corelite - Villa Lighting

advertisement
CORELITE
DESCRIPTION
A unique alternative to the traditional fluorescent "wrap-around" fixture, the
Class Rs Surface features a minimalistic profile with maximum architectural
appeal, ideal for low ceiling applications. The Class Rs Surface utilizes the
same efficient center optics found in the Class R recessed series for
controlled brightness while offering a linear suspended or surface-mounted
solution to complete any Class R project with a cohesive appearance.
Type
Catalog #
Project
Date
Comments
Prepared by
SPECIFICATION FEATURES
A ... Construction
Formed 20 gauge steel gear tray
mounts to shielding via 2 factory
supplied clips.
B ... End Caps
Injection-molded plastic end caps.
C ... Reflectors
High reflectance white powder coat
painted reflector system.
D ... Shielding
Linear prismatic fully frosted
acrylic lens. Lens secured to
housing via injection molded
inserts for easy lamp access.
E ... Electrical
T5/T5HO fixtures are pre-wired
with quick wire connectors and use
UL listed Class P, T5/T5HO
program rapid start universal
voltage electronic ballasts, power
factor of 97% with less than 10%
THD. Fixtures and electrical
components certified to UL and
CUL standards.
Mounting
Class Rs is for individual surface
mounting only. Luminaire requires
2 factory supplied formed steel
painted mounting clips to be
installed to structure with
hardware by others (see
installation instructions). Fixture
then temporarily hangs onto clips
to allow hands-free wiring, then
fixture swings into place and is
ultimately secured by factory
supplied hardware.
CLASS Rs
Lensed
2T5
2T5HO
A
C
E
B
D
Surface
Direct
END CAP
Light Distribution
Indirect - 0.0%
Direct - 100%
1-3/4"
[44mm]
5/8"
[16.85mm]
6" [152mm]
M O D U L E S A N D D I M E N S I O N S*
48" [1219mm]
*Dimensions do not include end caps.
ORDERING INFORMATION
Sample Number: RB-WL-2N5-1C-UNV-SU
Series
RB=Class Rs
Surface
Reflector
W=White
Shielding
L=Linear Prismatic Lens
Number of Lamps
2=2 Lamps
Lamp Type
N5=T5 Normal Output
Wiring
B=Battery Pack
Voltage
120=120V
T5=T5 High Output
C=Standard Circuit
D=Dimming / Step
Dimming
277=277V
347=347V
Number of Circuits
1=1 Circuit
2=2 Circuits
E=Emergency
T=Nightlight
Suspension
SU-JB=Surface
Mount
Options
SD=Step Dimming1
UNV=Universal
(120V-277V)
Y=Daylight
Notes: 1
Must specify "D" for Wiring
Specifications and Dimensions subject to change without notice.
Consult your representative for additional options and finishes.
ADE090329
05/12/2009 1:30:00 PM
Download