1300 Industrial Road, Unit #19 San Carlos, CA 94070 FREE CALL 1-866-695-5862 US & Canada info@lumascape.com Ingrade LS363LED IP68 OPTIONAL PTIONAL TIONAL PTIONAL IK10 OPTIONAL The LS363LED is a robust, medium wattage ingrade luminaire, featuring high efficacy Lumileds™ LEDs. As an inherently protected luminaire it can be used in interior spaces and immediately adjacent to combustible materials (such as wood decking, etc). In addition, internal rotation and tilt adjustability ensures the most efficient light delivery can be set according to the site conditions. Specifications Lamp Source 16 LED □ White (4 300 K typical) ■ Warm white (3 000 K typical) ■ Warm white (2 700 K typical) ■ Blue (470 nm) Other colors by request Approved Use Suitable for wet locations Suitable for use in poured concrete Inherently protected Lumen Maintenance (L70) Limited by TM-21 x6 rule IP Rating IP68 Construction 316 marine grade stainless steel Installation Types Pre-Installation Blockout Concrete pour, drive-over & general use applications LS363LED with round flush cover and GripGlass™ >60,000 hrs 360° 15° 15° Direct Burial Landscapes, planters & special applications (consult factory) Drive-over With OptiClear™ lens and pre-installation blockout LS644-K Static Load Rating 6 600 lb (3 000 kg) with OptiClear™ lens and preinstallation blockout LS644-K (Load applied to center of glass across a 2" diameter area) Impact Rating IK10 with OptiClear™ lens Standard Inclusions Teflon coated cover screws MicroAntiLeach™ wire entry Accessories LS644-K pre-installation blockout LS645 brass grill (For use with direct burial, recessed cover type only) Ambient Operating Temperature -22 °F to 122 °F (-30 °C to +50 °C) Surface Temperature ≤113 °F (45 °C) Photometrics Refer to www.lumascape.com Any luminaire can become hot - take care with appropriate use and placement www.lumascape.com 29 Aug 2016 LS363LED Pre-installation Ingrade Why Use LS644-K-87-09 Pre-Installation Blockout? Why Use LS644-K-84 Pre-Installation Blockout? The LS644-K-87-09 acts as a blockout, and is intended for installation before the luminaire, however it has other special functions. To simplify the installation, every LS644-K-87-09 is supplied complete with a 4-way, ¾" PVC junction box, inside which the installer can make all necessary connections, and allows the completion of all wiring even before the luminaire arrives on site. This method also ensures the luminaire itself is not damaged during concreting or other site works. Note: The junction box remains serviceable after installation. To complete the installation, Lumascape provides an IP68 connector, enabling a tool-free final connection from the luminaire to the branch circuit. In addition, this connector is readily detachable, allowing for off-site maintenance. The LS644-K-84 pre-installation kit (order separately) is ideal for use in applications where maximum flexibility for the type and location of branch circuit connections are required or where exact site conditions may be unknown. For use with the LS644-K-84, Lumascape provides the LS363LED complete with 6.5' of factory-installed hookup wire or an SOOW cord (both options include a MicroAntiLeach™ seal). This provides the installer with greater flexibility to determine the type and location of the branch circuit connection. This option is also 100% hardwired, and does not feature the IP68 detachable couplings for off-site maintenance. All aspects of the luminaire itself are still field serviceable. Lens Options (1 Ø5. 36 4” m m ) Connection Type '87' for LS644-K-87-09 Pre-Installation Blockout 14.6” (372 mm) Ø8.3” (210 mm) OptiClear™ Glass Glass of very high optical purity and load strength. Suitable for walk-over and drive-over applications. IP68 Connector & Junction Box The luminaire is fitted with an IP68 connector, which attaches directly to the cord supplied with LS644-K-87-09, without the use of any tools. The cord is 1.8' (0.56 m) in length, and is factory assembled with a 4 way, ¾" junction box - Remains field serviceable after installation. GripGlass™ OptiClear™ glass with slip reduction glazing process. Suitable for walk-over and drive-over applications. Connection Type '84' for LS644-K-84 Pre-Installation Blockout Cover Options for Pre-Installation Blockout Connection Type '82' for LS644-K-84 Pre-Installation Blockout Flush covers for pre-installation use special seals and support bushes to ensure static loads up to 6 600 lb (3 000 kg) are properly supported. In order to achieve this driveover rating, OptiClear™ or GripGlass™ must be used. 6.5' SOOW Cord ½" NPT Adapter For connection to the branch circuit via junction box (by others) or other approved method. The luminaire is factory-fitted with 6.5' hookup wire. Ensure terminations can be made within this length. Pre-Installation Blockout Round Flush Cover c/w 6.5' SOOW Cord (16/3) For other length options, consult factory. ■ SS316: Polished www.lumascape.com ■ SS316: Brushed 29 Aug 2016 