fnps Enclosed and Gasketed Fiberglass Industrial Severe Locations / 2, 3, or 4-Lamp T5, T8, T12 Project Information Project Name Type Catalog No. Date Housing Electrical One piece, high-impact, molded fiberglass reinforced polyester housing supplied with (2) ½" die cast aluminum hubs. Features • Wet location certified for ceiling and wall mount • Nylon or stainless steel latches available with tamper resistant screws • For use in wet locations where moisture and washdown are prevalent • Up to 40°C ambient suitable • For use in outdoor, hosedown, and corrosive location, and high ambient conditions • IP65 listed for dust-tight, hosedown, and outdoor • UL 1598A marine listed (optional) standard wet location • Accessible drop-down ballast tray • Listed as electrical enclosure for thru-branch wiring • Conduit hubs available in die-cast aluminum or 316 stainless steel • Mounting accessories in stainless or galvanized steel • Ballast backup availability Shielding Standard lens is of 25% DR acrylic material. Higher DR content acrylic and polycarbonate lenses are available as an option. Ballasts Example FNPS4-428-EPU-2H-SSTP – Model – No. of Lamps in Cross Section FNPS Enclosed and Gasketed Fiberglass Industrial Severe Locations Certification All luminaires are built to UL 1598 standards and bear appropriate UL and cUL or CSA labels. Wet location labeling is standard. IP65 rated. Marine UL1598A listing and NFS listing available as options. Energy efficient, thermally protected, automatic resetting, Class P, high power factor, sound rated A, unless otherwise specified. CEE NEMA Premium compliant. Ordering Information FNPS Standard class “P,” thermally protected, autoresetting HPF ballast, sound rated A. CEE NEMA Premium compliant. All ballast leads extend a minimum of 6" through access location. NEC/CECcompliant ballast disconnect is standard. 2 Two 3 Three (4' only) 4 Four (4' only) Lens Blank Acrylic Crepe, 25% DR DR Acrylic Crepe, 100% DR (4', 8' only) PP Prismatic Polycarbonate1 CA Clear Acrylic, 25% DR (4', 8' only) OA Opal Acrylic, 25% DR (4', 8' only) – Voltage U 120V-277V 347 347V Entries Options 2H (2) 1/2" Aluminum Hubs 2HS (2) 1/2" Stainless Steel Hubs 2H3S (2) 3/4" Stainless Steel Hubs 2HMS (2) 20 mm Stainless Steel Hubs2 GLR Fast Blow Fuse TP Tamper Resistant Latches NFS National Sanitation Foundation Listed SSTP Stainless Steel Tamper Resistant Latches MLID Marine Listed, Indoor Drip Proof (lens down) Length Lamp Type Ballast2 4 4' 8 8' 28 4', T5: 28 Watt 32 4', T8: 32, 30, 28, or 25 Watt (2 and 3-Lamp) 48T8HO 4', T8: 44 Watt (2-Lamp only) 59 8', T8: 59 Watt 96T8HO 8', T8: 86 Watt 96HO 8', T12: 110 or 95 Watt E Electronic T8, Instant Start EHL Electronic T8, High Light Output, Instant Start EP Electronic, Programmed Start EP Electronic T12 (96HO only) Programmed Start For a specific ballast vendor, show as options. Wet location ceiling mount only (lens down). Ballasts may not be available in all combinations of lamp/voltage/start temp/THD shown above. 3 20 MM entries not CSA or ABS certified. 4 Fusing not available. 1 2 Page 1/3 Rev. 02/12/13 – Accessories3 (Order Separately) PEBU End Bracket Universal Surface Mount Kit for 2H3S hub option PEBUHSMS End Bracket Universal Surface Mount Kit for 2H and 2HS hub option PTBS Top Bracket Surface Mount, 2 Per Kit, 304 Stainless PTBS3 Top Bracket Surface Mount, 3 Per Kit, 304 Stainless (8 ft only) PTBA Top Bracket Wall/Angle Kit, 2 Per Kit, 304 Stainless TPSD Tamper Resistant Screwdriver Extreme Environment / fnps © 2013 Columbia Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Columbia Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Tech Support 864.678.1668 / Website www.columbialighting.com fnps Enclosed and Gasketed Fiberglass Industrial Severe Locations / 2, 3, or 4-Lamp T5, T8, T12 Photometric Data Test HP08581A Test Date 11/15/00 Luminaire Data Zonal Lumen Summary Zone FNPS4-232-EU FNPS