HYDRONIC System HYDRONIC System The complete range of chillers, heat pumps and air handling units in large installations 72 HYDRONIC System is the innovative evolution of the traditional hydronic system. The cooling or thermal energy required for climate control is produced on a centralised level, then distributed – using chilled or hot water as a vector – in the serviced rooms via specific air treatment units and hydronic terminals, in partnership with the air renewal and purification units. System components series to size from name page Water chillers and Heat pumps - air source - axial fans WSAT-XEE / WSAN-XEE 82 302 ELFOEnergy Medium WSAT-XEE / WSAN-XEE 352 802 ELFOEnergy WSAT / WSAN 82 242 - 80D 240F SPINchiller2 WSAT-XSC2 / WSAN-XSC2 74 Large2 76 78 New 80 WSAT-XSC 270J 360L SPINchiller 82 WDATA 2.160 2.600 SCREWLine 84 WDATB 2.160 2.600 SCREWLine 86 WDAT-HT 2.180 2.600 SCREWLine 88 ELFOEnergy Small 90 Water chillers and Heat pumps - air source - centrifugal fans WSA-EE / WSN-EE 17 91 WSA-XEE / WSN-XEE 122 402 ELFOEnergy Duct Medium WRA / WRN 404 604 - 94 WSA-SC 65D 100D SPINchiller 96 98 New 92 Water chillers and Heat pumps - water source WSHF-XSC 65D 180F SPINsaver WRH / WRHN 102 422 - 100 WSH-XSC 65D 180F SPINchiller WDH-HE 2.220 2.600 SCREWLine 102 WDH 2.160 2.600 SCREWLine 106 REM 75C 2.440 - 108 ME 17 422 - 110 CE 25 602 - 112 New 104 Condenserless water chillers - air source MSE-SC 65D 180F SPINchiller 114 MDE 2.160 2.600 SCREWLine 116 CEM 75C 2.440 - 118 GPA M0 M9 - 120 GP1 / GP2 00 12 - 122 GP7 60 63 - 124 GPM 60 99 - 126 ELFOSpace OUT-V / OUT-H 3 31 ELFOSpace 128 ELFOSpace IN-V / IN-H 3 31 ELFOSpace 130 ELFOSpace BOX2 7 41 ELFOSpace 132 ELFOSpace WALL 3 17 ELFOSpace 134 ELFODuct CFD 7 41 ELFODuct 136 ELFODuct CFI 25 71 ELFODuct 138 ELFODuct CF 25 242 ELFODuct 140 ELFODuct CF-V 31 242 ELFODuct 142 14 803 - 144 - - - 146 Pumping units Water terminal units Air handling units AQ Remote management systems P-Matic for Hydronic 73 WSAT-XEE WSAN-XEE 82÷302 Water chiller ELFOENERGY MEDIUM 4WSAT-XEE: cooling only 4WSAN-XEE: reversible heat pump Air cooled Outdoor installation Capacity from 24,3 to 72,2 kW HYDRONIC Liquid chillers and heat pumps of the ELFOEnergy WSAT-XEE and WSAN-XEE series are units designed for outdoor installation and best energy efficiency in relation to their reduced size. The ELFOEnergy series has been the turning point in the evolution of chillers. Every unit has been conceived and made by applying state-of-the-art technology, emphasising the qualities of EFFICIENCY, SELF-ADAPTATION and EASY INSTALLATION that distinguish this product Thanks to its constructional and electronic peculiarities, ELFOEnergy permits: 4high energy efficiency, in particular during partial-load operation, thanks to the use of two compressors with different capacities that work on a single refrigerant circuit; 4Eurovent energy efficiency classification class "A" in heating operation, also in full load condition; 4adaptability of operating parameters to the load conditions of the connected system, thereby optimising consumption, efficiency and working life of the parts; 4easy, quick installation thanks to the standard hydronic group and the factory test carried out prior to dispatch; 4installation of hydronic group with non-standard working head pumps or with double pump. Eurovent Energy Efficiency Class functions and features AIR Cooling only (WSAT-XEE) Heating-Cooling (WSAN-XEE) FC R-410A Air cooled Outdoor inst. Refrig. R-410A Herm. Scroll ELFOControl Ice protection system (WSAN-XEE only) Free-Cooling (WSAT-XEE only) available configurations (1) WSAT-XEE S 82 (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) 400TN 1PUS - OHP - - - - - - - (1) LOW TEMPERATURE: 4S Standard 4B Low water temperature This version allows unit operation within the water and glycol mixing temperature range between +4°C and -8°C inclusive. 4DSPB Double set-point for water low temperature (Brine) (2) SUPPLY VOLTAGE: 4400TN 400/3/50+N (3) HYDRONIC GROUP USER SIDE: 41PUS Standard pump 41PUR Single pump with reduced discharge head 41PUM Single pump with larger discharge head 42PUS Standard double pump 42PUR Double pump with reduced discharge head 42PUM Double pump with larger discharge head 4Not required (4) ENERGY RECOVERY: 4Not required (Standard) 4D Partial recovery Carried out using braze-welded plate-type exchangers suited for recovering the desuperheating heat up to a maximum of 25% of the total unit heat. (5) OPERATION (WSAN-XEE only): 4OHP Operation in heat pump Cooling and heating unit (Standard) 4OHO Operation in heating-only Heating only unit 74 (6) CONDENSER COIL: 4CCS Standard condenser coil 4CCCA Condenser coil in copper/aluminium with acrylic coating 4CCCA1 Condenser coil in copper/aluminium with Energy Guard DCC Aluminium treatment 4CCCC Condenser coil in copper/copper (7) SOFT STARTER: 4Not required (Standard) 4SFSTR4N Device for inrush current reduction, for 400/3/50+N units (8) FREE CONTACTS HEATING EXTERNAL SIGNAL: 4Not required (Standard) 4CLSE Free Contacts External Signal (9) SHUNT CAPACITORS (POWER FACTOR > 0,9): 4Not required (Standard) 4PFCP Shunt capacitors (power factor > 0,9) (10) STORAGE TANK: 4Not required (Standard) 4ACC1 Teflon steel storage tank (11) FREE-COOLING (WSAT-XEE only): 4Not required (Standard) 4FCD Direct free-cooling For technological air conditioning, and when the air temperature permits, the free-cooling option makes it possible to recover cold energy from the outdoor environment (12) REDUCED OUT. SECT. FAN CONSUMPTION (WSAT-XEE only): 4Not required (Standard) 4CREFB Device for the reduction of ECOBREEZE type outdoor section fan consumption accessories ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 Control keypad for remote installation that repeats all the functions already present on the onboard microprocessor control ■ 4 Humidity probe for summer set point compensation according to the outside enthalpy and defrosting optimization in winter operation WSAT-XEE only: ■ 4 Setpoint compensation on the basis of outdoor enthalpy WSAN-XEE only: ■ 4 Setpoint compensation with outdoor air probe Rubber antivibration mounts Serial communication module with supervisor (MODBUS) Steel mesh filter on water side (when unit is in “without hydronic group” configuration) High and low pressure gauges Daily and weekly programming clock Finned coil protection grilles Phase monitor to check the presence and correct sequence of the power supply phases ■ 4 Key to symbols: HYDRONIC ■ Accessories supplied separately. technical data Sizes Application with terminal units WSAT-XEE 4Cooling capacity Total input EER EUROVENT ESEER Pump working head WSAN-XEE 4Cooling capacity Total input EER EUROVENT ESEER 4Heating capacity Total input COP EUROVENT Pump working head Application with radiant panels WSAN-XEE 4Cooling capacity Total input EER EUROVENT 4Heating capacity Total input COP EUROVENT Pump working head Number of refrigerant circuits Number and type of compressors Sound pressure level Power supply (1) (1)(2) (1) (1) (1) (1)(2) (1) (3) (2)(3) (3) (1) (4) (2)(4) (4) (5) (2)(5) (5) (4) (6) 82 102 122 162 182 222 262 302 kW kW kPa 24.3 8,90 2,73 4,32 132 28.2 10,4 2,72 4,48 126 33.7 12,5 2,71 4,18 120 40.0 14,2 2,81 4,20 104 45.9 16,7 2,74 4,34 88 54.4 20,1 2,71 4,47 148 64,1 23,4 2,74 4,19 139 72.2 26,6 2,71 4,06 131 kW kW kW kW kPa 23,6 9,36 2,52 4,07 28,8 9,00 3,20 136 27,5 10,9 2,53 4,11 32,9 10,3 3,18 129 32,7 13,0 2,51 3,85 37,5 11,7 3,21 125 39,4 15,3 2,57 3,82 45,6 14,1 3,23 107 45,6 17,8 2,56 4,00 53,0 16,5 3,21 89 52,9 21,0 2,51 4,11 61,9 19,0 3,26 150 63,0 25,0 2,52 3,90 72,4 22,2 3,27 141 71,9 28,4 2,53 3,86 83,7 25,6 3,27 131 kW kW kW kW kPa dB(A) V/Ph/Hz 31.5 9.95 3,16 29,2 7,07 4,13 91,8 36.7 11.9 3,09 33,6 8,00 4,21 80,4 43,8 14,4 3,05 38,0 9,10 4,15 72,7 52,6 16,8 3,13 46,9 11,2 4,19 42,9 60,2 18,9 3,18 54,1 13,3 4,07 17,2 72,3 22,7 3,18 63,3 15,6 4,05 111,2 83,1 26,6 3,13 74,0 18,2 4,07 102,3 97,2 30,5 3,19 85,4 21,1 4,05 82,9 62 64 64 1 2 SCROLL 60 60 Data referred to the following conditions: (1) Internal exchanger water = 12/7°C; air entering external exchanger = 35°C (2) Total input is obtained from the compressor input + fan input + auxiliary circuit input. (3) Ambient temperature = 7°C (R.H. = 85%); internal exchanger water outlet temperature 45°C 60 (4) (5) (6) 61 62 400/3/50+N Internal exchanger water = 23/18°C; air entering external exchanger = 35°C Fresh air temperature = 7°C D.B./ 6°C W.B.; internal exchanger water temperature 30/35°C Sound levels refer to units with full load under nominal test conditions. The sound pressure is measured at 1 m from the external surface of the unit in open field conditions. dimensions and clearances leave free C B1 CAUTION! A2 B B2 Sizes Length (A) Width (B) Height (C) 4(A1) (A2) (B1) (B2) WSAT-XEE Weight in oper. WSAN-XEE Weight in oper. mm mm mm mm mm mm mm 82 1703 675 1209 700 700 700 700 102 1703 675 1209 700 700 700 700 122 1703 675 1209 700 700 700 700 162 1932 1100 1417 700 700 700 700 182 1932 1100 1417 700 700 700 700 222 1932 1100 1417 700 700 700 700 262 2332 1100 1417 700 700 700 700 302 2332 1100 1417 700 700 700 700 kg 298 303 323 456 469 490 547 561 kg 315 320 370 530 550 580 675 690 The above data refer to standard units. A A1 For trouble-free operation of the unit it is essential to maintain the clearances in green. 75 WSAT-XEE WSAN-XEE Water chiller 352÷802 ELFOENERGY LARGE² 4WSAT-XEE: cooling only 4WSAN-XEE: reversible heat pump Air cooled Outdoor installation Capacity from 83,1 to 218 kW The Eurovent A Class ELFOEnergy Large² water chillers and heat pumps provide the highest seasonal efficiency. They're designed to be installed outdoor and feature uneven scroll compressors mounted in the same circuit, electronic expansion valves and high efficiency plate type evaporators. HYDRONIC ELFOEnergy Large² shows an unmatched seasonal efficiency ESEER and is available in two versions: EXCELLENCE and PREMIUM. The standard version EXCELLENCE offers the highest efficiency both at full and at part load. Also the PREMIUM version offers high efficiency at part load but favour also the compact dimensions being therefore extremely competitive. Thanks to its features, ELFOEnergy Large² offers: 4self-adaptability in different load conditions, thanks to the availability of several capacity steps and the adjustment logic developed for maximum efficiency and minimum wear 4very high overall reliability, thanks to the consolidated construction choices and the use of industrially-made products 4lower sound emissions, achieved thanks to the optimal sizing of the exchange surfaces and the use of high efficiency fans with “winglets” WSAT-XEE (cooling) WSAN-XEE (heating) Eurovent Energy Efficiency Class (Config. SC EXC) Eurovent Energy Efficiency Class (552÷802) 4quick and easy installation thanks to the quick connections with the main circuit, electrical wiring enablement and complete functional testing before delivery. The units can also be supplied with pump assemblies, partial heat recovery and inertial storage tank already installed on board, bringing together all the system's main components in a single solution. functions and features AIR Heating-Cooling Air cooled R-410A Outdoor inst. Refrig. R-410A Herm. Scroll Ice protection system FC ECO BREEZE HYDRO PACK Free-Cooling (WSAT-XEE only) ECOBreeze HydroPack EEV Electronic Expansion Valve available configurations (1) (2) WSAT-XEE EXC (1) VERSION: 4EXC EXCELLENCE (Standard) 4PRM PREMIUM (3) (4) - - (5) 352 (2) ENERGY RECOVERY: 4Not required (Standard) 4D Partial recovery Carried out using braze-welded plate-type exchangers suited for recovering the desuperheating heat up to a maximum of 25% of the total unit heat. In addition, exchangers are complete with antifreeze heater to protect against the risk of ice. 4R Total recovery Carried out using braze-welded plate-type exchangers suited for 100% recovery of condensation heat for producing hot water. In addition, exchangers are complete with safety differential pressure switch on the water side, antifreeze heater to protect against the risk of ice. (3) LOW TEMPERATURE: 4Not required (Standard) 4B Low water temperature This version allows unit operation within the water and glycol mixing temperature range between +4°C and -7°C inclusive. Two versions are available: 76 SC (6) (7) T CE - Unit for low temperatures only - Unit with double operating set-point (4) FREE-COOLING (WSAT-XEE only): 4Not required (Standard) 4FCD Direct Free-Cooling Version that allows cold to be recovered at no cost from the ambient when the external air temperature is lower than the system return water temperature. To avoid problems with the unit, the water system must be protected by a mixture of water and glycol based on the minimum temperatures which may occur at the place of installation. (5) ACOUSTIC CONFIGURATION: 4SC Compressor soundproofing This set-up is obtained by inserting the compressors in a soundproofed compartment. 4EN Super Silenced This configuration is reached by inserting the compressor in an soundproofed enclosure and reducing the fan speed. (6) ENERGY EFFICIENCY: 4T Temperate climate (Standard) (7) EXCHANGER APPROVALS: 4CE PED (European test) 4C Clivet (In-house test) 4 4 4 4 4 4 ■ 4 4 4 4 4 4 4 4 Free contacts for compressor status Free contact compressor state and local/remote management Switchboard ventilation Condenser coil in copper/aluminium with acrylic coating Copper/aluminium condensing coil with Energy Guard DCC Aluminium shell Copper/copper condenser coil Spring antivibration mounts Finned coil protection grilles Hail grilles Shut-off valve on compressor supply and return High and low pressure gauges Hydronic assembly with 1 x pump Hydronic assembly with 1 x pump + 1 x pump in stand-by Hydropack with 2 pumps 4 4 ■ 4 4 4 4 4 4 4 4 4 4 4 4 4 ■ 4 Storage tank Storage tank with onboard primary circuit Steel mesh filter on water side Set point compensation with 0-10 V signal Set point compensation with 4-20 mA signal Set point compensation with fresh air sensor Set point compensation with according to outdoor enthalpy Device for reducing consumption of the outdoor section fans of the ECOBreeze Phase monitor Multifunction phase monitor Soft Start Shunt capacitors (power factor > 0,9) MODBUS serial connection module BACNet serial connection module LonWorks serial connection module Unit microprocessor remote control interface kit Key to symbols: ■ Accessories supplied separately. technical data Sizs WSAT-XEE SC EXC 4 Cooling capacity SC EXC Total input SC EXC Total EER at 100% SC EXC ESEER SC EXC Sound pressure level SC PRM 4 Cooling capacity SC PRM Total input SC PRM EER EUROVENT SC PRM ESEER SC PRM Sound pressure level WSAN-XEE SC 4 Cooling capacity SC Total input SC Total EER at 100% SC ESEER SC 4 Heating capacity SC Total input SC COP SC 4 Cooling capacity SC Total input SC Total EER at 100% SC 4 Heating capacity SC Total input SC COP SC Sound pressure level Number of refrigerant circuits Number and type of compressors Power supply (1) (3) (1) kW kW dB(A) kW kW (3) (1) kW kW (2) (4) (5) (3) kW kW dB(A) kW kW kW dB(A) V/Ph/Hz 352 402 432 452 502 552 602 702 802 97,4 31,2 3,12 4,42 67 91,5 32,6 2,81 4,07 67 110 35,3 3,12 4,48 67 102 37,5 2,72 4,11 67 121 39,0 3,10 4,40 68 113 41,7 2,71 4,06 67 131 41,7 3,14 4,39 68 122 43,9 2,78 4,22 67 143 45,8 3,12 4,44 68 131 47,5 2,76 4,21 68 155 49,5 3,13 4,44 69 143 52,6 2,72 4,18 68 174 56,1 3,10 4,36 69 162 60,1 2,70 4,09 68 197 63,2 3,12 4,50 70 183 66,4 2,76 4,18 69 218 70,3 3,10 4,29 70 204 75,5 2,70 3,98 69 83,1 32,9 2,53 3,59 99,5 33,0 3,02 115 37,7 3,05 107 28,1 3,81 67 94,9 36,6 2,59 3,71 112 37,0 3,03 133 41,0 3,24 121 31,6 3,83 67 105 41,2 2,55 3,69 124 40,8 3,04 143 46,9 3,05 135 35,0 3,86 67 111 43,8 2,53 3,69 132 43,3 3,05 150 48,5 3,09 139 36,2 3,84 67 121 48,3 2,51 3,71 142 46,2 3,07 165 54,6 3,02 151 39,3 3,84 67 1 2 SCROLL 400/3/50 137 52,1 2,63 3,65 167 52,0 3,21 186 55,6 3,35 173 44,5 3,89 68 154 61,5 2,50 3,56 186 58,1 3,20 205 66,2 3,10 189 49,7 3,80 68 179 68,0 2,63 3,51 215 66,7 3,22 239 71,6 3,34 221 57,7 3,83 71 198 77,3 2,56 3,47 237 73,7 3,22 266 82,6 3,22 245 64,0 3,83 71 Data referred to the following conditions: (1) Internal exchanger water 12/7°C; ambient temperature 35°C (2) Internal exchanger water 40/45°C; air at external exchanger inlet 6,1°C W.B. (3) Sound levels refer to units with full load under nominal test conditions. The sound pressure is measured at (4) (5) 1 m from the external surface of the unit in open field conditions. Internal exchanger water 23/18°C; ambient temperature 35°C Internal exchanger water 30/35°C; air at external exchanger inlet 6,1°C W.B. dimensions and clearances leave free C A2 B1 B CAUTION! A B2 A1 For trouble-free operation of the unit it is essential to maintain the clearances in green. Sizes WSAT-XEE EXC Length (A) EXC Width (B) EXC Height (C) EXC Weight in oper. PRM Length (A) PRM Width (B) PRM Height (C) PRM Weight in oper. WSAN-XEE Length (A) Width (B) Height (C) Weight in oper. 4 (A1) (A2) (B1) (B2) 352 402 432 452 502 552 602 702 802 mm mm mm kg mm mm mm kg 3075 1097 1805 896 2710 1097 1805 778 3075 1097 1805 933 2710 1097 1805 802 3075 1097 1805 1024 2710 1097 1805 892 4025 1097 1805 1207 2710 1097 1805 924 4025 1097 1805 1234 2710 1097 1805 963 4025 1097 1805 1256 2710 1097 1805 984 4025 1097 1805 1302 3075 1097 1805 1087 5025 1097 1805 1497 4025 1097 1805 1295 5025 1097 1805 1544 4025 1097 1805 1324 mm mm mm kg 3075 1097 1805 915 3075 1097 1805 975 3075 1097 1805 1059 3075 1097 1805 1101 3075 1097 1805 1126 4025 1097 1805 1326 4025 1097 1805 1341 5025 1097 1805 1549 5025 1097 1805 1566 mm mm mm mm 1000 700 1350 1350 1000 700 1350 1350 1000 700 1350 1350 1000 700 1350 1350 1000 700 1350 1350 1000 700 1350 1350 1000 700 1350 1350 1000 700 1350 1350 1000 700 1350 1350 The above data refer to standard units. 77 HYDRONIC accessories WSAT WSAN 82÷242 Water chiller 4WSAT: cooling only 4WSAN: reversible heat pump HYDRONIC Air cooled Outdoor installation Capacity from 20,7 to 62,9 kW Liquid chillers and heat pumps of the WSAT and WSAN series are units designed for outdoor installation and best energy efficiency in relation to their reduced size. The availability of the double refrigerant and water circuit recommends use of this series for process applications. functions and features AIR Cooling only (WSAT) Heating-Cooling (WSAN) R-407C Air cooled Outdoor inst. Refrig. R-407C Herm. Scroll Ice protection system (WSAN only) available configurations WSAT 82 (1) (2) (3) B CE T (1) VERSION: 4S Standard 4B Low water temperature This version allows unit operation within the water and glycol mixing temperature range between +5°C and -8°C inclusive. (2) EXCHANGER APPROVALS: 4CE PED (European test). (3) ENERGY EFFICIENCY: 4T Temperate climate 78 accessories ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 Rubber antivibration mounts High and low pressure gauges Steel mesh filter on water side Manifold for single water circuit Remote control with remote microprocessor control Serial communication module PC/BMS MODBUS for 1 unit (Master) Serial communication module PC/BMS MODBUS from 2 to 254 units (Slave) Daily and weekly programming clock Phase monitor Coil protection grilles on external air side WSAT only: ■ 4 Device for operation at low outside temperatures with variable fan speed HYDRONIC ■ 4 Key to symbols: ■ Accessories supplied separately. technical data Sizes 4 Cooling capacity WSAT Total input WSAT Total EER at 100% WSAT ESEER WSAT 4 Heating capacity Total input COP Number of refrigerant circuits Number and type of compressors Sound pressure level Power supply (1) kW (1)(2) kW (1) (3) kW (2)(3) kW (4) dB(A) V/Ph/Hz 82 20,7 7,47 2,77 3,49 - 102 25,7 8,48 3,03 3,82 - 122 28,1 10,2 2,75 3,48 - 142 33,8 12,2 2,77 3,49 38,3 12,1 3,16 60 59 59 60 162 37,5 13,3 2,82 3,55 41,7 13,9 3,00 2 2 SCROLL 60 400/3/50+N 182 43,4 17,4 2,50 3,15 50,7 17,6 2,88 202 52,7 18,7 2,82 3,55 59,7 20,0 2,98 222 56,9 22,1 2,57 3,24 65,5 22,2 2,95 242 62,9 24,1 2,61 3,29 71,3 24,3 2,94 60 61 61 62 Data referred to the following conditions: (1) (2) (3) Internal exchanger water = 12/7°C; ambient temperature = 35°C Total input is obtained from compressor input + fan input. Ambient temperature = 7°C (R.H. = 85%); internal exchanger water outlet temperature 45°C 4) Sound levels refer to units with full load under nominal test conditions. The sound pressure is measured at 1 m from the external surface of the unit in open field conditions. Series WSAT and WSAN derive from the corresponding series ELFOEnergy Medium functional spaces dimensions and clearances Sizes Length (A) Width (B) Height (C) 4(A1) (A2) (B1) (B2) Weight in oper. C mm mm mm mm mm mm mm kg 82 1435 678 1000 800 800 800 800 220 102 1530 678 1530 800 800 800 800 275 122 1530 678 1530 800 800 800 800 280 142 1563 1107 1570 900 900 900 900 380 162 1563 1107 1570 900 900 900 900 480 182 1563 1107 1570 900 900 900 900 485 202 2098 1107 1570 900 900 900 900 580 222 2098 1107 1570 900 900 900 900 585 242 2098 1107 1570 900 900 900 900 590 The above data refer to standard units. A2 B1 B CAUTION! B2 A A1 For trouble-free operation of the unit it is essential to maintain the clearances in green. 79 WSAT-XSC2 WSAN-XSC2 Water chiller 80D÷240F SPINCHILLER2 4WSAT-XSC2: cooling only 4WSAN-XSC2: reversible heat pump Air cooled Outdoor installation Capacity from 197 to 657 kW NEW The Eurovent A Class SPINchiller2 water chillers and heat pumps provide the highest seasonal efficiency. They're designed to be installed outdoor and feature uneven scroll compressors mounted in the same circuit, electronic expansion valves and high efficiency plate type evaporators. HYDRONIC SPINchiller² shows an unmatched seasonal efficiency ESEER and is available in two versions: EXCELLENCE and PREMIUM. The standard version EXCELLENCE offers the highest efficiency both at full and at part load. Also the PREMIUM version offers high efficiency at part load but favour also the compact dimensions being therefore extremely competitive. Thanks to its features, SPINchiller² offers: 4 selfadaptivity in different load conditions, thanks to high number of capacity steps and to the management logic that has been developed to increase the efficiency and reduce the wear of the compressors; 4 high unit reliability, thanks to the double refrigerant circuit, to the proven architecture and to the components produced at high volumes; 4 low noise, thanks to the sizing of the coil and to the high efficiency fans having "winglets" blade profiles; WSAT-XSC2 (cooling) Eurovent Energy Efficiency Class (Config. SC EXC) 4 easy and quick installation, thanks to the quick connections to the system, to the easy electrical connections and to the complete functional test undertaken before the shipment. The units can also be supplied with inbuilt pumps, desuperheater and storage tank, allowing all the main components of the plant to be in the unit. WSAN-XSC2 (heating) Eurovent Energy Efficiency Class (Config. EXC) Eurovent Energy Efficiency Class (Config. PRM) functions and features AIR Cooling only (WSAT-XSC2) Heating-Cooling (WSAN-XSC2) Air cooled R-410A Outdoor inst. Refrig. R-410A Herm. Scroll Ice protection system FC ECO BREEZE HYDRO PACK Free-Cooling (WSAT-XSC2 only) ECOBreeze HydroPack EEV Electronic Expansion Valve available configurations (1) (2) WSAT-XSC2 EXC (1) VERSION: 4EXC EXCELLENCE (Standard) 4PRM PREMIUM (3) (4) - - (5) 80D (2) ENERGY RECOVERY: 4Not required 4D Partial recovery Carried out using braze-welded plate-type exchangers suited for recovering the desuperheating heat up to a maximum of 20% of the total unit heat. In addition, exchangers are complete with antifreeze heater to protect against the risk of ice. 4R Total recovery Carried out using braze-welded plate-type exchangers suited for 100% recovery of condensation heat for producing hot water. In addition, exchangers are complete with antifreeze heater to protect against the risk of ice. (3) LOW TEMPERATURE: 4Not required (Standard) 4B Low water temperature This version allows unit operation within the water and glycol mixing temperature range between +4°C and -7°C inclusive. Two versions are available: - Unit for low temperatures only 80 SC (6) CE - Unit with double operating set-point The possibility of reducing the cooling capacity depends on the working temperature. (4) FREE-COOLING (WSAT-XSC2 only): 4Not required (Standard) 4FCD Direct Free-Cooling Version that allows cold to be recovered at no cost from the ambient when the external air temperature is lower than the system return water temperature. To avoid problems with the unit, the water system must be protected by a mixture of water and glycol based on the minimum temperatures which may occur at the place of installation. (5) ACOUSTIC CONFIGURATION: 4SC Compressor soundproofing This set-up is obtained by inserting the compressors in a soundproofed compartment. 