New Document

advertisement
TRUGROOVE CONTINUOUS
DEFINITION LED
DIRECT DEFINITION, FLUSH SILK LENS
CRI >80 4000K, 3000 lm/4ft
Project:
Spec Type:
Catalog No: 39C0LAEL
Qty
Line Notes:
Ordering guide
Product Type
Source
Color Temp *
Lumens *
Optics
Housing
39C0
L
A
E
L
S
TruGroove
Continuous
Definition LED
L
LED
A 4000K
B 3500K
C 3000K
E 3000 lm/4ft
G 2200 lm/4ft
K 1500 lm/4ft
L Flush Silk Lens
M Regressed Silk
Lens
S Standard
C Chicago Plenum
Ceiling / Trim
1 T-Grid
4 Drywall Trim
3 Drywall Trimless
Run Length
Wiring
1 1 cct
Specify total
housing run length 3 1 cct w/ EM cct
in feet and inches 5 1 cct w/ BP
7 1 cct w/ Dimming
8 1 cct w/ TW
B 2 cct A/B
Voltage
1 120V
2 277V
3 347V
Driver
E Standard
* Nominal values within a range. Consult ies file for exact color temp and lumens † Consult website for complete list of standard wiring options
Mounting Hardware
Recessed
Mount Type
Consult separate mounting spec sheet for mount type options
Integrated Controls Please indicate with check mark.
No Options Available
© 2014 Koninklijke Philips N.V. All rights reserved.
Specifications are subject to change without notice.
www.philips.com/luminaires
39C0LAEL.pdf 04.15 page 1 of 4
TRUGROOVE CONTINUOUS
DEFINITION LED
DIRECT DEFINITION, FLUSH SILK LENS
Photometry
180
135
135
90
90
1100 cd
45
45
0
0% Up / 100% Down
0
45
90
Values per 4ft unit
Total Output
3000 lm
Efficacy
71.8 lm/W
CCT
4058K
CRI
84
R9
17
Distribution
0% Up / 100% Down
Spacing Criteria (0/90/180°)
1.27/1.26/NA
Candela Distribution
Vertical
Angle
0
5
15
25
35
45
55
65
75
85
90
95
105
115
125
135
145
155
165
175
180
0
1032
1028
999
931
833
707
557
387
206
42
0
0
0
0
0
0
0
0
0
0
0
Horizontal Angle
22.5
45
67.5
1032 1032 1032
1022 1026 1030
989
997
997
923
929
925
827
829
827
703
705
699
555
553
547
385
381
377
204
202
200
42
40
42
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Fixture photometry has been
conducted by an NVLAP accredited
testing laboratory in accordance with
IESNA LM-79:2008
Lumen maintenance of the LEDs has
been tested by the manufacturer in
accordance with IESNA LM-80:2008
Coefficients of Utilization (%)
90
1032
1026
995
925
823
697
547
377
200
40
0
0
0
0
0
0
0
0
0
0
0
Zonal
Lumens
0
98
281
427
518
541
493
378
214
51
0
0
0
0
0
0
0
0
0
0
0
RCR
0
1
2
3
4
5
6
7
8
9
10
Vertical
Angle
55
65
75
85
Input Voltage
120V
277V
Input Power
41.8W
41.4W
Input Current
0.4A
0.2A
Power Factor
0.988
Total Harm. Distortion
13.7%
Tested values – contact technical support for rated values.
Off-state power zero unless certain controls are specified.
39C0LAEL.pdf 04.15 page 2 of 4
Ceiling:
Wall:
70
119
109
99
90
82
76
70
65
60
56
53
50
119
104
90
79
70
63
56
51
46
43
39
80
30
119
100
83
71
61
53
47
42
38
34
31
10
119
96
78
64
54
47
41
36
32
29
26
70
116
106
96
87
80
73
68
63
59
55
51
Avg. Luminance (cd/m2)
Electrical Specifications
© 2014 Koninklijke Philips N.V. All rights reserved.
