LM-N Series Corrosion-resistant, rugged metal units featuring fully adjustable lighting heads, high capacity and long-life nickel-cadmium batteries. An Severe Conditions Product Line Suitable for the following environmental applications Hot Cold Universal electrical box knockout pattern — mounts boxes up to 4” square Slot in cover allows easy installation or removal, without fully backing out retaining screws Test switch Pilot light Enclosure extension captures bottom of cover securely Dimensions Features n Easy to install n Longest life, maintenance-free, Nickel-Cadmium batteries n 6- & 12-volt models n Fully adjustable, glare-free lighting heads n Lighting heads supplied top mounted; relocatable to side mounting position n Available with additional unit-mounted lighting head n Available without lighting heads for powering remote mounted fixtures n Matching remote fixtures available n White, corrosion-resistant housing and cover n 120/277VAC, 60 Hz operation standard n Keyhole universal mounting slots allow easy installation of chassis to electrical box n Low-voltage battery disconnect and transformer isolation protection n Test switch and AC-On indicator n Models operate for 90 minutes n UL 924 Listed (Emergency Lighting) F E C B D A Dimensions in inches (”) and centimeters (cm) Enclosure Style 1 2 A B C D E F 5 3/4" 111/2" 131/2" 153/4" 25" 37/8" 9.8cm 14.6cm 29.2cm 34.3cm 40.0cm 63.5cm 43/4" 7 3/4" 131/2" 153/4" 18" 271/4" 12.1cm 19.7cm 34.3cm 40.0cm 45.7cm 69.2cm LM-N Series Specifications High-Capacity Nickel-Cadmium Emergency Lighting Units Product Selector Construction Housing and Cover: Corrosion-resistant steel Lamp Housings: UL-recognized flame-rated thermoplastic Finish Color: Ceiling white Illumination Lamp type: Incandescent PAR 36 sealed beam type Lamp Voltage: 6- or 12-volt, depending on model Lamp Wattage: 7.2W Rated Lamp Life: 100 hours Photometrics (horizontal isofootcandle distribution) 6 V, 7.2W SBT Lamp 12V, 7.2W SBT Lamp Total Watts For: DC Enclosure 11/ 2 3 4 Standard 2 Models Volts Style(1) Hrs. Hrs. Hrs. Hrs. 1 15 — — — LM15N 6 LM30N 6 1 30 25 17 13 LM50N 6 1 50 42 29 22 LM50N-12V 12 2 50 42 29 22 LM100N-12V 12 2 100 85 59 46 Options (add suffix to model number) Voltmeter -V Unit supplied with three lighting heads (2) -3 Unit supplied with four lighting heads (2) -4 Unit supplied without lighting heads (2) -0 Line cord (120VAC only) -A31 Line cord (277VAC only) -A32 Accessory Items (order separately) Wire Guard (3) 40G Single matching remote lighting head (white) (4) SRHSW Twin matching remote lighting head (white) (4) SRHDW (1) Reference dimensioned illustrations on front of sheet (2) Not available for use with LM15N model (3) Wire guard for use with units having top mounted heads only (4) Specify lamp voltage and wattage when ordering. Example: SRHSW0625 Installation Unit Wall Mounting: Mounts through universal knockout pattern to standard electrical boxes up to 4” square. Also, mounts to wall surface through keyhole mounting slots. Wiring: Pre-stripped transformer leads provided. All AC connections made inside unit housing. Fused distribution board provided for connection of remote lighting fixtures Electronics Input: 120/277VAC, 60 Hz (standard) Built in-Protection: Transformer isolation and low battery voltage disconnect Charger: Fully automatic, constant voltage, current limited Transfer: Electric relay Distribution: Fused leads Battery Recharge Cycle: Per UL time standards Test Means: Integral test switch Indicators: LED AC-ON indicator Battery Type: Maintenance-free Nickel-Cadmium Operating Temperature Range Factory Certified: 0° to 30°C (32°F to 86°F) UL Listed: 20° to 30°C (68°F to 86°F) Power Consumption Maximum: 34 watts (all models) Compliances UL 924 and NFPA-101 (all models) Alternate Lamps To order alternate lamps in the unit mounted lighting heads, suffix the model number with the alternate lamp voltage and wattage. Example: LM50N 0625 Suggested Specification Construction will consist of NEMA 1 corrosion-resistant steel enclosure in ceiling white finish. Design will allow 120/277VAC, 60Hz operation standard. Total unit output capacity shall be _________ watts. Emergency illumination will be provided by two integral (6 volt) (12 volt), ___ watt incandescent PAR 36 sealed beam type lighting heads, and __V, __W remote lamps/fixtures. Units shall be designed to mount directly to wall surfaces through keyhole knockouts in the back plate. A universal knockout pattern shall be provided in the unit back plate for mounting to all standard electrical boxes up to 4” square. Emergency components will include a fully automatic, constant voltage, current limited type battery charger; a (6 volt) (12 volt) maintenance-free nickel-cadmium battery; an electric relay for transfer to emergency lighting mode; an AC-On indicator light; and a test switch. The unit charger will be capable of recharging the battery within acceptable UL time standards. Emergency operation must be provided for a minimum of ___ hours. Connections for remote lighting fixtures shall be fused. Units must comply with all UL 924 and NFPA 101 Life Safety Code requirements. Dimensions to be (____ in.) (____ cm) high by (____ in.) (____ cm) wide by (____ in.) (____ cm) deep. Specified equipment to be Dual-Lite model________________. Optional equipment will include: ________________________________________________. Warranty Unit and Electronics: 3 years full Battery: 1 years full, 9 years pro-rata (10 years total) A Hubbell Lighting, Inc. brand with representatives’ offices in principal cities throughout North America. Copyright© Dual-Lite, All Rights Reserved • Specifications subject to change without notice. • Printed in U.S.A. 0601851 7/05