4EN Super Silenced This set-up is obtained by soundproofing the compressor compartment even more and reducing the fan speed of rotation. (6) EXCHANGER APPROVALS: 4CE PED (European test) 4C Clivet (In-house test) 4 4 4 4 ■ 4 4 4 4 4 4 4 4 4 4 4 Switchboard ventilation Condenser coil in copper/aluminium with acrylic coating Condenser coil in copper/aluminium with Energy Guard DCC Aluminium coating Copper/copper condenser coil Spring antivibration mounts Finned coil protection grilles Hail grilles Shut-off valve on compressor supply and return High and low pressure gauges Hydronic group with 1 pump Hydronic group with 1 pump + 1 stand by HydroPack with 2 pumps HydroPack with 3 pumps Storage tank Storage tank with onboard primary circuit ■ 4 4 4 4 4 4 4 4 4 4 4 4 4 ■ 4 4 Steel mesh filter on water side Set point compensation with 0-10 V signal Set point compensation with 4-20 mA signal Set point compensation with fresh air sensor Set point compensation with according to outdoor enthalpy Device for reducing consumption of the outdoor section fans of the ECOBreeze Phase monitor Multifunction phase monitor Soft Start Shunt capacitors (power factor > 0,9) MODBUS serial connection module BACNet serial connection module LonWorks serial connection module Remote control with remote microprocessor control Master-slave operation Key to symbols: ■ Accessories supplied separately. technical data Sizes WSAT-XSC2 SC EXC 4 Cooling capacity SC EXC Total input SC EXC Total EER at 100% SC EXC ESEER SC EXC Sound pressure level SC PRM 4 Cooling capacity SC PRM Total input SC PRM Total EER at 100% SC PRM ESEER SC PRM Sound pressure level WSAN-XSC2 SC EXC 4 Cooling capacity SC EXC Total input SC EXC Total EER at 100% SC EXC ESEER SC EXC 4 Heating capacity SC EXC Total input SC EXC COP SC PRM 4 Cooling capacity SC PRM Total input SC PRM Total EER at 100% SC PRM ESEER SC PRM 4 Heating capacity SC PRM Total input SC PRM COP Number of refrigerant circuits Number and type of compressors Power supply (1) (3) (1) (3) (1) (2) (1) (2) 80D 90D 100D 110D 120D 140D 160D 170E 180F 200F 220F 240F kW kW dB(A) kW kW dB(A) 212 67,7 3,13 4,63 71 197 72,5 2,72 4,20 65 254 81,4 3,12 4,55 71 224 86,1 2,61 4,10 66 281 90,6 3,10 4,46 72 254 93,1 2,73 4,21 66 309 99,5 3,10 4,44 73 282 104 2,72 4,22 67 349 112 3,11 4,37 73 320 116 2,75 4,12 67 392 125 3,14 4,60 74 360 132 2,73 3,93 68 436 140 3,11 4,46 74 400 147 2,73 3,88 68 474 153 3,10 4,57 74 444 164 2,70 4,12 69 518 166 3,13 4,62 74 471 177 2,66 4,05 69 562 181 3,10 4,63 74 517 190 2,72 4,08 69 614 194 3,17 4,60 74 544 209 2,60 4,11 70 657 210 3,13 4,44 75 596 220 2,71 4,14 70 kW kW 204 75,4 2,71 4,38 230 71,5 3,22 194 77,5 2,51 4,13 219 69,9 3,13 243 89,4 2,72 4,39 280 87,5 3,20 225 89,2 2,52 4,10 260 85,0 3,06 265 97,6 2,72 4,40 309 95,8 3,23 250 99,4 2,52 4,12 280 92,2 3,04 291 107 2,72 4,36 343 107 3,22 268 112 2,40 3,76 305 100 3,05 329 120 2,74 4,15 384 120 3,21 317 124 2,52 3,79 349 116 3,01 372 136 2,74 4,31 430 133 3,24 355 141 2,51 3,92 393 130 3,03 419 153 2,74 4,06 488 149 3,28 397 158 2,51 3,52 432 143 3,02 456 165 2,77 4,40 519 161 3,23 - 487 179 2,73 4,36 565 174 3,24 - 534 195 2,74 4,30 625 191 3,27 - 572 211 2,72 4,25 679 206 3,29 - 622 229 2,72 4,18 732 223 3,28 - kW kW kW kW kW kW V/Ph/Hz 2 4 SCROLL 6 SCROLL 5 SCROLL 400/3/50 Data referred to the following conditions: (1) (2) Internal exchanger water = 12/7°C; ambient temperature = 35°C Internal exchanger water = 40/45°C; air at external exchanger inlet = 6,1°C W.B. (3) (4) Sound levels refer to units with full load under nominal test conditions. The sound pressure is measured at 1 m from the external surface of the unit in open field conditions. Internal exchanger water = 15/10°C; glycol 30% dimensions and clearances leave free C A1 A A2 B1 B B2 Sizes WSAT-XSC2 SC/EN EXC Length (A) SC/EN EXC Width (B) SC/EN EXC Height (C) SC/EN EXC Weight in oper. SC/EN PRM Length (A) SC/EN PRM Width (B) SC/EN PRM Height (C) SC/EN PRM Weight in oper. WSAN-XSC2 SC/EN EXC Length (A) SC/EN EXC Width (B) SC/EN EXC Height (C) SC/EN EXC Weight in oper. SC/EN PRM Length (A) SC/EN PRM Width (B) SC/EN PRM Height (C) SC/EN PRM Weight in oper. 80D 90D 100D 110D 120D 140D 160D 170E 180F 200F 220F 240F mm mm mm kg mm mm mm kg 5800 1097 1825 1784 4800 1097 1825 1612 5800 1097 1825 2057 4800 1097 1825 1892 5800 1115 2221 2171 5800 1097 1825 2102 5800 1115 2221 2329 5800 1097 1825 2213 5800 1115 2221 2397 5800 1097 1825 2259 3800 2228 2221 2821 5800 1115 2221 2311 4750 2228 2246 3125 5800 1115 2221 2423 4750 2228 2246 3490 3800 2228 2221 2915 5800 2228 2246 4146 3800 2228 2221 3097 5800 2228 2246 4297 4750 2228 2246 3515 5800 2228 2246 4525 4750 2228 2246 3558 5800 2228 2246 4571 4750 2228 2246 3787 mm mm mm kg mm mm mm kg 2850 2233 2250 1877 4800 1097 1825 1805 2850 2233 2250 2078 5800 1097 1825 2133 3800 2233 2250 2502 5800 1097 1825 2325 3800 2233 2250 2658 5800 1097 1825 2399 3800 2233 2250 2707 5800 1120 2250 2362 4750 2233 2250 3608 5800 1120 2250 2466 4750 2233 2250 3765 5800 1120 2250 2512 5800 2233 2250 4591 - 5800 2233 2250 4792 - 5800 2233 2250 4972 - 5800 2233 2250 5216 - 5800 2233 2250 5267 - The above data refer to standard units. CAUTION! For trouble-free operation of the unit it is essential to maintain the clearances in green. Please refer to the technical bulletin of the unit for the required clearances 81 HYDRONIC accessories WSAT-XSC 270J÷360L Water chiller Air cooled Outdoor installation Capacity from 692 to 965 kW SPINCHILLER The SPINchiller series presents a new concept of chiller offering: HYDRONIC 4EFFICIENCY that increases as the heating load decreases, while guaranteeing maximum requested load when necessary. SPINchiller always ensures maximum comfort with very high efficiency and consequently considerable energy savings; 4a modular approach. Several basic units may be connected together to form a single structure according to the required capacity. This allows high production standardisation and therefore utmost operating RELIABILITY; 4simple unit-system combination, since these units are SELF-ADAPTING to the characteristics of the actual system, thereby avoiding delicate, timeconsuming calibrations. Easy connection to the service system plus a simple control system and easy maintenance drastically reduce work requiring specialised personnel with consequent reduction in installation costs; 4extended operating limits to keep the system running, even under exceptional start-up and load conditions; 4customisation of the unit, also for special requirements both in the civil and technological air-conditioning sphere, thanks to the many available optional accessories. The ECOBreeze and HydroPack accessories in particular enhance the qualities of flexibility and energy efficiency. The latter, for example, consistent with the concept of modularity, has two pumps in parallel to monitor the system load variations better and to regulate the water flow in the critical system starting (or restarting) stages so that outside servicing is avoided. The innovative and hi-tech features of SPINchiller give this series a much higher quality than can generally be found on the market today. functions and features AIR Cooling only R-410A Air cooled Outdoor inst. Refrig. R-410A Herm. scroll FC ECO BREEZE HYDRO PACK Free-Cooling ECOBreeze HydroPack EEV Electronic Expansion Valve available configurations (1) (2) (3) (4) WSAT-XSC D B 200H ST (1) ENERGY RECOVERY: 4Not required 4D Partial recovery Carried out using braze-welded plate-type exchangers suited for recovering the desuperheating heat up to a maximum of 20% of the total unit heat. 4R Total recovery Carried out using braze-welded plate-type exchangers suited for 100% recovery of condensation heat for producing hot water. (2) LOW TEMPERATURE: 4B Low water temperature This version allows unit operation within the water and glycol mixing temperature range between +4°C and -7°C inclusive. Two versions are available - Unit for low temperatures only - Unit with double operating set-point The possibility of reducing the cooling capacity depends on the working temperature. Check with our sales office. (5) (6) T C (3) ENERGY SAVING: 4FCD Direct Free-Cooling Version that allows cold to be recovered at no cost from the ambient when the external air temperature is lower than the system return water temperature. To avoid problems with the unit, the water system must be protected by a mixture of water and glycol based on the minimum temperatures which may occur at the place of installation. (4) ACOUSTIC CONFIGURATION: 4ST Standard 4SC Compressor soundproofing This set-up is obtained by inserting the compressors in a soundproofed compartment. 4EN Super Silenced This set-up is obtained by soundproofing the compressor compartment even more and reducing the fan speed of rotation with an uprated condensing section. (5) ENERGY EFFICIENCY: 4T Temperate climate (Standard) (6) EXCHANGER APPROVALS: 4CE PED (European test) 4C Clivet (In-house test) 82 accessories 4 ■ 4 4 4 4 4 4 ■ 4 4 4 4 4 4 Condenser coil in copper/aluminium with acrylic coating Copper/copper condenser coil Spring antivibration mounts Compressor compartment and condenser coil protection grilles Shut-off valve on compressor supply and return High and low pressure gauges HydroPack with 2 pumps User side anti-ice electric heaters for hydronic group Steel mesh filter on water side Set point compensation with 4-20 mA signal Set point compensation with fresh air sensor Set point compensation with according to outdoor enthalpy Device for reducing consumption of the outdoor section fans of the ECOBreeze Phase monitor 4 4 4 4 ■ 4 ■ 4 4 ■ 4 Shunt capacitors (power factor > 0,9) Soft Start CAN/MODBUS serial converter kit CAN/LonWorks serial converter kit Data logger Master-slave operation Free contacts for compressor status Remote control with remote microprocessor control HYDRONIC 4 Key to symbols: ■ Accessories supplied separately. technical data Sizes 4 Cooling capacity ST/SC (1) ST/SC Total input ST/SC EER EUROVENT ST/SC ESEER ST Sound pressure level (2) SC Sound pressure level (2) EN (1) 4 Cooling capacity EN Total input EN EER EUROVENT EN ESEER EN Sound pressure level (2) FREE-COOLING SC Free-Cooling rated output (3) SC Air temp. with Free-Cooling at 100% Number of refrigerant circuits Number and type of compressors Power supply kW kW dB(A) dB(A) kW kW dB(A) kW °C V/Ph/Hz 270J 692 251 2,75 4,51 81 77 665 257 2,58 4,59 71 300L 748 272 2,74 4,58 81 78 719 282 2,55 4,61 72 315L 797 289 2,76 4,60 81 78 761 298 2,55 4,61 72 330L 860 309 2,78 4,64 82 78 819 320 2,55 4,62 73 345L 910 328 2,78 4,64 82 79 862 337 2,56 4,63 73 360L 965 349 2,76 4,62 82 79 925 358 2,58 4,67 73 696 -6,3 754 -5,3 820 -5,8 878 -6,3 911 -1,9 965 -2,2 4 10 SCROLL 12 SCROLL 400/3/50 Data referred to the following conditions: (1) (2) Internal exchanger water 12/7°C; ambient temperature 35°C Sound levels refer to units with full load under nominal test conditions. The sound pressure is measured at 1 m from the external surface of the unit in open field conditions. (3) Internal exchanger water 15/10°C; glycol 30% dimensions and clearances leave free C A2 B1 A B B2 CAUTION! Sizes ST/SC Length (A) ST/SC Width (B) ST/SC Height (C) ST/SC 4 (A1) ST/SC (A2) ST/SC (B1) ST/SC (B2) ST Weight in oper. SC Weight in oper. EN Weight in oper. mm mm mm mm mm mm mm kg kg kg 270J 5708 2233 2280 1690 700 1100 1100 5358 5570 5570 300L 6658 2233 2280 1690 700 1100 1100 6023 6266 6266 315L 6658 2233 2280 1690 700 1100 1100 6080 6324 6324 330L 6658 2233 2280 1690 700 1100 1100 6114 6357 6357 345L 7608 2233 2280 1690 700 1100 1100 6511 6745 6745 360L 7608 2233 2280 1690 700 1100 1100 6567 6800 6800 The above data refer to standard units. A1 For trouble-free operation of the unit it is essential to maintain the clearances in green. 83 WDATA 2.160÷2.600 Water chiller Air cooled Outdoor installation Capacity from 432 to 1411 kW SCREWLINE HYDRONIC The experience gained by Clivet in the high-capacity chiller sector has resulted in the WDATA range, with the following features: 4EFFICIENCY - New high capacity screw compressors (over 1400 kW with 2 compressors), water-cooled shell-and-tube exchangers specially developed for the gas R-134a. The air-cooled exchangers have been designed and made directly by CLIVET to ensure best adaptation to the other refrigerant circuit parts. The compressors are managed with continual adjustment of the capacity and are fitted with an economiser circuit for further operating efficiency. In this way, the best result is achieved, highlighting the performance and reducing costs; all the series is in the ENERGETIC CLASS "A", with performances over 3.1; 4SELF-ADAPTATION - New, modern and intelligent electronic control directly developed by Clivet. This customisation allows better management of all the circuit components. Continual adapting of chiller operating parameters to the load conditions of the system in which it is installed reduces consumption and noise level, while the working life of the parts increases; Unit listed on www.eurovent-certification.com 4STURDINESS - Load-bearing frame in enamelled hot-galvanised sheet metal with semi-hermetic double-screw compressors and shell-and-tube evaporator ensuring reliability and constant performance. All the finishes are meticulously applied to ensure the utmost weathering resistance even under extreme conditions of use. Eurovent Energy Efficiency Class functions and features AIR Cooling only R-134a Air cooled Outdoor inst. Refrig. R-134a Twin-screw semi. FC ECO BREEZE HYDRO PACK Free-Cooling ECOBreeze HydroPack EEV Electronic Expansion Valve available configurations WDATA (1) (2) (3) D B - 2.160 (4) (5) (6) ST T C (1) ENERGY RECOVERY: 4Standard 4D Partial recovery Carried out using tube bundle exchargers suited for recovering the desuperheating heat up to a maximum of 20% of the total unit heat. 4R Total recovery Carried out using tube bundle exchargers suited for 100% recovery of condensation heat for producing hot water. This version is supplied as standard with a variable-speed low temperature device. (2) LOW TEMPERATURE: 4Not required 4B Low water temperature This version allows unit operation within the water and glycol mixing temperature range between +4°C and -7°C inclusive. Two versions are available: - Unit for low temperatures only - Unit with double operating set-point The possibility of reducing the cooling capacity depends on the working temperature. 84 (3) ENERGY SAVING: 4Standard 4FCD Direct Free-Cooling Version that allows cold to be recovered at no cost from the ambient when the external air temperature is lower than the system return water temperature. (4) ACOUSTIC CONFIGURATION: 4ST Standard 4SC Compressor soundproofing This set-up is obtained by inserting the compressors in a soundproofed compartment. 4LN Silenced This set-up is obtained by inserting the compressors in a soundproofed compartment and reducing the fan speed of rotation with an uprated condensing section. (5) ENERGY EFFICIENCY: 4T Temperate climate (Standard) (6) EXCHANGER APPROVALS: 4CE PED (European test) 4C Clivet (In-house test) accessories 4 4 ■ 4 4 4 4 4 4 4 4 4 Condenser coil in copper/aluminium with acrylic coating Copper/copper condenser coil Condenser coil in copper/aluminium with Energy Guard DCC Aluminium treatment Spring antivibration mounts Compressor compartment and condenser coil protection grilles HydroPack with 2 pumps HydroPack with 3 pumps Set point compensation with 4-20 mA signal Set point compensation with 0-10 V signal Set point compensation with fresh air sensor Set point compensation with according to outdoor enthalpy Device for reducing consumption of the outdoor section variable speed fans (phase-cut) 4 4 4 4 4 4 4 ■ 4 4 4 Device for reducing consumption of the outdoor section fans of the ECOBreeze Magnetothermal circuit breakers Shunt capacitors (power factor > 0,9) MODBUS serial connection module BACNet serial connection module LonWorks serial connection module Master-slave operation Remote control with remote microprocessor control Compressor suction shut-off valves Soft Start HYDRONIC 4 Key to symbols: ■ Accessories supplied separately. technical data Sizes Eurovent (*) (1) ST/SC4 Cooling capacity ST/SC Total input ST/SC EER EUROVENT ST/SC ESEER ST Sound pressure level (2) SC Sound pressure level (2) (1) LN 4 Cooling capacity LN Total input LN EER EUROVENT LN ESEER LN Sound pressure level (2) FREE-COOLING SC Free-Cooling rated output (3) SC Air temp. with Free-Cooling at 100% LN Free-Cooling rated output (3) LN Air temp. with Free-Cooling at 100% Number of refrigerant circuits Number and type of compressors (4) Power supply 2.160 2.180 2.190 2.200 564 180 3,13 3,94 78 75 561 180 3,12 4,01 72 2.240 616 198 3,11 3,93 78 76 614 198 3,10 4,04 72 2.280 699 225 3,11 4,02 78 76 694 224 3,10 4,12 73 2.300 767 247 3,11 4,02 79 76 769 247 3,11 4,12 73 2.320 835 268 3,12 4,09 79 76 829 267 3,10 4,16 73 2.340 882 284 3,11 4,09 79 76 877 281 3,12 4,12 73 2.360 935 300 3,12 4,14 80 77 932 299 3,12 4,14 74 2.440 1016 328 3,10 3,96 81 78 1020 329 3,10 4,15 75 2.480 1138 366 3,11 4,04 81 78 1143 368 3,11 4,15 76 2.540 1272 408 3,12 4,03 82 79 1287 413 3,12 4,13 76 2.600 1411 452 3,12 4,08 82 79 - kW kW dB(A) dB(A) kW kW dB(A) 435 140 3,11 3,83 77 74 432 138 3,13 3,95 71 471 150 3,14 3,73 77 74 467 150 3,11 3,93 71 522 167 3,13 3,89 78 75 517 165 3,13 3,94 72 kW °C kW °C - 458 0,0 454 -2,0 492 -0,5 488 -1,9 546 -1,0 541 -1,6 590 -2,0 586 -2,2 641 -1,0 639 -3,3 724 -2,5 718 -5,1 795 -3,8 793 -6,8 864 -5,1 851 -8,0 915 -6,2 909 -4,3 970 -7,1 960 -5,0 1050 -3,7 1055 -6,5 1182 -5,5 1184 -4,6 1320 -3,5 1334 -6,5 1463 -5,0 - 2 2 DSW 400/3/50 V/Ph/Hz Data referred to the following conditions: (*) The programme applies to air-cooled water chillers up to 600 kW and water-cooled water chillers up to 1500 kW. Internal exchanger water = 12/7°C; external air temperature 35°C Sound levels refer to units with full load under nominal test conditions. The sound pressure is measured at (1) (2) (3) (4) 1 m from the external surface of the unit in open field conditions. Internal exchanger water = 15/10°C; glycol 30% DSW = twin-screw compressor dimensions and clearances leave free C A2 A B1 Sizes ST/SC Length (A) ST/SC Width (B) ST/SC Height (C) 4 (A1) ST/SC ST/SC (A2) ST/SC (B1) ST/SC (B2) ST Weight in oper. SC Weight in oper. LN LN LN CAUTION! LN For trouble-free operation of the unit it is essential to LN maintain the clearances in green. LN LN LN B B2 A1 Length (A) Width (B) Height (C) 4 (A1) (A2) (B1) (B2) Weight in oper. mm mm mm mm mm mm mm kg kg 2.160 5704 2239 2220 1690 700 1100 1100 4447 4727 2.180 5704 2239 2220 1690 700 1100 1100 4460 4740 2.190 5704 2239 2220 1690 700 1100 1100 4732 5012 2.200 5704 2239 2220 1690 700 1100 1100 5089 5369 2.240 6654 2239 2220 1690 700 1100 1100 5260 5626 2.280 6654 2239 2220 1690 700 1100 1100 5282 5648 2.300 6654 2239 2370 1690 700 1100 1100 5589 5939 2.320 6654 2239 2370 1690 700 1100 1100 6095 6414 2.340 7612 2239 2400 1690 700 1100 1100 6424 6844 2.360 7612 2239 2400 1690 700 1100 1100 6940 7360 2.440 9512 2239 2400 1690 700 1100 1100 7522 7942 2.480 9512 2239 2400 1690 700 1100 1100 8486 9019 2.540 11414 2239 2400 1690 700 1100 1100 9487 9829 2.600 11414 2239 2400 1690 700 1100 1100 10021 10363 mm mm mm mm mm mm mm kg 5704 2239 2220 1690 700 1100 1100 4727 5704 2239 2220 1690 700 1100 1100 4856 6654 2239 2220 1690 700 1100 1100 5403 6654 2239 2220 1690 700 1100 1100 5817 6654 2239 2220 1690 700 1100 1100 5933 6654 2239 2220 1690 700 1100 1100 5955 7612 2239 2400 1690 700 1100 1100 6577 7612 2239 2400 1690 700 1100 1100 6970 9512 2239 2400 1690 700 1100 1100 7490 9512 2239 2400 1690 700 1100 1100 7859 9512 2239 2400 1690 700 1100 1100 8251 11414 2239 2400 1690 700 1100 1100 9652 11414 2239 2400 1690 700 1100 1100 10301 - The above data refer to standard units. 85 WDATB 2.160÷2.600 Water chiller Air cooled Outdoor installation Capacity from 375 to 1384 kW SCREWLINE HYDRONIC The experience gained by Clivet in the high-capacity chiller sector has resulted in the WDATB range, with the following features: 4EFFICIENCY - New high capacity screw compressors (over 1380 kW with 2 compressors), water-cooled shell-and-tube exchangers specially developed for the gas R-134a. The air-cooled exchangers have been designed and made directly by CLIVET to ensure best adaptation to the other refrigerant circuit parts. The compressors are managed with continual adjustment of the capacity and are fitted with an economiser circuit for further operating efficiency. In this way, the best result is achieved, highlighting the performance and reducing costs; all the series is in the ENERGETIC CLASS "B" 4SELF-ADAPTATION - New, modern and intelligent electronic control directly developed by Clivet. This customisation allows better management of all the circuit components. Continual adapting of chiller operating parameters to the load conditions of the system in which it is installed reduces consumption and noise level, while the working life of the parts increases; Unit listed on www.eurovent-certification.com 4STURDINESS - Load-bearing frame in enamelled hot-galvanised sheet metal with semi-hermetic double-screw compressors and shell-and-tube evaporator ensuring reliability and constant performance. All the finishes are meticulously applied to ensure the utmost weathering resistance even under extreme conditions of use. Eurovent Energy Efficiency Class (Config. ST, SC, LN, EN) functions and features AIR Cooling only R-134a Air cooled Outdoor inst. Refrig. R-134a Twin-screw semi. FC ECO BREEZE HYDRO PACK Free-Cooling ECOBreeze HydroPack EEV Electronic Expansion Valve available configurations WDATB (1) (2) (3) D B - 2.160 (4) (5) (6) ST T C (1) ENERGY RECOVERY: 4Standard 4D Partial recovery Carried out using tube bundle exchargers suited for recovering the desuperheating heat up to a maximum of 20% of the total unit heat. 4R Total recovery Carried out using tube bundle exchargers suited for 100% recovery of condensation heat for producing hot water. This version is supplied as standard with a variable-speed low temperature device. (2) LOW TEMPERATURE: 4Not required 4B Low water temperature This version allows unit operation within the water and glycol mixing temperature range between +4°C and -7°C inclusive. Two versions are available: - Unit for low temperatures only - Unit with double operating set-point The possibility of reducing the cooling capacity depends on the working temperature. (3) ENERGY SAVING: 4Standard 4FCD Direct Free-Cooling Version that allows cold to be recovered at no cost from the ambient when the external air temperature is lower than the system return water temperature. 86 To avoid problems with the unit, the water system must be protected by a mixture of water and glycol based on the minimum temperatures which may occur at the place of installation. (4) ACOUSTIC CONFIGURATION: 4ST Standard 4SC Compressor soundproofing This set-up is obtained by inserting the compressors in a soundproofed compartment. 