PRODUCT DATASHEET
ICA12-50JPL
1/2" ClearFill®Line Plenum-Rated Air-Dielectric Coaxial Cable for InBuilding Applications
ClearFill®Line 1/2" low loss air dielectric cable, Plenum-rated, CMP
FEATURES / BENEFITS
Supports Multiple RF Signals
Complete Shielding
The solid outer conductor of the ClearFill®Line coaxial cable creates a continuous RFI/EMI shield
that minimizes system interference.
Outstanding Intermodulation Performance
RFS coaxial cable's solid inner and outer conductors virtually eliminate intermods. Intermodulation
performance is also confirmed with state-of-the-art equipment at the RFS factory.
Wide Range of Applications
Typical areas of application are: feedlines for plenum-space installations within occupied buildings or
structures.
1/2" Plenum-Rated In-Building Cable
Technical Features
APPLICATIONS
Applications
Plenum In-Building
STRUCTURE
Cable Type
Size
Inner Conductor
Dielectric
Outer Conductor
Jacket
mm (in)
mm (in)
mm (in)
mm (in)
Air-Dielectric, Corrugated
1/2"
4.8 (0.19) Copper-Clad Aluminum Wire
11.8 (0.464) Extruded Polyethylene
13.8 (0.54) Corrugated Copper
15.93 (0.627) Plenum Rated / color blue
ELECTRICAL SPECIFICATIONS
ȍ
GHz
%
pF/m (pF/ft)
µH/m (µH/ft)
kW
Volts
Volt RMS
ȍm ȍft)
ȍm ȍft)
Impedance
Maximum Frequency
Velocity
Capacitance
Inductance
Peak Power Rating
RF Peak Voltage
Jacket Spark
Inner Conductor dc Resistance
Outer Conductor dc Resistance
Return Loss (VSWR) Performance
Maximum Return Loss
Temperature & Power
dB (VSWR)
50 +/- 1
6
91
76 (23.2)
0.19 (0.058)
40
2000
8000
1.48 (0.45)
1.9 (0.58)
24.3 (1.13) @ 698-960 MHz
24.3 (1.13) @ 1700-2155 MHz
18 (1.29) @ 4400-5900 MHz
19 (1.25) in other specified bands
High Power Rating
MECHANICAL SPECIFICATIONS
Cable Weight
Minimum Bending Radius, Single Bend
Minimum Bending Radius, Repeated Bends
Bending Moment
Tensile Strength
Recommended / Maximum Clamp Spacing
ICA12-50JPL
REV: G
kg/m (lb/ft)
mm (in)
mm (in)
Nm (lb*ft)
N (lb)
m (ft)
0.37 (0.25)
125 (5)
254 (10)
4.1 (3)
1112 (250)
0.5 / 0.9 (1.8 / 3)
REV DATE: 21.Jun.2016
All values nominal unless tolerances provided; information contained in the present datasheet is subject to confirmation at time of ordering
www.rfsworld.com
Page 1 of 2
PRODUCT DATASHEET
ICA12-50JPL
1/2" ClearFill®Line Plenum-Rated Air-Dielectric Coaxial Cable for InBuilding Applications
ATTENUATION AND POWER RATING
Frequency
MHz
0.5
1
1.5
2
10
20
30
50
88
100
108
150
174
200
300
400
450
500
512
600
700
750
800
824
894
900
925
960
1000
1250
1400
1500
1700
1800
2000
2100
2200
2300
2400
2500
2600
2700
3000
3500
3600
4000
4500
5000
5500
6000
Attenuation
dB/100m dB/100ft
0.15
0.045
0.21
0.064
0.26
0.079
0.30
0.091
0.67
0.204
0.95
0.291
1.17
0.358
1.52
0.465
2.04
0.622
2.18
0.665
2.27
0.692
2.70
0.822
2.92
0.889
3.14
0.957
3.89
1.19
4.54
1.39
4.84
1.48
5.13
1.56
5.19
1.58
5.66
1.73
6.16
1.88
6.40
1.95
6.64
2.02
6.75
2.06
7.06
2.15
7.08
2.16
7.19
2.19
7.34
2.24
7.51
2.29
8.52
2.60
9.08
2.77
9.45
2.88
10.20
3.09
10.50
3.20
11.20
3.40
11.50
3.50
11.80
3.59
12.10
3.69
12.40
3.78
12.70
3.87
13.00
3.96
13.30
4.05
14.10
4.31
15.50
4.73
15.80
4.81
16.80
5.13
18.10
5.51
19.30
5.88
20.40
6.23
21.60
6.58
Power
kW
40.00
34.30
27.90
24.20
10.70
7.55
6.15
4.74
3.53
3.30
3.17
2.67
2.47
2.30
1.85
1.59
1.49
1.41
1.39
1.28
1.17
1.13
1.09
1.07
1.02
1.02
1.01
0.986
0.964
0.851
0.799
0.768
0.713
0.693
0.65
0.633
0.618
0.603
0.588
0.575
0.562
0.549
0.519
0.474
0.465
0.438
0.408
0.383
0.364
0.344
TESTING AND ENVIRONMENTAL
Fire Performance
Flame Retardant Jacket Specifications
Regulatory Compliance
Installation Temperature
Storage Temperature
Operation Temperature
Flame Retardant, Plenum Rated
Meets/Exceeds Steiner Tunnel Test Method UL 910, NEC 82053 (a) CMP, NFPA-262.
NEC Article 800 Communication Circuits
ETL Listed to UL444
Canadian CSA C.22.2/FT6
-20 to 60 (-4 to 140) °C(°F)
-40 to 85 (-40 to 185) °C(°F)
-40 to 85 (-40 to 185) °C(°F)
Attenuation at 20°C (68°F) cable temperature;
tolerance +/- 5% max.; Mean power rating at
40°C (104°F) ambient temperature
External Document Links
ICA12-50JPL
Notes
REV: G
REV DATE: 21.Jun.2016
All values nominal unless tolerances provided; information contained in the present datasheet is subject to confirmation at time of ordering