RIB® Emergency Lighting and Power Equipment Relays with Remote Test Capability IMPORTANT SAFEGUARD: INSULATE UNUSED LEADS INDIVIDUALLY When using electrical equipment, basic safety precautions should always be followed including the following: www.FunctionalDevices.com | 800.888.5538 UL924 Emergency Lighting and Power Equipment Bulletin B1179 393106B 33PE ESRT READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. Do not use outdoors. 2. Do not mount near gas or electric heaters. 3. Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel. 4. The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition. 5. Do not use equipment for other than intended use. 6. Servicing of this equipment should be performed by a qualified service personnel. SAVE THESE INSTRUCTIONS. Wireless Key Fob Transmitter Remote Tester for Use with Radio Frequency-Enabled UL924 Emergency Bypass / Shunt Relays Remote Testing of Emergency Lighting Emergency Emergency Lighting Lighting ESRT ESRT ESR2401B-RF ESR2402B-RF Emergency Emergency Power Power Specifications Battery: Expected Battery Life: Operate Time: Dimensions: Frequency: Radio Certifications: CR2032, 3V, Lithium 2 years 500 mS 2.30˝ x 1.40˝ x .50˝ 315 MHz FCC Part 15 (USA), IC (Canada) Notes: » Control one or more radio frequency-enabled ESR relays with a single transmitter » Typical transmission distance: Up to 50 feet indoors Emergency Emergency Transfer Transfer Yel Yel SW SW Coil Coil Blu Blu Normal Normal Power Power RF-Enabled UL924 Relays ESR2401B-RF, ESR2402B-RF, ESRE01C-RF, ESRE277C-RF Turn wall switch (SW) to OFF position Press button on ESRT to turn Emergency Lighting ON Emergency Lighting will remain ON for 7-10 seconds, and then will turn OFF RIB® Emergency Lighting and Power Equipment Relays with Remote Test Capability ESR2401B-RF ^ Wht/Blk 120 Vac Blu N/C Wht/Blu 24 Vac/dc Yel Comm ESRE01C-RF^ Blk Utility 120 Vac ESR2402B-RF ^ Wht/Brn 208-277 Vac Blu N/C Wht/Blu 24 Vac/dc Yel Comm COIL INPUT RATINGS 24 Vdc @ 50 mA max 30 Vdc @ 60 mA max 24 Vac @ 83 mA max 120 Vac @ 60 mA max Org N/O Wht/Yel Comm CONTACT RATINGS 20 A Resistive, 277 Vac 20 A Ballast N/O, 120/277 Vac 10 A Ballast N/C, 120/277 Vac 10 A Tungsten N/O, 120 Vac 2 A Tungsten N/C, 120 Vac 1 HP, 120 Vac 2 HP, 277 Vac 770VA Pilot Duty, 120Vac 1110VA Pilot Duty, 277Vac Wht/Yel Comm Blu Switched Hot to Load Yel Emergency Hot Wht Utility Neutral Gry Emergency Neutral CONTACT RATINGS 3 Amp Ballast @ 120/277 Vac COIL INPUT RATINGS 120 Vac @ 50 mA max Blk Utility 277 Vac Yel Emergency Hot Wht Utility Neutral Gry Emergency Neutral Example Wiring for ESR2402B-RF Emergency Lighting Transfer Switch ESR2402B-RF 208-277 Vac 208-277 Vac Emergency Circuit Breaker Panel Hot Wht/Brn Neutral Wht/Yel Light Switch Hot Blu Yel Neutral Emergency Power ie. Generator/ Battery Backup UL924 Emergency Lighting and Power Equipment Blu Switched Hot to Load Prp Switched 277 Vac NOTES ^FOR SUPPLY CONNECTIONS USE #12AWG WIRES OR LARGER RATED FOR AT LEAST 75°C(167°F). Normal Circuit Breaker Panel COIL INPUT RATINGS 24 Vdc @ 50 mA max 30 Vdc @ 60 mA max 24 Vac @ 83 mA max 208-277 Vac @ 75 mA max ESRE277C-RF^ Prp Switched 120 Vac Normal Power Org N/O CONTACT RATINGS 20 A Resistive, 277 Vac 20 A Ballast N/O, 120/277 Vac 10 A Ballast N/C, 120/277 Vac 10 A Tungsten N/O, 120 Vac 2 A Tungsten N/C, 120 Vac 1 HP, 120 Vac 2 HP, 277 Vac 770VA Pilot Duty, 120Vac 1110VA Pilot Duty, 277Vac CONTACT RATINGS 3 Amp Ballast @ 120/277 Vac COIL INPUT RATINGS 277 Vac @ 40 mA max