4LN Silenced This set-up is obtained by inserting the compressors in a soundproofed compartment and reducing the fan speed of rotation with an uprated condensing section. 4EN Super Silenced With reference to the LN set-up, the fan speed of rotation is reduced even more with a larger condensing section and the Kit for Low Outdoor Temperature is standard supply with variable speed fans. The compressors are enclosed in a soundproofed compartment. 4CN Compact Super Lownoise With reference to the LN version the fanspeed is reduced and the low ambient kit with fan at variable speed is supplied as a standard. The compressors are enclosed in a soundproof compartment. (5) ENERGY EFFICIENCY: 4T Temperate climate (Standard) (6) EXCHANGER APPROVALS: 4CE PED (European test) 4C Clivet (In-house test) accessories 4 4 ■ 4 4 4 4 4 4 4 4 4 Condenser coil in copper/aluminium with acrylic coating Copper/copper condenser coil Condenser coil in copper/aluminium with Energy Guard DCC Aluminium treatment Spring antivibration mounts Compressor compartment and condenser coil protection grilles HydroPack with 2 pumps HydroPack with 3 pumps Set point compensation with 4-20 mA signal Set point compensation with 0-10 V signal Set point compensation with fresh air sensor Set point compensation with according to outdoor enthalpy Device for reducing consumption of the outdoor section variable speed fans (phase-cut) 4 4 4 4 4 4 4 ■ 4 4 4 Device for reducing consumption of the outdoor section fans of the ECOBreeze Magnetothermal circuit breakers Shunt capacitors (power factor > 0,9) MODBUS serial connection module BACNet serial connection module LonWorks serial connection module Master-slave operation Remote control with remote microprocessor control Compressor suction shut-off valves Soft Start HYDRONIC 4 Key to symbols: ■ Accessories supplied separately. technical data Sizes Eurovent (*) ST/SC4 Cooling capacity (1) ST/SC Total input ST/SC EER EUROVENT ST/SC ESEER ST Sound pressure level (2) SC Sound pressure level (2) LN 4 Cooling capacity (1) LN Total input LN EER EUROVENT LN ESEER LN Sound pressure level (2) EN 4 Cooling capacity (1) EN Total input EN EER EUROVENT EN ESEER EN Sound pressure level (2) CN 4 Cooling capacity (1) CN Total input CN EER EUROVENT CN ESEER CN Sound pressure level (2) FREE-COOLING SC Free-Cooling rated output (3) SC Air temp. with Free-Cooling at 100% LN Free-Cooling rated output (3) LN Air temp. with Free-Cooling at 100% Number of refrigerant circuits Number and type of compressors (4) Power supply 2.160 2.180 2.190 2.200 2.240 588 202 2,91 3,84 78 75 584 201 2,91 3,90 72 590 203 2,91 3,86 66 545 216 2,52 3,42 67 2.280 669 231 2,90 3,85 78 75 662 228 2,90 3,91 73 668 230 2,90 3,89 68 617 245 2,52 3,44 68 2.300 751 258 2,91 3,88 79 76 743 256 2,90 3,93 73 744 256 2,91 3,96 68 681 268 2,55 3,49 69 2.320 807 278 2,90 3,90 79 76 801 275 2,91 3,97 73 796 272 2,93 4,03 68 730 288 2,53 3,42 69 2.340 855 294 2,90 4,00 79 76 855 294 2,90 4,04 73 851 293 2,90 4,05 68 775 310 2,50 3,42 69 2.360 905 309 2,92 3,99 80 77 895 309 2,90 3,98 74 893 306 2,92 4,03 68 830 330 2,52 3,36 69 2.440 994 343 2,90 3,93 81 78 991 342 2,90 3,93 75 996 342 2,91 3,97 69 910 364 2,50 3,48 70 2.480 1108 382 2,90 3,91 81 78 1112 383 2,90 3,93 76 1099 378 2,91 4,00 70 1020 404 2,53 3,35 71 2.540 1239 427 2,90 3,86 82 79 1241 426 2,91 3,90 76 1216 419 2,90 3,94 70 1127 449 2,51 3,35 71 2.600 1384 478 2,90 3,86 82 79 1375 474 2,90 3,90 77 1273 505 2,52 3,32 72 kW kW dB(A) dB(A) kW kW dB(A) kW kW dB(A) kW kW dB(A) 423 145 2,92 3,72 76 74 423 146 2,90 3,75 71 417 143 2,92 3,82 64 375 148 2,53 3,37 65 462 157 2,94 3,71 77 74 456 156 2,92 3,82 71 456 157 2,90 3,79 65 418 164 2,55 3,18 65 502 170 2,95 3,75 78 75 496 170 2,92 3,79 72 498 171 2,91 3,80 65 453 181 2,50 3,22 65 535 183 2,92 3,78 78 75 532 183 2,91 3,72 72 538 184 2,92 3,80 66 498 198 2,51 3,31 67 kW °C kW °C - 443 -2,5 445 -1,5 481 -2,5 476 -2,5 524 -1,2 519 -2,8 556 -2,0 551 -2,0 610 -2,5 602 -3,4 693 -4,2 689 -4,5 774 -5,8 766 -6,1 841 -7,2 824 -7,4 887 -6,4 883 -8,5 941 -7,3 927 -9,5 1026 -7,9 1023 -7,5 1144 -9,9 1148 -8,0 1280 -6,7 1282 -7,0 1434 -5,5 1416 -7,5 2 2 DSW 400/3/50 V/Ph/Hz Data referred to the following conditions: (*) 1) (2) The programme applies to air-cooled water chillers up to 600 kW and water-cooled water chillers up to 1500 kW. Internal exchanger water 12/7°C; external air temperature 35°C Sound levels refer to units with full load under nominal test conditions. The sound pressure is measured at (3) (4) 1 m from the external surface of the unit in open field conditions. Internal exchanger water 15/10°C; glycol 30% DSW = twin-screw compressor dimensions and clearances Sizes ST/SC Length (A) ST/SC Width (B) C ST/SC Height (C) ST Weight in oper. SC Weight in oper. A2 LN Length (A) LN Width (B) LN Height (C) A LN Weight in oper. B1 EN Length (A) B B2 EN Width (B) A1 EN Height (C) CAUTION! For trouble-free operation of the unit it is essential to EN Weight in oper. maintain the clearances in green. CN Length (A) CN Width (B) CN Height (C) CN Weight in oper. leave free 4 The above data refer to standard units. (A1) (A2) (B1) (B2) mm mm mm kg kg mm mm mm kg mm mm mm kg mm mm mm kg 2.160 4754 2239 2220 3680 4080 5704 2239 2220 4337 5704 2239 2220 4337 4754 2239 2220 4008 2.180 4754 2239 2220 3781 4181 5704 2239 2220 4350 6654 2239 2220 4970 4754 2239 2220 4032 2.190 5704 2239 2220 4227 4507 5704 2239 2220 4623 6654 2239 2220 5234 4754 2239 2220 4143 2.200 5704 2239 2220 4603 4883 6654 2239 2220 5503 6654 2239 2220 5887 4754 2239 2220 4341 2.240 5704 2239 2220 4759 5039 6654 2239 2220 5543 7612 2239 2220 6349 4754 2239 2220 4708 2.280 5704 2239 2220 4780 5060 6654 2239 2220 5680 7612 2239 2220 6423 5704 2239 2220 4897 2.300 5704 2239 2370 5241 5471 6654 2239 2370 5987 9512 2239 2370 6838 6654 2239 2370 5812 2.320 5704 2239 2370 5698 5918 6654 2239 2370 6473 9512 2239 2370 7236 6654 2239 2370 6248 2.340 6654 2239 2370 5775 6175 7612 2239 2370 6844 9512 2239 2400 7408 6654 2239 2370 6259 2.360 6654 2239 2370 6010 6410 7612 2239 2370 7002 9512 2239 2400 7419 6654 2239 2370 6270 2.440 6654 2239 2370 6567 6967 9512 2239 2370 7860 11414 2239 2400 8137 6654 2239 2370 6584 2.480 7612 2239 2400 7723 8143 9512 2239 2400 8791 11414 2239 2400 9289 9512 2239 2400 8559 2.540 9512 2239 2400 8263 8683 11414 2239 2400 9330 11414 2239 2400 9562 9512 2239 2400 8831 2.600 11414 2239 2400 9115 9537 11414 2239 2400 9819 9512 2239 2400 9759 mm mm mm mm 1690 700 1100 1100 1690 700 1100 1100 1690 700 1100 1100 1690 700 1100 1100 1690 700 1100 1100 1690 700 1100 1100 1690 700 1100 1100 1690 700 1100 1100 1690 700 1100 1100 1690 700 1100 1100 1690 700 1100 1100 1690 700 1100 1100 1690 700 1100 1100 1690 700 1100 1100 87 WDAT-HT 2.180÷2.600 Water chiller Air cooled Outdoor installation Capacity from 459 to 1535 kW SCREWLINE HYDRONIC The air-cooled liquid chillers in the WDAT-HT range are the ideal solution in torrid climates with high outdoor temperatures. Equipped with high capacity twin screw compressors, R134a refrigerant and shell and tube evaporators, they are also characterised by: 4outdoor installation with operation up to 58°C 4high energy efficiency at full or partial loads: all the units have a Eurovent class A rating 4minimum environmental impact, thanks to lower CO2 emissions and the low refrigerant content achieved with dry expansion technology 4high levels of reliability and reduced maintenance costs, thanks to the heavy duty components used. External heat exchangers are also available with a specific cladding, to preserve their heat exchange properties over time 4easy installation thanks to the quick connections with the main circuit, electrical wiring enablement and complete functional testing before delivery. The on-board accessories, such as the pump assemblies and heat recovery units, lead to a further reduction in system planning and development times and costs. Eurovent Energy Efficiency Class functions and features AIR Cooling only R-134a Air cooled Outdoor inst. Refrig. R-134a Twin-screw semi. ECO BREEZE HYDRO PACK ECOBreeze HydroPack EEV Electronic Expansion Valve available configurations (1) WDAT-HT D 2.600 (2) (3) (4) ST T C (1) ENERGY RECOVERY: 4Standard 4D Partial recovery Carried out using tube bundle exchargers suited for recovering the desuperheating heat up to a maximum of 20% of the total unit heat. (2) ACOUSTIC CONFIGURATION: 4ST Standard 4SC Compressor soundproofing This set-up is obtained by inserting the compressors in a soundproofed compartment. 88 (3) ENERGY EFFICIENCY: 4T Temperate climate (Standard) (4) EXCHANGER APPROVALS: 4CE PED (European test) 4C Clivet (In-house test) accessories 4 4 ■ 4 4 4 4 4 4 4 4 4 Condenser coil in copper/aluminium with acrylic coating Condenser coil in copper/copper Condenser coil in copper/aluminium with Energy Guard DCC Aluminium treatment Spring antivibration mounts Compressor compartment and condenser coil protection grilles Set point compensation with 4-20 mA signal Set point compensation with 0-10 V signal Set point compensation with fresh air sensor Set point compensation with according to outdoor enthalpy Compressor suction shut-off valves Device for reducing consumption of the outdoor section variable speed fans (phase-cut) Hydropack with 2 pumps 4 4 4 4 4 4 ■ 4 4 4 4 ■ 4 Hydropack with 3 pumps General isolating switch Magnetothermal circuit breakers Shunt capacitors (power factor > 0,9) CAN/MODBUS serial converter kit CAN/LonWorks serial converter kit Master-slave operation Free contacts for compressor status Free contacts for compressor status and enabling Clean contacts for compressor enabling and status, local/off/BMS selector Remote control with remote microprocessor control HYDRONIC 4 Key to symbols: ■ Accessories supplied separately. technical data Sizes 4Cooling capacity Cooling capacity Total input EER EUROVENT ST Sound pressure level SC Sound pressure level Number of refrigerant circuits Number and type of compressors Power supply (1) (1) (1) (1) (2) (2) (3) kW TON kW dB(A) dB(A) V/Ph/Hz 2.180 2.200 2.220 2.240 2.280 2.320 2.360 2.420 2.450 2.480 2.510 2.540 2.570 2.600 413 471 534 592 665 782 871 925 995 1075 1150 1202 1281 1349 118 135 153 169 190 223 249 264 284 307 329 343 366 385 164 188 212 235 263 310 345 367 394 428 457 478 509 534 2,52 2,51 2,52 2,52 2,53 2,52 2,52 2,52 2,53 2,51 2,52 2,51 2,52 2,53 80 81 81 81 82 82 83 83 84 84 84 85 85 85 77 78 79 79 79 79 80 80 81 81 81 82 82 82 2 2 DSW 400/3/50 Data referred to the following conditions: (1) (2) Internal exchanger water 12/7°C; ambient temperature 46°C Sound levels refer to units with full load under nominal test conditions. The sound pressure is measured at 1 m from the external surface of the unit in open field conditions. DSW = twin-screw compressor (3) dimensions and clearances leave free C A2 A Sizes Length (A) Width (B) Height (C) (A1) 4 (A2) (B1) (B2) mm mm mm mm mm mm mm 2.180 5700 2233 2250 1690 700 1100 1100 2.200 5700 2233 2250 1690 700 1100 1100 2.220 5700 2233 2250 1690 700 1100 1100 2.240 6650 2233 2250 1690 700 1100 1100 2.280 6650 2233 2250 1690 700 1100 1100 2.320 7600 2233 2250 1690 700 1100 1100 2.360 9500 2233 2400 1690 700 1100 1100 2.420 9500 2233 2400 1690 700 1100 1100 2.450 10450 2233 2400 1690 700 1100 1100 2.480 11400 2233 2400 1690 700 1100 1100 2.510 11400 2233 2400 1690 700 1100 1100 2.540 11400 2233 2400 1690 700 1100 1100 2.570 11900 2233 2500 1690 700 1100 1100 2.600 11900 2233 2500 1690 700 1100 1100 The above data refer to standard units. B1 B B2 CAUTION! A1 For trouble-free operation of the unit it is essential to maintain the clearances in green. 89 WSA-EE WSN-EE 17÷91 Water chiller ELFOENERGY SMALL 4WSA-EE: cooling only 4WSN-EE: reversible heat pump HYDRONIC Air cooled Indoor installation Capacity from 4,47 to 22,6 kW The liquid chillers and heat pumps of the ELFOEnergy WSA-EE and WSN-EE series are units designed for indoor installation and best energy efficiency in relation to their reduced size. The ELFOEnergy series has been the turning point in the evolution of chillers. Every unit has been conceived and made by applying state-of-the-art technology, emphasising the qualities of EFFICIENCY, SELF-ADAPTATION and EASY INSTALLATION that distinguish this product. Thanks to its constructional and electronic peculiarities, ELFOEnergy permits: 4adaptability of operating parameters to the load conditions of the connected system, thereby optimising consumption, efficiency and working life of the parts; 4easy, quick installation thanks to the standard hydronic group and the factory test carried out prior to dispatch. 4use of a centrifugal fan, which allows the air from the condensing section to be ducted. functions and features AIR Cooling only (WSA-EE) Heating-Cooling (WSN-EE) R-407C Air cooled Indoor inst. Refrig. R-407C Herm. Rotary (sizes 17÷25) Herm. Scroll (sizes 31÷91) ELFOControl Ice protection system (WSN-EE only) Vary Flow (sizes 17÷31) available configurations (1) WSN-EE S 17 (2) (3) CE T (1) VERSION: 4S Standard 4B Low water temperature This version allows unit operation within the water and glycol mixing temperature range between +5°C and -8°C inclusive. Two versions are available - Unit for low temperatures only - Unit with double operating set-point 90 (2) EXCHANGER APPROVALS: 4CE PED (European test) (3) ENERGY EFFICIENCY: 4T Temperate climate accessories ■ 4 4 4 4 ■ 4 4 ■ 4 ■ 4 ■ 4 Rubber antivibration mounts Condenser coil in copper/aluminium with acrylic coating Condenser coil in copper/aluminium with Energy Guard DCC Aluminium treatment Copper/copper condenser coil Serial communication module (MODBUS) Device for operation with low external air temperature with variable fan speed through inverter (sizes 71÷91) Steel mesh filter on water side Remote keyboard for user, to control the unit main functions Service keypad (cable from 1,5 metres) Phase monitor Set point compensation with according to outdoor enthalpy ■ 4 Double temperature control kit, set point compensation 4-20 mA, 3-way valve 4 Supply voltage 230/1/50 (for sizes 31-41) 4 Supply voltage 400/3/50+N (for sizes 17÷25) 4 Unit without hydronic group WSA-EE only: ■ 4 Device for operation with low external air temperature with variable fan speed (sizes 17÷61) ■ 4 Set point compensation with fresh air sensor ■ 4 ■ 4 HYDRONIC Key to symbols: ■ Accessories supplied separately. technical data Sizes WSA-EE A35/W7 4Cooling capacity Total input EER EUROVENT ESEER Pump working head WSN-EE A35/W7 4Cooling capacity Total input EER EUROVENT ESEER A7/W45 4Heating capacity Total input COP EUROVENT A2/W45 4Heating capacity Total input COP EUROVENT A-5/W45 4Heating capacity Total input COP EUROVENT Pump working head Air side available static pressure Minimum external air temperature Maximum water temperature Water flow rate Sound pressure level Power supply (1) (2) (4) (5) (6) (1) (2) (4) (5) (1) (2) (3) (1) (2) (3) (1) (2) (3) (6) (6) (6) (7) 17 21 25 31 41 51 61 71 81 91 kW kW kPa 4,47 1,76 2,54 2,84 52 5,37 2,18 2,46 2,88 42 7,14 2,91 2,45 2,70 44 8,50 3,39 2,51 2,88 32 10,7 4,55 2,35 2,62 149 12,9 5,23 2,47 2,75 129 14,9 6,12 2,43 2,77 123 17,0 6,76 2,51 2,86 105 18,8 7,73 2,43 2,77 114 22,6 8,91 2,54 2,86 87 kW kW - 4,37 1,77 2,47 2,76 5,24 2,28 2,30 2,74 7,13 2,93 2,43 2,68 8,39 3,38 2,48 2,86 10,6 4,47 2,37 2,63 12,5 5,25 2,38 2,67 14,5 6,16 2,37 2,69 17,0 6,67 2,55 2,89 18,7 7,57 2,47 2,78 22,4 8,85 2,53 2,87 kW kW - 4,79 1,88 2,55 5,74 2,35 2,44 7,67 3,00 2,56 9,16 3,67 2,50 11,4 4,82 2,37 13,6 5,73 2,37 15,8 6,41 2,46 18,8 7,56 2,49 20,6 8,06 2,56 24,7 9,76 2,53 kW kW - 4,22 1,79 2,36 5,08 2,28 2,23 6,77 2,90 2,33 8,17 3,64 2,24 10,1 4,78 2,11 11,8 5,47 2,16 13,8 6,29 2,19 16,4 7,41 2,21 18,0 7,91 2,28 21,9 9,56 2,29 kW kW kPa Pa °C °C I/s dB(A) V/Ph/Hz 3,20 1,67 1,92 53 60 -10 53 0,21 39 3,91 2,20 1,78 44 60 -10 52,5 0,25 40 230/1/50 5,30 2,74 1,94 44 60 -10 53,5 0,34 42 6,57 3,72 1,77 34 60 -10 52 0,40 43 7,81 4,72 1,66 150 100 -10 52 0,51 47 8,90 5,39 1,65 132 100 -10 51,5 0,60 48 10,5 12,4 6,20 7,26 1,69 1,70 126 105 100 100 -10 -10 52 50,5 0,71 0,81 48 51 400/3/50+N 13,5 7,80 1,73 114 100 -10 53 0,89 52 17,1 9,33 1,83 89 100 -10 51,5 1,07 53 Data referred to the following conditions: (1) (2) (3) A35 / W7 internal exchanger water 12/7°C; external air temperature 35°C A7 / W45 internal exchanger water 40/45°C; external air temperature 7°C D.B./ 6°C W.B. A2 / W45 internal exchanger water 40/45°C; external air temperature 2°C D.B./ 1,1°C W.B. A-5 / W45 internal exchanger water 40/45°C; external air temperature -5°C D.B./ -5,4°C W.B. The total power input is the total power absorbed by the compressors + fans - the power absorbed by the fan to supply the remaining available static pressure to the system + the power absorbed by the auxiliary circuit EUROVENT COP: coefficient of performance in heating mode. Relationship between heating capacity output and power input according to EUROVENT. The power input is the total power absorbed by the compressor + fan + auxiliary circuit + defrost cycles. (4) (5) (6) (7) EUROVENT EER calculated as the relationship between the cooling capacity and the total power input. ESEER coefficient of seasonal performance in cooling mode calculated according to Eurovent. Outlet water 7°C. Water flow and available static pressure in winter operating conditions A7/W35: water at the internal heat exchanger 30/35°C; outdoor air temperature 7°C D.B. / 6°C W.B. Sound levels refer to units with full load under nominal test conditions. The sound pressure is measured at 10 m from the external surface of the unit in open field conditions. dimensions and clearances C A B B2 CAUTION! A1 For trouble-free operation of the unit it is essential to maintain the clearances in green. Sizes WSA-EE Length (A) Width (B) Height (C) 4(A1) (B2) Weight in oper. WSN-EE Length (A) Width (B) Height (C) 4(A1) (B2) Weight in oper. 17 21 25 31 41 51 61 71 81 91 mm mm mm mm mm kg 838 561 649 500 200 83 838 561 649 500 200 89 982 647 648 500 200 121 982 647 648 500 200 130 1206 724 721 500 200 168 1206 724 721 500 200 176 1206 724 721 500 200 180 1516 760 1045 500 200 256 1516 760 1045 500 200 320 1516 760 1045 500 200 329 mm mm mm mm mm kg 838 560 649 500 150 84 838 560 649 500 150 90 982 649 648 500 200 122 982 649 648 500 200 131 1206 724 721 500 200 169 1206 724 721 500 200 177 1206 724 721 500 200 181 1516 760 1043 500 200 260 1516 760 1043 500 200 323 1516 760 1043 500 200 332 The above data refer to standard units. 91 WSA-XEE WSN-XEE 122÷402 Water chiller ELFOENERGY DUCT MEDIUM 4WSA-XEE: cooling only 4WSN-XEE: heat pump Air cooled Indoor installation Capacity from 36 to 101 kW NEW HYDRONIC Available from the 2nd semester 2011 The chillers and heat pumps of WSA-XEE and WSN-XEE series are indoor units with ducted condensation. Thanks to his special design ELFOEnergy Duct Medium main features are: 4Versatility: different combinations of inlet and outlet plug fans enable to connect easily the unit to the air ducts and to have high available head; 4High energy efficiency: ELFOEnergy Duct Medium besides being in Eurovent efficiency class A at full load grants high seasonal power efficiency thanks to the innovative cooling circuit optimized for partial load operation and the DST (Dynamic Supply Temperature) return control logic; 4Easy installation: the units are very compact and are supplied with high efficiency pumps on board; therefore the available space for other purposes is increased and the installations costs are reduced. Eurovent Energy Efficiency Class functions and features AIR Cooling only (WSA-XEE) Heating-Cooling (WSN-XEE) EEV R-410A Air cooled Refrig. R-410A Indoor inst. Herm. Scroll ECO BREEZE Electronic Expansion Valve ECOBreeze available configurations (1) WSA-XEE (1) 142 (2) (3) (4) (5) (6) (7) (8) (9) 400T 1PUHE - - - - - MO LOW TEMPERATURE: 4S Standard 4B Low water temperature This version allows unit operation within the water and glycol mixing temperature range between +4°C and -7°C inclusive. 4DSPB Double set-point for water low temperature (Brine) (5) (2) SUPPLY VOLTAGE: 4400T Supply voltage 400/3/50 CONDENSER COIL: 4CCS Standard condenser coil 4CCCA Condenser coil in copper/aluminium with acrylic coating 4CCCA1 Condenser coil in copper/aluminium with Energy Guard DCC Aluminium treatment (6) (3) HYDRONIC GROUP USER SIDE: 41PUHEInverter pump for primary circuit (standard) 41PUS Standard pump 41PUM Single pump with larger discharge head 42PUS Standard double pump 42PUM Double pump with larger discharge head 4Not required SOFT STARTER: 4Not required (standard) 4SFSTR Device for inrush current reduction for 400/3/50 (7) SHUNT CAPACITORS (COSFI > 0,9): 4Not required (standard) 4PFCP Shunt capacitors (cosfi > 0,9) (8) REDUCED OUT. SECT. FAN CONSUMPTION: 4CREFB Device for the reduction of ECOBreeze type outdoor section fan consumption (Standard) 4Not required (9) AIR SUPPLY: 4MO Horizontal air supply (standard) 4M5 Upward air supply (4) 92 S ENERGY RECOVERY: 4Not required 4D Partial recovery Carried out using braze-welded plate-type exchangers suited for recovering the desuperheating heat up to a maximum of 25% of the total unit heat. 4R Total recovery Carried out using braze-welded plate-type exchangers suited for 100% recovery of the total unit heat. accessories ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 Rubber antivibration mounts Serial communication module to Serial communication module to Serial communication module to Steel mesh filter on water side group” configuration) ■ 4 supervisor (MODBUS) supervisor (BACnet) supervisor (LonWorks) (when unit is in “without hydronic ■ 4 ■ 4 High and low pressure gauges Remote interface kit to microprocessor unit Phase monitor to check the presence and correct sequence of the power supply phases Key to symbols: HYDRONIC ■ Accessories supplied separately. technical data Sizes Application with terminal units WSA-XEE 4Cooling capacity Total input EER EUROVENT ESEER EUROVENT Seasonal efficiency DST Pump working head WSN-XEE 4Cooling capacity Total input EER EUROVENT 4Heating capacity Total input COP EUROVENT Pump working head Application with radiant panels WSN-XEE 4Heating capacity Total input COP (EN:14511:2008) Pump working head Number of refrigerant circuits Number and type of compressors Sound pressure level Power supply 122 162 182 222 262 302 352 402 41,8 14,3 2,92 4,07 4,30 55 49,3 17,0 2,91 4,15 4,41 45 58,3 20,7 2,81 4,04 4,32 43 67,8 23,7 2,86 4,01 4,25 39 78,3 27,2 2,88 4,02 4,27 52 88,3 31,2 2,83 4,07 4,31 44 101 36,5 2,76 3,97 4,18 44 (1) (1)(2) (1) (1) (7) (1) kW kW kPa 36,0 12,2 2,94 3,90 4,16 59 (1) (1)(2) (1) (3) (2)(3) (3) (1) kW kW kW kW kPa 33,2 12,9 2,58 41,3 12,7 3,25 75 38,2 15,1 2,53 47,9 14,7 3,26 73 43,4 18,7 2,32 55,9 17,7 3,16 68 52,1 22,1 2,36 65,1 20,5 3,18 63 61,9 24,6 2,51 77,3 23,5 3,29 51 71,4 28,3 2,52 88,3 27,0 3,27 65 79,2 33,7 2,35 97,9 30,6 3,20 63 - (4) (4)(5) (4) (4) kW kW kPa dB(A) V/Ph/Hz 42,2 10,3 4,09 46 49,0 11,9 4,12 42 57,1 14,4 3,96 32 66,5 16,9 3,94 34 79,4 19,6 4,05 26 90,3 22,4 4,03 49 100 25,2 3,96 46 - 67 67 68 (6) 1 2 SCROLL 60 61 64 65 66 400/3/50 Data referred to the following conditions: PRELIMINARY DATA (1) Internal exchanger water 12/7°C; air entering external exchanger 35°C (2) Total input is obtained from the compressor input + fan input - the proportional part of the fan to supply the available head to installation input + auxiliary circuit input. (3) Ambient temperature 7°C D.B./ 6°C W.B.; internal exchanger water outlet temperature 45°C (4) Fresh air temperature 7°C D.B./ 6°C W.B.; internal exchanger water temperature 30/35°C (5) The total absorbed power is calculated adding the compressors power input + the fan power input - the (6) (7) proportional part of the fan to supply the available head to installation input + the power absorbed by the pump - the proportional part of the pump to supply the available head to installation input + the power absorbed by the auxiliary circuit. Sound levels refer to units with full load under nominal test conditions. The sound pressure is measured at 1 m from the external surface of the unit in open field conditions. DST = Dynamic Supply Temperature: return control logic. functional spaces dimensions and clearances (*) C A1 A (*) Optional CAUTION! A2 B1 B B2 Sizes WSA-XEE Length (A) Width (B) Height (C) 4(A1) (A2) (B1) (B2) WSN-XEE Length (A) Width (B) Height (C) 4(A1) (A2) (B1) (B2) 122 162 182 222 262 302 352 402 mm mm mm mm mm mm mm 1450 780 1997 1000 500 100 1300 1450 780 1997 1000 500 100 1300 1850 780 1997 1000 500 100 1300 1850 780 1997 1000 500 100 1300 2250 780 1997 1000 500 100 1300 2650 780 1997 1000 500 100 1300 2650 780 1997 1000 500 100 1300 2650 780 1997 1000 500 100 1300 mm mm mm mm mm mm mm 1450 780 1997 1000 500 100 1300 1850 780 1997 1000 500 100 1300 1850 780 1997 1000 500 100 1300 2250 780 1997 1000 500 100 1300 2650 780 1997 1000 500 100 1300 2650 780 1997 1000 500 100 1300 2650 780 1997 1000 500 100 1300 - The above data refer to standard units. For trouble-free operation of the unit it is essential to maintain the clearances in green. 