PRODUCT DATASHEET ICA12-50JPL 1/2" ClearFill®Line Plenum-Rated Air-Dielectric Coaxial Cable for InBuilding Applications ClearFill®Line 1/2" low loss air dielectric cable, Plenum-rated, CMP FEATURES / BENEFITS Supports Multiple RF Signals Complete Shielding The solid outer conductor of the ClearFill®Line coaxial cable creates a continuous RFI/EMI shield that minimizes system interference. Outstanding Intermodulation Performance RFS coaxial cable's solid inner and outer conductors virtually eliminate intermods. Intermodulation performance is also confirmed with state-of-the-art equipment at the RFS factory. Wide Range of Applications Typical areas of application are: feedlines for plenum-space installations within occupied buildings or structures. 1/2" Plenum-Rated In-Building Cable Technical Features APPLICATIONS Applications Plenum In-Building STRUCTURE Cable Type Size Inner Conductor Dielectric Outer Conductor Jacket mm (in) mm (in) mm (in) mm (in) Air-Dielectric, Corrugated 1/2" 4.8 (0.19) Copper-Clad Aluminum Wire 11.8 (0.464) Extruded Polyethylene 13.8 (0.54) Corrugated Copper 15.93 (0.627) Plenum Rated / color blue ELECTRICAL SPECIFICATIONS ȍ GHz % pF/m (pF/ft) µH/m (µH/ft) kW Volts Volt RMS ȍm ȍft) ȍm ȍft) Impedance Maximum Frequency Velocity Capacitance Inductance Peak Power Rating RF Peak Voltage Jacket Spark Inner Conductor dc Resistance Outer Conductor dc Resistance Return Loss (VSWR) Performance Maximum Return Loss Temperature & Power dB (VSWR) 50 +/- 1 6 91 76 (23.2) 0.19 (0.058) 40 2000 8000 1.48 (0.45) 1.9 (0.58) 24.3 (1.13) @ 698-960 MHz 24.3 (1.13) @ 1700-2155 MHz 18 (1.29) @ 4400-5900 MHz 19 (1.25) in other specified bands High Power Rating MECHANICAL SPECIFICATIONS Cable Weight Minimum Bending Radius, Single Bend Minimum Bending Radius, Repeated Bends Bending Moment Tensile Strength Recommended / Maximum Clamp Spacing ICA12-50JPL REV: G kg/m (lb/ft) mm (in) mm (in) Nm (lb*ft) N (lb) m (ft) 0.37 (0.25) 125 (5) 254 (10) 4.1 (3) 1112 (250) 0.5 / 0.9 (1.8 / 3) REV DATE: 21.Jun.2016 All values nominal unless tolerances provided; information contained in the present datasheet is subject to confirmation at time of ordering www.rfsworld.com Page 1 of 2 PRODUCT DATASHEET ICA12-50JPL 1/2" ClearFill®Line Plenum-Rated Air-Dielectric Coaxial Cable for InBuilding Applications ATTENUATION AND POWER RATING Frequency MHz 0.5 1 1.5 2 10 20 30 50 88 100 108 150 174 200 300 400 450 500 512 600 700 750 800 824 894 900 925 960 1000 1250 1400 1500 1700 1800 2000 2100 2200 2300 2400 2500 2600 2700 3000 3500 3600 4000 4500 5000 5500 6000 Attenuation dB/100m dB/100ft 0.15 0.045 0.21 0.064 0.26 0.079 0.30 0.091 0.67 0.204 0.95 0.291 1.17 0.358 1.52 0.465 2.04 0.622 2.18 0.665 2.27 0.692 2.70 0.822 2.92 0.889 3.14 0.957 3.89 1.19 4.54 1.39 4.84 1.48 5.13 1.56 5.19 1.58 5.66 1.73 6.16 1.88 6.40 1.95 6.64 2.02 6.75 2.06 7.06 2.15 7.08 2.16 7.19 2.19 7.34 2.24 7.51 2.29 8.52 2.60 9.08 2.77 9.45 2.88 10.20 3.09 10.50 3.20 11.20 3.40 11.50 3.50 11.80 3.59 12.10 3.69 12.40 3.78 12.70 3.87 13.00 3.96 13.30 4.05 14.10 4.31 15.50 4.73 15.80 4.81 16.80 5.13 18.10 5.51 19.30 5.88 20.40 6.23 21.60 6.58 Power kW 40.00 34.30 27.90 24.20 10.70 7.55 6.15 4.74 3.53 3.30 3.17 2.67 2.47 2.30 1.85 1.59 1.49 1.41 1.39 1.28 1.17 1.13 1.09 1.07 1.02 1.02 1.01 0.986 0.964 0.851 0.799 0.768 0.713 0.693 0.65 0.633 0.618 0.603 0.588 0.575 0.562 0.549 0.519 0.474 0.465 0.438 0.408 0.383 0.364 0.344 TESTING AND ENVIRONMENTAL Fire Performance Flame Retardant Jacket Specifications Regulatory Compliance Installation Temperature Storage Temperature Operation Temperature Flame Retardant, Plenum Rated Meets/Exceeds Steiner Tunnel Test Method UL 910, NEC 82053 (a) CMP, NFPA-262. NEC Article 800 Communication Circuits ETL Listed to UL444 Canadian CSA C.22.2/FT6 -20 to 60 (-4 to 140) °C(°F) -40 to 85 (-40 to 185) °C(°F) -40 to 85 (-40 to 185) °C(°F) Attenuation at 20°C (68°F) cable temperature; tolerance +/- 5% max.; Mean power rating at 40°C (104°F) ambient temperature External Document Links ICA12-50JPL Notes REV: G REV DATE: 21.Jun.2016 All values nominal unless tolerances provided; information contained in the present datasheet is subject to confirmation at time of ordering www.rfsworld.com Page 2 of 2