PRODUCT DATASHEET
LCF78-50JA-A0
7/8" CELLFLEX® Premium Attenuation Low-Loss Foam-Dielectric
Coaxial Cable
CELLFLEX®7/8" premium attenuation low loss flexible cable
FEATURES / BENEFITS
Ultra Low Attenuation
The further reduced attenuation of CELLFLEX® premium attenuation coaxial cable results in extremly
efficient signal transfer in your RF system, especially at high frequencies.
Complete Shielding
The solid outer conductor of CELLFLEX® coaxial cable creates a continuous RFI/EMI shield that
minimizes system interference.
Low VSWR
Special low VSWR versions of CELLFLEX® coaxial cables contribute to low system noise.
Outstanding Intermodulation Performance
CELLFLEX® coaxial cable's solid inner and outer conductors virtually eliminate intermods.
Intermodulation performance is also confirmed with state-of-the-art equipment at the RFS factory.
High Power Rating
Due to their low attenuation, outstanding heat transfer properties and temperature stabilized dielectric
materials, CELLFLEX® cable provides safe long term operating life at high transmit power levels.
Wide Range of Application
Typical areas of application are: feedlines for broadcast and terrestrial microwave antennas, wireless
cellular, PCS and ESMR base stations, cabling of antenna arrays, and radio equipment interconnects.
7/8" CELLFLEX® Low-Loss Foam
Dielectric Coaxial Cable
Technical Features
APPLICATIONS
Applications
Main feed line
STRUCTURE
Cable Type
Size
Jacket Option
Inner Conductor
Dielectric
Outer Conductor
Jacket
mm (in)
mm (in)
mm (in)
mm (in)
Foam-Dielectric, Corrugated
7/8"
Black
9.32 (0.37) Copper Tube
22.4 (0.88) Foam Polyethylene
25.2 (0.99) Corrugated Copper
27.8 (1.09) Polyethylene, PE
ELECTRICAL SPECIFICATIONS
ȍ
GHz
%
pF/m (pF/ft)
µH/m (µH/ft)
kW
Volts
Volt RMS
ȍm ȍft)
ȍm ȍft)
Impedance
Maximum Frequency
Velocity
Capacitance
Inductance
Peak Power Rating
RF Peak Voltage
Jacket Spark
Inner Conductor dc Resistance
Outer Conductor dc Resistance
Return Loss (VSWR) Performance
Maximum Return Loss
Phase Stabilized
Temperature & Power
dB (VSWR)
50 +/- 1
5
90
74 (22.5)
0.185 (0.056)
85
2920
8000
1.54 (0.47)
1.55 (0.47)
Standard
24 (1.135)
Phase stabilized and phase matched cables and assemblies are available upon request.
Standard
MECHANICAL SPECIFICATIONS
Cable Weight
Minimum Bending Radius, Single Bend
Minimum Bending Radius, Repeated Bends
Bending Moment
Tensile Strength
Recommended / Maximum Clamp Spacing
LCF78-50JA-A0
REV: D
kg/m (lb/ft)
mm (in)
mm (in)
Nm (lb*ft)
N (lb)
m (ft)
0.41 (0.28)
120 (5)
250 (10)
13 (9.6)
1440 (324)
0.8 / 1 (2.75 / 3.25)
REV DATE: 11.Dec.2013
All values nominal unless tolerances provided; information contained in the present datasheet is subject to confirmation at time of ordering
www.rfsworld.com
Page 1 of 2
PRODUCT DATASHEET
LCF78-50JA-A0
7/8" CELLFLEX® Premium Attenuation Low-Loss Foam-Dielectric
Coaxial Cable
ATTENUATION AND POWER RATING
Frequency
MHz
0.5
1
1.5
2
10
20
30
50
88
100
108
150
174
200
300
400
450
500
512
600
700
750
800
824
894
900
925
960
1000
1250
1400
1500
1700
1800
2000
2100
2200
2400
2500
2600
2700
3000
3500
4000
4900
5000
Attenuation
dB/100m dB/100ft
0.08
0.024
0.11
0.034
0.14
0.041
0.16
0.048
0.35
0.107
0.50
0.152
0.61
0.186
0.79
0.242
1.06
0.323
1.13
0.345
1.18
0.358
1.39
0.425
1.50
0.458
1.62
0.493
2.00
0.608
2.32
0.707
2.47
0.753
2.61
0.796
2.64
0.806
2.88
0.876
3.12
0.951
3.24
0.987
3.35
1.02
3.41
1.04
3.56
1.08
3.57
1.09
3.62
1.10
3.70
1.13
3.78
1.15
4.27
1.30
4.54
1.38
4.71
1.44
5.05
1.54
5.21
1.59
5.52
1.68
5.67
1.73
5.82
1.77
6.11
1.86
6.25
1.91
6.39
1.95
6.53
1.99
6.93
2.11
7.56
2.30
8.16
2.49
9.17
2.80
9.28
2.83
Power
kW
85.00
85.00
73.60
63.70
28.30
20.00
16.20
12.50
9.38
8.80
8.42
7.15
6.63
6.14
4.97
4.28
4.02
3.81
3.77
3.45
3.19
3.07
2.97
2.91
2.79
2.78
2.75
2.69
2.63
2.33
2.19
2.11
1.97
1.91
1.80
1.75
1.71
1.63
1.59
1.56
1.52
1.43
1.31
1.22
1.08
1.07
TESTING AND ENVIRONMENTAL
Fire Performance
Installation Temperature
Storage Temperature
Operation Temperature
Halogene Free
-40 to 60 (-40 to 140) °C(°F)
-70 to 85 (-94 to 185) °C(°F)
-50 to 85 (-58 to 185) °C(°F)
Attenuation at 20°C (68°F) cable temperature;
tolerance +/- 5% max.; Mean power rating at
40°C (104°F) ambient temperature
External Document Links
LCF78-50JA-A0
Notes
REV: D
REV DATE: 11.Dec.2013
All values nominal unless tolerances provided; information contained in the present datasheet is subject to confirmation at time of ordering