93 WRA WRN 404÷604 Water chiller 4WRA: cooling only 4WRN: reversible heat pump HYDRONIC Air cooled Indoor installation Capacity from 100 to 144 kW The liquid chillers and heat pumps of the WRA and WRN series are units designed for indoor installation and best energy efficiency in relation to their reduced size. Use of low-rev centrifugal fans and special thermal and acoustic insulation of the cabinet have resulted in highly reduced noise levels. The head pressures available with centrifugal fans enable wide ducting for air return and cooled air discharge to be installed. functions and features AIR Cooling only (WRA) Heating-Cooling (WRN) R-407C Air cooled Indoor inst. Refrig. R-407C Herm. Scroll Ice protection system available configurations WRA (1) (2) D B 404 (3) (4) (5) ST T C (1) ENERGY RECOVERY: 4Not required 4D Partial recovery Carried out using braze-welded plate-type exchangers suited for recovering the desuperheating heat up to a maximum of 25% of the total unit heat. (2) LOW TEMPERATURE: 4Not required 4B Low water temperature This version allows unit operation within the water and glycol mixing temperature range between +5°C and -7°C inclusive. Two versions are available: - Unit for low temperatures only - Unit with double operating set-point The possibility of reducing the cooling capacity depends on the working temperature. 94 (3) ACOUSTIC CONFIGURATION: 4ST Standard (4) ENERGY EFFICIENCY: 4T Temperate climate (Standard) (5) EXCHANGER APPROVALS: 4CE PED (European test) 4C Clivet (In-house test) accessories 4 4 ■ 4 ■ 4 4 ■ 4 4 4 4 4 4 4 Condenser coil in copper/aluminium with acrylic coating Condenser coil in copper/aluminium with Energy Guard DCC Aluminium treatment Copper/copper condenser coil Spring antivibration mounts Rubber antivibration mounts High and low pressure gauges Steel mesh filter on water side Uprated electric fan motor 4/8-pole electric fan motor Horizontal air supply Upward air supply Magnetothermal circuit breakers Compressor and fan thermal cutouts Phase monitor Daily and weekly programming clock 4 Shunt capacitors (power factor > 0,9) 4 Serial communication module PC/BMS MODBUS for 1 unit (Master) ■ 4 Remote control with remote microprocessor control WRA only: 4 Anti-ice electric heater to protect the internal exchanger WRN only: 4 Condensate collecting tray with electric heater 4 4 HYDRONIC 4 Key to symbols: ■ Accessories supplied separately. technical data Sizes WRA 4Cooling capacity Total input Total EER at 100% WRN 4Cooling capacity Total input Total EER at 100% 4Heating capacity Total input Max. working static pressure Number of refrigerant circuits Number and type of compressors Sound pressure level Power supply 404 464 524 564 604 (1) kW kW - 100 45,5 2,20 111 50,1 2,22 121 56,7 2,14 137 60,9 2,25 144 68,2 2,11 (1) kW kW kW kW Pa dB(A) V/Ph/Hz 100 43,7 2,28 112 42,7 90 109 49,4 2,21 124 48,2 90 132 62,1 2,13 152 60,6 120 140 68,0 2,07 163 66,3 90 61 61 118 55,5 2,13 137 54,1 90 2 4 SCROLL 61 400/3/50 63 64 (2) (3) (4) Data referred to the following conditions: (1) (2) (3) Internal exchanger water = 12/7°C; external air temperature 35°C; External exchanger water = 40/45°C; ambient temperature = 7°C (R.H. = 85%) RCP = reciprocating (4) Sound levels refer to units with full load under nominal test conditions. The sound pressure is measured at 1 m from the external surface of the unit in open field conditions. dimensions and clearances Sizes Length (A) Width (B) Height (C) 4(A1) (A2) (B1) (B2) Weight in oper. C B1 CAUTION! A2 B mm mm mm mm mm mm mm kg 404 3308 1155 2275 500 500 70 1300 1530 464 3308 1155 2275 500 500 70 1300 1590 524 3308 1155 2275 500 500 70 1300 1620 564 3308 1155 2275 500 500 70 1300 1710 604 3308 1155 2275 500 500 70 1300 1740 The above data refer to standard units. A B2 A1 For trouble-free operation of the unit it is essential to maintain the clearances in green. 95 WSA-SC 65D÷100D Water chiller Air cooled Indoor installation Capacity from 173 to 257 kW SPINCHILLER HYDRONIC The SPINchiller series presents a new concept of chiller. The WSA-SC units are designed for indoor installation with ducted discharge for chilled water solutions. These units offer: 4EFFICIENCY that increases as the heating load decreases, while guaranteeing maximum requested load when necessary. SPINchiller always ensures maximum comfort with very high efficiency and consequently considerable energy savings; 4simple unit-system combination, since these units are SELF-ADAPTING to the characteristics of the actual system, thereby avoiding delicate, time-consuming calibrations. Easy connection to the service system plus a simple control system and easy maintenance of all the most sensitive parts drastically reduce work requiring specialised personnel with consequent reduction in installation costs; 4The particular abundance of optional accessories allows customisation of the unit, also for special requirements both in the civil and technological air-conditioning sphere. In particular the optional for the HydroPack water circulating unit, consistent with the concept of modularity, has several pumps in parallel (up to 3), to monitor the system load variations better and to regulate the water flow in the critical system starting (or restarting) stages so that outside servicing is avoided. The innovative and hi-tech features of SPINchiller give this series a much higher quality than can generally be found on the market today. functions and features AIR Cooling only Air cooled Indoor inst. EEV HYDRO PACK R-407C Refrig. R-407C Herm. Scroll HydroPack Electronic Expansion Valve available configurations WSA-SC (1) (2) R B 65D (3) (4) (5) SC T C (1) ENERGY RECOVERY: 4Not required 4D Partial recovery Carried out using braze-welded plate-type exchangers suited for recovering the desuperheating heat up to a maximum of 20% of the total unit heat. 4R Total recovery Carried out using braze-welded plate-type exchangers suited for 100% recovery of condensation heat for producing hot water. (2) LOW TEMPERATURE: 4Not required 4B Low water temperature This version allows unit operation within the water and glycol mixing temperature range between +5°C and -7°C inclusive. Two versions are available: - Unit for low temperatures only - Unit with double operating set-point The possibility of reducing the cooling capacity depends on the working temperature. 96 (3) ACOUSTIC CONFIGURATION: 4SC Compressor soundproofing (Standard) (4) ENERGY EFFICIENCY: 4T Temperate climate (Standard) (5) EXCHANGER APPROVALS: 4CE PED (European test) 4C Clivet (In-house test) accessories 4 ■ 4 4 4 4 4 4 4 4 ■ 4 4 4 Condenser coil in copper/aluminium with acrylic coating Condenser coil in copper/aluminium with Energy Guard DCC Aluminium treatment Spring antivibration mounts Shut-off valve on compressor supply and return High and low pressure gauges HydroPack with 2 pumps HydroPack with 2 pumps + 1 in stand-by HydroPack with 3 pumps HydroPack with 3 pumps + 1 spare onboard User side anti-ice electric heaters for hydronic group Steel mesh filter on water side Set point compensation with 4-20 mA signal Set point compensation with fresh air sensor 4 4 4 4 4 4 4 4 4 4 ■ 4 4 ■ 4 Set point compensation with according to outdoor enthalpy Uprated electric fan motor 4/8-pole electric fan motor Kit for low external temperatures with variable fan speed with inverter Horizontal air supply Upward air supply Phase monitor Shunt capacitors (power factor > 0,9) CAN/MODBUS serial converter kit CAN/LonWorks serial converter kit Master-slave operation Free contacts for compressor status Remote control with remote microprocessor control HYDRONIC 4 Key to symbols: ■ Accessories supplied separately. technical data Sizes 4Cooling capacity Total input EER EUROVENT ESEER Max. working static pressure Number of refrigerant circuits Number and type of compressors Sound pressure level Power supply (1) (2) 65D 173 66,9 2,55 2,80 90 kW kW Pa dB(A) V/Ph/Hz 70D 182 71,1 2,54 2,82 50 75C 200 75,7 2,63 3,90 50 1 3 SCROLL 73 2 4 SCROLL 72 73 75D 198 79,0 2,50 2,77 60 80D 212 82,0 2,53 2,86 90 2 4 SCROLL 74 74 400/3/50 90C 237 94,4 2,46 3,85 90 1 3 SCROLL 74 90D 231 92,0 2,44 2,67 120 100D 257 102 2,41 2,67 120 2 4 SCROLL 75 76 Data referred to the following conditions: (1) (2) Internal exchanger water = 12/7°C; external air temperature 35°C; Sound levels refer to units with full load under nominal test conditions. The sound pressure is measured at 1 m from the external surface of the unit in open field conditions. dimensions and clearances (* ) C A2 B1 A B B2 Sizes Length (A) Width (B) Height (C) 4(A1) (A2) (B1) (B2) Weight in oper. mm mm mm mm mm mm mm kg 65D 4400 1140 2270 900 900 1300 70D 4400 1140 2270 900 900 1300 75C 4400 1140 2270 900 900 1300 75D 4400 1140 2270 900 900 1300 2135 2312 2118 2176 80D 4400 1140 2270 900 900 1300 90C 4400 1140 2270 900 900 1300 90D 4400 1140 2270 900 900 1300 100D 4400 1140 2270 900 900 1300 2258 2385 2437 2474 (**) The above data refer to standard units. (**) Space depending on the type of installation. A1 (*) OPTIONAL CAUTION! For trouble-free operation of the unit it is essential to maintain the clearances in green. 97 WSHF-XSC 65D÷180F Monobloc unit SPINSAVER 44 Simultaneous and independent heating and cooling Water cooled Indoor installation Capacity from 173 to 500 kW HYDRONIC SPINSAVER is the high efficiency monobloc unit for centralised systems, able to provide both simultaneous and independent heating and cooling. SPINchiller technology offers high seasonal efficiency, using several Scroll compressors per circuit and working together with the innovative built-in automatic hydraulic switch system in SPINSAVER. In fact, hot and cold fluids are produced simultaneously in all load conditions with maximum energy recovery. The source is therefore only activated to exchange any excess energy, with considerable savings in terms of extraction circuit pumping energy. As a result, total primary energy savings can reach up to 50%. Thanks to its effective production combination, SPINSAVER is therefore the ideal solution for civil and industrial applications with centralised “four-pipe” type installations. PATENT PENDING functions and features H2O Heating-Cooling EEV R-410A Water cooled Indoor inst. Outdoor inst. (Optional) Refrig. R-410A Herm. Scroll available configurations (1) WSHF-XSC - 150F (2) (3) EN C (1) SYSTEM TYPE: 4System with terminal units 4PR System with radiant panels, induction terminal units or chilled beams (2) ACOUSTIC CONFIGURATION: 4ST Standard 4EN Super Silenced This set-up is obtained by inserting the compressors in a soundproofed compartment. (3) EXCHANGER APPROVALS: 4CE PED (European test) 4C Clivet (In-house test) 98 Electronic Expansion Valve accessories ■ 4 4 4 4 ■ 4 4 4 4 Rubber antivibration mounts kit Outdoor installation (only for acoustic configuration EN) Shut-off valve on compressor return High and low pressure gauges Steel mesh mechanical filter. To be mounted at the exchanger inlet Phase monitor Shunt capacitors (power factor > 0,9) Soft Start 4 4 4 4 ■ 4 MODBUS serial converter kit LonWorks serial converter kit BACnet serial converter kit Free contacts for compressor status Remote control microprocessor unit for repeat commands Key to symbols: HYDRONIC ■ Accessories supplied separately. technical data Sizes 65D 70D 75D 80D 85D 90D 100D 110D 115D 120D 135E 150F 165F 180F COOLING 100% - HEATING 100% 4 Cooling capacity 4 Heating capacity Total input Overall efficiency (1) (1) kW kW kW - 173 224 51,4 7,73 182 237 55,2 7,59 199 257 58,4 7,80 208 269 61,8 7,72 224 289 65,1 7,88 254 327 73,4 7,91 276 356 80,1 7,89 297 383 86,8 7,83 314 407 93,3 7,72 330 428 98,4 7,70 360 466 107 7,74 391 506 116 7,76 444 574 130 7,83 500 646 148 7,74 (2) kW kW - 212 32,6 6,50 227 34,8 6,51 243 37,9 6,41 255 39,9 6,38 272 43,6 6,25 311 47,4 6,56 341 52,2 6,54 364 55,7 6,54 385 59,6 6,46 404 62,4 6,48 443 68,2 6,50 480 74,6 6,46 539 83,6 6,45 608 94,4 6,44 (3) kW kW dB(A) dB(A) V/Ph/Hz 224 51,4 4,36 237 55,2 4,29 257 58,4 4,40 269 61,8 4,36 289 65,1 4,43 327 73,4 4,45 356 80,1 4,44 383 86,8 4,41 407 93,3 4,36 428 98,4 4,35 466 107 4,37 506 116 4,38 574 130 4,41 646 148 4,37 76 68 76 68 5 SCROLL 76 68 76 68 COOLING 100% - HEATING 0% 4 Cooling capacity Total input EER at full load COOLING 0% - HEATING 100% 4 Heating capacity Total input COP at full load Number of refrigerant circuits Number and type of compressors ST Sound pressure level EN Sound pressure level Power supply (4) (4) 2 73 64 74 64 74 65 74 65 4 SCROLL 74 74 66 66 76 76 67 68 400/3/50 6 SCROLL 77 77 68 69 Data referred to the following conditions: (1) (2) (3) Cooling circuit water 7/12°C; heating circuit water 45/40°C; Cooling circuit water 7/12°C; source circuit water 15/25°C; Heating circuit water 40/45°C; source circuit water 12/7°C; (4) Sound levels refer to units with full load under nominal test conditions. The sound pressure is measured at 1 m from the external surface of the unit in open field conditions. Heating circuit water 30/35°C; Cooling circuit water 7/12°C dimensions and clearances Sizes Length (A) Width (B) Height (C) 4(A1) (A2) (B1) (B2) C A1 65D 4266 850 2000 1000 1500 1000 700 70D 4266 850 2000 1000 1500 1000 700 75D 4266 850 2000 1000 1500 1000 700 80D 4266 850 2000 1000 1500 1000 700 85D 4266 850 2000 1000 1500 1000 700 90D 4266 850 2000 1000 1500 1000 700 100D 4266 850 2000 1000 1500 1000 700 110D 4266 850 2000 1000 1500 1000 700 115D 4266 850 2000 1000 1500 1000 700 120D 4266 850 2000 1000 1500 1000 700 135E 4723 850 2000 1000 1500 1000 700 150F 4723 850 2000 1000 1500 1000 700 165F 4723 850 2000 1000 1500 1000 700 180F 4723 850 2000 1000 1500 1000 700 The above data refer to standard units. A A2 CAUTION! mm mm mm mm mm mm mm B B2 B1 For trouble-free operation of the unit it is essential to maintain the clearances in green. 99 WRH WRHN 102÷422 Water chiller 4WRH: cooling only 4WRHN: reversible heat pump HYDRONIC Water cooled Indoor installation Capacity from 27,1 to 144 kW The water-water chillers and heat pumps with hermetic compressors in the WRH and WRHN series are water-cooled units designed for indoor installation. They may be used in modern civil and industrial service systems because of their limited overall size and low noise levels. They only require water and electrical connections, since the units are fully assembled and tested in the factory. The WRHN units are fitted with reversing valve on the refrigerant circuit, thereby considerably reducing installation and maintenance costs. functions and features H2O Cooling only (WRH) Heating-Cooling (WRHN) R-407C Water cooled Indoor inst. Refrig. R-407C Herm. Scroll Water circuit reversal (WRH) available configurations (1) WRH-2 S 102 (2) (3) (4) CE B S (1) VERSION: 4S Standard (2) EXCHANGER APPROVALS: 4CE PED (European test) (3) LOW TEMPERATURE: 4Not required 4B Low temperature This version allows unit operation within the water and glycol mixing temperature range between +5°C and -7°C inclusive. 100 (4) OPERATION (WRH only): 4H Reversibility on water circuit Version that allows water-water heat pump operation with reversibility on the water circuit. It is suited to civil and industrial hot water production. The external exchangers are clad with closed-cell insulating material. accessories ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 Pressure-controlled valve Remote control with remote microprocessor control 4 Supply voltage 400/3/50 without neutral WRHN 292÷422 only: 4 Low water temperature source side 4 Device for inrush current reduction for 400/3/50 units 4 Shunt capacitors (power factor > 0,9) 4 Free Contacts External Signal Manifold for unit with double exchanger Serial communication module PC/BMS MODBUS for 1 unit (Master) Serial communication module PC/BMS MODBUS from 2 to 254 units (Slave) Steel mesh filter on water side Daily and weekly programming clock Phase monitor ■ 4 ■ 4 Key to symbols: HYDRONIC ■ Accessories supplied separately. technical data Sizes WRH 4 Cooling capacity Total input Total EER at 100% ESEER 4 Heating capacity WRHH WRHN 4 Cooling capacity Total input Total EER at 100% ESEER 4Heating capacity Total input COP Water flow rate (External Exchanger) Number of refrigerant circuits Number and type of compressors Sound pressure level Power supply (1) kW (1) kW (2) kW kW kW kW kW l/s dB(A) V/Ph/Hz (1) (1) (4) (1) (3) 102 142 162 182 202 222 242 292 322 362 422 27,1 6,97 3,89 4,55 32,4 36,5 8,86 4,12 4,45 43,6 40,3 10,7 3,77 4,28 49,2 47,5 12,9 3,68 4,11 58,1 55,9 14,4 3,88 4,37 68,0 61,8 16,3 3,79 4,29 75,4 68,4 17,9 3,82 4,35 83,2 89,4 20,1 4,26 5,06 106 104 25,2 4,13 4,54 125 119 28,8 4,13 4,37 143 144 36,0 4,00 4,67 176 27,2 7,14 3,81 4,72 32,1 9,40 3,41 1,3 36,2 9,3 3,88 4,82 42,7 12,3 3,47 1,7 39,4 11,0 3,58 4,23 47,3 14,4 3,28 1,9 46,8 13,7 3,42 3,90 57,2 18,4 3,11 2,2 54,8 15,6 3,51 4,09 66,4 20,7 3,21 2,6 67,3 19,3 3,49 4,04 81,5 25,4 3,21 3,2 86,5 22,9 3,77 4,55 102 27,9 3,65 4,1 102 27,1 3,76 4,09 123 32,8 3,75 4,9 118 31,2 3,78 3,93 141 37,6 3,75 5,6 144 38,4 3,75 4,20 173 46,2 3,74 6,9 53 53 62 62 63 61,1 17,4 3,51 4,09 74,0 23,1 3,20 2,9 2 2 SCROLL 64 400/3/50 65 66 66 66 66 Data referred to the following conditions: (1) (2) Internal exchanger water = 12/7 °C; water temperature at external exchanger outlet = 30/35°C Water at external exchanger inlet = 10 °C; internal exchanger waterr = 42/50 °C (sizes 102÷242); internal exchanger water = 45/50 °C (sizes 292÷422) (3) (4) Sound levels refer to units with full load under nominal test conditions. The sound pressure is measured at 1 m from the external surface of the unit in open field conditions. Water at external exchanger inlet = 10 °C; water temperature at internal exchanger outlet 45°C dimensions and clearances C mod on B2 A1 A CAUTION! B A2 Sizes Length (A) Width (B) Height (C) 4(A1) (A2) (B1) (B2) WRH Weight in oper. WRHN Weight in oper. mm mm mm mm mm mm mm 102 802 602 790 300 300 500 300 142 802 602 790 300 300 500 300 162 802 602 915 300 300 500 300 182 802 602 915 300 300 500 300 202 802 602 915 300 300 500 300 222 802 602 915 300 300 500 300 242 802 602 915 300 300 500 300 292 1062 580 1538 300 300 500 300 322 1062 580 1538 300 300 500 300 362 1062 580 1538 300 300 500 300 422 1062 580 1538 300 300 500 300 kg 177 197 245 247 257 263 268 447 487 517 577 kg 187 207 255 257 269 275 280 470 510 540 600 The above data refer to standard units. B1 For trouble-free operation of the unit it is essential to maintain the clearances in green. 101 WSH-XSC 65D÷180F Water chiller Water cooled Indoor/outdoor installation Capacity from 195 to 560 kW SPINCHILLER The WSH-XSC units belong to the SPINchiller family and therefore feature high energy efficiency, self-adaptation and reliability. HYDRONIC 4Compactness: when designing the unit special attention was paid to reducing the dimensions of the front as much as possible. The width in the units up to 560 kW capacity has been reduced to just 85 cm so that they can pass through normal doorways. 4Special attention has been paid to making connection to the service system easy so that work requiring specialised personnel is drastically reduced thereby allowing installation costs to be cut considerably. This same policy ensured that attention was paid to easiness of controls and maintenance on all the most sensitive parts. 4EFFICIENCY that increases as the heating load decreases, while guaranteeing maximum requested load when necessary. SPINchiller always ensures maximum comfort with very high efficiency and consequently considerable energy savings; 4The particular abundance of optional accessories allows customisation of the unit, also for special requirements both in the civil and technological air-conditioning sphere. In particular the optional for the HydroPack water circulating unit, consistent with the concept of modularity, has several pumps in parallel (up to 3), to monitor the system load variations better and to regulate the water flow in the critical system starting (or restarting) stages so that outside servicing is avoided. The innovative and hi-tech features of SPINchiller give this series a much higher quality than can generally be found on the market today. These indoor water-cooled units may be combined with the dry coolers of the REM series. functions and features H2O Cooling only Water cooled Outdoor inst. Indoor inst. Refrig. R-410A EEV HYDRO PACK R-410A Herm. Scroll Water circuit reversal HydroPack Electronic Expansion Valve available configurations WSH-XSC (1) (2) (3) - D B 75D (4) (5) (6) EN T C (1) OPERATION: 4Standard unit (cooling only) 4H Heat pump with water circuit reversal (2) ENERGY RECOVERY: 4Not required 4D Partial recovery Carried out using braze-welded plate-type exchangers suited for recovering the desuperheating heat up to a maximum of 20% of the total unit heat. 4R Total recovery Carried out using braze-welded plate-type exchangers suited for 100% recovery of condensation heat for producing hot water. (3) LOW TEMPERATURE: 4Not required (Standard) 4B Low water temperature This version allows unit operation within the water and glycol mixing temperature range between +4°C and -7°C inclusive. 