fnph
Enclosed and Gasketed Fiberglass Industrial Hazardous Location / 2, 3, 4-Lamp T5, T8
Project Information
Features
Project Name
Type
Catalog No.
Date
Housing
One piece, high-impact, molded fiberglass
reinforced polyester housing supplied with (2) 1/2"
die cast aluminum hubs.
• For use in wet, outdoor, hazardous, hosedown, and corrosive
locations where high ambient environments can cause
abusive lighting conditions
• UL 844:Class I, Div. 2 Groups A, B, C, D; Class I, Zone 2 Groups
IIC, IIB, IIA
• IP65 listed for dust-tight, hosedown, and outdoor applications
• Accessible drop down ballast tray
• Up to 40°C ambient listed
• Wet location certified for ceiling and wall mount
• T5 28W lamp capability. Up to four lamps per 4' unit
• Ballast backup capability
• Patented end bracket system for UL 844 stress requirements
• Fiberglass reinforced polyester housing listed as an electrical
enclosure for thru-branch wiring
• Lens choices of acrylic/polycarbonate in crepe, prismatic,
opal, and clear design. High DR content also available
• Conduit hubs available in die-cast aluminum or 316 stainless
steel
• Nylon and stainless steel latches available with tamper proof
capability
• Mounting accessories in stainless or galvanized steel
Shielding
Standard lens is of 25% DR acrylic material. Higher
DR content acrylic and polycarbonate lenses are
available as an option.
Ballasts
Energy efficient, thermally protected, automatic
resetting, Class P, high power factor, sound rated
A, unless otherwise specified. CEE NEMA Premium
compliant.
Electrical
Standard class “P,” thermally protected, autoresetting HPF ballast, sound rated A. CEE NEMA
Premium compliant. All ballast leads extend a
minimum of 6" through access location.
Ordering Information
FNPH
4
Model
LEngth
FNPH Performer
Series,
Hazardous
Location
4 4'
–
Example FNPH4-232-DR-EU-2H
–
–
No. of Lamps In
Cross Section
2 Two
3 Three
4 Four
Lamp Type
28 4', T5: 28 Watt
32 4', T8: 32, 30, 28,
or 25 Watt
Certification
All luminaires are built to UL 1598 standards
and bear appropriate UL and cUL or CSA labels.
Wet location labeling is standard. IP65 rated for
Hazardous Locations. NFS listing available as
options. CSA certified to UL844.
–
Ballast1
Voltage
Entries
Options
E Electronic T8, Instant
Start (-20°F for HO
lamps)
EP Electronic T5 or T8,
Programmed Start
U 120V-277V
347 347V
220 220V
2H (2) ½"
Aluminum Hubs
2HS (2) 1/2" Stainless
Steel Hubs
2H3S (2) 3/4" Stainless
Steel Hubs
2HMS (2) 20 mm
Stainless Steel
Hubs2
GLR Fast Blow Fuse3
TP Tamper Resistant Latches
SSLTP Stainless Steel Tamper
Resistant Latches
BHD65U Hazardous and Damp
Rated Emergency
Battery Pack (T8 Only)
Lens
Blank
DR
CA
OA
PP
Acrylic Crepe, 25% DR
Acrylic Crepe, 100% DR
Clear Acrylic, 25% DR
Opal Acrylic, 25% DR
Clear Prismatic Polycarbonate
Accessories
(Order Separately)
Ballasts may not be available in all combinations of lamp/voltage/starting temp/THD shown above.
20 MM entries not CSA or ABS certified.
3
Fusing not available with CSA certification.
4
Recommend use of PTBS & PTBA accessories with stainless steel hubs.
1
2
Page 1/3 Rev. 11/24/13
© 2013 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice.
