Fuji 1/16 DIN Super Timers Overview FUJI 1/16 DIN SUPER TIMERS Overview The MS4S series super timers are a 1/16 DIN style timing relay designed for process control, machine tool control, safety control and many other types of applications. The timers are plug-in 8pin or 11-pin surface/DIN rail mountable with up to four selectable modes of operation and four selectable timing ranges. Features MS4SA MS4SM 1 - 80 0 - 633 - 0405 • Timing range from 0.05 seconds to 60 hours • Timer scale with selectable ranges of 0-6, 0-12, 0-30 and 0-60 • Timing units in selectable ranges of 0.1s, sec, min and hrs • LED indicators. Power on (green) flickers during timing operation UP (red) on when N.O. contact is closed • Multi-mode timer with mode indication. On-delay (PO), flicker (FL), one-shot (OS), or signal off-delay (SF) • 11-pin plug-in with start, reset and gate (interrupt) input signals and a DPDT contact output. • On-delay timer • 8-pin plug-in with a DPDT contact output • Timing range from 0.05 seconds to 60 hours • Timer scale with selectable ranges of 0-6, 0-12, 0-30 and 0-60 • Timing units in selectable ranges of 0.1s, sec, min and hrs • LED indicators — power on (green) flickers during timing operation. UP (red) on when N.O. contact is closed MS4SC • On-delay timer • 8-pin plug-in with a SPDT timed contact output and a SPDT instantaneous contact output • Timing range from 0.05 seconds to 60 hours • Timer scale with selectable ranges of 0-6, 0-12, 0-30 and 0-60 • Timing units in selectable ranges of 0.1s, sec, min and hrs • LED indicators — power on (green) flickers during timing operation. UP (red) on when N.O. contact is closed Product Selection Guide Part Number Description MS4SM-AP-ADC Multi-mode timer with selectable timing range from 0.05s to 60 hours. Input power is 100 - 240 VAC. DPDT relay output. 11-pin connection. UL, CSA , TÜV approved Voltage MS4SA-AP-ADC On-delay timer with selectable timing range from 0.05s to 60 hours. Input power is 100 - 240 VAC. DPDT relay output. 8-pin connection. UL, CSA, TÜV approved MS4SC-AP-ADC On-delay timer with selectable timing range from 0.05s to 60 hours. Input power is 100 - 240 VAC. SPDT timed relay output and SPDT instantaneous relay output. 8-pin connection. UL, CSA, TÜV approved 0.05 seconds to 60 hours MS4SM-CE-ADC Multi-mode timer with selectable timing range from 0.05s to 60 hours. Input power is 24 VDC/ VAC DPDT relay output. 11-pin connection. UL, CSA , TÜV approved 0.05 seconds to 60 hours MS4SA-CE-ADC On-delay timer with selectable timing range from 0.05s to 60 hours. Input power is 24 VDC/ VAC. DPDT relay out24 VDC/VAC put. 8-pin connection. UL, CSA, TÜV approved 0.05 seconds to 60 hours MS4SC-CE-ADC On-delay timer with selectable timing range from 0.05s to 60 hours. Input power is 24 VDC/ VAC. SPDT timed relay output and SPDT instantaneous relay output. 8-pin connection. UL, CSA, TÜV approved 0.05 seconds to 60 hours TP411X Surface mount socket for MS4SM series timers. UL, CSA, TÜV approved TP411SBA Flush mount socket for MS4SM series timers. UL, CSA, TÜV approved TP48X Surface mount socket for MS4SA and MS4SC series timers. UL, CSA, TÜV approved TP48SBA Flush mount Socket for MS4SA and MS4SC series timers. UL, CSA, TÜV approved SPDT N.C. C DPDT N.O. 0.05 seconds to 60 hours 100-240VAC N/A C Time Range 0.05 seconds to 60 hours N/A N.O. N.C. C N.C . N.O N.C. A single pole, double throw relay switches one common line between two stationary contacts, one normally open and one normally closed. 1090 Process Control A double pole, double throw relay simultaneously switches two independent commons with two independent normally open/normally closed contacts. Fuji 1/16 DIN Super Timers Specifications FUJI 1/16 DIN SUPER TIMERS P ROCESS MS4SM-AP-ADC MS4SM-CE-ADC MS4SC-AP-ADC MS4SC-CE-ADC TP48SBA TP48X TP411X TP411SBA Specifications Approvals Repeat Accuracy Reset Time UL file no.: E44592, CSA file no.: LR20479, TÜV license no: R9551800 ±0.3% at maximum setting time 0.1 second or less 85-264VAC 20.4-26.4VDC/VAC Operating Voltage Range MS4SM-AP-ADC MS4SA-AP-ADC MS4SC-AP-ADC MS4SM-CE-ADC MS4SA-CE-ADC MS4SC-CE-ADC Operating Temperature Range Humidity Contact Ratings Power Consumption Insulation Resistance -10 to +55°C (14 to 131°F) (no icing) Dielectric Strength Vibration 35 to 85% (no condensation) 5A at 30VDC resistive load, 1A @ 30VDC inductive load, 5A @ 250VAC resistive load, 2.5A @ 120VAC inductive load Approx. 