LS363LED Pre-installation Product Lamp Lens Ingrade Cover Connection Type Optical System LS363LED LAMP Housing Depth Wire Entry Location 23 Q Input Voltage OPTICAL SYSTEM Description Wattage Color LED 16 W Code Description Beam Code 1 W4 Adjustable 1 H6 Adjustable Warm white 1 D7 Adjustable Blue NR ME WD LH (1) LV (1) 1 B4 White (4 300 K typ.) Warm white (3 000 K typ.) (2 700 K typ.) (470 nm) Adjustable 0 Adjustable Refer to beam orientation diagram below. HOUSING DEPTH LENS Description OptiClear™ Description Code Very high optical purity and load strength GripGlass™ OptiClear™ with slip reduction glazing process (1) Wide Code 23 14.6" (372 mm) A (1) WIRE ENTRY LOCATION G (1) Description Suitable for drive-over. Code Q Bottom COVER Description Material Finish Round Flush Cover Stainless steel Polished Brushed INPUT VOLTAGE Code Description M N Code 120-277 V, 50/60 Hz 120V, 50/60 Hz Forward Phase Dimmable Driver 09 25 CONNECTION TYPE Description Code IP68 Connector & Junction Box 87 (1) 6.5' SOOW Cord 84 (2) ½" NPT Adapter 82 (2) (1) (2) LS644-K-87-09 required - order separately. LS644-K-84 required - order separately. LS363LED Accessories Stacking and order of accessories LS667 Solite Lens LED Beam Orientations Beam Orientation for the "LV" optical system www.lumascape.com Beam Orientation for the "LH" optical system 29 Aug 2016 LS363LED Direct Burial Ingrade Why Use Direct Burial? Direct burial installation is ideal for landscaping areas or for special applications where depth is restricted. This type of installation also allows for maximum heat dissipation. The 316 grade Stainless Steel construction of the luminaire performs flawlessly in alkaline and acidic soil types, and is also rated for use in concrete pour applications. Note: This installation type has no option for a pre-installation blockout. Lumascape provides the LS363LED complete with 6.5' of factory installed hookup wire and ½" NPT adapter, supplied complete with MicroAntiLeach™ seal. This provides the installer with greater flexibility to determine the nature of the branch circuit connection. This connection is also 100% hardwired. All aspects of the luminaire itself remains field serviceable. Consult factory for application advice prior to using this configuration. Connection type '82' for 'Direct Burial' housing Lens Options OptiClear™ Glass Glass of very high optical purity and load strength. Suitable for walk-over and driveover applications. ½" NPT Adapter The luminaire is factory-fitted with 6.5' hookup wire. Ensure terminations can be made within this length. For other length options, consult factory. GripGlass™ OptiClear™ glass with slip reduction glazing process. Suitable for walk-over and drive-over applications. Cover Options for Direct Burial Use recessed cover for installation in soil, grass, pavers and other uneven surfaces where no cover overhang is desired. Use flush covers for installation in fine finished surfaces such as granite and marble. They can also be used in some suspended applications. The flush cover will conceal gaps between the luminaire and the surrounding surface. Recessed Cover Round Flush Cover Square Flush Cover ■ SS316: Polished ■ SS316: Brushed ■ SS316: Polished ■ SS316: Brushed ■ SS316: Brushed www.lumascape.com Ø 5.6” (142 mm) 0.1” (3 mm) 0.1” (3 mm) Ø7.4” (187 mm) Housing OD 8.7” (221 mm) 8.7” (221 mm) 8.7” (221 mm) Ø5.6” (142 mm) 0.98” (25 mm) Ø (1 5. 36 4” m m ) Ø 36 5.4” m m ) (1 (1 Ø 5 36 .4” m m ) Ø7.4” (187 mm) Housing OD Ø7.4” (187 mm) Housing OD 0.98” (25 mm) Ø8.0” (204 mm) Ø8.0” (204 mm) Cover OD 0.98” (25 mm) Ø 5.6” (142 mm) 29 Aug 2016 LS363LED Direct Burial Product Lamp Lens Ingrade Cover Connection Type LS363LED Optical System 82 LAMP Housing Depth Wire Entry Location Input Voltage 21 OPTICAL SYSTEM Description Wattage Color LED 16 W Code Description Beam Code 16W4 Adjustable 16H6 Adjustable Warm white 16D7 Adjustable Blue NR ME WD LH (1) LV (1) 16B4 White (4 300 K typ.) Warm white (3 000 K typ.) (2 700 K typ.) (470 nm) Adjustable 0 Adjustable (1) Refer LENS Description Wide HOUSING DEPTH Code OptiClear™ Very high optical purity and load strength A GripGlass™ OptiClear™ with slip reduction glazing process G to beam orientation diagram below. Description Code 21 8.7" (221 mm) WIRE ENTRY LOCATION Description Code N Q Side COVER Bottom Description Material Finish Recessed Cover Stainless steel Polished Round Flush Stainless Cover steel Polished Square Flush Stainless Cover steel Brushed Brushed Brushed Code B H INPUT VOLTAGE D I 120-277 V, 50/60 Hz Description Code 120V, 50/60 Hz Forward Phase Dimmable Driver 09 25 V LS363LED Accessories CONNECTION TYPE Description Stacking and order of accessories Code 82 ½" NPT Adapter LS645 Brass grill External accessory Use with recessed covers only Not suitable for use in traffic areas LS667 Solite Lens LED Beam Orientations Beam Orientation for the "LV" optical system www.lumascape.com Beam Orientation for the "LH" optical system 29 Aug 2016