if not required)
1.
Basis-of-Design Product: Construction Specialties, Inc. model HB
To download detail, specs & photos visit www.c-sgroup.com
For technical and design assistance call 800-233-8493.
8.26
2.
3.
4.
5.
D.
Joint Systems for Parking Structures: (delete if not required)
1.
2.
3.
4.
5.
E.
3.
4.
5.
6.
7.
8.
Basis-of-Design Product: Construction Specialties, Inc. model KB, KBW
Type: Metal plate.
a. Exposed Metal: Aluminum.
1) Finish: Manufacturer's standard finish.
2) Finish: Mill.
Center plate design to allow for vertical movement without cantilevering end of plate into the air.
Turnbar and center plate to have direct positive engagement to protect center bolt from shearing forces.
Attachment Method: Mechanical anchors
Load Capacity: Heavy duty.
Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction.
Gutter: 7-ply laminate reinforced Polyethylene.
Joint Systems for Parking Structures: (delete if not required)
1.
2.
3.
4.
5.
6.
7.
8.
G.
Basis-of-Design Product: Construction Specialties, Inc. model CSAB
Type: Winged seal.
a. Seal Material: Santoprene.
1) Color: Black.
Attachment Method: Mechanical anchors.
Load Capacity: Extra heavy duty to withstand AASHTO HS-20.
Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent.
Joint Systems for Parking Structures: (delete if not required)
1.
2.
F.
Type: Compression seal.
a. Seal Material: EPDM.
1) Color: Black.
Attachment Method: Compressed.
Load Capacity: Heavy duty.
Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent.
Basis-of-Design Product: Construction Specialties, Inc. model KB-HD, KBW-HD
Type: Metal plate.
a. Exposed Metal: Aluminum.
1) Finish: Manufacturer's standard finish.
2) Finish: Mill.
Center plate design to allow for vertical movement without cantilevering end of plate into the air.
Turnbar and center plate to have direct positive engagement to protect center bolt from shearing forces.
Attachment Method: Mechanical anchors
Load Capacity: Extra heavy duty to withstand AASHTO HS-20.
Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction.
Gutter: 7-ply laminate reinforced Polyethylene.
Joint Systems for Parking Structures: (delete if not required)
1.
Basis-of-Design Product: Construction Specialties, Inc. model KBC, KBCW
© Copyright 2011 Construction Specialties, Inc.
V 4-11
8.27
2.
3.
4.
5.
6.
7.
8.
H.
Joint Systems for Parking Structures: (delete if not required)
1.
2.
3.
4.
5.
6.
7.
8.
I.
Basis-of-Design Product: Construction Specialties, Inc. model KBC-HD, KBCW-HD
Type: Metal plate.
a. Exposed Metal: Aluminum.
1) Finish: Manufacturer's standard finish.
2) Finish: Mill.
Center plate design to allow for vertical movement without cantilevering end of plate into the air.
Turnbar and center plate to have direct positive engagement to protect center bolt from shearing forces.
Attachment Method: Cast in
Load Capacity: Extra heavy duty to withstand AASHTO HS-20.
Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction.
Gutter: 7-ply laminate reinforced Polyethylene.
Joint Systems for Parking Structures: (delete if not required)
1.
2.
3.
4.
5.
6.
J.
Type: Metal plate.
a. Exposed Metal: Aluminum.
1) Finish: Manufacturer's standard finish.
2) Finish: Mill.
Center plate design to allow for vertical movement without cantilevering end of plate into the air.
Turnbar and center plate to have direct positive engagement to protect center bolt from shearing forces.
Attachment Method: Cast in
Load Capacity: Heavy duty.
Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction.
Gutter: 7-ply laminate reinforced Polyethylene.
Basis-of-Design Product: Construction Specialties, Inc. model PTC, PTCW
Type: Metal plate.
a. Exposed Metal: Aluminum.
1) Finish: Manufacturer's standard finish.
2) Finish: Mill.
Attachment Method: Mechanical anchors
Load Capacity: Extra heavy duty to withstand AASHTO HS-20.
Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent construction.
Gutter: 7-ply laminate reinforced Polyethylene.
Joint Systems for Plaza Decks: (delete if not required)
1.
2.
3.
4.
5.
Basis-of-Design Product: Construction Specialties, Inc. model PDA
Type: Metal plate.
a. Exposed Metal: Aluminum.
1) Finish: Mill.
Type: Strip seal.
a. Primary seal Material: Santoprene.
1) Color: Black.
b. Wing seal Material: PVC
1) Color: Black
Attachment Method: Mechanical anchors.
Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent.
