Water chiller
4
WSAT-XEE: cooling only
4
WSAN-XEE: heat pump
Air cooled
Outdoor installation
Capacity from 24,3 to 72,2 kW
On Line Monitoring Service available
A
Eurovent Energy
Efficiency Class
ELFO
82÷302
Liquid chillers and heat pumps of the ELFOEnergy WSAT-XEE and WSAN-XEE series are units designed for outdoor installation and best energy efficiency in relation to their reduced size.
The ELFOEnergy series has been the turning point in the evolution of chillers.
Every unit has been conceived and made by applying state-of the art technology, emphasising the qualities of EFFICIENCY , SELF-ADAPTATION and EASY
INSTALLATION that distinguish this product
Thanks to its constructional and electronic peculiarities, ELFOEnergy permits:
4 high energy efficiency, in particular during partial-load operation, thanks to the use of two compressors with different capacities that work on a single refrigerant circuit;
4 Eurovent energy efficiency classification class "A" in heating operation, also in full load condition;
4 adaptability of operating parameters to the load conditions of the connected system, thereby optimising consumption, efficiency and working life of the parts;
4 easy, quick installation thanks to the standard hydronic group and the factory test carried out prior to dispatch;
4 installation of hydronic group with non-standard working head pumps or with double pump .
AIR R-410A
Cooling only
(WSAT-XEE)
Heating-Cooling
(WSAN-XEE)
Air cooled Outdoor inst.
Refrig. R-410A
WSAT-XEE
(1)
S 82
(2)
400TN
(3)
1PUS
(4)
-
(1) LOW TEMPERATURE:
4 S
4 B
Standard
Low water temperature
This version allows unit operation within the water and glycol mixing temperature range between +4°C and -8°C inclusive.
4 DSPB Double set-point for water low temperature (Brine)
(2) SUPPLY VOLTAGE:
4
400TN 400/3/50+N
(3) HYDRONIC GROUP USER SIDE:
4
1PUS Standard pump
4
1PUR Single pump with reduced discharge head
4 1PUM Single pump with larger discharge head
4 2PUS Standard double pump
4
2PUR Double pump with reduced discharge head
4
2PUM Double pump with larger discharge head
4 Not required
(4) ENERGY RECOVERY:
4
-
4 D
Not required (Standard)
Partial recovery
Carried out using braze-welded plate-type exchangers suited for recovering the desuperheating heat up to a maximum of
25% of the total unit heat.
Herm. Scroll ELFOControl Ice protection system (WSAN-XEE only)
(5)
OHP
(6)
-
(7)
-
(8)
-
(9)
-
(10)
-
(5) OPERATION (WSAN-XEE only):
4 OHP Operation in heat pump
Cooling and heating unit (Standard)
4
OHO Operation in heating-only
Heating only unit
(6) CONDENSER COIL:
4
CCS Standard condenser coil
4
CCCA Condenser coil in copper/aluminium with acrylic coating
4 CCCA1 Condenser coil in copper/aluminium with Fin Guard (Silver) treatment
4
CCCC Condenser coil in copper/copper
(7) SOFT STARTER:
4 Not required (Standard)
4
SFSTR4N Device for inrush current reduction, for 400/3/50+N units
(8) FREE CONTACTS HEATING EXTERNAL SIGNAL:
4 -
4
CLS
Not required (Standard)
Free Contacts External Signal
(9) SHUNT CAPACITORS (POWER FACTOR > 0,9):
4 -
4
PFCP
Not required (Standard)
Shunt capacitors (power factor > 0,9)
(10) STORAGE TANK:
4 Not required (Standard)
4
ACC1 Teflon steel storage tank
4
4
4
4
4
4
4
Rubber antivibration mounts
Serial communication module (MODBUS)
Steel mesh filter on water side (when unit is in “without hydronic group” configuration)
High and low pressure gauges
Daily and weekly programming clock
Finned coil protection grilles
Phase monitor to check the presence and correct sequence of the power supply phases
4
Control keypad for remote installation that repeats all the functions already present on the onboard microprocessor control
4
Humidity probe for summer set point compensation according to the outside enthalpy and defrosting optimization in winter operation
Key to symbols:
Accessories supplied separately.