Specifications are subject to change without notice.
www.philips.com/luminaires
IES files for this and other
photometric options can be
downloaded online at
www.lightingproducts.philips.com
0
10675
10074
8733
5288
Horizontal Angle
45
90
10598
10483
9918
9814
8564
8479
5036
5036
70
50
116
102
88
78
69
61
55
50
46
42
39
30
116
98
82
70
60
53
47
42
38
34
31
50
111
97
85
75
66
59
53
49
44
41
38
50
30
111
94
80
68
59
52
46
41
37
34
31
10
111
91
75
63
53
46
40
35
32
28
26
0
0
100
84
69
58
50
43
37
33
29
26
24
TRUGROOVE CONTINUOUS
DEFINITION LED
Modules & Runs
TruGroove Continuous LED nominal housing lengths
2ft, 3ft, 4ft, 8ft & incremental units.
Standard units allow runs specifiable from 2ft in 1ft steps.
Incremental units allow run lengths from 3ft in increments as small as 1/8in*.
*Note: Asymmetric and E lumen package versions (3000lm/4ft) are only available in 2ft increments.
Module Dimensions
© 2014 Koninklijke Philips N.V. All rights reserved.
Specifications are subject to change without notice.
www.philips.com/luminaires
39C0LAEL.pdf 04.15 page 3 of 4
Flush lens trimless versions can be installed in either the wall or ceiling.
To ensure full cavity closure and simplify installation, there are both end-run units with one closed end and
mid-run, open units.
Refer to module size details below for actual dimensions e.g. trim. T-grid units fit within a standard 2' grid.
To specify corners and patterns, refer to TruGroove Corners data sheets.
TRUGROOVE CONTINUOUS
DEFINITION LED
Options and Details
Trim Views
Housing
Mounting
Die-formed 20 gauge cold-rolled steel. Multiple upper wire
entrances available for continuous row mounting of fixtures.
Maximum 3.5lb/ft.
Mounting brackets on housing sides support T-Grid installation. 1/
16” diameter aircraft cable with self-locking, tamper-resistant,
miniature cable gripper provides vertical adjustment for drywall.
Aircraft cable, crimp and gripper independently tested to meet
stringent safety requirements.
Optical System
Joints
Performance version: White light emitted from the LED sources is
internally reflected and laterally redirected by a biconvex lens. Light is
then reflected by Miro Silver panels and exits through the optical
lens assembly. This assembly contains acrylic extrusion profiles to
retain a layer of MesoOptics film, creating both an uninterrupted
continuum of light and an optical batwing distribution.
Self-aligning joining system with hands-free pre-joining wire access.
Weight
Definition version: Light passes through a diffuse white acrylic lens to
deliver a highly uniform luminous continuum.
Standard Driver
Dimming: 0-10V, 5-100%. Output is Class 2 rated.
Lumen Maintenance
At an ambient temperature of 25°C in non-insulated contact
applications, the LED lumen maintenance expectation for each
lumen package is:
K: L80 (12k) 71,000 hrs
G: L80 (12k) 68,000 hrs
E: L80 (12k) 54,000 hrs
Electrical
Factory pre-wired to section ends with quick-wire connectors.
Approvals
Certified to UL, CSA and IES standards. Insulation Contact (IC)
rated.
Finish
Extruded aluminum trim and die-cast endplates coated with
electrostatically applied and thermally cured polyester powder coat
paint finish.
Environment
Rated for dry or damp locations in operating ambient temperatures
0-40°C (32-104°F). Certain luminaire components may be
adversely affected by contaminants. Damage caused by sulfur,
chlorine, petroleum based solutions or other contaminants are not
covered under warranty.
Due to continuing product improvements, Philips Ledalite reserves the right to change the specifications without notice.
© 2014 Koninklijke Philips N.V. All rights reserved.
Specifications are subject to change without notice.
www.philips.com/luminaires
39C0LAEL.pdf 04.15 page 4 of 4
Philips Lighting
North America Corporation
200 Franklin Square Drive
Somerset, NJ 08873
Phone: 855-486-2216
Download