High Speed Fuses Ferrule Fuses Table of Contents Basic Catalog Number FWA FWX FWH FWC FWP FWK FWJ FWL/FWS Volts 150 250 500 600 690V/700 750 1000 1250/1500/2000 Amp Range 5-60 1-50 0.25-30 6-32 1-100 5-60 20-30 2-30 General Information Page 224-225 226-227 228-231 232-233 234-237 238-239 240-241 242 Accessories Fuse Holders Bussmann offers a full line of ferrule style (cylindrical clip-mounted) fuses, designed and tested to meet standards and requirements in various locations around the world. Their unique design and construction provide: • Superior cycling capability • Low energy let-through (I2t) Ferrule fuses provide an excellent solution for small UPS, small ac drives and other low power applications where space is at a premium. 241 Voltage Rating Ferrule Fuse Ranges Amps 5-60 1-50 0.25-30 6-32 20-100 1-50 5-60 20-30 20-30 8-15 2-6 AC X X X X X X X X X X X DC X X X X — X X X (800Vdc) X (1000Vdc) X (1000Vdc) X (1000Vdc) All Bussmann ferrule fuses — except 690V — have been tested at their rated voltage. The 690V ferrule fuse has been tested to the IEC 60269 standard, which requires clearing at the rated voltage +5%. Accessories Ferrule fuses may be mounted in fuseclips, fuse holders, fuse blocks or fused switches. A variety of products are available. Please consult Bussmann Application Engineering to discuss your requirement. For product data sheets, visit www.cooperbussmann.com/DatasheetsEle 223 High Speed Fuses Volts 150 250 500 600 700 (22 x 58mm) 700 (14 x 51mm) 750 1000 1250 1500 2000 High Speed Fuses Ferrule — FWP 690V/700V (IEC/UL): 20-100A, Striker Optional FWP (22 x 58mm) Arc Voltage This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of theapplied working voltage, Eg, (rms) at a power factor of 15%. Specifications Description: Ferrule style high speed fuses with and without indicating striker. Dimensions: See dimensions illustration. Ratings: Volts: — 690Vac (IEC) — 700Vac (UL) FWP with — 500Vac striker option. — 500Vdc (20-100A) Amps: — 20-100A IR: — 200kA RMS Sym. — 50kA @ 500Vdc Agency Information: CE, UL Recognition JFHR2.E91958, CSA Component Acceptance file Class 1422-30, 1422-90 (53787) The total clearing I t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I2t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (rms). 2 1.4 1.2 1.0 0.9 0.8 0.7 0.6 5 4 Eg 200 300 400 500 0.4 Eg 300 400 500 Dimensions - mm (in) Without Striker 58.0 (2.283") Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp, is given as a function of the RMS load current, Ib, in % of the rated current. 1.0 Kp 0.8 0.6 0.5 0.4 0.3 0.2 Ib 0.1 30 40 50 60 70 80 90 100% 22.2 (0.875") 600 700 Catalog Numbers Without Striker FWP-20A22F FWP-25A22F FWP-32A22F FWP-40A22F FWP-50A22F FWP-63A22F FWP-80A22F FWP-100A22F With Striker FWP-20A22FI FWP-25A22FI FWP-32A22FI FWP-40A22FI FWP-50A22FI FWP-63A22FI FWP-80A22FI FWP-100A22FI Size 22 x 58mm (7⁄8" x 29⁄32") 22 x 58mm (7⁄8" x 29⁄32") Electrical Characteristics I2t (A2 Sec) Minimum Clearing At Melting Rated Voltage Watts Loss 20 25 32 40 50 63 80 100* 19.0 34.0 53.5 68 135 280 600 1100 260 410 605 750 1600 3080 6600 12500 5 6 8 9 9.5 11 13.5 16 20 25 32 40 50 63 80 100* 19.0 34.0 53.5 68 135 280 600 1100 260 410 605 750 1600 3080 6600 12500 5 6 8 9 9.5 11 13.5 16 Rated Current RMS-Amps *IEC/UL Voltage rating 690/700 15.0 (0.591") With Striker 66 (2.598") 58 (2.283") • • • • Features and Benefits Excellent cycling capability and DC performance Low arc voltage and low energy let-through (I2t) Low watts loss in a compact size Used with finger-safe holders/blocks • • • • Typical Applications DC Common bus DC Drives Power converters/rectifiers Reduced voltage starters 16 (0.630" 22.2 (0.874") Data Sheet: 720026 236 700 Catalog Numbers 0.5 5 (0.197") 600 Power Losses K 0.3 200 UL 3 Electrical Characteristics Total Clearing I2t 1.4 1.2 103 9 8 7 6 For product data sheets, visit www.cooperbussmann.com/DatasheetsEle High Speed Fuses Ferrule — FWP 690V/700V (IEC/UL): 20-100A, Striker Optional Without Striker FWP 20-100A: 660V/700V (22 x 58mm) Time-Current Curve 104 6 4 2 103 6 4 2 FWP-50A22F FWP-63A22F FWP-80A22F FWP-100A22F 102 6 4 Virtual Pre-Arcing Time In Seconds 2 101 6 4 2 10 0 6 4 FWP-20A22F FWP-25A22F FWP-32A22F FWP-40A22F 2 10–1 6 4 2 10–2 6 4 2 10–3 6 4 2 2 101 4 6 8 2 102 4 6 8 High Speed Fuses 10–4 103 Prospective Current In Amps RMS Peak Let-Through Curve 104 FWP-100A22F FWP-80A22F 6 FWP-63A22F Peak Let-Through Current 4 FWP-50A22F 2 103 6 FWP-40A22F FWP-32A22F 4 FWP-25A22F FWP-20A22F 2 102 102 2 4 6 103 2 4 6 104 2 4 6 105 2 Prospective Short-Circuit Current Symmetrical RMS Data Sheet: 35785291 For product data sheets, visit www.cooperbussmann.com/DatasheetsEle 237