absent - A Light

advertisement
ABSENT
ABSENT
SIMPLIFIED
INSTALLATION
AND MAINTENANCE
Installation methodology
designed specifically for
small proximity conditions:
stress-free installation of
the outer housing from in
front or below. Tool-less
snap-in internal LED trays
streamline installation and
maintenance.
ANATOMY
POWERFUL
PERFORMANCE
High performance Nichia 80+
CRI LEDs provide an optimal
light source for tailored lighting
design.
3.56”
DEEP DISTRIBUTION
Wide indirect light distribution
and a high transmissive
textured opal lay-in lens
delivers understated high
performance illumination
deep into the room.
2.10”
2.75”
GYPSUM BOARD
8.00”
CORE CAPACITY
Integral 0-10V dimming driver down to
10% or 1% standard. Additional options
include Lutron, DMX, and DALI control
protocols. Integral IOTA slim 12W
emergency battery pack provides an
easy solution for egress compliance.
BLIND SCREW
MOUNTING
EDGELESS
PRECISION
A 60% recycled aluminum
extruded chiseled edge
housing forms a precise
architectural cove.
INTEGRATIONS
Integrations is a comprehensive product line comprised of exact length fixtures, continuous rows, and patterns comprised of 90° illuminated
corners.
INTERGRATIONS+
Integrations+ is a completely custom ordering process allowing unique modifications and non-90° transitions through collaboration with
Design Assist.
w w w. a lig h ts . c o m
ABSENT
MOUNTING
MOUNTING OPTIONS
STANDARD PATTERNS
2
2
1
1
(PL)
2
1
3
3
(PU)
4
|
(R) Direct wall mount
(PR)
EASE OF INSTALLATION
Remove Lens via tooless snap
Locate powerfeed and drill hole
through the back of the housing,
or use knockout on endcap.
drilling drywall screws (by others)
through the channel located in the
safe zone
2 3/8” from edge
drilling drywall screws (by others)
through the channel located in the
Attach drywall via 1.5” self drilling
drywall screws (by others)
2 3/8” from edge (safe zone)
Apply drywall mud
w w w. a lig h ts . c o m
Drilling outside of the safe zone,
or use of a longer screw, will
result in penetration of the visible
ABSENT
INTEGR ATIONS
Ordering Code
2.25”
ABS
H
R
Project Info
3.50”
Type
Series:
Emergency:
Lengths not available in Elements
Specify in inches to the nearest 1/8th
M___
e.g. M180.00
Pattern options:
Specify in inches to the nearest 1/8th
See Pattern Guide for details.
“L” Shape
e.g. PL103.125x 134.00
PL___X___
“U” Shape
PU___X___
Rectangle / Square
PR___X___
e.g. PU103.125 x 134.00 x 103.125
e.g. PR103.125 x 134.00
Quantity
ABS
Length or Pattern Type:
Exact Length
Date
Emergency - circuited
Emergency - battery
ILB-SL-CP12 (1200lm for 90min)
Specify desired quantity of batteries
Not available on fixtures < 4’ length
EC
E___
Options:
Multi-circuit
M
New York City code
90+ CRI
N
CRI
Submit multi-circuiting requirements
Output:
LED standard output (5 W/ft)
LED high output (10 W/ft)
LED custom output
LED CCT:
3000K
3500K
4000K
LS
LH
C___
30
35
40
Voltage:
Universal 120V - 277V
347V
Indirect Optics:
HTD
TM
Lens
Mounting:
Wall
U
3
H
H
R
R
Finish:
Primed, gray
Other Specify RAL#
P
O__
Dimming:
Standard 0-10 dimming
Dimming to 1%, see technical section
Lutron Eco H series (LDE1)
Other dimming specify model/series
D
D1
D3__
Damp Location Rated
w w w. a lig h ts . c o m
ABSENT
TECHNICAL DATA
MOUNTING
LINEAR DIMENSIONS
Integrations - Exact lengths to the nearest 1/8th of an inch available as
individual fixtures or joined to create continuous row lengths, minimum
fixture length is 12 inches. Patterns comprised of 90 degree precisely
welded fully illuminated corners provide a multitude of geometric options
and architectural transitions.
Integrations + - Contact Design Assist for modifications to product not
detailed within Elements or Integrations specification sheets.
OPTICS
HTD™ lens is a high performance polycarbonate opal lens. An
optimized surface texture plus advanced diffusing additives produce an
impressive 93% transmission while eliminating LED hotspots.
LED LIGHT SOURCE
Custom manufactured linear board array uses high performance
Nichia® LED in combination with a performance driven heat sink
technology. Tested in accordance with LM79 and LM-80;
L70>60,0000hr; operated at reduced output for high efficacy and lumen
maintenance. 3000K, 3500K, and 4000K with 80+ CRI standard; other
color temperatures and 90+ CRI available upon request, contact factory.
LED color variation maintained at a 3-step MacAdam ellipse (SDCM 3x).
LEDs are available in Low, Standard, and High outputs. Refer to
photometry for delivered lumens. Custom output available in the range
of 300 to 1500 lumens/ft, contact factory.
Fixture housing attaches to wall via drywall screws (by others) through
pre-drilled channel in back of fixture. Drywall attaches to bottom of
fixture housing via drywall screws (by others) and is mudded over and
painted by installing contractor to provide “edgeless” cove system
appearance. Lens and internal gear trays to be removed via tool-less
snaps prior to mounting the fixture housing.
STRUCTURE
Robust, high quality 60% recycled aluminum extruded housing. 0.020”
stainless steel spring tabs for snap-in 0.040” aluminum internal gear
tray. 2 lbs/ft approximate fixture weight.
FINISH
Factory applied gray primer protects the aluminum fixture housing,
ensures proper paint (field applied) adhesion, and increases durability.
Factory-standard electrostatically applied powder coat finish and
custom finish options also available.
WARRANTY
Limited defect-free manufactured equipment warranty provided under
normal use and proper storage for a period of one (1) year. LED
products (LED boards and drivers) will be covered for a period of five (5)
years. Please refer to full terms and conditions on our website.
LED DIMMING DRIVER
Factory tuned constant current electronic 0-10V control dimming driver
is standard. Specification grade dimming down to 10% standard.
Contact factory if 1% dimming is required. Driver life of 50,000 hrs with
ambient operating temperature range of -30°C to 50°C, maximum case
temperature of 75°C. Electrical specifications at maximum driver load:
PF >0.9, THD <20%, >85% Efficiency. Other available drivers include
Lutron Eco-system H-series (LDE1): Hi-lume™ 1% LED dimming driver
with Soft On, Fade to Black; and DMX and DALI protocol drivers. Other
Lutron and specialty drivers available, contact factory.
EMERGENCY
Factory installed integrated fixture LED emergency battery pack for both
normal and emergency operation. Unit contains long-life Ni-Cad
recyclable battery, 24 hour charger, converter circuit, test switch and
charge indicator. Emergency mode provides constant power to a
nominal 12W LED load for a period of 90 minutes, delivering 1200
lumens of unwavering illumination throughout the full 90 minute
emergency duration. Unless otherwise specified, the emergency
battery pack will illuminate one 2 foot end of the fixture in the direct
portion of the fixture.
Emergency circuiting provided as a separate circuit from normal power
circuit according to NEC requirements, specify circuit length and
location.
w w w. a lig h ts . c o m
Download