UL Lighting Operations Burago, Italy Safety is evolving. So is UL. Opened in May of 2012, this Centre of Excellence is entirely dedicated to safe, energy efficient lighting technologies. Located in Milan, the facility acts as a hub for all of Europe and covers an area of 3,000 square meters. The lab offers high-tech capabilities, content and over thirty engineers highly trained and skilled in lighting technologies including 360° SSL (Solid State Lighting). The space offers local services and technical support for Italian and European manufacturers to better compete in the global market without sacrificing safety, quality or performance. The Centre of Excellence provides solutions for the entire lighting industry supply chain; from distributors of electrical materials, to manufacturers, architects, designers and even software companies. Expert staff, precise measurements and outstanding customer service at this state-of-the-art facility result in quicker time to market, reduced internal costs and increased consumer confidence. Safety is evolving. So is UL Italy, providing solutions as you develop new technology and navigate compliance, regulatory and trade challenges. • ENERGY STAR® • Designlights™ Consortium (DLC) • Lighting Facts® • European Energy Efficiency • Natural Resources Canada (NRCan) • Chinese Energy Efficiency • California Energy Commission (CEC) • Brazilian Energy Efficiency State-of-the-art Facility Italy is one of the most important European markets, featuring many small and medium sized enterprises. A first-of-its-kind in Europe, the 3,000 square meter laboratory is equipped with cutting-edge equipment and instrumentation. Photometric tests • Three high speed mirror goniophotometers with colorimeter EuP directive requirements Safety Testing for all sources of lighting CBTL Laboratory fully equipped for electrical safety testing intended to obtain access to the global market: • LED – OLED – HID – Fluorescent Market Related Certification Mark North America cULus Europe ENEC15 CB scheme (54 member countries) China CCC Japan PSE Australia RCM mark India ISI mark • Lighting products and their corresponding components (modules, optics, electronic parts) • Ballast, led drivers, holders Interoperability Zhaga authorized laboratory Performance INMETRO • Three high speed mirror goniophotometer • Three integrating spheres; one 50 cm diameter; one 165 cm diameter; two 200 cm diameter • Three lamp life test racks holding 100 lamps each to test LED, CFLs single ended, HID and incandescent lamps • Test equipment to measure UV emission of certain light sources ZHAGA • Lifetime of the product • Test equipment to verify LED sources and luminaires in accordance with the books published • European photometric testing (EN 13032 / UNI 11356) • Gauges for interchangeability test of LLEs and holders • American photometric testing (LM 70, LM 80) • Two chillers to test LLEs on the cooling tower and on the required heat sink • Noise • Color temperature • Color Rendering Brazil Following accreditation, the laboratory will be able to offer certifications to the following programs for energy efficiency: • Three integrating spheres; one 50 cm diam; one 165 cm diam; two 200 cm diam CAPABILITIES IECEE Energy Efficiency • Photobiological Testing — Double monocromator for photobiological test on all light sources in the range 200-3000 nm, a requirement for LED sources • Power supplies, ballast lifetimes • Force transducer for insertion / removal of LED light sources NA energy saving requirements ENERGY STAR,® DLC and Lighting Facts® • Three lamp life test racks holding 100 lamps each to test LED, CFLs single ended, HID and incandescent lamps • Halo test for elevated ambient temperature test • Test enclosure for lamp life test up to 45 °C • Buel & Kiaer Noise measurement test equipment Safety • Endurance test chamber ta+10 °C • Temperature test chamber, up to 45 °C • Instruments and test equipment to test almost all the luminaires in accordance with the IEC 60598 series • Instruments and test equipment to test almost all the electronic control gears and LED modules in accordance with the IEC 61347 series • Instruments and test equipment to test LED modules IEC EN 62031 • Instruments and test equipment to verify performance requirements of control gears, a requirement for the ENEC certification • IP Test equipment, up to IP 68 • CCD camera for specific luminance measurements Environmental • 3D measuring equipment for dimensional measurement • Climatic chamber -40 / 180 °C with ramp up to 15 K / min • Integrating sphere, 50 cm diam • Salt fog test ACCREDITATIONS UL is accredited to offer the most recognized international programs, facilitating Italian and European businesses access to the global market in accordance with current U.S. and International regulations. NVLAP ISO 17025 eventually applicable National deviation to the IEC standards, UL provides full support from start to finish with the issuance of National Certification through our Global Market Access team. Accreditation is essential to access energy saving certification programs on lighting products, including Energy Star, DLC and Lighting facts. ENEC • UL is also accredited 17025 by IAS, a member of international certification scheme ILAC, for the European Standard for photometry and national standard UNI 11356 ENEC to issue ENEC 15 mark on the same lighting categories that are CBTL accredited. ENEC means safety in Europe, and all signatories of the ENEC Mark Scheme actively support its commitment to the highest safety levels. • Thanks to our comprehensive test equipment and turnaround time of five days, UL can assist manufacturers in getting their product rapidly tested IECEE CBTL IECEE CBTL for most of the IEC standards for Luminaires and components for lighting products. CB certification is the key for market access to the national certification. More than one hundred countries in the world adhered to the CB scheme. • By acquiring the right to use the ENEC mark you avoid the multiple testing and certification of devices, thus saving time and money • The mark also enables you to export your products with ease to at least 25 European countries UL can assist clients to get CB and ENEC certification with a turnaround time of 4 weeks. • Through the CB Test Report and CB Certificate issued by our NCB UL International Demko, including the Global Solutions UL is home to five, global state-of-the-art performance and energy efficiency verification labs. Offering a high level of technical expertise and one of the fastest turn-around times in the industry, UL is the one-stop shop for your energy efficiency and performance verification needs. With expanded testing capabilities and capacity for onsite training programs, these labs provide manufacturers with comprehensive solutions to help them stay competitive and be better prepared to address the various performance requirements and energy-efficiency verification programs. Allentown, PA Scottsdale, AZ UL Via XXV Aprile, 3B 20875 Burago di Molgora MB, Italy T: +39.039.6385801 F: +39.039.6385865 ul.com UL and the UL logo are trademarks of UL LLC © 2012. BDI 21103.2 Burago, Italy Manesar, India Nansha, China