102 Two versions are available: - Unit for low temperatures only - Unit with double operating set-point. (4) ACOUSTIC CONFIGURATION: 4ST Standard 4EN Super Silenced This set-up is obtained by inserting the compressors in a soundproofed compartment. (5) APPLICATION: 4T Tower water (6) EXCHANGER APPROVALS: 4CE PED (European test) 4C Clivet (In-house test) accessories 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 Rubber antivibration mounts Outdoor installation Shut-off valve on compressor supply and return High and low pressure gauges HydroPack with 2 pumps Hydropack supply side with 2 pumps HydroPack with 2 pumps + 1 in stand-by Hydropack supply side with 2 pumps + 1 in stand-by HydroPack with 3 pumps Hydropack supply side with 3 pumps Connection set exchanger with hydronic group (supply side) Connection set exchanger with hydronic group (user side) Supply side anti-ice electric heaters for hydronic group User side anti-ice electric heaters for hydronic group Steel mesh filter on supply side Steel mesh filter on user side 2-way modulating valve 4 4 4 4 4 4 4 4 4 4 ■ 4 4 ■ 4 Set point compensation with 0-10 V signal Set point compensation with 4-20 mA signal Set point compensation with fresh air sensor Set point compensation with according to outdoor enthalpy Phase monitor Shunt capacitors (power factor > 0,9) Soft Start CAN/MODBUS serial converter kit CAN/LonWorks serial converter kit Data logger Master-slave operation Free contacts for compressor status Remote control with remote microprocessor control HYDRONIC ■ 4 Key to symbols: ■ Accessories supplied separately. technical data Sizes 4 Cooling capacity Total input EER EUROVENT ESEER 4 Heating capacity Total input COP Number of refrigerant circuits Number and type of compressors ST Sound pressure level EN Sound pressure level Power supply (1) (1) (2) (2) (3) (3) kW kW kW kW dB(A) dB(A) V/Ph/Hz 65D 195 41,5 4,70 6,11 224 51,2 4,38 70D 207 44,5 4,65 6,15 237 55,0 4,31 75D 223 47,6 4,68 5,87 257 58,2 4,42 80D 234 50,3 4,65 6,03 269 61,6 4,37 73 64 74 64 74 65 74 65 85D 251 53,7 4,67 5,88 289 64,9 4,45 90D 100D 110D 286 312 334 59,8 65,4 70,5 4,78 4,77 4,74 6,02 5,99 6,15 327 356 383 73,2 79,9 86,6 4,47 4,46 4,42 2 4 SCROLL 74 74 76 76 66 66 67 68 400/3/50 115D 353 75,7 4,66 6,09 407 93,1 4,37 120D 371 79,6 4,66 6,07 428 98,2 4,36 135E 406 86,6 4,69 6,10 466 107 4,36 150F 440 94,2 4,67 6,28 506 115 4,40 76 68 76 68 5 SCROLL 76 68 76 68 165F 497 106 4,69 6,21 574 130 4,42 180F 560 120 4,67 6,24 646 147 4,39 6 SCROLL 77 77 68 69 Data referred to the following conditions: (1) (2) Internal exchanger water = 12/7°C; external exchanger water = 30/35°C; Internal exchanger water = 12/7°C; external exchanger water = 40/45°C; (3) Sound levels refer to units with full load under nominal test conditions. The sound pressure is measured at 1 m from the external surface of the unit in open field conditions. dimensions and clearances Sizes Length (A) Width (B) Height (C) 4(A1) (A2) (B1) (B2) C 65D 2510 850 1890 1000 1500 1000 700 70D 2510 850 1890 1000 1500 1000 700 75D 2510 850 1890 1000 1500 1000 700 80D 2510 850 1890 1000 1500 1000 700 85D 2510 850 1890 1000 1500 1000 700 90D 2510 850 1890 1000 1500 1000 700 100D 2510 850 1890 1000 1500 1000 700 110D 2510 850 1890 1000 1500 1000 700 115D 2510 850 1890 1000 1500 1000 700 120D 2510 850 1890 1000 1500 1000 700 135E 2976 850 1890 1000 1500 1000 700 150F 2976 850 1890 1000 1500 1000 700 165F 2976 850 1890 1000 1500 1000 700 180F 2976 850 1890 1000 1500 1000 700 The above data refer to standard units. A1 A A2 CAUTION! mm mm mm mm mm mm mm B B2 B1 For trouble-free operation of the unit it is essential to maintain the clearances in green. 103 WDH-HE 2.220÷2.600 Water chiller Water cooled Indoor installation Capacity from 633 to 1711 kW SCREWLINE NEW The SCREWLine WDH-HE units are water chillers with extremely high efficiency that feature: HYDRONIC 4MORE EFFICIENCY, MORE VALUE - The innovative technology allows unbeatable efficiency both at full and at part load reaching a 12% better result compared to a A class unit. The required energy to maintain the required conditions will be consequently reduced and will increase the commercial value of the building. 4PERFECT FOR THE GREEN BUILDINGS - The extremely high efficiency values answer the requirements of the most demanding certification bodies like ECBC and LEED. The refrigerant is also Ecocompatible and its amount into the unit is much lower than most of the units available in the market especially the ones with flooded evaporator. This will allow to get more certification credits. 4RELIABLE TECHNOLOGY - The superb energetic performances derive from the use of high performances double screw compressors with economiser, electronic expansion valve and innovative shell and tube heat exchanger especially developed for the R134a refrigerant. Using two compressors allows also higher reliability, flexibility and lower inrush current. Unit listed on www.eurovent-certification.com 4MORE FLEXIBILITY FOR THE APPLICATIONS - It's suitable for the different types of terminals, like fancoils, radiant systems and chilled beams and it's also available in the low temperature configuration (Brine) suitable for applications that require high dehumidification or in the industrial processes. It's also compatible with the use with different thermal sources that are widely used in the big plants like cooling towers, dry coolers and geothermal systems. Eurovent Energy Efficiency Class functions and features H2O Cooling only EEV R-134a Water cooled Indoor inst. Refrig. R-134a Twin-screw semi. Electronic Expansion Valve available configurations (1) WDH-HE - B 2.300 (2) (3) (4) ST T CE (1) LOW TEMPERATURE: 4Not required 4B Low water temperature This version allows unit operation within the water and glycol mixing temperature range between +4°C and -7°C inclusive. - Unit for low temperatures only - Unit with double operating set-point The possibility of reducing the cooling capacity by shuttering the compressor depends on the working temperature. 104 (2) ACOUSTIC CONFIGURATION: 4ST Standard (3) ENERGY EFFICIENCY: 4P Well water 4T Tower water (4) EXCHANGER APPROVALS: 4CE PED (European test) 4C Clivet (In-house test) accessories ■ 4 ■ 4 ■ 4 4 4 4 4 4 Rubber antivibration mounts Pressure-controlled valve Remote control with remote microprocessor control MODBUS serial connection module BACNet serial connection module LonWorks serial connection module Master-slave operation Soft Start 4 4 4 4 4 4 4 Set point compensation with 4-20 mA signal Set point compensation with 0-10 V signal Set point compensation with fresh air sensor Set point compensation with according to outdoor enthalpy Magnetothermal circuit breakers Shunt capacitors (power factor > 0,9) Switchboard ventilation Key to symbols: HYDRONIC ■ Accessories supplied separately. technical data WDH-HE Eurovent ST 4Cooling capacity ST Total input ST EER EUROVENT ST ESEER ST Sound pressure level Number of refrigerant circuits Number and type of compressors Power supply (*) (1) (2) (3) kW kW dB(A) V/Ph/Hz 2.220 2.230 2.240 2.260 2.280 2.300 2.320 2.340 2.360 2.440 2.480 2.540 633 677 730 782 829 901 976 1045 1108 1226 1391 1549 113 121 130 139 148 161 174 184 195 216 244 272 5,60 5,60 5,62 5,63 5,60 5,60 5,61 5,68 5,68 5,68 5,70 5,69 6,61 6,66 6,63 6,69 6,67 6,66 6,62 6,64 6,65 6,64 6,67 6,61 80 80 82 82 83 83 83 82 82 82 82 82 2 2 DSW 400/3/50 2.600 1711 300 5,70 6,67 83 Data referred to the following conditions: (*) (1) The programme applies to air-cooled water chillers up to 600 kW and water-cooled water chillers up to 1500 kW. Internal exchanger water = 12/7°C; external exchanger water = 30/35°C; (2) (3) Sound levels refer to units with full load under nominal test conditions. The sound pressure is measured at 1 m from the external surface of the unit in open field conditions; DSW = twin-screw compressor dimensions and clearances Sizes ST Length (A) ST Width (B) ST Height (C) ST (A1) ST (A2) ST (B1) ST (B2) ST Weight in oper. C B1 A2 B B2 CAUTION! mm mm mm mm mm mm mm kg 2.220 4900 1460 2000 700 700 1000 1400 4400 2.230 4900 1460 2000 700 700 1000 1400 4450 2.240 4900 1460 2000 700 700 1000 1400 4500 2.260 4900 1520 2090 700 700 1000 1400 4750 2.280 4900 1520 2090 700 700 1000 1400 4800 2.300 4900 1520 2090 700 700 1000 1400 5100 2.320 4900 1520 2090 700 700 1000 1400 5450 2.340 4900 1620 2240 700 700 1000 1400 6320 2.360 4900 1620 2240 700 700 1000 1400 6360 2.440 4900 1620 2370 700 700 1000 1400 7000 2.480 4970 1620 2410 700 700 1000 1400 7480 2.540 4970 1620 2410 700 700 1000 1400 8000 2.600 4970 1620 2410 700 700 1000 1400 8250 The above data refer to standard units. A A1 For trouble-free operation of the unit it is essential to maintain the clearances in green. 105 WDH 2.160÷2.600 Water chiller Water cooled Indoor installation Capacity from 408 to 1537 kW SCREWLINE HYDRONIC The experience gained by Clivet in the high-capacity chiller sector has resulted in the WDH series, with the following features: 4EFFICIENCY - Eurovent energy efficiency Class A and B thanks to the new high capacity screw compressors and to the shell-and-tube exchangers specially developed for the gas R-134a: the best compromise to boost efficiency while limiting costs. The compressors are managed with continuous adjustment of the capacity. The heat exchangers are specifically sized for best adaptation to the other parts of the refrigerant circuit. The latter is fitted with an economiser exchanger for further operating efficiency; 4SELF-ADAPTATION - New, modern and intelligent electronic control directly developed by Clivet. This customisation allows better management of all the circuit components. Continual adapting of chiller operating parameters to the load conditions of the system in which it is installed reduces consumption while the working life of the parts increases; 4STURDINESS - Load-bearing frame in enamelled hot-galvanised sheet metal with semi-hermetic double-screw compressors and shell-and-tube evaporator ensuring reliability and constant performance. These units may be combined with the dry coolers of the REM series. Unit listed on www.eurovent-certification.com Eurovent Energy Efficiency Class (Config. CLA) Eurovent Energy Efficiency Class (Config. CLB) functions and features H2O Cooling only EEV R-134a Water cooled Indoor inst. Refrig. R-134a Twin-screw semi. Water circuit reversal (WDHH) Electronic Expansion Valve available configurations WDH-3 (1) (2) (3) - R B 2.300 (4) (5) (6) (7) CLA EN T CE (1) OPERATION: 4Standard unit (cooling only) 4H Heat pump with water circuit reversal (2) ENERGY RECOVERY: 4Not required (Standard) 4D Partial recovery Carried out using tube bundle exchargers suited for recovering the desuperheating heat up to a maximum of 15% of the total unit heat. 4R Total recovery Carried out using tube bundle exchargers suited for 100% recovery of condensation heat for producing hot water. (3) LOW TEMPERATURE: 4Not required (Standard) 4B Low water temperature This version allows unit operation within the water and glycol mixing temperature range between +4°C and -7°C inclusive. - Unit for low temperatures only - Unit with double operating set-point 106 The possibility of reducing the cooling capacity by shuttering the compressor depends on the working temperature. (4) ENERGY EFFICIENCY CLASS: 4CLA Class "A" Energy efficiency with EER greater than or equal to 5,05. 4CLB Class "B" Energy efficiency with EER inclusive between 4,65 and 5,05 . (5) ACOUSTIC CONFIGURATION: 4ST Standard 4EN Super Silenced This set-up is obtained by inserting the compressors in a soundproofed compartment. (6) APPLICATION: 4P Well water 4T Tower water (7) EXCHANGER APPROVALS: 4CE PED (European test) 4C Clivet (In-house test) accessories 4 4 ■ 4 4 ■ 4 4 4 4 4 4 Cooling only operation Operation with reversibility on water circuit Rubber antivibration mounts Shut-off valve on compressor supply and return Pressure-controlled valve Set point compensation with 0-10 mA signal Set point compensation with 4-20 mA signal Set point compensation with fresh air sensor Set point compensation with according to outdoor enthalpy General isolating switch 4 4 4 4 4 ■ 4 4 4 ■ 4 Magnetothermal circuit breakers Soft Start Shunt capacitors (power factor > 0,9) CAN/MODBUS serial converter kit CAN/LonWorks serial converter kit Master-slave operation Free contacts for compressor status Free contacts for compressor status and enabling Remote control with remote microprocessor control Key to symbols: HYDRONIC ■ Accessories supplied separately. technical data WDH-3 CLA Eurovent 4 Cooling capacity Total input EER EUROVENT ESEER 4 Heating capacity Total input ST Sound pressure level EN Sound pressure level (*) (1) (2) (4) (4) WDH-3 CLB Eurovent 4 Cooling capacity Total input EER EUROVENT ESEER 4 Heating capacity Total input ST Sound pressure level EN Sound pressure level Number of refrigerant circuits Number and type of compressors Power supply kW kW kW kW dB(A) dB(A) 2.160 2.180 2.220 2.250 2.280 2.300 2.320 2.340 2.360 2.420 2.450 2.480 2.540 2.600 468 536 610 697 758 831 900 960 1011 1169 1209 1248 1448 1537 92,6 106,1 119 137 150 164 177 188 199 230 238 247 286 303 5,05 5,05 5,14 5,07 5,05 5,08 5,07 5,09 5,07 5,08 5,07 5,06 5,06 5,08 5,75 5,75 5,85 5,77 5,75 5,78 5,78 5,80 5,77 5,78 5,77 5,76 5,76 5,78 548 627 727 814 892 976 1056 1131 1197 1375 1424 1472 1720 1812 111 126 150 168 185 203 221 236 251 285 295 305 346 380 81 81 83 83 84 84 84 83 83 83 83 83 84 84 72 73 74 74 75 74 74 74 75 74 73 74 77 77 2.160 2.180 2.220 2.250 2.280 2.300 2.320 2.340 2.360 2.420 2.450 2.480 2.540 2.600 (*) (1) (2) (4) (4) (3) kW kW kW kW dB(A) dB(A) V/Ph/Hz 408 87,0 4,69 5,55 473 108 81 72 455 97,5 4,67 5,52 528 120 81 73 562 119 4,73 5,60 649 147 82 73 620 131 4,72 5,58 718 162 82 73 698 148 4,71 5,56 809 185 83 74 773 163 4,73 5,59 894 202 83 75 828 903 952 993 178 188 197 209 4,66 4,80 4,82 4,74 5,51 5,68 5,70 5,60 962 1039 1095 1148 219 232 244 259 83 83 83 83 76 76 76 76 2 2 DSW 400/3/50 1049 224 4,68 5,53 1217 276 83 76 1171 247 4,74 5,60 1358 304 84 76 1295 272 4,75 5,62 1503 338 84 77 1458 309 4,72 5,58 1692 382 84 77 Data referred to the following conditions: (*) (1) (2) The programme applies to air-cooled water chillers up to 600 kW and water-cooled water chillers up to 1500 kW. Internal exchanger water = 12/7°C; external exchanger water = 30/35°C; Internal exchanger water = 12/7°C; external exchanger water = 40/45°C; (3) (4) DSW = twin-screw compressor Sound levels refer to units with full load under nominal test conditions. The sound pressure is measured at 1 m from the external surface of the unit in open field conditions. dimensions and clearances C B1 A2 B B2 CAUTION! A A1 For trouble-free operation of the unit it is essential to maintain the clearances in green. WDH-3 CLA ST Length (A) EN Length (A) ST-EN Width (B) ST Height (C) EN Height (C) 4 (A1) (A2) (B1) (B2) ST Weight in oper. EN Weight in oper. mm mm mm mm mm mm mm mm mm kg kg 2.160 2.180 2.220 2.250 2.280 2.300 2.320 2.340 2.360 2.420 2.450 2.480 2.540 2.600 3534 3534 3601 3601 3729 4061 4361 4361 4361 4657 4657 4657 4678 4678 3831 3831 3831 3831 4250 4336 4746 4746 4746 4746 4746 4746 4746 4746 1398 1398 1398 1425 1425 1425 1425 1425 1425 1425 1425 1425 1425 1425 1711 1711 2018 2018 2018 2018 2018 2018 2018 2146 2146 2146 2146 2146 1891 1891 1891 1891 2182 2182 2182 2182 2182 2245 2245 2245 2245 2245 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 2926 2995 3577 3726 4122 4602 5074 5093 5112 5931 6028 6075 6118 6152 3254 3323 3900 4053 4463 4919 5519 5538 5557 6376 6473 6520 6563 6597 WDH-3 CLB ST Length (A) EN Length (A) ST-EN Width (B) ST Height (C) EN Height (C) 4(A1) (A2) (B1) (B2) ST Weight in oper. EN Weight in oper. mm mm mm mm mm mm mm mm mm kg kg 2.160 2.180 2.220 2.250 2.280 2.300 2.320 2.340 2.360 2.420 2.450 2.480 2.540 2.600 3526 3526 3534 3534 3534 3933 3894 3902 3902 3902 3902 4678 4678 4678 3820 3820 3831 3831 3831 4233 4233 4316 4316 4316 4316 4749 4749 4749 1398 1398 1398 1425 1425 1425 1425 1425 1425 1425 1425 1425 1425 1425 1640 1640 1871 1871 1871 1980 1980 2083 2083 2083 2083 2083 2083 2146 1781 1781 1891 1891 1891 2106 2106 2182 2182 2182 2182 2182 2182 2245 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 2576 2612 3201 3264 3304 3656 3988 4367 4377 4411 4542 5384 5393 5881 2808 2845 3211 3294 3308 3654 3975 4195 4206 4234 4375 5240 5245 5728 The above data refer to standard units. 107 REM 75C÷2.440 HYDRONIC Liquid chiller Air cooled Outdoor installation Capacity from 195 to 980 kW The REM dry coolers may be combined with all the water-cooled water coolers and are made so as to occupy the least space possible. Remote dispersal of heat into the ambient air means that noise can be transferred to where it causes least disturbance. They are available in various soundproofing configurations and with various exchanger coils for best adaptation to their surroundings. Great care has been taken over all the finishes to ensure maximum resistance to weathering even under extreme conditions of use. functions and features AIR Air cooled H 2O Outdoor inst. Refrig. Water available configurations REM 100D (1) (2) ST T (1) ACOUSTIC CONFIGURATION: 4ST Standard 4EN Super Silenced This set-up is obtained by reducing the fan speed of rotation (2) ENERGY EFFICIENCY: 4T Temperate climate (Standard) 108 accessories 4 4 4 4 4 Exchanger coil in copper/aluminium with acrylic coating Copper/copper exchanger coil Service switches for enabling fans Fan speed control kit Power and control board with isolating switch Key to symbols: HYDRONIC ■ Accessories supplied separately. technical data Sizes ST ST ST ST EN EN EN EN Power Rated output Air flow rate Number of fans Sound pressure level Rated output Air flow rate Number of fans Sound pressure level supply (1) Sizes ST ST ST ST EN EN EN EN Power Rated output Air flow rate Number of fans Sound pressure level Rated output Air flow rate Number of fans Sound pressure level supply (1) (2) (1) (2) (2) (1) (2) 75C 195 16300 3 57 154 12000 3 48 kW l/s n° dB(A) kW l/s n° dB(A) V/Ph/Hz 75D 248 24900 135F 354 36650 58 235 17650 60 299 27650 51 53 400/3/50 4 58 203 18900 150F 436 34700 2.200 491 49850 60 345 25700 61 402 37700 53 54 6 4 2.280 686 60900 2.300 760 59300 2.360 816 83650 62 600 43950 63 683 64850 55 56 2.400 883 81900 12 63 725 62500 12 56 10 55 61 445 37000 8 10 62 555 45950 2.230 548 49000 8 6 51 2.260 608 47750 8 61 481 35500 8 54 kW l/s n° dB(A) kW l/s n° dB(A) V/Ph/Hz 100D 297 23800 54 2.440 980 79000 63 790 60000 56 400/3/50 Data referred to the following conditions: (1) Data in accordance with EN 1048 - Ethylene glycol 34% - External air temperature 25°C - Tin = 40°C - Tout = 35°C (2) Sound levels refer to units with full load under nominal test conditions. The sound pressure is measured at 10 m from the external surface of the unit in open field conditions. dimensions and clearances leave free Sizes Length (A) Width (B) Height (C) 4(A1) (A2) (B1) (B2) C A1 75C 3250 1095 2030 1000 700 1300 1300 75D 3050 2195 1930 1000 700 1300 1300 100D 3050 2195 1930 1000 700 1300 1300 135F 4550 2195 1930 1000 700 1300 1300 150F 4550 2195 1930 1000 700 1300 1300 2.200 5090 2326 1910 1000 700 1300 1300 2.230 5090 2326 1910 1000 700 1300 1300 2.260 5090 2326 1910 1000 700 1300 1300 2.280 6200 2326 1910 1000 700 1300 1300 2.300 6200 2326 1910 1000 700 1300 1300 2.360 7250 2326 1910 1000 700 1300 1300 2.400 7250 2326 1910 1000 700 1300 1300 2.440 7250 2326 1910 1000 700 1300 1300 The above data refer to standard units. A A2 CAUTION! mm mm mm mm mm mm mm B1 B B2 For trouble-free operation of the unit it is essential to maintain the clearances in green. 109 ME 17÷422 HYDRONIC Water chiller Condenserless Indoor installation Capacity from 4,8 to 138 kW The condenserless water chillers of the ME series are units designed for indoor installation to be matched with a remote condenser. These units are particularly suitable for noise-sensitive environments and for resolving problems concerning the space occupied by a packaged chillers. The condenserless water chillers in the ME series have been designed for combination with the air-cooled condensers of the CE series. + CE functions and features R-407C Cooling only Condenserless Indoor inst. Refrig. R-407C Herm. Scroll available configurations (1) ME S 17 (2) (3) CE B (1) VERSION: 4S Standard 4P Pump Includes water circulating pump, expansion tank, differential pressure switch, filling unit with pressure gauge, water side safety valve and air valve. (only sizes 17÷51) (2) EXCHANGER APPROVALS: 4CE PED (European test) 110 (3) LOW TEMPERATURE: 4B Low water temperature This version allows unit operation within the water and glycol mixing temperature range between +5°C and -7°C inclusive. accessories ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 Manifold for unit with double exchanger Serial communication module PC/BMS MODBUS for 1 unit (Master) Serial communication module PC/BMS MODBUS from 2 to 254 units (Slave) Steel mesh filter on water side Daily and weekly programming clock Phase monitor Remote control with remote microprocessor control 4 ■ 4 Supply voltage 400/3/50 without neutral (sizes 17-21) Liquid line solenoid valve Key to symbols: HYDRONIC ■ Accessories supplied separately. technical data Sizes 4 Cooling capacity Total input EER EUROVENT Number of refrigerant circuits Number and type of compressors Sound pressure level Power supply (1) (1) (2) Sizes 4 Cooling capacity Total input EER EUROVENT Number of refrigerant circuits Number and type of compressors Sound pressure level Power supply (1) (1) (2) kW kW dB(A) V/Ph/Hz kW kW dB(A) V/Ph/Hz 17 4,79 1,49 3,21 49 21 5,99 1,91 3,14 25 7,28 2,23 3,26 31 8,39 2,64 3,18 49 49 230/1/50 49 41 10,8 3,12 3,46 51 12,8 3,86 3,32 61 15,3 4,47 3,42 1 1 SCROLL 50 50 50 102 25,7 7,69 3,34 142 34,2 10,1 3,39 162 37,5 11,7 3,21 182 45,1 14,3 3,15 202 52,5 16,4 3,20 53 53 62 62 63 71 17,1 5,07 3,37 81 18,8 5,84 3,22 50 59 400/3/50 222 58,5 18,3 3,20 2 2 SCROLL 64 400/3/50 91 22,5 7,12 3,16 101 26,3 8,19 3,21 121 32,3 10,1 3,20 59 60 62 242 64,5 20,1 3,21 292 82,1 24,9 3,30 322 96,9 29,4 3,30 362 113 33,9 3,33 422 138 41,6 3,32 65 66 66 66 66 Data referred to the following conditions: (1) (2) Internal exchanger water = 12/7°C; dew point = 50°C Sound levels refer to units with full load under nominal test conditions. The sound pressure is measured at 1 m from the external surface of the unit in open field conditions. functional spaces dimensions and clearances 17÷121 C A1 A A2 B1 B B2 102÷422 C A1 A A2 CAUTION! B B2 Sizes Length (A) Width (B) Height (C) 4(A1) (A2) (B1) (B2) Weight in oper. mm mm mm mm mm mm mm kg 17 402 487 790 300 300 500 300 77 21 402 487 790 300 300 500 300 80 Sizes Length (A) Width (B) Height (C) 4(A1) (A2) (B1) (B2) Weight in oper. mm mm mm mm mm mm mm kg 102 802 602 790 300 300 500 300 158 142 802 602 790 300 300 500 300 193 25 402 487 790 300 300 500 300 85 162 802 602 915 300 300 500 300 232 31 402 487 790 300 300 500 300 87 182 802 602 915 300 300 500 300 232 41 402 602 790 300 300 500 300 91 202 802 602 915 300 300 500 300 239 51 402 602 790 300 300 500 300 92 61 402 602 790 300 300 500 300 93 222 802 602 915 300 300 500 300 245 71 402 602 790 300 300 500 300 93 242 802 602 915 300 300 500 300 250 81 402 602 915 300 300 500 300 113 292 580 1062 1538 300 300 500 300 410 91 402 602 915 300 300 500 300 113 322 580 1062 1538 300 300 500 300 445 101 402 602 915 300 300 500 300 113 121 402 602 915 300 300 500 300 119 362 580 1062 1538 300 300 500 300 468 422 580 1062 1538 300 300 500 300 520 The above data refer to standard units. B1 For trouble-free operation of the unit it is essential to maintain the clearances in green. 