Enclosed and Gasketed 8" × 4' 2-Lamp with acrylic crepe lens E2-32IS-120SC 0.88 F32T8 2850 56 Surface 0º = 90 90º = 90 0º = 1.23 90º = 1.43 Length: 4.08 Width: 0.56 Height: 0.22 Ballast Ballast Factor Lamp Lumens per Lamp Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in Feet 0-30 0-40 0-60 0-90 0-180 Lumens %Lamp 976 1625 2989 4394 4883 Energy Data %Fixt. 17.1 28.5 52.4 77.1 85.7 20.0 33.3 61.2 90.0 100.0 Indoor Candela Plot RCR 70 89 80 72 66 60 56 52 48 45 42 80 50 30 84 79 72 65 62 55 55 47 49 41 44 36 39 32 36 28 33 26 30 23 10 75 60 49 41 35 30 26 23 21 19 70 86 77 69 63 58 53 50 46 43 40 70 50 30 81 77 69 63 60 53 53 46 47 40 42 35 38 31 35 28 32 25 29 23 10 73 58 48 40 34 29 26 23 20 18 50 76 65 57 50 44 40 36 33 30 28 50 30 72 60 51 43 38 33 30 27 24 22 10 69 55 46 38 33 28 25 22 20 18 0 0 60 48 39 33 28 25 22 19 17 15 85.7% Luminaire Efficacy Rating (LER) IESNA RP-1-1993 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens FL-77 Noncompliant $3.12 based on 3000 hrs. and $0.08 per KWH AVG. LUMINANCE (Candela/Sq. M.) Coefficients of Utilization (%) RC RW 1 2 3 4 5 6 7 8 9 10 Total Luminaire Efficiency Average Luminance Angle Luminaire 0 30 40 45 50 55 60 65 70 75 80 85 0.0 22.5 45.0 67.5 90.0 5710 5188 4838 4623 4375 4067 3751 3381 3004 2644 2214 1727 5710 5018 4679 4477 4263 4014 3740 3491 3232 2998 2794 2598 5710 5083 4804 4648 4477 4305 4163 4057 3992 3995 3891 3618 5710 5109 4877 4762 4641 4566 4536 4574 4691 4740 4532 4274 5710 5109 4918 4826 4750 4710 4731 4848 5014 5024 4798 4579 Horiz 0-180 RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance Dimensional Data FNPS Ambient Suitability Chart 49/16" 23/16" 21/2" 75/8" NO. of lamps 2 Wattage/ Lamp Type 28W (T5), 4' 3 28W (T5), 4' 4 28W (T5), 4' 2 32W (T8), 4' 3 32W (T8), 4' 4 32W (T8), 8' 2 34W (T12), 4' 2 40W (T8), 4' 2 60W HO (T12), 4' 2 59W (T8), 8' 2 86W HO (T8),8' 40°C 25°C Ambient with Battery - Supply Wire Rating 90°C 90°C 35°C 25°C 30°C 25°C 40°C 40°C 30°C 25°C 40°C 40°C 30°C 25°C 35°C 25°C 25°C 40°C 25°C 35°C 25°C 40°C 40°C 30°C 25°C 40°C 40°C 30°C 25°C 35°C 25°C 25°C 40°C 25°C 35°C 25°C 90°C 90°C 90°C 90°C 90°C 90°C 90°C 90°C 90°C 90°C 90°C 90°C 90°C 90°C 90°C 90°C 90°C 90°C 90°C 90°C Ambient 1. 40°C applies to magnetic only. 49 15/16" NOTE: All dimensions are in inches; dimensions and specifications are subject to change without notice. Please consult factory or check sample for verification. Page 2/3 Rev. 02/12/13 Extreme Environment / fnps © 2013 Columbia Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Columbia Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Tech Support 864.678.1668 / Website www.columbialighting.com fnps Surface Mounting Details For LUN, FNPV, FNPS, LU PEBU Accessory 0.31" × 1.75" SLOT D 0.312" E 4.50" 3.12" 1.00" 0.31" × 1.69" SLOT PEBA Accessory 0.22" G 3.12" 90° Adjustments F D E F G 2' 25.75" (654 mm) 0" (0 mm) 25.75" (654 mm) 2.38" (60 mm) 4' 49.75" (1264 mm) 0.38 (10 mm) 49.75" (1264 mm) 2.75" (70 mm) 8' 97.75" (2483 mm) 0.38" (10 mm) 97.75" (2483 mm) 2.75 (70 mm) For FDPS, FDPH, FNPS, FNPV, FNPH PTBS Accessory1 D 0.44" × 0.89" SLOT E 0.75" 7.12" PTBA Accessory2 90° Adjustments 15° Increments F 0.31" G 2.38" 1.38" 1 2 D E F G 4' 45.65" (1118 mm) — 48.40" (1186 mm) — 8' 93.65" (2294 mm) 46.83" (1147 mm) 96.40" (2362 mm) 46.83 (1147 mm) PTBS has two mounting brackets; PTBS3 has three mounting brackets and only used with 8' fixtures. PTBA has two mounting brackets; PTBA3 has three mounting brackets and only used with 8' fixtures. NOTE: All dimensions are in inches; dimensions and specifications are subject to change without notice. Please consult factory or check sample for verification. Page 3/3 Rev. 02/12/13 Extreme Environment / fnps © 2013 Columbia Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Columbia Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Tech Support 864.678.1668 / Website www.columbialighting.com