Sizes
Application with terminal units
Cooling capacity WSAT-XEE
Total input WSAT-XEE
EER - WSAT-XEE
ESEER - WSAT-XEE
Heating capacity
Total input
COP
Pump working head WSAT-XEE
Number of refrigerant circuits
Number and type of compressors
Sound pressure level
Power supply
(1)
(1)(2)
(1)
(3)
(2)(3)
(3)
(1)
(4)
Application with radiant panels (WSAN-XEE only)
(5)
Total input
EER
Heating capacity
Total input
COP
Pump working head
Number of refrigerant circuits
Number and type of compressors
Sound pressure level
Power supply
(2)(5)
(5)
(6)
(2)(6)
(6)
(5)
(4) kW kW
kPa
-
kW kW
-
dB(A)
V/Ph/Hz
kW
kPa kW kW
kW
dB(A)
V/Ph/Hz
60
60
Data referred to the following conditions:
(1) Internal exchanger water = 12/7°C; air entering external exchanger = 35°C
(2) Total input is obtained from the compressor input + fan input + auxiliary circuit input.
(3) Ambient temperature = 7°C (R.H. = 85%); internal exchanger water outlet temperature 45°C
31,5
9,95
3,16
29,2
7,07
4,13
92
82
24,3
8,90
2,73
4,32
28,8
9,00
3,20
132 leave free
B1
B
B2
A1
C
A
A2
122
33,7
12,5
2,71
4,18
37,5
11,7
3,20
120
60
43,8
14,4
3,0
38,0
9,1
4,2
73
60
102
28,2
10,4
2,72
4,48
32,9
10,3
3,20
126
60
36,7
11,86
3,09
33,6
7,97
4,21
80
60
162 182
40,0
14,2
2,81
4,20
45,6
45,9
16,7
2,74
4,34
53,0
14,1
3,23
104
16,5
3,21
88
1
2 SCROLL
61 62
400/3/50+N
52,6
16,8
3,1
46,9
60,2
18,9
3,2
54,1
11,2
4,2
43
13,3
4,1
17
1
2 SCROLL
61 62
400/3/50+N
302
72,2
26,6
2,71
4,06
83,7
25,6
3,27
131
64
97,2
30,5
3,2
85,4
21,1
4,1
83
64
262
64,1
23,4
2,74
4,19
72,4
22,2
3,27
139
64
83,1
26,6
3,1
74,0
18,2
4,1
102
64
222
54,4
20,1
2,71
4,47
61,9
19,0
3,26
148
62
72,3
22,7
3,2
63,3
15,6
4,1
111
62
(4) Sound levels refer to units with full load under nominal test conditions. The sound pressure is measured at
1 m from the external surface of the unit in open field conditions.
(5) Internal exchanger water = 23/18°C; air entering external exchanger = 35°C
(6) Fresh air temperature = 7°C D.B. / 6°C W.B.; internal exchanger water temperature 30/35°C
Sizes
Length (A)
Width (B)
Height (C)
4 (A1)
(A2)
(B1)
(B2)
WSAT-XEE
Weight in oper.
WSAN-XEE
Weight in oper.
mm mm mm mm mm mm mm
Kg
Kg
700
700
700
700
82
1703
675
1209
305
315
The above data refer to standard units.
700
700
700
700
102
1703
675
1209
310
320
700
700
700
700
122
1703
675
1209
360
370
700
700
700
700
162
1932
1100
1417
520
530
700
700
700
700
182
1932
1100
1417
540
550
222
1932
1100
1417
700
700
700
700
570
580
700
700
700
700
262
2332
1100
1417
665
675
700
700
700
700
302
2332
1100
1417
680
690
CAUTION!
For trouble-free operation of the unit it is essential to maintain the safety distances indicated by the green areas.
Data contained in this document are not binding and may be changed by the Manufacturer without notice. No part of this publication may be reproduced.