111 CE 25÷602 HYDRONIC Remote condenser Air cooled Outdoor installation Capacity from 9,1 to 277 kW The remote air-cooled condensers in the CE series are designed for connecting to the indoor evaporating units of the ME. They are available in three soundproofing versions: standard (ST), low noise (LN) and extra low noise (EN), to satisfy even the severest of requirements in terms of noise limits. They are fitted with axial-flow fans with open inlet and outlet, suitable for installation outdoors, with large exchange surfaces and fan speed adjustment (optional) to optimise the cooling performance of the coupled units. All the units comply with Clivet’s high quality standards and undergo severe tests during assembly. functions and features AIR Cooling only Air cooled R-407C Outdoor inst. Refrig. R-407C available configurations CE 71 (1) (2) ST T (1) ACOUSTIC CONFIGURATION: 4ST Standard 4LN Silenced 4EN Super Silenced (2) FAN CONNECTION (sizes 302÷602): 4S Star connection 4T Delta connection 112 accessories 4 4 ■ 4 4 ■ 4 ■ 4 4 4 Condenser coil in copper/copper Condenser coil with double circuit Mounts for horizontal condenser coil installation Fan switch (sizes 302÷602) Liquid receiver kit Low temperature liquid receiver kit Low external air temperature pressure-switch device Sub-cooling circuit 4 ■ 4 General isolating switch (sizes 25÷201) Packing in wooden case Key to symbols: technical data Sizes ST Rated output ST Air flow rate ST Sound pressure level LN Rated output LN Air flow rate LN Sound pressure level EN Rated output EN Air flow rate EN Sound pressure level Number and diameter of fans ST/LN Power supply EN Power supply (1) (2) (1) (2) (1) (2) kW l/s dB(A) kW l/s dB(A) kW l/s dB(A) n°/mm V/Ph/Hz V/Ph/Hz Sizes ST Rated output (1) ST Air flow rate ST Sound pressure level (2) LN Rated output (1) LN Air flow rate LN Sound pressure level (2) EN Rated output (1) EN Air flow rate EN Sound pressure level (2) Number and diameter of fans Power supply ∆ Y ∆ Y ∆ Y ∆ Y ∆ Y ∆ Y ∆ Y ∆ Y ∆ Y kW kW l/s l/s dB(A) dB(A) kW kW l/s l/s dB(A) dB(A) kW kW l/s l/s dB(A) dB(A) n°/mm V/Ph/Hz 25 9,10 1039 56 6,62 639 43 5,86 533 40 31 41 51 12,1 13,5 17,3 961 910 1956 55 55 58 8,70 9,57 12,9 606 577 1233 43 42 46 7,50 8,19 11,3 497 475 1015 40 39 43 1/450 2/450 302 110 95,9 12271 9539 74 67 93,7 84,7 9167 7720 67 62 71,1 59,7 5843 4518 58 52 322 141 119 11659 8938 74 67 118 103 8733 7224 67 62 84,6 68,5 5507 4201 58 52 2/800 61 20,2 2538 59 15,3 1614 46 13,7 1362 44 71 91 101 121 24,2 29,7 34,5 41,3 2150 2542 3911 3707 57 59 61 61 18,1 21,6 25,7 30,3 1413 1615 2467 2343 45 46 49 48 16,1 19,1 22,6 26,2 1201 1363 2030 1923 42 44 46 45 3/450 4/450 230/1/50 400/3/50 402 158 129 11092 8407 74 67 128 110 8323 6789 67 62 88,4 70,6 5199 3932 58 52 452 170 149 18426 14330 76 69 145 132 13765 11597 69 64 111 93,0 8776 6789 60 54 502 213 180 17517 13435 76 69 177 155 13119 10858 69 64 127 103 8276 6316 60 54 3/800 141 51,5 6617 71 43,8 5086 63 37,5 3981 55 161 181 60,0 72,7 6488 6195 70 70 50,5 58,9 4945 4560 62 62 42,8 48,7 3849 3509 54 54 3/630 552 238 195 16673 12643 76 69 193 165 12510 10161 69 64 133 106 7818 5914 60 54 201 79,5 5981 70 63,2 4337 62 51,3 3290 53 602 277 233 23375 17932 77 70 229 201 17506 14493 70 65 166 138 11045 8430 61 55 4/800 400/3/50 Data referred to the following conditions: (1) (2) Fresh air 35°C - Dew point 52,5°C Sound levels refer to units with full load under nominal test conditions. The sound pressure is measured at 1 m from the external surface of the unit in open field conditions. dimensions and clearances A2 C A B1 B B 2 CAUTION! A A1 For trouble-free operation of the unit it is essential to maintain the clearances in green. Sizes Length (A) Width (B) Height (C) 4(A1) (A2) (B1) (B2) Weight in oper. mm mm mm mm mm mm mm kg Sizes Length (A) Width (B) Height (C) 4(A1) (A2) (B1) (B2) Weight in oper. mm mm mm mm mm mm mm kg 25 31 41 51 61 71 91 101 121 141 1110 1110 1110 1790 1760 1760 1840 1840 1840 2690 490 490 490 490 490 490 500 595 595 595 585 585 585 585 590 590 735 1170 1170 1215 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 700 550 550 550 550 550 550 700 1100 1100 1200 550 550 550 550 550 550 700 1100 1100 1200 35 40 50 60 75 80 85 110 125 150 302 3097 820 1495 700 700 1450 1450 303 322 3097 820 1495 700 700 1450 1450 336 402 3097 820 1495 700 700 1450 1450 368 452 4407 820 1495 700 700 1450 1450 427 502 4407 820 1495 700 700 1450 1450 475 161 2690 595 1215 700 700 1200 1200 155 552 4407 820 1495 700 700 1450 1450 523 181 2690 595 1215 700 700 1200 1200 190 201 2690 595 1215 700 700 1200 1200 225 602 5717 820 1495 700 700 1450 1450 617 The above data refer to vertical coil version with horizontal airflow. 113 HYDRONIC ■ Accessories supplied separately. MSE-SC 65D÷180F Water chiller Condenserless Indoor/outdoor installation Capacity from 174 to 487 kW SPINCHILLER HYDRONIC The MSE-SC units belong to the SPINchiller family and therefore feature high energy efficiency, self-adaptation and reliability. They are conderserless units that may be combined with the remote condensers of the CEM series. Thanks to indoor installation and remote dispersal of heat into the ambient air, the noise may be transferred to where it causes less disturbance. 4Compactness: the width in the units up to 500 kW capacity has been reduced to just 85 cm so that they can pass through normal doorways. 4Easy connection to the service system plus a simple control system and easy maintenance drastically reduce work requiring specialised personnel and therefore installation costs. 4EFFICIENCY that increases as the heating load decreases, while guaranteeing maximum requested load when necessary. + 4The particular abundance of optional accessories allows customisation of the unit, also for special requirements both in the civil and technological air-conditioning sphere. In particular the optional for the HydroPack water circulating unit, consistent with the concept of modularity, has several pumps in parallel (up to 3), to monitor the system load variations better. CEM The innovative and hi-tech features of SPINchiller give this series a much higher quality than can generally be found on the market today. functions and features Cooling only Condenserless Indoor inst. Refrig. R-407C EEV HYDRO PACK R-407C Herm. Scroll HydroPack Electronic Expansion Valve available configurations MSE-SC (1) (2) D B 100D (3) (4) (5) EN T CE (1) ENERGY RECOVERY: 4Not required 4D Partial recovery Carried out using braze-welded plate-type exchangers suited for recovering the desuperheating heat up to a maximum of 20% of the total unit heat. (2) LOW TEMPERATURE: 4Not required 4B Low water temperature This version allows unit operation within the water and glycol mixing temperature range between +5°C and -7°C inclusive. Two versions are available: - Unit for low temperatures only - Unit with double operating set-point The possibility of reducing the cooling capacity by shuttering the compressor depends on the working temperature. 114 (3) ACOUSTIC CONFIGURATION: 4ST Standard 4EN Super Silenced This set-up is obtained by inserting the compressors in a soundproofed compartment. (4) ENERGY EFFICIENCY: 4T Temperate climate (Standard) (5) EXCHANGER APPROVALS: 4CE PED (European test) 4C Clivet (In-house test) accessories 4 ■ 4 4 4 4 4 4 4 ■ 4 4 4 4 Connection to CEM remote condensers Rubber antivibration mounts Outdoor installation Shut-off valve on compressor supply and return High and low pressure gauges HydroPack with 2 pumps HydroPack with 2 pumps + 1 in stand-by HydroPack with 3 pumps Steel mesh filter on user side User side anti-ice electric heaters for hydronic group Connection set exchanger with hydronic group (user side) Set point compensation with 4-20 mA signal 4 4 4 4 4 4 ■ 4 4 ■ 4 Set point compensation with fresh air sensor Set point compensation with according to outdoor enthalpy Phase monitor Shunt capacitors (power factor > 0,9) CAN/MODBUS serial converter kit CAN/LonWorks serial converter kit Master-slave operation Free contacts for compressor status Remote control with remote microprocessor control HYDRONIC Key to symbols: ■ Accessories supplied separately. technical data Sizes ST/EN 4 Cooling capacity ST/EN Total input ST/EN EER EUROVENT ST Sound pressure level EN Sound pressure level Number of refrigerant circuits Number and type of compressors Power supply (1) (2) (2) kW kW dB(A) dB(A) V/Ph/Hz 65D 174 55,1 3,15 72 67 70D 184 58,0 3,17 73 67 2 4 SCROLL 75C 205 60,9 3,37 76 70 1 3 SCROLL 75D 196 60,8 3,22 74 68 80D 206 63,7 3,23 75 69 2 4 SCROLL 90C 248 75,9 3,27 76 71 1 3 SCROLL 90D 100D 110D 238 271 305 72,4 81,1 91 3,28 3,34 3,34 76 76 76 70 71 71 4 SCROLL 400/3/50 120D 135F 150F 165F 180F 332 360 405 447 487 101 109 122 137 152 3,27 3,32 3,33 3,27 3,21 76 78 79 80 80 70 72 73 74 74 2 6 SCROLL Data referred to the following conditions: (1) Internal exchanger water = 12/7°C; condensing temperature = 50°C (2) Sound levels refer to units with full load under nominal test conditions. The sound pressure is measured at 1 m from the external surface of the unit in open field conditions. dimensions and clearances Sizes Length (A) Width (B) Height (C) 4(A1) (A2) (B1) (B2) ST Weight in oper. EN Weight in oper. C A1 65D 2510 850 1876 1000 1500 1000 700 1172 1253 70D 2510 85 0 1876 1000 1500 1000 700 1235 1316 75C 2626 850 1876 1000 1500 1000 700 1169 1264 75D 2510 850 1876 1000 1500 1000 700 1310 1391 80D 2510 850 1876 1000 1500 1000 700 1363 1445 90C 2626 850 1876 1000 1500 1000 700 1169 1264 90D 2510 850 1876 1000 1500 1000 700 1478 1560 100D 2510 850 1876 1000 1500 1000 700 1576 1658 110D 2510 850 1876 1000 1500 1000 700 1576 1658 120D 2510 850 1876 1000 1500 1000 700 1576 1658 135F 2976 850 1876 1000 1500 1000 700 2070 2212 150F 2976 850 1876 1000 1500 1000 700 2241 2382 165F 2976 850 1876 1000 1500 1000 700 2241 2382 180F 2976 850 1876 1000 1500 1000 700 2241 2382 The above data refer to standard units. A A2 CAUTION! mm mm mm mm mm mm mm kg kg B B2 B1 For trouble-free operation of the unit it is essential to maintain the clearances in green. 115 MDE 2.160÷2.600 Water chiller Condenserless Indoor installation Capacity from 439 to 1385 kW SCREWLINE HYDRONIC The liquid chillers in the MDE range are units for indoor installation and are ideal in combination with the remote condensers in the CEM range. They are particularly suited in civil and industrial sector systems in the following applications: 4Buildings with architectural value - The chiller is normally installed in a service room and therefore completely concealed from sight, whereas the outdoor exchange section can be positioned remotely. 4Extremely low noise emission - Separated from the chiller, the outdoor exchange section can be selected and sized as required to reduce noise emission. 4Particularly severe climates - The two section solution makes it possible to avoid having an outdoor water system and therefore having to perform the winter emptying needed to protect it against freezing. With MDE, the pipes between the two sections contain a refrigerant fluid and not water. The energy efficiency of the entire range is particularly high: all sizes use two compact two screw semi-hermetic compressors with continuous adjustment of the supplied cooling capacity. The shell and tube evaporators are specifically optimised to operate with ecological R134a refrigerant fluid and are provided with a standard electronic expansion valve. The MDE units are supplied standard with a double acting economiser, which further improves performance levels: The refrigerant supercooling involves greater cooling capacity, and injecting the refrigerant in a gaseous state into the compressor involves lower consumption. + CEM functions and features EEV R-134a Cooling only Condenserless Indoor inst. Refrig. R-134a Twin-screw semi. Electronic Expansion Valve available configurations MDE-3 (1) (2) D B 2.420 (3) (4) (5) EN T CE (1) ENERGY RECOVERY: 4Not required 4D Partial recovery Carried out using tube bundle exchargers suited for recovering the desuperheating heat up to a maximum of 20% of the total unit heat. (2) LOW TEMPERATURE: 4Not required (Standard) 4B Low water temperature This version allows unit operation within the water and glycol mixing temperature range between +4°C and -7°C inclusive. Two versions are available - Unit for low temperatures only - Unit with double operating set-point The possibility of reducing the cooling capacity by shuttering the compressor depends on the working temperature. 116 (3) ACOUSTIC CONFIGURATION: 4ST Standard 4EN Super Silenced This set-up is obtained by inserting the compressors in a soundproofed compartment. (4) ENERGY EFFICIENCY: 4T Temperate climate (Standard) (5) EXCHANGER APPROVALS: 4CE PED (European test) 4C Clivet (In-house test) accessories 4 ■ 4 4 4 4 4 4 4 4 Connection to CEM remote condensers Rubber antivibration mounts Shut-off valve on compressor supply and return Set point compensation with 4-20 mA signal Set point compensation with fresh air sensor Set point compensation with according to outdoor enthalpy General isolating switch Magnetothermal circuit breakers Shunt capacitors (power factor > 0,9) 4 4 ■ 4 4 4 ■ 4 CAN/MODBUS serial converter kit CAN/LonWorks serial converter kit Master-slave operation Free contacts for compressor status Free contacts for compressor status and enabling Remote control with remote microprocessor control Key to symbols: HYDRONIC ■ Accessories supplied separately. technical data Sizes Cooling capacity Total input EER EUROVENT Number of refrigerant circuits Number and type of compressors ST Sound pressure level EN Sound pressure level Power supply (1) (2) (3) (3) kW kW dB(A) dB(A) V/Ph/Hz 2.160 439 131 3,35 2.180 469 137 3,42 2.220 559 162 3,45 2.250 614 176 3,49 2.280 698 198 3,53 2.300 770 219 3,52 81 72 81 73 83 74 83 74 84 75 84 74 2.320 2.340 835 879 239 251 3,49 3,50 2 2 DSW 84 83 74 74 400/3/50 2.360 923 263 3,51 2.420 974 276 3,53 2.450 1002 286 3,50 2.480 1148 326 3,52 2.540 1262 358 3,53 2.600 1385 401 3,45 83 75 83 74 83 73 83 74 84 77 84 77 Data referred to the following conditions: (1) (2) Internal exchanger water = 12/7°C; condensing temperature = 50°C; DSW = twin-screw compressor (3) Sound levels refer to units with full load under nominal test conditions. The sound pressure is measured at 1 m from the external surface of the unit in open field conditions. dimensions and clearances C B1 A2 B B2 A Sizes Length (A) Width (B) Height (C) 4(A1) (A2) (B1) (B2) ST Weight in oper. EN Weight in oper. mm mm mm mm mm mm mm kg kg 2.160 3709 1244 1485 700 700 700 1500 2240 2469 2.180 3579 1244 1485 700 700 700 1500 2290 2581 2.220 3840 1244 1485 700 700 700 1500 2829 3105 2.250 3690 1271 1617 700 700 700 1500 2885 3161 2.280 3690 1271 1617 700 700 700 1500 2905 3181 2.300 4071 1244 1617 700 700 700 1500 3596 3922 2.320 4075 1271 1617 700 700 700 1500 3909 4248 2.340 4075 1271 1617 700 700 700 1500 3994 4320 2.360 4075 1271 1617 700 700 700 1500 3992 4320 2.420 4075 1271 1617 700 700 700 1500 4012 4340 2.450 4075 1271 1617 700 700 700 1500 4122 4408 2.480 4694 1271 1690 700 700 700 1500 5157 5644 2.540 4694 1271 1690 700 700 700 1500 5197 5684 2.600 4694 1271 1690 700 700 700 1500 5277 5764 A1 The above data refer to standard units. CAUTION! For trouble-free operation of the unit it is essential to maintain the clearances in green. 117 CEM 75C÷2.440 HYDRONIC Remote condenser Air cooled Outdoor installation Capacity from 250 to 1200 kW The CEM remote condensers may be combined with all the remote condenser liquid chillers and are made so as to occupy the least space possible. Remote condensation means that noise can be transferred to where it causes least disturbance, thereby achieving a highly appreciable working wellbeing. They are available in various soundproofing configurations and with various exchanger coils for best adaptation to their surroundings. Use of the condensation control gives the CEM remote condensers, latent load permitting, the extra possibility of obtaining considerably lower noise levels than a packaged chiller. Great care has been taken over all the finishes to ensure maximum resistance to weathering even under extreme conditions of use. functions and features AIR Cooling only Air cooled Outdoor inst. available configurations CEM 100D (1) (2) (3) ST T C (1) ACOUSTIC CONFIGURATION: 4ST Standard 4EN Super Silenced This set-up is obtained by reducing the fan speed of rotation. (2) ENERGY EFFICIENCY: 4T Temperate climate (Standard) (3) EXCHANGER APPROVALS: 4CE PED (European test) 4C CLIVET (In-house test) 118 accessories 4 4 4 4 4 4 Condenser coil in copper/aluminium with acrylic coating Condenser coil in copper/copper Service switches for enabling fans Kit for low external temperatures with variable fan speed (1 gas circuit) Kit for low external temperatures with variable fan speed (2 gas circuits) Power and control board with isolating switch (1 gas circuit) 4 4 Power and control board with isolating switch (2 gas circuits) Single gas circuit Key to symbols: HYDRONIC ■ Accessories supplied separately. technical data Sizes ST ST ST ST EN EN EN EN Power Rated output Air flow rate Number of fans Sound pressure level Rated output Air flow rate Number of fans Sound pressure level supply (1) Sizes ST ST ST ST EN EN EN EN Power Rated output Air flow rate Number of fans Sound pressure level Rated output Air flow rate Number of fans Sound pressure level supply (1) (2) (1) (2) (2) (1) (2) 75C 250 16100 3 57 200 12200 3 48 kW l/s n° dB(A) kW l/s n° dB(A) V/Ph/Hz 65D 280 25800 58 240 19350 51 150F 650 43800 kW l/s n° dB(A) kW l/s n° dB(A) V/Ph/Hz 90D 332 24600 4 58 276 18450 4 51 100D 380 23500 105F 410 38800 58 308 18000 60 350 28900 51 400/3/50 53 2.230 770 55700 2.280 834 57800 61 620 41600 62 678 43200 54 55 8 61 524 32700 2.300 990 54200 2.400 1070 80000 62 786 40500 63 890 59750 55 56 10 8 54 120F 495 37000 6 60 412 27600 6 53 135F 576 35300 60 462 26400 53 2.440 1200 77900 12 10 63 1000 58200 12 56 400/3/50 Data referred to the following conditions: (1) (2) Fresh air 30°C - Dew point 45°C Sound levels refer to units with full load under nominal test conditions. The sound pressure is measured at 10 m from the external surface of the unit in open field conditions. dimensions and clearances leave free Sizes Length (A) Width (B) Height (C) 4(A1) (A2) (B1) (B2) C A1 75C 3250 1095 2030 700 1000 1300 1300 65D 2950 2195 1930 700 1000 1300 1300 90D 2950 2195 1930 700 1000 1300 1300 100D 2950 2195 1930 700 1000 1300 1300 105F 4250 2195 1930 700 1000 1300 1300 120F 4250 2195 1930 700 1000 1300 1300 135F 4250 2195 1930 700 1000 1300 1300 150F 4250 2195 1930 700 1000 1300 1300 2.230 4880 2326 1910 700 1000 1300 1300 2.280 5900 2326 1910 700 1000 1300 1300 2.300 5900 2326 1910 700 1000 1300 1300 2.400 7050 2326 1910 700 1000 1300 1300 2.440 7050 2326 1910 700 1000 1300 1300 The above data refer to standard units. A A2 CAUTION! mm mm mm mm mm mm mm B1 B B2 For trouble-free operation of the unit it is essential to maintain the clearances in green. 119 GPA M0÷M9 HYDRONIC Pumping unit With storage tank Indoor (GPA 65)/outdoor (GPA 150) installation Capacity from 0,3 to 0,9 kW The GPA pumping units are designed for connection to Clivet units for producing chilled or hot water. They come complete with all the necessary electrical and water components for trouble-free operation of the system. The performance range of the installed centrifugal pumps makes the units suitable for all types of service systems. The units may be used on systems with primary and secondary circuit. functions and features H 2O Indoor inst. (GPA 65) Outdoor inst. (GPA 65) Refrig. Water available configurations GPA (1) (2) (3) - 1 150 (1) PUMP CAPACITY: 4M0, M1, M2, M3, M4, M5, M6, M7, M8, M9 (2) No. PUMPS: 41 Single pump (Always) (3) STORAGE TANK CAPACITY: 4150 from 65 to 150 litres 120 accessories 4 4 ■ 4 ■ 4 ■ 4 ■ 4 4 65-litre tank capacity 150-litre tank capacity Hose kit 0,8 m Hose kit 1,5 m Hose kit 2,0 m Ball valve kit for connection to the system Set-up for operation as primary circuit and fittings for secondary circuit Key to symbols: HYDRONIC ■ Accessories supplied separately. technical data Sizes 2-pole electric pump Rated output Rated absorbed current Expansion tank Capacity Maximum pressure Standard pressure Safety valve calibration Power supply GPA 65 Storage tank capacity GPA 150 Storage tank capacity kW A M0 M1 M2 M3 M4 M5 M6 M7 M8 M9 0,30 0,80 0,45 1,20 0,30 0,80 0,45 1,20 0,55 1,50 0,75 2,00 0,45 1,20 0,55 1,50 0,75 2,00 0,90 2,40 L kPa kPa kPa V/Ph/Hz 8 800 150 600 400/3/50 L 65 L 150 functional spaces dimensions and clearances C1 GPA 65 C A1 A A2 B1 B B2 C1 C GPA 150 A1 A A2 B1 B B2 GPA 65 Length (A) Width (B) Height (C) 4(A1) (A2) (B1) (B2) (C1) Weight in oper. mm mm mm mm mm mm mm mm kg GPA 150 Length (A) Width (B) Height (C) 4(A1) (A2) (B1) (B2) (C1) Weight in oper. mm mm mm mm mm mm mm mm kg M0 M1 M2 M3 M4 M0 M1 M2 M3 M4 470 600 790 600 600 700 1000 600 140 600 790 1186 600 600 600 600 600 240 M5 M6 M7 M8 M9 M5 M6 M7 M8 M9 The above data refer to standard units. CAUTION! For trouble-free operation of the unit it is essential to maintain the clearances in green. 121 GP1 GP2 00÷12 HYDRONIC Pumping unit With storage tank Outdoor installation Capacity from 0,5 to 2,6 kW GP1 Pumping unit to be combined with our units for the production of chilled or hot water, complete with all the indispensable water and electrical parts for correct operation of a central water plant. GP2 These differ from the GP1 because, in addition to the pumping and control functions, they also provide for water storage. The capacity of the tanks is 300 - 500 - 2x300 - 2x500 litres. functions and features H 2O Outdoor inst. Refrig. Water available configurations GP (1) (2) (3) (4) 1 00 1 300 (1) STORAGE TANK: 41 Without storage tank 42 With storage tank (2) PUMP CAPACITY: 400 From 00 to 12 (3) No. PUMPS: 41 Single pump 42 Double pump (4) STORAGE TANK CAPACITY: 4300 From 300 to 1000 litres 122 accessories Hose kit 1,5 m (1 exchanger x 1”) Hose kit 1,5 m (2 exchanger x 1”) ■ 4 Hose kit 1,5 m (1 exchanger x 2”-2”1/2) 4 Supply voltage 400/3/50+N Only GP1: 4 One pump 4 Two pumps Only GP2: 4 Storage tank 300 litres 1 Pump 4 Storage tank 300 litres 2 Pumps 4 Storage tank 500 litres 1 Pump 4 Storage tank 500 litres 2 Pumps 4 Storage tank 600 litres 1 Pump ■ 4 4 ■ 4 4 4 4 4 4 4 4 4 4 HYDRONIC 4 Storage tank 600 litres 2 Pumps Storage tank 1000 litres 1 Pump Storage tank 1000 litres 2 Pumps Three-way valve kit for storage tank from 300 litres to 500 litres Three-way valve kit for storage tank from 600 litres to 1000 litres 8 kW Add. el. heater for storage tank from 300 litres to 500 litres 8 kW Add. el. heater for storage tank from 600 litres to 1000 litres 12 kW Add. el. heater for storage tank from 300 litres to 500 litres 12 kW Add. el. heater for storage tank from 600 litres to 1000 litres 16 kW Add. el. heater for storage tank from 600 litres to 1000 litres 24 kW Add. el. heater for storage tank from 600 litres to 1000 litres Key to symbols: ■ Accessories supplied separately. technical data GP1 GP2 2-pole electric pump Rated output Rated absorbed current Expansion tank Capacity Maximum pressure Standard pressure Storage tank capacity (GP2) Safety valve calibration Power supply kW A 00 1 2 3 4 5 6 7 8 9 10 11 12 0,50 0,80 0,60 1,10 0,90 1,80 1,10 2,00 0,80 1,60 1,20 2,20 1,10 2,00 1,50 2,80 2,00 3,60 2,30 4,40 1,50 2,80 2,10 3,60 2,60 4,50 L kPa kPa L kPa V/Ph/Hz 12 x GP1 16 x GP2 (300L - 500L) 24 x GP2 (600L) 32 x GP2 (1000L) 800 150 300 - 500 - 600 - 1000 600 400/3/50 functional spaces dimensions and clearances C1 C A1 B2 B A A2 CAUTION! Sizes Length (A) Width (B) Height (C) 4(A1) (A2) (B1) (B2) (C1) GP1 Weight in oper. GP2 Weight in oper. mm mm mm mm mm mm mm mm 00 1 2 3 4 5 6 7 616 (GP1.1 - GP1.2) 831 (GP2.1 - 300-500) 514 (GP1.1 - GP1.2) 831 (GP2.1 - 300-500) 1299 (GP1.1 - GP1.2) 1502 (300) 2225 (500) 300 (GP1) 600 (GP2) 600 600 600 500 kg kg 8 9 10 11 12 1356 (GP2.2 - 600-1000) 867 (GP2.2 - 600-1000) 1502 (600) 2225 (1000) 70 130xGP2 (300) 170xGP2 (500) 205xGP2 (600) 260xGP2 (1000) The above data refer to standard units. B1 For trouble-free operation of the unit it is essential to maintain the clearances in green. 123 GP7 60÷63 HYDRONIC Pumping unit With storage tank Outdoor installation Capacity from 1,5 to 4 kW Pumping units with storage tank to be combined with units for the production of chilled or hot water, complete with the indispensable water and electrical parts for correct operation of the system. They have been designed for connection to our medium power units and come with steel tanks with a capacity of 2 x 300 and 2 x 500 litres. The range of capacity and head of the pumps makes these units suited to many types of systems. functions and features H 2O Outdoor inst. Refrig. Water available configurations GP7 (1) (2) (3) (4) S 60 2 1 (1) VERSION: 4S Standard (2) PUMP TYPE: 4CE 60, 61, 62, 63 (3) No. PUMPS: 41 Single pump 42 Double pump (4) STORAGE TANK CAPACITY: 41 600 litres 42 1000 litres 124 accessories 4 4 4 4 4 600-litre tank capacity 1000-litre tank capacity 12 kW additional electric heaters 8 kW additional electric heaters Water side protection differential pressure switch Key to symbols: HYDRONIC ■ Accessories supplied separately. technical data GP7 2-pole electric pump Rated output Rated absorbed current Expansion tank Capacity Maximum pressure Standard pressure Storage tank capacity Safety valve calibration Power supply kW A 60 61 62 63 1,50 3,60 2,20 4,90 3,00 6,50 4,00 8,50 L kPa kPa L kPa V/Ph/Hz 24 (600L) 32 (1000L) 800 150 600 1000 600 400/3/50 functional spaces dimensions and clearances Sizes Length (A) Width (B) Height (C) 4(A1) (A2) (B1) (B2) (C1) Weight in oper. C1 C mm mm mm mm mm mm mm mm kg 60 61 1355 911 62 1505 x (600L) 63 2225 x (1000L) 600 600 300 600 500 1355 1360 1390 1395 The above data refer to pumping units with 2 operating pumps and 1000 l storage tank. B1 A2 B B2 CAUTION! A1 A For trouble-free operation of the unit it is essential to maintain the clearances in green. 