To download detail, specs & photos visit www.c-sgroup.com
For technical and design assistance call 800-233-8493.
8.28
K.
Joint Systems for Plaza Decks: (delete if not required)
1.
2.
3.
4.
5.
2.06
Basis-of-Design Product: Construction Specialties, Inc. model PDS
Type: Metal plate.
a. Exposed Metal: Stainless Steel.
1) Finish: No. 2B.
Type: Strip seal.
a. Primary seal Material: Santoprene.
1) Color: Black.
b. Wing seal Material: PVC
1) Color: Black
Attachment Method: Mechanical anchors.
Fire-Resistance Rating: Provide joint system and fire-barrier assembly with a rating not less than that of
adjacent.
FINISHES
A.
Comply with NAAMM's "Metal Finishes Manual for Architectural and Metal Products" for recommendations for
applying and designating finishes.
B.
Protect mechanical finishes on exposed surfaces from damage by applying a strippable, temporary protective
covering before shipping.
C.
Appearance of Finished Work: Noticeable variations in same piece are not acceptable.
PART 3 - EXECUTION
3.01
A.
EXAMINATION
Examine surfaces and blockouts where architectural joint systems will be installed for installation tolerances and
other conditions affecting performance of work.
1.
3.02
Proceed with installation only after unsatisfactory conditions have been corrected.
PREPARATION
A.
Prepare substrates according to architectural joint system manufacturer's written instructions.
B.
Repair concrete slabs and blockouts using manufacturer's recommended repair grout of compressive strength
adequate for anticipated structural loadings.
C.
Coordinate and furnish anchorages, setting drawings, and instructions for installing joint systems. Provide
fasteners of metal, type, and size to suit type of construction indicated and to provide for secure attachment of
joint systems.
D.
Cast-In Frames: Coordinate and furnish frames to be cast into concrete.
3.03
INSTALLATION
A.
Comply with manufacturer's written instructions for storing, handling, and installing architectural joint
assemblies and materials unless more stringent requirements are indicated.
B.
Metal Frames: Perform cutting, drilling, and fitting required to install joint systems.
© Copyright 2011 Construction Specialties, Inc.
V 4-11
8.29
1.
2.
3.
4.
5.
6.
7.
C.
Install in true alignment and proper relationship to joints and adjoining finished surfaces measured from
established lines and levels.
Adjust for differences between actual structural gap and nominal design gap due to ambient temperature at
time of installation. Notify Architect where discrepancies occur that will affect proper joint installation and
performance.
Cut and fit ends to accommodate thermal expansion and contraction of metal without buckling of frames.
Locate in continuous contact with adjacent surfaces.
Standard-Duty Systems: Shim to level where required. Support underside of frames continuously to
prevent vertical deflection when in service.
Heavy-Duty Systems: Repair or grout blockout as required for continuous frame support and to bring frame
to proper level. Shimming is not allowed.
Locate anchors at interval recommended by manufacturer, but not less than 3 inches from each end and
not more than 24 inches o.c.
Seals in Metal Frames: Install elastomeric seals and membranes in frames to comply with manufacturer's
written instructions. Install with minimum number of end joints.
1.
2.
3.
Provide in continuous lengths for straight sections.
Seal transitions according to manufacturer's written instructions. Vulcanize or heat-weld field-spliced joints
as recommended by manufacturer.
Installation: Mechanically lock seals into frames or adhere to frames with adhesive or pressure-sensitive
tape as recommended by manufacturer.
D.
Compression Seals: Apply adhesive or lubricant adhesive as recommended by manufacturer before installing
compression seals.
E.
Terminate exposed ends of joint assemblies with field- or factory-fabricated termination devices.
F.
Fire-Resistance-Rated Assemblies: Coordinate installation of architectural joint assembly materials and associated
work so complete assemblies comply with assembly performance requirements.
1.
G.
3.04
Fire Barriers: Install fire barriers to provide continuous, uninterrupted fire resistance throughout length of
joint, including transitions and field splices.
Water Barrier: Provide water barrier at exterior joints and where called for on Drawings. Provide drainage fittings
where indicated.
PROTECTION
A.
Do not remove protective covering until finish work in adjacent areas is complete. When protective covering is
re moved, clean exposed metal surfaces to comply with manufacturer's written instructions.
B.
Protect the installation from damage by work of other Sections. Where necessary due to heavy construction traffic,
remove and properly store cover plates or seals and install temporary protection over joints. Reinstall cover plates
or seals prior to Substantial Completion of the Work.
To download detail, specs & photos visit www.c-sgroup.com
For technical and design assistance call 800-233-8493.
8.30
Download