701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com
PTBS Top Bracket Surface Mount,
2 Per Kit, 304 Stainless4
PTBA Top Bracket Wall/Angle Kit,
2 Per Kit, 304 Stainless Steel4
TPSD Tamper Resistant Screwdriver
Extreme Environment / fnph
fnph
Enclosed and Gasketed Fiberglass Industrial Hazardous Location / 2, 3, 4-Lamp T5, T8
Photometric Data
Luminaire Data
0.0 22.5 45.0 67.5 90.0
0
30
40
45
50
55
60
65
70
75
80
85
56
Surface
0º = 90 90º = 90
5710
5191
4842
4627
4380
4072
3757
3387
3011
2652
2223
1739
5710
5028
4692
4491
4278
4031
3757
3510
3253
3022
2821
2631
5710
5098
4822
4668
4499
4330
4190
4087
4026
4035
3936
3669
5710
5126
4899
4786
4668
4595
4568
4612
4735
4791
4588
4337
5710
5126
4940
4850
4777
4741
4766
4889
5061
5078
4858
4647
0º = 1.21 90º = 1.42
Zonal Lumen Summary
Length: 4.08
Width: 0.56
Height: 0.22
Zone
0-30
0-40
0-60
0-90
0-180
17.1
28.5
52.4
77.1
85.7
RC
RW
1
2
3
4
5
6
7
8
9
10
70
89
80
72
66
60
56
52
48
45
42
80
50 30
84 79
72 65
62 55
55 47
49 41
44 36
39 32
36 28
33 26
30 23
10
75
60
49
41
35
30
26
23
21
19
70
86
77
69
63
58
53
50
46
43
40
70
50 30
81 77
69 63
60 53
53 46
47 40
42 35
38 31
35 28
32 25
29 23
10
73
58
48
40
34
29
26
23
20
18
50
76
65
57
50
44
40
36
33
30
28
50
30
72
60
51
43
38
33
30
27
24
22
Indoor Candela Plot
10
69
55
46
38
33
28
25
22
20
18
0
0
60
48
39
33
28
25
22
19
17
15
RCR = Room Cavity Ratio
RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
Energy Data
Lumens % Lamp % Fixt.
976
1625
2989
4394
4883
RCR
Ballast
Ballast Factor
Lamp
Lumens per
Lamp
Watts
Mounting
Shielding
Angle
Spacing
Criterion
Luminous
Opening in
Feet
AVG. Luminance (Candela/Sq. M.) Coefficients of Utilization (%)
FNPH-232-EU
FNPH Hazardous
Location
8" × 4' 2-Lamp with
acrylic crepe lens
E2-32IS-120SC
0.88
F32T8/TL735/ALTO
2850
Average Luminance Angle
Luminaire
Test 13914 Test Date 4/22/05
20.0
33.3
61.2
90.0
100.0
Total Luminaire Efficiency
85.7%
Luminaire Efficacy Rating (LER)
IESNA RP-1-2004 Compliance
Comparative Yearly Lighting
Energy Cost per 1000 Lumens
77
Noncompliant
$3.12 based on 3000 hrs.
and $0.08 per KWH
Test 13915 Test Date 4/22/05
Ballast
Ballast Factor
Lamp
Lumens per
Lamp
Watts
Mounting
Shielding
Angle
Spacing
Criterion
Luminous
Opening in
Feet
FNPH4-332-EU
FNPH Hazardous
Location
8" × 48" 3-lamp nonmetallic housing with
clear acrylic crepe
lens
RCN-3S32-SC
0.88
F32T8/TL735/ALTO
2850
88
Recessed
0º = 90 90º = 0
0º = 1.22 90º = 1.38
Length: 4.08
Width: 0.56
Height: 0.22
0.0 22.5 45.0 67.5 90.0
0
30
40
45
50
55
60
65
70
75
80
85
8056
7386
6896
6612
6232
5811
5326
4796
4247
3682
3075
2341
8056
7120
6635
6329
5989
5596
5164
4719
4301
3928
3545
3091
8056
7117
6713
6415
6107
5801
5548
5343
5191
4970
4568
4068
8056
7081
6695
6457
6252
6108
6006
5933
5794
5532
5066
4628
8056
7064
6716
6524
6370
6303
6224
6171
6055
5787
5320
4932
Zonal Lumen Summary
Zone
0-30
0-40
0-60
0-90
0-180
Lumens % Lamp % Fixt.