125 GPM 60÷99 HYDRONIC Pumping unit With storage tank Indoor/outdoor installation Capacity from 1,5 to 11 kW The GPM pumping units are modular and designed for connection to units for the production of chilled or hot water. They come complete with all the indispensable electrical and water components for correct operation of the system. They have been designed for connection to our high power units and may be supplied either separately or integrated into the structure of the chillers with semi-hermetic compressors. The range of capacity and head of the pumps makes these units suited to many types of systems, also thanks to the possibility of having a primary or primary/secondary circuit. The GPM units are factory assembled and tested and are ready for operation as soon as they are connected to the electricity and water supplies. functions and features H 2O Indoor inst. Outdoor inst. Refrig. Water available configurations GPM (1) (2) (3) (4) (5) S 60 2 A 1 (1) VERSION: 4S Standard 4P Primary/secondary (4) SET-UP: 4A Packaged (separate) 4M Packaged with unit (2) PUMP TYPE (5) Packaged with unit: 41 1200 litres 42 2400 litres (3) No. PUMPS: 41 Single pump 42 Double pump 126 accessories 4 4 4 ■ 4 Water side differential pressure switch Silenced 4-pole pumps 2 kW anti-ice electric heater with safety thermostat Shut-off valves for connection to the system (P version only) Key to symbols: HYDRONIC ■ Accessories supplied separately. technical data GPM No poles Electric pump Rated output Rated absorbed current Expansion tank Capacity Maximum pressure Standard pressure Storage tank capacity Safety valve calibration Power supply 60 61 62 63 68 69 2 70 71 78 79 80 1,5 3,6 2,2 4,9 3,0 6,5 4,0 8,5 2,2 4,9 3,0 6,5 4,0 8,5 5,5 11,5 5,5 11,5 7,5 15,5 11,0 22,0 kW A L kPa kPa L kPa V/Ph/Hz GPM No poles Electric pump Rated output Rated absorbed current Expansion tank Capacity Maximum pressure Standard pressure Storage tank capacity Safety valve calibration Power supply 74 800 150 1200 (2400 optional) 600 400/3/50 83 85 87 90 91 - 92 93 94 98 99 2,2 5,2 4,0 8,7 5,5 12,4 5,5 12,4 7,5 15,8 4 kW A 0,8 2,1 1,5 3,6 2,2 5,2 1,1 2,8 1,5 3,6 L kPa kPa L kPa V/Ph/Hz 74 800 150 1200 (2400 optional) 600 400/3/50 dimensions and clearances GPM Length (A) 1200L Width (B) 2400L Width (B) Height (C) 4 (A1) (A2) (B1) (B2) 1200L Weight in oper. 2400L Weight in oper. C GPM A1 B2 B A A2 CAUTION! B1 For trouble-free operation of the unit it is essential to maintain the clearances in green. Length (A) 1200L Width (B) 2400L Width (B) Height (C) 4 (A1) (A2) (B1) (B2) 1200L Weight in oper. 2400L Weight in oper. mm mm mm mm mm mm mm mm kg kg mm mm mm mm mm mm mm mm kg kg 60 61 62 63 68 1902 3804 1906 3812 1915 3830 1924 3848 1926 3852 83 85 87 90 1929 3858 1945 3890 1964 3928 1954 3908 69 2040 1260 2520 2113 700 700 700 700 1922 3844 91 70 71 78 79 80 1932 3864 1960 3920 1976 3952 1978 3956 2024 4048 92 2040 1260 2520 2113 700 700 700 700 1954 1983 3908 3966 93 94 98 99 2048 4096 2060 4120 2068 4136 2070 4140 The above data refer to standard units. 127 ELFOSPACE OUT-V e OUT-H 3÷31 Water terminal unit Cased vertical and horizontal indoor installation Capacity from 1,5 to 9 kW ELFOSPACE ELFOSpace OUT is the cased water terminal for use in the commercial sector. Muted lines that blend in with any decor. The available controls are simple and user-friendly, satisfying the most varied of requirements, with top-of-the-range electronic control designed for connection to the ELFOControl or general supervisors. Low noise operation and easy to clean. These are the concepts behind the development of ELFOSpace, the last generation room terminal unit that is ideal for any installation. Ten sizes available with an almost countless number of accessories for resolving any service application requirement. The ELFOSpace OUT-V series has been designed specifically for cased vertical installation and the ELFOSpace OUT-H range for cased horizontal installation. HYDRONIC OUT-H OUT-V functions and features H 2O Heating-Cooling Indoor inst. Cased vertical inst. (OUT-V) Cased horizontal inst. (OUT-H) Refrig. Water ELFOControl available configurations Necessary configuration strings for supplying the unit with the indicated elements/accessories already mounted on the appliance. Certain accessories may also be supplied separately, as indicated in the “accessories supplied separately” list. ELFOSPACE OUT-H 3 References for position of fittings: - vertical fan coils: right and left defined by standing in front of the appliance; - horizontal fan coils: right and left defined by standing in the airflow (with the air blowing on your face). (1) (2) (3) (4) (5) (6) (7) R3 TR - SX - - - (1) AIR RETURN: 4R3 Return from below (Standard) 4RP Rear return (2) CONTROLS: 4TR Fan terminal block (Standard) 4TRM Terminal block with minimum safety thermostat 4CTS Clivet.Talk.Terminal Space electronics 4CTR Clivet.Talk.Terminal Room electronics (3) WATER COIL / ELECTRIC HEATER: 4Not required (Standard) 4B14T 1-row additional coil for 4-pipe syst. (sizes 3,7,11,17,25) 4RE With electric heater (4) WATER FITTINGS: 4SX Left-hand fittings (Standard) 4DX Right-hand fittings (5) VALVES: ELFOSPACE OUT-V 3 (1) (2) (3) (4) (5) (6) (7) R3 TR - SX - - - (1) AIR RETURN: 4R3 Return from below (Standard) 4RF Front return (2) CONTROLS: 4TR Fan terminal block (Standard) 4TRM Terminal block with minimum safety thermostat 4HID-F1 3-speed selector + on/off 4HID-F2 Bulb thermostat 4HID-F3 Bulb thermostat with remote S/W 4HID-F4 Bulb thermostat with minimum safety thermostat 4HID-F5 Bulb thermostat with electric heater control 4HID-F6 Electronic multifunction room thermostat 4CTS Clivet.Talk.Terminal Space electronics 4CTRD Clivet.Talk.Terminal Room electronics with unit on-board display (3) WATER COIL / ELECTRIC HEATER: 4Not required (Standard) 4B14T 1-row additional coil for 4-pipe syst. (sizes 3,7,11,17,25) 4RE With electric heater 128 4Not required (Standard) 4KBI2 2-pipe system water balancing kit 42V2 2-way on/off valve 2-pipe system 43V2 3-way on/off valve 2-pipe system 410V2 3-way 0-10V valve 2-pipe system 4KBI4 4-pipe system water balancing kit (sizes 3,7,11,17,25) 42V4 2-way on/off valve 4-pipe system (sizes 3,7,11,17,25) 43V4 3-way on/off valve 4-pipe system (sizes 3,7,11,17,25) 410V4 3-way 0-10V valve 4-pipe system (sizes 3,7,11,17,25) (6) ADDITIONAL TRAY: 4Not required (Standard) 4BRODX With additional tray r.h. water fittings 4BROSX With additional tray l.h. water fittings (7) SERIAL PORT: 4Not required (Standard) 4SP1 RS485 remote communication serial port (4) WATER FITTINGS: 4SX Left-hand fittings (Standard) 4DX Right-hand fittings (5) VALVES: 4Not required (Standard) 4KBI2 2-pipe system water balancing kit 42V2 2-way on/off valve 2-pipe system 43V2 3-way on/off valve 2-pipe system 410V2 3-way 0-10V valve 2-pipe system 4KBI4 4-pipe system water balancing kit (sizes 3,7,11,17,25) 42V4 2-way on/off valve 4-pipe system (sizes 3,7,11,17,25) 43V4 3-way on/off valve 4-pipe system (sizes 3,7,11,17,25) 410V4 3-way 0-10V valve 4-pipe system (sizes 3,7,11,17,25) (6) ADDITIONAL TRAY: 4Not required (Standard) 4BRV With additional tray (7) SERIAL PORT: 4Not required (Standard) 4SP1 RS485 remote communication serial port ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 HID-E1 3-speed selector + on/off for wall mounting HID-E2 Simplified room control E/I+3V+on/off for wall mounting HID-E3 Multi-function room control for wall mounting HID-E4 Multi-function room control for 0-10V valves Minimum hot water temperature thermostat Remote air sensor for HID-E2, HID-E3 and HID-E4 Control device for several units with single room control HID-T2 electronic room control HID-TI2 flush-mounted electronic ambient control HID-T3 electronic room control with humidity sensor RS485 remote communication serial port 2-pipe water balancing kit = ball valve+balancing valve 4-pipe water balancing kit = 2 ball valves + 2 balancing valves (sizes 3-7-11-17-25) 2-way ON/OFF valve kit for 2-pipe systems 3-way ON/OFF valve kit for 2-pipe systems 3-way 0-10V valve kit for 2-pipe systems Manual fresh air dampe On/off motorized fresh air outlet damper ELFOSpace OUT-V only: ■ 4 HID-F1 Control mounted on unit: 3 speed selector + off ■ 4 HID-F2 Control mounted on unit: BULB thermostat (3 speed.+off+E/ l+Temp.selection) ■ 4 HID-F4 Control mounted on unit: BULB thermostat + minimum thermostat ■ 4 Additional condensate collecting tray for vertical installation ■ 4 Supporting feet with cladding for cased vertical units h=90mm ■ 4 Supporting feet with cladding for cased vertical units h=155mm ■ 4 Supporting feet with cladding h=155mm and intake grille for cased vertical units ■ 4 Rear decor panel for cased vertical units without supporting feet ■ 4 Rear decor panel for cased vertical units with supporting feet h=90mm ■ 4 Rear decor panel for cased vertical units with supporting feet h=155mm ELFOSpace OUT-H only: ■ 4 Additional condensate collecting tray for horizontal installation (fittings to right) ■ 4 Additional condensate collecting tray for horizontal installation (fittings to left) Key to symbols: ■ Accessories supplied separately. technical data Sizes 4 Cooling capacity Sensible cooling capacity Total input 4 Heating capacity Air flow rate (max. speed) Fan type Sound pressure level (min-med-max) Power supply (1) (1) (2) (3) (4) 3 1,51 1,18 0,05 3,65 97,2 kW kW kW kW l/s dB(A) V/Ph/Hz 5 1,96 1,43 0,05 4,24 100 34 - 40 - 44 7 2,54 1,89 0,07 5,51 120 9 3,03 2,14 0,07 6,08 124 11 3,73 2,71 0,09 7,74 180 15 4,21 3,02 0,09 8,69 185 17 5,49 4,00 0,12 11,5 271 CFG 35 - 42 - 47 230/1/50 35 - 41 - 46 21 6,37 4,49 0,12 12,7 279 25 7,44 5,13 0,14 14,3 398 38 - 44 - 49 31 9,03 6,16 0,14 17,1 409 42 - 49 - 54 Data referred to the following conditions: (1) (2) Ambient air temperature: 27°C; 50% R.H. - Temp. water at inlet 7°C, temp. water at outlet 12°C - Max. speed (nominal). Ambient air temperature: 20°C - Inlet water temperature 70°C, outlet water temperature 60°C - Max. speed (nominal). (3) (4) CFG = centrifugal fan Sound pressure in free field at a distance of 1 m. Values calculated from sound power measured in echo chamber to ISO 3741 - ISO 3742 dimensions and clearances ELFOSpace OUT-H B C1 leave free A2 C C A A1 C1 leave free B B1 A Sizes Length (A) Width (B) Height (C) 4(A1) (A2) (B1) (C1) Weight in oper. mm mm mm mm mm mm mm kg 3 670 220 470 20 20 250 90 14 5 670 220 470 20 20 250 90 14 7 870 220 470 20 20 250 90 16 9 870 220 470 20 20 250 90 17 11 1070 220 470 20 20 250 90 23 15 1070 220 470 20 20 250 90 24 17 1270 220 470 20 20 250 90 26 21 1270 220 470 20 20 250 90 28 25 1470 220 470 20 20 250 90 30 31 1470 220 470 20 20 250 90 32 The above data refer to standard units. A2 A1 ELFOSpace OUT-V CAUTION! For trouble-free operation of the unit it is essential to maintain the clearances in green. 129 HYDRONIC accessories ELFOSPACE IN-V e IN-H 3÷31 Water terminal unit Uncased vertical and horizontal indoor installation Capacity from 1,5 to 9 kW ELFOSPACE ELFOSpace IN is the uncased water terminal for use in the commercial sector. The available controls are designed to satisfy the most varied of requirements, with top-of-the-range electronic control designed for connection to the ELFOControl or general supervisors. Low noise operation and easy to maintain. These are the concepts behind the development of ELFOSpace, the last generation room terminal unit that is ideal for any installation. Ten sizes available with an almost countless number of accessories for resolving any service application requirement. The ELFOSpace IN-V series has been designed specifically for uncased vertical installation and the ELFOSpace IN-H series for uncased horizontal installation. HYDRONIC IN-H IN-V functions and features H 2O Heating-Cooling Indoor inst. Uncased vertical inst. (IN-V) Uncased horizontal inst. (IN-H) Refrig. Water ELFOControl available configurations References for position of fittings: - vertical fan coils: right and left defined by standing in front of the appliance; - horizontal fan coils: right and left defined by standing in the airflow (with the air blowing on your face). Necessary configuration strings for supplying the unit with the indicated elements/accessories already mounted on the appliance. Certain accessories may also be supplied separately, as indicated in the “accessories supplied separately” list. (1) (2) (3) ELFOSPACE IN-H 3 R3 TR (1) AIR RETURN: 4R3 Return from below (Standard) 4RP Rear return (2) CONTROLS: 4TR Fan terminal block (Standard) 4TRM Terminal block with minimum safety thermostat 4CTS Clivet.Talk.Terminal Space electronics 4CTR Clivet.Talk.Terminal Room (3) WATER COIL / ELECTRIC HEATER: 4Not required (Standard) 4B14T 1-row additional coil for 4-pipe syst. (sizes 3,7,11,17,25) 4RE With electric heater (4) WATER FITTINGS: 4SX Left-hand fittings (Standard) 4DX Right-hand fittings (5) VALVES: 4Not required (Standard) (1) (2) (3) ELFOSPACE IN-V 3 MS R3 TR (1) AIR SUPPLY: 4MS Standard supply 4MR 90° supply (2) AIR RETURN: 4R3 Return from below (Standard) 4RF Front return (3) CONTROLS: 4TR Fan terminal block (Standard) 4TRM Terminal block with minimum safety thermostat 4HID-F1 3-speed selector + on/off 4HID-F2 Bulb thermostat 4HID-F3 Bulb thermostat with remote S/W 4HID-F4 Bulb thermostat with minimum safety thermostat 4HID-F5 Bulb thermostat with electric heater control 4HID-F6 Electronic multifunction room thermostat 4CTS Clivet.Talk.Terminal Space electronics 4CTR Clivet.Talk.Terminal Room (4) WATER COIL / ELECTRIC HEATER: 4Not required (Standard) 4B14T 1-row additional coil for 4-pipe syst. (sizes 3,7,11,17,25) 130 (4) SX (5) (6) (7) 4KBI2 2-pipe system water balancing kit 42V2 2-way on/off valve 2-pipe system 43V2 3-way on/off valve 2-pipe system 410V2 3-way 0-10V valve 2-pipe system 4KBI4 4-pipe system water balancing kit (sizes 3,7,11,17,25) 42V4 2-way on/off valve 4-pipe system (sizes 3,7,11,17,25) 43V4 3-way on/off valve 4-pipe system (sizes 3,7,11,17,25) 410V4 3-way 0-10V valve 4-pipe system (sizes 3,7,11,17,25) (6) ADDITIONAL TRAY: 4Not required (Standard) 4BRODX With additional tray r.h. water fittings 4BROSX With additional tray l.h. water fittings (7) SERIAL PORT: 4Not required (Standard) 4SP1 RS485 remote communication serial port (4) (5) (5) (6) (7) (8) (6) (7) (8) SX 4RE With electric heater WATER FITTINGS: 4SX Left-hand fittings (Standard) 4DX Right-hand fittings VALVES: 4Not required (Standard) 4KBI2 2-pipe system water balancing kit 42V2 2-way on/off valve 2-pipe system 43V2 3-way on/off valve 2-pipe system 410V2 3-way 0-10V valve 2-pipe system 4KBI4 4-pipe system water balancing kit (sizes 3,7,11,17,25) 42V4 2-way on/off valve 4-pipe system (sizes 3,7,11,17,25) 43V4 3-way on/off valve 4-pipe system (sizes 3,7,11,17,25) 410V4 3-way 0-10V valve 4-pipe system (sizes 3,7,11,17,25) ADDITIONAL TRAY: 4Not required (Standard) 4BRV With additional tray SERIAL PORT: 4Not required (Standard) 4SP1 RS485 remote communication serial port accessories ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 HID-E1 3-speed selector + on/off for wall mounting HID-E2 Simplified room control E/I+3V+on/off for wall mounting HID-E3 Multi-function room control for wall mounting HID-E4 Multi-function room control for 0-10V valves Minimum hot water temperature thermostat Remote air sensor for HID-E2, HID-E3 and HID-E4 Control device for several units with single room control HID-T2 electronic room control HID-TI2 flush-mounted electronic ambient control HID-T3 electronic room control with humidity sensor RS485 remote communication serial port 2-pipe water balancing kit = ball valve+balancing valve 2-way ON/OFF valve kit for 2-pipe systems 3-way ON/OFF valve kit for 2-pipe systems 3-way 0-10V valve kit for 2-pipe systems 4-pipe water balancing kit = 2 ball valves + 2 balancing valves (sizes 3-7-11-17-25) Sub-frame in galvanised sheet metal Pre-painted panel with supply and return grilles Manual fresh air damper for vert. and horiz. installation Motorized ON/OFF fresh air outlet damper Straight air supply plenum Straight air intake plenum 90° air supply plenum 90° air intake plenum Telescopic extension 0-100 mm (suitable for connection to any plenum) Air distribution duct with flexible joint Air return duct with flexible joint ■ 4 Air supply plenum with round fittings + thermal and acoustic insulating lining ■ 4 Air intake plenum with round fittings and air filter ■ 4 Terminal plenum with circular connections ■ 4 Air supply grille without air filter (suitable for connection to any plenum) ■ 4 Aluminium air supply grille without air filter ■ 4 Air intake grille with air filter (suitable for connection to any plenum) ■ 4 Aluminium air intake grille with air filter ELFOSpace IN-V only: ■ 4 HID-F1 Control mounted on unit: 3 speed selector + off ■ 4 HID-F2 Control mounted on unit: BULB thermostat (3 speed.+off+E/ l+Temp.selection) ■ 4 HID-F4 Control mounted on unit: BULB thermostat + minimum thermostat ■ 4 Additional condensate collecting tray for vertical installation ■ 4 Supporting feet for uncased vertical units h=90mm ■ 4 Supporting feet for uncased vertical units h=155mm ELFOSpace IN-H only: ■ 4 Additional condensate collecting tray for horizontal installation (fittings to right) ■ 4 Additional condensate collecting tray for horizontal installation (fittings to left) ■ 4 ■ 4 Key to symbols: ■ Accessories supplied separately. technical data Sizes 4 Cooling capacity Sensible cooling capacity Total input 4 Heating capacity Air flow rate (max. speed) Max. working static pressure Fan type Sound pressure level (min-med-max) Power supply 3 1,51 1,18 0,045 1,78 97,2 40 (1) kW (1) kW kW (2) kW (3) l/s (4) Pa (5) (6) dB(A) V/Ph/Hz 5 1,96 1,43 0,045 2,09 100 40 34 - 40 - 44 7 2,54 1,89 0,065 2,72 120 40 9 3,03 2,14 0,065 3,01 124 40 35 - 41 - 46 11 15 3,73 4,21 2,71 3,02 0,085 0,085 3,83 4,29 180 185 60 60 CFG 35 - 42 - 47 230/1/50 17 5,49 4,00 0,12 5,67 271 60 21 6,37 4,49 0,12 6,29 279 60 25 7,44 5,13 0,14 7,08 398 60 38 - 44 - 49 31 9,03 6,16 0,140 8,47 409 60 42 - 49 - 54 Data referred to the following conditions: (1) (2) (3) Ambient air temperature: 27°C; 50% R.H. - Temp. water at inlet 7°C, temp. water at outlet 12°C - Max. speed (nominal). Ambient air temperature: 20°C - Inlet water temperature 45°C, outlet water temperature 40°C - Max. speed (nominal). Air flow rate at maximum speed with available head of 0 Pa (4) (5) (6) Working static pressure at fan maximum speed CFG = centrifugal fan Sound pressure in free field at a distance of 1 m. Values calculated from sound power measured in echo chamber to ISO 3741 - ISO 3742 dimensions and clearances ELFOSpace IN-H B C1 A2 C A1 C D C1 A2 B A B1 Sizes IN-V Length (A) IN-H Length (A) Width (B) Height (C) 4(A1) (*) (A2) (**) (B1) (C1) Weight in oper. mm mm mm mm mm mm mm mm kg 3 450 545 215 450 200 100 250 90 14 5 450 545 215 450 200 100 250 90 14 7 650 745 215 450 200 100 250 90 16 9 650 745 215 450 200 100 250 90 17 11 850 945 215 450 200 100 250 90 23 15 850 945 215 450 200 100 250 90 24 17 1050 1145 215 450 200 100 250 90 26 21 1050 1145 215 450 200 100 250 90 28 25 1250 1345 215 450 200 100 250 90 30 31 1250 1345 215 450 200 100 250 90 32 The above data refer to standard units. (*) water fittings side (**) elect. supply side A1 ELFOSpace IN-V CAUTION! For trouble-free operation of the unit it is essential to maintain the clearances in green. 131 HYDRONIC ■ 4 ELFOSPACE BOX2 7÷41 Water terminal unit Cassette-type indoor installation Capacity from 2,68 to 11 kW HYDRONIC ELFOSPACE The ELFOSpace BOX2 terminal unit has been designed for installation in suspended ceilings without requiring any extra part for operation. The unit has an intake grille and four-way outlet with adjustable diffuser flaps for changing airflow direction. The ELFOSpace BOX2 is therefore suited for use in environments such as shops, restaurants, hotels and gyms, where the excellent outflowing air control makes them ideal air-conditioning units: 4available in version for 2 and 4-pipe systems; 4available in electro-mechanical or electronic version with set-up for connection to ELFOControl or general supervisors; 4possibility of controlling several units from a single point; 4suited for installation in standard suspended ceilings with 600 x 600 mm module; 4the unit comes with a condensate drain pump (500 mm vertical). functions and features H 2O Heating-Cooling Indoor inst. Uncased horizontal inst. Refrig. Water ELFOControl available configurations ELFOSPACE BOX2 7 (1) (2) (3) (4) (5) 230M CC2 - - - (1) SUPPLY VOLTAGE: 4230M 230/1/50 (Standard) (2) COIL CONFIGURATION: 4CC2 Coil configuration with 2-pipe system (Standard) 4CC4 Coil configuration with 4-pipe system (sizes 7,11,21,31) (3) HEATING ELECTRIC HEATERS: 4Not required (Standard) 4RE Heating elctric heaters (4) ELECTRONIC VERSION: 4Not required (Standard) 4CTS Clivet.Talk.Terminal Space electronics 132 (5) SERIAL PORT: 4Not required (Standard) 4SP1 RS485 remote communication serial port accessories ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 HID-E2 Simplified room control E/I+3V+on/off for wall mounting HID-E3 Multi-function room control for wall mounting Remote air sensor for electromechanical thermostats Control device for several units with single room control HID-T2 electronic room control HID-TI2 flush-mounted electronic ambient control HID-T3 electronic room control with humidity sensor RS485 remote communication serial port ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 3-way ON/OFF valve kit for 2-pipe systems 3-way ON/OFF valve kit for 4-pipe systems (sizes 7,11,21,31) Connection for fresh air intake Connection for additional air supply Fairing for uncased installation Key to symbols: HYDRONIC ■ Accessories supplied separately. technical data Sizes ELFOSpace BOX-2T (2-pipe system) 4 Cooling capacity Sensible cooling capacity Total input 4 Heating capacity Air flow rate (max. speed) Water flow rate Fan type Sound pressure level (min-med-max) Power supply (1) (1) (2) (3) (4) kW kW kW kW l/s l/s dB(A) V/Ph/Hz 7 11 15 21 31 41 2,84 2,04 0,044 3,10 144 0,13 4,62 3,22 0,068 5,12 197 0,21 5,38 3,80 0,09 5,86 244 0,24 6,58 4,60 0,077 7,26 317 0,29 10,1 7,00 0,12 11,1 417 0,45 11,9 8,30 0,17 13,2 506 0,53 24/31/36 24/36/44 25/31/44 25/39/49 RAD 32/40/50 24/31/39 230/1/50 Data referred to the following conditions: (1) (2) (3) Ambient air at 27°C; 50% R.H.; water at inlet 7°C and outlet 12°C Ambient air at 20°C; water at inlet 50°C and outlet 40°C RAD = radial-blade fan Sizes ELFOSpace BOX-4T (4-pipe system) 4 Cooling capacity Sensible cooling capacity Total input 4 Heating capacity Air flow rate (max. speed) Fan type Sound pressure level (min-med-max) Power supply (1) (1) (2) (3) (4) kW kW kW kW l/s dB(A) V/Ph/Hz (4) Sound levels refer to units with full load under nominal test conditions. The sound pressure is measured at 1 m from the external surface of the unit in open field conditions. 7 11 15 21 31 41 2,89 2,05 0,044 3,46 144 4,21 2,96 0,068 3,35 197 4,83 3,44 0,09 3,79 244 6,76 4,72 0,077 9,10 317 9,37 6,57 0,12 8,56 417 10,8 7,69 0,17 9,80 506 24/31/36 24/36/44 25/31/44 25/39/49 RAD 32/40/50 24/31/39 230/1/50 Data referred to the following conditions: (1) (2) (3) Ambient air at 27°C/19,5°C W.B.; water at inlet 7°C and outlet 12°C Ambient air at 20°C D.B.; water at inlet 50°C and outlet 40°C RAD = radial-blade fan (4) Sound levels refer to units with full load under nominal test conditions. The sound pressure is measured at 1 m from the external surface of the unit in open field conditions. dimensions and clearances B2 C B A1 A B1 A2 F D CAUTION! E For trouble-free operation of the unit it is essential to maintain the clearances in green. Sizes ELFOSpace BOX2 Indoor unit length (A) Indoor unit width (B) Indoor unit height (C) Front panel length (D) Front panel width (E) Front panel height (F) 4(A1) (A2) (B1) (B2) Weight in oper. mm mm mm mm mm mm mm mm mm mm kg 7 11 15 21 31 41 572 572 296 670 670 41 500 500 100 100 27 572 572 296 670 670 41 500 500 100 100 27 572 572 296 670 670 41 500 500 100 100 27 819 819 329 965 965 59 500 500 100 100 45 819 819 329 965 965 59 500 500 100 100 45 819 819 329 965 965 59 500 500 100 100 45 The above data refer to standard units. 