10VA at120/240VAC; 1W at 24VDC 100M⏲ at 500 VDC insulation tested 2000VAC 1 min. between current carrying part and non-current carrying part 2000VAC 1 min. between output contact and control circuit 1000VAC 1 min. between open contacts Malfunction durability: 10 to 55Hz, 0.5mm double amplitude Mechanical durability: 10 to 55Hz, 0.75mm double amplitude Life Expectancy Malfunction durability: 100m/s2 Mechanical durability: 500m/s2 Mechanical: 20 million operations Electrical: 100,000 operations at 250VAC 5A resistive load Weight Approx. 100g (3.527 oz.) Shock w w w. a u to m at i o n d i re c t . c o m / t i m e rs MS4SA-AP-ADC MS4SA-CE-ADC Process Control 1091 Fuji 1/16 DIN Super Timers Specifications FUJI 1/16 DIN TIMERS TIMING AND WIRING DIAGRAMS Timing and wiring diagrams 6 5 MS4SM 7 4 Reset signal 1. On-delay PO Start signal Gate signal 8 3 9 2 Signal start (- ) Power on start T T 1 10 11 (+) Power T Power 2-10 쐌 With power off turn the mode selector until PO is displayed. 쐌 When power is on, applying the start signal turns the timed N.O. normally open) contact on after the set time has elapsed. 쐌 When using a power-on start, pins 2 and 6 (start signal) must be jumpered together Start signal 2-6 Reset signal 2-7 Timed NC 1-4 11-8 Timed NO 1-3 11-9 Indicator POWER Indicator OUTPUT 2. Flicker FL T-a T T T T 쐌 With power off, turn the mode selector until FL is displayed. 쐌 When power is on, applying the start signal turns the timed contact on and off repeatedly at the set time intervals. Power 2-10 Start signal 2-6 Reset signal 2-7 1 - 80 0 - 633 - 0405 Timed NC 1-4 11-8 Timed NO 1-3 11-9 Indicator POWER Indicator OUTPUT 3. One-shot OS T T-a T 쐌 With power off, turn the mode selector until OS is displayed. 쐌 When power is on, applying the start signal instantly turns the timed N.O. contact on and turns it off after the set time has elapsed. T-a Power 2-10 Start signal 2-6 Reset signal 2-7 Timed NC 1-4 11-8 Timed NO 1-3 11-9 Indicator POWER Indicator OUTPUT 4. Signal off-delay SF T-a T-a 쐌 With power off, turn the mode selector until SF is displayed. 쐌 When power is on, applying the start signal instantly turns the timed N.O. contact on. Removing the start signal turns the contact off after the set time has elapsed. T-a T Power 2-10 Start signal 2-6 Reset signal 2-7 Timed NC 1-4 11-8 Timed NO 1-3 11-9 Notes: 1. T= set time. t = time period within set time. 2. The gate signal is used to interrupt the timing operation. Indicator POWER Indicator OUTPUT MS4SA On-delay Power 2-7 Timed NO 1-3 8-6 Timed NC 1-4 8-5 NC NO T 6 3 (Ð) 2 COM NC 5 4 1 8 NO 7 (+) COM 쐌 When power is applied, the timed N.O. contacts make after the set time has elapsed. 쐌 When power is removed, the contacts reset. Power MS4SC On-delay Power NC 2-7 T Timed NO 8-6 Timed NC 8-5 Inst. NO 1-3 Inst. NC 1-4 N 1092 Process Control NO 4 6 3 (Ð) 2 COM NC 5 1 8 Power NO 7 (+) COM 쐌 Timed contact When power is applied, the N.O. contact makes after the set time has elapsed. When power is removed, the contacts reset. 쐌 Instantaneous contact When power is applied, the N.O. contact makes instantly. When power is removed, the contacts reset. Fuji 1/16 DIN Super Timers Specifications FUJI 1/16 DIN SUPER TIMERS DIMENSIONS Side View Side View MS4SA and MS4SA andMS4SC MS4SC MS4SM MS4SM 48 15 48 66.5 52.3 14.2 44.5 39 48 P ROCESS 48 6 Wt : Approx. 100g (3.53oz) Sockets for MS4SA, MS4SC (8-pin) Socket for for MS4SA, MS4SC (8-pin) (8-pin) Socket MS4SA, MS4SC TP48SBA TP48X Terminal M3.5x8 38.4 18.8 4 3 Terminal M3.5x7 3 4 5 6 40 0.2 45 5 All dimensions in mm 5.5 70 6 Dia. 27 14 35.4 TP48X 2-Diam 4.5 2 1 8 7 7 8 1 Mounting hole 2- Diam. 4.5 45 4 7.8 2 5 7 17 50 Mass : Approx. 40g 20.3 or less Wt: Approx. 50g (1.76oz) Selection of operation mode/MS4SM 24.5 2-Diam 4.5 Dia. 27 5.5 Terminal M3.5x7 9 10 11 3 1 2 50 0.2 Mounting hole 2 - Diam. 4.5 5 4.5 17.5 5 45 Connection of p 7 Mass : Approx. 45g 31.2 or less Wt: Approx. 70g (2.47oz) 2 1 11 7 6 4 3 8 9 10 4 7.8 40 45 6 5 4 7 70 8 Terminal M3.5x8 26.8 38.4 18.8 35.4 TP411X TP411X Selection of tim Sockets for MS4SM (11-pin) Sockets for MS4SM (11-pin) TP411SBA Socket MS4SM (11-pin) Socketforfor MS4SM (11-pin) w w w. a u to m at i o n d i re c t . c o m / t i m e rs Dimensions in mm Using the super timer Operation mode indication window Power ON indicator (Green) Operation mode selector Timing range selector Output indicator (Red) Time unit selector Process Control 1093