SECTION 05 0513 SHOP-APPLIED METAL FINISHES This section includes editing notes to assist the user in editing the section to suit project requirements. These notes are included as hidden text, and can be revealed or hidden by one of the following methods: Microsoft Word 2010: Display the FILE tab on the ribbon, click OPTIONS, then on left menu click on DISPLAY. Under ALWAYS SHOW THESE select or deselect HIDDEN TEXT. Microsoft Word 2007: Click the OFFICE button, select WORD OPTIONS, select DISPLAY, then select or deselect the HIDDEN TEXT option. Corel WordPerfect: From the pull-down menus select VIEW, then select or deselect the HIDDEN TEXT option. PART 1 1.1 1.2 SUMMARY A. Section Includes: 1. Shop-applied organic coatings for steel [roof] [and] [wall] panels. B. Related Sections: 1. Division 01: Administrative, procedural, and temporary work requirements. 2. Section [07 7413 - Metal Roof Panels:] [__ ____ - _______:] Steel roof panels to receive shop-applied finishes. 3. Section [07 7423 - Metal Wall Panels:] [__ ____ - _______:] Steel wall panels to receive shop-applied finishes. 4. Section [07 4213.19] [__ ____ - _______:] Insulated steel wall panels to receive shop-applied finishes. REFERENCES A. 1.3 GENERAL ASTM International (ASTM): 1. A653/A653M - Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy Coated (Galvannealed) by the Hot-Dip Process. 2. A792/A792M - Standard Specification for Steel Sheet, 55% Aluminum-Zinc Alloy-Coated by the Hot-Dip Process. 3. D523 - Standard Test Method for Specular Gloss. 4. D2244 - Standard Practice for Calculation of Color Tolerances and Color Differences from Instrumentally Measured Color Coordinates. 5. D2794 - Standard Test Method for Resistance of Organic Coatings to the Effects of Rapid Deformation (Impact). 6. D3276 - Standard Guide for Painting Inspectors (Metal Substrates). 7. D4145 - Standard Test Method for Coating Flexibility of Prepainted Sheet. 8. D4515 - Standard Practice for Estimation of Holding Time for Water Samples Containing Organic Constituents. 9. D4585 - Standard Practice for Testing Water Resistance of Coatings Using Controlled Condensation. SUBMITTALS A. Submittals for Review: 1. Product Data: Manufacturer’s descriptive data and test results for specified finishes. 2. Samples: [3 x 3] [__ x __] inch coating samples [showing available colors] [in specified color] on representative backing. B. Closeout Submittals: ArcelorMittal Dofasco 09/19/13 05 0513-1 Shop-Applied Metal Finishes 1. 1.4 1.5 DELIVERY, STORAGE AND HANDLING A. Apply manufacturer’s standard protective coverings to finished surfaces. B. Deliver, store, and handle finished components in manner to prevent damage to finishes. WARRANTIES A. PART 2 2.1 2.2 2.4 Furnish manufacturer’s 25 year limited warranty providing coverage for paint film integrity. PRODUCTS MANUFACTURERS A. Contract Documents are based on products by ArcelorMittal Dofasco, Box 2460, 1330 Burlington Street, East Hamilton, ON L8N 3J5 Canada, 1-800-816-6333, dofasco@arcelormittal.com, www.arcelormittal.com. B. Substitutions: [Under provisions of Division 01.] [Not permitted.] MATERIALS A. 2.3 Maintenance Data: Provide information regarding touch-up, cleaning, and maintenance of finishes. Organic Coating: 1. Product: Solano. 2. Description: Plasticol organic coating, non toxic, phthalate-free and heavy-metal free topcoat pain system. 3. Physical attributes: a. Gloss; tested to ASM D523 at 60 degrees: 1) Un-embossed: 25 to 35 gloss units. 2) Embossed: Less than 30 gloss units. b. Adhesion (T-bend): 1T; no tape removal, tested to ASTM D4515. c. Flexibility (T-bend): 3T, no cracks, tested to ASTM D4145. d. Adhesion impact: No cracking or loss of adhesion, tested to ASTM D2794 at 160 inch-pounds. e. Humidity condensation: No blisters larger than No. 8, tested to ASTM D4585. 4. Performance requirements: a. Film integrity: 25 years, no peeling, cracking, blistering, or flaking. b. Color change: 20 years, maximum Delta E8, wall or roof, tested to ASTM D2244. 5. Color: [____.] [To be selected from manufacturer's full color options.] APPLICATION A. Substrate: Metallic-coated steel sheet, hot-dip galvanized to ASTM A653/A653M or aluminum-zinc alloy coated to ASTM A792/A792M. B. Surface Preparation: Pretreat surfaces to receive coatings to coating manufacturer’s requirements. C. Application: Apply coatings in accordance with manufacturer’s instructions to uniform surface free from blemishes. D. Minimum Coating Dry Film Thickness: [4] [8] mils, tested to ASTM D3276. E. Curing: After application, cure coatings in accordance with manufacturer’s recommended cure schedule including cure temperature and cure time. FABRICATION Shop-Applied Metal Finishes 05 0513-2 ArcelorMittal Dofasco 09/19/13 A. PART 3 3.1 Touch up minor scratches and abrasions in finishes in accordance with manufacturer’s instructions; replace components having damage that cannot be successfully touched up. CLEANING A. 3.3 EXECUTION ADJUSTING A. 3.2 Follow coating manufacturer's instructions for cold roll-forming, stamping, and press braking of coated steel sheet. Clean finished surfaces after installation in accordance with manufacturer’s instructions. SCHEDULE COMPONENT COLOR Metal Roof Panels Hunters Green 60020 Metal Wall Panels Fossil Grey 60026 END OF SECTION ArcelorMittal Dofasco 09/19/13 05 0513-3 Shop-Applied Metal Finishes