fnph Enclosed and Gasketed Fiberglass Industrial Hazardous Location / 2, 3, 4-Lamp T5, T8 Project Information Features Project Name Type Catalog No. Date Housing One piece, high-impact, molded fiberglass reinforced polyester housing supplied with (2) 1/2" die cast aluminum hubs. • For use in wet, outdoor, hazardous, hosedown, and corrosive locations where high ambient environments can cause abusive lighting conditions • UL 844:Class I, Div. 2 Groups A, B, C, D; Class I, Zone 2 Groups IIC, IIB, IIA • IP65 listed for dust-tight, hosedown, and outdoor applications • Accessible drop down ballast tray • Up to 40°C ambient listed • Wet location certified for ceiling and wall mount • T5 28W lamp capability. Up to four lamps per 4' unit • Ballast backup capability • Patented end bracket system for UL 844 stress requirements • Fiberglass reinforced polyester housing listed as an electrical enclosure for thru-branch wiring • Lens choices of acrylic/polycarbonate in crepe, prismatic, opal, and clear design. High DR content also available • Conduit hubs available in die-cast aluminum or 316 stainless steel • Nylon and stainless steel latches available with tamper proof capability • Mounting accessories in stainless or galvanized steel Shielding Standard lens is of 25% DR acrylic material. Higher DR content acrylic and polycarbonate lenses are available as an option. Ballasts Energy efficient, thermally protected, automatic resetting, Class P, high power factor, sound rated A, unless otherwise specified. CEE NEMA Premium compliant. Electrical Standard class “P,” thermally protected, autoresetting HPF ballast, sound rated A. CEE NEMA Premium compliant. All ballast leads extend a minimum of 6" through access location. Ordering Information FNPH 4 Model LEngth FNPH Performer Series, Hazardous Location 4 4' – Example FNPH4-232-DR-EU-2H – – No. of Lamps In Cross Section 2 Two 3 Three 4 Four Lamp Type 28 4', T5: 28 Watt 32 4', T8: 32, 30, 28, or 25 Watt Certification All luminaires are built to UL 1598 standards and bear appropriate UL and cUL or CSA labels. Wet location labeling is standard. IP65 rated for Hazardous Locations. NFS listing available as options. CSA certified to UL844. – Ballast1 Voltage Entries Options E Electronic T8, Instant Start (-20°F for HO lamps) EP Electronic T5 or T8, Programmed Start U 120V-277V 347 347V 220 220V 2H (2) ½" Aluminum Hubs 2HS (2) 1/2" Stainless Steel Hubs 2H3S (2) 3/4" Stainless Steel Hubs 2HMS (2) 20 mm Stainless Steel Hubs2 GLR Fast Blow Fuse3 TP Tamper Resistant Latches SSLTP Stainless Steel Tamper Resistant Latches BHD65U Hazardous and Damp Rated Emergency Battery Pack (T8 Only) Lens Blank DR CA OA PP Acrylic Crepe, 25% DR Acrylic Crepe, 100% DR Clear Acrylic, 25% DR Opal Acrylic, 25% DR Clear Prismatic Polycarbonate Accessories (Order Separately) Ballasts may not be available in all combinations of lamp/voltage/starting temp/THD shown above. 20 MM entries not CSA or ABS certified. 3 Fusing not available with CSA certification. 4 Recommend use of PTBS & PTBA accessories with stainless steel hubs. 1 2 Page 1/3 Rev. 11/24/13 © 2013 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com PTBS Top Bracket Surface Mount, 2 Per Kit, 304 Stainless4 PTBA Top Bracket Wall/Angle Kit, 2 Per Kit, 304 Stainless Steel4 TPSD Tamper Resistant Screwdriver Extreme Environment / fnph fnph Enclosed and Gasketed Fiberglass Industrial Hazardous Location / 2, 3, 4-Lamp T5, T8 Photometric Data Luminaire Data 0.0 22.5 45.0 67.5 90.0 0 30 40 45 50 55 60 65 70 75 80 85 56 Surface 0º = 90 90º = 90 5710 5191 4842 4627 4380 4072 3757 3387 3011 2652 2223 1739 5710 5028 4692 4491 4278 4031 3757 3510 3253 3022 2821 2631 5710 5098 4822 4668 4499 4330 4190 4087 4026 4035 3936 3669 5710 5126 4899 4786 4668 4595 4568 4612 4735 4791 4588 4337 5710 5126 4940 4850 4777 4741 4766 4889 5061 5078 4858 4647 0º = 1.21 90º = 1.42 Zonal Lumen Summary Length: 4.08 Width: 0.56 Height: 0.22 Zone 0-30 0-40 0-60 0-90 0-180 17.1 28.5 52.4 77.1 85.7 RC RW 1 2 3 4 5 6 7 8 9 10 70 89 80 72 66 60 56 52 48 45 42 80 50 30 84 79 72 65 62 55 55 47 49 41 44 36 39 32 36 28 33 26 30 23 10 75 60 49 41 35 30 26 23 21 19 70 86 77 69 63 58 53 50 46 43 40 70 50 30 81 77 69 63 60 53 53 46 47 40 42 35 38 31 35 28 32 25 29 23 10 73 58 48 40 34 29 26 23 20 18 50 76 65 57 50 44 40 36 33 30 28 50 30 