133 ELFOSPACE WALL ELFOSPACE HYDRONIC Water terminal unit Indoor installation, wall-mounted, cased Capacity from 1,20 to 5,30 kW 3÷17 ELFOSpace Wall is a range of cased water terminals that are cleverly designed for quick, easy and discrete installation in the space above doors or at mid-height on walls. These exceptionally low noise units also feature air flow direction control and come with all the components needed for installation and start-up (template, three-way valve and infrared remote control). functions and features H 2O Heating-Cooling Indoor inst. Cased vertical inst. Refrig. Water available configurations (1) ELFOSPACE WALL 3 230M (1) SUPPLY VOLTAGE: 4230M 230/1/50 (Standard) 134 accessories ■ 4 Electronic wall-mounting room thermostat Key to symbols: HYDRONIC ■ Accessories supplied separately. technical data Sizes 4 Cooling capacity Sensible cooling capacity 4 Heating capacity Water flow rate Air flow rate (max. speed) Fan type Sound pressure level (min-med-max) Power supply (1) (2) (3) (4) kW kW kW l/s l/s dB(A) V/Ph/Hz 3 1,51 1,13 1,63 0,07 100 5 1,71 1,26 1,80 0,08 106 7 2,05 1,56 2,33 0,1 117 37/39/43 37/39/43 9 2,51 1,82 2,64 0,12 122 TGZ 41/43/46 41/43/46 230/1/50 15 3,25 2,36 3,32 0,15 186 17 4,62 3,25 4,66 0,22 191 42/46/49 42/46/49 Data referred to the following conditions: (1) (2) (3) Ambient air 27°C/19°C W.B., inlet water 7°C and water flow-rate as in the table Ambient air 20°C/19°C D.B., water at inlet 45°C and outlet 40°C TGZ = cross-flow fan C2 C A1 C1 A A2 CAUTION! (4) Sizes Length (A) Width (B) Height (C) 4(A1) (A2) (C1) (C2) Weight in oper. Sound levels refer to units with full load under nominal test conditions. The sound pressure is measured at 1 m from the external surface of the unit in open field conditions. Values calculated from sound power measured in echo chamber to ISO 3741 - ISO 3742 mm mm mm mm mm mm mm kg 3 870 176 270 100 100 5 870 238 270 100 100 7 1030 196 320 100 100 80 12 80 13 80 14 9 1030 258 320 100 100 15 1160 198 330 100 100 17 1160 260 330 100 100 80 14,5 80 17 80 17,5 190 (*) The above data refer to standard units. (*) Overhead installation For trouble-free operation of the unit it is essential to maintain the clearances in green. 135 ELFODUCT CFD 7÷41 Water terminal unit Uncased horizontal indoor installation Ductable Capacity from 2,37 to 12,3 kW ELFODUCT HYDRONIC The ELFODuct CFD units are ideal air-treatment terminal units for installations where ducted air distribution is necessary. The units are designed for installation in suspended ceilings and are distinguished by their compactness and extremely low noise levels because they are fitted with packaged centrifugal fans, that is, every impeller has its own external rotor motor on rubber antivibration mounts. When ductwork is extensive this solution ensures that the fan impeller is not overhung and therefore produces no vibrations, which would make the environment noisy. The 7-11-15-21 sizes may be supplied in a shorter version for space saving purposes. The main features are: 4various available controls, from simple speed control through to the electronic control set-up for connection to ELFOControl or general supervisors; 4available in version for 2 and 4-pipe systems with various types of coils (3 rows, 4 rows, 2+1 rows, 2+2 rows, 3+1 rows, 3+2 rows); 4wide choice of aeraulic accessories (plenum for round ducts, intake plenum with filter); 4electric heaters; 4low and high head-pressure fans for air distribution through ductwork. functions and features H 2O Heating-Cooling Indoor inst. Uncased horizontal inst. Refrig. Water ELFOControl available configurations Necessary configuration string for supplying the unit with the indicated elements/accessories already mounted on the appliance. Certain accessories may also be supplied separately, as indicated in the “accessories supplied separately” list. ELFODUCT CFD 7 230M6 (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) VS DX 2T CW3R - DHS PO - - - - - (1) CONSTRUCTIONAL CONFIGURATION: 4VS Standard Version 4VR Lowered version (sizes 7÷21) (2) WATER FITTINGS: 4DX Right-hand fittings (Standard) 4SX Left-hand fittingss (3) COIL CONFIGURATION: 4CC2 Coil configuration with 2-pipe system (Standard) 4CC4 Coil configuration with 4-pipe system (4) WATER COIL: 4CW3R Coil 3 rows (Standard) 4CW4R Coil 4 rows 4CW21R Coil 2+1 rows 4CW22R Coil 2+2 rows 4CW31R Coil 3+1 rows 4CW32R Coil 3+2 rows (5) AUXILIARY CONDENSATE COLLECTION TRAY: 4Not required (Standard) 4CDAN For naval installations (6) SUPPLY STATIC PRESSURE: 4DHS Standard supply static pressure 4DHH Supply static pressure High 136 References for position of horizontal fan coil fittings: right and left defined by standing in the airflow (with the air blowing on your back). (7) SUPPLY PLENUM: 4PO Air supply plenum (Standard) 4POC Air delivery plenum for round ducts (8) RETURN PLENUM: 4Not required (Standard) 4PIR Soundproofed return plenum (9) AIR RETURN CONNECTION: 4Not required (Standard) 4FPR Air return plenum flange (10) ELECTRIC HEATERS: 4Not required (Standard) 4EH01 0,5 kW heating electric heaters (size 7) 4EH03 1 kW heating electric heaters (size 11) 4EH05 2 kW heating electric heaters (sizes 15-21) 4EH07 3 kW heating electric heaters (sizes 25-31) 4EH08 4 kW heating electric heaters (size 41) (11) ELECTRONIC VERSION: 4Not required (Standard) 4CTS Clivet.Talk.Terminal Space electronic for HID-T2 or HID-T3 thermostats (ELFOControl) (12) SERIAL PORT: 4Not required (Standard) 4SP1 RS485 remote communication serial port accessories ■ 4 ■ 4 ■ 4 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 3-way “on/off” type valve for 2-pipe system 3-way “on/off” type valve for 4-pipe system Additional condensate collecting tray Additional condensate collecting tray for naval installations HID-E1 3-speed selector + on/off for wall mounting HID-E2 Simplified room control E/I + 3V + on/off for wall mounting HID-E3 Multi-function room control for wall mounting HID-T2 electronic room control HID-TI2 flush-mounted electronic ambient control ■ 4 ■ 4 HID-T3 electronic room control with humidity sensor Remote ambient air temperature sensor (for thermostat HID-E2) Key to symbols: HYDRONIC ■ Accessories supplied separately. technical data Sizes 4 Cooling capacity Sensible cooling capacity Total input 4 Heating capacity Air flow rate (max. speed) Max. working static pressure Fan type Sound pressure level Power supply 7 2,37 1,82 0,07 2,27 134 70 (1) kW (1) kW kW (2) kW (3) l/s (4) Pa (5) (6) dB(A) V/Ph/Hz 11 3,09 2,29 0,07 3,35 160 15 5,26 3,87 0,13 5,61 269 21 6,46 4,68 0,15 6,69 316 25 8,47 6,06 0,20 8,57 404 31 9,21 6,72 0,22 9,67 466 80 37 39 39 41 12,3 8,94 0,30 12,7 614 90 CFG 40 230/1/50 39 42 43 Data referred to the following conditions: (1) (2) (3) (4) Ambient air temperature: 27/19,5°C W.B. - Temp. water at inlet 7°C, temp. water at outlet 12°C standard 3 row coil - Nominal air flow rate with available head of 30 Pa. Ambient air temperature: 20°C - Inlet water temperature 45°C, outlet water temperature 40°C - standard 3 row coil - Nominal air flow rate with available head of 30 Pa. Air flow rate at maximum speed with available head of 30 Pa. Maximum available working static pressure at maximum speed (5) (6) CFG = centrifugal fan The sound levels refer to units ceiling installed without false ceiling, with nominal air flow, fan supply 230V, maximum fan speed. The sound pressure level is referred at a distance of 1 m. from the unit surface. Measurement have been made with a unit with air return plenum complete with filter. dimensions and clearances Sizes Length (A) Width (B) Height (C) 4(A1) (A2) Weight in oper. C A2 mm mm mm mm mm kg 7 525 575 285 200 100 15 11 625 575 285 200 100 17 15 885 575 285 200 100 24 21 1035 575 285 200 100 30 25 1245 575 285 200 100 35 31 1365 575 285 200 100 38 41 1665 575 285 200 100 46 The above data refer to standard units. A B CAUTION! A1 For trouble-free operation of the unit it is essential to maintain the clearances in green. 137 ELFODUCT CFI 25÷71 Water terminal unit Uncased vertical indoor installation Ductable Capacity from 8,7 to 21,6 kW HYDRONIC ELFODUCT The ELFODuct CFI units are ideal air-treatment terminal units for installations where ducted air distribution is necessary. The units are designed for vertical installation in lining walls and are distinguished by their compactness and extremely low noise levels obtained thanks to internal and external insulation. The main features are: 4various available controls, from simple speed control through to the electronic control set-up for connection to ELFOControl or general supervisors; 4available in version for 2 and 4-pipe systems; 4wide choice of aeraulic accessories (plenum for round ducts); 4electric heater section with different power plus electronic power modulation control; 4high head-pressure fans for ducted air distribution. Room control HID-T2 for wall-mounted remote installation with functions of: 4 manual or automatic summer/winter selection 4 temperature setting 4 manual setting of fan speed 4 other useful functions. functions and features H 2O Heating-Cooling Indoor inst. Uncased vertical inst. Refrig. Water ELFOControl available configurations ELFODUCT CFI 25 (1) (2) (3) (4) 230M RF - - (1) SUPPLY VOLTAGE: 4230M 230/1/50 4400TN 400/3/50+N (available only with the heating electric heaters) (2) AIR RETURN: 4RF Front return (Standard) 4R3 Return from below (3) ELECTRONIC VERSION: 4Not required 4CV3FS Fan 3-speed board 4CTS Clivet.Talk.Terminal Space electronics 138 (4) SERIAL PORT: 4Not required (Standard) 4SP1 RS485 remote communication serial port accessories ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 Hot water coil with 2 rows 4,5 kW electric heaters (sizes 25÷31) 6 kW electric heaters (sizes 41÷71) 9 kW electric heaters (sizes 25÷31) 12 kW electric heaters (sizes 41÷71) HID-T2 electronic room control HID-TI2 flush-mounted electronic ambient control HID-T3 electronic room control with humidity sensor RS485 remote communication serial port Air supply plenum for round ducts ■ 4 ■ 4 ■ 4 ■ 4 HID-E1 HID-E2 HID-E3 HID-E4 Three-speed selector + ON/OFF for wall mounting Simplified room control E/I+3V+on/off for wall mounting Multi-function room control for wall mounting Multi-function room control for 0-10V valves Key to symbols: HYDRONIC ■ Accessories supplied separately. technical data Sizes 4 Cooling capacity Sensible cooling capacity Total input 4 Heating capacity Air flow rate (max. speed) Max. working static pressure Fan type Power supply (1) (1) (2) (3) (4) (5) kW kW kW kW l/s Pa V/Ph/Hz 25 8,70 6,69 0,47 9,91 502 130 31 12,7 9,71 0,61 14,4 708 140 41 15,2 11,2 0,61 16,4 738 150 CFG 230/1/50 51 18,7 14,3 0,75 21,1 1031 230 71 21,6 16,6 1,43 24,5 1237 250 Data referred to the following conditions: (1) (2) (3) Ambient air at 27°C, 50% R.H.; water at inlet 7°C and outlet 12°C Ambient air at 20°C; water at inlet 45°C and outlet 40°C Air flow rate at maximum speed with available head of 0 Pa (4) (5) Maximum available working static pressure at maximum speed CFG = centrifugal fan dimensions and clearances Sizes Length (A) Width (B) Height (C) 4(A1) (A2) (B1) Weight in oper. C mm mm mm mm mm mm kg 25 903 290 710 400 200 1000 33 31 962 315 740 400 200 1000 40 41 1202 315 740 400 200 1000 45 51 1202 365 820 400 200 1000 54 71 1202 365 930 400 200 1000 63 The above data refer to standard units. A1 A A2 CAUTION! B1 B For trouble-free operation of the unit it is essential to maintain the clearances in green. 139 ELFODUCT CF 25÷242 Water terminal unit Uncased horizontal indoor installation Ductable Capacity from 8,7 to 83,8 kW ELFODUCT HYDRONIC The ELFODuct CF units are ideal air-treatment terminal units for installations where ducted air distribution is necessary. They are designed for installation in suspended ceilings and are distinguished by their compactness and extremely low noise levels obtained thanks to both internal and external insulation. Sizes from 91 to 242 may be ceiling or floor mounted. The main features are: 4various available controls, from simple speed control through to the electronic control set-up for connection to ELFOControl or general supervisors; 4available in version for 2 and 4-pipe systems; 4wide choice of aeraulic accessories (plenum for round ducts, fresh air intake plenum); 4electric heater section with different power plus electronic power modulation control; 4high head-pressure fans for ducted air distribution. Room control HID-T2 for wall-mounted remote installation with functions of: 4 manual or automatic summer/winter selection 4 temperature setting 4 manual setting of fan speed 4 other useful functions. functions and features H 2O Heating-Cooling Indoor inst. Uncased horizontal inst. Refrig. Water ELFOControl available configurations ELFODUCT CF 25 (1) (2) (3) 230M - - CF 25÷71 unit configuration (1) SUPPLY VOLTAGE: 4230M 230/1/50 4400TN 400/3/50+N (available only with the heating electric heaters) (2) ELECTRONIC VERSION: 4Not required (1) (2) (3) (4) ELFODUCT CF 91 400T MOS CWS (1) SUPPLY VOLTAGE: 4400T 400/3/50 without neutral 4230T 230/3/50 (2) MOTOR SPECIFICATIONS: 4MOS Standard motor 4MOD Double-speed motor (3) FILTER: 4Not required (Standard) 4FCS Angular air filter section (4) WATER COIL: 4CWS Standard coil 4CW6R 6-row coil (sizes 91-121) (5) ADDITIONAL WATER COIL: 4Not required (Standard) 4CHW2 2-row additional coil for 4-pipe syst. 4CHW3 3-row additional coil for 4-pipe syst. (sizes 91-121) 140 4CV3FS Fan 3-speed board 4CTS Clivet.Talk.Terminal Space electronics (3) SERIAL PORT: 4Not required (Standard) 4SP1 RS485 remote communication serial port (5) - (6) (7) (8) CF 91÷242 unit configuration (6) ELECTRIC HEATERS: 4Not required (Standard) 4EH09 4,5 kW electric heaters (sizes 91-121) 4EH10 6 kW electric heaters (sizes 91-121) 4EH12 9 kW electric heaters (sizes 91-121) 4EH14 12 kW electric heaters (sizes 91-121) 4EH17 18 kW electric heaters 4EH20 24 kW electric heaters (sizes 142÷242) (7) ELECTRONIC VERSION: 4Not required (Standard) 4CQEP Power switchboard (Standard) 4CTS Clivet.Talk.Terminal electronics (8) SERIAL PORT: 4Not required (Standard) 4SP1 RS485 remote communication serial port accessories ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 Rubber antivibration mounts (sizes 91÷242) Hot water coil with 2 rows Hot water coil with 3 rows (sizes 91-121) 4,5 kW electric heaters (sizes 25-31-91-121) 6 kW electric heaters (sizes 41÷121 ) 9 kW electric heaters (sizes 25-31-91-121) 12 kW electric heaters (sizes 41÷121) 18 kW electric heaters (sizes 91÷242) 24 kW electric heaters (sizes 142÷242) Angular air filter section (sizes 91÷242) HID-T2 electronic room control HID-TI2 flush-mounted electronic ambient control ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 HID-T3 electronic room control with humidity sensor RS485 remote communication serial port Fresh air mixing, recirculation (sizes 25÷121) Air supply plenum for round ducts (sizes 25÷71) HID-E1 3-speed selector + on/off for wall mounting (sizes 25÷71) HID-E2 Simplified room control E/I+3V+on/off for wall mounting (sizes 25÷71) HID-E3 Multi-function room control for wall mounting (sizes 25÷71) HID-E4 Multi-function room control for 0-10V valves (sizes 25÷71) 3-way 0-10V valve kit for 2-pipe systems 3-way 0-10V valve kit for 4-pipe systems (sizes 142÷242) HYDRONIC Key to symbols: ■ Accessories supplied separately. technical data Sizes 4 Cooling capacity Sensible cooling capacity Total input 4 Heating capacity Air flow rate Max. working static pressure Max. working static pressure Fan type Sound pressure level Power supply (1) (1) (2) (3) (4) (5) (6) (7) kW kW kW kW l/s Pa Pa dB(A) V/Ph/Hz 25 8,70 6,69 0,47 9,91 502 130 - 31 12,7 9,71 0,61 14,4 708 140 - 24 55 41 15,2 11,2 0,61 16,4 738 150,0 - 51 18,7 14,3 0,75 21,1 1031 230 - 56 57 230/1/50 71 21,6 16,6 1,43 24,5 1237 250 58 91 121 29,7 40,3 22,1 29,7 0,75 1,10 32,1 43,1 1417 1889 170 160 240 240 CFG 43 50 142 46,8 33,6 1,1 47,9 2120 110 300 51 162 52,3 38,0 1,5 54,5 2500 110 300 182 58,9 42,5 1,5 61,0 2660 80 300 56 52 400/3/50 202 75,2 52,6 2,2 74,4 3100 140 300 242 83,8 59,4 3,0 84,4 3620 230 300 53 53 Data referred to the following conditions: (1) (2) (3) Ambient air at 27-19,5°C W.B.; water at inlet 7°C and outlet 12°C Ambient air at 20°C; water at inlet 45°C and outlet 40°C Air flow rate at maximum speed with available head of 0 Pa (sizes 25÷71); nominal air flow rate (sizes 91÷242). Maximum available working static pressure at maximum speed (sizes 25÷71); max available static pressure with standard motor. It does not take into consideration any accessory increasing the pressure drop on the airside (sizes 91÷242) (4) (5) (6) (7) Max available static pressure with high power motor. It does not take into consideration any accessory increasing the pressure drop on the airside (sizes 91÷242) CFG = centrifugal fan Sound levels refer to units with full load under nominal test conditions. The sound pressure is measured at 1 m from the external surface of the unit in open field conditions. dimensions and clearances 25÷71 C 91÷121 A1 C A A2 B A1 A A2 142÷242 B Sizes Length (A) Width (B) Height (C) 4(A1) (A2) Weight in oper. mm mm mm mm mm kg 25 1000 480 297 200 400 33 31 1100 500 322 200 400 33 41 1340 550 322 200 400 40 51 1340 550 372 200 400 45 71 1340 550 422 200 400 54 91 1285 945 585 200 400 138 121 1435 1030 685 200 400 158 142 2010 750 630 500 500 170 162 2010 750 630 500 500 190 182 2010 750 630 500 500 195 202 2510 850 680 500 500 253 242 2510 850 680 500 500 265 The above data refer to standard units. C A1 A A2 CAUTION! B For trouble-free operation of the unit it is essential to maintain the clearances in green. 141 ELFODUCT CF-V 31÷242 Water terminal unit Cased vertical indoor installation Ductable Capacity from 13,6 to 89 kW ELFODUCT HYDRONIC The ELFODuct CF-V tall water terminal units have been designed for installation directly in the room or in technical spaces. The units have been designed for sending air directly into the room or with ducted distribution. They are distinguished by their compactness and extremely low noise levels obtained thanks to internal soundproofing. The main features are: Room control HID-T2 for wall-mounted remote installation with functions of: 4 manual or automatic summer/winter selection 4 temperature setting 4 manual setting of fan speed 4 other useful functions. 4various available controls, from simple speed control through to the electronic control set-up for connection to ELFOControl or general supervisors; 4available in version for 2 and 4-pipe systems; 4choice of aeraulic accessories (plenum for front air supply or on three sides); 4electric heater section with different power plus electronic power modulation control; 4fans available with high static pressure, which allow extensive ducting; 4front air return through grille (standard) or with return from the floor or from the rear functions and features H 2O Heating-Cooling Indoor inst. Cased vertical inst. Refrig. Water ELFOControl available configurations ELFODUCT CF-V 31 (1) (2) (3) (4) (5) (6) 230M RF - - - - (1) SUPPLY VOLTAGE: 4230M Power supply 230/1/50 (Standard) 4400T Power supply 400/3/50without neutral (available only with the heating electric heaters) (2) AIR RETURN: 4RF Front return (Standard) 4R3 Return from below 4R4 Rear return (3) HOT WATER COIL: 4Not required (Standard) 4CHW2 2-row hot water coil (4) ELECTRIC HEATERS: 4Not required (Standard) ELFODUCT CF-V (1) (2) 91 (1) (2) (3) (4) (5) (6) (7) (8) 400T RF SM MOS - - - - SUPPLY VOLTAGE: 4400T Power supply 400/3/50 without neutral (Standard) 4230T Power supply 230/3/50 AIR RETURN: 4RF Front return (Standard) 4R3 Return from below 4R4 Rear return (3) AIR FLOW RATE: 4SM Standard supply air flow-rate 4RM Reduced outlet air flow-rate (4) MOTOR SPECIFICATIONS: 4MOS Standard motor 4MOD Double-speed motor (5) HOT WATER COIL: 4Not required (Standard) 4CHW2 2-row hot water coil 142 CF-V 31-71 unit configuration 4EH09 4,5 kW heating electric heaters 4EH10 6 kW heating electric heaters (sizes 41÷71) 4EH12 9 kW heating electric heaters 4EH14 12 kW heating electric heaters (sizes 41÷71) 4EH17 18 kW heating electric heaters (size 71) (5) ELECTRONIC VERSION: 4Not required (Standard) 4CV3FS Electronic version with 3-speed board for the fan Clivet.Talk.Terminal Space electronic for HID-T2 or HID-T3 thermostats 4CTS (ELFOControl) (6) SERIAL PORT: 4Not required (Standard) 4SP1 RS485 remote communication serial port CF-V 91-242 unit configuration (6) ELECTRIC HEATERS: 4Not required (Standard) 4EH09 4,5 kW heating electric heaters 4EH10 6 kW heating electric heaters 4EH12 9 kW heating electric heaters 4EH14 12 kW heating electric heaters 4EH17 18 kW heating electric heaters 4EH20 24 kW heating electric heaters (sizes 142÷242) (7) ELECTRONIC VERSION: 4Not required (Standard) Clivet.Talk.Terminal Space electronic for HID-T2 or HID-T3 thermostats 4CTS (ELFOControl) (8) SERIAL PORT: 4Not required (Standard) 4SP1 RS485 remote communication serial port accessories ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 ■ 4 HID-T2 electronic room control HID-TI2 flush-mounted electronic ambient control HID-T3 electronic room control with humidity sensor HID-S1 local electronic room control RS485 remote communication serial port Front air supply plenum Plenum for air supply on three sides ■ 4 ■ 4 3-way 0-10V valve kit for 2-pipe systems 3-way 0-10V valve kit for 4-pipe systems Key to symbols: HYDRONIC ■ Accessories supplied separately. technical data Sizes 4 Cooling capacity Sensible cooling capacity Total input 4 Heating capacity Air flow rate Max. working static pressure Max. working static pressure Fan type Sound pressure level Power supply (1) (1) (2) (3) (4) (5) (6) (7) kW kW kW kW l/s Pa Pa dB(A) V/Ph/Hz 31 13,6 9,82 0,30 13,1 569 85 48 41 19,1 13,7 0,30 18,1 778 93 - 51 21,6 15,7 0,50 22,6 944 80 - 49 50 230/1/50 71 27,9 20,3 0,60 26,2 1166 70 - 91 36,9 26,5 0,80 35,9 1597 140 240 51 53 101 44,0 21,8 1,10 42,3 1889 170 240 CFG 56 121 48,7 35,6 1,50 46,6 2167 180 240 142 65,5 47,1 1,50 62,0 2638 140 210 182 75,4 54,9 2,20 71,5 3194 115 240 202 83,6 60,2 2,20 78,4 3472 145 240 242 89,0 64,9 3,00 85,7 3888 180 240 58 58 400/3/50 60 62 64 Data referred to the following conditions: (1) (2) (3) (4) Ambient air 27°C/19,5°C W.B.; water at inlet 7°C; water at outlet 12°C Ambient air 20°C D.B.; water at inlet 45°C; water at outlet 40°C; R.H. 50% Standard air flow rate Available static pressure with standard flowrate, including air filter (sizes 31÷71); available static pressure with standard motor, including air filter (sizes 91÷242). (5) (6) (7) Max available static pressure with high power motor (sizes 91÷242) CFG = centrifugal fan Sound levels refer to units with full load under nominal test conditions. The sound pressure is measured at 1 m from the external surface of the unit in open field conditions. dimensions and clearances Sizes Length (A) Width (B) Height (C) 4(A1) (A2) (B2) Weight in oper. C mm mm mm mm mm mm kg 31 650 500 1700 400 400 1000 96 41 850 500 1700 400 400 1000 117 51 850 500 1700 400 400 1000 123 71 1050 500 1700 400 400 1000 140 91 1050 670 2000 400 400 1000 185 101 1250 670 2000 400 400 1000 210 121 1250 670 2000 400 400 1000 215 142 1870 670 2000 400 400 1000 250 182 1870 670 2000 400 400 1000 260 202 2070 670 2000 400 400 1000 290 242 2070 670 2000 400 400 1000 295 The above data refer to standard units. B CAUTION! A2 B2 A A1 For trouble-free operation of the unit it is essential to maintain the clearances in green. 143