1371
2277
4139
5862
6409
16.0
26.6
48.4
68.6
75.0
21.4
35.5
64.6
91.5
100.0
RCR
Luminaire
AVG. Luminance (Candela/Sq. M.) Coefficients of Utilization (%)
Average Luminance Angle
Luminaire Data
RC
RW
1
2
3
4
5
6
7
8
9
10
70
78
71
64
59
54
49
46
43
40
37
80
50 30
74 70
64 58
56 49
49 42
44 37
39 32
35 29
32 26
29 23
27 21
10
67
53
44
37
31
27
24
21
19
17
70
76
68
62
56
52
48
44
41
38
36
70
50 30
72 68
62 57
54 48
48 41
42 36
38 31
34 28
31 25
29 23
26 21
10
65
52
43
36
31
27
23
21
19
17
50
67
58
51
45
40
36
33
30
27
25
50
30
65
54
46
39
34
30
27
24
22
20
Indoor Candela Plot
10
62
50
41
35
30
26
23
20
18
16
0
0
54
44
36
31
26
23
20
18
16
14
RCR = Room Cavity Ratio
RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
Energy Data
Total Luminaire Efficiency
75.0%
Luminaire Efficacy Rating (LER)
IESNA RP-1-2004 Compliance
Comparative Yearly Lighting
Energy Cost per 1000 Lumens
0
Noncompliant
$3.75 based on 3000 hrs.
and $0.08 per KWH
Product Availability
Dimensional Data
Size
4'
49/16"
23/16"
No. of lamps in
cross section
No. of lamps in
fixture
Lamp type
Ambient
Class I
DIV 2
Class II
ZONE 2
Length
2
2
2
2
2
3
3
4
2
2
2
2
2
3
3
4
34
34
32
44
28
28
32
28
25°C
35°C
40°C
25°C, 40°C
25°C, 40°C
25°C, 40°C
25°C, 40°C
25°C, 40°C
T4A
T4
T5
T5
T5
T4A
T5
T4A
T4
T4
T5
T5
T5
T4
T5
T4
4913/16"
4913/16"
4913/16"
4913/16"
4913/16"
4913/16"
4913/16"
4913/16"
27/16"
75/8"
49 15/16"
NOTE: All dimensions are in inches; dimensions and specifications are subject to change without notice. Please consult factory or check sample for verification.
Page 2/3 Rev. 11/24/13
© 2013 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice.
701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com
Extreme Environment / fnph
fnph
Surface Mounting Details
For LUN, FNPV, FNPS, LU
PEBU Accessory
0.31" × 1.75" SLOT
D
0.312"
E
4.50"
3.12"
1.00"
0.31" × 1.69" SLOT
PEBA Accessory
0.22"
G
3.12"
90° Adjustments
F
D
E
F
G
2'
25.75" (654 mm)
0" (0 mm)
25.75" (654 mm)
2.38" (60 mm)
4'
49.75" (1264 mm)
0.38 (10 mm)
49.75" (1264 mm)
2.75" (70 mm)
8'
97.75" (2483 mm)
0.38" (10 mm)
97.75" (2483 mm)
2.75 (70 mm)
For FDPS, FDPH, FNPS, FNPV, FNPH
PTBS Accessory1
D
0.44" × 0.89" SLOT
E
0.75"
7.12"
PTBA Accessory2
90° Adjustments
15° Increments
F
0.31"
G
2.38"
1.38"
1
2
D
E
F
G
4'
45.65" (1118 mm)
—
48.40" (1186 mm)
—
8'
93.65" (2294 mm)
46.83" (1147 mm)
96.40" (2362 mm)
46.83 (1147 mm)
PTBS has two mounting brackets; PTBS3 has three mounting brackets and only used with 8' fixtures.
PTBA has two mounting brackets; PTBA3 has three mounting brackets and only used with 8' fixtures.
NOTE: All dimensions are in inches; dimensions and specifications are subject to change without notice. Please consult factory or check sample for verification.
Page 3/3 Rev. 11/24/13
© 2013 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice.
701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com