72 60 51 43 38 33 30 27 24 22 Indoor Candela Plot 10 69 55 46 38 33 28 25 22 20 18 0 0 60 48 39 33 28 25 22 19 17 15 RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance Energy Data Lumens % Lamp % Fixt. 976 1625 2989 4394 4883 RCR Ballast Ballast Factor Lamp Lumens per Lamp Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in Feet AVG. Luminance (Candela/Sq. M.) Coefficients of Utilization (%) FNPH-232-EU FNPH Hazardous Location 8" × 4' 2-Lamp with acrylic crepe lens E2-32IS-120SC 0.88 F32T8/TL735/ALTO 2850 Average Luminance Angle Luminaire Test 13914 Test Date 4/22/05 20.0 33.3 61.2 90.0 100.0 Total Luminaire Efficiency 85.7% Luminaire Efficacy Rating (LER) IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens 77 Noncompliant $3.12 based on 3000 hrs. and $0.08 per KWH Test 13915 Test Date 4/22/05 Ballast Ballast Factor Lamp Lumens per Lamp Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in Feet FNPH4-332-EU FNPH Hazardous Location 8" × 48" 3-lamp nonmetallic housing with clear acrylic crepe lens RCN-3S32-SC 0.88 F32T8/TL735/ALTO 2850 88 Recessed 0º = 90 90º = 0 0º = 1.22 90º = 1.38 Length: 4.08 Width: 0.56 Height: 0.22 0.0 22.5 45.0 67.5 90.0 0 30 40 45 50 55 60 65 70 75 80 85 8056 7386 6896 6612 6232 5811 5326 4796 4247 3682 3075 2341 8056 7120 6635 6329 5989 5596 5164 4719 4301 3928 3545 3091 8056 7117 6713 6415 6107 5801 5548 5343 5191 4970 4568 4068 8056 7081 6695 6457 6252 6108 6006 5933 5794 5532 5066 4628 8056 7064 6716 6524 6370 6303 6224 6171 6055 5787 5320 4932 Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 0-180 Lumens % Lamp % Fixt. 1371 2277 4139 5862 6409 16.0 26.6 48.4 68.6 75.0 21.4 35.5 64.6 91.5 100.0 RCR Luminaire AVG. Luminance (Candela/Sq. M.) Coefficients of Utilization (%) Average Luminance Angle Luminaire Data RC RW 1 2 3 4 5 6 7 8 9 10 70 78 71 64 59 54 49 46 43 40 37 80 50 30 74 70 64 58 56 49 49 42 44 37 39 32 35 29 32 26 29 23 27 21 10 67 53 44 37 31 27 24 21 19 17 70 76 68 62 56 52 48 44 41 38 36 70 50 30 72 68 62 57 54 48 48 41 42 36 38 31 34 28 31 25 29 23 26 21 10 65 52 43 36 31 27 23 21 19 17 50 67 58 51 45 40 36 33 30 27 25 50 30 65 54 46 39 34 30 27 24 22 20 Indoor Candela Plot 10 62 50 41 35 30 26 23 20 18 16 0 0 54 44 36 31 26 23 20 18 16 14 RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance Energy Data Total Luminaire Efficiency 75.0% Luminaire Efficacy Rating (LER) IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens 0 Noncompliant $3.75 based on 3000 hrs. and $0.08 per KWH Product Availability Dimensional Data Size 4' 49/16" 23/16" No. of lamps in cross section No. of lamps in fixture Lamp type Ambient Class I DIV 2 Class II ZONE 2 Length 2 2 2 2 2 3 3 4 2 2 2 2 2 3 3 4 34 34 32 44 28 28 32 28 25°C 35°C 40°C 25°C, 40°C 25°C, 40°C 25°C, 40°C 25°C, 40°C 25°C, 40°C T4A T4 T5 T5 T5 T4A T5 T4A T4 T4 T5 T5 T5 T4 T5 T4 4913/16" 4913/16" 4913/16" 4913/16" 4913/16" 4913/16" 4913/16" 4913/16" 27/16" 75/8" 49 15/16" NOTE: All dimensions are in inches; dimensions and specifications are subject to change without notice. Please consult factory or check sample for verification. Page 2/3 Rev. 11/24/13 © 2013 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com Extreme Environment / fnph fnph Surface Mounting Details For LUN, FNPV, FNPS, LU PEBU Accessory 0.31" × 1.75" SLOT D 0.312" E 4.50" 3.12" 1.00" 0.31" × 1.69" SLOT PEBA Accessory 0.22" G 3.12" 90° Adjustments F D E F G 2' 25.75" (654 mm) 0" (0 mm) 25.75" (654 mm) 2.38" (60 mm) 4' 49.75" (1264 mm) 0.38 (10 mm) 49.75" (1264 mm) 2.75" (70 mm) 8' 97.75" (2483 mm) 0.38" (10 mm) 97.75" (2483 mm) 2.75 (70 mm) For FDPS, FDPH, FNPS, FNPV, FNPH PTBS Accessory1 D 0.44" × 0.89" SLOT E 0.75" 7.12" PTBA Accessory2 90° Adjustments 15° Increments F 0.31" G 2.38" 1.38" 1 2 D E F G 4' 45.65" (1118 mm) — 48.40" (1186 mm) — 8' 93.65" (2294 mm) 46.83" (1147 mm) 96.40" (2362 mm) 46.83 (1147 mm) PTBS has two mounting brackets; PTBS3 has three mounting brackets and only used with 8' fixtures. PTBA has two mounting brackets; PTBA3 has three mounting brackets and only used with 8' fixtures. NOTE: All dimensions are in inches; dimensions and specifications are subject to change without notice. Please consult factory or check sample for verification. Page 3/3 Rev. 11/24/13 © 2013 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com Extreme Environment / fnph